presentation… hydronics ltd. family of products. camus hydronics is a world renowned manufacturer...
TRANSCRIPT
Presentation…
Hydronics Ltd.
Family of ProductsFamily of Products
CAMUS Hydronics is a world renowned manufacturer of Industrial,
Commercial and ResidentialBoilers and Water Heaters.
The CAMUS corporate head office,manufacturing plant and warehouse
are housed under one roof in amodern 68,000 square foot facility.
CAMUS products are constructedusing state of the art components
and high quality materials, engineeredto operate with maximum efficiency,
providing years of dependable service.
The CAMUS Product Development Teamis comprised of the very best engineersand hydronic specialists in the industry,
continually setting higher standardswith every new product release.
The CAMUS CERTIFIED Sealassures you that
RELIABILITYEFFICIENCY
andSERVICEABILITY
are built into every unit.
CAMUS Hydronics is also a manufacturerof replacement parts for
most copper finned water heatersand heating boilers as well as a
supplier of specialty HVAC products.
The CAMUS SERVICE LINEis open 24 hours a day
7 days a week!
Extremely Low NOx!
THE DYNAFLAME ISAVAILABLE IN CONDENSING,
NON-CONDENSING AND NEAR-CONDENSING MODELS WITH
CAPACITIES RANGING FROM500 UP TO 5,000 MBUTH!
Gas Fired Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply
Standard Features
85% Efficiency (non-condensing) & 95% (condensing)
Suitable for Category 1 Installation
All Bronze and Copper Water Surfaces
Range of Burner Modulation of 20 – 100% (condensing)
Range of Burner Modulation of 35 - 100% (non-condensing)
Single Point Input Adjustment for Controlling Air and Gas
1 to 1 Gas/Air Ratio for perfect modulation throughout
Extremely low NOx Emissions Exceeding Air Quality
Standards (less than 10 PPM)
Flow Switch
Standard Features(continued)
Very Small Footprint
Extremely Low Noise Level of Operation
Metal Fiber Knit Burner
Stainless Steel Outer Jacket & Combustion Chamber
Advanced Digital Control System with Pin Point Accuracy
Proven Hot Surface Ignition w/Soft Start for Rumble Free
Operation
Designed for Easy Access to Components for Maximum
Serviceability
Gasket-less Heat Exchanger Design
Standard Features(continued)
Maximum Allowable Working Pressure of 160 PSI
Maximum Operating Water temperature of 250°F
24 volt Circuit Breaker
Protective Air Filter
Very low Gas Pressure Operation (down to 2” pressure inlet)
Main Burner Test Firing Valve
Temperature and Pressure Gauge
Inspected and Tested to ASME Requirements
Pressure Relief Valve
Optional Equipment
Secondary Exchanger for Condensing
Operation at 95% Efficiency
High Gas Pressure Switch
Low Gas Pressure Switch
Normally Open Vent Valve
Low Water Cut-Off
Flame Failure Alarm
Pump Delay
Outdoor Installation
Cupro Nickel Heat Exchanger
(standard on models 3500 and up)
Cross Sectionals
Control Panel
Advanced digital display control w/pin point accuracy
Multi point diagnostic light package allowing forSimple troubleshooting
Three pre-set modes of operation: Mode 1 for heating,Mode 2 for domestic hot water heating and Mode 3 forOperation by a remote controller
Adjustable pump delay feature based on a Temp.,
difference between inlet and outlet temperatures.
Displays inlet temperature, outlet temperature,
temperature rise, error messages and run time
Flame failure signal
Optional tank mounted sensor used in conjunction
with inlet sensor for domestic hot water application
Many more built-in features
Venting
Venting
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply
For Hydronic Heating – Models MFH60, 100, 150, 200, 250, 300, 400, 500, 600
For Hot Water Supply – Models MFW60, 100, 150, 200, 250, 300, 400, 500, 600
Performance Highlights
Low NOx
Up to 85% Efficiency – Non-Condensing Mode
Durable Ceramic Burner Unaffected by High Temperatures
Vents up to 60 Feet Horizontally with 50 Feet of Air Intake Duct
Suitable for Use in Negative Pressure Environments
Input Range From 60 to 600 MBTUH
Complete Diagnostic Light Package
Up to 95% Efficiency – Condensing Mode
Easy Access for Inspection and Cleaning of Heat Exchanger Tubes
Durable Ceramic Fiber Refractory
Simple to Service With Easy Access to Burner and Fan
Control Panel
Accurate Proportional ControlW/2-Stage Option
Incorporates Auto Reset High
Limit and Operator
Three Modes of Operation:
Heating, DHW & Remote
Port for Optional Tank Sensor
Displays Inlet/Outlet Temperatures and Delta Temperature
* The Smartflame 780007 Control Panel
is Optional
Optional Pump Delay
Flame Failure Feature
Displays Total Run HRS
Molex® Harness Connection for Ease of Service
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
For Hydronic Heating – Models MFH800, 1000, 1200, 1400, 1600, 1800, 2000
For Hot Water Supply – Models MFW800, 1000, 1200, 1400, 1600, 1800, 2000
Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply
Low NOx
Up to 85% Efficiency – Non-Condensing Mode
Durable Ceramic Burner Unaffected by High Temperatures
Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct
Suitable for Use in Negative Pressure Environments
Input Range From 800 to 2000 MBTUH
Complete Diagnostic Light Package
Up to 95% Efficiency – Condensing Mode
Easy Access for Inspection and Cleaning of Heat Exchanger Tubes
Durable Ceramic Fiber Refractory
Simple to Service With Easy Access to Burner and Fan
Performance Highlights
Control Panel
Accurate Proportional Controlwith up to 4-Stage Option
Incorporates Auto Reset HighLimit and Operator
Port for Optional Tank Sensor
Displays Inlet/Outlet Temp’s
and Delta Temperature
Optional Pump Delay
Flame Failure Feature
Displays Total Run HRS
Molex® Harness Connection for Ease of Service
Weather Proof Enclosure
Fusible Link for Over-Voltage
Six Modes of Operation, forOutdoor Reset, Heating, DHWand Remote
Proven Field Performance
Firing Modes Available:
Models 800 - 1000 On / Off2-Stage
Models 1200 – 2000 On / Off2-Stage3-Stage
4-Stage
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
For Hydronic Heating – Models MFNH2000, 2500, 3000, 3500, 4000
For Hot Water Supply – Models MFNW2000, 2500, 3000, 3500, 4000
Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply
Low NOx
Up to 85% Efficiency – Non-Condensing Mode
Durable Ceramic Burner Unaffected by High Temperatures
Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct
Suitable for Use in Negative Pressure Environments
Input Range From 2000 to 4000 MBTUH
Complete Diagnostic Light Package
Up to 95% Efficiency – Condensing Mode
Easy Access for Inspection and Cleaning of Heat Exchanger Tubes
Durable Ceramic Fiber Refractory
Simple to Service With Easy Access to Burner and Fan
Accurate Proportional ControlWith Up To 4-Stage OptionIncorporates Auto Reset HighLimit and Operator
Port for Optional Tank Sensor
Displays Inlet/Outlet Temp’sAnd Delta Temperature
Optional Pump Delay
Flame Failure Feature
Displays Total Run HRS
Molex® Harness Connection for Ease of Service
Weather Proof Enclosure
Fusible Link for Over-Voltage
Six Modes of Operation, forOutdoor Reset, Heating, DHW, and Remote
Proven Field Performance
Firing Modes Available:Models 2000 - 4000 On / Off
2-Stage3-Stage4-Stage
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply
Gas Fired Commercial Copper Tube Boilers
For Hydronic Heating and Hot Water Supply
For Hydronic Heating – Models CFH450, 550, 650
For Hot Water Supply – Models CFW450, 550, 650
Low NOx
Up to 85% Efficiency
Minimum Standby Losses with EstimatedAverage AFUE Efficiencies of 82%
Durable Ceramic Burner not Affected by
Overheating
Vents up to 60 Feet Horizontally with 60 Feet ofIntake Air Duct
Suitable for Use in Negative Pressure Environments
Input Range From 450 to 650 MBTUH
Complete Diagnostic Light Package
Simple to Service With Easy Access to Burner
Performance Highlights
2-Stage Proportional Control
Incorporates Auto Reset High Limit & Operator
Three Modes of Operation – Heating, DHW and Remote
Port for Optional Tank Sensor
Flame Failure Feature
Displays Inlet/Outlet Temperatures and
Delta Temperature
Displays Total Run Hours
Snap on Molex Connection for Easy Service
Weather Proof Enclosure
Fusible Link for Over-Voltage
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
Gas Fired Commercial Copper Tube BoilersFor Hydronic Heating and Hot Water Supply
For Hydronic Heating – Models BFH480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950
For Hot Water Supply – Models BFW480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950
Diagnostic Lights Help Troubleshoot Over the Phone
Durable Stainless Steel Burners
Adaptable to Outdoor Use
Simple to Service
Slide Out Burner Tray
Easy Side Access for Inspection of Combustion Chamber
Optional Digital Temperature Control is Extremely Accurate to
Minimize Standby Losses From Temperature Overshoot
High Temperature Ceramic Fiber Tiles in Combustion Chamber
Very Smooth and Quiet Operation
Suitable for Venting in Low Ceiling Applications with Use of
Power Venter and Low Profile Hood
Efficiencies of up to 83%
Incorporates Auto Reset HighLimit & Operator
Three Modes of Operation:Heating, DHW and Remote
Port for Optional Tank Sensor
Flame Failure Feature
Displays Inlet/Outlet Temp’sAnd Delta Temperature
Displays Total Run Hours
Snap on Molex® ConnectionFor Easy Service
Fusible Link for Over-VoltageProtection
* The Smartflame 780007 Control PanelIs Optional
Venting
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
Gas Fired Commercial Copper Tube BoilersFor Hydronic Heating and Hot Water Supply
For Hydronic Heating – Models SFH420, 520, 600
For Hot Water Supply – Models SFW420, 520, 600
Temperature control is extremely accurate tominimize standby losses from temp. overshoot
Diagnostic lights help troubleshoot over the phone
Input Range From 420 to 600 MBTUH
Burner runs cool and requires minimum maintenance
Adaptable to outdoor use
Simple to service
Very smooth and quiet operation
Fully enclosed combustion chamber
Suitable for venting in low ceiling applicationsWith use of power venter and low profile hood
Efficiencies up to 83%
Incorporates Auto Reset High Limit & Operator
Three Modes of Operation – Heating, DHW and Remote
Port for Optional Tank Sensor
Flame Failure Feature
Displays Inlet/Outlet Temperatures and Delta Temperature
Displays Total Run Hours
Snap on Molex Connection for Easy Service
Weather Proof Enclosure
Fusible Link for Over-Voltage Protection
Venting
Specifications
DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE
Heat Exchanger Head Loss & Flow
Recovery Capacities
MBTU Input and Output
Dimensional Specifications
Shipping Weights
www.camus-hydronics.comwww.camus-hydronics.com
Standard Features
Constant or Outdoor Reset temperature control
Optional heating load matching software
Domestic target water temperature limit to prevent
boiler condensation or to maintain domestic hot water
heat exchanger temperature
Maximum target water temperature limit to prevent
individual boiler limit tripping
Warm weather shutdown of boilers and main pump(s)
Controls any type or combination of modulating & staging
boilers – 12 outputs per controller – each modulating boiler
uses 2 outputs, each staging boiler uses 1 output per stage;
each pump uses 1 output. Some possible controlconfigurations for a single controller application include:
- controls up to 6 modulating boilers- controls up to 5 modulating boilers + 2 main pumps- controls up to 4 modulating boilers
+ 2 single stage boilers + 2 main pumps- controls up to 3 modulating boilers + 3 two-stage boilers
Standard Features(CONTINUED)
Runtime based lead / lag control of boilers, regardless of type
Master – Slave arrangement allows for additional
controllers to be added to increase the boiler control
capability. In this manner, with 2 controllers, 24 outputs
are available (up to 12 mod boilers, or combination ofmod and staging boilers)
Totally custom firing sequences available to allow high
efficiency boilers to fire first followed by less efficient boilers
Runtime based lead / lag control of main system pumps,
comes with flow sensing & automatic lag pump switch-over
in case lead pump should fail
Standard Features(CONTINUED)
Lock & key(s) to prevent unauthorized editing of parameters
EMS (Energy Management System) interfaces:
- enable / disable of heating controller (EMS enables or
disables heating system
- remote set point control of heating system (EMS providesone control override (DO) and one 0-20ma signal (AO)to Stage-Mod to take full control of Stage-Mod target
temperature)
Web / LAN server interface allowing each controller tocommunicate to any PC web-browser application
Custom serial protocols available
Optional Features
Remote Set-point Option Allows EMS interfacing
to Stage-Mod
Web Server Option Web / LAN server module
for Stage-Mod
Customizing Options(s) Project specific customization
available on request
Add On Options
LCD Display
Power On
Outdoor Temperature
System Water Temperature
Target Water Temperature
Set Point
Ratio Setting
Throttling
Outdoor Start-up Temperature
System Water Temperature
Standard Features
Indoor / Outdoor Sensors are solid state and capable of maintaining accuracy at a maximum wire length of 4,000 feet of shielded cable
Power Relays are Socket - Mounted and replaceable on site
Control is equipped with Boiler Override and Boiler By-Pass Switches
Capable of Fully Modulating the Gas Input of the Boilers
Automatically shuts down the heating unts as a Preset Outdoor Temperature which is variable between 50 and 100° F
Can be mounted in an enclosure suitable for wall mounting
Has a Minimum Boiler Water Temperature Setting independent of and capable of Overriding the Scheduled Function. This setting is variable between 90 and 150°F
Standard Features (cont’d)
Allows for Automatic Switching of the Lead Boiler
LED liights on the front door panel to indicate a "Boiler in Fault" alarm
Control is equipped with Boiler Override and Boiler By-Pass Switches
All Boiler Status Information is accessible from a Remote Location via the CM8 Central Control Panel
Boiler Control communicates through the "Camus Communication Interface" to LonWorks, BACnet and other systems.
Thank-You!