presentation overview - · pdf filepresentation overview 1. ... noted manufacturer of turbine...
TRANSCRIPT
1
Presentation OverviewPresentation Overview
1.1. Who is Hoffer Flow Controls?Who is Hoffer Flow Controls?
2.2. Show me the money (benefits)!Show me the money (benefits)!
3.3. ArenAren’’t there other flowmeters that are t there other flowmeters that are
better?better?4.4.
How Hoffer flowmeters can help you.How Hoffer flowmeters can help you.
2
Hoffer has supplied flowmeters for Hoffer has supplied flowmeters for BOPBOP’’s.s.
In fact, we have supplied well over 100 meters for BOP’s alone!
3
Hoffer has supplied flowmeters for use Hoffer has supplied flowmeters for use on subsea on subsea ROVROV’’s.s.
Flowmeters monitor hydraulic fluid system performance
4
Hoffer has supplied subsea flowmeters for a wide Hoffer has supplied subsea flowmeters for a wide variety of variety of tooling skids.tooling skids.
Hydrate remediation skid
BOP Intervention Skid
5
Hoffer flowmeters are used onHoffer flowmeters are used on Drill ShipDrill Ship Pacific Santa Ana with Pacific Santa Ana with
ABSABS--CDS approvalCDS approval
6
Hoffer flowmeters are used for a Hoffer flowmeters are used for a variety of variety of topside topside of flow applications.of flow applications.
7
Why you Why you ““shouldshould”” consider using Hoffer consider using Hoffer turbine flowmeters!turbine flowmeters!
8
Hoffer Flow Controls
Providing flow solutions to industry for over 40 years.
Privately‐held corporation located in Elizabeth City, NC.
Noted manufacturer of turbine flowmeters for liquid, gas and cryogenic flow
measurement.
9
Hoffer Flow ControlsHoffer Flow Controls
Some of the major markets servedSome of the major markets served……..
Oil & Gas Upstream and DownstreamOil & Gas Upstream and Downstream
CryogenicsCryogenics
Pharmaceuticals & BiotechPharmaceuticals & Biotech
MilitaryMilitary
AerospaceAerospace
Power ProductionPower Production
10
Hoffer Flow ControlsHoffer Flow Controls
Recognized for being able to design and build Recognized for being able to design and build custom flow meters in a short time.custom flow meters in a short time.
Examples of custom design requirements Examples of custom design requirements include high pressure requirements (as much as include high pressure requirements (as much as
60,000 PSIG), exotic alloys, ultra60,000 PSIG), exotic alloys, ultra‐‐high velocity high velocity flow measurement applications (Mach 0.5) and flow measurement applications (Mach 0.5) and
designs for harsh environments (subsea to designs for harsh environments (subsea to 15,000 FT).15,000 FT).
11
Turbine Flow Meters
Turbine flow meters measure velocity.
They work well in clean, low to mid‐viscosity applications.
Liquid meters typically designed to measure up to 20 feet per second.
Gas meters are designed to measure velocities as high as 250 feet per second.
12
Meter Body Pickup Coil
Hangers or Integral Flow Straightener
Thru-Shaft w/Locknuts
Coil Riser
Deflector Cones
Flat-Bladed Turbine Rotor
Basic Principle of Operation Basic Principle of Operation
13
Turbine FlowmeterPerformance Characteristics
LIN
EA
RIT
Y
FLOW RANGE ATDESIGNATED LINEARITY
K-FACTOR
OUTPUT VOLTAGE (Mv)
OUTPUT FREQUENCY (Hz)
PRESSURE LOSS (PSID)
PR
ES
SU
RE
LO
SS
(P
SID
)
OU
TP
UT
FR
EQ
UE
NC
Y (
hZ
)
OU
TP
UT
VO
LTA
GE
(M
v)
K-F
AC
TO
R (
CY
C/G
AL
)
FLOW RATE
14
Basic Definitions
LINEARITY:
K-FACTOR:
REPEATABILITY:
A measure of the accuracy of the device which is the maximum percentage deviation from the average K-Factor.
The number of output pulses the flowmeter produces per engineering unit of the volume throughput.
A statement of the ability of a measuring device to display the same value of a measured variable under identical conditions.
15
Why use turbine meters?
16
Mini-Flowmeters for low flow
liquid and gas applications.
“Premier Natural Gas Series” for custody transfer of natural gas.
3A Certified Sanitary Flowmeters for food, beverage, pharmaceutical and
bio-tech.
HO Series with MS Flared
fittings commonly used
in industry.
Providing Providing ““Application SpecificApplication Specific”” flow solutions for our customers is the key.flow solutions for our customers is the key.
17
Turbine Meter Advantages Turbine Meter Advantages –– PerformancePerformance
High degree of accuracy High degree of accuracy (+/(+/‐‐.25% of reading) and .25% of reading) and
great repeatability (+/great repeatability (+/‐‐.1%).1%)
Suitable for Suitable for ““custodycustody””
transfertransfer
18
Turbine Meter Advantages Turbine Meter Advantages –– Response TimeResponse Time
Fast, dynamic Fast, dynamic
response response
timetime
Measured in milliseconds!Measured in milliseconds!
Commonly used for rocket Commonly used for rocket propulsion propulsion
19
Turbine Meter Advantages Turbine Meter Advantages –– Shock, vibration & temp extremesShock, vibration & temp extremes
We pWe pioneered the use of turbine ioneered the use of turbine
flowmeters on cryogenic delivery flowmeters on cryogenic delivery
trucks in the 1970trucks in the 1970’’ss
Suitable for installation on trucks Suitable for installation on trucks
subject to shock & vibration subject to shock & vibration
Subject to wide operating Subject to wide operating
temperature extremestemperature extremes
Our flow system is the Our flow system is the ““cash cash registerregister””
on many bulk delivery on many bulk delivery
cryogenic trucks domestically and cryogenic trucks domestically and
internationallyinternationally
20
Turbine Meter Advantages Turbine Meter Advantages –– ReliabilityReliability
Metering control fluid on a BOPMetering control fluid on a BOP
Hoffer replaced Hoffer replaced ““leakingleaking””
mag mag
metersmeters
High High ““internalinternal””
& & ““external external
pressurespressures””
21
Turbine Meter Advantages Turbine Meter Advantages –– Robust DesignRobust Design
Flowmeter Flowmeter ““internalsinternals””
designed designed
to meet to meet ““high high
shockshock””
and and
““vibrationvibration””
MIL MIL
standards for standards for
US Navy.US Navy.
For use on every For use on every ““classclass””
of of US Navy ships. Applications US Navy ships. Applications
include fuel measurement and include fuel measurement and
RO water systems (seawater). RO water systems (seawater).
22
Turbine Meter Advantages Turbine Meter Advantages Robust DesignRobust Design
FlowmeterFlowmeterInternalsInternals
Threaded InsertThreaded Insert
23
Turbine Meter Advantages Turbine Meter Advantages –– Wide RangeabilityWide Rangeability
Flowmeters can be configured to Flowmeters can be configured to provide repeatable flow ranges provide repeatable flow ranges
with up to 100:1 turndown ratios. with up to 100:1 turndown ratios.
24
Liquid Size SelectorFor
Standard HO Series Turbine FLowmeters
Liquid Size SelectorFor Standard HO Series Turbine Flowmeters
Flowmeter Size MAGNETIC PICKUP COIL MODULATED PICKUP COIL
DiameterDiameter(inches)(inches)
Linear RangeLinear Range(US GPM)(US GPM)
Linear RangeLinear Range(LPM)(LPM)
Repeatable Range(US GPM)
Repeatable RangeRepeatable Range(LPM)(LPM)
Linear RangeLinear Range(US GPM)(US GPM)
Linear RangeLinear Range(LPM)(LPM)
Repeatable Range
(US GPM)
Repeatable Repeatable RangeRange(LPM)(LPM)
1/4*1/4* .35.35--3.53.5 1.31.3--13.213.2 .25.25--4.54.5 .95.95--1717 .35.35--3.53.5 1.31.3--13.213.2 .0625.0625--4.54.5 .24.24--1717
3/8*3/8* .75.75--7.57.5 2.82.8--28.428.4 .3.3--99 1.11.1--3434 .75.75--7.57.5 2.82.8--28.428.4 .075.075--99 .28.28--3434
1/21/2 1.251.25--9.59.5 4.74.7--3636 .6.6--1212 2.32.3--4545 1.251.25--9.59.5 4.74.7--3636 .12.12--1212 .45.45--4545
5/85/8 1.751.75--1616 6.66.6--60.660.6 .9.9--2020 3.43.4--75.775.7 1.751.75--1616 6.66.6--60.660.6 .2.2--2020 .75.75--75.775.7
3/43/4 2.52.5--2929 9.59.5--110110 1.51.5--3535 5.75.7--132.5132.5 2.52.5--2929 9.59.5--110110 .35.35--3535 1.31.3--132.5132.5
1 4-60 15-227 2-75 7.6-284 4-60 15-227 .75-75 2.8-284
11--1/41/4 66--9393 2323--352352 33--115115 11.411.4--435435 66--9393 2323--352352 1.151.15--115115 4.354.35--435435
11--1/21/2 88--130130 30.330.3--492492 55--175175 1919--662662 88--130130 30.330.3--492492 1.751.75--175175 6.66.6--662662
22 1515--225225 56.856.8--852852 1111--275275 4242--10411041 1515--225225 56.856.8--852852 2.752.75--275275 10.410.4--10411041
22--1/21/2 2525--400400 9595--15141514 1515--500500 56.856.8--18931893 2525--400400 9595--15141514 55--500500 1919--18931893
33 4040--650650 151151--24602460 2020--800800 7676--30283028 4040--650650 151151--24602460 88--800800 30.330.3--30283028
44 7575--12501250 284284--47314731 5050--15001500 189189--56785678
MCP not recommended in 4MCP not recommended in 4”” and larger sizesand larger sizes
55 140140--20002000 530530--75707570 100100--25002500 379379--94639463
66 200200--29002900 757757--1097710977 125125--36003600 473473--1362613626
88 330330--52005200 12491249--1968219682 270270--64006400 10221022--2422424224
1010 650650--80008000 24602460--3028030280 540540--98009800 20442044--3709337093
1212 14001400--1200012000 52995299--4542045420 800800--1500015000 30283028--5677556775
NOTE: NOTE: Performance enhancement techniques are routinely applied to prodPerformance enhancement techniques are routinely applied to produce larger linear and usable flow ranges. uce larger linear and usable flow ranges. Consult with the applications group at Hoffer with your requiremConsult with the applications group at Hoffer with your requirements.ents.
25
Turbine flowmeters are highly “repeatable” (+/-.1%). “Smart” Electronics can correct for non-linearity of the flowmeter.
PLOT OF TURBINE FLOWMETER CALIBRATION“K-FACTORS” (pulses/gallon)
26
1% 10% 100%
Flow Rate
Accuracy
Percent of Reading
Percent of Full Scale Absolute Accuracy Becomes Worse with Decreased Flow
Linearity and repeatability are expressed in terms of Linearity and repeatability are expressed in terms of ““percent of readingpercent of reading”” rather than rather than ““percent of full scalepercent of full scale””
such as a differential pressure flowmeter.such as a differential pressure flowmeter.
Turbine Meter Advantages Turbine Meter Advantages –– Of Reading vs. Percent of Full ScaleOf Reading vs. Percent of Full Scale
27
All All ““turbine flowmetersturbine flowmeters””
are not created equal are not created equal --
Some are plastic
Some are Aluminum
Some are molded
There are many
differentdesigns of“Turbine meters”
28
Common Design Elements Common Design Elements –– ffor a or a
““high performance turbine flowmeterhigh performance turbine flowmeter””
29
Rotor Construction Rotor Construction –– Precision MachinedPrecision Machined
All Rotor assemblies are precision machined. All Rotor assemblies are precision machined.
Hoffer does not use cast rotors.Hoffer does not use cast rotors.
Cast rotors are Cast rotors are ““heavierheavier””
than rotors machined than rotors machined from solid bar stock. Heavier rotors mean slower from solid bar stock. Heavier rotors mean slower
dynamic response to changes in flow rates. dynamic response to changes in flow rates.
30
Rotor Construction Rotor Construction –– Rotor DesignRotor Design
Hoffer uses flat rather than curved blades Hoffer uses flat rather than curved blades on its rotorson its rotors
Curved blades produce a higher pressure Curved blades produce a higher pressure drop.drop.
31
Rotor Construction Rotor Construction –– Rotor DesignRotor Design
Machined rotors can be Machined rotors can be ““customizedcustomized””
with with thicker blades for use in abrasive servicesthicker blades for use in abrasive services
The blade The blade ““lengthlength””
may be adjusted to may be adjusted to accommodate larger particulate. This approach accommodate larger particulate. This approach
is commonly utilized in the design of our oil is commonly utilized in the design of our oil patch flowmeters. patch flowmeters.
32
Optimization of Optimization of ““flow rangeflow range”” -- Supplying various blade angles and rotor designsSupplying various blade angles and rotor designs
Hoffer provides four different blade angles (15, 20, 25 & 30 degree) for each size meter within our HO Gas
product line to optimize the ideal flow range selection.
The “steeper”
the blade angle; the lower the flow rate capability.
We offer “bladed”
and “rim”
type rotor assemblies. Rim rotors are typically specified for custody transfer
applications and produce more “pulses”
(better resolution).
33
Bladed Rotor AssemblyBladed Rotor AssemblyRim Rotor Assembly
34
In conclusion, you should consider using turbine flowmeters if…
Accuracy is important
You need a robust flowmeter
You require dynamic response to changes in flow conditions
You require a wide flow range
You have a specific “footprint”
(space) in which the flowmeter must fit
You want a flowmeter that is light in weight and easy to install
35
How can we help your company take advantage of our solutions?