pp kee guard web

35
1

Upload: kee-safety

Post on 19-Jul-2015

669 views

Category:

Business


1 download

TRANSCRIPT

1

Kee® Guard

2

Freestanding, non-penetrative, collective roof edge protection system

Complies with EN ISO 13374 Class A

Kee® Guard

3

Features

Independently tested, exceeds all European Safety requirements

Provides Collective Protection for roofs of up to 10º pitch

Versatile modular construction

Three types of upright available

Standard Fittings and Tubes galvanised to BS EN ISO 1461

Recycled PVC counterweights

Available colour coated

Kee® Guard

4

Benefits

Quick and easy to install

No penetration of Roof Membrane

No welding, bending or threading on site

Low installation time and cost

Sections can be added to and changed on site

No special tools required

Recycled PVC weights are easy to handle and position, reducing installation time

Kee® Guard

5

Placement

Suitable for flat roofs of up to 10º pitch

Concrete

PVC single ply membrane roofs

Mineral felt

Asphalt

Kee® Guard

6

Components

KGU35 vertical postKGU35 vertical postKGU35 vertical postKGU35 vertical post

1100mm high

Locator for the counter weights

Supplied as assembly

Fitted standard with 2 off 135-8

Kee Klamp saddle fittings

Kee® Guard

7

Components

KGU35 Upright Assembly

Kee® Guard

8

Components

CounterweightsCounterweightsCounterweightsCounterweights

13.5 kg to 16.5 kg

460 x 500 x 85 mm

Carrying handles moulded into the design

Available in black as standard

Orange available where required to highlight a trip hazard.

Other colours available by request at extra cost

Environmentally friendly, made from 100% recycled material in the EU

Kee® Guard

9

Components

CB1P CounterCB1P CounterCB1P CounterCB1P Counter----weights assemblyweights assemblyweights assemblyweights assembly

Used with each

intermediate upright

Tube 1075mm long

2.2m or 2m centres

Kee® Guard

10

Components

CB2P, CB3P, CB4P, CB7PCB2P, CB3P, CB4P, CB7PCB2P, CB3P, CB4P, CB7PCB2P, CB3P, CB4P, CB7P

Free end Counter-weight assemblies

Tube 1575mm long

Use dependent on edge distance, parapet up-

stand & length of run

Kee® Guard

11

Free end detail options

Roofs up to 10º pitch

1.1.1.1. RestrainedRestrainedRestrainedRestrained

Upright butted up against roof up- stand (min. 150mm) Use CB2P End Assembly

2.2.2.2. UnrestrainedUnrestrainedUnrestrainedUnrestrained

Where roof up-stand is less than 150mm Use CB7P End Assembly

Max bay size 2m

Max bay size 2m

Min

300mm

Kee® Guard

12

Free end detail options

Roofs up to 3º pitch

1.1.1.1. RestrainedRestrainedRestrainedRestrained

Upright butted up against roof up-stand (min. 150mm)

End bays 1.5 m. Use CB1P End Assembly

Max bay size 2.2m

CB1P

Kee® Guard

13

Termination options

Fixed ends

61-8 Wall Flange

Kee® Guard

14

Components

Top and midTop and midTop and midTop and mid----rails rails rails rails

48.3 mm diameter (size 8), Galvanised tube

Weight = 3.5-4.5 kg/m

Kee® Guard

15

Joints and corners

14-8 Joint for top & mid rails

15-8 90º Elbow

19-8 Adjustable Elbow, angles between 90-180º

55-8 Obtuse Angle Elbow, 125-178º angle

BC53-88 Swivel Elbow, adjustable inline

connection through 202º

14-8 15-8 19-8 55-8 BC53-88

Kee® Guard

16

Termination options

Free EndsFree EndsFree EndsFree Ends

‘D’ Return

Cut ends, finished with 77

plastic plug

Kee® Guard

17

Installation

Tools requiredTools requiredTools requiredTools required

Hex key socket screw size 5/16" AF

Torque wrench (10- 60 Nm approx).

Tape measure

50 mm tube cutter

Drill with suitable drill bit (for wall connection)

KeeGuard® Lite

19

Complies With EN 14122

Part 3

Lightweight Aluminium

construction

Non-penetrative

Reduces roof loadings

High corrosion resistance

KeeGuard® Lite

20

Suitable for flat roofs of up to

3º pitch

Concrete

PVC single ply membrane

roofs

Mineral felt

Asphalt

KeeGuard® Lite

21

Freestanding

KGU45 vertical post KGU45 vertical post KGU45 vertical post KGU45 vertical post

48.3 mm dia. (size 8) tube

1100 mm high

5.4 kg

Uses 45-87 fittings

KeeGuard® Lite

22

Components

Top and mid-rails

42.4 mm Dia. (size 7),

1.17 kg/m

KeeGuard® Lite

23

Components

L14-8 Straight coupling

L15-8 90º Elbow

L19-8 Adjustable Side Outlet Tee

Angles between 60-200º

LB54-88 Adjustable Elbow

Adjustable between 45-200º

61-8 Wall fixings

C58-8 Wall fixings

L14L14L14L14----8888

L15L15L15L15----8888

L19L19L19L19----8888

LB54LB54LB54LB54----88888888

61616161----8888

C58C58C58C58----8888

KeeGuard® Lite

24

Kee Guard Lite Fully Restrained Kee Guard Lite Fully Restrained Kee Guard Lite Fully Restrained Kee Guard Lite Fully Restrained system layouts

4.5m plus continuous run

KeeGuard® Lite Standing

Seam

26

Special fixing clamp suits most

available standing seam systems

Modular system supplied in

prefabricated kit form

Uses a non penetrative clamp

Complies with BS EN ISO 14122

Part 3

Optional colour coating in all RAL

colours available

KeeGuard® Lite Standing

Seam

27

Components

Seam Clamp ( KLSSB0030 )Seam Clamp ( KLSSB0030 )Seam Clamp ( KLSSB0030 )Seam Clamp ( KLSSB0030 )

316 stainless steel

Two part clamp

Non-penetrative

Tightened to 20Nm

KeeGuard® Lite Standing

Seam

28

Components

L14-8 Straight coupling

L15-8 90º Elbow

L19-8 Adjustable Side Outlet Tee

Angles between 60-200º

LB54-88 Adjustable Elbow

Adjustable between 45-200º

61-8 Wall fixings

C58-8 Wall fixings

L14L14L14L14----8888

L15L15L15L15----8888

L19L19L19L19----8888

LB54LB54LB54LB54----88888888

61616161----8888

C58C58C58C58----8888

Topsheild

30

Top fix guardrail system

For metal profile roofs

Up to 10º pitch

Sealing strip ensures integrity of the roof

Galvanised to ISO 1461

Topsheild

31

For metal profile roofs minimum

thickness 0.7mm

Fixed using Tek screws

To suit crown centres of:

250mm, 310mm, 333mm,

400mm, 500mm

Topsheild

32

BASE ASSEMBLIES MUST BE SPACED AT 2M CENTRES.

THE GAP BELOW THE BOTTOM RAIL SHOULD NOT EXCEED 470MM, MEASURED FROM ANY RAISED ROOF EDGE OR

PARAPET. IF THERE IS NO PARAPET, RAISED EDGE, ETC.., TOE BOARDS OF NOT LESS THAN 150MM HIGH MUST BE FITTED.

WHERE THE SYSTEM IS UNDER 6M OVERALL THE BAY END MUST NOT PROTRUDE MORE THAN 50MM FROM THE

LAST LEG. FOR ALL SYSTEMS 6M OR OVER, THE BAY END MAY PROTRUDE UP TO A MAXIMUM OF 500MM.

DIMENSIONS 'A' + 'B' MUST NOT TOTAL MORE THAN 2.5M.

2M MAX.SEE NOTE 3 'A'2M MAX.

BAY JOINING

CONNECTORS

SE

E

NO

TE

2

470

MM

MA

X.

'B'

SE

E N

OT

E 3

0.9

1M

- 1

.1M

MA

X.

1.

2.

3.

4.

'D' RETURN

33

Maintenance

The KeeGuard® systems are virtually maintenance-free.

Replace any damaged parts or grub screws with original spare parts.

Use clean water for cleaning. Use of hose or high-pressure washer is permitted.

Sustainability

The systems are made predominantly of ferrous and non-ferrous metals and can therefore be disposed of in a scrap metal facility.

The PVC weights can be returned to Kee Safety Ltd for re-cycling.

34

Kee Safety Ltd

35

1 Boulton Road

Reading

RG2 0NH

United Kingdom

Tel: +44 (0) 118 931 1022

Fax: +44 (0) 118 931 1146

Email: [email protected]