Dow Electrical & TelecommunicationsEnhanced Performance
MV Cable Insulation
What does DOW ENDURANCE™ HFDC 4202 EC do for utilities?
Life extension
Enhanced reliability / better asset utilization Ease of installation
Optimized costs, consistent installation Significantly Lower (~50%) water tree growth rate
Longevity, lower probability of failures Higher quality cables
Manufacturing consistency MV 105 C Rating for the material
Option for higher ampacity, when needed
How do we create the value?
Critical performance features for enhanced cable life…..
Higher electrical breakdown strength
Minimize electrical risks …water treeing in particular…
Improved / consistent cable installation
Eliminate accessory related risks
Improved cable quality Robust, consistent manufacturing that minimizes insulation related stresses due to fabrication process
Technology of DOW ENDURANCE™ HFDC 4202 EC
Same proven “Tree-retardant” additive technology used in 4202 for nearly 30 years.
Produced in totally integrated, state-of-the art facility − Feedstock to finished compound− Ongoing investments in continuous improvement
Extended cable life(enhanced formulation technology)
Improved ease of installation(reduced insulation shield stripping force)
Enhanced quality cable manufacturing(more robust processing)
.
Supporting Data
Electrical Data
Mechanical Data
Processing Data
Electrical Property Validation
Laboratory Plaque Data Water Tree Resistance Dissipation Factor ACBD Retention
Cable Data ACLT Results MV105C
Water Tree Size and Shape Changed with HFDC-4202 EC
ASTM D6097-97 Water Tree Test ASTM D6097-97 Water Tree Test Water Tree Retardance
4201 XLPE
B4202 TR-XLPE
C4202 TR-XLPE
0
0.1
0.2
0.3
0.4
0.5
0.6
XLPE TR XLPE C4202
Wat
er T
ree
Len
gth
(m
m)
Water Tree ComparisonASTM D6037; 30 day Aging
All 80x Magnification
Enhanced Wet Electrical Test Data
Enhanced Dow TR-XLPE – HFDC-4202 EC – demonstrates significant improvement over current commercial product
Actual Performance
DOW CONFIDENTIAL – Do Not Share Without Permission
HFDC 4202 ACLT Performance
ACLT Testing under “4,4” Conditions HFDB-4202 population at 1000 days aging - 0% remain Prototype HFDC-4202 at 1050 days aging - 53% remain Pilot plant HFDC-4202 at 830 days aging - 92% remain
Production Plant HFDC-4202• No failures out to 630 days• Aging continues…
C4202 demonstrating improved wet cable life
over B4202
C4202 demonstrating improved wet cable life
over B42029
DOW CONFIDENTIAL – Do Not Share Without Permission 10Testing on 1/0 15 kV cables
0
2
4
6
8
10
12
14
16
18
B4202/0693 C4202/0693 B4202/0693LS C4202/0693LS
Stri
p Fo
rce,
lb/0
.5"
Inital and Predicted after ICEA Cyclic Aging
Initial Thermally Conditioned
4
6
8
10
12
14
16
0 200 400 600 800 1000
Stri
p Fo
rce,
lb/0
.5"
Time (hrs)
Strip Force Stability vs Time Aging at 100C
B4202/0693 C4202/0693 B4202/0693LS C4202/0693LS
0
4
8
12
16
20
-20 0 20 40 60 80 100 120
Stri
p Fo
rce,
lb/0
.5"
Conditioning Temp (deg C) for 4hrs
Strip Force against Conditioning Temperature
B4202/0693 C4202/0693 B4202/0693LS C4202/0693LS
permission
Reduced Strip Force System
Commercialization Timeline
Compound Production Trial 1Q10
Dow material qualification cable testing initiated => 4Q10
Cable manufacturers qualification initiated => Complete*
ICEA Qualifications completed =>
Commercially Available => NOW!
120day = Data available360day = Data Available
.
*Southwire and Nexans have completed 120 AWTT testing
Volts / mil
HFDC - 4202 Qualification -Completed
Source-Nexans
ICEARequirement380 V/mil
Action Steps
We recommend utilities update their MV cable specifications to reflect the acceptance of DOW ENDURANCETM HFDC-4202 EC. Ask your cable manufacturer to provide cables with this insulation material.
Dow welcomes dialog on specific steps to make this happen
Dow also would like to understand your experience with the new compound: Do your line technicians like the lower strip capability? Do they think this makes the installation easier? Does this capability increase the likelihood of higher quality
accessory installation? Are there any issues with cables made from the new compound?
,.
Summary
DOW ENDURANCE™ HFDC 4202 EC TR-XLPE:
Continues great tradition of high quality insulation compounds, based on proven experience and TR technology of the past 28 years
Confirms Dow’s commitment to continuous improvement and bringing value added solutions to the industry
Has enhanced electrical performance (projected longer life), higher water tree retardance, lower and consistent insulation shield strip force and robust cable manufacturing
Provides superior performance solutions for power delivery industry. With the ICEA qualifications complete, trial installations can move forward.
HFDC - 4202 Qualification Update
Volts / mil
HFDC - 4202 Qualification Update
ICEA Qualification Progress-120 Days
.
Material CombinationsSource-averages of data from Nexans and Southwire ongoing cable qualifications
ICEA Qualification Progress-180 Days
.
Material Combinations
Source-ongoing cable qualification by Southwire Company
AWTT Qualification Testing
ICEA Qualification Completion-360 Days
.
Material CombinationsSource-completed cable qualification by Southwire Company
AWTT Qualification Testing
ICEA requirement380 v/mil