J
2
OC
3
4
P
K
M
JJ
C
DESCRIPTIONSYMBOL
ELECTRICAL SYMBOL LEGEND
MTG. HT.
SINGLE POLE SINGLE THROW TOGGLE SWITCH
TWO SINGLE POLE SINGLE THROW TOGGLE SWITCHES AND BALLASTCOMBINATION TO CONTROL OUTER LAMPS ON ONE SWITCH AND INNER LAMP(S)ON THE OTHER SWITCH
DOUBLE POLE SINGLE THROW TOGGLE SWITCH
THREE�WAY TOGGLE SWITCH
FOUR�WAY TOGGLE SWITCH
SINGLE POLE SINGLE THROW TOGGLE SWITCH WITH PILOT LAMP
SINGLE POLE SINGLE THROW KEYED TOGGLE SWITCH
SINGLE POLE SINGLE THROW PRESSURE TYPE TOGGLE SWITCH
MANUAL MOTOR RATED SWITCH WITH OVERLOAD PROTECTION
DIMMER SWITCH
THREE�WAY DIMMER SWITCH
INFRARED OCCUPANCY SENSOR WITH MANUAL ON/OFF SWITCH
ULTRASONIC OCCUPANCY SENSOR, WALL / CEILING MOUNTED
INFRARED OCCUPANCY SENSOR, WALL / CEILING MOUNTED
DUAL TECHNOLOGY OCCUPANCY SENSOR, WALL / CEILING MOUNTED
OCCUPANCY SENSOR POWER PACK
ELECTRICAL ABBREVIATIONS
ALTERNATING CURRENTAC
ABOVE FINISHED FLOORAFF
ABOVE FINISHED GRADEAFG
ALUMINUMAL
AUTOMATIC TRANSFER SWITCHATS
AMERICAN WIRE GAUGEAWG
BELOW CEILINGBC
BREAKERBKR
COMMUNITY ACCESS TELEVISIONCATV
CIRCUIT BREAKERCB
CLOSED CIRCUIT TELEVISIONCCTV
CIRCUITCKT
CEILINGCLG
CONDUIT ONLYCO
CONTROLCNTL
CENTRAL PROCESSING UNITCPU
COPPERCU
CURRENT TRANSFORMERCT
DIRECT CURRENTDC
DELTA
DIMMERDIM
DISCONNECT SWITCHDISC
DOWNDN
EMERGENCYE
EMPTY CONDUITEC
EXISTINGEX
FIRE ALARMFA
FIRE ALARM CONTROL PANELFACP
FEEDERFDR
FLOORFL
FUSE OR FUSEDF
FULL VOLTAGE NON�REVERSINGFVNR
GENERATORGEN
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FAULT PROTECTIONGF
GALVANIZED RIGID STEEL CONDUITGRC OR GRS
GROUNDG OR GND
HEIGHTH OR HT
HIGH INTENSITY DISCHARGEHID
HORSEPOWERHP
HAND�OFF�AUTOMATICHOA
HERTZHZ
ISOLATED GROUNDIG
ISOLATEDISO
JUNCTION BOXJ OR JB
KILO, THOUSANDK
THOUSAND CIRCULAR MILLSKCMIL
LIGHT EMITTING DIODELED
MOTORM
MASTER ANTENNA TELEVISIONMATV
MAIN CIRCUIT BREAKERMCB
MOTOR CONTROL CENTERMCC
MAN HOLEMH
MAIN LUGS ONLYMLO
MOUNTMT
MOUNTINGMTG
NORMALLY CLOSEDNC
NATIONAL ELECTRICAL CODENEC
NON FUSEDNF
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NOT IN CONTRACTNIC
NIGHT LIGHTNL
NORMALLY OPENNO
NOT TO SCALENTS
ON CENTEROC
OVERLOADOL
POLEP
PHOTOELECTRIC CONTROLPC
PANELBOARDPNL
POTENTIAL TRANSFORMERPT
POLY�VINYL CHLORIDEPVC
RELAYR
REMOTE CONTROLRC
RECEPTACLERECPT
REFERENCEREF
ROOT MEAN SQUARERMS
SUB FED LUGSSFL
SYMMETRICALSYM
SWITCHSW
SWITCHBOARDSWBD
TELEPHONE BACKBOARDTBB
TELEPHONETEL
TELEVISIONTV
TRANSIENT VOLTAGE SURGE SUPRESSORTVSS
TYPICALTYP
UNDERGROUNDUG
UNDERWRITER'S LABORATORYUL
UNINTERRUPTED POWER SUPPLYUPS
VOLTSV
VOLT�AMPEREVA
WATTSW
WEATHERPROOF WHILE IN USEWP
TRANSFORMERXFMR
EXPLOSION PROOFXP
WYEY
IMPEDANCEZ
WHERE ABBREVIATIONS ARE USED IN THE DOCUMENTS ANDNOT LISTED IN THE FOLLOWING, REFER TO ANSI/IEEE STANDARD100 AND FOR MECHANICAL EQUIPMENT REFER TO THEMECHANICAL SYSTEMS ABBREVIATIONS SCHEDULE.
SINGLE RECEPTACLE WALL / FLOOR / CEILING MOUNTED
DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED
DOUBLE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED
ABOVE COUNTER RECEPTACLE SINGLE / DUPLEX / DOUBLE DUPLEX.
SPLIT WIRE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED
SWITCH CONTROLLED DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED
SPECIAL PURPOSE RECEPTACLE WALL / FLOOR / CEILING MOUNTED
CLOCK RECEPTACLE WALL MOUNTED
JUNCTION BOX WALL / FLOOR / CEILING OR EQUIPMENT MOUNTED
POKE�THRU JUNCTION BOX
POWER POLE
DEDICATED CIRCUIT
ARROWHEAD INDICATES HOMERUN. X�1,3,5 ADJACENT TO HOMERUNARROWHEADS INDICATES HOMERUN TO PANEL X, CIRCUIT NUMBERS 1,3, AND 5.
INDICATES CIRCUIT CONTINUATION OF PANEL X CIRCUITS 3 AND 5
RACEWAY INSTALLED CONCEALED IN WALL AND/OR ABOVE CEILING
RACEWAY INSTALLED CONCEALED IN SLAB OR BELOW GRADE
RACEWAY INSTALLED EXPOSED
GROUND
FLEXIBLE RACEWAY (6'�0" MAX LENGTH)
CONDUIT UP / CONDUIT DOWN
CONDUIT TERMINATION (STUB�OUT)
CONDUIT CONTINUATION
BUS DUCT (SIZE/RATING AS NOTED)
MULTIPLE RACEWAY
CABLE TRAY
CABLE TRAY ELBOW AND 'T' CONNECTORS
HANDHOLE
MANHOLE
FLUORESCENT LIGHT FIXTURE. OVERHEAD / WALL MOUNTED
FLUORESCENT STRIP OR INDUSTRIAL LIGHT FIXTURE
LIGHT FIXTURE CEILING MOUNTED
LIGHT FIXTURE WALL MOUNTED
DIRECTIONAL OR WALL WASH LIGHT FIXTURE
EXIT SIGN INTERNALLY ILLUMINATED CEILING / WALL MOUNTED.PROVIDE ARROWS AS INDICATED.
EGRESS AND/OR EMERGENCY LIGHT FIXTURE
EGRESS AND/OF EMERGENCY LIGHT FIXTURE, HALF OF LAMPS OR CENTER LAMPON EMERGENCY CIRCUIT.
TRACK LIGHT HEADS AND TRACK
STEP LIGHT
LANDSCAPE UPLIGHT FIXTURE
BOLLARD FIXTURE AND BASE
SINGLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE
DOUBLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE
QUADRUPLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE
LIGHT FIXTURE WITH BATTERY BACKUP GRID, RECESSED, OR SURFACE MOUNT
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM MANUAL INITIATING STATION
FIRE ALARM AUDIO NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED
FIRE ALARM AUDIO AND VISUAL NOTIFICATION APPLIANCE, WALL / CEILINGMOUNTED
FIRE ALARM VISUAL NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED
FIRE ALARM MINI HORN, WALL / CEILING MOUNTED.
FIRE ALARM BELL, WALL MOUNTED
INDICATES CANDELA INTENSITY, DECIBEL RATING AND ZONE OF FIRE ALARMANNUCIATION DEVICES.
SMOKE DETECTOR, WALL / CEILING MOUNTED
HEAT DETECTOR, WALL / CEILING MOUNTED
CARBON MONOXIDE DETECTOR, WALL / CEILING MOUNTED
DUCT DETECTOR
MAGNETIC DOOR HOLDER AND RELEASE, WALL / HARDWARE MOUNTED
COMBINATION SMOKE DETECTOR AND MAGNETIC DOOR HOLDER ANDRELEASE
FIRE COMMUNICATIONS TELEPHONE JACK
FLUSH MOUNTED PANELBOARD
SURFACE MOUNTED PANELBOARD
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
80" / �
80" / �
80" / �
18" / � / �
18" / � / �
18" / � / �
ARCHITECT
18" / � / �
18" / � / �
18" / � / �
48"
80" / �
80" / �
80" / �
80" / �
48"
ALTERNATING CURRENTAC
NOTES
L�9
L�10,11
L�10,11
L�9
L�1,7,8
L�1,7,8
L�7
L�5
SYMBOL LEGEND NOTES
GENERAL NOTES
NON�FUSIBLE DISCONNECT SWITCH.RATING / POLES / NEMA ENCLOSURE
FUSIBLE DISCONNECT SWITCH.RATING / POLES / NEMA ENCLOSURE / FUSE RATING
MAGNETIC MOTOR STARTER.NEMA SIZE RATING / NEMA ENCLOSURE
COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECTING MEANS.NEMA SIZE RATING / NEMA ENCLOSURE / FUSE RATING (WHERE REQUIRED)
VARIABLE SPEED SOLID STATE STARTER AND DISCONNECTING MEANS.NEMA SIZE RATING / NEMA ENCLOSURE
EQUIPMENT AS INDICATED
TIME CLOCK
CONTACTOR
VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER
TELEVISION OUTLET, WALL / FLOOR / CEILING MOUNTED
TELECOMMUNICATIONS BACKBOARD.
LOW VOLTAGE PUSH BUTTON
AMMETER
VOLTMETER
DOOR CHIME
18" / � / �
18" / � / �
18"
48"
L�6
L�4
L�1 EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL BRANCH CIRCUIT RACEWAYS.
L�2 UNLESS NOTED, MOUNTING HEIGHT DIMENSIONS ARE TO THE CENTER OF THE DEVICE OR OUTLETABOVE FINISHED GRADE OR FINISHED FLOOR.
L�3 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST TELEPHONE BACKBOARD, UNLESS OTHERWISEINDICATED OR SPECIFIED.
L�4 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST DATA SYSTEM BACKBOARD
L�5 SPECIAL PURPOSE RECEPTACLE OUTLET, REFER TO KEYNOTES ON RESPECTIVE DRAWING FORDESCRIPTION.
L�6 TELEPHONE BACKBOARD TO BE PLYWOOD PAINTED WITH LOW SMOKE RELEASE PAINT. PROVIDE GROUNDCONDUCTOR AND DOUBLE DUPLEX RECEPTACLE. REFER TO SPECIFICATIONS.
L�7 DEDICATED CIRCUITS SHALL NOT SHARE A COMMON GROUND OR NEUTRAL CONDUCTOR WITH NON�DEDICATED CIRCUITS. DEDICATED CIRCUITS SHALL BE INSTALLED IN INDIVIDUAL RACEWAY SYSTEMS.DEDICATED CIRCUIT HOMERUNS SHALL NOT BE COMBINED TO SHARE NEUTRAL OR GROUND CONDUCTORS.
L�8 NON�DEDICATED BRANCH CIRCUITS SHALL CONSIST OF ONE PHASE CONDUCTOR, ONE NEUTRALCONDUCTOR AND ONE GROUND CONDUCTOR. SINGLE PHASE HOMERUNS MAY BE COMBINEDINTO THREE PHASE (a,b,c) 5�wIRE HOMERUNS AT THE DISCRETION OF THE CONTRACTOR.
L�9 MOUNTING HEIGHT DIMENSIONS ARE TO THE BOTTOM OF THE DEVICE ABOVE FINISHED GRADE OR FINISHEDFLOOR.
L�10 MOUNTING HEIGHT FOR THE BOTTOM OF THE AUDIBLE/VISUAL AND VISUAL DEVICE LENS SHALL BE80" ABOVE FINISHED GRADE OR FINISHED FLOOR.
L�11 VISUAL DEVICES LOCATED IN SLEEPING AREAS AND MOUNTED WITHIN 24" OF THE CEILING SHALL BE 177CD.
MTG. HT.NOTES 1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
COORDINATION NOTES
REVIEW ALL SPECIFICATIONS AND DOCUMENTS FOR ELECTRICAL REQUIREMENTS AND LOCATION OF EQUIPMENTREQUIRING ELECTRICAL SERVICE. PROVIDE SERVICE TO AND MAKE CONNECTIONS TO ALL SUCH EQUIPMENT.
REFER TO MECHANICAL AND PLUMBING DOCUMENTS FOR ALL MECHANICAL AND PLUMBING EQUIPMENT POWERREQUIREMENTS. PROVIDE QUANTITY OF BRANCH CIRCUITS, SWITCHES, DISCONNECTS, STARTERS, ETC., FOREQUIPMENT AS REQUIRED.
REFER TO FIRE PROTECTION DRAWINGS FOR ALL DEVICE REQUIRING ELECTRIC SERVICE AND/OR FIRE ALARMINTERFACE. PROVIDE CONNECTIONS AS REQUIRED.
1.
2.
3.
*
/
/
/
//
//
//
//
//
//
//
//
(DED)
PP
ZONE
60A/3/3R/40A
SIZE 2/3R
SIZE 2/3R/40A
60A/3/3R
A
V
SIZE 2/1
H
1�1
H H
9090
F
M
DBCD
M
F
FACP
F
HH
MH
X�1,3,5
3,5
TV TV
F
C
TC
CO CO
OU
OI
OD
OU
OI
OD
FAAP
TV
MOTOR
3
PP
S S
THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OFELECTRICAL EQUIPMENT. REVIEW ARCHITECTURAL DRAWINGS FOR DOOR SWINGS, CABINETS,COUNTERS, AND BUILT�IN EQUIPMENT; CONDITIONS INDICATED ON ARCHITECTURAL PLANS SHALLGOVERN. COORDINATE INSTALLATION OF ELECTRICAL EQUIPMENT WITH STRUCTURAL SYSTEM ANDMECHANICAL EQUIPMENT AND ACCESS THERETO. COORDINATE INSTALLATION OF RECESS ELECTRICALEQUIPMENT WITH CONCEALED DUCTWORK AND PIPING. REFER TO ARCHITECTURAL DRAWINGSAND/OR INTERIOR DESIGN DRAWINGS FOR ALL DIMENSIONS AND STANDARD DETAILS. DO NOT SCALE.
CAPITAL LETTERS BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. WHERE INDICATED ON DRAWINGSLOWER CASE LETTER INDICATES SWITCH LEG, DIMMER OR CONTROL DESIGNATION.
NUMERAL BESIDE EQUIPMENT, DEVICE, OR OUTLETS INDICATES CIRCUIT CONNECTION.
WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR ANDCONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT UNLESS OTHERWISE INDICATED.
EXTEND THREE (3) EMPTY 1" CONDUITS FROM EACH FLUSH MOUNTED PANEL TO POSITION ABOVEACCESSIBLE CEILING, IF APPLICABLE.
PROVIDE OUTLET BOX FITTING FOR EACH DEVICE, SIZE TO ACCOMMODATE DEVICE AND CONDUCTORS.
WALL SWITCHES CONTROLLING 277 VAC CIRCUIT OF OPPOSITE PHASES (OR 120VAC) SHALL NOT BE INSTALLEDIN A COMMON BOX UNLESS A PERMANENT BARRIER IS PROVIDED.
ALL CONDUITS PENETRATING ROOF SHALL BE SEALED. SEE ARCHITECTURAL DOCUMENTS AND DETAILS.
ALL RACEWAY AND EQUIPMENT SUPPORTS AND HANGERS SHALL BE ATTACHED TO STRUCTURAL MEMBERS.COORDINATE WITH STRUCTURAL DOCUMENTS.
DISCONNECT SWITCHES, MOTOR STARTERS, AND OTHER ELECTRICAL EQUIPMENT INSTALLED ABOVEACCESSIBLE CEILINGS AND REQUIRING ACCESS FOR MAINTENANCE, SHALL BE INSTALLED WITHBOTTOM OF DEVICE A MAXIMUM OF ONE (1) FOOT ABOVE CEILING TO PROVIDE READY ACCESSIBILITY.CODE AND MANUFACTURER REQUIRED CLEARANCES SHALL BE MAINTAINED.
ACCESS PANELS SHALL BE CONSOLIDATED TO MINIMIZE THE QUANTITY REQUIRED. COORDINATELOCATION WITH ARCHITECTURAL DOCUMENTS. THE PROPOSED LOCATION OF ACCESS PANELS SHALL BESUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION.
ALL CIRCUIT SHALL BE 2#12,1#12G,3/4"C UNLESS NOTED OTHERWISE.
PRIOR TO THE PANELBOARD ORDERING PROCESS, CONTRACTOR SHALL OBTAIN THE ACTUAL MAXIMUMAVAILABLE FAULT CURRENT DATA FROM THE UTILITY COMPANY AND PROVIDE FAULT CURRENT ANALYSISFOR THE FACILITY ELECTRICAL SYSTEM. AIC RATING FOR SWITCHBOARD AND PANELBOARD SHALL BEREVISED TO BE ABLE TO SUSTAIN THE FAULT CURRENT FOUND BY THE FAULT CURRENT ANALYSIS.
SERIES RATED PANELBOARDS AND BREAKERS ARE PROHIBITED.
PROVIDE STARTERS AND DISCONNECTS FOR ALL MECHANICAL AND PLUMBING MOTORS AND EQUIPMENTWITH MOTORS, UNLESS STARTERS ARE PROVIDED BY MANUFACTURER OF EQUIPMENT. SIZE ALL STARTERSAND DISCONNECTS PER THE NATIONAL ELECTRICAL CODE.
ALL SYMBOLS INDICATED IN LEGEND(S) MAY NOT NECESSARILY BE USED ON THIS PROJECT.
WEATHER RESISTANTWR
GRAPHICS LEGEND
DESCRIPTION
CUT LINE
SHEET NUMBER
SHEET NUMBER
REVISION AREA
REVISION DELTA
DRAWING NUMBER
DRAWING NUMBER
COLUMN REFERENCE GRID
SYMBOL
E1.2
E1.2
1
1 DRAWING TITLE
SCALE:
#
#
AREA TO BEDETAILED
KEYNOTEX
17. FIRE ALARM SYSTEM DRAWINGS AND SPECIFICATIONS SHOW THE MINIMUM REQUIREMENTS; ANY OTHERDEVICES REQUIRED MUST BE PART OF THE GENERAL CONTRACTOR'S BID NECESSARY TO BRING THE SYSTEMTO LOCAL CODE REQUIREMENTS.
18. CREATE AND SUBMIT FIRE ALARM SHOP DRAWINGS TO LOCAL AUTHORITY FOR APPROVAL.
19. ALL LOW VOLTAGE SYSTEMS TO BE BY OWNER'S VENDOR. CONDUIT AND BOXES BY CONTRACTOR.
18" / � / �L�3MULTI VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER
20. ALL 90 BATTERY BALLASTS USED FOR EMERGENCY/EGRESS LIGHTING SHALL PROVIDE A MINIMUM OF 700 LUMENSPER FIXTURE.
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 2014�008
CHECKED BY: RKC
DATE: 07/16/2014
REVISIONS
DATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
404�4
34�9
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
AL
BE
RT
DE
SIG
NG
RO
UP
,LL
CP
rim
rose
Sch
ools
R
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E�0
LEGENDS, NOTES ANDABBREVIATIONS
Electrical Sheet List
Sheet Number Sheet Name
E�0 LEGENDS, NOTES AND ABBREVIATIONS
E�2 FLOOR PLAN � LIGHTING
E�3 FLOOR PLAN � POWER
E�4 RISER DIAGRAMS
E�5 SCHEDULES AND DETAILS
E�6 SPECIFICATIONS
12 CUBBIES
PU
T D
OW
N
WA
LL
CA
B.
WA
LL
CA
B.
SH
EL
F
TR
AN
SP
OR
T S
TG
.
WA
LL
CA
B.
16 CUBBIES
SH
EL
F
TR
AN
SP
OR
T S
TG
.
WA
LL
CA
B.
PU
T D
OW
N C
OU
NT
ER
SH
EL
FS
HE
LF
SHELF SHELF
14 CUBBIES16 CUBBIES
SH
EL
F
48" WALL CAB.48" WALL CAB.
SHELF
SH
EL
F
LA
TE
RA
LL
AT
ER
AL
DW
R
DWR
DWR
DW
R
8 CUBBIES 8 CUBBIES
FR
EE
ZE
RR
EF
RIG
.
8 CUBBIES
PU
T D
OW
N C
OU
NT
ER
8 CUBBIES
48
" WA
LL
CA
B.
36" WALL CAB. 36" WALL CAB.
3a 3b 3b 3a
OCOC
OC
OC
OC
OC
OC
OC
OC
OC OC
OC
OC
OC
OC
OC
3a 3b
OC
D D
3a3b3a3b
3a3b
OC
OC
3a3b
3b3a
OC
OC
OC
D
OC
3/OC
DR
3/OC
OC
A a
A b
AA
A b
A aA a
AX
A
A
A
AX a
A b
A a
A a
AX b
A b
A a
A
A a AX b A a
A b A a A b
A a AX b A a
A bA a
AX b A aA a
A b
A b A b
AX a
A b
A a
A aA bA a
A b
A aA bA a
A b AX a
A a AX b A a
RX
R
R
R
A a AX b
A b A a A b
A AX
R
R
D
D
DX
D
D DX
D D DX D
D DX D D
D
DX D
D
DX
D
D D D
DX D
D D
D
A
AX
X1
X1
CX
AX b
A a A b
D
D
D
DX
D DX D DX D DX D
DX D
CX
D
DX
CX
CX
AX aA b
A a
A b A a A b A a
CX
CX
CX
CX
ACX
DDXDDXDDXDDX
CX
CX
CX
CX
X1
X1
X1
X1
X1
X1 X1
X1
X1
X1
P1
P1
P1
P1
P1
SX
SX
SX SXSX
SX
A b
A a
B ! 49
B ! 51
B ! 51B ! 47
B ! 53
B ! 54
B ! 53
B ! 54
B ! 52
B ! 56
B ! 49
B ! 50
X1
X1JJ
B ! 6 B ! 7
2
1
(TYP. OF 4)
bcd
N
N
B ! 48
CX
B ! 55
a b
a b a b
a b
b a b a
a b
b a
ab
ba
a b
ab
a b
SX
a b
B ! 49
CLASSROOM C1 CLASSROOM C2
CLASSROOM D2CLASSROOM D1
TOILET #13
TOILET #10
TLT #12
TLT #11
STORAGE
TOILET #8
TOILET #9
GALLERY #2
CAR SEATSTORAGE
VESTIBULE
RECEPTION
OFFICE
TLT #2 WOMEN'S
TLT #1 MEN'S
CONF.
CLASSROOM EP1
WARMINGKITCHEN
CLASSROOM A2CLASSROOM A2CLASSROOM B1
CLASSROOM EP2CLASSROOM EP3
TOILET #4
TOILET #5
RESOURCE
STAFF
TOILET #7
TOILET #6
TOILET #3
LAUNDRY
GALLERY #1
GA
LLE
RY
#3
GA
LLE
RY
#4
XN XNXN
XN
XN
XN XNXN XNXN XNXN XNXNXN
XNXN
XP
XN
XP XP
XNXN
XT
XP
XN
XPXPXP
XN
XN
B ! 57
a b
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 2014!008
CHECKED BY: RKC
DATE: 07/16/2014
REVISIONS
DATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
404!4
34!9
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
AL
BE
RT
DE
SIG
NG
RO
UP
,LL
CP
rim
rose
Sch
ools
R
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E!2
FLOOR PLAN ! LIGHTING
1/8" = 1'!0"E!2
1 FLOOR PLAN ! 1ST FLOOR ELECTRICAL LIGHTING
KEYNOTES: X
SHEETNOTES:1 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES.
2 REFER TO DRAWING E!0 FOR LIGHTING FIXTURE SCHEDULES.
3 REFER TO DRAWING E!5 FOR PANELBOARD SCHEDULES.
4 ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE PROVIDED WITH 90 MINUTE BATTERYBACKUP. LIGHTING FIXTURE IDENTIFICATIONS THAT END WITH "X" ARE EMERGENCY LIGHTINGFIXTURE TYPE. CIRCUIT BATTERY BALLAST AND EXIT SIGNS TO UNSWITCHED PORTION OF CIRCUITINDICATED.
5 ALL EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES SHALL BE CONNECTED TO THE SAME CIRCUITAS THE NORMAL LIGHT FOR THE AREA OF ROOM BEING SERVED. PROVIDE CONNECTION TOUNSWITCHED PORTION OF CIRUIT FOR VOLTAGE SENSING AND BATTERY CHARGING. PROVIDE FAILSAFE RELAY SO AS IN THE EVENT OF NORMAL POWER LOSS OR EMERGENCY SITUATION, LIGHT WILLBE TURNED ON REGARDLESS OF CONTROL SWITCH POSITION.
6 ALL EXTERIOR LIGHTING SHALL BE AUTOMATICALLY CONTROLLED VIA TIME CLOCK/PHOTOCELL ORTHROUGH LIGHTING CONTROL PANEL SPECIFIED BY LIGHTING DESIGNER.
7 ALL INTERIOR LIGHTING CIRCUITS SHALL BE ROUTED THROUGH RELAY PANEL XXX. REFER TO POWERPLANS FOR LOCATION.
8 EXISTING EXTERIOR DOWNLIGHTS TO REMAIN. EC SHALL VERIFY FIXTURE IS IN WORKING ORDER,REPLACE AS REQUIRED. CLEAN AND RELAMP FIXTURES. CONNECT TO SWITCH "b" LOCATED INOFFICE FOR CONTROLS.
9 EXISTING PARKING POLE LIGHTING TO REMAIN. PROVIDE 3 CIRCUITS A!58,59 AND 60.
1 OFFICE LIGHTS SHALL BE AS FOLLOWS: SWITCH "b" IF FOR OUTSIDE LIGHTOVERRIDE, SWITCH "c" IS FOR SIGN AND EMBLEM OVERRIDE, SWITCH "d" IS FOR LOTLIGHTS OVERRIDE. PERMENANTLY LABEL SWITCHES.
2 LIGHTING FOR WARMING KITCHEN NEEDS TO BE GASKETED.
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION LAMP WATTAGE VOLTAGE MOUNTING TYPE COMMENTS
A 2' X 4', RECESSED VOLUMETRIC FLUORESCENT, T5 LAMPS,ELECTRONIC BALLAST
(2) FP28 3500K 96W 120 V GRIDRECESSED
AX 2' X 4', RECESSED VOLUMETRIC FLUORESCENT, T5 LAMPS,ELECTRONIC BALLAST. 90 MINUTE EMERGENCY BALLAST.
(2) FP28 3500K 56W 120 V GRIDRECESSED
CX RECESSED NOM 1'X1' VOLUMETRIC CFL, ELECTRONIC BALLASTWITH EMERGENCY BALLAST.
(1) 32w TRT 3500 32W 120 V RECESSEDLAY!IN ORDRYWALL
D 6" (NOM.) SQUARE RECESSED CFL DOWNLIGHT, CLEARREFLECTOR, SELF!FLANGED, CONCENTRIC LENS
(1) 32TRT 3500K 32W 120 V RECESSED
DX 6" (NOM.) SQUARE RECESSED CFL DOWNLIGHT, CLEARREFLECTOR, SELF!FLANGED, CONCENTRIC LENS. 90 MINUTEEMERGENCY BALLAST.
(1) 32TRT 3500K 32W 120 V RECESSED
J 4' UNDERCABINET LIGHT (1) FP28/835 28W 120 V UNDERCABINET
N 6" RECESSED COMPACT FLUORESCENT DOWNLIGHT, CLEARREFLECTOR
(1) 26DTT 26 W 120 V RECESSED
P1 3" DIA. PENDANT, HARVEST WHITE, LINEN BOTTOM. (4) CF 26TT/835 104W 120 V PENDANTCEILING
POLELIGHTS
R 4' SURFACE MOUNTED WRAPAROUND FLUORESCENT, T5LAMPS, ELECTRONIC BALLAST.
(4) FP28/835 112W 120 V SURFACE
RE 4' SURFACE MOUNTED WRAPAROUND FLUORESCENT, T5LAMPS, ELECTRONIC BALLAST. 90 MINUTE EMERGENCYBALLAST.
(4) FP28/835 112W 120 V SURFACE
SX SCONCE EXIT DISCHARGE REMOTE EMERGE. 90 MINUTEEMERGENCY BALLAST.
42W CF 42W 120 V SURFACE EXTERIOR WALL MOUNTEDSCONCE WITH 90 MINUTEBATTERY BALLAST.
X1 SELF CONTAINED EMERGENCY LIGHT FIXTURE, EDGE LIT TYPE,SINGLE FACE (X2 DOUBLE FACE).
LED 5W 120 V SURFACE
XN EXISTING COMPACT FLUORESCENT DOWNLIGHT TO REMAIN. (1) 26DTT 26 W 120 V RECESSED
XP EXISTING SURFACE MOUNTED EXTERIOR FIXTURE. (1) CF 26TT/835 26W 120 V SURFACE
XT EXISTING 2 HEAD, DAMP LOCATION EMERGENCY FIXTURES. W/UNIT 22W 120 V SURFACE
0' 1' 4' 8' 16'
SCALE: 1/8" = 1'�0"
N
x;F
RE
EZ
ER
x;R
EF
RIG
.
12 CUBBIES
PU
T D
OW
N
WA
LL
CA
B.
WA
LL
CA
B.
SH
EL
F
TR
AN
SP
OR
T S
TG
.
WA
LL
CA
B.
16 CUBBIES
SH
EL
F
TR
AN
SP
OR
T S
TG
.
WA
LL
CA
B.
PU
T D
OW
N C
OU
NT
ER
SH
EL
FS
HE
LF
SHELF SHELF
14 CUBBIES16 CUBBIES
SH
EL
F
48" WALL CAB.48" WALL CAB.
SHELF
SH
EL
F
LA
TE
RA
LL
AT
ER
AL
DW
R
DWR
DWR
DW
R
8 CUBBIES 8 CUBBIES
F
F F
IC
IC
F
TV
J
J
FF
GF G
F
F F
F
F
GF
DC DC DC DC
DB
DC
DC
DC
DC
IC
IC
DB
IC
IMIC
IC
IC
IC
IC
ICF
JJ
J
GF
F
C TC
GF
GF
GF
GF
GF
GF
GF GF
GF
B
A
GF
GF
GF
.
1
2
3
4
5
6 7
8
9
10
11
1312
B & 46
B & 8
B & 2
B & 5
B & 6B & 7
B & 10
B & 42
B & 22
B & 24
B & 23
B & 16
B & 15B & 13
B & 26
B & 12B & 29
GFGF
B & 27
FACP
SECURITY
B & 31
B & 33
B & 35
B & 14
B & 19 B & 45
2
B & 37B & 39
14
15
16
17
B & 4
GFGF
B & 3
GF
GF
B & 40
GF18
B & 41,43
B & 30,32
B & 11
B & 18
B & 17
B & 21
B & 28
B & 20
B & 45
B & 9
B & 34,36
A & 32,34,36
WH&1
A & 38,40,42
WH&2
21 2421 24
21 24
21 24
24
19 20
CLASSROOM C1 CLASSROOM C2
CLASSROOM D2CLASSROOM D1
TOILET #13
TOILET #10
TLT #12
TLT #11
STORAGE
TOILET #8
TOILET #9
GALLERY #2
CAR SEATSTORAGEVESTIBULE
RECEPTION
TLT #2WOMEN'S
TLT #1 MEN'S
CLASSROOM EP1
WARMINGKITCHEN
CLASSROOM A2
CLASSROOM A2CLASSROOM B1
CLASSROOM EP2CLASSROOM EP3
TOILET #4
TOILET #5
RESOURCE
STAFF
TOILET #7
TOILET #6
TOILET #3
LAUNDRY
GALLERY #1
GA
LLE
RY
#3
OFFICE24
24
METER ANDCT CABINET
A & 14,16,18
CU&3A & 8,10,12
CU&2
A & 31,33,35
CU&7
A & 2,4,6
CU&1
A & 26,28,30
CU&6
A & 19,21,23
CU&5A
A & 20,22,24
CU&4
A & 15
FCU&7
A & 13
FCU&6
A & 9
FCU&5A
A & 7
FCU&4A & 5
FCU&3
A & 1
FCU&1
A & 3
FCU&2
B & 48
EF&18
B & 48
EF&1B & 49
EF&15
B & 49
EF&14
B & 51
EF&2
B & 51
EF&16
B & 51
EF&17
B & 51
EF&3
B & 52
TEF&B
B & 52
EF&4
B & 52
EF&5
B & 47
EF&12
B & 47
TEF&A
B & 50
EF&19
A & 25,27,29
CU&5B
A & 11
FCU&5B
B & 1
B & 53
EF&6
B & 53
EF&7
B & 54
EF&8
B & 54
EF&11B & 54
EF&10
B & 54
EF&9
GF
GF
GF
GF 4
4
4
FLUSHMOUNTED
SWITCH LOCATED AT TV CABINET
OFFICE
2 COMPUTERS
1 PRINTER
(5)
C&1
2 COMPUTERS
1 PRINTER
(8)
1 PDA
C&2
2 COMPUTERS
1 PRINTER
(5)
D&2
4 COMPUTERS
1 PRINTER
(8)
1 PDA
D&1
4 COMPUTERS
1 PRINTER
(8)
CONFERENCE
OFFICE PRINTER
OFFICE
RECEPTION
RECEPTION
(16)
CABLES FURNISHED ANDINSTALLED BY OWNER &TYP.
WIRE FURNISHED AND INSTALLEDBU CONTRACTOR WITH 6' MIN.SLACK. TERMINATIONSBYOWNER & TYP.
4
22
20
4
TYP.
24
TYP.
STAFF
RESOURCE
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 2014&008
CHECKED BY: RKC
DATE: 07/16/2014
REVISIONS
DATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
404&4
34&9
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
AL
BE
RT
DE
SIG
NG
RO
UP
,LL
CP
rim
rose
Sch
ools
R
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E&3
FLOOR PLAN & POWER
1/8" = 1'&0"E&3
1 FLOOR PLAN & 1ST FLOOR& ELECTRICAL POWER
KEYNOTES: XSHEETNOTES:
1 DEVICE LOCATIONS SHOWN ON THE PLAN SHALL BE PLACED EXACTLY AS SHOWN.COORDINATE WITH INT. ELEVATIONS SHEETS.
2 ALL ELECTRIC OUTLETS IN CLASSROOMS AND HALLWAYS SHALL BE INSTALLED 18"AFF TO TOP OF OUTLET ABOCE FLOOR UNLESS NOTED OTHERWISE.
3 ALL FIXTURES, WIRE AND ELECTRIC DEVICES SHALL BE U.L. APPROVED TYPE.
4 ALL OUTSIDE OUTLETS SHALL BE GROUND FAULT TYPE WITH WEATHER PROOFCOVER, MOUNT AT 24" A.F.G. UNLESS NOTED OTHERWISE.
5 ALARM PANEL AUTOMATIC CALL TYPE TO MEET NFPA 72&CURRENT EDITION.
6 ALL EMERGENCY ALARMS SHALL BE IN COMPLIANCE WITH MIN. DESIGN OF STYLEB.&NFPA 72&CURRENT EDITION.
7 MOUNT NON&FUSIBLE DISCONNECT SWITCH FOR CONDENSING UNITS AT 24" A.F.F.
8 ALL VISUAL AND AUDIO ALARMS SHALL COMPLY WITH SECTION 4.28, "ALARMS" OFTHE FEDERAL ADAAG.
9 ALL FGCI RECEPTACLES SHALL BE READILY ACCESSIBLE AND NOT INSTALLEDBEHIND EQUIPMENT OR APPLIANCES. COORDINATE WITH THE OWNER PRIOR TOINSTALLATION TO INSURE ACCESSIBILITY.
10 ALL RECEPTACLES IN CLASSROOM AREAS SHALL BE TAMPERPROOF TYPE.
1 WATER FOUNTAIN
2 PROVIDE CHIME AND TRANSFORMER FOR DOORBELL (NILES DB12).CIRCUIT TO A&5 USING 2#12,1#12G,3/4"C.
3 DOOR BELL PUSH BUTTON
4 NETWORK SWITCH & 5, 8, OR 16 PORT AS NOTED (UFOI) MOUNT TOCONCEALED UNDER DESK.
5 COPIER, PROVIDE 120V DEDICATED CIRCUIT, 2#12,1#12, 3/4"C
6 WASHER, PROVIDE 208V DEDICATED CIRCUIT, 2#12,1#12G, 3/4"C
7 DRYER, PROVIDE 208V, 30A, 2#10,1#10G,3/4"C
8 REFRIGERATOR, 120V, 2#12,1#12G, 3/4"C
9 FREEZER, 120V, 2#12,1#12G, 3/4"C
10 MICROWAVE, 208V, 30A, 2#10,1#10G,3/4"C
11 ICE MAKER, 120V, 2#12,1#12G, 3/4"C
12 SPRINKLER CONDENSER
13 IRRIGATION CONTROLS
14 PROVIDE CONDUIT BETWEEN J&BOX AT TV AREA IN LOBBY ANDRECEPTION DESK.
15 CONNECTION TO "G" LED TAPE LIGHT.
16 INTERCOM STATION @ 48" A.F.F.
17 INTERCOM MASTER STATION @ 48" A.F.F.
18 CONVECTION OVEN
19 PROVIDE JUNCTION BOX FOR CABLE TV @42" AFF. RUN 3/2" CONDUITWITH PULL STRING ABOVE CEILING.
20 WIRELESS ROUTER (OFOI). PROVIDE 2" CONDUIT ABOVE CEILING WITHCABLE OR CAT5 OR 6 WIRE PER OWNER'S INTERNET PROVIDERS POINTOF ENTRY. TERMINATE WITH 2" ELBOW AT 72" AFF BEHIND TV CABINET.PROVIDE DUPLEX OUTLET.
21 POA (UFOI) IN UPPER CABINET. PROVIDE DUPLEX OUTLET ANDNETWORK/JACK FACEPLATE WITH CAT5 OR 6 WIRE IN 3/4" CONDUIT TOABOVE CEILING&RUN TO SWITCH.
22 POINT OF ENTRY FOR CABLE OR PHONE (DSL). VERIFY EXACTLOCATION IN FIELD.
23 ALTERNATE POINT OF ENTRY FOR CABLE OR PHONE (DSL). (NOTINDICATED ON DRAWING. VERIFY IN FIELD).
24 NETWORK FACEPLATE AT 18" AFFF WITH HOLE(S) FOR CT5 OR 6 WIRE.RUN 3/4" CONDUIT TO ABOVE CEILING INSTALLATION. PROVIDE WIRE TOPOINT DESIGNATED ON PLAN. LEAVE MINIMUM 6' SLACK BOTH ENDS.END CONNECTIONS O.F.O.I. RUN ALL WIRE IN NEAT MANNER. DO NOTBLOCK ANY WALKWAYS OR PATHS.
N.T.S.E&3
2 NETWORK SCHEMATIC WIRING DIAGRAM
N
0' 1' 4' 8' 16'
SCALE: 1/8" = 1'�0"
TGRADE
4#600KCMIL IN 4"C, TYPE XHHW
CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALLPOWER DISTRIBUTION BLOCKS, OVERSIZED LUGS, ADDITIONALWIRE BENDING SPACE IN PANELBOARD ENCLOSURES, ETCREQUIRED TO TERMINATE THE ELECTRICAL FEEDERS TOELECTRICAL EQUIPMENT AS SHOWN AND FALLS UNDERCONTRACTOR MEANS AND METHODS. INSTALLATION SHALLBE UL LISTED, APPROVED BY THE DISTRIBUTION EQUIPMENTMANUFACTURER AND THE AUTHORITY HAVING JURISDICTION.
REFER TO 3/E%5 FORMORE INF0RMATION
EXISTING UTILITYTRANSFORMERTO REMAIN.COORDINATE REQUIREMENTSWITH UTILITY.PANEL A
208Y/120V400A BUS
4#600KCMIL, 1#2G, 4"C, TYPEXHHW
400A
1%1/2"C
CT CABINET
4#3/0,1#6G,2"C
PANEL B208/120V250A BUS
TAMPER SWITCHES ATBACK FLOW PREVENTER.REFER TO FP DRAWINGSFOR EXACT LOCATION.
FACP
NOTE:
REFER TO GENERAL NOTES 17 & 18 ON SHEET E%0
FOR ADDITIONAL FIRE ALARM REQUIREMENTS.
F F F
FFF
T F
TT
F
SEE POWER PLAN FOR QUANTITY AND LOCATION DEVICES.
1.
2.
NOT ALL DEVICES SHOWN FOR CLARITY.3.
ALARM
TROUBLE
ALARM
TROUBLE
ALARM
TROUBLE
TROUBLE
ALARM
ALARM
TROUBLE
TROUBLE
ALARM
AU
DIB
LE
AN
D V
ISU
AL
AL
AR
M (
PR
ER
EC
OR
DE
D V
OIC
E M
ES
SA
GE
, O
VE
RR
IDE
BA
CK
BR
OU
ND
MU
SIC
) A
ND
FIR
E D
EP
AR
TM
EN
T N
OT
IFIC
AT
ION
SU
PE
RV
ISO
RY
ALA
RM
AN
D L
IGH
T IN
FA
CP
AN
D C
EN
TR
AL S
TA
TIO
N N
OT
IFIC
AT
ION
.(O
VE
RR
IDE
AL
L B
AC
KG
RO
UN
D M
US
IC.)
DIS
PL
AY
ME
SS
AG
E A
T F
IRE
AL
AR
M A
NN
UN
CIA
TO
R P
AN
EL
TROUBLE
ALARM
TR
OU
BL
E A
LA
RM
AN
D L
IGH
T IN
FA
CP
FIRE ALARM OPERATING SEQUENCE SCHEDULE
UN
LO
CK
DO
OR
HIS
TO
RIC
AL
LO
G
FA
N S
HU
TD
OW
N
SPRINKLER TAMPER SWITCHES
FCU DUCT DETECTORS(SUPPLY AIR DUCT)
SPRINKLER ALARM PRESSURE SWITCHES
SPRINKLER WATER FLOW SWITCHES
FCU DUCT DETECTORS(RETURN AIR DUCT)
MANUAL PULL STATIONS
FAULT IN MONITORING CIRCUITOR COMPONENT
SMOKE DETECTORS
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 2014%008
CHECKED BY: RKC
DATE: 07/16/2014
REVISIONS
DATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
404%4
34%9
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
ALBERTDESIGNGROUP,LLC
Pri
mro
se S
choo
lsR
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E%4
RISER DIAGRAMS
N.T.S.E%4
1 ONE%LINE DIAGRAM
N.T.S.E%4
2 FIRE ALARM ONE%LINE DIAGRAM
N.T.S.E%4
3 FIRE ALARM SEQUENCE
3/0 COPPER
CONDUCTOR
ELECTRODE
FROM FOUNDATION LINE (MIN.)
GROUND ROD 3/4 " X 10'�0"TO BE 2'�0" AWAY
FINISHED GRADE
EXOTHERMICALLY WELDED
(MIN
)
5'�0
"
PROVIDE 1/4" X 5 7/8" X 12" BAR, DRILLEDAND TAPPED AS REQUIRED.INSULATORS SHALL BE 2.7kV RATED.
COPPER GROUND BUS
INSULATORS
STAND�OFFBRACKETS
1.
DETAIL NOTES:
TO INTERIOR PIPINGSYSTEMS (COLD WATERAS APPLICABLE)
GENERAL NOTES:
2. LENGTH OF GROUND RODS DEPENDENT ON GROUNDRESISTANCE REQUIRED AND/OR SPECIFICATIONS.MINIMUM GROUND ROD TO BE 3/4" X 10'.
1. ALL GROUNDING CONDUCTORS ARE 3/0 COPPERUNLESS NOTED OTHERWISE.
3. ALL GROUNDING CABLES SHALL BE MINMUM 3/0,EXCEPT WHERE REQUIRED TO BE INCREASED INSIZE BY NEC ARTICLE 250.
UL�APPROVEDCLAMP
COLD WATERSERVICEENTRANCE
SUPPLYVALVEMETER
OR UNION SIDE
THE DEPTH OF ELECTRODE.
SEE NOTE 2
GROUNDING ELECTRODESSPACING TO BE TWICE
JUMPER
GROUND BUS
NOTE 3
TO SWITCHBOARDENCLOSURE
CADWELD
BUILDINGSTRUC. STEEL
3/0 TYPICAL
FOUNDATIONREENFORCINGSTEEL
NEC 250�50(a)
METAL PIPEMEETING
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 2014�008CHECKED BY: RKC
DATE: 07/16/2014
REVISIONSDATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
404�4
34�9
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
AL
BE
RT
DE
SIG
NG
RO
UP
,LL
CP
rim
rose
Sch
ools
R
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E�5
SCHEDULES ANDDETAILS
N.T.S.E�51 GROUND ROD DETAIL
N.T.S.E�52 GROUNDING BAR
N.T.S.E�54 NEUTRAL GROUNDING SYSTEM
KITCHEN EQUIPMENT SCHEDULE
UNIT DESCRIPTION WATTS FLA VOLTS POLES PANEL DIRECT PLUG CIRCUIT NUMBER CIRCUIT DESCRIPTION NOTES
FREEZER REACH IN 2DOOR
864 W 7.2 A 120 V 1 B No Yes 33 2#12, 1#12G, 3/4"C MANUFACTURER TRUE FOOD SERVICE EQUIPMENT INC.,T�49F
ICE MAKER 1800 W 15.0 A 120 V 1 B No Yes 14 2#12, 1#12G, 3/4"C SCOTSMAN #CU0515
MICROWAVE 4400 W 22.5 A 208 V 2 B No Yes 30,32 2#10, 1#10G, 3/4"C THE AMANA #RC30S
FRIDGE REACH IN 2 DOOR 1656 W 13.8 A 120 V 1 B No Yes 31 2#12, 1#12G, 3/4"C MANUFACTURER TRUE FOOD SERVICE EQUIPMENT INC.,T�35
CONVECTION OVEN 5600 W 23.3 A 208 V 2 B No Yes 41,43 2#10, 1#10G, 3/4"C CADCO MODEL# XAF�193
EX � Existing circuit.
LK � Provide with lockable breaker.
AFCI � Provide with Arc Fault Circuit Interrupt breaker.
GFCI � Provide with Ground Fault Circuit breaker.Notes Legend:
Power 18116 VA 18116 VA
Other 0 VA 0 VA
Motor 1600 VA 1600 VA Total Est. Demand: 150 A
Equipment 500 VA 500 VA Total Conn.: 158 A
HVAC 340 VA 340 VA Total Est. Demand: 53889 VA
Receptacle 22980 VA 16490 VA Total Conn. Load: 57010 VA
Lighting 13474 VA 16843 VA
Load Classification Connected Load Estimated Demand Panel Totals
Total Amps: 178 A 139 A 165 A
Total Load: 20940 VA 16653 VA 19378 VA
�� 83 SPACE �� �� 0 0 �� �� SPACE 84 ��
�� 81 SPACE �� �� 0 0 �� �� SPACE 82 ��
�� 79 SPACE �� �� 0 0 �� �� SPACE 80 ��
�� 77 SPACE �� �� 0 0 �� �� SPACE 78 ��
�� 75 SPACE �� �� 0 0 �� �� SPACE 76 ��
�� 73 SPACE �� �� 0 0 �� �� SPACE 74 ��
�� 71 SPARE 20 1 0 0 1 20 SPARE 72 ��
�� 69 SPARE 20 1 0 0 1 20 SPARE 70 ��
�� 67 SPARE 20 1 0 0 1 20 SPARE 68 ��
�� 65 SPARE 20 1 0 0 1 20 SPARE 66 ��
�� 63 SPARE 20 1 0 0 1 20 SPARE 64 ��
�� 61 SPARE 20 1 0 0 1 20 SPARE 62 ��
59 EXIST POLE LIGHTS 20 1 1600 1600 1 20 EXIST POLE LIGHTS 60
57 LTG � EXISTING EXTERIOR 20 1 800 1600 1 20 EXIST POLE LIGHTS 58
55 LTG � SPRINKLER RM 20 1 32 1262 1 20 LTG � GALLARIED AND... 56
53 LTG � CLASSROOM C1�C2 20 1 955 1355 1 20 LTG � CLASSROOM D1�D2 54
51 LTG � CLASSROOMS EP1�EP2 20 1 778 1115 1 20 LTG � RECEPT, OFFICE,... 52
49 LTG � CLASSROOMS A2 20 1 1203 357 1 20 LTG � CLASSROOM EP3 50
47 LTG�CLASSROOM EP3 20 1 515 541 1 20 LTG � CLASSROOM B 48
45 RCPT�HALLWAY 20 1 900 360 1 20 RCPT�TOILET 46
�� 43 �� �� �� 2800 360 1 20 RCPT�VEST/CONF 44
41 CONVECTION OVEN 30 2 2800 1440 1 20 RCPT�CLASSROOM D2 42
39 RCPT�HALLWAY 20 1 540 360 1 20 RCPT�TOILET 40
37 SECURITY 20 1 300 1440 1 25 FIRE SMOKE DAMPER 38
35 FACP 20 1 500 600 �� �� �� 36 ��
33 FREEZER 20 1 1320 600 2 20 DRYER 34
31 REFRIGERATOR 20 1 1656 1500 �� �� �� 32 ��
29 RCPT�IRRIGATION... 20 1 180 1500 2 30 MICROWAVE 30
27 WASHER 20 1 1200 600 1 20 SPRINKLER COMPRESSOR 28
25 COPIER 20 1 300 1000 1 20 WATER FOUNTAIN 26
23 RCPT� CLASSROOM C2 20 1 1080 720 1 20 RCPT�CLASSROOM C2 24
21 RCPT� CLASSROOM D2 20 1 720 720 1 20 RCPT� CLASSROOM D2 22
19 RCPT�CLASSROOM A2 20 1 540 900 1 20 RCPT�LAUNDRY/EP3 20
17 RCPT� CLASSROM C1 20 1 900 720 1 20 RCPT� CLASSROOM C1 18
15 RCPT�RECEPTION 20 1 360 540 1 20 RCPT�RECEPTION 16
13 RCPT�OFFICE 20 1 900 2400 1 20 ICE MAKER 14
11 RCPT� WARMING KITCHEN 20 1 360 1080 1 20 RCPT�CLASSROOM D1 12
9 RCPT� CLASSROOM EP1 20 1 1080 1080 1 20 RCPT�... 10
7 RCPT� CLASSROOM A2 20 1 1110 1080 1 20 RCPT�HALLWAY 8
5 RCPT� CLASSROOM A2 20 1 180 750 1 20 RCPT�CLASSROOM A2 6
3 RCPT�RESOURCE/STAFF 20 1 1320 660 1 20 RCPT�HALLWAY 4
1 RCPT�CLASSROOM B1 20 1 900 900 1 20 RCPT� CLASSROOM EP3 2
Notes CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes
Enclosure: Type 1
Mounting: Recessed Wires: 4 Mains Rating: 200 A
Supply From: A Phases: 3 Mains Type: MLO
Location: Volts: 120/208 Wye A.I.C. Rating: 22000
Branch Panel: B
EX � Existing circuit.
LK � Provide with lockable breaker.
AFCI � Provide with Arch Fault Circuit Interrupt breaker.
GFCI � Provide with Ground Fault Circuit Interrupt breaker.
Notes Legend:
Receptacle 22980 VA 16490 VA
Power 48116 VA 48116 VA
Other 0 VA 0 VA
Motor 1600 VA 1600 VA Total Est. Demand: 382 A
Lighting 13474 VA 16843 VA Total Conn.: 391 A
HVAC 22444 VA 22444 VA Total Est. Demand: 137645 VA
Equipment 500 VA 500 VA Total Conn. Load: 140766 VA
Cooling 31652 VA 31652 VA
Load Classification Connected Load Estimated Demand Panel Totals
Total Amps: 412 A 374 A 385 A
Total Load: 49278 VA 44938 VA 46067 VA
�� 41 �� �� �� 19181 5000 �� �� �� 42 ��
�� 39 �� �� �� 16504 5000 �� �� �� 40 ��
37 PANEL B 200 3 20843 5000 3 100 WH�2 38
�� 35 �� �� �� 1788 5000 �� �� �� 36 ��
�� 33 �� �� �� 1788 5000 �� �� �� 34 ��
31 CU�7 30 3 1788 5000 3 100 WH�1 32
�� 29 �� �� �� 1315 1776 �� �� �� 30 ��
�� 27 �� �� �� 1315 1776 �� �� �� 28 ��
25 CU�5B 20 3 1315 1776 3 30 CU�6 26
�� 23 �� �� �� 1315 2016 �� �� �� 24 ��
�� 21 �� �� �� 1315 2016 �� �� �� 22 ��
19 CU�5A 20 3 1315 2016 3 35 CU�4 20
�� 17 SPARE 20 1 0 2016 �� �� �� 18 ��
15 FCU�7 20 1 1548 2016 �� �� �� 16 ��
13 FCU�6 20 1 1548 2016 3 35 CU�3 14
11 FCU�5B 20 1 1548 1776 �� �� �� 12 ��
9 FCU�5A 20 1 1548 1776 �� �� �� 10 ��
7 FCU�4 20 1 1548 1776 3 30 CU�2 8
5 FCU�3 20 1 1548 1788 �� �� �� 6 ��
3 FCU�2 20 1 1548 1788 �� �� �� 4 ��
1 FCU�1 20 1 1548 1788 3 30 CU�1 2
Notes CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes
Enclosure: Type 3R MCB Rating: 400 A 100% RATEDMounting: Surfaced Wires: 4 Mains Rating: 400 A
Supply From: Phases: 3 Mains Type: MCB
Location: Volts: 120/208 Wye A.I.C. Rating: 42000
Branch Panel: A
ELEC � PLUMBING EQUIPMENT SCHEDULE (NOT IN USE)
UNIT NUMBER UNIT DESCRIPTION W TOTAL VA FLA VOLTAGE POLES PANEL CIRCUIT NUMBER CIRCUIT DESCRIPTION DISCONNECT STARTER NOTES
WH�1 WATER HEATER 15000 W 15000 VA 62.1 A 208 V 3 A 32,34,36 4#4, 1#8G, 1�1/4"C 100/3/1 N/A
WH�2 WATER HEATER 15000 W 15000 VA 62.1 A 208 V 3 A 38,40,42 4#4, 1#8G, 1�1/4"C 100/3/1 N/A
ELEC + MECHANICAL EQUIPMENT SCHEDULE
UNIT NUMBER HEATER W HP TOTAL VA FLA VOLTAGE POLES PANEL CIRCUIT NUMBER CIRCUIT DESCRIPTION DISCONNECT STARTER NOTES
CU�1 5832 W 1/5 5364 VA 14.9 A 208 V 3 A 2,4,6 3#10,1#10G,3/4"C 30/3/3R W/UNIT
CU�2 5832 W 1/5 5328 VA 14.8 A 208 V 3 A 8,10,12 3#10,1#10G,3/4"C 30/3/3R W/UNIT
CU�3 6804 W 1/5 6048 VA 16.8 A 208 V 3 A 14,16,18 3#8,1#10G,3/4"C 60/3/3R W/UNIT
CU�4 6804 W 1/5 6048 VA 16.8 A 208 V 3 A 20,22,24 3#8,1#10G,3/4"C 60/3/3R W/UNIT
CU�5A 4536 W 1/8 3946 VA 11.0 A 208 V 3 A 19,21,23 3#12,1#12G,3/4"C 30/3/3R W/UNIT
CU�5B 4536 W 1/8 3946 VA 11.0 A 208 V 3 A 25,27,29 3#12,1#12G,3/4"C 30/3/3R W/UNIT
CU�6 5832 W 1/5 5328 VA 14.8 A 208 V 3 A 26,28,30 3#10,1#10G,3/4"C 30/3/3R W/UNIT
CU�7 5832 W 1/5 5364 VA 14.9 A 208 V 3 A 31,33,35 3#10,1#10G,3/4"C 30/3/3R W/UNIT
FCU�1 0 W 3/4 1548 VA 12.9 A 120 V 1 A 1 2#12,1#12G,3/4"C $M W/UNIT
FCU�2 0 W 3/4 1548 VA 12.9 A 120 V 1 A 3 2#12,1#12G,3/4"C $M W/UNIT
FCU�3 0 W 3/4 1548 VA 12.9 A 120 V 1 A 5 2#12,1#12G,3/4"C $M W/UNIT
FCU�4 0 W 3/4 1548 VA 12.9 A 120 V 1 A 7 2#10,1#10G,3/4"C $M W/UNIT
FCU�5A 0 W 3/4 1548 VA 12.9 A 120 V 1 A 9 2#12,1#12G,3/4"C $M W/UNIT
FCU�5B 0 W 3/4 1548 VA 12.9 A 120 V 1 A 11 2#10,1#10G,3/4"C $M W/UNIT
FCU�6 0 W 3/4 1548 VA 12.9 A 120 V 1 A 13 2#10,1#10G,3/4"C $M W/UNIT
FCU�7 0 W 3/4 1548 VA 12.9 A 120 V 1 A 15 2#10,1#10G,3/4"C $M W/UNIT
TEF�A 0 W 1/18 120 VA 1.0 A 120 V 1 B 47 2#12,1#12G,3/4"C $M W/UNIT CIRCUIT W/ LIGHTS REFER TOPLAN
TEF�B 0 W 1/10 120 VA 1.0 A 120 V 1 B 52 2#12,1#12G,3/4"C $M W/UNIT CIRCUIT W/ LIGHTS REFER TOPLAN
ELECTRICAL SPECIFICATION
GENERAL
1.01 GENERAL REQUIREMENTS:
A. Work shall be in accordance with the latest editions of the National Electrical Code, State,
and local authorities having jurisdiction.
B. Material shall be new and have the Underwriters Laboratories (UL) label, or be listed by UL
for the intended use.
C. Pay for all required permits and inspection fees.
D. Submit shop drawings and samples where specifically requested, as4built drawings and
Operation and Maintenance Manual.
1.02 SCOPE:
A. Interior Work
1. Provide complete electrical systems for the following:
a. Lighting and power distribution.
b. Lighting Fixtures and control.
c. Convenience and special receptacles.
d. Empty raceway systems for Telephone and Data.
e. Wiring to Plumbing, Heating, Ventilating and Air Conditioning equipment.
C. Submittals
1. Include complete materials list of all items proposed to be furnished and installed.
2. Manufacturer's equipment specifications and other data required to demonstrate
compliance with the specified requirements.
1.03 PRODUCTS:
A. Conduit:
1. Provide new conduit and deliver to the site in standard lengths.
2. Galvanized Rigid Steel Conduit and Couplings: Hot4dipped galvanized or sherardized
inside and out, with galvanized threads. Provide insulated throat metallic bushings.
3. Electric Metallic Steel Tubing: Hot4dipped galvanized or sherardized on exterior
surface. Provide wrench compression type couplings and insulated throat
compression connectors.
4. Flexible Conduit: Manufactured from single strip steel, hot4dipped galvanized. Provide
insulated die4cast connectors with ridges that thread into the inside of the conduit to
ensure a force fit, as manufactured by D&H Electric Company or equal. Binding4screw
type connectors are not acceptable.
5. Liquidtight Flexible Conduit: Identical to flexible steel conduit but with overall polyvinyl
chloride plastic jacket. Provide insulating connectors, Appleton STN Series, or equal.
All liquidtight flexible conduit shall include in its construction a bonding conductor,
sized to NEC requirements, per its sized load.
6. Polyvinyl Chloride plastic conduit: PVC Schedule 40, with slip fittings and connectors.
7. Underground 4 PVC.
8. Underground elbows 4 GRS
9. Above ground 4 EMT.
B. Wire and Cable:
1. All wire and cable for lighting and power systems shall be soft4drawn annealed copper
with 98 percent conductivity, 6004volt insulation, unless otherwise noted. Aluminum
wire and cable will not be permitted unless approved by engineer in advance.
2. All wire and cable shall be new and manufactured not more than 12 months prior to
installation. Each coil or reel shall bear the UL label and shall be marked with AWG or
circular wire size, voltage rating, insulation type, type of stranding, (and shielding,
where applicable), manufacturer's name, trade name, month and year when
manufactured. Wire shall be marked continuously with insulation type, wire size and
voltage rating.
3. Minimum wire size used shall be #12 AWG, except control circuits may be #14 AWG.
4. Conductors for all auxiliary and communication systems shall be as indicated or as
recommended by the system equipment manufacturer.
5. Conductors No. 10 AWG and smaller shall be solid; No. 8 and larger shall be stranded.
6. Insulation shall be type THHN/THWN or XHHW, to suit installed condition per National
Electrical Code. Use type XHHW for service conductors, use type THHN/THWN for
other conductors.
7. Conductors installed in areas subjected to temperatures exceeding 60°C (140°F);
terminating in incandescent lighting fixtures and installed through or into housing
containing ballasts shall be type AVA.
8. For all sizes, conductors with mineral filled cross4linked thermosetting polyethylene
insulation, UL4type XHHW rated 75°C (167°F) in wet or dry locations may be used.
C. Outlet Boxes:
1. Provide all boxes necessary for proper installation of electrical work in compliance with
codes and regulations. Each box shall have the volume required by the National
Electrical Code for the number of conductors enclosed in the box.
2. Provide 14piece galvanized pressed steel knockout type boxes, minimum sized 4"
square by 141/2" deep, in all wall and ceiling
locations unless otherwise indicated or required.
3. Cast ferrous or aluminum boxes and fittings shall be of the threaded hub type with
integral end4stop when located in exterior or normally wet locations.
D. Pull Boxes:
1. Where pull boxes are indicated or required on walls, in ceilings and in dry locations,
provide boxes constructed of code4gage sheet steel finished with one coat of metal
primer and one coat of primer sealer.
2. Ceiling pull boxes shall be recessed or concealed unless otherwise noted. In finished
areas, paint exposed surfaces to match ceiling or wall decor.
E. Wiring Devices:
1. General: Wiring devices shall be of the molded composition type, specification grade,
rated at 125 volts, unless otherwise noted or specified. All devices shall be flush
mounted unless otherwise noted and with finish matching device plates. Local
switches shall have alternating current ratings equal to full nominal capacity whenever
handling tungsten filament or inductive loads. Switches for 120 volt circuits shall be
rated 20 amperes and of the quiet action type. All key type switches shall be keyed
identically. Receptacles shall be of the NEMA Standard configuration for each
application, using a horseshoe shaped grounding pole. Color of devices and plates
shall be as selected by Architect.
2. Receptacles: Provide types in accordance with NEMA Standard configuration as
shown and hereinafter specified.
a. Duplex receptacles for 1204volt, single4phase service shall be specification grade,
rated 20 amperes, 125 volt, back or side wired, urea4molded. Receptacles shall
be Hubbell No. BR20.
b. Double duplex (quadruplex) receptacles for 1204volt, single phase service to be
same as duplex receptacles with two duplex receptacles installed in one 4" x 4"
outlet box with one 24gang faceplate.
c. Single receptacles for 1204volt, 204ampere, 34wire service shall be similar to
duplex receptacles, Hubbell No. 1877.
d. Receptacles identified as "GFI" or “GF” shall be ground fault interrupter type, 20
amperes, 120 volt, Hubbell No. GF20.
3. Toggle Switches: Single pole, 34way and 44way.
a. 120 or 277 volt lighting switches shall be rated 20 amperes, 120/277 volts, A.C.,
Hubbell No. CSB120.
F. Device Plates:
1. Provide plates for all outlet boxes and fittings of all systems except at outlets where
fixture canopies are used.
3. Provide plates of noncombustible, mar4resistant thermosetting plastic, 0.1" thick and of
plain style unless otherwise indicated.
4. Provide galvanized steel plates with stainless steel screws in all electrical and
mechanical equipment rooms, utility rooms, unfinished areas, and on all indoor surface
mounted boxes, and exposed extension rings. Plates shall be square or rectangular,
and hot4dipped galvanized or sherardized.
5. In wet areas, weatherproof exposed locations, and areas subject to hosing down, use
individually gasketed stainless steel cover plates.
G. Terminal Cabinets:
1. Provide surface or recess mounted types of sizes as indicated, constructed of
code4gauge sheet steel with hinged, lockable doors.
H. Nameplates:
1. Provide a nameplate for each panelboard, terminal cabinet, backboard, individually
mounted circuit breaker or motor control, disconnect switch, pull box, control panel,
push4button station, contactor, relay, all spare conduit stub4ups, and for all other
control devices or major items of electrical equipment.
2. Provide laminated plastic nameplates engraved in minimum 1/4" (6.4 mm) high black
letters on white background to correspond with the designations on the Drawings.
3. Attach nameplates to equipment with rivets, nuts and bolts, or self tapping sheet metal
screws.
I.
Safety Switches:
1. Unless indicated otherwise, use only unfused type and use only for motor equipment
disconnects. Provide switches with the number of poles and the voltage, current, and
horsepower ratings as required. Provide externally operable, quick4make, quick4break
type with cover interlock and lockable in either the open or closed position. Unless
indicated otherwise, provide switches indoors in NEMA Type 1 enclosures; outdoors or
where indicated to be weatherproof provide NEMA Type 3R raintight enclosures.
Switches shall be heavy4duty type horsepower rated meeting NEMA Specifications.
J.
Molded Case Circuit Breakers:
1. Provide molded4case circuit breakers of frame sizes, trip ratings and RMS symmetrical
interrupting ratings indicated.
2. Circuit breakers shall have permanent thermal and instantaneous magnetic trip.
Operating handle shall be a trip4free, toggle4type operating mechanism with
quick4make, quick4break action and positive handle trip indication.
K.
Fuses:
1. Below 200 amperes: Class K1, 200,000 amperes interrupting capacity Bussman
"Limitron", Chase4Shawmut "Amp4Trap Form 600", or Economy "Econolim".
2. 200 & 400 amperes fuse: Class RK1 Dual4Element Time4Delay fuse.
L.
Panelboards:
1. Provide circuit breaker type, dead4front safety style panelboards, with protective
devices in quantities, ratings, types, as required. Include anti4turn solderless pressure
type main lug connectors approved for use with copper conductors. Panels shall be
suitable for connecting feeders at top or bottom of panel. Equip with copper bus bars
with not less than 984percent conductivity, and full
sized neutral bus, unless otherwise indicated. Provide suitable lugs on neutral bus for
outgoing feeders requiring neutral connections. Provide molded case main and branch
circuit breakers, with toggle handles that indicate when tripped.
2. Enclosures for all panelboards shall be fabricated by one manufacturer.
3. Provide feed4thru lugs and additional feed4thru gutter space as required.
4. Provide barriered space for mounting contactors and control devices with a hinged
door and lock, where shown or required.
5. Breakers serving loads comprised of large wattage incandescent lamps shall be
equipped with desensitized magnetic trip mechanisms which prevent tripping by
in4rush currents.
6. Provide approved handle ties for individual circuit breakers protecting each
ungrounded branch circuit conductor of multi4wire branch circuits.
7. Provide neatly typed circuit index cards, clearly and correctly identifying all circuits,
mounted in card holders, behind glass or heavy plastic on the inside of the panelboard
doors. Indexes shall accurately record all room numbers.
8. Electrical Code Compliance: Comply with applicable local code requirements of the
authority having jurisdiction and NEC Article 384 as applicable to installation, and
construction of electrical panelboards and enclosures.
9. UL Compliance: Comply with applicable requirements of UL 67 "Electric Panelboards"
and UL's 50, 869, 486A, 486B, and 1053 pertaining to panelboards, accessories and
enclosures. Provide panelboard units which are UL4listed and labeled.
10. NEMA Compliance: Comply with NEMA Standards Publication No. 250 "Enclosures
for Electrical Equipment (1000 Volts Maximum)", Publication No. PB 1 "Panelboards",
and Publication No. PB 1.1 "General Instructions for Proper Installation, Operation and
Maintenance of Panelboards Rated 600 Volts or Less".
11. Panelboards for supplying Tenant Units circuiting for equipment rated at 120 volts shall
be 120/208 volts, 3 phase, 4 wire.
M. Lighting Fixtures:
1. General: Provide recessed, surface and pendant4mounted lighting fixtures, complete
with lamps and ballasts.
2. Exterior Light Fixtures: Provide recessed or surface mounted fixtures on building as
indicated.
3. Fluorescent Lighting Fixtures:
a. In office spaces and finished areas, fixtures shall be low brightness recessed
type, 2'x2' or 2'x4', with either 2 or 3 lamps. Fixtures shall have parabolic4shaped
reflector cells of semi4specular anodized aluminum, formed from one piece
brushed finished material. Parabolic blades shall be rigid, completely closed at
the top by integral flanges designed for maximum reflectance.
b. In areas not requiring low brightness louvers, such as restrooms, fixtures shall be
similar to above except with acrylic lens. Provide lens constructed of 100 percent
virgin acrylic, 0.125" thick, with female conical prisms having 3/16" square base.
Minimum depth of prisms shall be 0.08". Cones shall run 45 degrees to the
parallel and perpendicular axis of the lens panel. Lenses shall be destaticized,
and of the one4piece type. Provide lenses as made by KSH Incorporated or equal.
4. Ballasts:
a. Fluorescent Ballasts: Provide electronic type with characteristics to suit the
lamps, with voltage rating as required by the circuit in which fixture is connected.
Provide ballasts with the following features:
(1) Type "P" 4 integral thermal protection.
(2) CBM certified by ETL.
(3) Power factor not less than 90 percent.
(4) Quietest sound rating commercially available for each type.
(5) Third harmonic content: Maximum 15%.
(6) Total harmonic content: Maximum 10%.
(7) Maximum crest factor: 1.7.
b. Manufacturers: Advance, Dual4Lite, Jefferson or Universal.
5. Lamps: Provide lamps for all fixtures as indicated on the drawings and as follows:
a. Fluorescent:
(1) In general, fluorescent lamps shall be energy saving type, rapid start, T48, or
compact type PL, to suit fixture type.
b. All lamps to meet the requirements of the 1992 Federal Energy Policy Act.
c. Manufacturer: General Electric, Phillips or Osram/Sylvania.
6. Lighting fixtures shall be as described by the lighting fixture schedule.
1.04 INSTALLATION:
All material and equipment shall be installed in accordance with approved
recommendations of the manufacturer and conforming to the Contract Documents. The
installation shall conform to the applicable codes, rules and regulations. The Drawings
indicate the extent and the general location and arrangement of equipment, conduit and
wiring.
A. Conduit and Raceway:
1. Run concealed wherever possible.
2. Route conduit to avoid drains, other gravity lines and all obstructions.
3. Keep conduit at least 12" from the coverings on hot water and steam pipes, at least
18" from the covering on flues and breechings, and at least 24" from radiant heaters.
4. Run conduit exposed to view parallel with or at right angles to structural members,
walls or surfaces of the building. Route exposed conduit to preserve headroom,
access space and work space.
5. Changes in direction of runs shall be made with symmetrical bends or cast metal
fitting. Field4made bends and offsets shall be made with an approved hickey or
conduit4bending machine. Bend radius shall be not less than allowed in the NEC.
Crushed or deformed raceways shall not be installed.
6. Raceways shall be securely supported and fastened in place with pipe straps, wall
brackets, hangers, threaded C4clamps/beam clamps with retainers and locknut, or
ceiling trapeze at intervals not exceeding 10 feet. Fastenings shall be by expansion
bolt on concrete or brick; by machine screws, welded threaded studs. Nail4type nylon
anchors or threaded studs driven in by a powder charge and provided with lock washer
and nuts may be used in lieu of expansion bolts or machine screws.
7. Above suspended ceiling, support conduit on or from the structure by using galvanized
clips or galvanized brackets designed for the purpose. Hanging of equipment from
channel will not be permitted.
8. In steel stud construction: Rigidly support conduit at maximum 4' intervals with
galvanized clips or galvanized brackets designed for that purpose. Use galvanized
steel hangers of the types made specifically for the purpose where required.
9. Provide seismic bracing for conduits 241/2" diameter and larger.
10. Minimum conduit size shall be 3/4".
11. All conduit containing wiring operating at 120 volts or higher shall contain a code sized
equipment ground conductor.
12. Conduit for underground services shall be PVC encased in concrete.
C. Conductors:
1. Make joints, splices, taps and connections for 6004volt conductors with solderless
connectors. Use only plated copper alloy connectors or lugs; aluminum connectors or
lugs are not acceptable.
a. For #10 AWG and smaller: use #M "Scotchlok" or Ideal "Super Nut".
b. For #8 AWG and larger: Use T&B "Lock4Tie" connectors, Burndy Versitaps and
heavy4duty connectors, or O.Z. solderless connectors.
2. Retighten all bolt type connectors 24 to 48 hours after initial installation and before
taping.
3. Tape all connections made with non4insulated type connectors with rubber4type, 141/2
times the thickness of the conductor insulation, then cover with Scotch No. 23 tape.
D. Lighting Fixtures:
1. Verify the ceiling condition for each fixture and provide fixture complete with proper
mounting accessories required for the ceiling condition in which the fixture is mounted.
2. Where fixtures are for lay4in mounting in an exposed runner type of ceiling, the
additional ceiling cross runners required for the fixtures will be provided as part of the
ceiling work. In such ceilings or similar, provide each fixture with clips (4 required) or
equivalent means to prevent the accidental disengagement of the fixtures from the
ceiling. Where fixtures in such ceilings are square or rectangular in shape, provide
each fixture with two (2) #12 AWG galvanized steel wires, at diagonally opposite
corners, and secure to the building structure.
E. Grounding:
1. All metallic enclosures and raceways shall be electrically grounded per NEC Article
250.
F. Tests:
1. General: In addition to tests required by other sections, perform or cause to be
performed, provide all tests specified for electrical work.
2. Operating Test: After the installation is completed, conduct an operating test.
Equipment shall be demonstrated to operate in accordance with the requirements
herein, and to the satisfaction of the Owner's representative. All tests shall be
performed in the presence of the Architect or his representative. The Contractor shall
furnish instruments and personnel required for the test.
G. Protection:
1. Protect materials before, during and after installation and protect installed work and
materials of all other trades.
H. Replacements:
1. In the event of damage, immediately make all repairs and replacements necessary for
the approval of the Architect and at no additional cost to the Owner.
I. Delivery and Storage:
1. Deliver all materials to the job site in their original unopened containers, where
applicable, with all labels intact and legible at time of use. Store in strict accordance
with the manufacturer's recommendations as approved by the Architect.
2. Provide safety sliding cover plate for electrical outlets less than or equal to 36" A.F.F. in classrooms,
corridors, and adult restrooms.
214029
P E
R M
I T
S
E T
. N
O T
R
E L
E A
S E
D F
O R
C
O N
S T
R U
C T
I O
N .
JOB NUMBER: 20144008
CHECKED BY: RKC
DATE: 07/16/2014
REVISIONS
DATE: DESCRIPTION:
PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO
PROJECT LOCATION:
40444
3449
531
| 6
83 D
AY
LIL
Y C
T. | A
CW
OR
TH
, G
A 3
0102
INF
O@
CA
LB
ER
TD
ES
IGN
.CO
M
ALBERTDESIGNGROUP,LLC
Pri
mro
se S
choo
lsR
R
The
Lea
der
in E
duca
tional
Child C
are
3660 C
edar
cres
t R
oad
, Acw
ort
h, G
A 3
0101
770 5
29 4
100
Copyri
ght
© 2
012. T
hes
e dra
win
gs
and t
he
des
ign r
epre
sente
d h
ereb
y a
re t
he
excl
usi
ve
pro
per
ty o
f P
rim
rose
Sch
ool
Fra
nch
isin
g C
o. R
epro
duct
ion o
r an
y u
se o
f th
ese
dra
win
gs
oth
er t
han
for
the
pro
ject
inte
nded
wit
hout
the
expre
ss w
ritt
enco
nse
nt
of
Pri
mro
se S
chool
Fra
nch
isin
g C
o. is
pro
hib
ited
. A
ny u
nau
thori
zed u
se w
ill
be
subje
ct t
o l
egal
act
ion.
E46
SPECIFICATIONS