power optimizer - d3g1qce46u5dao.cloudfront.net

POWER OPTIMIZER Power Optimizer for North America P730 / P800p / P850 PV power optimization at the module-level The most cost effective solution for commercial and large field installations Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Balance of System cost reducon; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible Fast installaon with a single bolt Advanced maintenance with module-level monitoring Module-level shutdown for installer and firefighter safety Compliant with arc fault protecon and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Use with two PV modules connected in series or in parallel www.solaredge.us

Upload: others

Post on 26-Nov-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: POWER OPTIMIZER - d3g1qce46u5dao.cloudfront.net

POW

ER O

PTIM

IZER

Power Optimizerfor North America P730 / P800p / P850

PV power optimization at the module-level The most cost effective solution for commercial and large field installations SpecificallydesignedtoworkwithSolarEdgeinverters Upto25%moreenergy Superiorefficiency(99.5%) BalanceofSystemcostreduction;50%lesscables,fusesandcombinerboxes,

over2xlongerstringlengthspossible Fastinstallationwithasinglebolt Advancedmaintenancewithmodule-levelmonitoring Module-levelshutdownforinstallerandfirefightersafety CompliantwitharcfaultprotectionandrapidshutdownNECrequirements(wheninstalledaspartoftheSolarEdgesystem) UsewithtwoPVmodulesconnectedinseriesorinparallel

www.solaredge.us

Page 2: POWER OPTIMIZER - d3g1qce46u5dao.cloudfront.net

Power Optimizer for North America P730 / P800p / P850

PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) THREE PHASE 208V THREE PHASE 480VCompatiblePowerOptimizers P730(5) P800p,P850(5) P730 P800p,P850

MinimumStringLengthPowerOptimizers 8 13

PVModules 16 26

MaximumStringLengthPowerOptimizers 30 30

PVModules 60 60MaximumPowerperString 6000(6) 7200 12750(7) 15300 WParallelStringsofDifferentLengthsorOrientations Yes

Optimizer model(typical module compatibility)

P730 (for 2 x high power 72-cell PV modules)

P800p(for parallel connection of 2x 96-cell 5’’

PV modules)

P850*(for 2x high power or bi-facial

modules)INPUTRatedInputDCPower(1) 730 800 850 WAbsoluteMaximumInputVoltage(Vocatlowesttemperature) 125 83 120 Vdc

MPPTOperatingRange 12.5-105 12.5-83 12.5-105 VdcMaximumShortCircuitCurrent(Isc) 11 14 12.5 AdcMaximumDCInputCurrent 13.75 17.5 15.63 AdcMaximumEfficiency 99.5 %WeightedEfficiency 98.6 %OvervoltageCategory IIOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)MaximumOutputCurrent 15 18 AdcMaximumOutputVoltage 85 VdcOUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutputVoltageperPowerOptimizer 1±0.1 VdcSTANDARD COMPLIANCEEMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3Safety IEC62109-1(classIIsafety),UL1741Material UL-94(5-VA),UVResistantRoHS YesINSTALLATION SPECIFICATIONS CompatibleSolarEdgeInverters ThreephaseinvertersMaximumAllowedSystemVoltage 1000 Vdc

Dimensions(WxLxH) 128x152x50/5x5.97x1.96 128x158x59/5x6.22x2.32

128x152x59/5x5.97x2.32

mm/in

Weight(includingcables) 1064/2.34 1090/2.4 1064/2.34 gr/lbInputConnector MC4CompatibleOutputWireType/Connector DoubleInsulated;MC4CompatibleOutputWireLength 2.1/6.9 1.8/5.9 2.1/6.9 m/ftOperatingTemperatureRange(2) -40-+85/-40-+185 ˚C/˚FProtectionRating IP68/NEMA6PRelativeHumidity 0-100 %

(3)P800pandP850canbemixedinonestring.ItisnotallowedtomixP730withP800p/P850inonestringortomixP730/P800p/P850withP300/P320/P400/P405inonestring.(4)InacaseofoddnumberofPVmodulesinonestringitisallowedtoinstalloneP730/P800p/P850poweroptimizerconnectedtoonePVmodule.WhenconnectingasinglemoduletotheP800psealtheunused

inputconnectorswiththesuppliedpairofseals.(5)P730/P800p/P850designwiththreephase208Vinvertersislimited.UsetheSolarEdgeSiteDesignerforverification.(6)ForSE14.4KUS/SE43.2KUS:Itisallowedtoinstallupto6,500Wperstringwhen3stringsareconnectedtotheinverter(3stringsperunitforSE43.2KUS)andwhenthemaximumpowerdifferencebetweenthe

stringsisupto1,000W.(7)ForSE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS:Itisallowedtoinstallupto15,000Wperstringwhen3stringsareconnectedtotheinverter(3stringsperunitforSE66.6KUS/SE100KUS)andwhenthemaximum

powerdifferencebetweenthestringsisupto2,000W.*P850replacedtheP800s;theycanbeusedinterchangeablyandcanbeconnectedinthesamestring.

(1)RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.(2)Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingApplicationNoteformoredetails.

© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein

are trademarks of their respective owners. Date: 07/2018/V01/ENG NA. Subject to change without notice.