presentation of mocktile rf testing
TRANSCRIPT
The anodes fanout
Picture not up-to-date, but: • The electrical connection are
done. • The SMA cables are attached to
all traces (except for one). • The device is ready to be
readout. • So far holding vacuum.
Visualisation
• The group of strips on the left is more uniform
• The worst performance of the right strip probably due to misalignment
Cavity resonance
• The device is 8.66+8.86in long, which correspond to fundamental mode at:
168MHz • The measurment show an
absorption due to it at: 175MHz
• This was also predicted by HFSS
Eshop testbench
A testbench of the anodes has been setup at the eshop to further investigate the anode stripline. • Cleaner strips. • Better interconnect.
Here cavity mode = 333MHz
Comparison of measurement
Red curve: eshop testbench Blue curves: mocktile Not sure where the real limitations are coming from yet.