Precision tests of calculated internal-conversion

coefficients: the case of 134Cs.

W. E. RockwellCyclotron Institute, TAMU

Summer 2005Advisor: J. C. Hardy

W. E. RockwellCyclotron Institute, TAMU

Summer 2005Advisor: J. C. Hardy

Page 2: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Outline

• Background: -decay– Internal conversion– Define internal conversion coefficient

• Two theories:– Hole and no hole

• Purpose• Experiment• Results/Calculations• Conclusion

Page 3: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

-Ray Emission

Gamma-ray emission can occur during the

de-excitation of a nucleus. Energy is

released in the form of an electromagnetic wave of high energy called a gamma ray.

Page 4: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Internal Conversion

Internal conversion is a transition that competes

with gamma ray emission. When internal conversion takes place the energy from the de-excitation of the nucleus

is transferred to an atomic electron. The

electron is then ejected with some kinetic energy.

Page 5: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

What is an Internal Conversion Coefficient (ICC) and why do we care?

The internal conversion coefficient of a transition is defined as the ratio of

the probabilities of internal conversion to -

ray emission for that transition.

Importance:• Nuclear decay schemes

– Spin and parity assignments, Transition rates, Branching ratios

• Detector calibration

Page 6: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Theoretical Problems• Calculated ICC values depend

strongly on how the theory deals with the hole left by the departing conversion electron.

• One approach assumes that it is filled instantaneously, while the other considers that it stays empty throughout the entire conversion process.

• The problem with the “no hole” theory is that in fact the electron leaves the atom in less time than it takes for the atomic hole to be filled.

Page 7: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

More Problems

• Most calculated results of ICCs are only known to agree with experimental results on an average of a few percent, and there are some cases of much more significant discrepancies.

• To date there are few exact measurements of ICCs with an uncertainty below one percent and this lack of precision makes it difficult to be definitive about the validity of either treatment of the hole.

Page 8: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Purpose

• In S. Raman et al, Phys. Rev. C 66, 044312 (2002) experimental values of ICCs were used to help make the argument that the “no hole” theory fit the experimental data better.– For 134Cs, both theoretical values disagreed with

experiment.– The uncertainty of the 134Cs experimental value was

nearly two percent.• Our experiment:

– For our experiment we aimed to have an uncertainty less than one percent in order to achieve a demanding test of the theories.

Page 9: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C
Page 10: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Experiment• Made solutions of CsNO3, CsCl,

Cs2CO3 using very pure chemicals. CsNO3-99.999% CsCl-99.999% Cs2CO3-99.995%

• Made a thin circular layer of very diluted insulin on a 1 inch square of Mylar.

• Dropped 0.05 ml of each solution on layer of insulin.

• Dried drops using vacuum chambers and a dry box and covered with hat shaped tops

• Neutron activated samples at TRIGA reactor in the Texas A & M University Nuclear Science Center

133Cs(n, ) 134Cs

• Used a disposable vacuum bag to cut off hat-like top and covered sample with Kapton tape.

• Placed sample exactly 15.1 cm from detector and took 3-5 consecutive spectra.

Page 11: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Decay Scheme

ENDSF website

Page 12: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

DataWe used two spectra from our CsCl source and one from the CsNO3 source.

134Cs

Page 13: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C
Page 14: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

137Ba

Page 15: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C
Page 16: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

We used nuclide and radiation searches in order to identify the peaks caused by the impurities. For the searches we used the Nuclear Science Division LBNL website.

Impurity Analysis

Page 17: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

TORI Data (1999) Gammas from 122Sb (2.7238 d 2)

E (keV)     I (%)     Decay mode

564.119 17  71  - 

692.794 17  3.85 13  - 

1256.901 19  0.81 4  - 

692.70 20 1.08 13 - 3.130 h 9 112Ag

692.794 171.355 25

++ 3.63 m 6 122I

692.794 17 3.85 13 - 2.7238 d 2 122Sb

692.8 1 0.024 ++ 16.01 h 13 170Hf

692.8 4 0.07 5 ++ 4.3 m

E (keV)   

I (%)   Decaymode   

Half life    Parent  

If we can make an educated guess as to what the impurity is we can use an nuclide search to confirm its identity. For instance if we guess that the peak is 122Sb then we can see from the nuclide search there should also be a peak at 564.1. The ratios of the areas of the two peaks should also correspond with that ratio of the intensities 71 and 3.85.

If we don’t have a have any solid ideas about what impurity causes the peak then we can use a radiation search to look for possible nuclides. The nuclides found are then tested using the same methods as before.

* Tables from LBNL website

Page 18: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Impurity AnalysisThe major impurities found were 56Mn, 122Sb, 124Sb, 134Cs, 82Br and 80Brm .

Page 19: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

After finding all the impurities, we checked to see which impurities could have peaks that would over lap with the peaks we are concerned about (~30-35 keV, 127keV). In our case 122Sb, 124Sb and 80Brm had peaks that could overlap with our peaks of interest. It is important to note that the actual overlap is quite small but because we want a very exact measurement we correct for the added area to our peaks.

Page 20: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C
Page 21: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Calculations/Results

K

K

KK N

N

1

K-shell ICC

fluorescence yield

peak area

detector efficiency

Subscript K designates K-x rays, which result from internal conversion, and subscript designates the transition -rays

N

K

K

Page 22: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

From the figure you can see the ratio of 137Ba and you can also see how closely the K-x rays overlap so that the efficiency are nearly the same.

The efficiency of our detector is not well known for energies less than 50 keV. Since our K-x rays are less than 50 keV we used a ratio of ICCs of 134Cs to 137Ba in order to minimize our uncertainty. 137Ba was used because it has K-x rays at almost the exact same energies as 134Cs.

Page 23: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

The subscript 1 indicates 134Ce and the subscript 2 indicates 137Ba

1

2

2

1

1

2

2

1

1

2

2

1

K

K

K

K

K

K

K

K

N

N

N

N

1

2

2

1

2

2

1

1

1

2

2

1

K

K

K

K

K

K

K

K

N

N

N

N

0048.18760.22566.

16297.2

894.0

900.0

2

1 K

K

)30(82.292

1 K

K

Ratio of the ICC of 134Cs to 137Ba

Page 24: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C

Conclusions

• From our experiment we can see that the experimental value for the ICC of 134Cs in Raman et al, Phys. Rev. C 66, 044312 (2002) was incorrect.

• This results together with our earlier measurement of 193mIr indicates that the conclusion drawn in this paper needs to be re-examined and more precise measurements are needed.

• Next we plan on examining the ICC of 139La

Page 25: Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C