prepared for site name: buckingham
TRANSCRIPT
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
T-1
PREPARED FOR
NMID TX UTCOCAAZ - - - --- NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
TITLE SHEETDO NOT SCALE DRAWINGSTHESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTOR SHALL VERIFY ALL PLANS ANDEXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY NOTIFY THEARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK ORMATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.HANDICAP REQUIREMENTS
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP ACCESS IS NOTREQUIRED PER CBC2016, SECTION 11B-203.4 (LIMITED ACCESS SPACE)
OCCUPANCY : U (UNMANNED COMMUNICATIONS FACILITY)
CONSTRUCTION TYPE: V-B
APPROVED BY: INITIALS: DATE:
VENDOR:
LEASING / LANDLORD:
R.F.:
ZONING:
CONSTRUCTION:
POWER / TELCO:
PG&E:
DIRECTIONS FROM VERIZON's OFFICE AT 2785 MITCHELL DR., WALNUT CREEK, CA 94598
SITE NAME: BUCKINGHAM
1. DESTINATION TO: 226 BELLA VISTA ROAD, VACAVILLE, CA 95687
2. HEAD NORTHEAST ON MITCHELL DR TOWARD OAK GROVE RD
3. TURN LEFT ONTO OAK GROVE RD
4. USE THE LEFT 2 LANES TO TURN LEFT ONTO TREAT BLVD
5. TURN RIGHT ONTO BUSKIRK AVE
6. USE THE LEFT LANE TO TAKE THE INTERSTATE 680 N RAMP
7. MERGE ONTO I-680 N
8. KEEP LEFT AT THE FORK TO STAY ON I-680 N
9. KEEP LEFT AT THE FORK TO CONTINUE ON I-680
10. USE ANY LANE TO TAKE EXIT 71A TOWARD I-80 E/SACRAMENTO
11. MERGE ONTO I-80 E
12. TAKE EXIT 54A FOR DAVIS ST
13. TURN RIGHT ONTO BELLA VISTA RD
14. TURN LEFT
15. DESTINATION WILL BE ON THE LEFT
VERIZON WIRELESS:
LOCATION CODE: 299951
226 BELLA VISTA ROAD
VACAVILLE, CA 95687
JURISDICTION: CITY OF VACAVILLE
SITE TYPE: MONOPINE / OUTDOOR EQUIPMENT
Property Information:Site Name: BUCKINGHAMLocation Code: 299951
Site Address:226 BELLA VISTA ROADVACAVILLE, CA 95687
A.P.N. Number: 0127-220-040
Current Use: MULTIUSEProposed Use: MULTIUSE, COMMUNICATIONSFACILITY
Jurisdiction: CITY OF VACAVILLE
Latitude (NAD 83): 38.34713056 38° 20' 49.67" NLongitude (NAD 83): -121.9906611 121° 59' 26.38" W
Ground Elevation: 48.94' AMSL (NAVD 88)
Power Agency:PG&Eph: (408) 261-5373
Telephone Agency:AT&T
Property Owner:SMITH TOWN, LLC226 BELLA VISTA RD.VACAVILLE, CA 95687(949) 428-7070
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITHTHE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNINGAUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOTCONFORMING TO THESE CODES.
1) 2016 CALIFORNIA ADMINISTRATIVE CODE, CHAPTER 10, PART 1, TITLE 24 CODE OFREGULATIONS
2) 2016 CALIFORNIA BUILDING CODE (CBC)
3) 2016 CALIFORNIA RESIDENTIAL CODE (CRC) WITH APPENDIX H, PATIO COVERS, BASEDON THE 2012 IRC (PART 2.5)
4) 2016 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) (PART 11)(AFFECTED ENERGY PROVISIONS ONLY)
5) 2016 CALIFORNIA FIRE CODE (CFC), BASED ON THE 2012 IFC, WITH CALIFORNIAAMENDMENTS (PART 9)
6) 2016 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2012 UMC (PART 4)
7) 2016 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2012 UPC (PART 5)
8) 2016 CALIFORNIA ELECTRICAL CODE (CEC) WITH CALIFORNIA AMENDMENTS, BASEDON THE 2011 NEC (PART 3)
9) 2016 CALIFORNIA ENERGY CODE (CEC)- PART 6
10) ANSI / EIA-TIA-222-G
11) 2016 NFPA 101, LIFE SAFETY CODE
12) 2016 NFPA 72, NATIONAL FIRE ALARM CODE
13) 2016 NFPA 13, FIRE SPRINKLER CODE
T-1 TITLE SHEET 0
GN-1 GENERAL NOTES 0
LS-1 TOPOGRAPHIC SURVEY 1
A-1 OVERALL SITE PLAN 0
A-2 PROPOSED ENLARGED SITE PLAN 0
A-3 PROPOSED EQUIPMENT PLAN 0
A-4 PROPOSED ANTENNA PLAN AND DETAILS 0
A-5 PROPOSED SOUTH AND EAST ELEVATIONS 0
RFDS VERSION: 1.00.00DATE: 11/07/16
SITESITE
PROJECT INFORMATION PROJECT TEAM SHEET INDEX REVPROJECT DESCRIPTION
CODE COMPLIANCE VICINITY MAP LOCAL MAP DIRECTIONS FROM VERIZON
GENERAL CONTRACTOR NOTESAPPROVALSOCCUPANCY AND CONSTRUCTION TYPESTRUCTURAL: STRUCTURAL ANALYSIS IS NOT WITHIN THE SCOPE OF WORK CONTAINED IN THIS DRAWINGS SET.FOR ANALYSIS OF EXISTING AND/OR PROPOSED COMPONENTS, REFER TO STRUCTURAL ANALYSIS PROVIDEDUNDER SEPARATE COVER.
ANTENNA MOUNT ANALYSIS IS NOT WITHIN THE SCOPE OF WORK CONAINED IN THIS DRAWING SET. FORANALYSIS OF MOUNT TO SUPPORT EXISTING AND/OR PROPOSED COMPONENTS, REFER TO ANTENNA MOUNTSTRUCTURAL ANALYSIS PROVIDED UNDER SEPARATE COVER.
STATEMENTS
Architect / Engineer:J5 INFRASTRUCTURE PARTNERScontact: DANIEL DEWITTEemail: [email protected]: (949) 247-7767 x 109
Zoning Mgr.:J5 INFRASTRUCTURE PARTNERScontact: BRIAN MOOREemail: [email protected]: (510) 480-5574
RF Engineer:VERIZON WIRELESScontact: JENNIFER VALENCIAemail: [email protected]: (916) 357-2567
Applicant / Lessee:VERIZON WIRELESS2785 MITCHELL DR.WALNUT CREEK, CA 94598
Construction Mgr.:J5 INFRASTRUCTURE PARTNERScontact: DAN STEPLIGHTemail: [email protected]: (707) 761-5795
INSTALLATION OF A NEW SITE BUILD, UNMANNED TELECOMMUNICATIONS FACILITY,CONSISTING OF THE FOLLOWING:AT&T WIRELESS PROJECT SCOPE WILL CONSIST OF THE FOLLOWING:
· INSTALL PROPOSED VERIZON WIRELESS 364 SQ. FR. EQUIPMENT COMPOUND SURROUNDED
BY 8' HIGHCHAIN LINK FENCE WITH SLATS
· INSTALL PROPOSED VERIZON WIRELESS APPROVED OUTDOOR EQUIPMENT ON PROPOSED
14'-6" x 15'-0" CONCRETE PAD
· INSTALL (1) PROPOSED VERIZON WIRELESS 80'-0" HIGH MONOPINE WITHIN THE EQUIPMENT
COMPOUND
· INSTALL (2) PROPOSED GPS WITHIN PROPOSED EQUIPMENT COMPOUND
· INSTALL (12) PROPOSED VERIZON WIRELESS 8'-0" PANEL ANTENNAS
· INSTALL (12) PROPOSED VERIZON WIRELESS REMOTE RADIO HEADS (RRH)
· INSTALL (3) PROPOSED VERIZON WIRELESS RAYCAPS
· INSTALL (3) PROPOSED VERIZON WIRELESS EQUIPMENT CABINETS
· INSTALL (1) PROPOSED VERIZON WIRELESS UTILITY H-FRAME TO ACCOMMODATE
POWER/TELCO UTILITIES
· INSTALL PROPOSED VERIZON WIRELESS HYBRID CABLES
· INSTALL (1) PROPOSED VERIZON COAX CABLE ICE BRIDGE
· INSTALL UNDERGROUND POWER & TELCO TO PROPOSED SITE LOCATION
· APPROXIMATE ROUTING OF PROPOSED LESSEE, NON-EXCLUSIVE, 15' WIDE,
APPROXIMATELY 596' LONG ACCESS EASEMENT.
· APPROXIMATE ROUTING OF PROPOSED LESSEE, EXCLUSIVE, 5' WIDE, APPROXIMATELY
240'LONG, POWER & TELCO UNDERGROUND EASEMENT
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
GN-1
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
GENERAL NOTES
PLANS ARE INTENDED TO BE DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS,EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
1.
THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINEDOR IDENTIFIED BY THE CONTRACT DOCUMENTS.
2.
CONTRACTOR SHALL CONTACT USA (UNDERGROUND SERVICE ALERT) AT (800) 227-2600, FOR UTILITY LOCATIONS, 48 HOURS BEFOREPROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION.
3.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
4.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC / UBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, BUTNOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST COMPLYWITH LOCAL EARTHQUAKE CODES AND REGULATIONS.
5.
REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO IDENTIFY ORESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANYSURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT / ENGINEER PRIOR TOPROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THETRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TONOTIFY THE ARCHITECT / ENGINEER.
6.
THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OFWORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION.
7.
DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE LINES, UNLESS OTHERWISE NOTED.8.
ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLERECORDS. THE ARCHITECT / ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THEACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS SHALL BERESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION.CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES ANDMETHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES.
9.
CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANYDISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT / ENGINEER FORRESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BYTHE ARCHITECT / ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK ANDEXPENSE.
10.
ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISHELEVATIONS PRIOR TO FINAL INSPECTION OF WORK.
11.
ANY DRAIN AND/OR FIELD TILE ENCOUNTERED / DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL CONDITIONPRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELYNOTED AND PLACED ON "AS-BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT / ENGINEER AT COMPLETIONOF PROJECT.
12.
ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED INACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS.
13.
INCLUDE MISC. ITEMS PER VERIZON WIRELESS SPECIFICATIONS14.
SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCALAUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION.
THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN.
SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS:
- AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE- AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION- TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNASUPPORTING STRUCTURES- INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, ANDEARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OFELECTRICAL EQUIPMENT.-IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3"AND "HIGH SYSTEM EXPOSURE")
TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 NETWORKEQUIPMENT-BUILDING SYSTEM (NEBS): PHYSICAL PROTECTIONTELCORDIA GR-347 CENTRAL OFFICE POWER WIRINGTELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTSTELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS
ANY AND ALL OTHER LOCAL & STATE LAWS AND REGULATIONS
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OROTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND ASPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.
GENERAL CONSTRUCTION NOTES:
APPLICABLE CODES, REGULATIONS AND STANDARDS:
ABBREVIATIONS
SYMBOLS LEGEND
OFFICE101 ROOM NUMBER
WALL TYPE MARK
KEYNOTE,CONSTRUCTION ITEM
KEYNOTE,DIMENSION ITEM
ROOM NAME
WALL SECTION
DETAIL
W- 3
BLDG. SECTIONA-3001
A-500D5
A-310A5
A-113C1
A-113C4
A-113A1
A-113A4 ELEVATION
3
2
CENTERLINE
ELEVATION DATUM
TILT-UP PANEL MARK
WINDOW SYMBOL
DOOR SYMBOL
PROPERTY LINE
3
±0"
001
10
A GRID/COLUMN LINE
A-3001
A.B. ANCHOR BOLTABV. ABOVEACCA ANTENNA CABLE COVER ASSEMBLYADD'L ADDITIONALA.F.F. ABOVE FINISHED FLOORA.F.G. ABOVE FINISHED GRADEALUM. ALUMINUMALT. ALTERNATEANT. ANTENNAAPPRX. APPROXIMATE(LY)ARCH. ARCHITECT(URAL)AWG. AMERICAN WIRE GAUGEBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGBM. BEAMB.N. BOUNDARY NAILINGBTCW. BARE TINNED COPPER WIREB.O.F. BOTTOM OF FOOTINGB/U BACK-UP CABINETCAB. CABINETCANT. CANTILEVER(ED)C.I.P. CAST IN PLACECLG. CEILINGCLR. CLEARCOL. COLUMNCONC. CONCRETECONN. CONNECTION(OR)CONST. CONSTRUCTIONCONT. CONTINUOUSd PENNY (NAILS)DBL. DOUBLEDEPT. DEPARTMENTD.F. DOUGLAS FIRDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDWG. DRAWING(S)DWL. DOWEL(S)EA. EACHEL. ELEVATIONELEC. ELECTRICALELEV. ELEVATOREMT. ELECTRICAL METALLIC TUBINGE.N. EDGE NAILENG. ENGINEEREQ. EQUALEXP. EXPANSIONEXST.(E) EXISTINGEXT. EXTERIORFAB. FABRICATION(OR)F.F. FINISH FLOORF.G. FINISH GRADEFIN. FINISH(ED)FLR. FLOORFDN. FOUNDATIONF.O.C. FACE OF CONCRETEF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.O.W. FACE OF WALLF.S. FINISH SURFACEFT.( ' ) FOOT (FEET)FTG. FOOTINGG. GROWTH (CABINET)GA. GAUGEGI. GALVANIZE(D)G.F.I. GROUND FAULT CIRCUIT INTERRUPTERGLB. (GLU-LAM) GLUE LAMINATED BEAMGPS GLOBAL POSITIONING SYSTEMGRND. GROUNDHDR. HEADERHGR. HANGERHT. HEIGHTICGB. ISOLATED COPPER GROUND BUS
IN. ( " ) INCH(ES)INT. INTERIORLB.(#) POUND(S)L.B. LAG BOLTSL.F. LINEAR FEET (FOOT)L. LONG(ITUDINAL)MAS. MASONRYMAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTL. METAL(N) NEWNO.(#) NUMBERN.T.S. NOT TO SCALEO.C. ON CENTEROPNG. OPENINGP/C PRECAST CONCRETEPCS PERSONAL COMMUNICATION SERVICESPLY. PLYWOODPPC POWER PROTECTION CABINETPRC PRIMARY RADIO CABINETP.S.F. POUNDS PER SQUARE FOOTP.S.I. POUNDS PER SQUARE INCHP.T. PRESSURE TREATEDPWR. POWER (CABINET)QTY. QUANTITYRAD.(R) RADIUSREF. REFERENCEREINF. REINFORCEMENT(ING)REQ'D/ REQUIREDRGS. RIGID GALVANIZED STEELSCH. SCHEDULESHT. SHEETSIM. SIMILARSPEC. SPECIFICATIONSSQ. SQUARES.S. STAINLESS STEELSTD. STANDARDSTL. STEELSTRUC. STRUCTURALTEMP. TEMPORARYTHK. THICK(NESS)T.N. TOE NAILT.O.A. TOP OF ANTENNAT.O.C. TOP OF CURBT.O.F. TOP OF FOUNDATIONT.O.P. TOP OF PLATE (PARAPET)T.O.S. TOP OF STEELT.O.W. TOP OF WALLTYP. TYPICALU.G. UNDER GROUNDU.L. UNDERWRITERS LABORATORYU.N.O. UNLESS NOTED OTHERWISEV.I.F. VERIFY IN FIELDW WIDE (WIDTH)w/ WITHWD. WOODW.P. WEATHERPROOFWT. WEIGHTC CENTERLINEP PLATE, PROPERTY LINE
GROUT OR PLASTER
(E) BRICK
(E) MASONRY
CONCRETE
EARTH
GRAVEL
PLYWOOD
SAND
PLYWOOD
SAND
(E) STEEL
MATCH LINE
GROUND CONDUCTOR
TELEPHONE CONDUIT
POWER CONDUIT
COAXIAL CABLE
Tel
Pwr
Coax
CHAIN LINK FENCE
OVERHEAD SERVICE CONDUCTORSOH
LL
WOOD FENCE
(P) ANTENNA
(P) RRU
(P) DC SURGE SUPPRESSION
(F) ANTENNA
(F) RRU
(E) EQUIPMENT
OH
E
OH
EO
HE
OH
E
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
E
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
E
OH
E
OH
EO
HE
OH
E
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
S
D
S
D
S
S
S
S
SS
SS
SD
W
W
W
W
W
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
A-1
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
OVERALL SITE PLAN
SECTOR "C"240°
AZIMUTH(LTE)
REFER TO ENLARGED SITE PLANON SHEETS A-2 & A-2.1
PROPOSEDPROJECT AREA
SECTOR "B"120°
AZIMUTH(LTE)
SECTOR "A"0°
AZIMUTH(LTE)
ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH ANDSTREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCELMAP AND EXISTING DRAWINGS AND ARE APPROXIMATE.
NOTES:
1. NO GRADING OR PERMANENT CONSTRUCTION SHALLOCCUR WITHIN DRIP LINES OF TREES THAT ARE TO REMAINWITHOUT ARBORIST APPROVAL.
2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TOCONTACT DIGALERT TO MARK OUT EXISTING UNDERGROUNDUTILITIES. IN THE EVENT OF CONFLICTS, CONTRACTOR TOCONTACT J5 INFRASTRUCTURE.
THIS IS NOT A SITE SURVEY
1 1" = 30'-0"OVERALL SITE PLAN
EXISTING UTILITY POLE
0"30' 30'15'24"x36" SCALE: 1" = 30'-0"11"x17" SCALE: 1" = 60'-0"
PROPOSED VERIZONWIRELESS 15' WIDE
ACCESS ROUTE
EXISTING OVERHEAD UTILITYLINES
PROPOSED FIBERPULL BOX LOCATION
PROPOSEDDARK FIBER AND
POWER ROUTE
EXISTING PARKING AREA
EXISTINGSTORAGE LOCKERS
EXISTINGSTORAGE LOCKERS
EXISTINGSTORAGE LOCKERS
EXISTING BUILDING
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
E
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
EO
HE
OH
E
SS
SD
W
XX
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
A-2
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
PROPOSED ENLARGED SITEPLAN
ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH ANDSTREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCELMAP AND EXISTING DRAWINGS AND ARE APPROXIMATE.
NOTES:
1. NO GRADING OR PERMANENT CONSTRUCTION SHALLOCCUR WITHIN DRIP LINES OF TREES THAT ARE TO REMAINWITHOUT ARBORIST APPROVAL.
2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TOCONTACT DIGALERT TO MARK OUT EXISTING UNDERGROUNDUTILITIES. IN THE EVENT OF CONFLICTS, CONTRACTOR TOCONTACT PDC.
THIS IS NOT A SITE SURVEY
1 1/8"=1'-0"PROPOSED ENLARGED SITE PLAN
REFER TO EQUIPMENT/ANTENNAPLANS ON SHEET A-3 & A-4
PROPOSEDPROJECT AREA
~ EXISTING ASPHALT DRIVE ~
EXISTING SOUND WALL
24"x36" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 0" 8'2'
EXISTING OVERHEAD UTILITYLINES
EXISTING BUILDING
EXISTING STORAGE LOCKERS
SECTOR "C"240°
AZIMUTH(LTE)
SECTOR "B"120°
AZIMUTH(LTE)
SECTOR"A"0°
AZIMUTH(LTE)
PROPOSED 12' WIDE ACCESS ROAD
PROPOSEDFIBER ROUTE
EXISTING STORAGE LOCKERS
EXISTING CONCRETE CURB
PROPOSEDELECTRICAL METER
EXISTING UTILITY POLE
XX
XX
XX
XX
XX
XX
XX
XX
X
X
X
X
X
X
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
A-3
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
PROPOSED EQUIPMENT PLAN
1 1/2" = 1'-0"PROPOSED EQUIPMENT PLAN
PROPOSED VERIZON WIRELESSRAYCAPS MOUNTED ON PROPOSED
H-FRAME
2' 1' 0" 2'24"x36" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
PROPOSED VERIZON WIRELESS 200AMAIN PANEL AND MOUNTED ON
PROPOSED H-FRAME
-48VPLANT
BATTERYCABINET
PROPOSED VERIZON WIRELESS 200AAPPLETON GEN PLUG MOUNTED ON
PROPOSED H-FRAME
PROPOSED VERIZON WIRELESS8'-0" H-FRAME
PROPOSED VERIZON WIRELESSFIBER CABINET
PROPOSED VERIZON WIRELESS 5'-0"COMPOUND ACCESS GATE
PROPOSED VERIZON WIRELESS 8'-0"HIGH CHAINLINK COMPOUND FENCE
PROPOSED VERIZON WIRELESSTOWER LOCATION
EXISTING ACCESS DOOR
EXISTING ACCESS GATE
PROPOSED VERIZON WIRELESSLED WORK LIGHT
PROPOSED VERIZON WIRELESSLED WORK LIGHT
EQUIPMENTCABINET
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
A-4
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
PROPOSED ANTENNA PLANAND DETAILS
SECTOR
A
L
P
H
A
B
E
T
A
G
A
M
M
A
ANTENNA MODEL NO.AZIMUTH
RAD CENTER RRU COUNT FIBER LENGTHCOAX LENGTH COAX DIA. COUNT
PROPOSED RF SCHEDULE
A1
A2
A3
A4
B1
B2
B3
B4
C1
C2
C3
C4
TMA
8' PANEL ANTENNA 0° 70'-0"
140°
±140'-0" ±10'-0" 1/2"
1/2"
6
6
1/2"
1/2"
1/2"
1/2"
PROPOSED VERIZON WIRELESS 8' PANELANTENNA MOUNTED ON PROPOSED PIPE
MAST MOUNTED ON PROPOSED CROSSMOUNT, TYP. 4 PER SECTOR - 3 SECTORS
(18) PROPOSED VERIZON WIRELESS RRU'sMOUNTED BEHIND PROPOSED PANELANTENNAS,(6 PER SECTOR, 3 SECTORS TOTAL)
±10'-0"
±10'-0"
±10'-0"
±10'-0"
±10'-0"
70'-0"
70'-0"
70'-0"
70'-0"
70'-0"
245°
1 3/4" = 1'-0"PROPOSED ANTENNA PLAN
2 NTSPROPOSED RF SCHEDULE
6
6
6
6
PROPOSED 80'-0" TALL VERIZONWIRELESS MONOPINE, LOCATION OFTOWER MOUNTED EQUIPMENT, REFER
TO SHEET A-4
0°
140°
245°
±140'-0"
±140'-0"
±140'-0"
±140'-0"
±140'-0"
SECTOR "C"240°
AZIMUTH(LTE)
SECTOR "B"120°
AZIMUTH(LTE)
SECTOR "A"0°
AZIMUTH(LTE)
1' 0" 1'24"x36" SCALE: 3/4" = 1'-0"11"x17" SCALE: 3/8" = 1'-0" 6"
70'-0"
70'-0"
70'-0"
0°
140°
245°
1/2" 6±10'-0"±140'-0"
1/2" 6±10'-0"
1/2"±10'-0" 6±140'-0"
1/2"±10'-0" 6
1/2"±10'-0" 6±140'-0"
1/2"±10'-0" 6
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
8' PANEL ANTENNA
70'-0"0°
70'-0"140°
70'-0"245°
±140'-0"
±140'-0"
±140'-0"
6
6
6
PROPOSED VERIZON WIRELESSRD3DC3315-PF-48 SURGEARRESTORS (TYP. 3 TOTAL)
XX
X
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensor:
Issued For:
Site ID:
SITE NAME:
226 BELLA VISTA ROADVACAVILLE, CA 95687
DWW
SR
BUCKINGHAM
BUCKINGHAM
0
BUCKINGHAMLOCATION CODE: 299951
11/16/17
A-5
PREPARED FOR
NMID TX UTCOCAAZ- - - ---
NV-
ZD 100%
2785 MITCHELL DR.WALNUT CREEK, CALIFORNIA 94598
PROPOSED SOUTH ANDEAST ELEVATIONS
2 1/4" = 1'-0"PROPOSED EAST ELEVATION
GRADE LEVEL±0'-0" AGL
1 1/4" = 1'-0"PROPOSED SOUTH ELEVATION
TOP OF PROPOSED MONOPINE±80'-0" AGL
TOP OF PROPOSED VERIZON WIRELESS PANEL ANTENNASTOP OF PROPOSED MONOPINE STEEL
±74'-0" AGL
PROPOSED VERIZON WIRELESS ANTENNA RAD CENTER±70'-0" AGL
BOTTOM OF PROPOSED VERIZON WIRELESS PANEL ANTENNAS±66'-0" AGL
PROPOSED 80'-0" TALL VERIZONWIRELESS MONOPINE, LOCATION OFTOWER MOUNTED EQUIPMENT, REFER
TO SHEET A-4
PROPOSED VERIZON WIRELESSEQUIPMENT CABINETS ONPROPOSED CONCRETE SLAB
PROPOSED VERIZON WIRELESS 8' PANEL ANTENNAMOUNTED ON PROPOSED PIPE MAST MOUNTED ON
PROPOSED CROSS MOUNT, TYP. 4 PER SECTOR - 3SECTORS
PROPOSED VERIZON WIRELESSUTILITY H-FRAME, REFER TOSHEET A-3 FOR DETAILS
(18) PROPOSED VERIZON WIRELESS RRU's MOUNTEDBEHIND PROPOSED PANEL ANTENNAS STACKED,
(6 PER SECTOR, 3 SECTORS TOTAL)
PROPOSED VERIZON WIRELESSHYBRID CABLE ROUTE WITHIN
PROPOSED MONOPINE
PROPOSED VERIZON WIRELESS 8'-0" HIGHCHAINLINK COMPOUND FENCETOP OF (E) SOUND WALL
±12'-0" AGL
(E) BUILDLING
(E) STORAGE LOCKERBUILDING-BEYOND WALL
PROPOSED FUTURE ANTENNAS BY OTHERS(SIZE, SPACING & AZIMUTHS T.B.D.)
PROPOSED VERIZON WIRELESSRD3DC3315-PF-48 SURGEARRESTORS (TYP. 3 TOTAL)
GRADE LEVEL±0'-0" AGL
TOP OF PROPOSED MONOPINE±80'-0" AGL
TOP OF PROPOSED VERIZON WIRELESS PANEL ANTENNASTOP OF PROPOSED MONOPINE STEEL
±74'-0" AGL
PROPOSED VERIZON WIRELESS ANTENNA RAD CENTER±70'-0" AGL
BOTTOM OF PROPOSED VERIZON WIRELESS PANEL ANTENNAS±66'-0" AGL
TOP OF (E) SOUND WALL±12'-0" AGL
PROPOSED VERIZON WIRELESS 8' PANEL ANTENNAMOUNTED ON PROPOSED PIPE MAST MOUNTED ON
PROPOSED CROSS MOUNT, TYP. 4 PER SECTOR - 3 SECTORS
(18) PROPOSED VERIZON WIRELESS RRU's MOUNTEDBEHIND PROPOSED PANEL ANTENNAS STACKED,
(6 PER SECTOR, 3 SECTORS TOTAL)
PROPOSED FUTURE ANTENNAS BY OTHERS(SIZE, SPACING & AZIMUTHS T.B.D.)
PROPOSED VERIZON WIRELESSRD3DC3315-PF-48 SURGEARRESTORS (TYP. 3 TOTAL)
(E) STORAGE LOCKERBUILDING
(E) BUILDLING
PROPOSED VERIZON WIRELESSEQUIPMENT CABINETS ON
PROPOSED CONCRETE SLAB
PROPOSED VERIZON WIRELESSUTILITY H-FRAME, REFER TO
SHEET A-3 FOR DETAILS
PROPOSED 80'-0" TALL VERIZONWIRELESS MONOPINE, LOCATION OFTOWER MOUNTED EQUIPMENT, REFER
TO SHEET A-4
PROPOSED VERIZON WIRELESSHYBRID CABLE ROUTE WITHIN
PROPOSED MONOPINE