powerful operation & high...
TRANSCRIPT
N50∙N100∙N300∙N500∙N5000 Series
POWERFUL OPERATION & HIGH PERFORMANCE
Hyundai N-Series inverters with characteristics of digital control
and open network communication are newly developed products.
The compact Hyundai N-Series inverters, produced by the
state-of-the-art equipment, cover micro to high voltage large
capacity. They are new generation products meeting the
customers’ needs.
Hyundai Heavy Industries realizes thesatisfaction of customer with its bestproducts.
HYUNDAI
N50 Series ∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 06
N100 Series ∙∙∙∙∙∙∙∙∙∙∙∙ 08
N300 Series ∙∙∙∙∙∙∙∙∙∙∙∙∙ 10
N300-P Series ∙∙∙∙∙∙∙∙∙∙∙ 12
N500 Series∙∙∙∙∙∙∙∙∙∙∙∙∙ 14
N5000 Series∙∙∙∙∙∙∙∙∙∙∙∙ 16
C o n t e n t s
EconomicalEfficiency
HighReliability
Convenience
Suppleness
HighFunction
Versatility
We build a better future!
H Y U N D A I I N V E R T E R h i R U N N - S e r i e sH Y U N D A I I N V E R T E R h i R U N N - S e r i e s
N500
N300
N100
N50
N5000
HHI will realize customer satisfaction with its new
hiRUN N-Series04
Features
Fan, Pump, Conveyor,Wood working machine
Conveyor, Treadmill,Washing machine,Waste heat recoveryequipment, Automaticdoor, Extruder
3� 200V : 0.4 ~ 7.5kW
3� 400V : 0.4 ~ 7.5kW
1� 220V : 0.75 ~ 2.2kW
3� 200V : 5.5 ~ 55kW
3� 400V : 5.5 ~ 132kW
3� 200V : 5.5 ~ 75kW
3� 400V : 5.5 ~ 160kW
3� 400V : 160 ~ 350kW
3� 400V : 200 ~ 380kW
3� 3.3kV : 155 ~ 1940kW
3� 6.6kV : 330 ~ 3930kW
N300
(High Performance
Vector)
N300-P
(Fan, Pump)
N500
(Medium, Large
Capacity Vector)
N500-P
(Medium, Large
Capacity)
N5000
(High Voltage Large
Capacity Vector
Voltage Type)
N100
(Small Vector)
N50
(Single Phase
Vector)
�High torque with sensorless vectorcontrol
�MMI using RS485�Auto tuning�Compact size
�Compact size�High starting torque�Various operation methods�Easy maintenance
�Compact size�Powerful operation with improved
sensorless vector technology�Multi motor operation
�Automatic energy saving�Easy maintenance�User friendly interface�Low noised circuit
�Convenient operator(LCD)�Compact size�Trip tracting data save
�Energy saving
�Compact size
�Trip tracting data save
�High effiency�Low total harmonic distortion�Easy maintenance�Limitless distance between motor
and inverter�One touch screen digital operator
(5″color LCD)�Easy to use
Hoist, Crane, Extpuder,Machine tool, Parkingmachine, Textilemachine
Fan, Pump, Blower
Fan, Pump, BlowerN5000
N500
Fan, Pump, Conveyor
Fan, Pump, Blower
N300
N100
As general manufacturer of inverter in Korea, HHI will solve the customers’ problems easily with
its inverter varying from 0.4kW to 4000kW
Series Model Capacity Application
N50
05HYUNDAI INVERTER
Small SizeInverter
MediumCapacityInverter
LargeCapacityInverter
Features
�Vector inverter for single phasing input only
- High torque of 200% or greater at speeds as low as 1 Hz during starting
and operation.
�Realize triples driving by adding current suppression
- Stable operation even under the instantaneous impact load and overload
is realized through the addition of over-current level adjusting function.
- Maintain constant speed even at the time of sudden load change by rapid
speed restoration characteristics.
- Applicable to the transfer machine, treadmill, industrial washing machine
due to its function of momentary current suppression.
�Possible to select various operation method
- It is possible to select the operation method of either RS485
communication driving or analog signal driving for the user’s convenience.
�Compact size for easy installation
- Reduction in cubic volume, 52% compare to the N100 series.
�Develop optional product for user convenience
- DOP05 : Economical remote operator, Operation & display function
SeriesSeries
hiRUN N-Series
[ Single Phase Vector Inverter ]
06
RS485Communication
AnalogSignal �
07HYUNDAI INVERTER
Model
Applicable motor capacity (kW)
Rated output current (A)
Rated output capacity (kVA)
Rated output voltage (V)
Maximum output frequency (Hz)
Voltage / frequency
Power conditions
PWM method
Control method
Output frequency range
V/F characteristics
Overload rating
Starting torque
Torque boost
Acceleration/deceleration time setting
Acceleration/deceleration pattern
Current stall prevention operation level
Voltage stall prevention operation level
Analog frequency setting
Protective functions
Ambient temperature
Ambient humidity
Storage temperature
Installation area
Altitude and vibration
Cooling method
International directive compliance
N50-007SF
0.75
5.0
1.9
3-phase, 200~230 V
400 Hz
Single phase, 200~230Vac, 50/60 Hz
Voltage: ±10% / frequency: ±5%
Space vector PWM
V/F control, sensorless vector control
0.1 ~ 400 Hz
V/F free-setting (30~400 Hz of base frequency), constant torque and reduced
torque patten selectable
150% of rated current for 1 minute
More than 200% (at 1 Hz)
Manual torque boost can be set between 0~50%
0.1~3000 sec
Linear, S-curve, U-curve
Operating current level setting possible (20~200%), enable/disable selection
Operating current level constant, enable/disable selection
DC 0~10 V / 4~20 mA
Over current protection, under-voltage error, output short circuit, overland shut-off
(electronic thermal), ground fault, extermal trip, communition error, EEPROM error
-10~40 ℃ (no freezing)
90% RH or less (non-condensing)
-20~60 ℃ (short-term temperature during transport)
Indoors without corrosive gases, flammable gases, oil mist or dust
Maximum 1000m or less above sea level, 5.9 m/s2 or less
Forced cooling
CE & UL/cUL
N50-015SF
1.5
7.0
3.0
N50-022SF
2.2
11.0
4.2
Out
put
Inpu
tC
ontr
ol c
hara
cter
istic
Envi
ronm
ent
N50 Series Type
Motor (kW)
Single-phase 200 V
0.75 1.5 2.2
Model W D H
007SF
015SF, 022SF
80
95
Unit : mm
142
142
135
135
h i R U N N - S e r i e s
Standard Specification
Dimension
Features
Series
hiRUN N-Series
Series
�Advance sensorless vector control function
- Realize smooth driving without motor vibration and high precise driving with
no effect of changing load.
- Show high torque of 200% or greater at speeds as low as 0.5Hz during
starting and operation.
�Strengthening auto-tuning function
- Automatically measure motor parameters.
- Realize optimal motor control without torque dropping and speed fluctuation.
- Realize precise driving without inconvenience of user and measure motor
parameters manually.
�Strengthening the PID control function
- Strengthening the speed control program for controlling flux, temperature,
pressure and so forth.
- Apply to high precision systems by high speed responsibility.
�Realize tripless driving by adding current suppression
- Realize stable driving at instant impact load and overload by adding
over-current level adjusting function.
- Maintain constant speed on changing load suddenly by rapidity speed
restoration characteristics.
- Widely apply transfer machine, treadmill, industrial washing machine and so
forth by momentary current suppressing.
�MMI function using RS485 communication (HIMS 2000)
- Built-in RS485 communication standard using Modbus protocol possible
flexible application for various FA system, on remote driving at upper system
and easy monitoring the status of driving.
- Realize remote motor control drive using exclusive MMI program.
08
[ Small Size Vector Inverter ]
Dimension
N100 Series Type
Standard Specification
Motor (kW)
3-phase 200 V
3-phase 400 V
0.4 0.75 1.5 2.2 3.7 5.5 7.5
Option
�Remote Operator : NOP1 (Copy Unit) / DOP1 (Economic)- Cable : 1.5m (Nop1-1A) / 3.0m (Nop1-3A)
�Noise Filter (Input) - FT-20301S-A (200 V, 0.4~5.5 kW) - FT-20401S-A (200 V, 7.5 kW) - FT-40201S-A (400 V, 0.4~7.5 kW)
W ◀ ◀
H
▲
▲
D◀ ◀
h i R U N N - S e r i e s
�SINK/SOURCE type signal selectable- Many types of programmable controllers are easily connected.
�Global products- Observe EN standard by attaching EMC filter (option)- Obtain CE Standard, UL, cUL
�Compact size for easy to install- Reduction in cubic volume 52% compare to the J100 series.
�Develop option product for user convenience- Digital Operator(operation and display)- Remote Operator(read and copy function)- EMI/EMC filter by EN standard
09HYUNDAI INVERTER
Model W D H
N100-004LF, 007LF, 004HF
N100-015LF, 022LF, 007HF, 015HF
N100-037LF, 022HF, 037HF
N100-055LF/HF, 075LF/HF
N100-037HFK1.2/055HFK1.2/075HFK1.2
115
115
150
185
185
135
155
155
186.5
186.5
130
130
130
250
250
Unit : mm
3-phase, 380 ~ 460 VAC
0.1 ~ 400 Hz
3-phase, 380 ~ 460 VAC
50 / 60 Hz (±5%)
ASIPM
Space vector PWM control
200%, 0.5 Hz
150%, 1 min
DC0~5 V, DC0~10 V, DC4~20 mA, 0~1 kΪ
Model
200 V Class 400 V Class
Applicable motor capacity (kW)
Rated output current (A)
Rated output capacity (kVA)
Rated output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg) 1.2 1.2 1.5 1.5 2 5.3 5.3 1.2 1.5 1.5 2 2 5.3 5.3
0.1 ~ 400 Hz
3-phase, 200 ~ 230 VAC
50 / 60 Hz (±5%)
ASIPM
Space vector PWM control
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 5 V, DC 0 ~ 10 V, DC 4 ~ 20 mA, 0 ~ 1 kΪ
3-phase, 200 ~ 230 VAC
N100-004LF
0.4
3.0
1.1
N100-007LF
0.75
5.0
1.9
N100-015LF
1.5
7.0
3.0
N100-022LF
2.2
11.0
4.2
N100-037LF
3.7
17.0
6.1
N100-055LF
5.5
24.0
9.1
N100-075LF
7.5
32.0
12.2
N100-004HF
0.4
1.8
1.1
N100-007HF
0.75
3.4
1.9
N100-015HF
1.5
4.8
3.0
N100-022HF
2.2
7.2
4.2
N100-037HF
3.7
9.2
6.1
N100-055HF
5.5
12.0
9.1
N100-075HF
7.5
16.0
12.2Ratedoutput
Ratedinput
PIM PIM
10
Features
Series
N300 Series Type
Motor (kW)
3-phase 200 V
3-phase 400 V
5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132
Series
hiRUN N-Series
[ Powerful Vector Inverter (VFD or AC Drive) ]
�Powerful operation with advanced sensorless vector control- High starting torque of 200% or greater at 0.5 Hz- High torque of 50% at approximately 0 Hz when the inverter drives a smaller
motor by one frame size
�Continuous 100% torque within 6~60 Hz for general motor- Unnecessary dedicated motor
�High torque multi-motor operation- Different motor constants up to 3
�Minimal rotational fluctuation at low speed- Enhanced process stability and precision
�On-line / Off-line autotuning
�On-line auto tuning for motor constant check based on thetemperature
�Fan On / Off selectable- Fan off during stopping for less noise and longer life
�Compact size / Easy to maintain- Easy to assemble / Disassembly like cartridge
�PID Control- Efficient continuous control for winder tension and unnecessary extra PI controller
�HIMS (Hyundai Inverter Management System) and variouscommunication protocol- DeviceNet, Profibus support (option)- Advanced monitoring funtion
11HYUNDAI INVERTER
Standard Specification (200 V Class)
Model
200 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055LF
5.5
24
8.1
3.5 5 5 12 12 12 20 30 30 50
N300-075LF
7.5
32
11
N300-110LF
11
46
15.9
N300-150LF
15
64
22.1
N300-185LF
18.5
76
26.3
N300-220LF
22
95
32.9
N300-300LF
30
121
41.9
N300-370LF
37
145
50.2
N300-450LF
45
182
63
N300-550LF
55
220
76.2
0.1 ~ 400 Hz
3-phase 200 ~ 240 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 200 ~ 240 VAC
Dimension
[ A-Type ]
[ B-Type ]
W ◀ ◀
H
▲
▲
D
▲
▲
W ◀ ◀
H
▲
▲
D
▲
▲
ModelType W D H
A
B
N300-055LF/HF
N300-075~110LF/HF
N300-150~220LF/HF
N300-300LF/HF
N300-370~450LF/HF, 550HF
N300-550LF
N300-750, 900HF
N300-1100, 1320HF
150
210
250
310
390
480
390
480
Unit : mm
140
170
190
195
250
250
270
270
255
260
390
540
550
700
700
740
Option
�Feedback board : N3 - FB�Digital input board : N3 - DG�Communication board (DeviceNet) : N3 - DN�Braking Regenerative Device (BRD Unit)�Input / Output AC Reactor
Ratedoutput
Standard Specification (400 V Class)
Model
400 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055HF
5.5
12
8.3
3.5 5 5 12 12 12 20 30 30 30 60 60 80 80
N300-075HF
7.5
16
11
N300-110HF
11
23
15.9
N300-150HF
15
32
22.1
N300-185HF
18.5
38
26.3
N300-220HF
22
48
33.2
N300-300HF
30
58
40.1
N300-370HF
37
75
51.9
N300-450HF
45
90
62.3
N300-550HF
55
110
76
N300-750HF
75
149
103
N300-900HF
90
176
122
N300-1100HF
110
217
150
N300-1320HF
132
260
180
0.1 ~ 400 Hz
3-phase 380 ~ 480 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 380 ~ 480 VACRatedoutput
Ratedinput
Ratedinput
h i R U N N - S e r i e s
12
Applied Load
[ Fan, Pump Dedicated Inverter ]
�2 x Load such as fan, pump, blower, etc.
Features
�High energy saving-automatic running mode
- Voltage control application to run motor with a minimum current - installed
energy saving operation mode as standard
�Easy to maintenance
- Easy to replace cooling fan and smooth capacitor and easy to reconnect for
detachable control board
�Compact size
- Thermal analysis and vibration analysis making optimization of components
position and miniaturization
�User-friendly operational environment
- User group function allows customers to select menus
�Various communication protocol
�Lower main board and power board noise
- Lower the effect to the sensor and paralleled devices
SeriesSeries
hiRUN N-Series
ModelType
[ A-Type ]
W D H
A
B
N300-055~075LFP/HFP
N300-110~150LFP/HFP
N300-185~300LFP/HFP
N300-370LFP/HFP
N300-450~550LFP/HFP, 750HFP
N300-750LFP
N300-900~1100HFP
N300-1320~1600HFP
150
210
250
310
390
480
390
480
Unit : mm
140
170
190
195
250
250
270
270
255
260
390
540
550
700
700
740
W ◀ ◀
H
▲
▲
D
▲
▲
[ B-Type ]
W ◀ ◀
H
▲
▲
D
▲
▲
Dimension
13HYUNDAI INVERTER
N300-P Series Type
Motor (kW)
3-phase 200 V
3-phase 400 V
5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160
Standard Specification (400 V Class)
Model400 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055HFP
5.5
11
7.6
3.5 3.5 5 5 12 12 12 20 30 30 30 60 60 80 80
N300-075HFP
7.5
15
10.4
N300-110HFP
11
22
15.2
N300-150HFP
15
29
20
N300-185HFP
18.5
37
25.6
N300-220HFP
22
43
29.7
N300-300HFP
30
57
39.4
N300-370HFP
37
70
48.4
N300-450HFP
45
85
58.8
N300-550HFP
55
105
72.7
N300-750HFP
75
135
93.5
N300-900HFP
90
160
110.8
N300-1100HFP
110
195
135
N300-1320HFP
132
230
159.3
0.1 ~ 400 Hz
3-phase 380 ~ 480 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
150%, 0.5 Hz
120%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 380 ~ 480 VAC
Standard Specification (200 V Class)
Model
200 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055LFP
5.5
22
7.6
3.5 3.5 5 5 12 12 12 20 30 30 50
N300-075LFP
7.5
30
10.4
N300-110LFP
11
44
15.2
N300-150LFP
15
58
20
N300-185LFP
18.5
73
25.2
N300-220LFP
22
85
29.4
N300-300LFP
30
113
39.1
N300-370LFP
37
140
48.4
N300-450LFP
45
169
58.5
N300-550LFP
55
210
72.7
N300-750LFP
75
270
93.5
0.1 ~ 400 Hz
3-phase 200 ~ 240 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
150%, 0.5 Hz
120%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 200 ~ 240 VAC
N300-1600HFP
160
295
204
Ratedoutput
Ratedoutput
Ratedinput
Ratedinput
h i R U N N - S e r i e s
14
Features
�Minimized size
- Economical installation space
�LCD display operator installation
- Parameter download function
- Proper words on the display to improve readability
� Internal PID control function
- Control PID value such as flow, velocity, etc. by internal PID control function
�More convenient user interface
- MMI using RS-485 communication
- Parameter values display & remote setting function
- Pretest by simulation function according to the load classification
� Improved troubleshooting
- Trace date save function for the specified time during trip to advance
maintenance function
SeriesSeries
hiRUN N-Series
[ Medium Voltage Vector Inverter ]
15HYUNDAI INVERTER
Standard Specification (400 V Class)
Model
Standard Fan, Pump only
Motor capacity (kW)
Rated current (A)
Overload capacity
Rated output voltage
Output voltage method
Control method
Starting torque
Output frequency range
Digital I/O
Analog I/O
Analog input command
Weight (kg)
N500-1600HF
160
308
N500-2200HF
220
424
N500-2800HF
280
525
N500-3500HF
350
656
N500-2000HFP
200
385
N500-2800HFP
280
525
N500-3200HFP
320
616
N500-3800HFP
380
732
3-phase 380 ~ 480 V (±10%), 50/60 Hz (Complying with input voltage)
Space vector PWM
V/F control, seneorless vector control, sensored vector control
200%, 0.5 Hz
0.1 ~ 400 Hz
Multi-function digital input 8 channel, multi-function open collector output 5 channel,
multi-function C contact output 2 channel
Voltage / current output 2 channel, pulse output 1 channel
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
150%, 1 min 120%, 1 min
Dimension
Model W H D
N500-1600HF
N500-2200HF
N500-2000HFP
N500-2800HFP
N500-2800HF
N500-3500HF
N500-3200HFP
N500-3800HFP
N500-2200HFK
620
620
620
620
800
800
800
800
620
Unit : mm
750
750
750
750
1150
1150
1150
1150
930
380
380
380
380
380
380
380
380
380
Ratedoutput
180 180 215 215 180 180 215 215
N500 Series Type
Motor(kW)
3-phase 400 VStandard
Fan, Pump only
160 200 220 280 320 350 380
3-phase 400 V
h i R U N N - S e r i e s
Features
�Environment-friendly system to meet harmonic waves rule
(IEEE519-1992) by serialized multiplex drive
�High power factor and electric conversion efficiency
�High efficient operation by sensorless vector control
�Economic installation by slimming
�Easy maintenance by modularization
�Easy operation by one touch screen digital operator
�Remote console on user-friendly windows OS
- Motor input is transferred from VFD to line voltage.- This option is necessary to do maintenance without line stopping.
�CELL Bypass- In case of failure of inverter cell unit, inverter can continuously operate with
duration.
�Redundancy of system controller- N5000 has master and slave controller.- Continuous operation is possible under any failure of master controller.
�Redundancy of system control power unit- Continuous operation is possible in spite of AC or DC control power failure,
without UPS.
�Automatic restarting function- After input line power recovered, the coasting motor can automatically restart
smoothly.
SeriesSeries
[ High Voltage Mega Capacity Vector Inverter (Voltage Type) ]
16 hiRUN N-Series
Model Name Indication
N5000 - ���� �
Applicable Motor Capacity (kW)
Voltage Class : L (3.0/3.3 kV)H (6.0/6.6 kV)
Ex) 3300 V, 1500 kW : 1500L6600 V, 835 kW : 0835H
Synchronous Transfer Option
Trip Free Functions
h i R U N N - S e r i e s
17HYUNDAI INVERTER
Standard Specification
Dimension
Model W H� DN5000-0155LN5000-0245LN5000-0325LN5000-0410LN5000-0490LN5000-0620LN5000-0835LN5000-1040LN5000-1270LN5000-1500LN5000-1710LN5000-1940LN5000-0330HN5000-0495HN5000-0675HN5000-0835HN5000-1000HN5000-1270HN5000-1700HN5000-2130HN5000-2590HN5000-3020HN5000-3450HN5000-3930H
2400
2900
3400
3850
4200
5100
3100
3600
4600
5600
5800
7400
Unit : mm
2350
2350
2350
2350
2450
2450
2350
2350
2450
2350
2450
2450
1000
1000
1100
1200
1400
1400
1100
1100
1200
1200
1400
1400
2250
394
1940
4500
394
3930
2000
350
1710
4000
350
3450
1750
307
1500
3500
307
3020
1500
263
1270
3000
263
2590
1250
219
1040
2500
219
2130
1000
175
835
2000
175
1700
750
132
620
1500
132
1270
600
105
490
1200
105
1000
500
88
410
1000
88
835
400
70
325
800
70
675
300
53
245
600
53
495
3300 V 1)
6600 V 1)
3-phase 3300 V, 50/60 Hz or 3-phase 6600 V, 50/60 Hz
3 Phase 220 V or 440 V, 50 Hz or 60 Hz
Voltage : ±10%, Frequency : ±5%
50 or 60 Hz
120%, 60 sec
Approx. 95% or more at normal operating speed
Approx. 96% (Including transformer)
Sensorless vector control + Multilevel sinusoidal PWM
±0.5% of max. output frequency (Analog input)
Square torque load, constant torque load
0.1~3270 sec (Depend on GD2 of motor and load)
Restart after instantaneous power failure, operation possible at instantaneous input power failure
(0~83 ms, non-torque control), specific frequency evasion function, multiple Acc./Dcc. rate setting, soft stall
Current limit, over current, over voltage, over load, under voltage, grand fault, CPU error, cooling fan abnormal, control power abnormal
RS485/232/modbus/ethernet, profibus-DP (Option)
Color LCD graphic : color TFT touch screen 5″LCD
Start, stop, reset fault
Input : 4 channel (DC 0~10 V or DC 4~20 mA) Output : 4 channel (DC 0~10 V or DC 4~20 mA)
Input : 16 channel (Dry contact) Output : 8 channel (Dry contact : AC 250 V 5 A or DC 30 V 5 A)
Temperature class H, Dry type, tapping range ±5% for N5000 only
IP20 (IEC-529)
Free standing, free maintenance type, door handle key type
Air cooled by ventilation fans mounted on panel (IP40 without opening or closing of panel door)
Munsell No. 5Y 7/1
0~40 ℃
Max 85% (No condensation)
1000m above sea level or less
0.5 G or less at 10~50 Hz
Indoor
Fan, blower, pump, compressor, extruder, mixer, turbine generators etc.
Electrical performance : IEC Components : KS
Output
Control specifi-cation
Operationboard
Con-struction
Ambientconditions
Signal interface
Input
※ 1) As for non-standard voltage (3.0/4.16/6.0 kV) motor, please contact our company.2) HHI 4-pole standard induction motor
�Including the cooling fan on the panel
Voltage Class
3.3 kV output capacity (kVA)
Rated output current (A)
Motor power output (kW) 2)
Voltage Class
6.6 kV output capacity (kVA)
Rated output current (A)
Motor power output (kW) 2)
Main circuit
Control circuit
Tolerance
Output frequency (Hz)
Overload capacity
Power factor of main power supply
Efficiency
Control method
Frequency precision
Torque characteristics of load
Acceleration deceleration time
Main control functions
Main protective functions
Data transmission
Display
Method
Analog
Digital
Input transformer
Protection degree of enclosure
Panel construction
Cooling
Panel color
Ambient temperature
Humidity
Altifude
Vibration
Installation
Application
Standards
200
35
155
400
35
330
HH
IS-WC
-CE-A22- 03, 2007.10 D
esigned by ADPAR
K
www.hyundai-elec.com
Head Office 1 Jeonha-dong, Dong-gu, Ulsan, Korea TEL. 82-52-202-8101~8 FAX. 82-52-202-8100
Seoul 140-2, Gye-dong, Jongno-gu, Seoul, Korea (Sales & Marketing ) TEL. 82-2-746-7596, 7519 FAX. 82-2-746-8448
Orlando 3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A. Tel. 1-407-249-7350 Fax. 1-407-275-4940
London 2nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UKTel. 44-20-8741-0501 Fax. 44-20-8741-5620
Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-ku, Tokyo 100-0006, Japan Tel. 81-3-3212-2076, 3215-7159 Fax. 81-3-3211-2093
Dubai Room 6206, AI Bustan Centre AI Qusais P.O.Box 252458 Dubai, U.A.E.Tel. 971-4-263-9071 Fax. 971-4-263-9072
Sofia 1271, Sofia 41, Rojen Blvd. BulgariaTel. 359-2-803-3200 Fax. 359-2-803-3203
Yangzhong Lianzhong Avenue, Xinba Scientific and Technologic Zone, Yangzhong City, Jiangsu 212212, ChinaTel. 86-511-842-0666, 0500 Fax. 86-511-842-0668, 0231