presentation: fibre channel connection and san connectivity · 1 1,2 1,4 1,6 1,8 2 700 1000 1300...
TRANSCRIPT
Copyright 2011 Fujitsu Technology Solutions
Fibre Channel Connection
and SAN Connectivity
Fibre channel on BS2000/OSD s series business servers
Copyright 2011 Fujitsu Technology Solutions
Fibre Channel
1
ESCON
FC
Every 2-3 years, doubling of server and disk subsystem performance.
Since the transition from Type 2 to Type S, nothing has happened in the I/O area!
Innovation Fibre Channel
high performance
low cost
The real innovation for BS2000 customers
Copyright 2011 Fujitsu Technology Solutions
BS2000 offering for S customers
Systematic implementation of our open system strategy
Hardware – SAN connection - openness
High-performance connection
Fibre Channel on /390 systems is a highlight for the S architecture and a
unique selling point
Real alternative to IBM’s FICON
not a “proprietary” connection, but standard technology
2
Copyright 2011 Fujitsu Technology Solutions
Mainframe features in the SAN
Customer benefits:
Up to 8 paths to a Device
Redundancy for failure scenarios
Dynamic load balance
One FC connection can be used for several guest systems (VM2000)
Efficient utilization of the HW resources by server and Storage subsystem
Such Features are standard for mainframe systems
– in open systems area not available yet
3
Copyright 2011 Fujitsu Technology Solutions
Innovation with BS2000/OSD
Fiber Channel -
High-end SAN-Connectivity
Unified infrastructure for storage (online
and near line) and communication
Simplified I/O-network
Reduction of physical connections
Integration into enterprise-wide SAN
concepts
High performance
4
Vast increase of efficiency with modern Fiber Channel Technology
for online and near line storage
BS2000/OSD Data Center
ETERNUS
Disk storage
system
ETERNUS CS
Virtual Tape
Appliance
Symmetrix V-Max
Disk storage
system
Scalar
Tape storage
system
HNC
High speed
net connect
SAN
Copyright 2011 Fujitsu Technology Solutions
BS2000/OSD V8.0 Online peripherals
5
ETERNUS
DX410, DX440
DX8400, DX8700
FibreCAT
CX500/700
CX3 / CX4
CLARiiON CX
(SQ und SX)
EMC DMX Series
800/801
1000/2000/3000
DMX3, DMX4,
V-Max
S Series
HNC V
SKP
3970
ESCON
Fibre Channel
SQ Series
SAS
RAID Disk
Subsystem JX40
ETERNUS CS
High End
LAN
Copyright 2011 Fujitsu Technology Solutions
ETERNUS CS with Fibre Channel connectivity
BS2000/OSD provide LTO technology with ETERNUS CS Model and
directly to the FC channel Scalar archive systems
S-Servers: … S145/S180, S155/S190, S165/S200, S175/S210
SX-Servers: . . SX100, … SX150, SX160
SQ-Server: SQ100, SQ200
Without data migration
Operation of virtual volumes in the ETERNUS CS at
Typ S Channel and FC with volume type “TAPE-C4”
identical internal volume format
Requirement: from BS2000/OSD-BC V5.0C
6
Copyright 2011 Fujitsu Technology Solutions
BS2000/OSD V8.0 Nearline peripherals
7
i500 i2000 I6000 10K LTO3 LTO4 LTO5
LTO3 LTO4
-
LTO3 LTO4 LTO5
LTO3 LTO4 LTO5
(Magstar)
S Series
SQ Series
Quantum Scalar
ROBAR
ETERNUS LT40
LTO2
LTO3
LTO4
ESCON
Fibre Channel
SCSI
SAS
ETERNUS CS
LAN
SQ200 mit LTO5 ab 2.Q.12
Copyright 2011 Fujitsu Technology Solutions
Scaling with 2 KB
8
IO-Zeiten (2K-Key; Random; 2KB)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
IO-Rate
Ze
it (
ms
)
ESCON
1 FC
2 FC
2 ESCON 6 ESCON4 ESCON
Highlights Fibre Channel versus ESCON
shortened I/O time
increased throughput: Factor 3.5 to 4.0
Copyright 2011 Fujitsu Technology Solutions
Scaling with 32 KB
9
IO-Zeiten (NK2; Random; 32KB)
0
0,5
1
1,5
2
2,5
3
400 800 1200 1600 2000 2400 2800 3200 3600 4000
IO-Rate
Ze
it (
ms
)
ESCON
1 FC
2 FC
4 ESCON2 ESCON 6 ESCON 8 ESCON 10 ESCON 12 ESCON
Highlights Fibre Channel versus ESCON
shortened I/O time
increased throughput: Factor 6 to 8, up to 96 MB/s
Copyright 2011 Fujitsu Technology Solutions
Typ-FC vs Typ-S: 2 KB blocksize, 100 % Read Hit
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
700 1000 1300 1600 1900 2200 2500 2800 3100 3400 3700 4000 4300 4600 4900 5200 5500 5800
IO-Rate
Tim
e (
ms
)
Typ-S 2K-Key
Typ-FC 2K-Key
Typ-S NK2
Typ-FC NK2
Scaling with 2 KB
10
Highlights Fibre Channel versus ESCON
shortened I/O time: from 0.5 to 0.2 ms
increased throughput: Factor 3.5 to 4.0
Copyright 2011 Fujitsu Technology Solutions
Scaling with 32 KB
11
Typ-FC vs. Typ-S: 32 KB blocksize, 100 % Read Hit
0
1
2
3
4
5
6
7
8
9
10
100 200 300 400 500 600 700 800 900100
0110
0120
0130
0140
0150
0160
0170
0180
0190
0200
0210
0220
0230
0240
0250
0260
0270
0280
0
IO-Rate
Tim
e (
ms
)
Typ-S 2K-Key
Typ-FC 2K-Key
Typ-S NK2
Typ-FC NK2
Highlights Fibre Channel versus ESCON
shortened I/O time
increased throughput: Factor 6 to 8, up to 96 MB/s
Copyright 2011 Fujitsu Technology Solutions
Value added of Fibre Channel technology
For high volumes of data and tight
backup times
Balanced system: Online / Nearline
For data backup, archiving and restore
Benefit against ESCON
TP mode: up to factor 4
Restore / backup time: up to factor 7
More performance with
Tuning measures in HSMS
Use of new LTO tape technology
Requests to use faster disk systems, the
use of PAV (Parallel Access Volume)
12
HSMS / Archive
FC:
80 - 90 MB/s
ESCON:
11 - 12 MB/s
BS2000/OSD Server S210
ETERNUS CS Symmetrix V Max
Copyright 2011 Fujitsu Technology Solutions
Advantages of FC over ESCON
Customer benefits:
Integration into SAN environment and for SAN consolidation
Integration into existing installations - Mainframe, Unix system, Win
Distance up to 10 km (up to 100 km with repeaters)
Improved performance and throughput for batch, OLTP and data backup
Large I/O bandwidth: measured data throughput up to 96 MB/s
Shorter disc storage I/O times: up to factor 3
Reduction backup time: up to factor 7
Cost saving: fewer connections in the server and disk storage subsystem
one FC connection replaces approx. four ESCON connections
FBA saves up to 30% capacity in the disk storage subsystem compared to CKD
13