presentación de powerpoint -...
TRANSCRIPT
SUSTAINABLE SOLUTIONS
ECOGEOSOLAR
MFS IDI is a MELFOSUR subsidiary company, which was born to give thetechnological and professional tools to get its clients to become more competitive.
MFS IDI’s mission is to develop especialized projects in the R&D renewables sector,achieving the creation of products with the best value.
We are:
Excellence, innovation, commitment
SUSTAINABLE SOLUTIONS
Over 25 years of historyWe have proven experience of over 25 years in the electricity sector.We are a global provider of efficient and sustainable energy solutions.The presence of Melfosur can be found throughout the entire energy cycle, from concept design to market introduction.
SUSTAINABLE SOLUTIONS
Melfosur has a strong international presence and vocation
SUSTAINABLE SOLUTIONS
Keys to successIntegration of activities for a full service
Melfosur performs an important activity in the green energies sector.
We have installed more than 20MW in this sector.
We are pioneers in project implementation, promotion andinstallation of solar photovoltaic and wind power.
We have set renewable energy for sustainable development, using thelatest technology for maximum efficiency and productivity.
SUSTAINABLE SOLUTIONS
We have developed and integrated in the same machine the brains and heart of aninstallation,for commercial, industrial or domestic purposes. :
- Maximum efficiency to transform electric power in heating and cooling.
- Smart management of multiple energy sources: conventional and renewable.
- Energy storage, load and unload of electric vehicles.
- Automatic optimization of consumption: Set up , control, remote management.
Ecogeosolar Hybrid System
SUSTAINABLE SOLUTIONS
Ecogeosolar:
SUSTAINABLE SOLUTIONS
Technological partners
SUSTAINABLE SOLUTIONS
COMPETITIVE ADVANTAGES
HIGHEST EFFICIENCY COEFFICIENT (COP/EER) FOR 1-PHASE HEAT PUMPS
COP = 4,9 EER = 6,9
AIT HOMOLOGATION( Austrian Institute of Technology)
CC/CA CONVERSION EFFICIENCY, PEAK 98,3%, AVERAGE 97,7%
EMC certificate ( Intertek)
REGULATORY COMPLIANCE INCLUDING GRID INTERCONNECTION AND
ELECTRIC SYSTEM LOAD AND UNLOAD:
FULFILLING THE STANDARDS IN 18 COUNTRIES:
BDEW, VDE0126-1-1, VDE-AR-N 4105, RD661, RD 1699, CEI 0-21
V2:2013, CEI 0-21, CEI 0-16 V1:2013, G59/2, UTE C15-712-1, AS4777/SI4777,
IEC 62116, IEC 61727, IEEE 1547 ,CSA 107.1
SUSTAINABLE SOLUTIONS
COMPETITIVE ADVANTAGES
INCLUDING COPELAND INVERTER TECHNOLOGY.
Inverter technology. Specifically developed for the Scroll compressor
High efficiencies unreachable with traditional heat pumps
Compact and economic installations:
Lower electric consumption
Higher durability and reliability
ELECTRONIC EXPANSION VALVE
Allows an accurate control of the refrigerant flow and a better use of the
evaporator to reach higher efficiencies.
SUSTAINABLE SOLUTIONS
THERMAL PRODUCTION ADAPTED TO THE DEMAND
Variable speed compressor management
PREDICTIVE-ADAPTATIVE MANAGEMENT SYSTEM. MAXIMUM CONSUMPTION
OPTIMIZATION
Internal/external processing for more than 200 system variables
Dynamic working setpoints
VPN communication predictive management, external server calculation
BATTERY POWER STORAGE
Modular Power System Load / Unload and Storage.
High accuracy unload management under monitoring of maximum
power point (MPPT) of the photovoltaic system,
Unload efficiency> 97 %.
COMPETITIVE ADVANTAGES
SUSTAINABLE SOLUTIONS
ELECTRIC VEHICLE BATTERY LOADING HIGH POWER MODULE
Load Manager includes interactive grid management and renewable resource.
SMART GRID COMMUNICATION MANAGEMENT MODULE. ENERGY EXCESS
MANAGER.
The device can interface mode Distributed Generation System with other computers
on network configuration and injection under one control center.
COMPETITIVE ADVANTAGES
SUSTAINABLE SOLUTIONS
DESIGNED TO LAST
Extreme climate conditions
Vibrations Divere user profilesCombined stress and
stretch
Diverse tests:
1. THB: Temperature humidity bias
2. Salt-Fog testing
3. HALT: Highly accelerated life test
4. MEOST: Multiple Environmental over stress testing
5. Custom reliability testing
• Risk evaluation to save installation problems.
• Validation of the operating conditions even beyond ranges
• Identifying improvement points
SUSTAINABLE SOLUTIONS
Inverter technology, variable speed scroll compressor
SUSTAINABLE SOLUTIONS
Maximum energy savings:Liquid cooling system for the inverter
SUSTAINABLE SOLUTIONS
3 Cooling modules, cooling, heating, reverse cycle
3 cooling modules / heating and reverse cycle
SUSTAINABLE SOLUTIONS
microPC control system
SUSTAINABLE SOLUTIONS
User friendly Interface
SUSTAINABLE SOLUTIONS
● Copeland compressor and inverter
● Electronic expansion valve in every model
● Variable speed, high efficiency, A class circulation pumps for the brine andheating circuits.
● Temperature and pressure sensors in water and refrigerant circuits
● R410A, the best refrigerant for heat pumps
● Included expansion vessels, security and drain valves.
THERMAL TECHNOLOGY SYSTEM
SUSTAINABLE SOLUTIONS
● Scroll compressors and Inverter, COPELAND
● Electronic expansion valve, CAREL
● Circulation pumps, WILO
●microPC, CAREL, ONROM control
● Exchangers, ALFA LAVAL
● Auxiliary components, DANFOSS
● Stainless steel DHW tank and coil
THERMAL SYSTEM COMPONENTS
SUSTAINABLE SOLUTIONS
► New Copeland inverter technology
● Rpm variation, 1800 - 7000
● 2 diff. compressors-inverter, 3 - 12 kW y 5 - 22 kW
● 1-phase and 3-phase power supply
●ModBUS, inverter-compressor, inverter-control
● Power correction factor(cosφ ≈ 1)
● No current peaks
INVERTER TECHNOLOGY
SUSTAINABLE SOLUTIONS
► Instrumentation
● Temperature sensors
- Outlet/inlet heating, brine and aero-thermal
- Drain, discharge, inverter, oil
● Pressure sensors
- Compressor drain and discharge
- Heating and brine circuits
● Inverter electric consumption
● Compressor torque, max torque
THERMAL SYSTEM: INSTRUMENTATION - MANAGEMENT
SUSTAINABLE SOLUTIONS
► Design, “all in one concept”
● Includes brine and heating circulation pumps
● Includes expansion vessels
● Includes security valves
● Includes drain valves
● Includes flexible connection hoses
THERMAL SYSTEM: INTEGRATION
SUSTAINABLE SOLUTIONS
Heating power 3-12, 30/35 ºC
POWER
0
2
4
6
8
10
12
14
16
18
1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
Po
ten
cia
calo
rífi
ca (
kW
)
rpm
0 / -3 5 / 2 10 / 7
SUSTAINABLE SOLUTIONS
Heating power 5-22, 30/35 ºC
POWER
0
5
10
15
20
25
30
35
1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
Po
ten
cia
calo
rífi
ca (
kW
)
rpm
0 / -3 5 / 2 10 / 7
SUSTAINABLE SOLUTIONS
COP 5-22, 30/35 ºC
ecoGEO – COP
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
CO
P
rpm
0 / -3 5 / 2 10 / 7
SUSTAINABLE SOLUTIONS
► Hybrid technology
● Installation simplicity
► All in one concept, “plug and play”
● Fast installation and commissioning
► Simpler and more economic installations
INSTALLATIONS
SUSTAINABLE SOLUTIONS
CONFIGURATION OF THE GRID CONNECTION OPERATION ACCORDING TO THE STANDARD OF
DIFFERENT COUNTRIES
AUSTRALIAAUSTRALIA
AUSTRIA
GERMANY
BELGIUM
DENMARK
SPAIN
FRANCE
GREECE
ENGLAND
IRELAND
ISRAEL
ITALY
NETHERLANDS
PORTUGAL
CZECH REP.
THAILAND
USA
CANADA
SUSTAINABLE SOLUTIONS
ACTIVE POWER MANAGEMENT BASED ON THE FREQUENCY
SUSTAINABLE SOLUTIONS
REACTIVE POWER MANAGEMENT
f.d.p. variable
Q fijaCurvas de control de Q
SUSTAINABLE SOLUTIONS
LOW VOLTAGE PROTECTION PERIOD
SUSTAINABLE SOLUTIONS
Adaptive management SMART GREEN COMMUNITY
MODULE INTELLIGENT ENERGY EFFICIENCY
GENERATION CURVES
ESTIMATION
CONSUMPTION ESTIMATION
CURVESCo (iniciales)
PREDICTIVE
MANAGEMENT
CONSUMPTION
CURVES Cn
AVAILABLE
SAVINGS
DYNAMIC SETPOINT
VARIATION
COMMUNICATION MANAGEMENT MODULE
DISTRIBUTED GENERATION MANAGEMENT MODULE
SUSTAINABLE SOLUTIONS
IEE module: Consumption estimation
SUSTAINABLE SOLUTIONS
IEE: Consumption estimation
SUSTAINABLE SOLUTIONS
IEE module: Consumption estimation
SUSTAINABLE SOLUTIONS
IEE module: Consumption estimation
SUSTAINABLE SOLUTIONS
IEE module: Predictive management
SUSTAINABLE SOLUTIONS
IEE Module: Adaptive management, optimization functions
nvar = 4;
gaoptions = gaoptimset('Generations',15,'Display','iter');
startTime = tic;
ga(@expensive_objfun,nvar,[],[],[],[],[],[],[],gaoptions);
time_ga_sequential = toc(startTime);
fprintf('Serial GA optimization takes %g seconds.\n',time_ga_sequential);
Best Mean Stall
Generation f-count f(x) f(x) Generations
1 40 1.469 23.18 0
2 60 1.236 20.34 0
3 80 0.655 7.149 0
4 100 -0.9582 5.889 0
5 120 -1.876 4.473 0
6 140 -1.876 2.757 1
7 160 -1.958 0.2561 0
8 180 -2.387 2.363 0
9 200 -5.238 3.562 0
10 220 -23.18 2.033 0
11 240 -44.76 -1.239 0
12 260 -44.76 -12.72 1
13 280 -44.76 -23.8 2
14 300 -64.49 -34.12 0
15 320 -64.49 -42.11 1
Optimization terminated: maximum number of generations exceeded.
Serial GA optimization takes 40.2414 seconds.
SUSTAINABLE SOLUTIONS
Green Community Module: Communication management, next generation VPN Industrial server
SUSTAINABLE SOLUTIONS
Green Community Module: Communication management, next generation VPN Industrial server
SUSTAINABLE SOLUTIONS
3500
3000
2500
2000
1500
1000
500
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Meters
Meters
10
9
1112
1
15
20
17
161413
2
3
4 5 6
18
7
8
19
Load
P32P23
P132P1413
P34
P43 P54 P65
P45 P56 P67 P76
(5117;2912)
P1816
P1918
P19 P18
P98
P89
(3450;1300)
P10
P109
P910P1011
P110
P20
P11P1211
P1112
P12P112P1
P121
(1193;1694)(2732;1995)
P1720
P1516
P1314
P13
P213
P12P2
P21
P87P78
P8
P1618
P1819P1715
P2017
P1415P1715
P1517
Power Plant
3500
3000
2500
2000
1500
1000
500
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Meters
Meters
538 kVA10
9678 kVA4158 kVA
1112
4119 kVA
4125 kVA1
2205 kVA3804 kVA1340 kVA
15
20
1202 kVA
17207 kVA
16412 kVA
14749 kVA132
3 2692 kVA
89 kVA4
199 kVA5 6
821 kVA
2198 kVA
18
7
1096 kVA
8
1813 kVA3555 kVA
19
Loads
Dist. Gen.
Substation
Source 1 = Y
Source 2 = Z
Source 3 = V
Source 4 = W
W
(1193;1694) (2420;1758)
V
(2732;1995) Z
(3450;1300)
Y(5177;2912)
3500
3000
2500
2000
1500
1000
500
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Meters
Meters
538 kVA109678 kVA4158 kVA
11124119 kVA
4125 kVA1
2205 kVA3804 kVA
1340 kVA15
20 1202 kVA
17 207 kVA
16 412 kVA14
749 kVA132
32692 kVA
89 kVA
4
199 kVA
5 6
821 kVA
412 kVA18
7
1096 kVA
81813 kVA
3555 kVA19
Loads
Substation
4125 kVA
3801 kVA
4294 kVA
1109 kVA
2089 kVA
16024 kVA
(2420;1758)
1340 kVA
9277 kVA
4119 kVA
1409 kVA
1202 kVA
7574 kVA
4019 kVA
1821 kVA
1020 kVA821 kVA
1096 kVA
2909 kVA
3447 kVA
4125 kVA
3500
3000
2500
2000
1500
1000
500
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Meters
Meters
538 kVA109678 kVA4158 kVA
11124119 kVA
4125 kVA1
2205 kVA3804 kVA
1340 kVA15
20 1202 kVA
17 207 kVA
16 412 kVA14
749 kVA132
32692 kVA
89 kVA
4
199 kVA
5 6
821 kVA
412 kVA18
7
1096 kVA
81813 kVA
3555 kVA19
Loads
Substation
4125 kVA
3801 kVA
4294 kVA
1109 kVA
2089 kVA
16024 kVA
(2420;1758)
1340 kVA
9277 kVA
4119 kVA
1409 kVA
1202 kVA
7574 kVA
4019 kVA
1821 kVA
1020 kVA821 kVA
1096 kVA
2909 kVA
3447 kVA
4125 kVA
Green Community Module: Energy exchange management, distributed generation
SUSTAINABLE SOLUTIONS
Green Community mode: Distributed generation
SUSTAINABLE SOLUTIONS
ECOGEOSOLAR INSTALLATION
Advantages of the installations
● High economical savings
PONTEVEDRA150 m2
4 personasSUR
Vivienda bien aislada20/21 ºC
45
15901502
1310
918864
530
398 353
Coste de la energía en función del sistema [€/año]
Electricidad
Gasóleo
Propano
Caldera pellets
Caldera gas
naturalBC Aerotérmica
BC Geotérmica
tradicionalBC Geotérmica
ecoGEO
10,50 kW
13010,62 kW/año
78%
SUSTAINABLE SOLUTIONS
PONTEVEDRA
150 m2
4 people
SOUTH
Well isolated housing
20/21 ˚C
45
Energy cost according to the system
(€/year) Electric power
Gas boiler
Propane
Pellet boiler
ASHP
GSHP
ecoGEO
Natural gas boiler
CONNECTION TYPES: OFF GRID
SUSTAINABLE SOLUTIONS
GENERATOR
BATTERIES
CONNECTION TYPES: BACKUP
SUSTAINABLE SOLUTIONS
GENERATOR
GRID
BATTERIES
DOMESTIC CONSUMPTION
CONNECTION TYPES: ON GRID
SUSTAINABLE SOLUTIONS
BATTERIES
GENERATOR
GRID
INDUSTRIAL CONSUMPTION
Soporte de generador
Grid support
Selling to the grid
● Selling DC excess to the grid.
Grid support(LBX)
● Allows to lower the grid consumption byproviding renewable energy.
Reduction of the maximum consumption
● Limits the grid consumption by providingenergy from the battery.
Time regulation
● Loads the battery during the low pricing periodand expends such energy during daytime.
CONNECTION TYPES: INTERACTIVE NETWORK MODE
SUSTAINABLE SOLUTIONS
MULTIPLE INSTALLATIONS
SUSTAINABLE SOLUTIONS
CONNECTION TYPES: HYBRID MODE
INTERACTIVE GRID+ HVAC
SUSTAINABLE SOLUTIONS
EcoGeoSolar Hybrid System
Domestic Application:
1 Unit: modulation 5 to 22 kW
12 Units: Parallel connection management – modulation 5 to 264 kW
Industrial applications:
3-Phase modules: N units parallel connection management.
SUSTAINABLE SOLUTIONS
SUSTAINABLE SOLUTIONS
SUSTAINABLE SOLUTIONS
1-PHASE UL-USA: EFFICIENCY CURVES
SUSTAINABLE SOLUTIONS
1-PHASE UL-USA: OVERLOAD CAPACITY
SUSTAINABLE SOLUTIONS
1-PHASE EU EFFICIENCY CURVES
SUSTAINABLE SOLUTIONS
1-PHASE EU : OVERLOAD CAPACITY
Power decrease
Temperature (˚C)
SUSTAINABLE SOLUTIONS
3-PHASE EFFICIENCY CURVES
SUSTAINABLE SOLUTIONS
10kVA efficiency curves
Effi
cie
ncy
10kW efficiency
SUSTAINABLE SOLUTIONS
SUSTAINABLE SOLUTIONS
INFORMATION SCREENS
SUSTAINABLE SOLUTIONS
INFORMATION SCREENS
SUSTAINABLE SOLUTIONS
SETTING SCREENS
SUSTAINABLE SOLUTIONS
SETTING SCREENS
SUSTAINABLE SOLUTIONS
SETTING SCREENS
SUSTAINABLE SOLUTIONS
SETTING SCREENS
SUSTAINABLE SOLUTIONS
SETTING SCREENS
SUSTAINABLE SOLUTIONS
EcogeoSolar Hybrid System
SUSTAINABLE SOLUTIONS
The ultimate solution
Easy installation
Grid interaction modes
High configuration flexibility
Storage system included
Highest market efficiency 98,3 %
Highest HVAC market efficiency system. COP 4,9
SUSTAINABLE SOLUTIONS
PROJECTS: SMART GRID CITY
SUSTAINABLE SOLUTIONS
MF02 SMART GRID SYSTEM
SUSTAINABLE SOLUTIONS
SMART GRID CITY BARCELONA
SUSTAINABLE SOLUTIONS
A member of the melfosur group
www.melfosur.es
SUSTAINABLE SOLUTIONS