What would you do?
Objective
Terminal Learning Objective: Perform the functions of the ECP
Operator Control Station systems
• Action: Perform the functions of the Control Station computer.
• Conditions: Given an operator’s manual, all applicable handouts,
in a classroom environment, and hands-on-instruction.
• Standard: Perform all tasks on the operator task list with less than
20% errors requiring remediation on the performance evaluation.
3
Power-On Procedures
The ECP Control Station Server requires a minimum of 6 minutes to boot up prior to turning on the ECP Operator Station. Therefore, the first step in operating the ECP equipment is to power on the ECP CS Server.
Power-on ECP Control Station Server
Step 1: Ensure the ECP CS Server is plugged in to a viable 30 amp 120 VAC power source
Step 2: Push and hold thePower button until the Uninterruptable Power Supply (UPS) turns on.
5
Power-on ECP Control Station Server
Note: When the Uninterruptable Power Supply or UPS is ONthere are 3 solid lights.
Once the UPS is on, the Video Encoder will turn on automatically.
6
Power-on ECP Control Station Server
Step 3: Next, turn on the IOLAN device server by flipping the toggle switch to the ON position.
7
Power-on ECP Control Station Server
Step 4: Open the server dust screen door by turning the knob counter clockwise and pulling open the door. Next, press the power button on the right hand side of the server and close and lock the dust screen door by turning the knob clockwise.
8
* Wait 6 minutes before turning on Operator Station. Server needs time to configure.
Power-on ECP Control Station
Step 1: Push and hold the Power button until the UPS turns on.
Step 2: Unlock screws and slide tray out until it locks with an audible click.
9
1
2
Perform login procedures
Step 1: Log-in to
JBC2S using the
following user name
and password.
Username: Operator
Password: Operator
10
Menu Options
The JBC2S Menu Options
are located at the top left of
the JBC2S Screen.
The Menu Options are –
• File
• View
• Maps
• Share
• Paths
• Tools
• Help
11
Knowledge Check
How do you obtain local maps for JBC2S?
Local maps must be loaded into the software.
Maps Menu
The Maps menu displays:
1. Area of Interest
• Go To – Allows the user to
go to the preset Area of
Interest (AOI)
• Set Current - Allows the
user to set Area of Interest
(AOI)
13
What information can be shared under the Share menu?
Knowledge Check
Map data such as graphics, targets or zones.
What tool allows a user to enter coordinates in one of 6 JBC2S formats and then read them in any of the other formats?
Coordinate Converter.
Peripheral Actions
Mouse actions that are
available to the ECP operator
within the JBC2S system
include but are not limited to
the following:
• Mouse Hover
• Left Single Click
• Left Double Click
• Scroll Wheel Turn
• Scroll Wheel Click
• Right Single Click
15
Knowledge Check
What is hydraulic drift?
Hydraulic drift can occur over time meaning the arm will start to lower. It will send an open indication (in red) to JBC2S. The operator will have to close periodically by sending close command to the barrier. If barrier needs to remain up there are locking pins on either side of the barrier.
Peripheral Operations - Camera
Track PTZ camera with
peripheral.
1. Scrolling with the live
video window selected –
zooms the video in and out.
Note: If the camera can be
zoomed, this is an optical
zoom. Otherwise, it is a
digital zoom.
17
Peripheral Operations - Joystick
Using the joystick to track a
PTZ camera:
1. Camera Pan – tilting to
the right causes the
camera to pan right.
Tilting to the left causes
the camera to pan left.
18
Pan Left Pan Right
E-STOP ALL
The E-STOP ALL
function is for emergency
situations such as a barrier
about to cause harm to
personnel or equipment.
This button, when clicked,
stops all barriers in their
current position or in the
case of the drop arm
barrier it will reverse
directions.
19
Delta Pop-Up Barrier Manual Operations
20
Step 1: Locate the Pop-Up
hydraulic pump unit (HPU)
for the barrier.
Step 2: Locate the barrier
plate manual hydraulic control
handle and hold it in the
forward position until the
barrier plate is completely
lowered. Place the handle
back in the forward position
once the barrier plate has been
completely lowered.