powerlogic ® powerview software power management software for power meters --- internal sales &...
TRANSCRIPT
PowerLogic® PowerView SoftwarePower Management Software for Power Meters --- INTERNAL SALES & MKTG USE ONLY ---
Schneider Electric 2- Marketing - PowerView – December 2008
PowerLogic PowerView Software
●Competitively priced at $2850 (list) to drive PowerLogic power meter sales
●Ideally suited for new commercial/industrial energy conscious users requiring small initial investment for power monitoring
●Availability: July 2007
Schneider Electric 3- Marketing - PowerView – December 2008
Product Overview
●Compliments the PowerLogic power meter offer●Easy to use – 3 tab functionality
● Setup
● Real time displays
● Report Builder
●Able to install and begin monitoring within 1 hour
●PowerLogic system expertise NOT required to sell!!!!
Schneider Electric 4- Marketing - PowerView – December 2008
Sales Tools
●Brochure Doc#3000BR0706●Online Flash Demo (or download Flash to PC)●Customer Presentation
(Product Launch Workzone or Power Management Tech Library)
Schneider Electric 5- Marketing - PowerView – December 2008
Supported Devices
●The list of Supported Devices are:●High Density Meters
●Power Meter 710,750
●Power Meter 810, 820, 850
●ION 6200
●Future device type adaptations will be added as Product Evolutions
●Maximum number of Devices:●The maximum number of devices for this software application is 32.
PowerView Software Product Feature Overview
Schneider Electric 7- Marketing - PowerView – December 2008
Operation: Setup and Communications to devices
●Device Connections● Automatic Detection (Auto discovery of networked devices)
●After assigning a valid IP address, the system will poll the connected network for supported devices
● Manual connections●End users have option to manually add/delete devices
● Automatically names devices●User can change the name
●Communications ● Types (Modbus)
●TCP/IP●RS-485 Serial ●Troubleshooting devices with communications errors marked/highlighted in red on the device list. Right click on device and restore communications.
Schneider Electric 8- Marketing - PowerView – December 2008
Auto Discovery of networked devices
Schneider Electric 9- Marketing - PowerView – December 2008
Data Logging
●Onboard Data Logging:●Power Meter 820/850 perform onboard data logging
●PowerView Software automatically data retrieves onboard files every 4 hours from Power Meter 800s
●The onboard data log interval is set in PMCU (setup utility)
●PC-based Data Logging:●PC-based data logging is collected by PowerView for the high density meters and Series 700 Power Meters
●Default logging interval is 15 minutes and can be changed by the end user
●The measurements that are PC based data logged are a fixed set of parameters that cannot be changed
●Quantities (measurements) Logged:●The measurements logged will be current, voltage, power, power factor, energy, demand power, demand current, and total harmonic distortion (THD).
Schneider Electric 10- Marketing - PowerView – December 2008
Database Management
●Database Backups:●The option to backup the database will be available.
●Database Restores:●The option to restore the database will be available.
●Historical Database Management:●The Historical database will be maintained below 2GB in size. Data will be deleted from the Historical database as first in – first out (FIFO) to prevent growth over 2GB. Deleted Historical data is not retained.
●An indication will be provided when the database goes into FIFO mode
●Upgrade options●The PowerView Software databases will be compatible with SMSPE (requires SqD Engineering Services to migrate customer from PowerView to SMSPE)
Schneider Electric 11- Marketing - PowerView – December 2008
Real Time Display – Summary View
Schneider Electric 12- Marketing - PowerView – December 2008
Real Time Display – Device View
Schneider Electric 13- Marketing - PowerView – December 2008
Report Builder
● Basic Queries:● Device(s) + Measurement(s)+ time range= Output (trends, charts, tables)● Both PC and Onboard (PM8’s) data available in database.
● Pre-configured Queries:● Focused on providing end user with historical information on their Electrical Energy
usage and power demand.●Energy usage for last day, week, month●Energy TOU (Time of Use) or Energy Bands outputs
● Support for Time of Use Metering includes.●Defining up to 3 schedules●Each Schedule can contain
– -> up to 10 periods (bands) for energy accumulation– -> Supports weekends, special days, holidays
● Reports Viewer:● End user will be expected to have Microsoft Excel to view reports.
●All costing and other calculations (eg. Terrifications, rates) can be done manually by the customer in Excel.
Schneider Electric 14- Marketing - PowerView – December 2008
Report Builder
Schneider Electric 15- Marketing - PowerView – December 2008
General Report Example
Schneider Electric 16- Marketing - PowerView – December 2008
Export the Data
Schneider Electric 17- Marketing - PowerView – December 2008
Time of Use Setup
Schneider Electric 18- Marketing - PowerView – December 2008
Time of Use Setup
Schneider Electric 19- Marketing - PowerView – December 2008
Time of Use Setup
Schneider Electric 20- Marketing - PowerView – December 2008
Time of Use Setup
Schneider Electric 21- Marketing - PowerView – December 2008
Time of Use Setup
Schneider Electric 22- Marketing - PowerView – December 2008
Appendix A – Data Logging per Device
Schneider Electric 23- Marketing - PowerView – December 2008
Appendix B – Comparison Chart PowerView vs. SMS 4.0
Schneider Electric 24- Marketing - PowerView – December 2008
Appendix B – Comparison Chart PowerView vs. SMS 4.0
Part 1:
POWERVIEW
Schneider Electric 25- Marketing - PowerView – December 2008
Appendix B – Comparison Chart PowerView vs. SMS 4.0
Part 2:
(3) Database only , to SMSPE, by qualified personnel
X
Schneider Electric 26- Marketing - PowerView – December 2008
Appendix B – Comparison Chart PowerView vs. SMS 4.0
Part 3:
(4) PV: Automated/ SMS v4: Automated/manual(5) PV: 32 devices, support PM9, PM2, PM500, PM7, PM810, PM820, PM850, PM9, ION6200, Micrologic P & H, Toro MC. SMSv4: DL (32 devices), SE, PE (unlimited)