presentation to 248 american chemical society national...

42
Measuring Bulk Fuel Velocity at the National Ignition Facility with Neutron Activation Presentation to 248 th American Chemical Society National Meeting August 10, 2014 Darren Bleuel

Upload: others

Post on 26-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Measuring Bulk Fuel Velocity at the National Ignition Facility with Neutron Activation

Presentation to 248th American Chemical Society National Meeting

August 10, 2014

Darren Bleuel

Page 2: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

NAD  Physics  Basis  Ac-va-on  Concept  

Four  energy  regions  of  interest:  

1-­‐10  MeV  (T-­‐T  /  D-­‐D  spectrum)  

10-­‐13  MeV  (DownscaGered)  

13-­‐15  MeV  (Primaries)  

15-­‐30  MeV  (Ter-aries)  

Yield  (n/  M

eV)  

Energy  (MeV)  

Neutron  Spectrum  

Neutron  energy  (MeV)  

115In(n,n’)  ⇒  115mIn    (t1/2=4.5  h)  93Nb(n,2n)  ⇒  92mNb  (t1/2=10  d)  90Zr(n,2n)  ⇒  89Zr    (t1/2=3.3  d)  63Cu(n,2n)  ⇒  62Cu    (t1/2=9.74  m)  12C(n,2n)  ⇒  11C    (t1/2=20  m)  

Cross  sec-o

n  (b)    

Ac-va-on  Foil  cross  sec-ons  

Yn =4πR2ANc

mfBR faNAεirrεdet < σ > [e−λ (Δtstart ) − e−λ (Δtend ) ]

14  MeV  n  

10  MeV  n  

HPGe  

Page 3: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

LLNL Nuclear Counting Facility in B151

3

Page 4: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

t1/2=4.5h  

t1/2=3.3d  t1/2=15h  

The  six  “flavors”  of  Neutron  Ac6va6on  

4  

DIM-­‐NAD  (DD)  

Snout-­‐NAD  (DD)  

Well-­‐NAD  (DT)  

Flange-­‐NAD  (DT)  

NAD20  (DT)  

(not  actual  loca-ons)  

In  

In  

Zr  

Zr  Zr  Zr  Zr  Zr  Zr  Zr  

Zr  Cu  

t1/2=4.5h  

t1/2=4.5h  

t1/2=3.3d  

t1/2=3.3d  t1/2=9.7m  

t1/2=3.3d  

Background  model  valida-on  (DT)  

Al   Zr  In  

Page 5: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

t1/2=4.5h  

t1/2=3.3d  t1/2=15h  

The  six  “flavors”  of  Neutron  Ac6va6on  

5  

DIM-­‐NAD  (DD)  

Snout-­‐NAD  (DD)  

Well-­‐NAD  (DT)  

Flange-­‐NAD  (DT)  

NAD20  (DT)  

(not  actual  loca-ons)  

In  

In  

Zr  

Zr  Zr  Zr  Zr  Zr  Zr  Zr  

Zr  Cu  

t1/2=4.5h  

t1/2=4.5h  

t1/2=3.3d  

t1/2=3.3d  t1/2=9.7m  

t1/2=3.3d  

Background  model  valida-on  (DT)  

Al   Zr  In  

Page 6: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

The  six  “flavors”  of  Neutron  Ac6va6on  

6  

Flange-­‐NAD  (DT)  

(not  actual  loca-ons)  

Zr  Zr  Zr  Zr  Zr  Zr  Zr  

t1/2=3.3d  

Page 7: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD Overview

7

•   Zirconium  samples  mounted  outside  9-­‐16  ports  around  target  chamber.  

•   Inten-on  is  to  measure  yield  anisotropy  to  <2-­‐5%  precision  by  taking  in  ra-o  to  isotropic  shot.  

(not  actual  loca-ons)  n  

n  

Lead  Shield  

Detector  

10  samples  

RY  (Ω)=  

Page 8: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Double ratio to minimize uncertainties

8

Take  ra-o  of  one  flange  posi-on  to  another  (Well-­‐NAD)  and  normalize  to  an  isotropic  shot  (exploding  pusher).    All  systema-c  errors  are  eliminated.  

Note:  <σ>  does  not  cancel  in  the  case  of  a  “bulk  fuel  velocity.”  

Y(Ω2)  

Y(Ω1)  Shot  A:  “layered”  

Shot  B:  “exploding  pusher”  (isotropic)  

ΔρR = − ADTσ scatter

ln RSA( ) This  “double  ra-o”  of  specific  ac-vi-es  is  related  to  the  areal  density  differences  of  the  fuel.  

RSA =YA (Ω1) /YA (Ω2 )YB (Ω1) /YB (Ω2 )

=mA2mB2

mA1mB1

"

#$

%

&'AA10

AA20

"

#$

%

&'AB20

AB10

"

#$

%

&'

Page 9: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD locations

9

New FNAD locations (blue) were added after Feb 2012.  

Page 10: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD locations

10

Activity ratios measured at 17 locations  

Page 11: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD locations

11

Fit to low-order spherical harmonics  

Activity ratios measured at 17 locations  

Page 12: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD is sensitive to both ρR and core velocity along a given line of sight.

12

90Zr  and  39K  σ-­‐(n,2n)  

µ0=14.07  MeV,  σ=0.150  MeV  

nToF  and  MRS  yields  are  inde-­‐pendent  of  velocity.  Peak  shil  independently  measures  velocity.  

Velocity  

ΔρR  

Page 13: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

How to calibrate when the measurements are on the “calibration” shots?

13

u

Ω2

Ω1

A0

A0=εε1+α⋅ Ω̂

1+α⋅ Ω̂

#

$%

&

'(

Ω2

Ω1 u ε2 ε1

A2 A1

u

NIF  Chamber  In  principle…  •  12  calibra-on  (Expl.  Push.)  shots  •  x  17  zirconium  ac-va-on  measurements  •  =  204  datapoints  

•  17  irradia-on  efficiencies    •  +  3  velocity  vectors  x  12  shots  •  =  53  unknowns  

RSA =YA (Ω1) /YA (Ω2 )YB (Ω1) /YB (Ω2 )

=mA2mB2

mA1mB1

"

#$

%

&'AA10

AA20

"

#$

%

&'AB20

AB10

"

#$

%

&'

Assumed  isotropic!  

Can  a  global  fit  to  all  calibra-on  shots  give  us  the  efficiencies  despite  velocity  effects?  

α =3.2%

100km / s

Page 14: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

How to calibrate when the measurements are on the “calibration” shots?

14

u

Ω2

Ω1

A0

A0=εε1+α⋅ Ω̂

1+α⋅ Ω̂

#

$%

&

'(

Ω2

Ω1 u ε2 ε1

A2 A1

u

NIF  Chamber  

RSA =YA (Ω1) /YA (Ω2 )YB (Ω1) /YB (Ω2 )

=mA2mB2

mA1mB1

"

#$

%

&'AA10

AA20

"

#$

%

&'AB20

AB10

"

#$

%

&'

Assumed  isotropic!  

If  we  get  clever…  

A0

A0=εε1+α⋅ Ω̂ − Ω̂( )+O(α 2 )( )Ω2 Ω1

ε2 ε1

A2 A1

u -

A0A0

A0A0=ε εε ε

1+α⋅ Ω̂ − Ω̂ + Ω̂ − Ω̂( )+O(α 2 )( )Ω2 Ω1

ε2 ε1

A2 A1

u A4 A3 ε3

ε4 Ω4 Ω3

Ω3

Ω4

We  found  six  four-­‐vector  combi-­‐na-ons  which  sum  to  <10%,  including  every  FNAD  loca-on.    Six  constraints  were  added  to  our  global  fit,  elimina-ng  velocity  bias.  

Page 15: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

How to calibrate when the measurements are on the “calibration” shots?

15

Shot  #  

Low  velocity  High  velocity  

Page 16: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Core Velocity Correlates Strongly with Drive Asymmetry N101212-001 exploding pusher (direct drive)

16

Q35T  

Q35B  

Core velocity fit!!186±20 km/s! θ0=75°φ0=220°!

N101212-001 Flange-NAD!

Q35T  

Q35B  

Drive distortion (Hydra postshot)!

Core fuel velocity correlates with drive distortion, Doppler-shifting neutron spectrum, increasing activation along velocity axis.  

North!pole!

South!pole!

Page 17: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120217-­‐001  Flange-­‐NAD    example  of  MRS  peak  shi8  predic9on  from  FNAD  data  set  

Author—Yeamans 17 NIF-0000-00000s2.ppt

188±47 km/s!θ0=98°φ0=322°!dropped 22T/22B!

χ2:  9.20  (ν=13)  p-­‐value:  0.24    

MRS peak upshifted 113±16 keV!FNAD predicts 98 ± 13 keV upshift!

MRS has measured the DT peak energy shift predicted from the FNAD fit to within the known errors on every exploding pusher where MRS ran in medium-resolution mode and yield was sufficient for FNAD performance."

Page 18: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N101212-001!!186±20 km/s! θ0=75°φ0=220°!

Flange-NAD Measured Core Velocities Exploding Pushers with Drive Asymmetries normalized to N120721-001 (velocity corrected)

18

Q22T  

Q22B  

165±33 km/s!θ0=86°φ0=320°!

N120217-001!

N120331-002!135±40 km/s!θ0=99°φ0=244°!

Q43T  

Q43B  

Q35T  

Q35B  

N101030-002!!129±36 km/s! θ0=79°φ0=144°!

Q41T  

Page 19: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD Measured Core Velocities Exploding Pushers with Target Alignment Problems normalized to N120721-001 (velocity corrected)

19

100±40 km/s!θ0=88°φ0=162°!

Page 20: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Observed velocities on all twelve exploding pusher shots

20

Page 21: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Conclusions

21

•  Ac-va-on  provides  an  accurate  DT  yield  measurement  at  the  NIF.    •  Flange-­‐NAD  can  provide  a  high-­‐precision  measure  of  yield  anisotropy  and  bulk  

velocity.  

•  Making  a  measurement  on  a  calibra-on  shot  is  tricky,  but  not  impossible  when  you  have  clever  post-­‐docs.  

•  Measured  bulk  fuel  veloci-es  are  as  high  as  200  km/s,  correla-ng  with  laser  drive  asymmetries  and  misaligned  capsules.  

Page 22: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

LLNL •  Lee Bernstein •  Rich Bionta •  Jac Caggiano •  Charlie Cerjan •  Owen Drury •  Chris Hagmann •  Ed Hartouni •  Robert Hatarik •  Steve Hatchett •  Hesham Khater •  Joe Kilkenny •  Kenn Knittel •  Sebastien Le Pape •  Andy Mackinnon •  Jim McNaney •  Ken Moody •  Mike Moran •  Dave Munro •  Dieter Schneider •  Dawn Shaughnessy •  Charles Yeamans •  Rich Zacharias

UCB •  Brian Daub •  Bethany Goldblum

LLE •  Tim Duffy •  Vladimir Glebov •  Jim Knauer •  Craig Sangster OHIO •  Carl Brune SNL •  Gary Cooper •  Ray Leeper •  Carlos Ruiz

LLNL NCF: •  Bryan Bandong •  Cindy Conrado •  Phil Torretto •  Todd Wooddy MIT •  Dan Casey •  Johan Frenje •  Maria Gatu Johnson SUNY-Geneseo •  Cassie Brown •  Steve Padalino

LMJ •  Jean-Luc Bourgade

Page 23: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Extra  Slides  

Page 24: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Are  the  varia6ons  in  layered  cryo  shots  real  or  sta6s6cal?  minimum  yield  3e13  and  Flange-­‐NAD  diagnos9c  success  required  

Author—Yeamans 24

FNAD  loca-on  

χ2:  513  (ν=180)  p-­‐value:  1    

Page 25: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Exploding  Pusher  Shots,  velocity-­‐corrected  minimum  yield  3e13  and  Flange-­‐NAD  diagnos9c  success  required  

Author—Yeamans 25

FNAD  loca-on  

152  data  points,  p=0.52.  Instrument  response  is  demonstrated.  

Page 26: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

“Layered-cryo” w/ hohlraum (indirect drive) vs. “Exploding pusher” (direct drive)

26

“Layered-­‐Cryo”   “Exploding  Pusher”  

Simple  direct  drive  targets  

DT Gas

Wall explodes driving shock into DT

Laser beams

Hot  core,  ‘point’  source  of  neutrons  +  soU  x-­‐rays  

n14MeV

•  Laser energy produces ~ 10 keV electrons: heats thin Si capsule wall •  Low ρR (no n scatter) •  Isotropic •  Yield up to 5x1015 n

•  Laser energy produces ~300 eV x-rays in hohlraum “can,” heating CH or Be capsule wall •  Cryogenic DT “layered” fuel shell with gas interior •  “Hot spot” ignites high ρR layer burn •  Yield up to 1019 n

CH or Be ablator shells

solid cryo DT layer

DT gas

Cryogenic, x-ray driven, layered targets

Page 27: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD needs calibration to low-velocity, high-yield exploding pusher

27

Most low-velocity shots are low yield. N111121 used as calibration for 10-location FNAD.  

nToF  equator-­‐alcove  peak  -me  shil  ΔE  (keV

)  

Calibra-on  for  10-­‐port  FNAD  

Calibra-on  for  17-­‐port  FNAD  (aler  velocity  correc-on)  

<1014n  

}    low  velocity?  

Exploding  pusher  shots  

Courtesy:  Jim

 Knaur  

Page 28: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Core velocities for nTOF LOS"

Shot   Core  Velocity  

Magnitude  (km/s)  

Polar  angle  (°)  

Azimuthal  angle  (°)  

N110603   132   115   324  N110617   82   116   229  N110618   31   111   200  N111114   187   40   247  N111121     39   39   281  N120217   193   120   319  N120331   129   123   229  

Derived  core  velocity  vectors  for  exploding  pushers  

FNADS  165km/s  (86,  319)  

162km/s  (112,  227)  

Courtesy:  Jim

 Macnane

y  

Page 29: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

Flange-NAD results N120808-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 29

Page 30: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120802-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 30

Page 31: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120720-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 31

Page 32: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120716-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 32

Page 33: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120626-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 33

Page 34: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120422-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 34

Page 35: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120417-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 35

Page 36: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120412-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 36

Page 37: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120405-003 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 37

Page 38: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120321-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 38

Page 39: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120316-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 39

Page 40: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120219-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 40

Page 41: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120213-001 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 41

Page 42: Presentation to 248 American Chemical Society National ...bang.berkeley.edu/wp-content/uploads/Bleuel.pdf · Presentation to 248th American Chemical Society National Meeting August

N120205-002 normalized to N120721-001 velocity-corrected

Author—Yeamans, Aug 2012 42