pre-fire survey name here. amidships crane- 01 qtr deck midships zone: 3
TRANSCRIPT
Pre-Fire Survey
NAME HERE
Amidships Crane- 01 Qtr Deck Midships
Zone: 3
Adjacent Spaces: FWD
• Fwd House:• Damage Control Locker #1• C/M Office• State Rooms• Fan Room • QTR Deck Office
Adjacent Spaces: Aft
• Aft House• Medical Wardroom• Sick Bay• State Rooms• Linen Locker• Fan Room• X-Ray room • Medical Laundry Room
Adjacent Spaces: PT/STBD
• PT/STBD Sides• Deck Lockers• Cranes• Lifeboats
Adjacent Spaces: Above
• Staterooms• Open Space• Fast rescue boats
Adjacent Spaces: Below
• Lower Class Mess• Chill Rooms• Purser’s Office• Crane Electrical Panels,
transformers, breakers
Fuel Loads:
Class A:• PFD’s• Lifeboat lines and rescue boat covers• Linen locker• Mattresses, State room items, Personal effectsClass B: • Hydraulic fluid,• Gasoline in rescue boats and power washer • Diesel in Lifeboats #1, #2• Freon refrigerant gas• Medical suppliesClass C: • Electrical circuitry in passage ways• Crane electrical panel (Main deck)Class D: None Nearby *Other Hazards: • Oxygen tanks in medical ward
Nearest Fire Stations
Fire Stations• F.S. #21:FWD House
STRB Side (1 ½ inch adj. nozzle)
• F.S. #22:FWD House PT Side (1 ½ inch adj. nozzle)
• F.S. #23:Interior-Aft House PT Side (1 ½ inch adj. nozzle)
• F.S. #24: Interior-Aft House STRB Side (1 ½ inch adj. nozzle)
• F.S. #25:Aft House STRB Side (1 ½ inch adj. nozzle)
• F.S. #26:Aft House PT Side (1 ½ inch adj. nozzle)
• *All fire stations have a 50 ft. hose
Nearest Fire Extinguishers
Powder
• (6)10 lb
CO₂
• (2) 15 lb
Accessibility
Primary Fire Stations
• Fire Stations 21 & 22
Secondary Fire Stations
• Fire Stations 25 & 26• Additional hoses may be
used from interior Fire Stations 23 & 24
Size and Capacity
Shutoffs: Fuel
• Crane Shut Offs• EOS• Main Deck Electrical Panel • Valve shut off at crane
Shutoffs: Ventilation
Shutoffs: Electrical
•
• Cargo Crane • Electrical Shut Off
Drains
• Scuppers are located along the port and starboard sides
(Main deck to 04)
Exposures
• 02 FWD House Electrical Locker• Medical Wardroom & Exam Room• 01 FWD House Deck Lockers
Divisions: Deck and Deckhead
• Fwd A-Class 0• Aft B-Class 0
Bulkhead Class: ARequirements: A-0 60 min test no passage of flame or smoke 3mm thick steel and suitably stiffened
Bulkhead Class: BRequirements: A-0 60 min test no passage of flame or smoke 1.5 mm thick steel and suitably stiffened
Divisions: Doors
• B-Class Aft (15)• A-Class Fwd (15)
Divisions: Bulkheads
• A-Class 0 Fwd • B-Class 0 Aft
Bulkhead Class: ARequirements: A-0 60 min test no passage of flame or smoke 3mm thick steel and suitably stiffened
Bulkhead Class: BRequirements: A-0 60 min test no passage of flame or smoke 1.5 mm thick steel and suitably stiffened
Fire Systems
Fixed Fire Suppression Systems
• N/A
Fire Detection Systems
• Smoke Detectors: FWD and Aft passage ways and all rooms
• Heat Detectors: N/A
Mid Ships Crane Pre-Fire Survey