Premium Ventilation1
Eugene Water & Electric Board
![Page 2: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/2.jpg)
Premium Ventilation2
Review Recommendations for Premium Western Economizer
• Primary sensor control location
• Two-stage thermostat & coordination
• Differential dry-bulb outside air changeover
• Adequate air flow and exhaust relief
• Ventilation control
• Quality Assurance
![Page 3: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/3.jpg)
Premium Ventilation3
Desired Sequence
• Min OSA ventilation during heating
• Use ventilation before cooling
• Use full OSA vent with cooling coil
• Lock out or Change over from ventilation to minimum when OSA too warm
![Page 4: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/4.jpg)
Premium Ventilation4
Premium Ventilation
• Start with a Western Premium Economizer
• Upgrade the Economizer module with – DCV capable economizer control module
– CO2 Sensor; Min air set to 0% = leakage
• Add variable speed fan motor– Full (or near full) speed in heating or cooling– Low (30%) speed in idle mode
![Page 5: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/5.jpg)
Premium Ventilation5
Triple the Savings
• Premium Economizer Savings, plus
• Fan savings when not heating or cooling
• Savings during warm-up by reducing ventilation when not occupied
• Ventilation heating and cooling savings when building not fully occupied
• No need to set and measure outside air minimum
![Page 6: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/6.jpg)
Premium Ventilation6
Regional Savings
0
2,000
4,000
6,000
8,000
10,000
12,000
PhoenixAZ
Sac'toCA
Eugene OR
Boise ID
Burl'ton VT
ChicagoIL
MemphisTN
HoustonTX
HV
AC
kW
h p
er
10
00
sq
ua
re f
ee
t Remaining Fan & Aux
Remaining Cooling
Remaining Heating
Evap pre-cool
VSD fan
DCV
Integrated Economizer
warmup cycle
Strip Heat lockout
Optimum Start
Total ECM Savings
Base Total HVAC
![Page 7: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/7.jpg)
Premium Ventilation7
New Units or Retrofit
• Retrofit VSD Options– ICM CC750– Fan Handler
• Both use temperature control strategy
![Page 8: Premium Ventilation1 Eugene Water & Electric Board](https://reader038.vdocument.in/reader038/viewer/2022110400/56649dcf5503460f94ac4973/html5/thumbnails/8.jpg)
Premium Ventilation8
Currently Custom Incentives
• Move towards rebate approach
• Two contractors have proposals for work
• New Construction and Replacement market