price list 2017 - ciat

60
Price List 2017 Domestic and Light Commercial Product Range

Upload: others

Post on 31-Oct-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Price List 2017 - CIAT

Price List 2017

Domestic and Light CommercialProduct Range

Page 2: Price List 2017 - CIAT

2

A leader in Cooling, Heating and Indoor Air Quality

ContentsMAMBO - Universal air conditioner ......................................................................................................................................................... 6MAMBO - Console air conditioner ........................................................................................................................................................... 8STELLA - High-wall air conditioner ............................................................................................................................................................ 9SALSA - Cassette air conditioner ............................................................................................................................................................. 10TWIST - Ducted air conditioner .............................................................................................................................................................. 12Multi-split system - Outdoor units ......................................................................................................................................................... 14Multi-split system - Indoor units ............................................................................................................................................................ 15Multi-split system - possible system combinations ................................................................................................................................ 16

EREBA - Reversible heat pump ............................................................................................................................................................... 17EREBA performance tables ..................................................................................................................................................................... 18

GEOCIAT Power - Water-to-water heat pump ........................................................................................................................................ 21GEOCIAT Power performance tables ...................................................................................................................................................... 22GEOCIAT Access - Geothermal heat pump ............................................................................................................................................. 23GEOCIAT Access accessories ................................................................................................................................................................... 24GEOCIAT Access performance tables ...................................................................................................................................................... 24

AQUACIAT Caleo - Air-to-water heat pump ............................................................................................................................................ 25AQUACIAT Caleo performance tables ..................................................................................................................................................... 26AQUACIAT - Air-cooled liquid chillers ..................................................................................................................................................... 27AQUACIAT cooling only accessories........................................................................................................................................................ 28AQUACIAT liquid chiller performance table ............................................................................................................................................ 29AQUACIAT - Air-cooled heat pumps ....................................................................................................................................................... 30AQUACIAT heat pump accessories ......................................................................................................................................................... 31AQUACIAT heat pump performance tables ............................................................................................................................................ 32

COADIS LINE 600 - Cassette fan coil unit ................................................................................................................................................ 36COADIS LINE 900 - Cassette fan coil unit ................................................................................................................................................ 37COMFORT LINE - Ducted type fan coil .................................................................................................................................................... 38COMFORT LINE available options ........................................................................................................................................................... 39MAJOR LINE CV/CH - Cabinet unit .......................................................................................................................................................... 40MAJOR LINE NCV/NCH - Concealed unit ................................................................................................................................................ 41MAJOR LINE - Cabinet and concealed unit options ................................................................................................................................ 42

FLOWAY ACCESS - Air handling unit ........................................................................................................................................................ 43FLOWAY ACCESS - Air handling unit accessories ..................................................................................................................................... 44FLOWAY CLASSIC - Air handling unit with rotary heat exchanger ........................................................................................................... 45FLOWAY CLASSIC air handling unit with rotary heat exchanger accessories .......................................................................................... 46FLOWAY CLASSIC - Air handling unit with plate heat exchanger ............................................................................................................ 47FLOWAY CLASSIC air handling unit with plate heat exchanger accessories ............................................................................................ 48FLOWAY VERTICAL - Air handling unit .................................................................................................................................................... 49FLOWAY CEILING - Air handling unit ....................................................................................................................................................... 50HELIOTHERME 4000 - Air heater/chiller ................................................................................................................................................. 51

SPACE - Packaged unit ............................................................................................................................................................................ 52SPACE packaged unit options and accessories ....................................................................................................................................... 53

Air product range of equipment ............................................................................................................................................................. 54Chiller and heat pump range of equipment ........................................................................................................................................... 55

Toshiba range of products and services ................................................................................................................................................. 57

Page 3: Price List 2017 - CIAT

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

3

CIAT GROUP is a leading European manufacturer of a wide range of climate control products. Founded in 1934 we now supply to over 50 countries worldwide. Following integration into United Technologies Corporation, CIAT UK operates alongside Toshiba Air Conditioning.

Together our vision is to be the UK’s No. 1 supplier of technologically innovative, energy-efficient, environmentally-friendly HVAC equipment, combined with a first class level of customer support.

• Cutting-edge technology backed by a significant R&D programme.• Industrial excellence utilising the latest manufacturing processes.• Partnership programme to achieve excellence within our field. • Huge investment in the AHU production Airside Excellence Centre.• One of the largest HVAC innovation centres in Europe.• Product performance levels are validated by experts in our own test rooms.

We offer our customers full support from our engineers to back our supply of exceptional products. From design and specification, through installation and commissioning, control integration and maintenance we work with you to form a real partnership.

Page 4: Price List 2017 - CIAT

A leader in Cooling, Heating and Indoor Air Quality

4

The new CIAT Centre of Excellence includes two research and development facilities and test laboratories, which focus on product innovation to shorten new product development time scales and improve energy performance and user comfort. The R&D investment is part of more than $40m that UTC has invested at Culoz and Montluel, since the acquisition in 2015.

The factory in Montluel houses a Centre of Excellence for chillers and heat pumps. It supports chiller innovation and production, with a focus on new generation, environmentally-responsible refrigerants, with Culoz supporting further development of the new AHU range introduced during 2016.

The strategic move allows us to strengthen our heating, ventilating and air conditioning range, as well as our competitiveness and ability to innovate. The significant investment in the Culoz and Montluel sites complement each other and support production and design, allowing further improvement of our products and our ability to serve our customers.

Sustainability at the heart of what we doBoth Centre of Excellence sites recently underwent industrial transformations to support the company’s focus on sustainable innovation.

“The environmental impact was an important consideration of the site transformation, as we no longer use fossil energy thanks to a biomass-boiler heating system with advanced filters. The site also reduced water consumption by 40% while achieving a waste recycling rate of 75%.”

CIAT Centre of Excellence

Page 5: Price List 2017 - CIAT

5

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

Inverter single- and multi-split units

Controlled comfort in each roomThe split-system range is the ideal solution for residential and commercial applications where it is necessary to have total control of the indoor temperature. This new range of air conditioners offers a large operating range from -15°C to 46°C for improved comfort both in summer and winter. The large choice of indoor units ensures the best solution is available for each outdoor unit.

Many possible applicationsWith the split-system range of units, it’s possible to connect up to 5 indoor units to one single outdoor unit. Different indoor units can be connect to meet any requirement: high-wall units, console units, cassette units or ducted units. The multi-split range offers an ideal and totally flexible solution.

Page 6: Price List 2017 - CIAT

6

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

MAMBOUniversal air conditioner

• Infra-red controller as standard (wired available).• Full Wi-Fi compatibility.• Can be installed vertically or horizontally.• Fresh air connection.• Easy access from inside the grille.• 3D air flow meaning air intake from bottom or rear.

Inverter - R410AModel MAMBO

Ceiling 18HVMAMBO

Ceiling 24HVMAMBO

Ceiling 36HVMAMBO

Ceiling 36HVTIndoor unit 42HU18VSC 42HU24VSC 42HU36VSC 42HU36VSCOutdoor unit 38HU18VSC 38HU24VSC 38HU36VSC 38HU36VTCCooling capacity Min./nom./max. kW 2.00/5.00/5.50 2.50/7.03/8.00 4.40/10.40/11.00 4.00/10.40/11.40Heating capacity* Min./nom./max. kW 2.00/5.50/6.00 2.50/7.30/8.50 3.70/11.90/13.80 2.90/11.90/14.50

@ -7°C kW 4.00 5.30 9.80 9.70@ -10°C kW 4.00 5.50 8.40 8.30@ -15°C kW 3.00 4.90 8.20 8.20

P design capacity cooling kW 5.00 7.03 10.40 10.40P design capacity heating Warmer/average kW 4.00/5.00 5.20/7.80 10.20/10.60 10.30/10.40Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24 -15~24SEER W/W 5.9 5.8 6.3 6.3SCOP Warmer/average W/W 4.1/5.3 4.0/4.8 4.0/5.1 4.0/5.1Energy label SEER A+ A+ A++ A++

SCOP warmer/average A+/A+++ A+/A++ A+/A+++ A+/A+++Yearly energy consumption kWh 298/1470/1466 424/1820/2373 576/3561/2922 575/3599/2874EER/COP W/W 2.8/4.0 2.9/3.3 2.6/3.7 2.8/3.7Rated current A 11 16 23 12Rated input kW 2.53 3.68 4.80 4.80Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50Refrigerant amount R410A kg 1.70 2.05 3.65 3.65Liquid side - gas side inch 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/30 3/40 3/50 3/50

Max. height difference m 20 20 25 25Additional charge g/m 15 30 30 30

Indoor unit 42HU18VSC 42HU24VSC 42HU36VSC 42HU36VTCSound power level** dB(A) 58 65 65 65Sound pressure level** High/med./low dB(A) 45/42/39 50/47/41 55/51/46 55/51/46Air flow High/med./low m3/h 900/790/670 1150/1040/790 2000/1700/1350 2000/1700/1350Weight kg 27.0/32.0 27.0/32.0 38.0/44.0 38.0/44.0Dimension W x D x H mm 1068 x 675 x 235 1068 x 675 x 235 1650 x 675 x 235 1650 x 675 x 235Outdoor unit 38HU18VSC 38HU24VSC 38HU36VSC 38HU36VTCSound power level** dB(A) 65 69 70 70Sound pressure level** dB(A) 57 61 64 64Air flow m3/h 2100 2700 4150 4150Weight kg 38.0/40.6 50/54.5 70.5/76.1 85.3/91Dimension W x D x H mm 800 x 333 x 555 845 x 363 x 702 946 x 410 x 810 946 x 410 x 811System retail price £ 1,013 1,397 2,218 2,385* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

AccessoriesDescription Part Number Price, £Wired remote control for LC range - KJR-12- G2 7511630 73Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364

Page 7: Price List 2017 - CIAT

7

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

MAMBOUniversal air conditioner

Inverter - R410AModel MAMBO

Ceiling 48HVMAMBO

Ceiling 48HVTMAMBO

Ceiling 60HVTIndoor unit 42HU48VSC 42HU48VSC 42HU60VSCOutdoor unit 38HU48VSC 38HU48VTC 38HU60VTCCooling capacity Min./nom./max. kW 4.80/13.60/14.00 4.80/13.60/14.00 5.40/15.50/16.00Heating capacity* Min./nom./max. kW 5.40/15.50/16.00 5.40/15.50/16.00 4.30/17.50/18.50

@ -7°C kW 11.30 11.10 11.50@ -10°C kW 10.80 10.50 11.10@ -15°C kW 9.40 8.60 9.90

P design capacity cooling kW 13.60 13.60 15.50P design capacity heating Warmer/average kW 10.60/11.90 11.30/12.10 11.80/11.60Temperature range Cooling °C -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24SEER W/W 5.9 5.8 5.8SCOP Warmer/average W/W 4.0/5.3 4.0/5.3 4.1/5.1Energy label SEER A+ A+ A+

SCOP warmer/average A+/A+++ A+/A+++ A+/A+++Yearly energy consumption kWh 810/3718/3167 815/3954/3179 938/4011/3173EER/COP W/W 2.4/2.9 2.4/3.0 2.5/3.1Rated current A 26.5 13 14Rated input kW 6.10 6.10 7.50Power supply V/ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50Refrigerant amount R410A kg 4.00 4.00 4.30Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/50 3/50 3/50

Max. height difference m 25 25 25Additional charge g/m 30 30 30

Indoor unit 42HU48VSC 42HU48VTC 42HU60VTCSound power level** dB(A) 69 69 73Sound pressure level** High/med./low dB(A) 55/51/46 55/51/46 56/51/47Air flow High/med./low m3/h 2100/1700/1500 2100/1700/1500 2250/1900/1500Weight kg 38.2/44.6 38.2/44.6 40.5/47Dimension W x D x H mm 1650 x 675 x 235 1650 x 675 x 235 1650 x 675 x 235Outdoor unit 38HU48VSC 38HU48VTC 38HU60VTCSound power level** dB(A) 75 75 77Sound pressure level** dB(A) 64 64 64Air flow m3/h 6800 6800 7000Weight kg 95.1/108.4 108.1/121.2 112.8/126Dimension W x D x H mm 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333System retail price £ 2,631 2,660 2,728* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

All split-system unit ratings are based on the following conditions:Cooling capacities: Indoor air temperature 27°C (DB)/19°C (WB) - Outdoor air temperature 35°C (DB)/24°C (WB)Heating capacities: Indoor air temperature 20°C (DB)/15°C (WB) - Outdoor air temperature 7°C (DB)/6°C (WB)

Page 8: Price List 2017 - CIAT

8

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

MAMBOConsole air conditioner

• Infra-red controller as standard (wired available).• Full Wi-Fi compatibility.• Optional ‘follow me’ function.• Compact design.• Optimised air distribution.• Stylish and lightweight.

Inverter - R410AModel MAMBO

Console 9HVMAMBO

Console 12HVMAMBO

Console 18HVIndoor unit 42HC09VSC 42HC12VSC 42HC18VSCOutdoor unit 38HU09VSC 38HU12VSC 38HU18VSCCooling capacity Min./nom./max. kW 0.90/2.60/3.20 1.00/3.52/3.50 2.00/4.40/4.60Heating capacity* Min./nom./max. kW 0.80/2.90/3.70 1.00/3.70/4.00 2.00/5.40/5.50

@ -7°C kW 2.70 2.80 3.30@ -10°C kW 2.40 2.60 3.30@ -15°C kW 2.10 2.40 2.20

P design capacity cooling kW 3.00 4.00 4.00P design capacity heating Warmer/average kW 2.30/2.50 2.90/3.60 3.00/4.10Temperature range Cooling °C -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24SEER W/W 6.1 5.9 6.1 SCOP Warmer/average W/W 4.0/5.3 4.0/4.9 4.0/5.3Energy label SEER A++ A+ A++

SCOP warmer/average A+/A+++ A+/A++ A+/A+++Yearly energy consumption kWh 151/805/686 207/1016/1072 252/1048/1124EER/COP W/W 3.1/3.4 3.0/3.5 2.7/2.8Rated current A 10 10 11Rated input kW 2.30 2.30 2.53Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 0.28 1.05 1.70Liquid side - gas side inch 1/4 - 3/8 1/4 - 3/8 1/4 - 1/2Standard piping length Min./max. piping length m 3/20 3/25 3/30

Max. height difference m 8 10 20Additional charge g/m 15 15 15

Indoor unit 42HC09VSC 42HC12VSC 42HC18VSCSound power level** dB(A) 60 60 60Sound pressure level** High/med./low dB(A) 43/39/34 45/43/38 46/44/42Air flow High/med./low m3/h 460/400/360 530/480/360 530/470/430Weight kg 13.5/18.0 15.0/19.5 15.0/19.5Dimension W x D x H mm 700 x 600 x 210 700 x 600 x 210 700 x 600 x 210Outdoor unit 38HU09VSC 38HU12VSC 38HU18VSCSound power level** dB(A) 64 65 65Sound pressure level** dB(A) 54 56 57Air flow m3/h 1900 2100 2100Weight kg 26.0/29.0 28.5/31.5 38.0/40.5Dimension W x D x H mm 770 x 300 x 555 800 x 333 x 554 800 x 333 x 554System retail price £ 755 799 1,001* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

AccessoriesDescription Part Number Price, £Wired remote control for LC range - KJR-12- G2 7511630 73Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364

Page 9: Price List 2017 - CIAT

9

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

STELLAHigh-wall air conditioner

• Infra-red controller as standard (wired available).• Full Wi-Fi compatibility.• Self-clean operation and built-in Ioniser.• Louvre position memory.• Drain port on both sides for easy installation.• Refrigerant leakage detection display.

Inverter - R410AModel STELLA 9HV STELLA 12HV STELLA 18HV STELLA 24HVIndoor unit 42HV09VSC 42HV12VSC 42HV18VSC 42HV22VSCOutdoor unit 38HV09VSC 38HV12VSC 38HV18VSC 38HV24VSCCooling capacity Min./nom./max. kW 0.50/2.70/3.50 0.50/3.52/4.00 0.80/5.28/6.00 1.40/6.40/6.70Heating capacity* Min./nom./max. kW 0.60/2.90/4.00 0.60/3.90/4.50 1.00/5.50/6.30 1.50/7.00/7.30

@ -7°C kW 2.70 3.20 4.10 4.50@ -10°C kW 2.50 3.10 3.90 4.40@ -15°C kW 2.20 2.70 3.70 4.20

P design capacity cooling kW 2.70 4.00 5.00 6.00P design capacity heating Warmer/average kW 2.70/2.40 4.00/3.00 6.00/4.00 7.00/5.00Temperature range Cooling °C -15~46 -15~46 -15~46 -15~46

Heating °C -15~24 -15~24 -15~24 -15~24SEER W/W 7.4 7.0 7.1 7.1SCOP Warmer/average W/W 5.4/4.0 5.2/4.0 5.2/4.0 4.8/4.0Energy label SEER A++ A++ A++ A++

SCOP warmer/average A+++/A+ A+++/A+ A+++/A+ A++/A+Yearly energy consumption kWh 128/700/840 176/942/1015 260/1508/1505 315/1954/1820EER/COP W/W 3.38/3.73 3.12/3.51 3.25/3.20 3.11/3.30Rated current A 10.0 10.0 12.5 18.0Rated input kW 2.20 2.20 2.75 4.10Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 0.72 0.75 1.70 2.00Liquid side - gas side inch 1/4 - 3/8 1/4 - 3/8 1/4 - 1/2 3/8 - 5/8Standard piping length Min./max. piping length m 3/25 3/25 3/30 3/40

Max. height difference m 10 10 20 20Additional charge g/m 15 15 15 30

Indoor unit 42HV09VSC 42HV12VSC 42HV18VSC 42HV22VSCSound power level** dB(A) 53 54 57 63Sound pressure level** High/med./low/silence dB(A) 38/34/30/21 40/35/31/22 42/37/35/24 47/42/38/26Air flow High/med./low/silence m3/h 460/380/280/190 500/390/300/200 760/550/460/260 1150/890/770/420Weight kg 8.0 9.0 11.5 13.5Dimension W x D x H mm 730 x 192 x 291 812 x 192 x 300 973 x 218 x 319 1082 x 225 x 338Outdoor unit 38HV09VSC 38HV12VSC 38HV18VSC 38HV24VSCSound power level** dB(A) 63 64 65 69Sound pressure level** dB(A) 54 55 55 58Air flow m3/h 1900 2100 2100 2700Weight kg 26.5 28.5 38.0 44.0Dimension W x D x H mm 770 x 300 x 555 800 x 333 x 554 800 x 333 x 554 845 x 363 x 702System retail price £ 468 524 730 944* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

AccessoriesDescription Part Number Price, £Wired remote control for high-wall units - KJR-12- G1 7511629 68Wi-Fi USB for hung wall range - WIFI USB 7511628 17

Page 10: Price List 2017 - CIAT

10

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

SALSACassette air conditioner

• Infra-red controller as standard (wired available).• Louvre position memory.• Drain pump up to 750 mm.• Full Wi-Fi compatibility.• 360° air distribution.• Fresh air intake and fan compatible.

Inverter - R410AModel SALSA 9HV SALSA 12HV SALSA 18HV SALSA 24HV SALSA 36HVIndoor unit 42HK09VSC 42HK12VSC 42KH18VSC 42HK24VSC 42HK36VSCIndoor unit panel 40CAS-C6 40CAS-C6 40CAS-C6 40CAS-L9 40CAS-L9Outdoor unit 38HU09VSC 38HU12VSC 38HU18VSC 38HU24VSC 38HU36VSCCooling capacity Min./nom./max. kW 0.90/2.64/3.70 1.40/3.52/3.90 2.00/5.00/5.50 2.50/7.03/8.00 4.50/10.20/11.00Heating capacity* Min./nom./max. kW 0.80/3.00/3.80 1.20/4.00/4.20 2.00/5.50/6.00 2.50/7.03/8.50 3.70/11.30 13.70

@ -7°C kW 3.00 2.70 3.90 5.40 9.70@ -10°C kW 3.00 2.70 3.90 5.00 8.30@ -15°C kW 2.00 2.40 2.20 3.70 8.20

P design capacity cooling kW 2.64 3.52 5.00 7.03 10.20P design capacity heating Warmer/average kW 2.40/2.60 2.94/3.50 3.90/4.90 5.54/7.80 9.30/10.30Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24 -15~24 -15~24SEER W/W 6.2 6.2 6.0 6.1 6.0SCOP Warmer/average W/W 4.0/5.1 4.1/5.1 4.0/5.1 4.0/4.8 4.0/5.0Energy label SEER A++ A++ A+ A++ A+

SCOP warmer/average A++/A+++ A+/A+++ A+/A+++ A+/A++ A+/A++Yearly energy consumption kWh 149/837/714 199/1002/960 293/1365/1345 403/1937/2277 588/3244/2894EER/COP W/W 3.5/3.7 3.1/3.6 2.8/3.1 3.0/3.2 2.7/3.4Rated current A 10 10 11 16 23Rated input kW 2.30 2.30 2.53 3.68 4.80Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 0.72 1.05 1.70 2.05 3.65Liquid side - gas side inch 1/4 - 3/8 1/4 - 3/8 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/25 3/25 3/30 3/40 3/50

Max. height difference m 10 10 20 20 25Additional charge g/m 15 15 15 30 30

Indoor unit 42HK09VSC 42HK12VSC 42HK18VSC 42HK24VSC 42HK36VSCSound power level** dB(A) 58 59 60 61 65Sound pressure level** High/med./low dB(A) 42/39/36 42/39/36 45/42/36 49/46/43 53/51/48Air flow High/med./low m3/h 560/430/390 560/430/391 650/530/370 1350/1200/1070 1800/1600/1400Weight Body kg 15.0/18.0 16.5/19.0 16.5/19.0 24.5/30.0 27.5/31.5

Panel kg 2.5/4.5 2.5/4.5 2.5/4.5 5.0/8.0 5.0/8.0Dimension Body W x D x H mm 570 x 570 x 260 570 x 570 x 260 570 x 570 x 260 840 x 840 x 245 840 x 840 x 245

Panel W x D x H mm 647 x 647 x 50 647 x 647 x 50 647 x 647 x 50 950 x 950 x 55 950 x 950 x 55Outdoor unit 38HU09VSC 38HU12VSC 38HU18VSC 38HU24VSC 38HU36VSCSound power level** dB(A) 64 65 65 69 70Sound pressure level** dB(A) 54 56 57 61 64Air flow m3/h 1900 2100 2100 2700 4150Weight kg 26.0/29.0 28.5/31.5 38.0/40.5 50.0/54.5 70.5/76.1Dimension W x D x H mm 770 x 300 x 555 800 x 333 x 554 800 x 333 x 554 845 x 363 x 702 946 x 410 x 810System retail price £ 797 831 1,108 1,472 2,164* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

AccessoriesDescription Part Number Price, £Wired remote control for LC range - KJR-12- G2 7511630 73Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364

Page 11: Price List 2017 - CIAT

11

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

SALSACassette air conditioner

Inverter - R410AModel SALSA 36HVT SALSA 48HV SALSA 48HVT SALSA 60HVIndoor unit 42HK36VSC 42HK48VSC 42HK48VSC 42HK60VSCIndoor unit panel 40CAS-L9 40CAS-L9 40CAS-L9 40CAS-L9Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTCCooling capacity Min./nom./max. kW 3.80/10.20/11.50 4.80/13.40/14.00 4.80/13.40/14.00 5.00/15.10/16.00Heating capacity* Min./nom./max. kW 2.90/11.30/13.80 5.40/15.50/16.00 5.40/15.50/16.00 3.90/18.00/18.20

@ -7°C kW 9.60 10.40 10.50 12.20@ -10°C kW 8.20 9.90 10.00 11.90@ -15°C kW 8.10 8.40 8.50 9.80

P design capacity cooling kW 10.20 13.40 13.40 15.10P design capacity heating Warmer/average kW 9.60/10.20 10.70/11.80 11.00/11.80 11.20/12.10Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24 -15~24SEER W/W 5.9 5.5 5.6 5.7SCOP Warmer/average W/W 4.0/5.0 4.0/5.0 4.0/5.1 4.0/5.2Energy label SEER A+ A A+ A+

SCOP warmer/average A+/A++ A+/A++ A+/A+++ A+/A+++Yearly energy consumption kWh 610/3360/2885 852/3756/3323 834/3847/3231 929/3916/3225EER/COP W/W 2.6/3.4 2.4/2.9 2.5/3.0 2.4/3.1Rated current A 12 26.5 13 14Rated input kW 4.80 6.10 6.10 7.50Power supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50Refrigerant amount R410A kg 3.65 4.00 4.00 4.30Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/50 3/50 3/50 3/50

Max. height difference m 25 25 25 25Additional charge g/m 30 30 30 30

Indoor unit 42HK36VSC 42HK48VSC 42HK48VSC 42HK60VTCSound power level** dB(A) 65 67 67 70Sound pressure level** High/med./low dB(A) 53/51/48 51/49/47 51/49/47 54/52/49Air flow High/med./low m3/h 1800/1600/1400 1900/1600/1330 1900/1600/1330 2000/1780/1580Weight Body kg 27.5/31.5 28/32,1 28/32,1 31.0/34.0

Panel kg 5.0/8.0 5.0/8.0 5.0/8.0 5.0/8.0Dimension Body W x D x H mm 840 x 840 x 245 840 x 840 x 245 840 x 840 x 245 840 x 840 x 245

Panel W x D x H mm 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTCSound power level** dB(A) 70 75 75 77Sound pressure level** dB(A) 64 64 64 64Air flow m3/h 4150 6800 6800 7000Weight kg 85.3/91.0 95.1/108.4 108.1/121.2 112.8/126.0Dimension W x D x H mm 946 x 410 x 810 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333System retail price £ 2,332 2,611 2,641 2,764* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

Page 12: Price List 2017 - CIAT

12

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

TWISTDucted air conditioner

Inverter - R410AModel TWIST 12HV TWIST 18HV TWIST 24HV TWIST 36HVIndoor unit 42HY12VSC 42HY18VSC 42HY24VSC 42HY36VSCOutdoor unit 38HU12VSC 38HU18VSC 38HU24VSC 38HU36VSCCooling capacity Min./nom./max. kW 1.40/3.52/3.90 2.00/5.00/5.50 2.50/7.03/7.70 3.70/10.20/11.00Heating capacity* Min./nom./max. kW 1.20/3.80/4.20 2.00/5.40/6.00 2.40/7.40/8.70 3.00/12.70/14.00

@ -7°C kW 2.50 4.00 5.30 10.30@ -10°C kW 2.20 3.60 4.70 9.60@ -15°C kW 2.00 2.50 3.50 8.30

P design capacity cooling kW 3.52 5.00 7.03 10.20P design capacity heating Warmer/average kW 2.83/3.44 4.20/5.34 5.20/7.50 10.30/10.60Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24 -15~24SEER W/W 6.1 6.3 6.1 6.2SCOP Warmer/average W/W 4.0/5.1 4.0/5.1 4.0/5.1 4.0/5.1Energy label SEER A++ A++ A++ A++

SCOP warmer/average A+/A+++ A+/A+++ A+/A+++ A+/A+++Yearly energy consumption kWh 202/985/941 277/1468/1465 401/1820/2058 574/3598/2888EER/COP W/W 2.8/3.2 2.8/3.6 3.1/3.4 2.6/3.7Rated current A 10 11 16 23Rated input kW 2.30 2.53 3.68 4.30Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 1.05 1.70 2.05 3.65Liquid side - gas side inch 1/4 - 3/8 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/25 3/30 3/40 3/50

Max. height difference m 10 20 20 25Additional charge g/m 15 15 30 30

Indoor unit 42HY12VSC 42HY18VSC 42HY24VSC 42HY36VSCSound power level** dB(A) 60 60 61 65Sound pressure level** High/med./low dB(A) 42/38/35 42/40/38 43/40/38 47/42/42Air flow High/med./low m3/h 540/500/370 790/660/490 1120/900/420 1900/1550/1200Weight kg 18.5/23.0 23.0/29.0 30.2/37.3 40.5/48.5Dimension W x D x H mm 915 x 655 x 290 880 x 674 x 210 1305 x 805 x 305 1360 x 774 x 249Outdoor unit 38HU12VSC 38HU18VSC 38HU24VSC 38HU36VSCSound power level** dB(A) 65 65 69 70Sound pressure level** dB(A) 56 57 61 64Air flow m3/h 2100 2100 2700 4150Weight kg 28.5/31.5 38.0/40.5 50.0/54.5 70.5/76.1Dimension W x D x H mm 800 x 333 x 554 800 x 333 x 554 845 x 363 x 702 946 x 410 x 810System retail price £ 836 1,161 1,511 2,330* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

AccessoriesDescription Part Number Price, £Wired remote control for LC range - KJR-12- G2 7511630 73Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364

• Infra-red controller as standard (wired available).• Full Wi-Fi compatibility.• Slim and compact design.• High static pressure up to 160 Pa.• Variable static pressure setting.• Anti-cold draught function.

Page 13: Price List 2017 - CIAT

13

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

TWISTDucted air conditioner

Inverter - R410AModel TWIST 36HVT TWIST 48HV TWIST 48HVT TWIST 60HVIndoor unit 42HY36VSC 42HY48VSC 42HY48VSC 42HY60VSCOutdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTCCooling capacity Min./nom./max. kW 3.60/10.20/11.00 5.10/13.70/14.40 4.90/13.70/14.20 5.20/15.40/16.00Heating capacity* Min./nom./max. kW 2.70/12.70/13.50 4.40/15.40/16.40 4.70/15.40/16.90 4.80/17.60/18.80

@ -7°C kW 9.90 10.80 11.60 12.60@ -10°C kW 9.10 10.30 10.70 11.80@ -15°C kW 8.10 8.90 9.10 10.20

P design capacity cooling kW 10.20 13.70 13.70 15.40P design capacity heating Warmer/average kW 10.00/10.30 10.30/11.60 11.50/12.40 12.00/12.20Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46

Heating °C -15~24 -15~24 -15~24 -15~24SEER W/W 6.2 5.8 5.9 5.5SCOP Warmer/average W/W 4.0/5.0 4.0/4.9 4.0/5.4 4.0/5.1Energy label SEER A++ A+ A+ A

SCOP warmer/average A+/A++ A+/A++ A+/A+++ A+/A+++Yearly energy consumption kWh 577/3481/2912 826/3597/3337 813/4030/3206 963/4196/3328EER/COP W/W 2.6/3.7 2.7/3.5 2.6/3.7 2.3/3.4Rated current A 12 26.5 13 14Rated input kW 4.80 6.10 6.10 7.50Power supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50Refrigerant amount R410A kg 3.65 4.00 4.00 4.30Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8Standard piping length Min./max. piping length m 3/50 3/50 3/50 3/50

Max. height difference m 25 25 25 25Additional charge g/m 30 30 30 30

Indoor unit 42HY36VSC 42HY48VSC 42HY48VSC 42HY60VTCSound power level** dB(A) 65 71 71 76Sound pressure level** High/med./low dB(A) 47/45/43 53/51/49 53/51/49 58/56/54Air flow High/med./low m3/h 1900/1550/1200 2400/2050/1750 2400/2050/1750 2500/2100/1800Weight kg 40.5/48.5 46.0/55.0 46.0/55.0 46.0/55.0Dimension W x D x H mm 1360 x 774 x 249 1200 x 874 x 300 1200 x 874 x 300 1200 x 874 x 300Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTCSound power level** dB(A) 70 75 75 77Sound pressure level** dB(A) 64 64 64 64Air flow m3/h 4150 6800 6800 7000Weight kg 85.3/91.0 95.1/108.4 108.1/121.2 112.8/126Dimension W x D x H mm 1090 x 500 x 875 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333System retail price £ 2,497 2,706 2,735 2,813* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode

Page 14: Price List 2017 - CIAT

14

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

Multi-split systemOutdoor units

Inverter - R410ASystem 2-way multi 3-way multiIndoor unit 42HV09VSC x 2 42HC09VSC x 2 42HV09VSC x 3 42HC09VSC x 3Indoor unit type High-wall Console High-wall ConsoleOutdoor unit 38HM18VSC 38HM18VSC 38HM27VSC 38HM27VSCCooling capacity Nom. kW 5.30 5.20 7.92 7.92Heating capacity Nom. kW 5.60 5.90 8.20 8.20Temperature range Cooling/heating °C -10~46/-15~24 -10~46/-15~24 -10~46/-15~24 -10~46/-15~24SEER/SCOP W/W 6.62/3.91 5.65/3.80 6.10/4.00 6.10/4.00Energy label SEER A++ A+ A++ A++

SCOP Average A A A+ A+Yearly energy consumption kWh 280/1780 322/1916 454/2030 454/1995Rated current A 12 12 16 16Rated input kW 2.30 2.30 3.30 3.30Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 1.90 1.90 2.10 2.10Liquid side - gas side inch 1/4 - 3/8 1/4 - 3/8 1/4 - 3/8 1/4 - 3/8Max. piping length Total/indoor unit m 40/25 40/25 60/30 60/30Max. height difference Indoor to outdoor m 15 15 15 15Max. height difference Between 2 indoors m 10 10 10 10Sound power/pressure level* dB(A) 66/59.5 66/59.5 68/61 68/61Air flow m3/h 2700 2700 2700 2700Weight kg 49 49 53 53Dimension W x D x H mm 845 x 363 x 702 845 x 363 x 702 845 x 363 x 765 845 x 363 x 765Price Indoor unit £ 2 x 129 2 x 326 3 x 129 3 x 326

Outdoor unit £ 845 845 996 996

System 4-way multi 5-way multiIndoor unit 42HV09VSC x 4 42HC09VSC x 4 42HV09VSC x 5 42HC09VSC x 5Indoor unit type High-wall Console High-wall ConsoleOutdoor unit 38HM36VSC 38HM36VSC 38HM42VSC 38HM42VSCCooling capacity Nom. kW 10.60 10.60 12.30 12.30Heating capacity Nom. kW 11.20 11.20 12.50 12.50Temperature range Cooling/heating °C -10~46/-15~24 -10~46/-15~24 -10~46/-15~24 -10~46/-15~24SEER/SCOP W/W 5.90/3.80 5.80/3.80 5.60/3.80 5.80/3.80Energy label SEER A++ A++ A+ A+

SCOP Average A A A AYearly energy consumption kWh 626/3426 640/3353 769/3537 742/3463Rated current A 21.5 21.5 22 22Rated input kW 4.60 4.60 4.70 4.70Power supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50Refrigerant amount R410A kg 3.00 3.00 3.60 3.60Liquid side - gas side inch 3 x 1/4 - 3/8

1 x 1/4 - 1/23 x 1/4 - 3/8 1 x 1/4 - 1/2

4 x 1/4 - 3/8 1 x 1/4 - 1/2

4 x 1/4 - 3/8 1 x 1/4 - 1/2

Max. piping length Total/indoor unit m 80/35 80/35 80/35 80/35Max. height difference Indoor to outdoor m 15 15 15 15Max. height difference Between 2 indoors m 10 10 10 10Sound power/pressure level* dB(A) 68/63 68/63 68/63 68/63Air flow m3/h 4000 4000 4000 4000Weight kg 70 70 76 76Dimension W x D x H mm 946 x 410 x 810 946 x 410 x 810 946 x 410 x 810 946 x 410 x 810Price Indoor unit £ 4 x 129 4 x 326 5 x 129 5 x 326

Outdoor unit £ 1,579 1,579 1,584 1,584* Sound data in cooling mode

• Suitable for 2 to 5 indoor units off a single outdoor.• Infra-red remote control as standard.• Individual control for each indoor unit.• Mixed capacities available on outdoor units.• Up to 130% connected capacity available.• Automatic correction of wiring crossover.

Page 15: Price List 2017 - CIAT

15

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

Multi-split systemIndoor units

Indoor unit Model number Size Approx. kW Price, £Mambo console

42HC09VSC 9k 2.6 £326

42HC12VSC 12k 3.5 £360

42HC18VSC 18k 4.4 £372

Stella high-wall42HV09VSC 9k 2.7 £129

42HV12VSC 12k 3.5 £155

42HV18VSC 18k 5.3 £204

42HV22VSC 24k 6.4 £250

Salsa cassette42HK09VSC 9k 2.6 £309

42HK12VSC 12k 3.5 £333

42HK18VSC 18k 5.0 £420

42HK24VSC 24k 7.0 £437

Twist ducted42HY12VSC 12k 3.5 £394

42HY18VSC 18k 5.0 £530

42HY24VSC 24k 7.0 £571

Note: kW capacity varies depending on total connected capacity.

The multi-split system allows the ability to utilise different styles and capacity of units to be connected to a single outdoor unit to maximise flexibility.

Page 16: Price List 2017 - CIAT

16

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

Multi-split system

Possible system combinationsMULTI-SPLIT 2 INDOOR UNITS1 x indoor unit 2 x indoor unit

9 9+912 9+12

MULTI-SPLIT 3 INDOOR UNITS1 x indoor unit 2 x indoor unit 3 x indoor unit

9 9+9 12+12 9+9+9 9+12+1212 9+12 12+18 9+9+12 12+12+1218 9+18 18+18 9+9+18

MULTI-SPLIT 4 INDOOR UNITS1 x indoor unit 2 x indoor unit 3 x indoor unit 4 x indoor unit

9 9+9 12+12 9+9+9 9+12+12 12+12+12 9+9+9+9 9+9+12+1812 9+12 12+18 9+9+12 9+12+18 12+12+18 9+9+9+12 9+12+12+1218 9+18 12+24 9+9+18 9+12+24 12+12+24 9+9+9+18 12+12+12+1224 9+24 18+18 9+9+24 9+18+18 12+18+18 9+9+12+12

MULTI-SPLIT 5 INDOOR UNITS1 x indoor unit 2 x indoor unit 3 x indoor unit 4 x indoor unit 5 x indoor unit

9 9+9 12+12 9+9+9 9+12+12 12+12+12 9+9+9+9 9+9+12+12 9+12+12+18 9+9+9+9+912 9+12 12+18 9+9+12 9+12+18 12+12+18 9+9+9+12 9+9+12+18 12+12+12+12 9+9+9+9+1218 9+18 12+24 9+9+18 9+12+24 12+12+24 9+9+9+18 9+9+12+24 12+12+12+18 9+9+9+9+1824 9+24 18+18 9+9+24 9+18+18 12+18+18 9+9+9+24 9+12+12+12 9+9+9+12+12

Note:1. The capacity is tested with standard 9K indoor unit as below: 18K condensing unit + 2 x 9K indoor units 27K condensing unit + 3 x 9K indoor units 36K condensing unit + 4 x 9K indoor units 42K condensing unit + 5 x 9K indoor units2. 18K indoor units should apply 1/2” gas pipe with one additional adapter 3/8’’-1/2” required in condensing unit.3. 24K indoor units should apply 3/8” liquid pipe with one additional adapter 1/4’’-3/8” required in indoor units, and apply 5/8” gas pipe with one

additional adapter 1/2’’-5/8” in condensing unit.

Page 17: Price List 2017 - CIAT

17

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

EREBAReversible heat pump

• Easy installation with 12 pre-set climate curves.• Full inverter controlling the twin rotary compressor.• New controller offers optimised control.• Integrated Hydraulic module A-class variable speed pump.• Water outlet temperature up to 60°C.• Defrost protection <-20°C.• Units supplied with flexible connections and anti-vibration mounts as standard.EREBA 4H 6H 8H 12H 15H 12HT 15HT 17HT 21HTUnderfloor heating 30/35°C*Heating to 7/6°C kW 4.10 5.80 7.20 11.90 14.46 12.00 15.00 16.90 20.70COP/SCOP 4.06/3.73 4.20/3.60 3.91/3.03 3.91/3.19 4.09/3.61 4.30/3.78 4.20/3.68 4.23/3.68 4.15/3.56Energy class A+ A+ A A+ A+ A+ A+ A+ A+Fan coil 40/45°C*Heating to 7/6°C kW 3.90 5.80 7.40 12.95 13.96 11.20 14.50 15.80 19.50COP 3.20 3.01 3.16 3.01 3.23 3.35 3.30 3.44 3.32Radiators 47/55°C*Heating to 7/6°C kW 4.10 5.40 6.70 11.50 11.66 11.43 12.17 15.00 20.80COP/SCOP 2.72/3.53 2.58/3.37 2.30/2.84 2.48/2.95 2.82/3.25 3.12/3.47 2.98/3.33 2.68/3.03 2.50/2.85Energy class A++ A++ A+ A+ A++ A++ A++ A+ A+Cooling mode 23/18°C**Cooling to 35°C kW 4.93 7.04 7.84 13.54 16.04 13.50 16.00 21.40 26.40EER/ESEER 4.20/4.36 3.70/4.51 3.99/4.15 3.66/4.22 3.85/4.31 4.15/4.40 3.81/4.31 4.00/4.40 4.00/4.20Sound power* dB(A) 62 62 64 67 68 68 68 71 74Power supply V-ph-Hz 230-1-50 400-3- 50Part Number 7422274 7422275 7422276 7422277 7422278 7422279 7422280 7469145 7469147Price £ 3,742 4,048 4,316 6,245 6,799 6,608 7,086 7,908 9,206* Following conditions NFPAC. Certified data NFPAC under No. NF414-1252 (except three-phase models).** Following conditions EUROVENT LCP/A/CHF water 23/18°C, air 35°C.

AccessoriesDescription Sizes 4H-15H/HT Price, £ Sizes 17H/HT–21HT Price, £Screen filter valve kit 7166295 73 Included -Charging kit/1-1/4 filling kit 7013876 82 7013877 9550 l 4-nozzle mixing tank 7328746 335 - -100 l 8-nozzle mixing tank 7328744 421 7328744 421200 l 8-nozzle mixing tank 7328747 730 7328747 730DUO hydraulic module 3911008 1,397 3911008 1,3975 kW single-phase loop heater (only available for sizes 4H-15H) 7148641 761 - -9 kW three-phase loop heater (only available for sizes 12HT-21HT) 7148642 924 7148642 9249 kW back-up heater for mounting in 200 l tank - - 7221389 383300 l DHW tank 7385910 1,195 7385910 1,1953-way valve for DHW 300 l 7422270 299 7422270 299DHW sensor & 3-way valve kit (required with 300 l DHW tank) - - 7411357 445Underfloor heating/cooling system limiter thermostat 7422271 68 7274278 68Sensor for 4 units operating in parallel – modular configuration - - 7484985 34Outdoor sensor - - 7484983 30Pool heating kit (sensor + 3-way valves) - - 7111122 445ITEX exchanger pool+ Ti 24 - - 7268481 824

3-Year Warranty Available

Page 18: Price List 2017 - CIAT

18

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

EREBA performance tablesCooling capacities

Outdoor air temperature, °CEREBA Chilled

water temp.,°C

5 15 25 35 45CC kW PI kW CC kW PI kW CC kW PI kW CC kW PI kW CC kW PI kW

Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max.4H

5

1.3 1.2 1.3 0.2 0.1 0.2 1.2 1.1 1.2 0.2 0.1 0.2 3.5 0.9 3.5 1.0 0.2 1.0 3.0 0.8 3.1 1.1 0.2 1.2 2.7 0.7 2.8 1.3 0.2 1.46H 1.1 1.0 1.1 0.1 0.1 0.1 1.0 0.9 1.0 0.1 0.1 0.1 5.2 0.8 5.2 1.4 0.1 1.4 4.3 0.7 4.9 1.5 0.1 2.0 3.8 0.5 4.4 1.8 0.1 2.38H 6.2 0.6 7.3 0.7 0.1 0.9 5.6 0.5 6.7 1.0 0.1 1.2 5.1 0.5 6.0 1.3 0.1 1.6 4.5 0.4 5.3 1.6 0.1 1.9 3.9 0.4 4.6 1.9 0.1 2.412H 14.7 4.6 17.0 2.5 0.5 3.5 11.8 4.3 13.4 2.4 0.7 3.0 10.8 3.9 12.2 2.9 0.9 3.6 9.6 3.5 10.9 3.5 1.1 4.2 8.4 3.0 9.5 4.1 1.3 5.012HT 13.8 4.5 19.7 2.3 0.5 4.5 11.4 4.1 15.9 2.2 0.7 3.5 10.4 3.7 14.5 2.8 0.9 4.2 9.6 3.3 13.0 3.4 1.0 4.9 8.9 2.8 9.6 3.7 1.2 4.515H 19.1 4.5 20.0 3.7 0.5 4.2 15.3 4.2 15.7 3.3 0.7 3.3 14.0 3.8 14.3 3.9 0.9 4.0 12.5 3.4 12.9 4.5 1.0 4.8 9.2 2.9 9.5 4.2 1.2 4.415HT 19.1 4.5 20.0 3.7 0.5 4.2 15.3 4.2 15.7 3.3 0.7 3.3 14.0 3.8 14.3 3.9 0.9 4.0 12.5 3.4 12.9 4.5 1.0 4.8 9.2 2.9 9.5 4.2 1.2 4.417HT - - - - - - 15.4 9.9 15.4 3.4 1.7 3.4 14.5 9.0 14.5 3.8 2.0 3.8 14.3 3.0 14.8 4.7 1.3 5.0 12.3 4.0 12.3 5.2 2.7 5.221HT - - - - - - 20.5 12.8 24.5 4.4 3.9 6.3 19.9 13.8 23.8 4.9 3.2 6.9 18.1 8.3 22.3 5.8 2.5 8.3 15.2 6.5 16.4 6.4 2.8 7.14H

7

1.4 1.3 1.4 0.2 0.1 0.2 1.3 1.2 1.3 0.2 0.1 0.2 3.8 1.0 3.8 1.0 0.2 1.0 3.3 0.9 3.5 1.1 0.2 1.2 2.9 0.8 3.1 1.3 0.2 1.46H 1.3 1.2 1.3 0.1 0.1 0.1 1.1 1.0 1.1 0.1 0.1 0.1 5.6 0.9 5.6 1.4 0.1 1.4 4.7 0.7 5.3 1.6 0.1 2.0 4.2 0.6 4.7 1.9 0.1 2.38H 6.9 0.7 8.0 0.8 0.1 0.9 6.3 0.6 7.2 1.0 0.1 1.2 5.6 0.6 6.5 1.3 0.1 1.6 5.0 0.5 5.8 1.7 0.1 2.0 4.4 0.4 5.1 2.0 0.2 2.412H 13.6 5.1 15.6 1.8 0.5 2.3 12.6 4.7 14.4 2.4 0.7 3.1 11.5 4.3 13.1 3.0 0.9 3.7 10.2 3.8 11.7 3.5 1.1 4.4 8.7 3.3 9.9 4.1 1.3 5.012HT 12.8 4.9 17.8 1.6 0.5 2.6 12.1 4.5 16.9 2.1 0.6 3.5 11.1 4.1 15.4 2.8 0.8 4.2 10.2 3.7 13.7 3.4 1.0 4.9 9.3 3.1 10.2 3.6 1.2 4.615H 17.4 5.0 18.1 2.3 0.5 2.6 16.0 4.6 16.7 3.1 0.6 3.4 14.6 4.2 15.2 3.8 0.8 4.1 13.0 3.8 13.6 4.5 1.0 4.8 9.8 3.2 10.1 4.3 1.2 4.415HT 17.4 5.0 18.1 2.3 0.5 2.6 16.0 4.6 16.7 3.1 0.6 3.4 14.6 4.2 15.2 3.8 0.8 4.1 13.0 3.8 13.6 4.5 1.0 4.8 9.8 3.2 10.1 4.3 1.2 4.417HT - - - - - - 16.3 10.5 16.3 3.5 1.7 3.5 15.6 9.6 15.6 3.8 2.0 3.8 15.2 3.2 15.8 4.8 1.3 5.1 13.1 4.2 13.1 5.3 2.8 5.321HT - - - - - - 21.6 13.5 26.3 4.6 4.0 6.4 21.1 14.7 25.2 5.0 3.3 7.1 19.1 8.9 23.6 6.0 2.5 8.5 16.1 6.9 17.4 6.6 2.8 7.24H

10

- - - - - - 1.5 1.3 1.5 0.2 0.1 0.2 4.3 1.2 4.3 1.0 0.2 1.0 3.7 1.0 3.9 1.2 0.2 1.3 3.3 0.9 3.4 1.3 0.2 1.46H 1.4 1.3 1.4 0.1 0.1 0.1 1.3 1.2 1.3 0.1 0.1 0.1 6.3 1.0 6.3 1.5 0.1 1.5 5.3 0.9 5.9 1.7 0.1 2.1 4.7 0.7 5.2 2.0 0.1 2.38H 7.9 0.9 8.9 0.8 0.1 1.0 7.2 0.8 8.1 1.1 0.1 1.3 6.5 0.7 7.3 1.4 0.1 1.7 5.8 0.6 6.5 1.8 0.1 2.1 5.0 0.6 5.7 2.1 0.2 2.512H 12.1 5.9 13.5 1.2 0.5 1.4 13.7 5.4 15.9 2.4 0.7 3.4 12.5 4.9 14.5 3.0 0.9 4.0 11.1 4.4 12.9 3.6 1.1 4.6 9.1 3.7 10.6 4.0 1.4 5.012HT 11.4 5.6 15.0 1.0 0.4 1.5 13.3 5.2 18.4 2.1 0.6 3.7 12.2 4.7 16.7 2.7 0.8 4.3 11.1 4.2 14.7 3.4 1.0 4.9 10.0 3.6 11.2 3.5 1.2 4.715H 14.7 5.7 15.3 1.4 0.4 1.4 17.0 5.3 18.2 3.0 0.6 3.5 15.5 4.8 16.6 3.7 0.8 4.2 13.8 4.3 14.6 4.4 1.0 4.8 10.7 3.7 11.0 4.4 1.2 4.515HT 14.7 5.7 15.3 1.4 0.4 1.4 17.0 5.3 18.7 3.0 0.6 3.5 15.5 4.8 16.6 3.7 0.8 4.2 13.8 4.3 14.6 4.4 1.0 4.8 10.7 3.7 11.0 4.4 1.2 4.517HT - - - - - - 17.8 6.2 17.8 3.6 0.7 3.6 17.1 5.2 17.1 3.9 1.2 3.9 16.6 3.6 17.3 5.0 1.3 5.3 14.3 4.7 14.4 5.5 2.8 5.521HT - - - - - - 23.3 8.1 28.7 4.8 1.7 6.5 22.9 8.4 27.3 5.2 1.9 7.4 20.9 9.7 25.6 6.4 2.7 8.8 17.6 7.6 19.0 6.8 2.9 7.54H

15

- - - - - - - - - - - - 5.1 1.4 5.1 1.0 0.2 1.0 4.5 1.3 4.7 1.2 0.2 1.3 3.9 1.1 4.0 1.4 0.2 1.46H 1.6 1.6 1.6 0.1 0.1 0.1 1.6 1.4 1.6 0.1 0.1 0.1 7.4 1.2 7.4 1.6 0.1 1.6 6.4 1.1 6.9 1.9 0.1 2.2 5.6 0.9 6.0 2.2 0.2 2.48H 9.7 1.1 10.5 0.9 0.1 1.1 8.8 1.0 9.6 1.2 0.1 1.3 8.0 0.9 8.7 1.5 0.1 1.7 7.0 0.8 7.7 1.9 0.2 2.2 6.2 0.7 6.8 2.3 0.2 2.612H 7.1 7.1 7.1 0.5 0.5 0.5 15.5 6.6 18.4 2.4 0.6 3.7 14.1 6.0 16.8 3.0 0.9 4.3 12.6 5.3 14.9 3.7 1.2 4.9 9.9 4.5 11.7 3.8 1.4 5.012HT 6.8 6.8 6.8 0.4 0.4 0.4 15.1 6.3 20.9 2.0 0.5 3.8 14.1 5.7 19.0 2.7 0.8 4.4 12.6 5.1 16.5 3.3 1.0 5.0 11.1 4.3 12.8 3.4 1.2 4.815H 6.9 6.9 6.9 0.4 0.4 0.4 18.8 6.4 20.7 2.8 0.5 3.7 17.1 5.8 18.8 3.5 0.8 4.3 15.2 5.2 16.3 4.3 1.0 4.8 12.2 4.4 12.6 4.5 1.2 4.715HT 6.9 6.9 6.9 0.4 0.4 0.4 18.8 6.4 20.7 2.8 0.5 3.7 17.1 5.8 18.8 3.5 0.8 4.3 15.2 5.2 16.3 4.3 1.0 4.8 12.2 4.4 12.6 4.5 1.2 4.717HT - - - - - - 20.4 7.0 20.4 3.8 0.7 3.8 19.8 6.1 19.8 4.0 1.1 4.0 19.2 4.2 19.9 5.2 1.2 5.6 16.7 5.4 16.7 5.8 2.9 5.821HT - - - - - - 27.3 9.5 33.3 4.8 1.6 6.8 26.2 9.8 31.0 5.4 1.9 7.9 23.9 11.2 29.1 6.8 2.7 9.4 20.2 8.8 21.8 7.1 3.0 7.94H

18

- - - - - - - - - - - - 5.6 1.6 5.6 1.0 0.2 1.0 4.9 1.4 5.2 1.2 0.2 1.4 4.3 1.2 4.4 1.4 0.2 1.46H 1.8 1.8 1.8 0.1 0.1 0.1 1.7 1.6 1.7 0.1 0.1 0.1 8.1 1.4 8.1 1.6 0.1 1.6 7.0 1.2 7.5 1.9 0.2 2.2 6.2 1.0 6.5 2.3 0.2 2.48H 10.7 1.3 11.5 1.0 0.1 1.1 9.8 1.2 10.5 1.2 0.1 1.3 8.9 1.1 9.5 1.6 0.1 1.8 7.8 1.0 8.4 2.0 0.2 2.2 0.9 0.9 0.9 0.2 0.2 0.212H 7.9 7.9 7.9 0.5 0.5 0.5 16.6 7.3 19.9 2.4 0.6 3.9 15.1 6.6 18.1 3.1 0.9 4.5 13.5 5.9 16.1 3.7 1.2 5.0 10.3 5.0 12.4 3.7 1.5 5.012HT 7.5 7.5 7.5 0.4 0.4 0.4 16.3 6.9 22.4 1.9 0.5 3.9 15.2 6.3 20.4 2.6 0.7 4.5 13.5 5.6 17.5 3.3 1.0 5.0 11.8 4.8 13.7 3.3 1.2 4.915H 7.7 7.7 7.7 0.4 0.4 0.4 19.8 7.1 22.2 2.7 0.5 3.8 18.0 6.4 20.2 3.4 0.7 4.4 16.0 5.7 17.3 4.2 1.0 4.8 13.0 4.9 13.6 4.6 1.2 4.715HT 7.7 7.7 7.7 0.4 0.4 0.4 19.8 7.1 22.2 2.7 0.5 3.8 18.0 6.4 20.2 3.4 0.7 4.4 16.0 5.7 17.3 4.2 1.0 4.8 13.0 4.9 13.6 4.6 1.2 4.717HT - - - - - - 22.0 7.1 22.0 4.0 0.8 4.0 21.5 7.0 21.9 4.1 0.9 4.2 21.4 4.6 21.6 5.4 1.2 5.6 18.5 5.9 18.5 5.9 2.9 5.921HT - - - - - - 29.8 9.9 36.3 4.9 1.8 7.0 28.3 10.8 33.3 5.6 1.8 8.2 26.4 12.2 31.3 6.6 2.8 9.8 21.9 9.6 23.6 7.3 3.0 8.1PI Power input, kW (power input values include the compressor, fans and control)CC Cooling capacity, kW

Evaporator entering/leaving water temperature difference: 5 KEvaporator fluid: chilled waterFouling factor: 0 m2 K/W

Performances in accordance with EN14511-3:2011.

Page 19: Price List 2017 - CIAT

19

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

EREBA performance tablesHeating capacities

Leaving hot water temperature, °CHeating floor Comfort unit Radiator

EREBA Outdoor air temp., °C

35 45 55 60HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW

Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max.4H

-20

1.2 0.5 1.2 1.1 0.3 1.1 1.2 0.4 1.2 1.1 0.2 1.1 0.4 0.4 0.4 0.2 0.2 0.2 - - - - - -6H 3.0 0.5 3.1 1.5 0.2 1.6 1.4 0.4 1.4 0.8 0.2 0.8 0.4 0.4 0.4 0.3 0.3 0.3 - - - - - -8H 1.8 0.6 1.8 0.7 0.2 0.7 1.3 0.6 1.3 0.6 0.3 0.6 0.5 0.5 0.5 0.3 0.3 0.3 - - - - - -12H 3.2 1.5 3.2 1.5 0.7 1.5 3.0 1.2 3.0 1.5 0.6 1.5 1.1 1.1 1.1 0.7 0.7 0.7 - - - - - -12HT 4.0 1.3 4.0 2.1 0.7 2.1 3.0 1.4 3.0 1.7 0.8 1.7 1.3 1.3 1.3 0.8 0.8 0.8 - - - - - -15H 4.5 1.3 4.5 2.5 0.7 2.5 3.0 1.3 3.0 1.8 0.7 1.8 1.3 1.3 1.3 0.8 0.8 0.8 - - - - - -15HT 4.5 1.4 4.5 2.5 0.7 2.5 3.0 1.4 3.0 1.8 0.8 1.8 1.3 1.3 1.3 0.8 0.8 0.8 - - - - - -17HT 4.3 2.2 4.4 2.3 1.0 2.3 4.1 2.1 4.2 2.6 1.2 2.6 - - - - - - - - - - - -21HT 6.2 4.0 6.3 3.2 2.0 3.2 5.7 4.7 5.7 3.7 3.1 3.7 - - - - - - - - - - - -4H

-15

2.4 0.5 2.7 1.2 0.2 1.4 2.3 0.4 2.6 1.2 0.2 1.4 1.2 0.4 1.2 0.7 0.2 0.7 - - - - - -6H 3.2 0.6 3.3 1.4 0.2 1.5 3.2 0.6 3.2 1.5 0.3 1.6 1.6 0.6 1.6 0.9 0.3 0.9 - - - - - -8H 3.2 0.7 3.7 1.3 0.3 1.9 3.4 0.7 3.6 1.6 0.3 2.2 0.8 0.7 0.8 0.4 0.3 0.4 - - - - - -12H 6.4 2.0 7.3 2.8 0.8 3.2 6.0 1.8 6.8 2.9 0.9 3.3 2.9 1.7 2.9 1.7 1.0 1.7 - - - - - -12HT 6.7 1.7 7.5 2.7 0.7 3.0 6.4 1.8 7.2 3.5 0.8 4.0 2.9 1.7 2.9 1.7 0.9 1.7 - - - - - -15H 7.4 1.6 8.3 3.1 0.7 3.6 7.1 1.6 8.0 3.4 0.7 3.9 3.0 1.5 3.0 1.7 0.9 1.7 - - - - - -15HT 7.4 1.8 8.4 3.0 0.7 3.4 7.1 1.6 8.0 3.9 0.8 4.5 3.0 1.6 3.0 1.7 0.9 1.7 - - - - - -17HT 5.1 2.6 5.0 2.5 1.1 2.5 4.8 2.4 4.8 2.8 1.3 2.8 - - - - - - - - - - - -21HT 7.4 4.8 7.4 3.4 2.1 3.4 6.9 5.7 6.9 4.0 3.3 4.0 - - - - - - - - - - - -4H

-7

2.5 0.5 2.8 1.0 0.2 1.2 2.4 0.5 2.6 1.1 0.2 1.3 2.4 0.4 2.5 1.4 0.2 1.4 2.2 0.4 2.5 1.3 0.2 1.46H 3.4 0.6 3.5 1.4 0.2 1.5 3.5 0.6 3.5 1.6 0.3 1.7 3.3 0.6 3.3 1.7 0.3 1.8 3.0 0.6 3.1 1.8 0.3 1.98H 3.8 0.8 4.2 1.4 0.3 2.0 3.9 0.8 4.0 1.7 0.3 2.4 3.6 0.7 4.0 1.9 0.4 2.4 1.8 0.7 2.2 1.2 0.4 1.412H 6.9 2.1 7.4 2.8 0.8 3.0 6.6 2.0 7.5 3.0 0.9 3.5 6.4 1.9 7.2 3.5 1.1 4.0 6.1 1.9 6.9 3.9 1.2 4.512HT 7.1 1.9 8.7 2.7 0.7 3.5 5.9 1.8 8.7 2.6 0.8 4.0 5.8 1.7 7.0 3.1 0.9 3.8 5.4 1.5 6.7 3.5 1.0 4.415H 7.8 1.8 9.1 3.1 0.7 3.7 7.7 1.8 9.1 3.5 0.8 4.2 7.4 1.7 7.9 4.0 0.9 4.6 6.6 1.5 7.6 4.0 0.9 4.715HT 8.0 1.9 9.5 3.1 0.7 3.9 8.0 1.8 9.4 3.5 0.8 4.4 6.5 1.7 7.9 3.5 0.9 4.5 6.7 1.5 7.5 4.4 1.0 5.317HT 7.1 2.4 10.3 3.0 0.9 5.0 6.8 2.2 9.9 3.4 1.0 5.7 7.0 2.1 8.3 3.7 1.2 4.6 6.8 2.1 6.9 3.9 1.2 4.021HT 10.2 6.4 15.0 4.0 2.3 6.7 9.5 7.4 14.4 4.7 3.6 7.9 8.9 6.9 11.1 5.5 4.3 7.0 - - - - - -4H

-3

2.8 0.6 3.1 1.1 0.2 1.1 2.7 0.5 3.0 1.1 0.2 1.3 2.8 0.5 2.8 1.4 0.2 1.5 2.6 0.4 2.8 1.3 0.2 1.56H 3.8 0.7 3.8 1.4 0.2 1.4 3.8 0.7 3.8 1.6 0.3 1.7 3.7 0.7 3.8 1.8 0.3 1.9 3.4 0.6 3.5 1.9 0.3 2.08H 4.4 0.9 4.8 1.6 0.3 2.0 4.5 0.9 4.8 1.9 0.3 2.6 4.2 0.8 4.6 2.1 0.4 2.6 2.1 0.7 2.5 1.2 0.4 1.512H 7.8 2.4 8.9 2.7 0.8 3.1 7.4 2.3 8.4 3.2 1.0 3.7 7.4 2.3 8.4 3.8 1.1 4.3 6.9 2.1 7.8 4.1 1.2 4.712HT 7.7 2.1 9.5 2.7 0.7 3.5 6.2 2.0 9.4 2.6 0.8 4.1 6.4 1.9 7.5 3.2 0.9 3.8 5.9 1.7 7.4 3.8 1.1 4.815H 9.0 2.0 10.2 3.2 0.7 3.7 9.0 2.0 10.2 3.8 0.8 4.4 8.0 1.9 8.4 4.0 0.9 4.5 6.8 1.7 7.9 3.8 1.0 4.515HT 8.5 2.1 10.5 3.1 0.7 3.9 8.4 2.0 10.5 3.5 0.8 4.6 6.9 1.9 8.7 3.4 0.9 4.6 7.3 1.7 8.3 4.8 1.1 5.717HT - - - - - - - - - - - - - - - - - - - - - - - -21HT - - - - - - - - - - - - - - - - - - - - - - - -4H

0

2.9 0.6 3.3 1.0 0.2 1.1 2.8 0.6 3.2 1.1 0.2 1.3 3.0 0.5 3.1 1.5 0.2 1.5 2.8 0.5 3.0 1.4 0.2 1.66H 4.0 0.7 4.1 1.3 0.2 1.4 4.0 0.7 4.0 1.7 0.3 1.8 4.0 0.7 4.0 1.9 0.3 1.9 3.7 0.7 3.8 1.9 0.3 2.18H 4.7 1.0 5.2 1.6 0.3 2.1 4.8 1.0 5.2 2.0 0.4 2.6 4.5 0.9 5.0 2.2 0.4 2.7 2.2 0.8 2.7 1.3 0.4 1.612H 8.5 2.6 9.6 2.8 0.8 3.2 8.1 2.4 9.1 3.3 1.0 3.8 8.2 2.5 9.1 4.0 1.2 4.4 7.5 2.3 8.5 4.3 1.3 4.912HT 7.9 2.3 9.9 2.8 0.7 3.6 6.7 2.2 9.8 2.7 0.8 4.0 6.4 2.0 8.0 3.0 0.9 3.9 6.0 1.9 7.6 3.7 1.1 4.815H 9.0 2.1 11.1 3.0 0.7 3.7 9.7 2.1 11.1 4.0 0.8 4.6 8.3 2.0 8.7 4.0 0.9 4.5 7.0 1.9 8.2 3.8 1.0 4.515HT 8.7 2.3 11.2 3.1 0.7 4.1 8.6 2.1 11.0 3.5 0.8 4.7 7.6 2.0 9.0 3.6 0.9 4.5 7.5 1.9 8.5 4.8 1.1 5.617HT - - - - - - - - - - - - - - - - - - - - - - - -21HT - - - - - - - - - - - - - - - - - - - - - - - -

PI Power input, kW (power input values include the compressor, fans and control)HC Heating capacity, kW

Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)Condenser fluid: waterFouling factor: 0.000018 m 2 K/W

Performances in accordance with EN14511-3:2011.

Page 20: Price List 2017 - CIAT

20

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

EREBA performance tablesHeating capacities (continued)

Leaving hot water temperature, °CHeating floor Comfort unit Radiator

EREBA Outdoor air temp., °C

35 45 55 60HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW

Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max.4H

2

3.3 0.6 3.6 1.1 0.2 1.1 3.0 0.6 3.4 1.1 0.2 1.3 3.2 0.6 3.2 1.5 0.2 1.5 2.9 0.5 3.2 1.4 0.2 1.56H 4.2 0.8 4.3 1.4 0.2 1.5 4.2 0.8 4.2 1.7 0.3 1.8 4.2 0.8 4.2 1.9 0.3 1.9 3.9 0.7 4.0 1.9 0.3 2.18H 5.1 1.0 5.5 1.7 0.3 2.1 5.2 1.0 5.5 2.0 0.4 2.6 4.9 1.0 5.2 2.2 0.4 2.6 2.4 0.8 2.9 1.3 0.4 1.512H 8.8 2.9 10.1 2.8 0.9 3.3 8.5 2.7 9.6 3.2 1.0 3.7 8.7 2.7 9.6 3.9 1.2 4.4 7.9 2.5 8.9 4.3 1.3 4.912HT 8.6 2.6 11.0 2.7 0.8 3.6 7.5 2.5 10.6 2.8 0.9 4.1 7.5 2.3 8.7 3.3 1.0 4.0 7.1 2.1 8.6 3.5 1.0 4.315H 9.5 2.5 12.1 3.1 0.7 3.8 9.5 2.5 11.4 3.7 0.9 4.5 9.0 2.3 9.5 4.1 1.0 4.6 7.4 2.1 9.0 3.8 1.1 4.715HT 9.5 2.7 12.6 3.1 0.8 4.1 9.3 2.5 11.9 3.5 0.9 4.7 8.0 2.3 10.2 3.6 1.0 4.9 8.5 2.1 9.7 4.3 1.0 5.017HT 12.5 5.4 18.4 4.0 1.7 7.4 11.8 5.1 17.6 4.7 1.7 8.5 11.2 4.2 12.9 5.3 1.7 6.6 10.8 4.1 11.1 5.6 1.9 5.821HT 15.3 7.1 19.5 5.2 2.3 7.8 14.5 5.4 18.5 6.1 2.2 9.0 13.4 6.2 16.7 7.0 3.2 9.0 - - - - - -4H

7

4.1 0.8 4.7 1.0 0.2 1.2 3.9 0.7 4.5 1.2 0.2 1.4 4.1 0.7 4.2 1.5 0.2 1.6 3.8 0.6 4.2 1.5 0.2 1.76H 5.8 1.1 6.1 1.4 0.2 1.5 5.8 1.1 6.0 1.9 0.3 2.1 5.4 1.0 5.6 2.1 0.4 2.2 5.0 0.9 5.1 2.2 0.4 2.38H 7.2 1.3 8.0 1.8 0.3 2.3 7.4 1.3 7.9 2.3 0.4 2.8 6.7 1.3 7.5 2.9 0.5 3.5 3.0 1.1 3.7 1.4 0.5 1.812H 11.9 3.6 13.5 3.0 0.9 3.5 11.5 3.5 13.0 3.8 1.1 4.3 10.3 3.4 11.5 4.1 1.3 4.6 10.2 3.1 11.0 4.9 1.5 5.312HT 12.0 3.4 15.0 2.8 0.8 3.6 11.2 3.1 14.5 3.3 0.9 4.4 11.1 2.8 13.1 3.9 1.0 4.7 10.7 2.5 12.9 4.0 0.9 4.915H 14.5 3.2 16.3 3.5 0.8 4.1 14.0 3.1 15.9 4.3 0.9 5.0 11.7 2.8 12.4 4.1 1.0 4.7 10.0 2.5 11.2 4.6 1.1 5.415HT 15.0 3.4 17.4 3.6 0.8 4.2 14.5 3.1 16.5 4.4 0.9 5.1 12.0 2.8 15.3 4.2 1.0 5.8 12.8 2.5 14.5 4.9 0.9 5.717HT 16.9 3.3 21.3 4.0 0.8 6.9 15.8 4.4 20.0 4.6 1.5 7.9 15.0 4.1 17.7 5.5 1.9 6.6 14.4 3.8 15.0 5.5 2.1 5.821HT 20.7 7.4 21.7 5.0 1.7 7.3 19.5 6.6 21.1 5.9 2.0 8.5 18.7 6.2 22.8 6.9 2.3 8.9 - - - - - -4H

10

4.5 0.8 5.1 1.0 0.2 1.2 4.2 0.8 4.8 1.2 0.2 1.5 4.4 0.7 4.5 1.5 0.2 1.6 4.1 0.7 4.4 1.6 0.2 1.76H 6.3 1.2 6.7 1.4 0.2 1.5 6.2 1.1 6.5 2.0 0.3 2.1 6.0 1.1 6.1 2.2 0.4 2.3 5.3 1.0 5.3 2.2 0.4 2.28H 7.8 1.5 8.7 1.8 0.3 2.3 8.0 1.4 8.6 2.3 0.4 2.8 7.3 1.4 8.1 2.5 0.4 3.0 3.3 1.2 4.0 1.4 0.5 1.812H 12.9 3.9 14.6 3.0 0.9 3.4 12.3 3.7 13.9 3.8 1.1 4.4 11.5 3.6 12.4 4.4 1.3 4.7 10.8 3.3 11.3 4.9 1.5 5.112HT 12.9 3.7 16.1 2.7 0.8 3.5 12.0 3.3 15.9 3.5 0.9 4.7 11.9 3.0 14.3 3.9 1.0 4.9 11.6 2.6 13.8 4.1 0.9 5.015H 15.7 3.5 17.5 3.5 0.8 4.0 15.1 3.3 17.1 4.4 0.9 5.1 12.7 3.0 13.4 4.3 1.0 4.8 11.3 2.6 11.3 4.9 1.1 4.915HT 16.1 3.7 18.7 3.5 0.8 4.1 15.9 3.3 18.1 4.7 0.9 5.5 13.1 3.0 16.8 4.3 1.0 6.0 13.7 2.6 16.0 5.0 0.9 5.917HT 16.9 3.7 25.3 4.1 0.7 7.4 15.9 4.9 25.0 4.7 1.2 8.7 15.0 4.6 18.3 5.4 1.6 6.6 14.4 4.6 15.3 5.7 1.7 6.221HT 22.4 8.6 32.1 5.0 2.2 8.8 21.3 7.6 30.9 5.9 2.6 10.2 20.1 7.1 24.4 6.8 3.2 8.9 - - - - - -4H

20

5.6 1.1 6.5 1.0 0.2 1.2 5.2 1.0 6.0 1.3 0.2 1.5 5.4 1.0 5.6 1.6 0.3 1.6 4.9 0.9 5.4 1.6 0.3 1.86H 8.0 1.5 8.4 1.3 0.2 1.5 7.7 1.4 8.2 2.0 0.3 2.2 6.9 1.4 7.1 2.1 0.4 2.2 6.1 1.2 6.1 2.2 0.4 2.28H 9.9 1.8 11.0 1.8 0.3 2.3 10.0 1.8 10.8 2.3 0.4 2.8 9.1 1.7 10.1 2.6 0.5 3.1 4.0 1.4 4.8 1.5 0.5 1.812H 16.3 4.9 18.5 2.9 0.9 3.3 15.2 4.6 17.2 4.0 1.2 4.6 13.9 4.4 14.6 4.5 1.4 4.7 11.1 4.0 11.6 4.3 1.5 4.512HT 16.1 4.7 20.2 2.7 0.8 3.4 15.0 4.1 18.9 3.9 1.0 4.7 14.9 3.7 17.1 4.2 1.0 4.9 14.2 3.2 16.4 4.2 0.9 4.915H 19.9 4.4 21.7 3.4 0.7 3.7 18.6 4.1 20.4 4.6 1.0 5.1 15.0 3.7 15.8 4.3 1.0 4.8 11.9 3.1 11.9 4.8 1.1 4.815HT 20.2 4.7 23.5 3.4 0.8 4.0 18.9 4.1 21.6 4.7 1.0 5.5 15.7 3.7 20.0 4.4 1.0 6.0 16.0 3.1 19.0 4.9 0.9 5.917HT - - - - - - - - - - - - - - - - - - - - - - - -21HT - - - - - - - - - - - - - - - - - - - - - - - -

PI Power input, kW (power input values include the compressor, fans and control)HC Heating capacity, kW

Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)Condenser fluid: waterFouling factor: 0.000018 m2 K/W

Performances in accordance with EN14511-3:2011.

Page 21: Price List 2017 - CIAT

21

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

GEOCIAT PowerWater-to-water heat pump

• Heating only (optional GeoCooling).• Water outlet temperature up to 60°C.• COP certified up to 4.24.• Extra low noise level.• Two class A variable-speed accelerator pumps and 12 l expansion vessels.• Units supplied with flexible connections and filter valve kit as standard.

GEOCIAT Power 50H 50HT 65HT 90HT 120HTUnderfloor heating 30/35°C*Heating to 0/-3°C kW 12.48 12.16 15.80 21.44 27.35COP 4.15 4.24 4.21 4.06 4.24SCOP 4.34 4.41 4.44 4.24 4.31Energy class A++ A++ A++ A++ A++Heating to 10/7°C kW 16.50 16.39 21.13 27.64 37.62COP 5.31 5.42 5.32 5.25 5.43Comfort unit 40/45°C*Heating to 0/-3°C kW 12.02 11.55 15.08 20.59 25.95COP 3.31 3.33 3.30 3.24 3.32Radiators 47/55°C*Heating to 0/-3°C kW 11.90 11.80 14.80 20.50 25.80COP 2.95 3.03 2.93 2.89 2.95SCOP 3.31 3.30 3.29 3.21 3.27Energy class A+ A+ A+ A+ A+Sound power* dB(A) 54 54 52 53 55Power supply V-ph-Hz 230-1-50 400-3-50Part Number 7402076 7402079 7402080 7402081 7402083Price £ 8,210 7,900 8,161 9,538 11,083* Following conditions NFPAC. Certified data NFPAC under No. NF414-1278.

AccessoriesDescription Sizes 50H/HT-65HT Price, £ Sizes 90HT-120HT Price, £Manual valve kit (2 x required) 7110726 73 7110727 88Filling kit 7013877 92 7111810 109GeoCooling kit 7438199 1,453 7438200 1,563200 l 8-nozzle mixing tank 7328747 713 - -400 l 8-nozzle mixing tank 7328748 957 7328748 9579 kW aux heater kit to be integrated in the 8-nozzle mixing tanks 7221389 374 7221389 3745 kW (single phase) loop heater 7148641 743 - -9 kW (three phase) loop heater - - 7148642 9022-zone kit (accelerator pump, 3-way valve, thermometers, HomeConnect expansion board, wireless IO Homecontrol sensor)

7438198 1,318 7438198 1,318

HomeConnect expansion board 7438336 304 7438336 304Pool heating kit (sensor + 3-way valves) 7111122 435 7111122 435UFHC limiter thermostat (60°C) 7274278 68 7274278 68300 l domestic hot water tank (sensor and 3-way valve) 7411502 1,602 - -Outdoor sensor with radio signal (to replace the wired outdoor sensor) 7262090 92 7262090 92Offset sensor (10 m) 7438175 147 7438175 147Sectional heat exchanger ITEX AGEO (water-to-water operation) 7268481 824 7268481 824

3-Year Warranty Available

Page 22: Price List 2017 - CIAT

22

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

GEOCIAT Power performance tablesLeaving hot water temperature, °C

Heating floor Comfort unit RadiatorGEOCIAT Power

Leaving chilled water temp., °C

30 35 40 45 50 55 60PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW

50H

40% glycol solution

-6

2.7 11.4 3.0 11.2 3.3 11.1 3.6 10.8 4.0 10.7 - - - -50HT 2.6 11.2 2.9 11.1 3.2 10.9 3.4 10.7 3.8 10.5 - - - -65HT 3.4 14.4 3.7 14.2 4.0 13.9 4.5 13.6 4.9 13.0 - - - -90HT 4.7 19.6 5.2 19.2 5.8 18.9 6.3 18.6 7.0 18.3 - - - -120HT 5.7 24.7 6.3 24.3 7.0 23.9 7.7 23.5 8.6 23.1 - - - -50H

-4

2.7 12.1 3.0 11.9 3.4 11.7 3.6 11.5 4.0 11.3 - - - -50HT 2.6 11.9 2.9 11.8 3.2 11.6 3.5 11.3 3.8 11.1 - - - -65HT 3.4 15.3 3.7 15.1 4.1 14.8 4.5 14.4 5.0 13.9 - - - -90HT 4.8 20.8 5.3 20.5 5.8 20.1 6.3 19.7 7.1 19.4 - - - -120HT 5.8 26.2 6.4 25.9 7.0 25.4 7.8 24.9 8.7 24.4 - - - -50H

-2

2.7 12.8 3.0 12.6 3.4 12.4 3.7 12.2 4.0 11.9 - - - -50HT 2.6 12.7 2.9 12.5 3.2 12.3 3.5 12.0 3.9 11.8 - - - -65HT 3.5 16.3 3.8 16.0 4.2 15.7 4.6 15.3 5.0 14.8 - - - -90HT 4.8 22.2 5.3 21.7 5.9 21.3 6.4 12.0 7.1 20.5 - - - -120HT 5.9 27.9 6.4 27.4 7.1 26.9 7.9 26.4 8.8 25.8 - - - -50H

0

2.8 13.6 3.1 13.4 3.4 13.2 3.7 12.9 4.1 12.6 4.5 12.3 - -50HT 2.7 13.5 2.9 13.3 3.2 13.0 3.5 12.7 3.9 12.5 4.3 12.2 - -65HT 3.5 17.3 3.9 17.0 4.2 16.6 4.7 16.3 5.1 15.8 5.8 15.4 - -90HT 4.9 23.6 5.4 23.2 5.9 22.6 6.4 22.3 7.1 21.7 8.0 21.0 - -120HT 6.0 29.6 6.5 29.2 7.2 28.4 8.0 28.0 8.9 27.4 9.9 26.7 - -50H

2

2.8 14.5 3.1 14.3 3.4 14.0 3.7 13.6 4.1 13.3 4.5 13.0 - -50HT 2.7 14.4 3.0 14.1 3.3 13.9 3.6 13.4 4.0 13.1 4.4 12.9 - -65HT 3.6 18.4 3.9 18.0 4.3 17.7 4.7 17.2 5.2 16.7 5.9 16.4 - -90HT 5.0 25.1 5.4 24.6 6.0 24.1 6.4 23.5 7.2 22.9 8.0 22.1 - -120HT 6.0 31.6 6.6 30.9 7.3 30.2 8.1 29.5 8.9 28.8 9.9 28.1 - -50H

Pure water

5

2.8 16.2 3.1 15.9 3.3 15.6 3.7 15.1 4.1 14.7 4.6 14.3 5.1 13.950HT 2.7 16.1 3.0 15.8 3.3 15.4 3.7 15.0 4.1 14.6 4.5 14.2 5.0 13.865HT 3.5 20.6 3.8 20.1 4.3 19.5 4.7 19.0 5.2 18.4 5.7 18.1 6.2 17.490HT 4.9 27.9 5.3 27.2 5.9 26.6 6.6 25.8 7.3 25.1 8.0 24.6 9.0 23.8120HT 6.1 35.8 6.6 34.9 7.3 34.0 8.1 33.1 9.0 32.2 10.0 31.2 11.2 30.350H

6

2.8 16.7 3.1 16.3 3.4 15.9 3.7 15.5 4.2 15.1 4.6 14.7 5.1 14.350HT 2.7 16.7 3.0 16.2 3.4 15.7 3.7 15.4 4.1 15.0 4.6 14.6 5.0 14.165HT 3.5 21.2 3.8 20.7 4.4 19.9 4.8 19.5 5.2 18.9 5.7 18.6 6.2 17.890HT 4.9 28.8 5.4 28.1 6.1 27.1 6.6 26.6 7.4 25.8 8.1 25.3 9.0 24.4120HT 6.1 36.9 6.7 35.9 7.5 34.7 8.1 34.0 9.1 33.0 10.1 32.1 11.2 31.050H

7

2.8 17.2 3.1 16.8 3.5 16.4 3.8 16.0 4.2 15.5 4.6 15.1 5.1 14.650HT 2.7 17.1 3.0 16.7 3.4 16.1 3.7 15.9 4.1 15.4 4.6 14.9 5.0 14.565HT 3.5 21.9 3.9 21.2 4.4 20.4 4.8 20.0 5.2 19.3 5.7 19.0 6.2 18.290HT 5.0 29.7 5.4 28.8 6.1 27.9 6.7 27.3 7.4 26.5 8.1 26.0 9.0 25.0120HT 6.2 38.0 6.7 36.9 7.6 35.7 8.2 35.0 9.1 33.9 10.1 32.8 11.3 31.850H

8

2.8 17.8 3.1 17.3 3.5 16.9 3.8 16.4 4.2 15.9 4.7 15.5 5.1 15.050HT 2.7 17.7 3.0 17.2 3.5 16.6 3.7 16.3 4.1 15.8 4.6 15.4 5.1 14.965HT 3.5 22.6 3.9 21.8 4.4 21.0 4.8 20.5 5.2 19.8 5.8 19.6 6.3 18.790HT 5.0 30.6 5.4 29.7 6.2 28.7 6.7 28.0 7.4 27.2 8.1 26.7 9.1 25.6120HT 6.2 39.1 6.8 38.0 7.7 36.8 8.3 35.8 9.2 34.8 10.2 33.7 11.3 32.550H

10

2.9 18.8 3.2 18.4 3.5 17.8 3.9 17.1 4.2 16.8 4.7 16.3 5.2 15.850HT 2.8 18.7 3.1 18.2 3.5 17.6 3.9 17.0 4.2 16.7 4.6 16.2 5.1 15.665HT 3.5 23.9 3.9 23.1 4.4 22.2 5.0 21.4 5.3 20.9 5.8 20.6 6.3 19.790HT 5.1 32.5 5.5 31.5 6.2 30.4 7.0 29.3 7.5 28.6 8.2 28.2 9.1 26.9120HT 6.3 41.4 6.9 40.3 7.7 38.9 8.7 37.4 9.3 36.6 10.3 35.4 11.4 34.250H

12

2.9 20.0 3.2 19.4 3.5 18.8 3.8 18.3 4.1 17.8 4.7 17.1 5.2 16.650HT 2.8 19.9 3.1 19.2 3.5 18.6 3.8 18.2 4.1 17.7 4.7 17.0 5.1 16.465HT 3.5 25.4 3.9 24.4 4.4 23.4 4.8 22.8 5.2 22.1 5.8 21.6 6.3 20.790HT 5.1 34.6 5.7 33.2 6.3 32.1 6.8 31.3 7.4 30.4 8.3 29.7 9.2 28.3120HT 6.4 44.0 7.0 42.5 7.8 41.1 8.4 40.0 9.2 38.8 10.4 37.2 11.5 35.950H

15

3.0 21.8 3.3 21.1 3.6 20.5 3.9 19.8 4.3 19.1 4.7 18.5 5.2 17.950HT 2.9 21.6 3.2 20.9 3.5 20.3 3.8 19.7 4.3 19.0 4.7 18.4 5.2 17.865HT 3.5 27.7 3.9 26.5 4.4 25.5 4.9 24.6 5.4 23.7 5.9 23.3 6.4 22.390HT 5.4 37.7 5.9 36.1 6.4 35.0 7.0 33.9 7.7 32.7 8.4 32.4 9.3 30.5120HT 6.7 47.8 7.1 46.2 7.8 44.8 8.6 43.3 9.6 41.7 10.6 40.3 11.6 38.750H

18

3.1 23.8 3.3 23.1 3.7 22.3 4.0 21.5 4.4 20.7 4.8 20.0 5.3 19.350HT 2.9 23.6 3.2 22.8 3.6 22.1 3.9 21.4 4.3 20.6 4.7 19.9 5.2 19.265HT 3.5 30.3 3.9 28.9 4.4 27.7 4.9 26.6 5.4 25.6 5.9 25.1 6.4 24.190HT 5.5 41.3 6.0 39.4 6.6 38.1 7.2 36.7 7.8 35.4 8.5 35.1 9.4 32.9120HT 6.9 52.1 7.3 50.4 8.0 48.7 8.7 46.9 9.7 45.1 10.7 43.5 11.8 41.750H

20

3.1 25.2 3.4 24.4 3.7 23.5 4.0 22.7 4.4 21.9 4.8 21.0 5.3 20.350HT 3.0 25.0 3.3 24.1 3.6 23.4 4.0 22.6 4.4 21.8 4.8 20.9 5.2 20.265HT 3.6 32.1 4.0 30.6 4.4 29.2 4.9 28.1 5.4 27.0 5.9 26.4 6.4 25.390HT 5.6 43.8 6.2 41.7 6.6 40.3 7.3 38.8 7.9 37.4 8.6 37.1 9.4 34.5120HT 7.1 55.2 7.5 53.4 8.1 51.6 8.8 49.6 9.7 47.7 10.8 45.7 11.9 43.8

PI Power input, kW (power input values include the compressor, fans and control) HC Heating capacity, kW

Page 23: Price List 2017 - CIAT

23

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

GEOCIAT AccessGeothermal heat pump

• Comprehensive packaged unit.• GeoCooling as standard.• R410A scroll compressor.• Brazed plate heat exchanger.• Hydraulic module with class A variable-speed accelerator pumps and

expansion vessel.• Domestic hot water valve integrated as standard (300 l tank optional).• HomeConnect control with remote control station.• Units supplied with flexible connections and filter valve kit as standard.

GEOCIAT Access 18HUnderfloor heating 30/35°C*Heating to 0/-3°C kW 4.74COP 4.11SCOP 4.35Energy class A++Fan coil unit 40/45°C*Heating to 0/-3°C kW 4.48COP 3.23Radiators 47/55°C*Heating to 0/-3°C kW 4.19COP 2.60SCOP 3.14Energy class A+Maximum leaving water temperature °C 62Sound power* dB(A) 53Power supply V-ph-Hz 230-1-50Double Service hot water supply from 300 l tank**Tank capacity l 300Withdrawing cycle XLHot water temperature °C 54.2COP 2.72Part Number 7368964Price £ 5,603* Following conditions NFPAC. Certified data NFPAC under No. NF414-11385E/1068.** Following conditions NFPAC Double Service. Certified data NFPAC under No. NF414-1386E/1069.

3-Year Warranty Available

Page 24: Price List 2017 - CIAT

24

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

GEOCIAT Access accessoriesAccessoriesDescription Part Number Price, £1” filling kit* (2 x required) 7013876 811” manual valve kit* (2 x required) 7110700 92Kit for 4 kW GEOCIAT Access 7396343 420HomeConnect expansion board 7371947 2852-zone kit** 7367399 1,091Hygrometric probe for PCR** 7076818 191Offset sensor (10 m) 7438175 147Outdoor sensor with radio signal 7262090 92Floor limit thermostat (60°C) 7274278 68* Primary and secondary kit supplied** Options controlled by one HomeConnect expansion board

GEOCIAT Access performance tablesGEOCIAT Access

Leaving chilled water temperature, °C

30 35 40 45 50 55 60 62PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW

18H

40% glycol solution

-6 1.00 4.21 1.11 4.20 1.22 4.21 1.34 4.13 1.47 4.05 1.62 3.99 1.77 3.91 1.84 3.89-4 1.01 4.56 1.11 4.51 1.23 4.44 1.36 4.38 1.48 4.30 1.63 4.23 1.79 4.14 1.83 4.09-3 1.01 4.73 1.12 4.66 1.24 4.60 1.37 4.50 1.50 4.43 1.64 4.34 1.80 4.26 1.87 4.22-2 1.02 4.89 1.12 4.85 1.24 4.74 1.37 4.64 1.51 4.56 1.66 4.46 1.81 4.37 1.88 4.330 1.02 5.23 1.13 5.12 1.25 5.01 1.39 4.93 1.53 4.81 1.68 4.71 1.84 4.59 1.92 4.552 1.02 5.55 1.14 5.43 1.27 5.31 4.41 5.21 1.54 5.08 1.71 4.95 1.87 4.84 1.95 4.79

Pure water

5 0.98 6.10 1.11 6.00 1.24 5.84 1.37 5.69 1.54 5.54 1.71 5.38 1.89 5.24 1.97 5.166 0.98 6.35 1.11 6.16 1.24 6.02 1.38 5.84 1.55 5.70 1.72 5.54 1.91 5.34 1.98 5.277 0.98 6.52 1.11 6.35 1.25 6.19 1.39 6.02 1.55 5.84 1.72 5.67 1.92 5.47 1.99 5.418 0.98 6.70 1.11 6.54 1.25 6.36 1.39 6.21 1.55 6.00 1.73 5.79 1.92 5.60 2.00 5.5410 0.97 7.08 1.11 6.91 1.25 6.71 1.40 6.53 1.56 6.31 1.74 6.11 1.94 5.89 2.03 5.8012 0.97 7.49 1.10 7.28 1.25 7.07 1.41 6.89 1.58 6.63 1.75 6.42 1.96 6.17 2.04 6.0815 0.95 8.14 1.10 7.90 1.25 7.66 1.42 7.40 1.58 7.15 1.78 6.90 1.98 6.63 2.08 6.5218 0.94 8.68 1.09 8.40 1.25 8.08 1.42 7.79 1.60 7.49 1.78 7.19 1.99 6.87 2.08 6.76

PI Power input, kW (power input values include the compressor, fans and control)HC Heating capacity, kW

Page 25: Price List 2017 - CIAT

25

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIAT CaleoAir-to-water heat pump

• Water outlet temperature 65°C at -12°C.• Winter operation (-20°C).• High energy efficiency (COP).• Compact and quiet.• Scroll compressors.• Self-adjusting electronic control.

AQUACIAT Caleo 80Z 100Z 120Z 150ZNet heating capacity* kW 24.8 34.7 40.8 47.3COP* 3.63 3.75 3.92 3.83SCOP 2.97 2.32 3.31 3.34P-rated/Energy class kW 14.5/A 19.6/A+ 24.1/A+ 28.4/A+Heating capacity** kW 25.9 34.7 43.1 48.7COP** 2.63 2.62 2.71 2.81SCOP 2.57 2.77 2.82 2.83P-rated/Energy glass kW 14.8/A+ 20.9/A+ 25.7/A+ 30.1/A+Refrigerant charge (R407C) kg 7.2 11.5 18.0 18.0Expansion tank capacity l 18 18 18 18Minimum system water volume l 227 319 374 434Max. system capacity***- pure water at 65°C/90°C- 40% glycol/water mix at 65°C/90°C

l450/250275/185

450/250275/185

450/250275/185

450/250275/185

No. of fan speeds/available pressure kPa 1/145 1/115 1/140 1/135Minimum/maximum water flow rate m3/h 3.2/7.6 3.9/8.5 4.4/12.2 4.9/13.0Operating limits (winter/summer) °C -20/45 -20/45 -20/45 -20/45Maximum leaving water temperature °C 65 65 65 65Sound pressure level (high temperature) dB(A) 77 77 77 77System current A 22.2 27.1 31.0 36.3Starting current (with SoftStart) A 99 (59) 127 (76) 167 (100) 198 (119)Part Number 7223410 7223409 7223408 7223406Price £ 12,955 15,563 16,993 18,928* Heating capacities in high performance version at the unit outlet, based on hot water outlet at 35°C and outside air 7°C DB 86% RH.** Heating capacities in high performance version at the unit outlet, based on hot water outlet at 45°C and outside air 7°C DB 86% RH.*** For temperatures outside of this, an additional expansion tank is required.

AccessoriesDescription Part Number Price, £1-1/2” flexible customer kit 7187605 147SoftStart kit 7272062 290/650 (150Z)Phase monitor kit (reversal, loss, over- and undervoltage) 7081668 2011-1/2” filling kit* 7111810 101Electrical auxiliary unit by 9 kW loop heater supplied separately 7148642 836Electrical auxiliary unit by 15 kW loop heater supplied separately 7272405 994Hydraulic control kit (pressure gauges, control & shut-off valve) 3911008 1,264200 litre 8-nozzle mixing tank 7328747 661400 litre 8-nozzle mixing tank 7328748 8879 kW electrical auxiliary kit to be integrated into the 200 or 400 litre 8-nozzle mixing tank 7221389 347Pool heating kit with motorised 3-way valves 7111122 403DHW heating kit (2 x 300 litre tanks in parallel) and motorised 3-way valves 2 x 7385910 + 7411357 2,969Safety hot water thermostat kit (60°C) 7101578 54Frost protection 7090373 200

Extended Warranty Available

Page 26: Price List 2017 - CIAT

26

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AQUACIAT Caleo performance tablesHeating capacitiesAQUACIAT Caleo

Outdoor air temp., °C

Leaving hot water temperature, °C25 30 35 40 45 50 55 60 65

HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW

80Z

-20 9.7 4.9 9.9 5.1 10.1 5.6 10.2 5.9 10.5 6.5 10.2 6.9 - - - - - --15 11.6 5.1 11.8 5.4 12.2 5.8 12.2 6.1 12.3 6.7 12.9 7.3 13.0 8.1 12.3 8.8 - --10 13.4 5.3 13.8 5.6 14.2 6.0 14.5 6.4 14.7 6.9 14.9 7.6 14.8 8.4 14.5 9.3 13.8 10.1-7 14.5 5.4 14.9 5.7 15.4 6.2 15.7 6.6 15.9 7.1 16.1 7.8 15.8 8.6 15.7 9.5 15.2 10.3-5 15.7 5.5 16.1 5.8 16.5 6.2 17.0 6.8 17.2 7.3 17.7 8.0 17.4 8.8 17.0 9.7 16.6 10.40 18.5 5.7 19.1 6.0 19.2 6.5 19.6 7.0 20.3 7.6 20.7 8.4 20.5 9.2 19.7 10.1 19.1 10.85 22.3 5.8 22.9 6.1 23.8 6.7 24.2 7.2 24.6 8.0 24.9 8.8 24.6 9.6 23.7 10.6 23.0 11.07 23.1 5.8 23.9 6.1 24.7 6.7 24.8 7.3 25.1 8.1 25.9 9.1 25.7 9.7 25.1 10.8 24.3 11.210 25.1 5.9 25.3 6.2 25.5 6.8 26.6 7.4 27.2 8.2 27.1 9.2 27.1 9.9 26.2 11.0 25.5 11.415 27.7 5.9 27.9 6.3 28.6 6.9 28.9 7.6 29.8 8.5 30.3 9.4 30.5 10.4 30.0 11.4 29.2 11.820 29.5 6.0 29.7 6.4 30.7 6.9 31.0 7.6 31.5 8.6 31.7 9.5 32.2 10.6 31.7 11.5 31.2 12.025 30.6 6.0 31.5 6.5 32.1 7.0 32.9 7.8 33.5 8.7 33.8 9.6 33.9 10.8 33.3 11.7 32.6 12.130 31.8 6.2 32.6 6.6 33.8 7.2 34.6 7.8 36.0 8.8 36.3 9.8 36.2 11.0 35.7 12.2 35.1 12.635 33.2 6.3 34.6 6.8 35.9 7.5 37.6 8.0 38.7 9.1 40.0 10.1 39.9 11.2 39.8 12.6 39.1 13.240 - - - - 37.5 7.7 38.5 8.2 40.2 9.4 41.0 10.3 41.2 11.5 40.8 12.9 39.7 13.545 - - - - 38.5 7.9 40.2 8.4 41.6 9.6 42.6 10.5 42.7 11.9 41.8 13.1 40.5 13.7

100Z

-20 13.9 6.2 14.0 6.7 14.1 7.2 14.7 7.7 14.9 8.4 15.1 9.4 - - - - - --15 16.6 6.5 16.8 7.0 17.0 7.4 17.4 8.0 17.7 8.7 18.0 9.7 17.8 10.7 17.4 11.8 - --10 19.0 6.7 19.4 7.2 19.6 7.7 20.0 8.4 20.3 9.1 20.2 10.0 20.1 11.1 19.6 12.4 18.9 13.5-7 20.3 6.9 20.6 7.3 21.1 7.9 21.4 8.6 22.1 9.4 22.5 10.3 22.0 11.5 21.6 12.7 21.2 14.0-5 22.2 7.0 22.5 7.5 22.7 8.1 22.9 8.8 23.1 9.6 23.7 10.6 23.5 11.9 23.0 12.9 22.4 14.10 26.0 7.2 26.4 7.8 26.7 8.5 26.8 9.2 27.2 10.0 27.3 11.2 26.9 12.2 26.4 13.5 26.0 14.55 32.2 7.5 33.1 8.1 33.2 8.9 33.6 9.6 33.9 10.5 34.2 11.7 33.0 12.8 32.5 14.0 30.9 14.77 33.7 7.6 34.2 8.3 34.5 9.0 34.7 9.8 35.5 10.7 35.7 11.8 34.5 13.0 33.4 14.2 32.8 14.910 38.5 7.8 38.6 8.5 38.9 9.2 39.1 10.1 39.4 11.0 39.6 12.2 37.9 13.3 36.3 14.6 35.6 15.015 41.4 8.0 42.1 8.6 42.2 9.5 42.3 10.4 43.0 11.4 43.1 12.5 41.4 13.7 39.5 14.9 38.7 15.320 44.1 8.2 45.1 8.7 45.9 9.6 46.2 10.5 46.4 11.5 46.6 12.6 44.9 13.8 42.3 15.0 41.8 15.425 45.7 8.3 47.0 8.9 47.9 9.8 48.2 10.6 48.4 11.6 48.5 12.7 47.1 14.0 45.2 15.1 44.5 15.630 47.4 8.5 48.7 9.2 49.7 10.1 50.6 11.0 51.5 11.9 51.6 13.0 50.5 14.3 48.8 15.4 48.2 16.235 49.6 8.7 51.7 9.5 52.9 10.4 53.7 11.2 54.9 12.3 55.6 13.4 54.9 14.8 54.0 16.1 52.8 16.640 - - - - 54.2 10.7 55.0 11.5 56.3 12.6 57.2 13.7 56.6 15.1 55.5 16.5 54.2 17.045 - - - - 55.8 11.1 56.6 11.8 57.8 12.8 58.4 14.0 58.0 15.6 56.7 16.9 55.7 17.4

120Z

-20 14.7 7.2 14.9 7.6 15.3 8.2 15.5 8.8 15.8 9.9 15.7 11.0 - - - - - --15 19.0 7.7 19.2 8.3 19.5 8.7 20.0 9.5 20.3 10.5 20.6 11.5 20.5 12.8 20.0 14.2 - --10 21.6 8.0 23.0 8.6 23.7 9.2 24.0 10.1 24.1 11.0 24.2 12.0 24.0 13.5 23.5 14.7 22.7 15.2-7 25.0 8.2 26.2 8.7 26.7 9.5 26.9 10.3 27.0 11.5 27.0 12.3 26.9 13.8 25.6 15.0 24.9 15.6-5 26.9 8.3 28.0 8.8 28.9 9.7 29.3 10.6 29.4 11.8 30.2 12.8 29.6 14.1 28.9 15.3 28.1 16.30 29.9 8.5 31.7 8.9 32.7 9.9 33.1 11.0 33.3 12.3 33.4 13.4 33.5 14.8 32.8 15.7 31.8 16.75 34.7 8.6 39.1 9.2 40.1 10.1 39.4 11.4 40.6 12.7 40.9 14.1 40.7 15.4 40.8 16.5 39.2 17.27 37.8 8.7 40.4 9.3 40.6 10.2 42.1 11.6 42.6 12.9 43.3 14.3 43.0 15.7 44.0 16.9 43.1 17.410 40.2 8.8 42.1 9.3 42.8 10.3 43.6 11.8 45.3 13.1 45.5 14.6 45.2 16.0 45.0 17.2 44.2 17.615 42.9 8.9 44.8 9.5 45.5 10.5 46.8 11.9 48.4 13.3 49.4 14.9 49.2 16.3 49.0 17.5 48.5 17.820 44.7 9.1 46.8 9.6 48.0 10.7 49.4 12.0 51.0 13.4 51.7 14.9 51.5 16.4 51.3 17.7 50.3 18.025 48.0 9.3 49.5 9.8 51.1 10.8 51.7 12.1 52.6 13.5 54.0 15.0 53.8 16.6 53.3 17.8 52.4 18.030 51.0 9.5 51.7 10.0 53.0 11.0 53.9 12.3 55.4 13.6 56.6 15.1 56.4 16.7 55.8 18.0 54.5 18.435 53.7 9.8 54.5 10.2 56.3 11.4 57.9 12.6 59.5 13.8 60.9 15.2 60.5 16.9 60.1 18.3 59.0 19.040 - - - - 58.1 11.9 59.3 12.9 61.5 14.0 62.8 15.5 63.0 17.3 63.3 18.7 62.2 19.545 - - - - 59.8 12.5 61.2 13.1 63.3 14.1 65.8 15.6 66.2 17.6 66.5 19.1 65.8 20.1

150Z

-20 17.0 8.6 17.8 9.1 18.8 9.5 19.7 10.1 19.9 10.7 19.7 11.6 - - - - - --15 20.3 8.8 21.6 9.4 22.4 10.0 22.7 10.5 23.6 11.2 25.0 12.6 24.7 13.8 24.0 15.5 - --10 25.1 9.2 26.5 9.7 27.9 10.6 28.0 11.3 28.4 12.2 28.4 13.0 27.3 14.6 27.2 16.0 26.3 17.8-7 29.1 9.5 29.7 10.0 30.0 10.9 30.4 11.6 30.8 12.5 31.1 13.4 30.2 15.1 29.9 16.4 29.1 18.0-5 31.8 9.7 32.2 10.3 32.4 11.2 32.5 12.0 32.7 12.9 33.1 13.9 32.9 15.5 32.6 17.1 31.3 18.30 36.0 9.9 37.5 10.8 37.7 11.6 38.2 12.6 38.6 13.7 38.8 14.7 38.2 16.3 37.3 17.8 36.6 19.05 42.1 10.0 43.8 11.0 44.8 12.1 45.5 13.2 46.0 14.2 46.6 15.5 46.0 16.9 45.7 18.4 44.7 19.37 46.5 10.1 46.8 11.1 47.1 12.2 48.4 13.4 48.8 14.6 49.3 15.7 48.5 17.2 48.3 18.8 46.6 19.510 50.7 10.1 51.5 11.2 52.9 12.4 53.3 13.7 53.5 14.9 53.8 16.1 53.9 17.5 52.1 19.3 50.8 19.915 54.8 10.2 55.9 11.3 57.1 12.6 57.6 13.9 57.8 15.2 58.6 16.5 58.2 18.0 57.0 19.7 56.6 20.220 56.6 10.3 57.9 11.4 59.2 12.7 59.6 14.0 59.9 15.3 60.2 16.7 59.7 18.2 58.6 19.9 57.4 20.225 58.1 10.5 59.0 11.5 60.8 12.7 61.7 14.1 61.7 15.4 61.5 16.8 61.5 18.4 60.2 20.0 58.6 20.330 61.9 10.7 63.0 11.6 63.5 12.8 63.9 14.2 64.3 15.5 64.5 17.0 63.9 18.6 62.5 20.1 61.8 20.435 64.4 11.2 65.5 12.1 66.6 13.0 68.3 14.7 68.6 15.7 68.9 17.4 69.1 19.2 66.7 20.4 66.1 20.640 - - - - 68.5 13.4 71.2 15.1 72.4 16.2 73.0 18.0 73.1 19.9 72.1 21.1 70.9 22.345 - - - - 70.9 13.9 73.8 15.5 75.1 16.9 76.1 18.5 75.9 20.7 75.8 22.2 74.4 23.5

PI Power input, kW (power input values include the compressor and fan, and defrost cycles)HC Heating capacity, kW

Condenser entering/leaving water temperature difference: 5 KCondenser fluid: waterFouling factor: 0.00005 m2 K/W

Page 27: Price List 2017 - CIAT

27

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIATAir-cooled liquid chillers

• Screwed connection sleeves as standard.• Anti-vibration mounts as standard.• Micro Channel Heat Exchanger (MCHE).• Connect Touch controller as standard.

AQUACIAT chiller model LD0150A LD0180A LD0200A LD0240A LD0260A LD0300ANominal capacity* kW 40 44 51 58 67 79EER kW/kW 2.87 2.76 2.67 2.66 2.72 2.7ESEER kW/kW 3.75 3.88 3.95 3.8 3.62 3.67Eurovent class C C D D C CSound power** dB(A) 80 81 81 81 87 87Sound pressure at 10 m*** dB(A) 49 49 49 49 55 55Sound power extra low noise option** dB(A) 79 80 80 80 80 80Sound pressure at 10 m extra low noise option*** dB(A) 48 48 48 48 48 48Width x length mm 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)Weight - standard unit kg 422 430 436 449 445 463Compressors Scroll 2 2 2 2 2 2Minimum output % 50 50 50 50 50 50Maximum total air flow l/s 3885 3883 3687 3908 5013 5278Part Number 7490506 7490507 7490508 7490509 7490510 7490511Price (chiller only)**** £ 9,564 10,035 10,717 12,504 13,650 15,518

Part Number with AquaPack† 7490506-AP 7490507-AP 7490508-AP 7490509-AP 7490510-AP 7490511-APPrice (chiller with AquaPack) £ 14,639 15,110 15,793 17,580 18,725 20,594

AQUACIAT chiller model LD0360A LD0390A LD0450A LD0520A LD0600ANominal capacity* kW 87 97 114 135 156EER kW/kW 2.73 2.73 2.67 2.7 2.65ESEER kW/kW 3.91 3.94 3.83 3.68 3.87Eurovent class C C D C DSound power** dB(A) 84 84 84 90 90Sound pressure at 10 m*** dB(A) 52 52 52 58 58Sound power extra low noise option** dB(A) 83 83 83 83 83Sound pressure at 10 m extra low noise option*** dB(A) 51 51 51 51 51Width x length mm 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)Weight - standard unit kg 753 762 771 829 854Compressors Scroll 3 3 3 2 + 2 2 + 2Minimum output % 33 33 33 25 25Maximum total air flow l/s 6940 6936 7370 10026 10556Part Number 7490512 7490513 7490514 7490515 7490516Price (chiller only)**** £ 17,249 18,696 21,150 23,557 26,897

Part Number with AquaPack† 7490512-AP 7490513-AP 7490514-AP 7490515-AP 7490516-APPrice (chiller with AquaPack) £ 23,315 24,762 27,215 29,691 33,031* Cooling mode conditions: water inlet/outlet temperature12°C/7°C, ambient 35°C.** In dB ref = 10-12 W, ‘A’ weighted. Measured in accordance with ISO 9614-1.*** In dB ref 20 uPa, ‘A’ weighted. For information, calculated from the sound power level Lw(A). Declared dual number noise emission values in accordance with ISO 4871 (with an associated uncertainty of ±3 dB(A). Values are guidelines only.

Refer to the unit name plate.**** Standard commissioning not included. Standard day’s commissionin will be charged at £620 per day. Terms apply.† AquaPack includes: hydronic module116r, expansion tank 293, water buffer tank module 307, exchanger water filter 310A).

Extended Warranty Available

Page 28: Price List 2017 - CIAT

28

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AQUACIAT chiller model LD0150A LD0180A LD0200A LD0240A LD0260A LD0300AAccessories - factory fitted Part

NumberTotal price,

£Total price,

£Total price,

£Total price,

£Total price,

£Total price,

£Extra fan (180 to 240 mmCE available)* 12_1 1,001 1,001 1,001 1,001 1,001 1,001Extra low noise (1 to 6 dB(A) depending on model)* 15LS_1 437 437 437 437 437 437Protection grille for condenser coil 23 77 77 77 116 116 116Soft Start 25 750 750 750 750 750 750All year -20°C operation* 28_1 931 931 931 931 931 931Water exchanger frost protection* 42 488 488 488 488 488 488Exchanger and hydraulic frost protection 42B 669 669 669 669 669 669Master/slave operation 58 69 69 69 69 69 69Hydraulic module (fixed-speed single pump) HP 116R 869 869 869 869 869 869Hydraulic module (fixed-speed dual pump) HP 116S 1,829 1,829 1,829 1,829 1,829 1,829Hydraulic module (fixed-speed single pump) LP 116T 631 631 631 631 631 631Hydraulic module (fixed-speed dual pump) LP 116U 1,330 1,330 1,330 1,330 1,330 1,330Hydraulic module (variable-speed single pump) HP 116V 1,620 1,620 1,620 1,620 1,620 1,620Hydraulic module (variable-speed dual pump) HP 116W 2,521 2,521 2,521 2,521 2,521 2,521BACnet over IP 149 285 285 285 285 285 285MCHE anti-corrosion protect 2 (light corrosion) 262_1 437 437 437 689 689 689MCHE anti-corrosion protect 4 (harsh corrosion) 263_1 804 804 804 1,137 1,137 1,137Reinforced ECM filtration for pump VFD 282B 112 112 112 112 112 112Expansion tank 293 208 208 208 208 208 208Water buffer tank module 307 3,752 3,752 3,752 3,752 3,752 3,752Exchanger flexible sleeve connections 309A 403 403 403 403 403 403Exchanger water filter 310A 247 247 247 247 247 247Set point adjustment by 4-20 mA signal 311 53 53 53 53 53 53Free cooling dry management for Opera or Vextra 313 53 53 53 53 53 53

AQUACIAT chiller model LD0360A LD0390A LD0450A LD0520A LD0600AAccessories - factory fitted Part

NumberTotal price,

£Total price,

£Total price,

£Total price,

£Total price,

£Extra fan (180 to 240 mmCE available)* 12_1 1,884 1,884 1,884 1,884 1,884Extra low noise (1 to 6 dB(A) depending on model)* 15LS_1 668 683 683 905 905Protection grille for condenser coil 23 138 138 152 152 233Soft Start 25 1,102 1,102 1,102 1,470 1,470All year -20°C operation* 28_1 1,601 1,601 1,601 1,521 1,521Water exchanger frost protection* 42 579 579 579 579 579Exchanger and hydraulic frost protection 42B 688 688 688 688 688Master/slave operation 58 69 69 69 69 69Hydraulic module (fixed-speed single pump) HP 116R 874 874 874 943 943Hydraulic module (fixed-speed dual pump) HP 116S 1,792 1,792 1,943 1,943 1,943Hydraulic module (fixed-speed single pump) LP 116T 640 774 774 869 869Hydraulic module (fixed-speed dual pump) LP 116U 1,295 1,572 1,572 1,790 1,790Hydraulic module (variable-speed single pump) HP 116V 1,622 1,622 1,794 1,794 1,794Hydraulic module (variable-speed dual pump) HP 116W 2,483 2,483 2,748 2,748 2,748BACnet over IP 149 285 285 285 285 285MCHE anti-corrosion protect 2 (light corrosion) 262_1 847 847 876 876 1,378MCHE anti-corrosion protect 4 (harsh corrosion) 263_1 1,316 1,316 1,607 1,607 2,273Reinforced ECM filtration for pump VFD 282B 112 112 112 112 112Expansion tank 293 286 286 286 286 286Water buffer tank module 307 4,550 4,550 4,550 4,550 4,550Exchanger flexible sleeve connections 309A 403 403 403 403 403Exchanger water filter 310A 353 353 353 353 353Set point adjustment by 4-20 mA signal 311 53 53 53 53 53Free cooling dry management for Opera or Vextra 313 53 53 53 53 53* Not available with some options.

1 to 2 systems, total price, £ 3 to 4 systems, total price, £Service & maintenance, Year 1 1,875 3,750 Service & maintenance, Years 1 & 2 3,844 7,688 Service & maintenance, Years 1, 2 & 3 5,911 11,822

Service & maintenance based on 3 x visits per annum

AQUACIAT cooling only accessories

This is a compact and lightweight range of energy-efficient chillers covering from 40 kW to 160 kW which uses the MCHE aluminium coil and EEV as standard, with direct start scroll compressors, EC fans, safety pressure relief valve, sight glass, head pressure control, crankcase heaters, anti-short cycling, low water temperature and low water flow protection.

Listed below are all of the available options that can be purchased and factory fitted.

Page 29: Price List 2017 - CIAT

29

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIAT liquid chiller performance tableCooling capacitiesAQUACIAT chiller

Leaving water temp., °C

Outdoor air temperature, °C25 26 27 28 29 30 31 32 33 34 35

LD0150A

5/11 41 40.5 40 39.7 39.4 39 38.8 38.5 38.2 37.8 37.56/12 42 41.8 41.5 41.2 40.9 40.5 40.3 40 39.4 39.1 38.57/13 43.5 43.0 42.5 42.2 41.9 41.5 41.3 41 40.7 40.3 408/14 44.5 44.3 44 43.7 43.3 43 42.5 42 41.7 41.3 41

LD0180A

5/11 46 45.5 45 44.7 44.3 44 43.5 43 42.7 42.3 426/12 47 46.8 46.5 46.2 45.8 45.5 45.0 44.5 44.0 43.5 437/13 48.5 48.0 47.5 47.2 46.9 46.5 46.3 46 45.2 44.8 448/14 50 49.5 49 48.7 48.3 48 47.5 47 46.5 46.0 45.5

LD0200A

5/11 54 53.5 53 52.5 51.9 51.5 50.8 50 49.2 48.8 486/12 56 55.5 55 54.3 53.8 53 52.5 52 51.3 50.7 507/13 57.5 57.0 56.5 55.8 55.3 54.5 54.0 53.5 52.8 52.2 51.58/14 59.5 58.8 58 57.5 56.9 56.5 55.8 55 54.3 53.7 53

LD0240A

5/11 61.5 60.8 60 59.8 59.0 59 58.0 57 56.3 55.7 556/12 63.5 63.0 62.5 61.8 61.1 60.5 59.8 59 58.0 57.5 56.57/13 65.7 65.1 64.5 63.8 63.1 62.5 61.8 61 60.1 59.5 58.58/14 67.5 67.0 66.5 65.8 65.1 64.5 63.8 63 62.1 61.4 60.5

LD0260A

5/11 72 71.5 71 70.1 69.4 68.5 67.8 67 65.8 65.2 646/12 74 73.3 72.5 71.6 70.9 70 69.3 68.5 67.6 66.9 667/13 76 75.3 74.5 73.6 72.8 72 71.0 70 69.1 68.4 67.58/14 77.5 77.0 76.5 75.6 74.8 74 73.0 72 70.9 70.1 69

LD0300A

5/11 84 83.0 82 81.4 80.5 80 79.0 78 77.4 76.6 766/12 86 85.0 84 83.4 82.5 82 81.0 80 79.1 78.4 77.57/13 87.5 86.8 86 85.2 84.3 83.5 82.5 81.5 80.7 79.9 798/14 89.5 88.8 88 87.1 86.2 85.4 84.5 83.5 82.7 81.8 81

LD0360A

5/11 91 90.3 89.5 88.7 87.9 87 86.3 85.5 84.2 83.3 826/12 94 93.0 92 91.5 90.5 90 89.0 88 86.7 85.8 84.57/13 96.5 95.8 95 94.2 93.3 92.5 91.5 90.5 85.2 84.3 798/14 99 98.3 97.5 96.7 95.8 95 94.0 93 91.7 90.8 89.5

LD0390A

5/11 103 102.0 101 100.0 99.0 98 97.0 96 94.5 93.5 926/12 106 105.0 104 103.0 101.9 101 99.8 98.5 97.2 96.3 957/13 109 108.0 107 105.8 104.6 103.5 102.3 101 99.7 98.8 97.58/14 112 111.0 110 108.8 107.6 106.5 105.3 104 102.5 101.5 100

LD0450A

5/11 122 120.5 119 117.6 116.5 115 114.0 113 111.1 110.0 1086/12 125 124.0 123 121.4 120.1 118.5 117.3 116 114.3 113.2 111.57/13 129 127.5 126 124.6 123.3 122 120.5 119 117.3 116.2 114.58/14 132.5 131.0 129.5 128.1 126.8 125.5 124.0 122.5 120.6 119.4 117.5

LD0520A

5/11 143 141.8 140.5 138.9 137.5 136 134.5 133 130.9 129.6 127.56/12 147.5 146.0 144.5 143.0 141.4 140 138.3 136.5 134.4 133.1 1317/13 151.5 150.0 148.5 147.0 145.3 144 142.0 140 138.2 136.8 1358/14 155.5 154.0 152.5 151.0 149.4 148 146.3 144.5 142.2 140.8 138.5

LD0600A

5/11 165 163.5 162 160.3 158.8 157 155.5 154 152.0 150.5 148.56/12 168.5 167.0 165.5 163.8 162.3 160.5 159.0 157.5 155.5 154.0 1527/13 172.5 171.0 169.5 167.8 166.1 164.5 162.8 161 159.0 157.5 155.58/14 176.5 175.0 173.5 171.9 170.0 168.5 166.5 164.5 162.6 160.9 159

Page 30: Price List 2017 - CIAT

30

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AQUACIATAir-cooled heat pumps

• Screwed connection sleeves as standard.• Anti-vibration mounts as standard.• Brazed heat exchanger to offer high efficiency

and reduced refrigerant.• Connect touch controller.• Ice prevention frame coil heater.

AQUACIAT heat pump model ILD0150A ILD0180A ILD0200A ILD0240A ILD0260A ILD0300ANominal cooling capacity* kW 38 43 50 59 64 74EER/ESEER kW/kW 2.84/3.80 2.70/3.77 2.65/3.81 2.77/3.61 2.70/3.61 2.58/3.57Eurovent class C1 C C D C C DNominal heating capacity** kW 42 47 53 61 70 78COP/SCOP kW/kW 3.08/3.07 3.05/3.10 3.03/3.21 3.03/3.07 3.06/3.10 2.87/2.96Eurovent class H1 B B B B B CSound power***/Sound pressure at 10 m**** dB(A) 80/49 81/49 81/49 86/55 87/55 87/55Sound power extra low noise option*** dB(A) 79 80 80 80 80 80Sound pressure at 10 m extra low noise option† dB(A) 48 48 48 48 48 48Width x length mm 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)Weight - standard unit kg 497 506 543 549 559 564Compressors Scroll 2 2 2 2 2 2Minimum output % 50 50 50 50 50 50Maximum total air flow l/s 3692 3690 3910 5285 5284 5282Part Number (heat pump only) 7490822 7490823 7490824 7490825 7490826 7490827Total price (heat pump only)† £ 11,327 11,886 12,679 14,660 15,747 17,502

Part Number (heat pump with AquaPack)‡ 7490822-AP 7490823-AP 7490824-AP 7490825-AP 7490826-AP 7490827-APTotal price (heat pump with AquaPack) £ 16,403 16,962 17,754 19,736 20,822 23,426

AQUACIAT heat pump model ILD0302A ILD0360A ILD0390A ILD0450A ILD0520A ILD0600ANominal cooling capacity* kW 78 86 96 113 132 149EER/ESEER kW/kW 2.79/3.84 2.70/3.77 2.7/3.88 2.69/4.04 2.77/3.75 2.58/3.67Eurovent class C1 C C C D C DNominal heating capacity** kW 80 93 101 117 138 158COP/SCOP kW/kW 3.08/3.14 3.02/3.17 3.09/3.23 3.06/3.23 3.07/3.14 2.97/3.13Eurovent class H1 B B B B B CSound power***/Sound pressure at 10 m**** dB(A) 84/52 84/52 84/52 84/52 90/58 90/58Sound power extra low noise option*** dB(A) 83 83 83 83 83 83Sound pressure at 10 m extra low noise option**** dB(A) 52 51 51 51 51 51Width x length mm 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)Weight - standard unit kg 777 896 905 979 1053 1057Compressors Scroll 3 3 3 3 2 + 2 2 + 2Minimum output % 33 33 33 33 25 25Maximum total air flow l/s 7770 7380 7376 7818 10568 10568Part Number (heat pump only) 7491009 7490828 7490829 7490830 7490831 7490832Total price (heat pump only)† £ 18,350 20,082 21,891 24,876 28,058 31,583

Part Number (heat pump with AquaPack)‡ 7491009-AP 7490828-AP 7490829-AP 7490830-AP 7490831-AP 7490832-APTotal price (heat pump with AquaPack) £ 24,416 26,148 27,957 30,842 34,193 37,717* Cooling mode conditions: water inlet/outlet temperature 12°C/7°C, ambient 35°C.** Heating mode conditions: water inlet/outlet temperature 30°C/35°C, ambient 7°C/6°C.*** In dB ref = 10-12 W, ‘A’ weighted. Measured in accordance with ISO 9614-1.**** In dB ref 20 uPa, ‘A’ weighted. For information, calculated from the sound power level Lw(A). Declared dual number noise emission values in

accordance with ISO 4871 (with an associated uncertainty of ±3 dB(A). Values are guidelines only. Refer to the unit name plate.† Standard commissioning not included. Standard day’s commissionin will be charged at £620 per day. Terms apply.‡ AquaPack includes: hydronic module116r, expansion tank 293, water buffer tank module 307, exchanger water filter 310A).

Extended Warranty Available

Page 31: Price List 2017 - CIAT

31

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIAT heat pump model ILD0150A ILD0180A ILD0200A ILD0240A ILD0260A ILD0300AAccessories - factory fitted Part

NumberTotal price,

£Total price,

£Total price,

£Total price,

£Total price,

£Total price,

£Pre-treatment corrosion protection 3A 156 156 156 156 156 156Medium brine application 5B 1,065 1,065 1,065 1,065 1,065 1,065Low brine application 6B 1,819 1,819 1,819 1,819 1,819 1,819Extra fan (180 to 240 mmCE available)* 12_1 1,001 1,001 1,001 1,001 1,001 1,001Extra low noise (1 to 6 dB(A) depending on model)* 15LS_1 437 437 437 437 437 437Soft Start 25 750 750 750 750 750 750All year -20°C operation* 28_1 931 931 931 931 931 931Water exchanger frost protection* 42 488 488 488 488 488 488Exchanger and hydraulic frost protection 42B 669 669 669 669 669 669Master/slave operation 58 69 69 69 69 69 69Hydraulic module (fixed-speed single pump) HP 116R 869 869 869 869 869 869Hydraulic module (fixed-speed dual pump) HP 116S 1,829 1,829 1,829 1,829 1,829 1,829Hydraulic module (fixed-speed single pump) LP 116T 631 631 631 631 631 631Hydraulic module (fixed-speed dual pump) LP 116U 1,330 1,330 1,330 1,330 1,330 1,330Hydraulic module (variable-speed single pump) HP 116V 1,620 1,620 1,620 1,620 1,620 1,620Hydraulic module (variable-speed dual pump) HP 116W 2,521 2,521 2,521 2,521 2,521 2,521BACnet over IP 149 285 285 285 285 285 285External boiler management 156A 53 53 53 53 53 53Electric heater management 156B 53 53 53 53 53 53Reinforced ECM filtration for fan VFD 282A 126 126 126 126 126 126Reinforced ECM filtration for pump VFD 282B 112 112 112 112 112 112Expansion tank 293 208 208 208 208 208 208Water buffer tank module 307 3,752 3,752 3,752 3,752 3,752 3,752Exchanger flexible sleeve connections 309A 403 403 403 403 403 403Exchanger water filter 310A 247 247 247 247 247 247Set point adjustment by 4-20 mA signal 311 53 53 53 53 53 53

AQUACIAT heat pump model ILD0302A ILD0360A ILD0390A ILD0450A ILD0520A ILD0600AAccessories - factory fitted Part

NumberTotal price,

£Total price,

£Total price,

£Total price,

£Total price,

£Total price,

£Pre-treatment corrosion protection 3A 190 317 317 485 485 485Medium brine application 5B 1,770 1,770 1,770 1,770 1,770 1,770Low brine application 6B 2,729 2,729 2,729 2,729 3,120 3,120Extra fan (180 to 240 mmCE available)* 12_1 1,001 1,884 1,884 1,884 1,884 1,884Extra low noise (1 to 6 dB(A) depending on model)* 15LS_1 518 668 683 683 905 905Soft Start 25 750 1,102 1,102 1,102 1,470 1,470All year -20°C operation* 28_1 1,514 1,601 1,601 1,601 1,521 1,521Water exchanger frost protection* 42 579 579 579 579 579 579Exchanger and hydraulic frost protection 42B 669 688 688 688 688 688Master/slave operation 58 87 69 69 69 69 69Hydraulic module (fixed-speed single pump) HP 116R 874 874 874 874 943 943Hydraulic module (fixed-speed dual pump) HP 116S 1,792 1,792 1,792 1,943 1,943 1,943Hydraulic module (fixed-speed single pump) LP 116T 640 640 774 774 869 869Hydraulic module (fixed-speed dual pump) LP 116U 1,295 1,295 1,572 1,572 1,790 1,790Hydraulic module (variable-speed single pump) HP 116V 1,622 1,622 1,622 1,794 1,794 1,794Hydraulic module (variable-speed dual pump) HP 116W 2,483 2,483 2,483 2,748 2,748 2,748BACnet over IP 149 285 285 285 285 285 285External boiler management 156A 53 53 53 53 53 53Electric heater management 156B 53 53 53 53 53 53Reinforced ECM filtration for fan VFD 282A 250 250 250 250 250 250Reinforced ECM filtration for pump VFD 282B 112 112 112 112 112 112Expansion tank 293 286 286 286 286 286 286Water buffer tank module 307 4,550 4,550 4,550 4,550 4,550 4,550Exchanger flexible sleeve connections 309A 403 403 403 403 403 403Exchanger water filter 310A 353 353 353 353 353 353Set point adjustment by 4-20 mA signal 311 53 53 53 53 53 53* Not available with some options.

1 to 2 systems, total price, £ 3 to 4 systems, total price, £Service & maintenance, Year 1 1,875 3,750 Service & maintenance, Years 1 & 2 3,844 7,688 Service & maintenance, Years 1, 2 & 3 5,911 11,822

Service & maintenance based on 3 x visits per annum

AQUACIAT heat pump accessories

This is a compact and lightweight range of heat pumps covering from 42 kW to 158 kW which uses round tube and plate fin coils and EEV as standard, with direct start scroll compressors, safety pressure relief valve, sight glass, head pressure control, crankcase heaters, anti-short cycling, low water temperature and low water flow protection, as well as protection grille for condensing coil as standard.

Listed below are all of the available options that can be purchased and factory fitted.

Page 32: Price List 2017 - CIAT

32

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AQUACIAT heat pump performance tablesCooling capacitiesAQUACIAT heat pump

Leaving water temp., °C

Outdoor air temperature, °C25 26 27 28 29 30 31 32 33 34 35

ILD0150A

5/11 39.0 38.5 38.0 37.7 37.4 37.0 36.8 36.5 36.2 35.8 35.56/12 40.0 39.8 39.5 39.2 38.9 38.5 38.3 38.0 37.4 37.1 36.57/13 41.5 41.0 40.5 40.2 39.9 39.5 39.3 39.0 38.7 38.3 38.08/14 42.5 42.3 42.0 41.7 41.3 41.0 40.5 40.0 39.7 39.3 39.0

ILD0180A

5/11 45 44.5 44 43.7 43.3 43 42.5 42 41.7 41.3 416/12 46 45.8 45.5 45.2 44.8 44.5 44.0 43.5 43.0 42.5 427/13 47.5 47.0 46.5 46.2 45.9 45.5 45.3 45 44.2 43.8 438/14 49 48.5 48 47.7 47.3 47 46.5 46 45.5 45.0 44.5

ILD0200A

5/11 53 52.5 52 51.5 50.9 50.5 49.8 49 48.2 47.8 476/12 54.5 54.0 53.5 53.0 52.5 52 51.5 51 50.3 49.8 497/13 56 55.5 55 54.3 53.9 53 52.8 52.5 51.8 51.2 50.58/14 58 57.3 56.5 56.0 55.4 55 54.3 53.5 53.0 52.5 52

ILD0240A

5/11 60 59.3 58.5 58.3 57.5 57.5 56.5 55.5 54.8 54.2 53.56/12 62 61.5 61 60.3 59.6 59 58.3 57.5 56.5 56.0 557/13 64 63.5 63 62.3 61.6 61 60.3 59.5 59.5 59.0 598/14 66 65.5 65 64.3 63.6 63 62.3 61.5 60.6 60.0 59

ILD0260A

5/11 67 66.5 66 65.3 64.5 64 63.0 62 61.3 60.7 606/12 69 68.5 68 67.3 66.6 66 65.3 64.5 63.6 62.9 627/13 71 70.5 70 69.3 68.6 68 67.3 66.5 65.6 64.9 648/14 73 72.5 72 71.4 70.5 70 69.0 68 67.3 66.7 66

ILD0300A

5/11 80 79.3 78.5 77.9 77.0 76.5 75.5 74.5 73.9 73.1 72.56/12 82 81.0 80 79.6 78.8 78.5 77.5 76.5 75.6 74.9 747/13 83.5 82.8 82 81.2 80.4 79.5 78.8 78 77.1 76.4 75.58/14 85.5 84.8 84 83.2 82.3 81.5 80.5 79.5 78.9 78.1 77.5

ILD0302A

5/11 83 82.0 81 80.4 79.5 79 78.0 77 76.4 75.6 756/12 85 84.0 83 82.4 81.5 81 80.0 79 78.1 77.4 76.57/13 86.5 85.8 85 84.2 83.3 82.5 81.5 80.5 79.6 78.9 788/14 88.5 87.8 87 86.2 85.3 84.5 83.5 82.5 81.7 80.8 80

ILD0360A

5/11 90 89.3 88.5 87.7 86.9 86 85.3 84.5 83.2 82.3 816/12 93 92.0 91 90.5 89.5 89 88.0 87 85.7 84.8 83.57/13 95.5 94.8 94 93.2 92.3 91.5 90.5 89.5 88.2 87.3 868/14 98 97.3 96.5 95.7 94.8 94 93.0 92 90.7 89.8 88.5

ILD0390A

5/11 102 101.0 100 99.0 98.0 97 96.0 95 93.5 92.5 916/12 105 104.0 103 102.0 100.9 100 98.8 97.5 96.2 95.3 947/13 108 107.0 106 104.8 103.6 102.5 101.3 100 98.7 97.8 96.58/14 111 110.0 109 108.3 106.9 106.5 104.8 103 101.5 100.5 99

ILD0450A

5/11 120.5 119.0 117.5 116.0 114.7 113.5 109.3 112 110.1 109.0 1076/12 123.5 122.5 121.5 120.0 114.5 117 110.5 114.5 113.1 111.9 110.57/13 127.5 126.0 124.5 123.2 122.0 121 112.0 117.5 115.8 114.7 1138/14 131 129.5 128 124.4 120.9 124.5 122.8 121 119.7 118.4 117

ILD0520A

5/11 138.5 138.0 137.5 136.9 135.5 136 132.0 130 128.1 126.3 124.56/12 143 141.8 140.5 139.2 138.0 136.5 138.3 136.5 131.6 130.0 128.27/13 147.5 146.0 144.5 143.0 141.5 140 138.8 137.5 136.0 134.3 1328/14 152.5 151.0 149.5 148.0 146.5 145 146.3 141.5 140.8 139.0 136.2

ILD0600A

5/11 157.5 156.0 154.5 153.0 151.5 150 148.5 147 145.2 143.8 1426/12 161 160.5 159 157.5 156.0 154.5 153.0 151.5 149.5 148.0 1467/13 168 166.2 164.5 162.3 160.7 159 155.5 154 152.7 151.4 1508/14 173 171.0 169.5 167.5 165.8 164 162.0 160 158.1 156.3 154.5

Page 33: Price List 2017 - CIAT

33

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIAT heat pump performance tablesHeating capacitiesAQUACIAT heat pump

Outdoor air temp., °C

Leaving water temperature, °C30/35°C 40/45°C 45/50°C

Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW

ILD0150A

-5 32 24 32 23 32 23-4 32.75 25.25 32.75 24 32.75 24-3 33.5 26.5 33.5 25 33.5 25-2 34.6 28.6 34.3 27.1 34.3 26.9-1 35.1 29.0 34.8 27.5 34.8 27.30 36 31 35.5 29.5 35.5 291 37 32.75 36.5 31 36.25 30.52 38 34.5 37.5 32.5 37 323 39.1 37.1 38.6 35.6 38.1 35.14 39.6 37.6 39.1 36.1 38.6 35.65 40.5 40 40 39 39.5 38.56 41.75 41.6 41 41 40.5 407 43 43 42 42 41.5 41.5

ILD0180A

-5 35 27 35.5 25.5 35 25-4 36 28 36.25 26.75 35.75 26-3 37 29 37 28 36.5 27-2 38.1 31.6 38.3 30.3 37.6 29.4-1 38.6 32.1 38.9 30.8 38.1 29.80 39.5 34.5 40 33 39 321 40.5 36.25 40.75 34.75 40 33.752 41.5 38 41.5 36.5 41 35.53 42.8 40.8 42.8 39.8 42.0 39.14 43.4 41.4 43.4 40.4 42.7 39.65 44.5 44 44.5 43.5 43.5 436 45.75 45.7 45.75 45.25 44.75 44.57 47 47 47 47 46 46

ILD0200A

-5 40.5 31 40 29 40 28.5-4 41.5 32.25 41 30.25 41 29.75-3 42.5 33.5 42 31.5 42 31-2 44.0 35.5 43.5 34.3 43.3 33.8-1 44.7 36.9 44.2 34.8 43.9 34.30 46 39.5 45.5 37.5 45 371 47 41.75 46.5 39.5 46 38.752 48 44 47.5 41.5 47 40.53 49.8 47.3 49.0 45.5 48.5 44.54 50.5 48.0 49.7 46.2 49.2 45.25 52 51 51 50 50.5 496 53.5 53 52 51.5 51.5 50.757 55 55 53 53 52.5 52.5

ILD0240A

-5 46.5 37 45.5 35.5 44.5 33.5-4 47.75 38.5 46.75 36.25 45.75 34.75-3 49 40 48 37 47 36-2 50.7 42.8 49.8 39.8 48.5 37.8-1 51.5 43.4 50.5 40.4 49.2 39.10 53 46 52 43 50.5 41.51 54.25 48 53.25 44.75 51.75 43.252 55.5 50 54.5 46.5 53 453 57.5 54.2 56.2 51.5 54.7 50.04 58.3 55.1 57.1 52.3 55.6 50.85 60 59 58.5 57 57 55.56 61.5 61 59.75 59 58.5 57.757 63 63 61 61 60 60

Page 34: Price List 2017 - CIAT

34

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AQUACIAT heat pump performance tablesHeating capacities (continued)AQUACIAT heat pump

Outdoor air temp., °C

Leaving water temperature, °C30/35°C 40/45°C 45/50°C

Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW

ILD0260A

-5 53 42 52.5 40 52 39-4 54.25 42.9 53.75 41 53.25 40.25-3 55.5 45 55 42 54.5 41.5-2 57.5 48.0 56.0 44.0 56.2 44.0-1 58.3 48.7 53.5 45.7 57.1 44.70 60 51.5 59 48.5 58.5 471 60.5 53.75 60.5 50.5 59.75 49.252 61 56 62 52.5 61 51.53 64.2 61.2 63.9 58.5 62.7 57.24 66.0 63.0 64.9 59.3 63.6 58.15 68 67 66.5 65 65 63.56 69.5 69 67.9 67.5 66.75 667 71 71 70 70 68.5 68.5

ILD0300A

-5 59 47 58.5 44.5 58.5 44-4 60.5 48.75 60 46 59.75 45.5-3 62 50.5 61.5 47.5 61 47-2 64.2 54.0 63.4 50.7 62.9 50.0-1 65.2 55.4 64.4 51.5 63.9 51.20 67 58 66 54.5 65.5 53.51 68.75 60.5 67.5 56.75 67 55.752 70.5 63 69 59 68.5 583 72.9 66.9 71.1 65.4 70.4 64.24 74.0 69.4 72.2 66.4 71.5 65.25 76 74.5 74 72.5 73 716 78 77.25 75.5 75.5 74.75 73.757 80 80 78 78 76.5 76.5

ILD0302A

-5 60.5 48 59.5 45 59 44-4 62.25 49.75 61 46.5 60.5 45.5-3 64 51.5 62.5 48 62 47-2 66.2 55.0 64.7 51.2 63.9 50.0-1 67.2 55.8 65.7 52.0 64.9 50.80 69 59 67.5 55 66.5 53.51 70.75 61.75 69 57.25 68 55.752 72.5 64.5 70.5 59.5 69.5 583 75.1 70.4 72.9 64.3 71.6 64.94 76.3 71.5 74.0 69.0 72.7 65.95 78.5 77 76 74 74.5 72.56 80.4 80.4 72.2 64.3 76.0 76.07 83 83 80 80 78 78

ILD0360A

-5 70.5 55.5 69 52 67.5 50.5-4 72 57 78 77 69.4 51.6-3 74 60 72.5 55.5 71 54-2 76.6 63.9 74.4 58.0 73.6 57.7-1 77.8 64.9 76.3 60.4 74.7 58.60 80 68.5 78.5 64 77 621 81.9 71.3 74.4 57.9 78.6 64.62 84 74.5 82 69.5 80.5 67.53 86.0 79.0 84.8 77.4 83.1 75.44 88.1 82.3 86.1 78.5 84.3 76.55 90.5 88.5 88.5 86 86.5 846 92.6 92.6 92.6 90.5 88.4 88.47 95 95 93 93 90.5 90.5

Page 35: Price List 2017 - CIAT

35

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

AQUACIAT heat pump performance tablesHeating capacities (continued) AQUACIAT heat pump

Outdoor air temp., °C

Leaving water temperature, °C30/35°C 40/45°C 45/50°C

Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW Instantaneous, kW Integrated, kW

ILD0390A

-5 77 61 76 57.5 76 56.5-4 78.7 62.3 78.1 58.7 77.5 57-3 80.5 65 80 61.5 79.5 60-2 83.3 69.4 82.6 65.4 81.8 62.9-1 84.6 70.5 83.8 66.4 83.1 64.90 87 74.5 86 70 85 68.51 89.0 77.5 87.8 72.9 86.8 71.42 91 81 90 76 88.8 74.53 93.4 85.8 92.5 84.6 90.0 83.14 95.5 89.6 93.9 85.9 92.8 86.05 98 96.5 96 94 95 92.56 100.5 100.5 98.5 98.5 97.0 97.07 103 103 101 101 99 99

ILD0450A

-5 89 71 88 66 87.5 65-4 91.3 72.2 90 67.4 89.4 66.4-3 93.5 75 92 70 91.5 69-2 97.0 79.6 95.0 74.1 94.3 72.9-1 98.5 81.5 96.5 75.3 95.7 74.00 101.5 85 99 79 98 77.51 104.0 88.0 101.3 82.0 100.0 80.22 106.5 92 103.5 85 102.5 833 110.2 101.7 107.0 96.0 105.5 94.04 111.9 105.0 108.6 97.5 107.1 98.05 115 112.5 111.5 108 109.5 1066 117.7 117.7 114.0 114.0 112.0 112.07 121 121 117 117 114.5 114.5

ILD0520A

-5 105 84 104 79 103 77.5-4 107.5 85 106.4 80 105.6 78.4-3 110 89 109 83.5 108 82-2 113.9 95.0 111.5 87.5 111.2 87.3-1 115.7 97.4 114.0 91.5 112.9 88.60 119 102 117 95.6 115.5 93.51 121.8 106.4 120.0 100.0 110.4 97.62 125 111 122.5 104 121 1023 129.1 120.9 126.4 115.4 124.4 113.44 131.1 122.7 128.3 117.2 126.3 115.25 134.5 132 131.5 128 129 1266 137.0 137.0 134.5 134.5 132.0 132.07 141 141 138 138 135.5 135.5

ILD0600A

-5 120 96 119.5 90.5 119 89.5-4 123 98 122 92.7 122 91.8-3 126.5 105 125 97 125 96-2 130.8 110.9 129.1 101.5 128.6 102.0-1 132.8 112.6 131.1 105.1 130.6 103.50 136.5 118 134.5 111 133.5 1091 139.8 123.0 137.0 115.5 136.4 113.72 143.5 128.5 140.5 120.5 139.5 118.53 147.0 136.0 144.0 129.0 143.5 131.34 150.5 141.7 147.2 138.0 145.7 136.05 154.5 152 151 147.5 149 145.56 158.0 158.0 154.0 154.0 152.0 152.07 162 162 158 158 155.5 155.5

Page 36: Price List 2017 - CIAT

36

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

COADIS LINE 600Cassette fan coil unit

• Suction/discharge through 180° or 360° FLEXIWAY grille.• Installation in reduced ceilings with modern styling.• Air supply with Coanda effect for guaranteed comfort.• Epure filter for excellent air quality.• Manufactured according to eco-concept, 87% recyclable.• Quiet, standard or energy-efficient HEE motor.

For cooling or heating (2-pipe)Unit Cooling Heating Part Number Total price, £Coadis Line Motor W W 2-pipe612 Standard 2040 2980 7401354 591622 Standard 2600 3610 7401355 626632 Standard 4290 5500 7401356 687612 HEE 2040 2980 7401351 712622 HEE 2600 3610 7401352 743632 HEE 4290 5500 7401353 802

For cooling or heating (4-pipe)Unit Cooling Heating Part Number Total price, £Coadis Line Motor W W 4-pipe624 Standard 2600 3660 7401359 653634 Standard 4290 3720 7401360 747624 HEE 2600 3660 7401357 966634 HEE 4290 3720 7401358 867

Select from 1-way or 4-way grilleDescription Part Number Total price, £180° suction/discharge grille with Epure filter 600 7350577 Included360° suction/discharge grille with Epure filter 600 7350575 Included

Available unit optionsDescription Part Number Total price, £Increased performance kit 7301625 724-way water control valve* (2-pipe) E037567 832-way water control valve* (2-pipe) E037605 702-piece 4-way water control valve* (4-pipe) E037583 1662-piece 2-way water control valve* (4-pipe) E037621 139Condensate pump* 7301623 105Wall-mounted thermostat RTR 7011/RTR 7203* 5201018/5201021 30/51Set of mounting rubbers (per unit)* Set = 4 x 0219453 6All units are supplied with an Epure air filter as standard. These Epure filters need to be replaced periodically. Replacement filters can be found at the back of this price list.* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request.

The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.

Page 37: Price List 2017 - CIAT

37

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

COADIS LINE 900Cassette fan coil unit

• Suction/discharge through 360° FLEXIWAY grille.• Installation in reduced ceilings with modern styling.• Air supply with Coanda effect for guaranteed comfort.• Epure filter for excellent air quality.• Manufactured according to eco-concept, 87% recyclable.• Quiet, standard or energy-efficient HEE motor.

For cooling or heating (2-pipe)Unit Cooling Heating Part Number Total price, £Coadis Line Motor W W 2-pipe922 Standard 6100 7730 7344009 1,040932 Standard 7640 9000 7344010 1,310922 HEE 6060 7770 7344015 1,129932 HEE 7600 9040 7344016 1,413932SP HEE 9350 11200 7351393 1,536

For cooling or heating (4-pipe)Unit Cooling Heating Part Number Total price, £Coadis Line Motor W W 4-pipe924 Standard 6100 4100 7344011 1,118934 Standard 7640 5070 7344012 1,418924 HEE 6060 4110 7344017 1,056934 HEE 7600 5090 7344018 1,521934SP HEE 9350 5720 7351394 1,653

4-way grilleDescription Part Number Total price, £360° suction/discharge grille with Epure filter 7335537 Included

Available unit optionsDescription Part Number Total price, £4-way water control valve* (2-pipe) E037575 992-way water control valve* (2-pipe) E037613 812-piece 4-way water control valve* (4-pipe) E037591 1822-piece 2-way water control valve* (4-pipe) E037648 150Condensate pump for 900 included 7301623 IncludedWall-mounted thermostat RTR 7011/RTR 7203* 5201018/5201021 30/51Set of mounting rubbers (per unit)* Set = 4 x 0219453 6All units are supplied with an Epure air filter as standard. These Epure filters need to be replaced periodically. Replacement filters can be found at the back of this price list.* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on

request.

The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.

Page 38: Price List 2017 - CIAT

38

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

COMFORT LINEDucted type fan coil

• Comfort unit for flexible installation.• Modular air supply configuration, through

expanded capabilities.• Especially low sound level.• Optional Epure filter for excellent air quality.• Optional HEE (high energy-efficiency) motor for

exceptional savings of up to 87%.• Equipped with flange on discharge frame.• Very easy unit maintenance.

For cooling or heating (2-pipe) with G3 filterUnit Cooling Heating Part Number Total price, £ Part Number Total price, £Comfort Line W W AC motor 2-pipe (model I AC) HEE Motor 2-pipe (model I HEE)12B 1540 2390 CFL-12B-AC-G3 332 CFL-12B-HEE-G3 44812D 1970 2770 CFL-12D-AC-G3 350 CFL-12D-HEE-G3 46512E 2360 3050 CFL-12E-AC-G3 361 CFL-12E- HEE -G3 47722C 3060 4550 CFL-22C-AC-G3 381 CFL-22C- HEE -G3 48522D 3510 4920 CFL-22D-AC-G3 394 CFL-22D- HEE -G3 49822E 3810 5150 CFL-22E-AC-G3 405 CFL-22E- HEE -G3 50932C HEE only 5000 7820 CFL-32C-AC-G3 451 CFL-32C- HEE -G3 56732D HEE only 5550 8490 CFL-32D-AC-G3 468 CFL-32D- HEE -G3 58532E HEE only 5780 8600 CFL-32E-AC-G3 476 CFL-32E- HEE -G3 59342C HEE only 5760 8220 CFL-42C-AC-G3 495 CFL-42C- HEE -G3 61042D HEE only 6630 8890 CFL-42D-AC-G3 513 CFL-42D- HEE -G3 62942E HEE only 7040 9130 CFL-42E-AC-G3 537 CFL-42E- HEE -G3 65352C HEE only 7570 10500 CFL-52C-AC-G3 582 CFL-52C- HEE -G3 68952D HEE only 8110 11200 CFL-52D-AC-G3 609 CFL-52D- HEE -G3 71752E HEE only 9350 12100 CFL-52E-AC-G3 651 CFL-52E- HEE -G3 75862B HEE only 11700 17000 CFL-62B-AC-G3 887 CFL-62B- HEE -G3 1,07562D HEE only 14400 19700 CFL-62D-AC-G3 988 CFL-62D- HEE -G3 1,17662E HEE only 16800 21900 CFL-62E-AC-G3 1,062 CFL-62E- HEE -G3 1,251

For cooling or heating (4-pipe) with G3 filterUnit Cooling Heating Part Number Total price, £ Part Number Total price, £Comfort Line W W AC motor 4-pipe (model I AC) HEE Motor 4-pipe (model I HEE)14B 1540 2730 CFL14B-AC-G3 364 CFL14B-HEE-G3 47914D 2000 3780 CFL14D-AC-G3 380 CFL14D- HEE-G3 49624C 3060 3440 CFL24C-AC-G3 409 CFL24C- HEE-G3 51324D 3600 4670 CFL24D-AC-G3 426 CFL24D- HEE-G3 53034C HEE only 4970 5670 CFL34C-AC-G3 482 CFL34C- HEE-G3 59934D HEE only 5680 7630 CFL34D-AC-G3 508 CFL34D- HEE-G3 65244C HEE only 5710 6230 CFL44C-AC-G3 534 CFL44C- HEE-G3 65044D HEE only 6680 6190 CFL44D-AC-G3 560 CFL44D- HEE-G3 67554C HEE only 7530 8160 CFL54C-AC-G3 629 CFL54C- HEE-G3 73654D HEE only 8350 8110 CFL54D-AC-G3 674 CFL54D- HEE-G3 78164B HEE only 12100 21300 CFL64B-AC-G3 1,029 CFL64B- HEE-G3 1,21764D HEE only 15400 21300 CFL64D-AC-G3 1,086 CFL64D- HEE-G3 1,274All units are supplied with a G3 air filter as standard.

Page 39: Price List 2017 - CIAT

39

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

Available unit optionsDescription Size 1 Size 2 Size 3 Size 4 Size 5 Size 6Surcharge for 200 mm supply air spigots (for model Y)

7344898£27

7344888£33

7344889£42

7344910£45

7344911£51

7380251£92

Surcharge for 200 mm supply and return air spigots (for model H)

7344898 + 7344936

£66

7344888 + 7344930

£78

7344889 + 7344931

£99

7344910 + 7344941£110

7344911 + 7344942£129

7380251 + 7380259£209

Epure filter £18 £28 £27 £33 £47 £66

Description Part Number Total price, £Wall-mounted thermostat RTR 7011/RTR 7203* 5201018/5201021 30/51Condensate pump* 7394451 118Set of mounting rubbers (per unit)* Set = 4 x 0219453 6

Available unit optionsDescription Total price, £ Total price, £ Total price, £ Total price, £ Total price, £ Total price, £2-pipe units Size 1 Size 2 Size 3 Size 4 Size 5 Size 64-way water control valve* E037567

83 83 83 - - -

4-way water control valve* E037575

- - - 99 99 99

2-way water control valve* E037605

70 70 70 - - -

2-way water control valve* E037613

- - - 81 81 81

4-pipe units Size 1 Size 2 Size 3 Size 4 Size 5 Size 62-piece 4-way water control valve* E037583

166 166 166 - - -

2-piece 4-way water control valve* E037591

- - - 182 182 182

2-piece 2-way water control valve* E0376210

139 139 139 - - -

2-piece 2-way water control valve* E037648

- - - 150 150 150

* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request. The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water

range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.

COMFORT LINEAvailable options

Page 40: Price List 2017 - CIAT

40

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

MAJOR LINE CV/CHCabinet unit

• For cooling and/or heating.• Available in 6 unit sizes.• Easy unit installation and maintenance.• One unit model for both vertical and horizontal usage.• Highly suitable for offices and hotel rooms.• HEE motor available as an option.

For cooling or heating (2-pipe)Unit Cooling Heating Part Number Total price, £Major Line W W102A 1410 4440 7243000 282102C 1800 4860 7243016 296202A 2370 7450 7243040 303202C 3070 8880 7243056 323202D 3360 9290 7243068 327302A 3530 12300 7243080 357302B 4280 12700 7243092 360302C 4910 14300 7243096 380402C 6480 19400 7243136 421502C 7650 21900 7243176 468602D 9970 27000 7243216 581

For cooling and heating (4-pipe)Unit Cooling Heating Part Number Total price, £Major Line W W 4-pipe104X 1800 1970 7243032 322204X 3070 3360 7243072 351304X 4910 5220 7243112 411404X 6480 7110 7243152 458504X 7650 8510 7243192 512604X 9030 10100 7243220 595All units are supplied with a G3 air filter as standard.

Available unit optionsDescription Part Number Total price, £Option for energy-efficient HEE brushless motor (per unit) - 120

Page 41: Price List 2017 - CIAT

41

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

MAJOR LINE NCV/NCHConcealed unit

• For cooling and/or heating.• Available in 6 unit sizes.• Easy unit installation and maintenance.• One unit model for both vertical and horizontal usage.• Highly suitable for offices and hotel rooms.• HEE motor available as an option.

For cooling or heating (2-pipe)Unit Cooling Heating Part Number Total price, £Major Line W W102A 1410 4440 7243250 225102C 1800 4860 7243266 240202A 2370 7450 7243290 243202C 3070 8880 7243306 262202D 3360 9290 7243318 267302A 3530 12300 7243330 291302B 4280 12700 7243342 294302C 4910 14300 7243346 313402C 6480 19400 7243386 349502C 7650 21900 7243426 386602D 9970 27000 7243466 492

For cooling and heating (4-pipe)Unit Cooling Heating Part Number Total price, £Major Line W W 4-pipe104X 1800 1970 7243282 265204X 3070 3360 7243322 291304X 4910 5220 7243362 345404X 6480 7110 7243402 385504X 7650 8510 7243442 430604X 9030 10100 7243470 506All units are supplied with a G3 air filter as standard.

Available unit optionsDescription Part Number Total price, £Option for energy-efficient HEE brushless motor (per unit) - 120

Page 42: Price List 2017 - CIAT

42

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

MAJOR LINECabinet and concealed unit optionsAvailable unit optionsDescription Total price, £ Total price, £ Total price, £ Total price, £ Total price, £ Total price, £2-pipe units 102 202 302 402 502 6024-way water control valve*E037567

83 83 83 83 - -

4-way water control valve*E037575

- - - - 99 99

2-way water control valve*E037605

70 70 70 70 - -

2-way water control valve*E037567

- - - - 81 81

4-pipe units 104 204 304 404 504 6042-piece 4-way water control valve*E037583

166 166 166 166 - -

2-piece 4-way water control valve*E037591

- - - - 182 182

2-piece 2-way water control valve*E037621

139 139 139 139 - -

2-piece 2-way water control valve*E037648

- - - - 150 150

All unit sizesDescription Part Number Total price, £Energy-efficient HEE brushless motor - 120Condensate pump* 7203415 140Wall-mounted thermostat RTR 7011/RTR 7203* 5201018/5201021 30/51Built-in thermostat V30 (vertical cabinet installation only) - 79Set of mounting rubbers (per unit)* Set = 4 x 0219453 6* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request. The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water

range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.

Page 43: Price List 2017 - CIAT

43

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

FLOWAY ACCESSAir handling unit

• Dual flow ‘plug and play’ air handling unit.• Double filtration (F7 and F9).• Rotary heat exchanger with constant speed.• Free cooling and night cooling management.• EC fan motor.• Casing mechanical strength = D2.• Air leakage (± pressure) = L2.• Air leakage filter assembly = F9.• Thermal transmittance = T3.• Thermal bridge = TB2.

Floway Access 1000 2000 3000 5000 5000 7500 7500Air flow m3/s 0.3 0.6 0.9 1.2 1.4 1.7 2.2Minimum air flow m3/s 0.083 0.139 0.194 0.250 0.250 0.389 0.389Maximum air flow m3/s 0.333 0.694 1.028 1.583 1.583 2.361 2.361V air filter section m/s 1.21 1.42 1.42 1.16 1.45 1.18 1.57Recovery efficiency EN308* % 79.0 79.0 78.7 81.0 78.3 81.6 78.2Width x height mm 810 x 958 1010 x 1158 1210 x 1359 1510 x 1659 1510 x 1659 1810 x 1959 1810 x 1959Length mm 1266 1310 1600 1600 1600 1600 1600Weight kg 201 309 432 604 604 751 751Supply power kW 1.43 2.5 3.82 4.23 4.23 6.03 6.03Supply Phase 1Ø 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + TFans (supply and extract) Polypropylene Aluminum Aluminum Aluminum AluminumPrice**** £ 6,227 8,143 10,697 12,613 12,613 15,008 15,008Price**** including electric heater (2-stage)

£ 7,169 9,229 11,903 13,906 13,906 16,517 16,517

Floway Access c/w hot water coil (1-row)Fan motor assembly supply W 258 542 819 892 1234 1162 1821Fan motor assembly exhaust W 230 478 726 819 1101 1064 1629Specific fan power kW/m3/s 1.626 1.700 1.716 1.487 1.668 1.310 1.568Heating water coil capacity** kW 4.0 7.9 11.9 15.2 18.5 22.5 29.1Price £ 6,866 8,861 11,576 13,619 13,619 16,246 16,246

Floway Access cooling and heating/cooling only coil (2-row)Fan motor assembly supply W 278 553 832 923 1256 1199 1851Fan motor assembly exhaust W 230 478 726 819 1101 1064 1629Specific fan power kW/m3s 1.694 1.719 1.731 1.514 1.684 1.331 1.582Changeover coil capacity (heating)** kW 4.0 7.9 11.9 15.2 18.5 22.5 29.1Changeover coil capacity (cooling)*** kW 5.7 11.4 17.1 21.9 26.6 32.3 41.8Price £ 7,065 9,037 11,775 13,811 13,811 16,469 16,469* ERP regulation UE 1253/2014.** Capacity at (W 45-40°C)*** Capacity at (W 7-12°C)**** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus

DX Option Available

On Request

Page 44: Price List 2017 - CIAT

44

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

AccessoriesFloway Access 1000 2000 3000 5000 7500DescriptionFilter - F9 HEE £ 77 115 132 232 271Set of aluminum fans (supply and exhaust) £ 1132 1456 1809 Inc IncEnergy meter with communication £ 843 1,155 1,155 1,155 1,155Actuator damper – indoor AHUDimensions

£ 128 168 343 375 415mm 250 diameter 355 diameter 1150 x 560 1450 x 650 1750 x 840

Actuator damper – outdoor AHUDimensions

£ 296 312 343 375 415mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1750 x 84

Flexible sleeve (intake OR discharge)Dimensions

£ 17 20 76 91 112mm 250 dia 355 dia 990 x 510 1290 x 610 1590 x 810

Roof £ 346 363 389 449 518Hood £ 184 200 228 256 287Separator screen for hood £ 28 44 80 96 119Adjustable feetQuantity

£ 64 96 128 128 1284 6 8 8 8

Multi-units display (1-30) (display + TCONN card) £ 160 160 160 160 160LON PCB £ 280 280 280 280 280KNX PCB £ 280 280 280 280 280Modbus TCP – BACnet IP PCB £ 359 359 359 359 359Webserver PCB £ 439 439 439 439 439IAQ sensor kit (CO2) £ 559 559 559 559 559Constant pressure management kit £ 203 203 203 203 203Ambient in-room control kit £ 184 184 184 184 184Smoke detector kit £ 319 319 319 319 319RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53

FLOWAY ACCESSAir handling unit accessories

Page 45: Price List 2017 - CIAT

45

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

FLOWAY CLASSICAir handling unit

Rotary heat exchanger

• Dual flow ‘plug and play’ air handling unit.• Double filtration (F7 and F9).• Rotary heat exchanger with variable speed.• Free cooling and night cooling management.• EC fan motor.• Electrical pre-heater available = -15°C heat recovery.• Casing mechanical strength = D2.• Air leakage (± pressure) = L2.• Air leakage filter assembly = F9.• Thermal transmittance = T3.• Thermal bridge = TB2.

Floway Classic 1000 2000 3000 4000 5000 6000 7500 10000 10000 15000 15000Air flow m3/s 0.30 0.55 0.90 1.15 1.35 1.70 2.20 2.80 3.10 3.80 4.10Minimum air flow m3/s 0.083 0.139 0.194 0.25 0.25 0.389 0.389 0.695 0.695 0.834 0.834Maximum air flow m3/s 0.333 0.694 1.028 1.583 1.583 2.361 2.361 3.889 3.889 5.000 5.000V air filter section m/s 1.21 1.42 1.42 1.16 1.45 1.18 1.57 1.59 1.91 1.65 1.98Recovery efficiency EN308* % 78.8 79.4 79.3 78.8 79.9 79.1 79.5 79.3 77.9 79.5 78.4Width x height mm 810 x

9581010 x 1158

1210 x 1359

1510 x 1659

1510 x 1659

1810 x 1959

1810 x 1959

1920 x 2090

1920 x 2090

2192 x 2340

2192 x 2340

Length mm 1266 510 + 800

800 + 800

800 + 800

800 + 800

800 + 800

800 + 800

1100 + 1100

1100 + 1100

1100 + 1200

1100 + 1200

Weight kg 201 309 432 558 604 702 751 955 955 1250 1250Supply power kW 1.43 2.5 3.82 4.23 4.23 6.03 6.03 12.06 12.06 15.45 15.45Supply Phase 1Ø 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + TPrice** £ 7,517 9,871 12,262 13,998 15,674 17,260 18,937 22,231 22,231 26,161 26,161

Floway Classic hot water coil (1-row) - inside the unitFan motor assembly supply W 289 517 808 940 1150 1407 2070 2576 3014 3631 4109Fan motor assembly exhaust W 266 473 715 882 1043 1334 1911 2213 2593 3095 3484Specific fan power kW/m3s 1.850 1.798 1.692 1.584 1.625 1.612 1.809 1.710 1.808 1.770 1.852Heating water coil capacity*** kW 4.0 7.3 11.9 15.2 17.9 22.5 29.1 37.1 41.1 50.3 54.3Price** £ 8,156 10,589 13,140 15,003 16,680 18,498 20,174 23,708

(2-row)23,708 (2-row)

27,738 (2-row)

27,738 (2-row)

Floway Classic cooling and heating/cooling only coil (2-row) - inside the unitFan motor assembly supply W 317 546 866 997 1219 1463 2166 2783 3481 4135 4707Fan motor assembly exhaust W 266 473 715 882 1043 1334 1911 2213 2593 3095 3484Specific fan power kW/m3s 1.945 1.852 1.756 1.633 1.676 1.645 1.853 1.784 1.959 1.903 1.998Changeover coil capacity (heating)***

kW 4.0 7.3 11.9 15.2 17.9 22.5 29.1 37.1 41.1 50.3 54.3

Changeover coil capacity (cooling)****

kW 5.7 10.5 17.1 21.9 25.7 32.3 41.8 52.2 58.9 72.2 77.9

Price** £ 8,355 10,764 13,340 15,196 16,862 18,801 20,398 23,788 23,788 27,818 27,818* ERP regulation UE 1253/2014.** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.*** Capacity at (W 45-40°C).**** Capacity at (W 7-12°C).

Page 46: Price List 2017 - CIAT

46

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

FLOWAY CLASSICAir handling unit accessoriesRotary heat exchangerAccessoriesFloway Classic 1000 2000 3000 4000 5000 6000 7500 10000 15000DescriptionFilter - F9 HEE £ 77 115 132 232 232 271 271 321 362Water coil H & C/CO (4-row) - inside the unit £ - - - - - - - 2,076 2,315Water coil HO (1-row) - additional casing £ 1,022 1,182 1,413 1,669 1,669 2,044 2,044 - -Water coil H & C/CO (2-row) - additional casing £ 1,142 1,277 1,533 1,780 1,780 2,188 2,188 - -Water coil H & C/CO (3-row) - additional casing £ 1,237 1,477 1,836 - - 3,034 3,034 - -Water coil H & C/CO (4-row) - additional casing £ - - - 2,554 2,554 - - - -Electric heater (1-stage) – inside the unit £ 878 974 1,118 1,214 1,261 1,429 1,477 - -Electric heater (2-stage) – inside the unit £ 942 1,086 1,205 1,205 1,341 1,509 1,557 1,847 3,209Electric heater (1-stage) – additional casing £ 1,261 1,437 1,652 1,876 1,924 2,235 2,283 - -Electric heater (2-stage) – additional casing £ 1,326 1,549 1,741 1,956 2,004 2,315 2,362 - -Motorised damperDimensions

£ 128 168 343 375 375 415 415 415 527250 dia 355 dia 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880

Outdoor motorised damperDimensions

£ 296 312 343 375 375 415 415 415 527mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880

Flexible sleeve (intake OR discharge) £ 17 20 76 91 91 112 112 112 128Dimensions mm 250 dia 355 dia 990 x 510 990 x 510 1290 x 610 1590 x 810 1590 x 810 1590 x 810 1900 x 810Partial mixing section(internal recycling damper)

£ 200 224 271 296 296 319 319 527 575

Total mixing section(internal recycling + 2 external dampers)

£ 790 846 958 1,046 1,046 1,149 1,149 1,357 1,629

Roof £ 346 363 389 449 449 518 518 583 647Hood £ 184 200 228 256 256 287 287 359 447Separator screen for hood £ 28 44 80 96 96 119 119 168 200Adjustable feetQuantity

£ 64 96 128 128 128 128 128 128 1284 6 8 8 8 8 8 8 8

Epoxy coating for rotary heat exchanger £ 231 352 471 567 655 767 1,022 1,261 1,676Hygroscopic coating for rotary heat exchanger £ 152 191 231 263 335 375 487 583 734Pre-painted fins on coils – 1-row £ 6 11 13 26 26 42 42 - -Pre-painted fins on coils – 2-row £ 11 20 33 51 51 82 82 95 128Pre-painted fins on coils – 3-/4-row £ 19 33 39 102 102 125 125 188 256Multi-units display (1-30) (display + TCONN card) £ 359 359 359 359 359 359 359 359 359LON PCB £ 280 280 280 280 280 280 280 280 280KNX PCB £ 280 280 280 280 280 280 280 280 280Modbus TCP – BACnet IP PCB £ 359 359 359 359 359 359 359 359 359∆P sensor for HR icing management £ 119 119 119 119 119 119 119 119 119IAQ sensor kit (CO2) £ 559 559 559 559 559 559 559 559 559Constant pressure management kit £ 203 203 203 203 203 203 203 203 203Ambient in-room control kit £ 184 184 184 184 184 184 184 184 184Smoke detector kit £ 319 319 319 319 319 319 319 319 319RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53 14/53 14/53 14/53 14/53

Page 47: Price List 2017 - CIAT

47

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

FLOWAY CLASSICAir handling unit

Plate heat exchanger

• Counter flow ‘plug and play’ air handling unit.• Double filtration (F7 and F9).• Plate heat exchanger with variable speed.• Free cooling and night cooling management.• EC fan motor.• Electrical pre-heater available = -15°C heat recovery.• Casing mechanical strength = D2.• Air leakage (± pressure) = L2.• Air leakage filter assembly = F9.• Thermal transmittance = T3.• Thermal bridge = TB2.

Floway Classic 1000 2000 3000 4000 6000Air flow m3/s 0.30 0.55 0.90 1.15 1.70Minimum air flow m3/s 0.083 0.139 0.194 0.250 0.389Maximum air flow m3/s 0.333 0.694 1.028 1.583 2.361V air filter section m/s 1.21 1.42 1.42 1.16 1.18Recovery efficiency EN308* % 81.0 85.8 85.2 85.4 84.7Width x height mm 810 x 958 1010 x 1158 1210 x 1359 1510 x 1659 1810 x 1959Length mm 1580 1150 + 800 1264 + 800 1264 + 800 1407 + 800Weight kg 200 350 465 580 765Supply power kW 1.43 2.50 3.82 4.23 6.03Supply Phase 1Ø 3Ø + T 3Ø + T 3Ø + T 3Ø + TPrice** £ 7,517 9,871 12,262 13,998 17,260

Floway Classic hot water coil (1-row) - inside the unitFan motor assembly supply W 284 520 876 1010 1581Fan motor assembly exhaust W 253 483 798 941 1517Specific fan power kW/m3s 1.790 1.824 1.860 1.697 1.822Heating water coil capacity*** kW 6.1 11.2 17.3 23.5 34.7Price** £ 8,156 10,589 13,140 15,003 18,498

Floway Classic cooling and heating/cooling only coil (2-row) - inside the unitFan motor assembly supply W 312 550 933 1063 1637Fan motor assembly exhaust W 253 483 798 941 1517Specific fan power kW/m3s 1.881 1.878 1.923 1.743 1.855Changeover coil capacity (heating)*** kW 6.1 11.2 17.3 23.5 34.7Changeover coil capacity (cooling)*** kW 5.7 10.5 17.1 21.9 32.3Price** £ 8,355 10,764 13,340 15,196 18,801* ERP regulation UE 1253/2014.** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.*** EN308 conditions: Dry performance, altitude 0 m, iso air flow: Fresh air 5°C/80%; Exhaust air 25°C/27%.

Page 48: Price List 2017 - CIAT

48

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

FLOWAY CLASSICAir handling unit accessoriesPlate heat exchangerAccessoriesFloway Classic 1000 2000 3000 4000 6000DescriptionFilter - F9 HEE £ 77 115 132 232 271Water coil HO (1-row) - additional casing £ 1,022 1,182 1,413 1,669 2,044Water coil H & C/CO (2-row) - additional casing £ 1,142 1,277 1,533 1,780 2,188Water coil H & C/CO (3-row) - additional casing £ 1,261 1,437 1,836 - 3,034Water coil H & C/CO (4-row) - additional casing £ - - - 2,554 -Electric heater (1-stage) – inside the unit £ 878 974 1,118 1,214 1,429Electric heater (2-stage) – inside the unit £ 942 1,086 1,205 1,205 1,509Electric pre-heater (1-stage) – inside the unit £ 1,009 1,149 1,322 1,501 1,788Electric heater (1-stage) – additional casing £ 1,261 1,437 1,652 1,876 2,315Electric heater (2-stage) – additional casing £ 1,326 1,549 1,741 1,956 2,315Motorised damperDimensions, mm

£ 128 168 343 375 415mm 250 dia 355 dia 1150 x 560 1450 x 650 1750 x 840

Outdoor motorised damperDimensions, mm

£ 296 312 343 375 415mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1750 x 840

Flexible sleeve (intake OR discharge) £ 17 20 76 91 112Dimensions, mm mm 250 dia 355 dia 990 x 510 990 x 510 1590 x 810Roof £ 346 363 389 449 518Hood £ 184 200 228 256 287Separator screen for hood £ 28 44 80 96 119Adjustable feetQuantity

£ 64 96 128 128 1284 6 8 8 8

Epoxy coating for plate heat exchanger £ 231 352 526 706 1,099Pre-painted fins on coils – 1-row £ 6 11 13 26 42Pre-painted fins on coils – 2-row £ 11 20 33 51 82Pre-painted fins on coils – 3-/4-row £ 19 33 39 102 125Multi-units display (1-30) (display + TCONN card) £ 359 359 359 359 359LON PCB £ 280 280 280 280 280KNX PCB £ 280 280 280 280 280Modbus TCP – BACnet IP PCB £ 359 359 359 359 359∆P sensor for HR icing management £ 119 119 119 119 119IAQ sensor kit (CO2) £ 559 559 559 559 559Constant pressure management kit £ 203 203 203 203 203Ambient in-room control kit £ 184 184 184 184 184Smoke detector kit £ 319 319 319 319 319RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53

Page 49: Price List 2017 - CIAT

49

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

FLOWAY VERTICALAir handling unit

• Self-supporting construction.• Double-wall casing with 50 mm insulation.• Pre-lacquered outer panel, galvanized inner panel.• Panel colour RAL 7035 and RAL 7024.• Fire rating A1/M0.• Air speed 300-2,600 m3/h.• Wide range of options available.• For indoor use with compact unit dimensions.• Plug fan with brushless EC motor.• Carel pC03 controller included.• Counter-flow heat exchanger.

Floway Vertical 700 1500 2000Minimum air flow m3/h 300 700 700Maximum air flow m3/h 1200 2000 2600Maximum power input kW 1.43 2.50 2.50Maximum current A 6.2 3.6 3.6Width x height mm 700 x 1340 800 x 1712 800 x 1854Length mm 1272 1550 1692Weight kg 202 330 389Power supply V/ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50

Floway Vertical Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, displayPrice £ 7,279 9,125 10,382

AccessoriesDescription Size 700 Size 1500 Size 2000Intake motorised damper £ 128 168 168Flexible intake sleeve £ 17 20 20Built-in single-stage electric heater £ 671 886 1,078Built-in 1-row heating coil with valves £ 671 702 734External single-stage electric heater £ 1,261 1,4137 1,437External 1-row heating coil with valves £ 1,248 1,182 1,182External 2-row heating/cooling coil with valves £ 1,142 1,277 1,277External 3-row heating/cooling coil with valves £ 1,237 1,477 1,477

Page 50: Price List 2017 - CIAT

50

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

FLOWAY CEILINGAir handling unit

• Self-supporting construction.• Double-wall casing with 50 mm insulation.• Pre-lacquered outer panel, galvanized inner panel.• Panel colour RAL 7035 and RAL 7024.• Fire rating A1/M0.• Air speed 300-1,900 m3/h.• Wide range of options available.• For indoor use with compact unit dimensions.• Plug fan with brushless EC motor.• Carel pC03 controller included.• Counter-flow heat exchanger.

Floway Ceiling 700 1200 1600Minimum air flow m3/h 300 500 600Maximum air flow m3/h 1000 1400 1900Maximum power input kW 1.43 1.43 2.50Maximum current A 6.2 6.2 3.6Width x height mm 896 x 557 1174 x 557 1456 x 557Length mm 1359 1498 1762Weight kg 161 206 279Power supply V/ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50

Floway Ceiling Hot Water Coil Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, displayPrice £ 6,646 8,528 9,958

AccessoriesDescription Size 700 Size 1200 Size 1600Intake motorised damper £ 202 223 223Flexible intake sleeve £ 29 33 33External single-stage electric heater £ 1,261 1,341 1,413External 1-row heating coil with valves £ 1,022 1,182 1,182External 2-row cooling coil with valves £ 1,142 1,277 1,277External 3-row heating/cooling coil with valves £ 1,237 1,477 1,477

Page 51: Price List 2017 - CIAT

51

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

HELIOTHERME 4000Air heater/chiller

• Indirect-fired air heater and/or air chiller.• Fan motor with ROTOREX technology for efficient air flow

and quiet operation.• Double distributor with standard JET+ technology.• One unit model for both vertical and horizontal usage.• Highly efficient heat exchanger.• Built-in antibacteria condensate drain pan with paddle

connectors for cooling or reversible heating operation.• Wide choice of accessories.• Comprehensive range of controls for each operation (on/off,

proportional, electric heater, etc.).• Optional unit available with energy-efficient HEE motor.

For heating (power supply 230 V - 1 ph - 50/60 Hz)Unit No. of rows Power Air speed Air throw Part Number Total price, £

W m3/h m4350 1 13900 2600 22 B400000, B400074, B400025 492

2 24800 2400 20 B400000, B400074, B400026 5413 30100 2075 15 B400000, B400074, B400027 591

4400 1 20200 4200 26 B400005, B400078, B400034 6032 37100 3800 23 B400005, B400078, B400035 6513 46500 3450 23 B400005, B400078, B400036 704

4450 1 27300 5200 27 B400010, B400082, B400043 6872 48500 4700 21 B400010, B400082, B400044 7543 63000 4550 18 B400010, B400082, B400045 813

4500 1 36300 7100 28 B400015, B400086, B400052 8292 65500 6600 26 B400015, B400086, B400053 9223 85900 6200 24 B400015, B400086, B400054 1,004

4630 1 53200 10450 28 B400020, B400090, B400061 1,0952 97900 9610 24 B400020, B400090, B400062 1,2023 122000 8280 21 B400020, B400090, B400063 1,298

The above units are also available with 400 V power supply. The heating capacities and air flows will vary. Please contact us for more information.

For cooling (power supply 230 V - 1 ph - 50/60 Hz)Unit No. of rows Power Air speed Air throw Part Number Total price, £

W m3/h m4350 3 4780 1640 23 B400000, B400076, B400027 5914400 3 6680 2160 26 B400005, B400080, B400036 7044450 3 10100 3025 24 B400010, B400084, B400045 8324500 3 13800 4060 23 B400015, B400088, B400054 1,0264630 3 21400 5960 21 B400020, B400092, B400063 1,292

Available unit optionsDescription Part Number Total price, £Wall mounting/ceiling mounting kit 7181226/7185116 53/455-speed transformer kit 7166982 117The above capabilities are based on Eurovent conditions. For cooling with an air inlet temperature of 25°C/50% RH and a water range of 7-12°C, heating with an air inlet temperature of 15°C/50% RH and a water range of 90-70°C at high fan speed. CIAT participates in the Eurovent certification program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.

Page 52: Price List 2017 - CIAT

52

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

SPACEPackaged unit

• High efficiency cooling circuits for R410A with electronic expansion valves and scroll compressor.

• Electronic axial fans for low noise level.• Multiple recovery options on the extracted air energy.• Heating back-up options: electric heaters, hot water

coil, gas burner or boiler.• Plug-fans (free-wheel) with EC motors.• Available as Cooling Only, Heat Pump, Heat Recovery

models.

Space IPJ 90 120 140 160 180 190 200 220 240 280 320 360 380Cooling capacity kW 22.5 28.3 34.7 38.6 42.9 45.5 53.1 57.7 60.3 67.7 71.3 80.2 90.0Power input kW 7.3 9.4 11.0 12.6 14.2 15.1 17.2 19.1 20.1 21.9 23.4 26.4 29.9EER 3.10 3.01 3.16 3.06 3.01 3.01 3.09 3.03 3.01 3.09 3.05 3.04 3.01Heating capcaity kW 22.0 28.1 33.7 38.2 42.4 45.3 51.5 56.7 59.5 67.9 72.2 80.8 90.9Power input kW 6.0 8.0 9.6 10.9 12.3 13.3 15.0 16.6 17.4 19.5 20.9 23.6 26.7COP 3.67 3.50 3.53 3.50 3.44 3.41 3.44 3.42 3.41 3.49 3.45 3.43 3.41Outdoor circuit fan air flow m3/h 9.0 14.5 17.0 17.0 17.0 17.8 31.0 31.0 31.0 33.0 33.0 34.5 35.0Available static pressure Pa 49 49 49 49 49 49 49 49 49 49 49 49 49Indoor circuit supply fan air flow m3/h 5.1 6.5 8.7 9.25 9.45 9.45 12 12.5 12.5 16 16 16.5 16.5Available static pressure Pa 117 117 117 147 147 147 196 196 196 196 196 245 245Power supply V/ph/Hz 415/3/50Maximum absorbed current A 18.5 26.5 30.5 33.5 37.5 38.0 44.3 49.9 50.1 50.2 53.7 62.3 67.5Refrigerant charge kg 6.7 7.0 11.0 11.0 11.5 11.5 12.5 12.5 13.0 19.5 19.5 20.0 20.0Weight kg 585 610 675 680 685 690 990 995 1040 1155 1160 1165 1170Sound power level dB(A) 71 80 80 84 85 85 85 85 85 85 85 86 86Price £ TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBCCooling capacity in accordance with EN-14511-2013 for indoor temperature conditions 27ºC,19ºC WB and 35ºC outdoor temperature.Heating capacity in accordance with EN-14511-2013 for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature.Total power input by compressor and motorised fans under nominal conditions in accordance with EN-14511-2013.

New product launch

July 2017

Page 53: Price List 2017 - CIAT

53

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

SPACEPackaged unit options and accessories

Family Description In factory On site Price, £Electrical power 400 V/3 ph/50 Hz (without neutral) ✓ TBCFlow and assembly

CS: Cross flow with 2 dampers ✓ TBCCK: Cross flow with 3 dampers ✓ TBCCA: Cross flow with axial return fan ✓ TBCCP: Cross flow with lower return plug-fan ✓ TBCCQ: Cross flow with upper return plug-fan ✓ TBCCW: Cross flow with passive recovery ✓ TBCTS: Tunnel flow with 2 dampers (for models 0200 to 0380) ✓ TBCTP: Tunnel flow with return plug-fan (for models 0200 to 0380) ✓ TBCTW: Tunnel flow with passive recovery (for models 0200 to 0380) ✓ TBC

Coil coating Coil with copper pipes and copper fins ✓ TBCCoil with copper pipes and fins of an aluminium alloy (INERA®) ✓ TBCCoil with copper pipes and aluminium fins with polyurethane coating ✓ TBCCoil with copper pipes and aluminium fins with Blygold® coating ✓ TBC

Heating Auxiliary hot water coil: standard or great cold ✓ ✓ TBCAuxiliary electrical heaters ✓ ✓ TBCNatural or propane gas burner ✓* TBCGas boiler and auxiliary hot water coil ✓ TBC

Protection low temperature

Antifreeze protection kit for low temperature (<-10ºC) ✓ TBCAntifreeze protection kit for low temperature (<-14ºC) ✓ TBC

Indoor fan High available pressure of the indoor fan ✓ TBCLow available pressure of the indoor fan ✓ TBC

Air filtration and stop-drop

Stop-drop in the indoor air coil ✓ ✓ TBCGravimetric filters G4 with low pressure drop ✓ ✓ TBCGravimetric filters G4 + folded opacimetric filters M6, F7 or F9 ✓ ✓ TBCGravimetric filters G4 low pressure drop + folded opacimetric filters F7 or F9 ✓ ✓ TBCDouble stage of folded opacimetric filters (M6+F7, M6+F9, F7+F9 or F9+F9) ✓ ✓ TBC

Outdoor fan Axial 2-speed outdoor fan(s) directly coupled to the motor ✓ TBCInsulation Ceramic fibre for thermal and acoustic insulation, Euroclass A2-s1, d0 (M0) ✓ TBCIndoor unit Condensate drain pan in stainless steel ✓ ✓ TBC

Management of the overpressure ✓ TBCDifferential pressostat for the detection of clogged filters ✓ ✓ TBC

Outdoor unit Outdoor coil protective grille ✓ ✓ TBCStop-drop at the fresh air intake ✓ ✓ TBCAnti-vibration mounts made of rubber ✓ ✓ TBC

Passive recovery Rotary heat exchanger with CW assembly ✓ TBCRotary heat exchanger with TW assembly ✓ TBC

Probes Ambient temperature probe: one NTC probe connected to the control board or one to four probes with RS485 communication

✓ ✓ TBC

Ambient temperatute and humidity probe: one to four probes with RS485 communication ✓ ✓ TBCCO2 air quality probe environment installed, duct-mounted or installed on a pLAN local network ✓ ✓ TBCSmoke detecting station in accordance with the NF S 61-961 standard ✓ ✓ TBC

Free-cooling and outdoor humidity

Type of free-cooling: thermal, enthalpic or thermoenthalpic ✓ ✓ TBCOutdoor air humidity probe: supplied with the unit or installed on a pLAN local network ✓ ✓ TBC

Terminal and unit communication

User terminal installed on the electric panel ✓ ✓ TBCUser terminal installed on the electric panel + graphic terminal remote up to 50 m or 200 m ✓ ✓ TBCUser terminal installed on the electric panel + graphic terminal remote up to 200 m ✓ ✓ TBCUnit configuration: stand-alone, master or slave ✓ ✓ TBCCommunication cards: RS485 Modbus/Carel; Ethernet PCoWeb; RS485 LonWorks®; Ethernet BACnetTM; RS485 BACnetTM; RS485 Konnex

✓ ✓ TBC

Miscellaneous item 1

Management of an humidifier with proportional or on/off control ✓ ✓ TBCEnergy meter ✓ ✓ TBCEnergy meter and calculation of the cooling and heating capacities ✓ ✓ TBC

Miscellaneous item 2

Compressor soft starter ✓ ✓ TBCTropicalised components on the electric panel: control board, cards and terminals ✓ TBCHigh performance phase monitoring relay ✓ TBCHigh performance magnetothermic switches ✓ TBC

Roofcurb Standardised pre-assembly roofcurbs with adjustable height (cross flow) ✓ TBCAdaptation roofcurbs for replacing units on site (tunnel flow) ✓ TBC

* The gas burner is supplied installed into a pre-assembly roofcurb.

Page 54: Price List 2017 - CIAT

54

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

Air product range of equipment

Air flow rates: up to 1.66 m3/s

AIR COMPACT

Water-Cooled/Heated Internal AHU

Air flow rates: 0.13 to 5 m3/s

FLOWAY

Plug & Play, Internal/External AHU

Air flow rates: 2.8 to 7 m3/s

CLIMACIAT

Bespoke AHUs for all applications including HTM 03 01

Heating capacity: 20 and 286 kWCooling capacity: 19 and 277 kWAir flow rates: up to 12.8 m3/s

SPACE

Roof Top Packaged Units

Cooling capacity: 5 to 130 kWAir flow rates: 0.28 to 3.35 m3/s

EXPAIR/MAGISTER

Close Control Units

Heating capacity: 20 and 286 kWCooling capacity: 19 and 277 kWAir flow rates: up to 12.8 m3/s

MAJOR/COMFORT LINECOADIS/MELODY CASSETTE

Fan Coils for every application

Heating capacity: 7 and 110 kWCooling capacity: 8 and 92 kWAir flow rates: 0.04 to 4.7 m3/s

HELIOTHERME

Air Heaters and Coolers, many versionsand applications

Heating capacity: 21 to 144.5 kWCooling capacity: 19 to 135 kWAir flow rates: up to 5.7 m3/s

AIRDUO/NEXIA/NEPTUS

Packaged Internal and Split Type Systems

Heating capacity: 69 and 148 kWCooling capacity: 92 and 148 kW

Water removal capacity: 4 to 120 kg/h

AQUAIR/AIRMASTER

Swimming Pool andDehumidification Systems

Page 55: Price List 2017 - CIAT

55

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

Chiller and heat pump range of equipment

Heating capacity: 42 to 162 kWCooling capacity: 38 to 160 kW

R410A scroll compressor

AQUACIAT

Air-Cooled HP Water Chiller

Heating capacity: 190 to 500 kWCooling capacity: 190 to 640 kW

R410A scroll compressor

AQUACIAT power

Air-Cooled HP Water Chiller

Cooling capacity: 600 to 1350 kWR134A screw compressor

POWERCIAT

Air-Cooled Water Chiller

Heating capacity: 40 to 210 kWCooling capacity: 35 to 180 kW

R410A scroll compressors

DYNACIAT

Water-Cooled Heat Pump/Chiller

Heating capacity: 250 to 820 kWCooling capacity: 220 to 720 kW

R410A scroll compressors

DYNACIAT power

Water-Cooled Heat Pump/Chiller

Heating capacity: 500 to 1400 kWCooling capacity: 370 to 1170 kW

R134A screw compressors

HYDROCIAT

Water-Cooled Heat Pump/Chiller

Cooling capacity: 8 to 1350 kWExtensive range of over 4500 models

VEXTRA/OPERA

Air-Cooled Dry Cooler/Condenser

Heating capacity: 4 to 40 kWCooling capacity: 4 to 40 kW

Air-cooled rotary and inverters

EREBA

Comprehensive Range ofReversible Heat Pumps

Heating capacity: 4 to 15 kWEnergy Class A++

YUNA II

Packaged Hot Water System with Buffer Tank/Expansion Vessel/Heat Exchanger

Page 56: Price List 2017 - CIAT

56

A leader in Cooling, Heating and Indoor Air Quality

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

Toshiba range of products and services

Heating capacity: 2 to 5.8 kWCooling capacity: 1.5 to 5 kW

RAS Split-System

Residential Range

Heating capacity: 4.4 to 12 kWCooling capacity: 4 to 10 kW

RAS Multi Split-System

Residential Range

Heating capacity: 8 to 16 kWWater storage volume: 150 to 300 l

Electric heater: 2.75 kW

Estía Air-to-Water Heat Pump

Hot Water System

Heating capacity: 3.4 to 27 kWCooling capacity: 2.5 to 23.7 kW

RAV Digital Inverter

Light Commercial Range (Compact and Lightweight Outdoor Units)

Heating capacity: 3.4 to 27 kWCooling capacity: 2.5 to 23.7 kW

RAV Super Digital Inverter

Light Commercial Range (Longer Pipe Runs and Higher Efficiency)

Heating capacity: 1.9 and 31.5 kWCooling capacity: 1.7 and 28 kW

VRF

VRF Indoor Units

Heating capacity: 12.5 to 18 kWCooling capacity: 12.1 and 15.5 kW

Mini VRF Outdoor Unit

MiNi-SMMSe - VRF 2-Pipe Heat Pump

Heating capacity: 25 to 178 kWCooling capacity: 22.4 to 168 kW

VRF Outdoor Unit

SMMSe - VRF 2-Pipe Heat Pump

Heating capacity: 63 to 171 kWCooling capacity: 56 to 152 kW

VRF High-Efficiency Outdoor Unit

SMMSe - VRF 2-Pipe High-EfficiencyHeat Pump

Page 57: Price List 2017 - CIAT

57

www.ciat.uk.comemail: [email protected]

tel.: 01372 220151

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

Toshiba range of products and services

Heating capacity: 25 to 135 kWCooling capacity: 22.4 to 120 kW

VRF Heat Recovery Outdoor Unit

SHRMe - VRF 3-Pipe Heat Recovery Unit

Standard and Premium Single-Port Box4- and 6-Way Multi-Port Box

VRF Flow Selector Boxes

SHRMe - 3-Pipe Heat Recovery Units

Heating capacity: 5.53 to 10.92 kWCooling capacity: 4.10 to 8.25 kW

Air flow: 150 to 2000 m3/h

VN Units (Air-to-Air Heat Exchangers)

Standard with DX Coil and/or Humidifier

Heating capacity: 3.4 to 178 kWCooling capacity: 2.5 to 168 kW

RAV and VRF

Air Handling Application DX Coils

Heating capacity: 8 to 16 kWDoor width: 1 m, 2 m and 2.5 m

DX Air Curtains

Split-System and VRF

Pre-Sales Support

Full Design and Support Service

Technical Support

24/7/364 Technical Support

Toshiba Rewards Scheme

The Original and Best Reward Scheme

Extended Warranty

Designed to Reward Competence

Page 58: Price List 2017 - CIAT

A leader in Cooling, Heating and Indoor Air Quality

58

When building and HVAC equipment or controls are not serviced or maintained your business is at risk

Service and maintenance is a year-round necessity in order to optimise efficiency, save money, help to make sound management decisions and free you from the anxiety of unplanned downtime.

With a CIAT maintenance contract you ensure regular service and maintenance requirements are met and you avoid the adverse consequences of neglect. CIAT makes it easy for you to select a level of service that’s right for your operation.

CIAT engineers are highly-skilled in all building systems assessment. They have access to advanced diagnostic tools and analysis software, which will quickly and accurately evaluate your entire infrastructure and identify opportunities for improvements and cost-savings.

Our engineers are industry-served, which gives CIAT the ability to service and maintain equipment from any manufacturer.

CIAT is one of the best-trained service providers in the industry. Our engineers are trained on the most up-to-date factory developments and all our engineers have to pass stringent health and safety tests along with ethics training.

Commissioning

We provide a full commissioning service carried out by professionally-trained, experienced engineers to ensure that once acquired, your equipment is set up to function correctly and efficiently in order to optimise its performance.

Commissioning service engineers

When choosing to use our commissioning service you can rest assured that all of our commissioning service engineers are:• Factory-trained to the highest standards by senior engineers who are involved in the actual design of the equipment.• Fully-equipped with the required test instruments (fully-calibrated with certification available on request).• Equipped with laptops and the software necessary to communicate with our controllers and unit strategies.

On-site instruction

In addition to our commissioning service we can also provide commissioning engineers for on-site instruction. This is useful for those responsible for day-to-day unit operation (if not already covered by a CIAT Service and Maintenance contract). Although this service is tailored to individual needs, it would typically include the following:• Provision of the controls and operating and maintenance manuals. Introduction to the content of these manuals,

allowing you to highlight what you feel to be relevant.• Basic navigation and explanation of the controller operation and alarm handling.• Discussion about the general maintenance of the unit, covering mechanical items such as belts, motors and

electrical items, e.g. the humidifier and electrical panel.

Page 59: Price List 2017 - CIAT

A leader in Cooling, Heating and Indoor Air QualityA leader in Cooling, Heating and Indoor Air Quality

59

WARRANTY AND MAINTENANCE

2-Year Enhanced• CIAT Commission.• CIAT Maintenance.

3-Year Enhanced• CIAT Commission.• CIAT Maintenance.

5-Year Comprehensive• CIAT Commission.• CIAT Maintenance.• Remote Monitoring.• Available on selected sites only.

Standard warranty is 12 months. Extended warranty must be activated within 30 days of system commissioning.

Thanks to CIAT M2M, you can monitor and control the correct operation of your installation remotely. This service improves the performance of your equipment, optimises its use and provides you with technical support from our experts in real time.

AHU FLAT PACK• Restrictive site access solutions can be achieved with CIAT

Ozonair’s AHU flat pack service. • Where access to a plant area is restricted CIAT Ozonair

engineers can either off-load and build as required or build units placed in situ by others.

• This approach can help minimise disruption on site and to the customer.

• Flat pack installation of air handling units and other CIAT Ozonair products can also save costs on builders’ work, crane hire and potential road closures.

AHU AND PACKAGED AC REFURBISHMENT• Practical alternative to replacing with new equipment.• Cost of refurbishment can save between 50 and 65% of system replace-

ment cost, as well as offer savings in time and expense by obviating the need for lifting equipment and potential road closures.

• Itemised quotations, to enable essential works to be carried out first, followed by staged improvement works to the equipment.

• Staged and scheduled works to reduce disruption to the client and help with budgetary requirements.

• Reduce running costs by installing more efficient components.• Services include replacement of casework, gas burners, cooling coils,

heat recovery, higher grade filtration or upgrading fan performance.

Page 60: Price List 2017 - CIAT

Porsham Close,Roborough,Plymouth,Devon, PL6 7DB

Head Office

Northern Office

Registered Office

United Technologies House,Guildford Road,Leatherhead,Surrey, KT22 9UT

Parkfield House,Manchester Old Road,Middleton,Manchester, M24 4DQ

www.ciat.uk.com

UK Contacts

Sales & [email protected]

01372 220151

Technical [email protected]

01372 220298

Service [email protected]

01372 220151

This document is not binding. As part of its policy for continual product improvement, CIAT reserves the right to make any product improvements without prior notification. All reproduction rights reserved. None of the content in this document may be reproduced, transmitted, sold, commercially exploited, or reused in any manner.

CIAT products are available from: