primergy installation raid basics fujitsu siemens computers training documentation

36
PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

Upload: dania-massengale

Post on 11-Dec-2015

243 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

PRIMERGY InstallationRAID Basics

Fujitsu Siemens Computers training documentation

Page 2: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved2

SAS/SATA Comparison

Page 3: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved3

Disk Interface Comparison

Source: Fujitsu

Page 4: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved4

Mixing of SAS and SATA Disks

Page 5: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved5

RAID Basics

Page 6: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved6

Redundant Array of Independent DisksA way of organizing several disks to provide performance OR resilience:

Tolerant to a disk failure

Types of RAID:

Standard: Level 0 - 5

Vendor Specific: 7 >

Associated technology

Hot plug

Hot Spare

More about RAID and RAID sizing on Student CD

disk_subsystem_sizing_-_raid_controller_1.0__en_.pdf

What is RAID ?

Page 7: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved7

RAID Level 1+0 (10): Striped Mirrored Sets

Host System

Disk Array Controller (DAC)

Resilience

Reads Cost

Writes

Data Disk 1

Mirrored Disk 1

Mirrored Disk 1

Data Disk 1

Page 8: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved8

RAID Level 7: JBOD – Just a bunch of disks

Host System

Disk Array Controller (DAC)

JBOD

Just a way of declaring normal disks under a RAID controller.

(May include COD information)

Page 9: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved9

RAID 1E: An LSI specific Level

Host System

Disk Array Controller (DAC)

Data Disk 1

Mirroring over more than two disks.

During the “Mylex era” this was called Mylex-RAID 6, This is confusing since there

is a standard RAID level called RAID6 that has a completely different function

Data Disk 2 Data Disk 3

33

44

2

21 1

Page 10: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved10

Standard O/S Support Windows 2000/2003 includes RAID 0, 1 & 5 Netware offers RAID 0, 1, 5 & 10 Unixware offers Online Storage Manager (0, 1, 0+1 & 5) Redhat & Suse Linux Include RAID 0, 1 & 5

Fujitsu-Siemens products DDM, Duplex Data Manager, Includes RAID 1 w Hot-spare(Important for MS Cluster configuration )

Implications of Software RAID

RAID 5/3 needs a Math Co-processor (for parity creation)

RAID often not supported on System/boot Partition (Except for FSC DDM)

No instant fail-over ( Except for FSC DDM)

Hot-Plug Support requires HW Control Mechanism.

Software RAID Support

Page 11: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved11

Cache Policy

Write back Only enable with BBU or UPS Support

Write Through Does not use cache Big Impact on Parity RAID performance

Predictive cache (Read Ahead pattern matching) (for RAID disable it) Switch off – most requests are not synchronous

Cache Size

Must Support BBU for a weekend.

Larger cache boosts parity raid if using write back policy

HW RAID

Page 12: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved12

RAID 2,5 “ and 3,5 “

Page 13: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved13

PRIMERGY RX300/RX200 S3 - 2.5-inch HDD

6 x 3.5” Hot-plug HDD

12 x 2.5” Hot-plug HDD

2 x 3.5” Hot-plug HDD

4 x 2.5” Hot-plug HDD

RX200 S3 RX300 S3

2 x 2.5” Hot-plug HDDTX120

Page 14: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved14

SATA / SAS HDDs 06/2007

Size Technology Rotation Capacity

3,5" SAS 15k36, 73, 146, 300 GB

2,5" SAS 15k 36, 73 GB

3,5" SAS 10k36, 73, 146,300 GB

2,5" SAS 10k 36, 73, 146 GB

3,5" SATA 7.2k80, 160,250, 500, 750 GB

Page 15: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved15

  SAS HDD SATA HDD

    R 0/1/10 R5/50 R 0/1/10 R5/50

TX150 S5

SATA Base Unit - -Onboard LSI MegaSR

=ICH7R

ICH 7R + ibutton option(Windows only)

or LSI MegaRAID SATA 8308ELP (Altair)

SAS Base UnitOnboard LSI 1068

IME

MegaRAID ZCR-SAS - LSI 8300XLP

Onboard LSI 1068 IMEMegaRAID ZCR-SAS -

LSI 8300XLP

TX200 S3SATA Base Unit - - Onboard ESB2

Onboard ESB2 + ibuttonOr RAID5 Embedded MegaRAID SW LSI

SAS Base UnitOnboard LSI 1068

IMEZCR-SAS - LSI

8300XLPOnboard LSI 1068 IME

(p)ZCR-SAS - LSI 8300XLP

TX300 S3RX300 S3

(Common Base Unit)

Onboard LSI 1068 IME

LSI MegaRAID SAS

ROMB

Onboard LSI 1068 IME LSI MegaRAID SAS ROMB

RX100 S4SATA Base Unit - -

Embedded SATA software RAID ICH7R (R

0/1) -

SAS Base UnitOnboard LSI 1068

IME-

Onboard LSI 1068 IME (p)

-

RX200 S3(Common Base Unit)

Onboard LSI 1068 IME

ZCR-SAS - LSI 8300XLP

Onboard LSI 1068 IME ZCR-SAS - LSI 8300XLP

SCSI/ SATA / SAS HDD and Controllers

Page 16: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved16

LSI RAID Controller on Board

Page 17: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved17

SAS / SATA

Motherboard

Enterprise

Southbridge2

(ESB 2)

TX200 S3 onboard SATA RAID 1/0 with ESB2

ESB2 = RAID 0/1 + opt Key for RAID5

Page 18: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved18

TX200 S3 onboard SATA RAID 1/0 with ESB2

Page 19: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved19

SAS / SATA

Motherboard

SAS Ctrl.

LSI 1068

PCI-X 133

RX300 S3 onboard IME RAID 1/1E

Page 20: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved20

LSI SAS Raid

To enter the controller press <CTRL+C>

Page 21: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved21

LSI SAS Raid

Automatic Rebuild

Supports Hot Spare Disk

Page 22: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved22

SAS / SATA

Motherboard

Flash ROM

Raid Firmware

Stack (LSI)

iButton

(Raid Key)

IOP

(Intel Brockton)

SAS Ctrl.

LSI 1068

Standard DDR2-533 / 667 DIMM Module

256 MB ECC with BBU ( 72 Std. hold time ), 256 MB without

BBU

PCI-X 133

PCI-

Express

Modules with BBU have Charge Circuit integrated

RX300 S3 onboard RAID5 with INTEL Brockton IOP block diagram

Page 23: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved23

LSI Web BIOS

Page 24: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved24

LSI pluggable PCI RAID Controllers

Page 25: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved25

LSI MegaRAID SAS abcd

ab--> Type,

c --> external SAS connections

d --> internal SAS connections

Example LSI MegaRAID SAS 8344ELP 83 Type 4 external connections 4 internal connections

LSI controller naming

Page 26: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved26

pluggable RAID controller

Onboard RAID extension (ZCR) 8300XLP

LSI MegaRAID SATA 8803ELP

LSI MegaRAID SAS 8344ELP For disk Expansion with SX40

LSI MegaRAID SCSI 320-2xFor disk Expansion with SX30

Page 27: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved27

LSI Web BIOS

Page 28: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved28

pluggable RAID controller

Onboard RAID extension (ZCR) 8300XLP

Page 29: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved29

SAS

PCI

ZCR card must be in correct slot that has the logic to enable it to utilise the onboard SCSI or SAS

Most modern FSC motherboards colour code this blue

Match LSI ZCR with LSI chip on motherboard

Tx150S5,RX200S3 and Tx200S3

Zero Channel RAID

Page 30: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved30

pluggable RAID controller

LSI MegaRAID SAS 8344ELP For disk Expansion with SX40

Page 31: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved31

Customer Rules Only FibreCAT SX40 disk drives are released. SAS drives from FibreCAT SX60/80 are not

compatible!

Controller is released for FibreCAT SX40 connection only

Controller is not released for internal connection

Max. SAS cable length between controller – box / box – box is 2 m

FibreCAT SX40 must be up before power on of connected controller/server and Controller/server must be powered off before FibreCAT SX40

Redundant path configurations (using two I/O-Modules) are not released

Controller is not released for use as a shared Cluster device in Cluster Configurations

It is strongly recommended to save RAID configurations with MegaCLI

Controller Hotplug is not released

FibreCAT SX40 Hotplug is not released

Tape devices and optical devices (e.g. DVD) are not supported

OS boot from FibreCAT SX40 will be supported with next major release

Replacing a Hot Spare by a new hard disk, this new hard disk stops being handled as Hot Spare in SAS firmware. You need to reconfigure this new hard disk as Hot spare.

LSI MegaRAID SAS 8344ELP For disk Expansion with SX40

Page 32: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved32

RAID Options

*reboot during Capacity extension and RAID migration is not allowed

Page 33: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved33

Lab - General

Lab General Explain Signs

Explain Shares

\\192.168.xx.200\Download\

Page 34: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved34

Lab – General

Page 35: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved35

Exercise 02

Configure LSI IME SAS and SATA

Page 36: PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation

RAID Basics PRIMERGY Installation Release November 2007 © Fujitsu Siemens Computers 2007 All rights reserved36

Exercise 03

Configure LSI Web BIOS