pressure drop in reactors isothermal reactor design – part 2

Click here to load reader

Upload: wilfred-rich

Post on 13-Dec-2015

216 views

Category:

Documents


1 download

TRANSCRIPT

  • Slide 1

Pressure Drop In Reactors Isothermal Reactor Design Part 2 Slide 2 Design a PBR mole balance rate laws stoichiometry combination In case of 2nd order rxn, gas phase, isothermal Need to relate pressure drop to catalyst weight (in order to determine conversion) Slide 3 = pressure (kPa) = inlet pressure (kPa) = temperature (K) = inlet temperature (K) = porosity = volume of void = void fraction = volume of solid total bed volume total bed volume = cross sectional area (m 2 ) =diameter of particle in the bed, ft (m) =viscosity of gas passing through the bed, (kg/m.s) =length down the packed bed of pipe, ft (m) =superficial velocity = volumetric flow cross-sectional area of pipe (m/s) =gas density (kg/m 3 ) = solid density (kg/m 3 ) = inlet gas density = = superficial mass velocity, (kg/m 2.s) Design a PBR Ergun equation Slide 4 For isothermal operation, we have two sets of equation with two unknowns, X & P (1) (2) Special case: if =0, an analytical solution to second equation is obtained as follows Design a PBR Used only when =0 Slide 5 Design a PBR mole balance rate laws stoichiometry Combination Solve In case of 2nd order rxn, gas phase, isothermal When =0 By integration; Slide 6 Solving for conversion gives: Solving for catalyst weight, Design a PBR Slide 7 For gas phase reactions, as the pressure drop increases, the concentration decreases, resulting in a decreased rate of reaction, hence a lower conversion when compared to a reactor without a pressure drop. W, P, P W, P, C A P, P, C A, -r A W, X Slide 8 Effect of pressure drop on the conversion profile Consider a packed bed column with a second order reaction is taking place in 20 meters of a 1 schedule 40 pipe packed with catalyst. 2A B + C The following data are given: Inlet pressure, P 0 = 10 atm=1013 kPa Entering flowrate, v 0 = 7.15 m 3 /h Catalyst pellet size, D p = 0.006 m Solid catalyst density: c = 1923 kg/m 3 Cross sectional area of 1 -in schedule 40 pipe: A C =0.0013 m 2 Pressure drop parameter, 0 = 25.8 kPa/m Reactor length, L = 20 m Void fraction = 45% (a) Calculate the conversion in the absence of pressure drop. (b) Calculate the conversion accounting for pressure drop. (c) What is conversion in part (b) if the catalyst particle diameter were doubled. The entering concentration of A is 0.1 kmol/m 3 and the specific reaction rate is. Slide 9 (a) Conversion for P = 0 = 0 thus, [Volume of catalyst] x [catalyst density] Effect of pressure drop on the conversion profile Slide 10 (b) Conversion with pressure drop Effect of pressure drop on the conversion profile Slide 11 (c) Conversion when catalyst diameter were doubled. (increase by a factor of 2, ) From, thus Effect of pressure drop on the conversion profile dominant Slide 12 (c) Conversion when catalyst diameter were doubled. Thus, Conversion increases from 0.693 to 0.774 by increasing catalyst diameter by a factor of 2. Effect of pressure drop on the conversion profile Increasing particle size decrease the pressure drop parameter, increase conversion & reaction rate