powerview3 − hmi module · 2014-07-30 · powerview3 activation code for visualization of detcon2...

6
Try the alternative. Call the nearest MOTORTECH sales partner for more information. REV.03/2014 MOTORTECH ENGINE INFORMATION MONITOR PowerView3 PowerView3 − HMI MODULE VISUALIZATION OF IGNITION AND DETONATION CONTROL

Upload: others

Post on 04-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

Try the alternative.Call the nearest MOTORTECH sales partner for more information. REV.03/2014

MOTORTECH ENGINE INFORMATION MONITORPowerView3

PowerView3 − HMI MODULEVISUALIZATION OF IGNITION AND DETONATION CONTROL

Page 2: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

PowerView3 – HMI Module

PowerView3isacompactandflexibleHMImodule(Human-Machine-Interface)forvisualizationandoperationofMOTORTECHsnewgenerationcontrolunits.Onmorethan25screens the 7” color display supports the full visualization of the most important operating data of ignition and detonation controlaswellastheadjustmentofvariousparameters.Errordiagnosticscanbeexecutedeasilyon-sitewithoutrequiringa laptop.Thetouchscreenguaranteesanintuitivenavigationthroughdifferentdisplaypagesandmenus.TherelevantoperatingdatacanbeeasilyrecordedandstoredviaUSBmassstoragedeviceorSDcard.Thevisualizationfunctionshavetobeactivated for every single device. Additional activations or firmware updates are possible at any time.

MOTORTECH ENGINE INFORMATION MONITORPowerView3

GeneralFeatures

• Visualizationofignitioncontrol,detonationcontrolandtemperaturemonitoring(availablesoon)viaCANbus

• Accesscontrol• DisplayofCANconnectionstatus• Severaldisplayconfigurations(language,date, displaycalibration,etc.)

• Forassemblyincontrolpanels• Dayandnightmode

DetonationControl(DetCon2/DetCon20)

Overview with status indication for• Analogoutputsignal• Knockingintensity• Stateofreduction

Fault message for• Lowspeed• Synchronizingpulse• Defectiveknocksensor

Display of trend data• Knockingintensity• Outputsignal

Displayofknockingintensity

IgnitionControl(MIC4/MIC5series)

Overview with status indication for• Pickupsignals• Activeschedule• Analogdisplayofenginespeed• Ignitiontiming• Sparkplugs(operatinghours)

Display of global ignition timing dependent on• Baseignitiontiming• Potentiometeradjustment• Analogcurrentandvoltageinput• Speedcurve

Displays the ignition of each cylinder• Ignitionvoltage• Misfires

Display of misfires• Primaryandsecondarysidedwiringerrors• Typeoferror(noconnection/shortcircuit)

Display and adjustment of energy• Sparkduration• Sparkintensity

Display and adjustment of firing angles and ignition energy

Self-testactivation

Warning,alarmanderrormessages

Page 3: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

MIC Overview

• Statusdisplays(pickup,ignitionoutputs,ignitionenabled,systemstatus,schedule)

• Displaysthecurrentenginespeed

• Showsthecurrentglobalignitiontimingin°crankshaft

• Displaysthepreviousoperatinghoursofthesparkplugs

• Displaystheestimatedignitionvoltageforeachindividualcylinder

• Displayofcurrentandpastmisfiresofeachindividual cylinder

Sample Screens – Visualization MIC4 / MIC5

• Displayofestimatedsecondaryvoltageofallselected cylinders

• Cylinderscanbedisplayedandhiddenindividually

• Zoomfunctionfordetailedviewofsecondaryvoltage

• Navigationwithinthetimeline

Ignition

SecondaryVoltage

Page 4: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

DetCon Overview

Sample Screens – Visualization DetCon2 / DetCon20

• Statusdisplays(engineknocking,activeloadreduction,emergencyshutdown,signalerrors)

• Displaystheanalogoutputsignalstrength

• Displaystheknockingintensityinpercent

• Displayofsensorerrors

KnockingIntensity

TrendKnockingIntensity

• Showstheknockingintensityprogressofallselected cylinders

• Cylinderscanbedisplayedandhiddenindividually

• Zoomfunctionfordetailedviewofknockingintensity

• Navigationwithinthetimeline

• Displayofknockingintensityforeachcylinder ·Green: Thedetonationcontroldoesnotregisterany excessiveknockingintensity ·Yellow:Detonationcontrolreducesknocking ·Red: Criticalenginestate

• Additionalstatusdisplayforsensorerrorsatthecylinder

Page 5: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

Part Numbers / How to Order for new Installations

P/N Description

06.05.085 PowerView3 – HMI module

06.05.086-F PowerView3 activation code for visualization of MIC4 / MIC5 data. Code has to be ordered separately with each PowerView3 HMI module. Factory activation will be done with delivery.

06.05.087-F PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module. Factory activation will be done with delivery.

Part Numbers / How to Order for Upgrades of installed PowerView3 HMI Modules

P/N Description

06.05.086-U PowerView3 activation code for visualization of MIC4 / MIC5 data. Only available for upgrade of an installed PowerView3 HMI module in the field. Activation will be done on-site.

06.05.087-U PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Only available for upgrade of an installed PowerView3 HMI module in the field. Activation will be done on-site.

Memory • MemorySDcardslot• USB2.0port

Communication Interfaces • Network:100Mbit/sEthernet(POE)• CANfieldbus:1xCAN(ISO/DIS119898)

Touchscreen• Colors:16bit(65.536colors)• Touchtechnology:resistive• Surfaceproperties:3H/anti-glare• Displaysize:7.0in./178.0mm• Resolution:WVGA(800x480pixels)

Housing• Metalparts:1.4016highqualitysteel,0.03in./0.75mm• Protectionrating:IP64(frontside)

Device Dimensions• Width:7.95in./202.0mm• Height:4.97in./126.2mm• Depth:1.16in./29.5mm• Weight:22oz/670g

Power Supply • Powersupply:Nom.24VDC±15%,max.10–30VDC• Powerconsumption:Typ.4.5W

Typical Environmental Conditions• Storagetemperature:-4°Fto158°F/-20°Cto+70°C• Operationtemperature:-32°Fto140°F/0°Cto+60°C• Relativehumidity:max.95%(withoutcondensation)

Technical Data

Page 6: PowerView3 − HMI MODULE · 2014-07-30 · PowerView3 activation code for visualization of DetCon2 / DetCon20 data. Code has to be ordered separately with each PowerView3 HMI module

Distributedby:

Office

Distributor

Headquarter

MOTORTECH GmbHHogrevestr.21-2329223CelleTelefon:+49514193990Telefax:[email protected]

MOTORTECH Americas, LLC1400DealersAvenue,SuiteANewOrleans,LA70123Telefon:+15043554212Telefax:[email protected]

P/N01.15.020-EN|MOTORTECHSalesFlyerPowerView3

COPYRIGHTThecopyrightforanymaterialusedintheMOTORTECHpublications is reserved. Any duplication or use of objects such as pictures or textsinotherelectronicsorprintedpublicationsisnotpermittedwithoutMOTORTECH´sagreement.

TRADEMARK INFORMATIONAllOEMnamesandpartnumbersshownareforreferencepurposeonly.Alltrademarks,logos,andsymbolsusedorshownintheMOTORTECHpublica-tionsareexclusiveobjectstotherightoftheir owners and are used for reference purpose only.

Regardlessofwhichpartoftheglobeweneedtotravelto.

Weknowthatthestakesarehigh,andthereforeweoutperformtheothers.Thatisbecausewewantevery-thingtorunsmoothlyatyoursite,everywhereandatany time.

Thisisentirelyinkeepingupwithourmotto:Letusdropeverythingandworkonyourproblem!

WhenThingsgethotourServiceTeamisatyourSitequickly.

DistributionpartnerforDENSOsparkplugs