J 2 OC 3 4 P K M J J C DESCRIPTION SYMBOL ELECTRICAL SYMBOL LEGEND MTG. HT. SINGLE POLE SINGLE THROW TOGGLE SWITCH TWO SINGLE POLE SINGLE THROW TOGGLE SWITCHES AND BALLAST COMBINATION TO CONTROL OUTER LAMPS ON ONE SWITCH AND INNER LAMP(S) ON THE OTHER SWITCH DOUBLE POLE SINGLE THROW TOGGLE SWITCH THREEWAY TOGGLE SWITCH FOURWAY TOGGLE SWITCH SINGLE POLE SINGLE THROW TOGGLE SWITCH WITH PILOT LAMP SINGLE POLE SINGLE THROW KEYED TOGGLE SWITCH SINGLE POLE SINGLE THROW PRESSURE TYPE TOGGLE SWITCH MANUAL MOTOR RATED SWITCH WITH OVERLOAD PROTECTION DIMMER SWITCH THREEWAY DIMMER SWITCH INFRARED OCCUPANCY SENSOR WITH MANUAL ON/OFF SWITCH ULTRASONIC OCCUPANCY SENSOR, WALL / CEILING MOUNTED INFRARED OCCUPANCY SENSOR, WALL / CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR, WALL / CEILING MOUNTED OCCUPANCY SENSOR POWER PACK ELECTRICAL ABBREVIATIONS ALTERNATING CURRENT AC ABOVE FINISHED FLOOR AFF ABOVE FINISHED GRADE AFG ALUMINUM AL AUTOMATIC TRANSFER SWITCH ATS AMERICAN WIRE GAUGE AWG BELOW CEILING BC BREAKER BKR COMMUNITY ACCESS TELEVISION CATV CIRCUIT BREAKER CB CLOSED CIRCUIT TELEVISION CCTV CIRCUIT CKT CEILING CLG CONDUIT ONLY CO CONTROL CNTL CENTRAL PROCESSING UNIT CPU COPPER CU CURRENT TRANSFORMER CT DIRECT CURRENT DC DELTA DIMMER DIM DISCONNECT SWITCH DISC DOWN DN EMERGENCY E EMPTY CONDUIT EC EXISTING EX FIRE ALARM FA FIRE ALARM CONTROL PANEL FACP FEEDER FDR FLOOR FL FUSE OR FUSED F FULL VOLTAGE NONREVERSING FVNR GENERATOR GEN GROUND FAULT CIRCUIT INTERRUPTER GFCI GROUND FAULT PROTECTION GF GALVANIZED RIGID STEEL CONDUIT GRC OR GRS GROUND G OR GND HEIGHT H OR HT HIGH INTENSITY DISCHARGE HID HORSEPOWER HP HANDOFFAUTOMATIC HOA HERTZ HZ ISOLATED GROUND IG ISOLATED ISO JUNCTION BOX J OR JB KILO, THOUSAND K THOUSAND CIRCULAR MILLS KCMIL LIGHT EMITTING DIODE LED MOTOR M MASTER ANTENNA TELEVISION MATV MAIN CIRCUIT BREAKER MCB MOTOR CONTROL CENTER MCC MAN HOLE MH MAIN LUGS ONLY MLO MOUNT MT MOUNTING MTG NORMALLY CLOSED NC NATIONAL ELECTRICAL CODE NEC NON FUSED NF NATIONAL FIRE PROTECTION ASSOCIATION NFPA NOT IN CONTRACT NIC NIGHT LIGHT NL NORMALLY OPEN NO NOT TO SCALE NTS ON CENTER OC OVERLOAD OL POLE P PHOTOELECTRIC CONTROL PC PANELBOARD PNL POTENTIAL TRANSFORMER PT POLYVINYL CHLORIDE PVC RELAY R REMOTE CONTROL RC RECEPTACLE RECPT REFERENCE REF ROOT MEAN SQUARE RMS SUB FED LUGS SFL SYMMETRICAL SYM SWITCH SW SWITCHBOARD SWBD TELEPHONE BACKBOARD TBB TELEPHONE TEL TELEVISION TV TRANSIENT VOLTAGE SURGE SUPRESSOR TVSS TYPICAL TYP UNDERGROUND UG UNDERWRITER'S LABORATORY UL UNINTERRUPTED POWER SUPPLY UPS VOLTS V VOLTAMPERE VA WATTS W WEATHERPROOF WHILE IN USE WP TRANSFORMER XFMR EXPLOSION PROOF XP WYE Y IMPEDANCE Z WHERE ABBREVIATIONS ARE USED IN THE DOCUMENTS AND NOT LISTED IN THE FOLLOWING, REFER TO ANSI/IEEE STANDARD 100 AND FOR MECHANICAL EQUIPMENT REFER TO THE MECHANICAL SYSTEMS ABBREVIATIONS SCHEDULE. SINGLE RECEPTACLE WALL / FLOOR / CEILING MOUNTED DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED ABOVE COUNTER RECEPTACLE SINGLE / DUPLEX / DOUBLE DUPLEX. SPLIT WIRE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED SWITCH CONTROLLED DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED SPECIAL PURPOSE RECEPTACLE WALL / FLOOR / CEILING MOUNTED CLOCK RECEPTACLE WALL MOUNTED JUNCTION BOX WALL / FLOOR / CEILING OR EQUIPMENT MOUNTED POKETHRU JUNCTION BOX POWER POLE DEDICATED CIRCUIT ARROWHEAD INDICATES HOMERUN. X1,3,5 ADJACENT TO HOMERUN ARROWHEADS INDICATES HOMERUN TO PANEL X, CIRCUIT NUMBERS 1,3, AND 5. INDICATES CIRCUIT CONTINUATION OF PANEL X CIRCUITS 3 AND 5 RACEWAY INSTALLED CONCEALED IN WALL AND/OR ABOVE CEILING RACEWAY INSTALLED CONCEALED IN SLAB OR BELOW GRADE RACEWAY INSTALLED EXPOSED GROUND FLEXIBLE RACEWAY (6'0" MAX LENGTH) CONDUIT UP / CONDUIT DOWN CONDUIT TERMINATION (STUBOUT) CONDUIT CONTINUATION BUS DUCT (SIZE/RATING AS NOTED) MULTIPLE RACEWAY CABLE TRAY CABLE TRAY ELBOW AND 'T' CONNECTORS HANDHOLE MANHOLE FLUORESCENT LIGHT FIXTURE. OVERHEAD / WALL MOUNTED FLUORESCENT STRIP OR INDUSTRIAL LIGHT FIXTURE LIGHT FIXTURE CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED DIRECTIONAL OR WALL WASH LIGHT FIXTURE EXIT SIGN INTERNALLY ILLUMINATED CEILING / WALL MOUNTED. PROVIDE ARROWS AS INDICATED. EGRESS AND/OR EMERGENCY LIGHT FIXTURE EGRESS AND/OF EMERGENCY LIGHT FIXTURE, HALF OF LAMPS OR CENTER LAMP ON EMERGENCY CIRCUIT. TRACK LIGHT HEADS AND TRACK STEP LIGHT LANDSCAPE UPLIGHT FIXTURE BOLLARD FIXTURE AND BASE SINGLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE DOUBLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE QUADRUPLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE LIGHT FIXTURE WITH BATTERY BACKUP GRID, RECESSED, OR SURFACE MOUNT FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM MANUAL INITIATING STATION FIRE ALARM AUDIO NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED FIRE ALARM AUDIO AND VISUAL NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED FIRE ALARM VISUAL NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED FIRE ALARM MINI HORN, WALL / CEILING MOUNTED. FIRE ALARM BELL, WALL MOUNTED INDICATES CANDELA INTENSITY, DECIBEL RATING AND ZONE OF FIRE ALARM ANNUCIATION DEVICES. SMOKE DETECTOR, WALL / CEILING MOUNTED HEAT DETECTOR, WALL / CEILING MOUNTED CARBON MONOXIDE DETECTOR, WALL / CEILING MOUNTED DUCT DETECTOR MAGNETIC DOOR HOLDER AND RELEASE, WALL / HARDWARE MOUNTED COMBINATION SMOKE DETECTOR AND MAGNETIC DOOR HOLDER AND RELEASE FIRE COMMUNICATIONS TELEPHONE JACK FLUSH MOUNTED PANELBOARD SURFACE MOUNTED PANELBOARD 48" 48" 48" 48" 48" 48" 48" 48" 48" 48" 80" / 80" / 80" / 18" / / 18" / / 18" / / ARCHITECT 18" / / 18" / / 18" / / 48" 80" / 80" / 80" / 80" / 48" ALTERNATING CURRENT AC NOTES L9 L10,11 L10,11 L9 L1,7,8 L1,7,8 L7 L5 SYMBOL LEGEND NOTES GENERAL NOTES NONFUSIBLE DISCONNECT SWITCH. RATING / POLES / NEMA ENCLOSURE FUSIBLE DISCONNECT SWITCH. RATING / POLES / NEMA ENCLOSURE / FUSE RATING MAGNETIC MOTOR STARTER. NEMA SIZE RATING / NEMA ENCLOSURE COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECTING MEANS. NEMA SIZE RATING / NEMA ENCLOSURE / FUSE RATING (WHERE REQUIRED) VARIABLE SPEED SOLID STATE STARTER AND DISCONNECTING MEANS. NEMA SIZE RATING / NEMA ENCLOSURE EQUIPMENT AS INDICATED TIME CLOCK CONTACTOR VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER TELEVISION OUTLET, WALL / FLOOR / CEILING MOUNTED TELECOMMUNICATIONS BACKBOARD. LOW VOLTAGE PUSH BUTTON AMMETER VOLTMETER DOOR CHIME 18" / / 18" / / 18" 48" L6 L4 L1 EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL BRANCH CIRCUIT RACEWAYS. L2 UNLESS NOTED, MOUNTING HEIGHT DIMENSIONS ARE TO THE CENTER OF THE DEVICE OR OUTLET ABOVE FINISHED GRADE OR FINISHED FLOOR. L3 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST TELEPHONE BACKBOARD, UNLESS OTHERWISE INDICATED OR SPECIFIED. L4 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST DATA SYSTEM BACKBOARD L5 SPECIAL PURPOSE RECEPTACLE OUTLET, REFER TO KEYNOTES ON RESPECTIVE DRAWING FOR DESCRIPTION. L6 TELEPHONE BACKBOARD TO BE PLYWOOD PAINTED WITH LOW SMOKE RELEASE PAINT. PROVIDE GROUND CONDUCTOR AND DOUBLE DUPLEX RECEPTACLE. REFER TO SPECIFICATIONS. L7 DEDICATED CIRCUITS SHALL NOT SHARE A COMMON GROUND OR NEUTRAL CONDUCTOR WITH NON DEDICATED CIRCUITS. DEDICATED CIRCUITS SHALL BE INSTALLED IN INDIVIDUAL RACEWAY SYSTEMS. DEDICATED CIRCUIT HOMERUNS SHALL NOT BE COMBINED TO SHARE NEUTRAL OR GROUND CONDUCTORS. L8 NONDEDICATED BRANCH CIRCUITS SHALL CONSIST OF ONE PHASE CONDUCTOR, ONE NEUTRAL CONDUCTOR AND ONE GROUND CONDUCTOR. SINGLE PHASE HOMERUNS MAY BE COMBINED INTO THREE PHASE (a,b,c) 5wIRE HOMERUNS AT THE DISCRETION OF THE CONTRACTOR. L9 MOUNTING HEIGHT DIMENSIONS ARE TO THE BOTTOM OF THE DEVICE ABOVE FINISHED GRADE OR FINISHED FLOOR. L10 MOUNTING HEIGHT FOR THE BOTTOM OF THE AUDIBLE/VISUAL AND VISUAL DEVICE LENS SHALL BE 80" ABOVE FINISHED GRADE OR FINISHED FLOOR. L11 VISUAL DEVICES LOCATED IN SLEEPING AREAS AND MOUNTED WITHIN 24" OF THE CEILING SHALL BE 177CD. MTG. HT. NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. COORDINATION NOTES REVIEW ALL SPECIFICATIONS AND DOCUMENTS FOR ELECTRICAL REQUIREMENTS AND LOCATION OF EQUIPMENT REQUIRING ELECTRICAL SERVICE. PROVIDE SERVICE TO AND MAKE CONNECTIONS TO ALL SUCH EQUIPMENT. REFER TO MECHANICAL AND PLUMBING DOCUMENTS FOR ALL MECHANICAL AND PLUMBING EQUIPMENT POWER REQUIREMENTS. PROVIDE QUANTITY OF BRANCH CIRCUITS, SWITCHES, DISCONNECTS, STARTERS, ETC., FOR EQUIPMENT AS REQUIRED. REFER TO FIRE PROTECTION DRAWINGS FOR ALL DEVICE REQUIRING ELECTRIC SERVICE AND/OR FIRE ALARM INTERFACE. PROVIDE CONNECTIONS AS REQUIRED. 1. 2. 3. * / / / / / / / / / / / / / / / / / / / (DED) PP ZONE 60A/3/3R/40A SIZE 2/3R SIZE 2/3R/40A 60A/3/3R A V SIZE 2/1 H 11 H H 90 90 F M DB CD M F FACP F HH MH X1,3,5 3,5 TV TV F C TC CO CO OU OI OD OU OI OD FAAP TV MOTOR 3 PP S S THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT. REVIEW ARCHITECTURAL DRAWINGS FOR DOOR SWINGS, CABINETS, COUNTERS, AND BUILTIN EQUIPMENT; CONDITIONS INDICATED ON ARCHITECTURAL PLANS SHALL GOVERN. COORDINATE INSTALLATION OF ELECTRICAL EQUIPMENT WITH STRUCTURAL SYSTEM AND MECHANICAL EQUIPMENT AND ACCESS THERETO. COORDINATE INSTALLATION OF RECESS ELECTRICAL EQUIPMENT WITH CONCEALED DUCTWORK AND PIPING. REFER TO ARCHITECTURAL DRAWINGS AND/OR INTERIOR DESIGN DRAWINGS FOR ALL DIMENSIONS AND STANDARD DETAILS. DO NOT SCALE. CAPITAL LETTERS BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. WHERE INDICATED ON DRAWINGS LOWER CASE LETTER INDICATES SWITCH LEG, DIMMER OR CONTROL DESIGNATION. NUMERAL BESIDE EQUIPMENT, DEVICE, OR OUTLETS INDICATES CIRCUIT CONNECTION. WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT UNLESS OTHERWISE INDICATED. EXTEND THREE (3) EMPTY 1" CONDUITS FROM EACH FLUSH MOUNTED PANEL TO POSITION ABOVE ACCESSIBLE CEILING, IF APPLICABLE. PROVIDE OUTLET BOX FITTING FOR EACH DEVICE, SIZE TO ACCOMMODATE DEVICE AND CONDUCTORS. WALL SWITCHES CONTROLLING 277 VAC CIRCUIT OF OPPOSITE PHASES (OR 120VAC) SHALL NOT BE INSTALLED IN A COMMON BOX UNLESS A PERMANENT BARRIER IS PROVIDED. ALL CONDUITS PENETRATING ROOF SHALL BE SEALED. SEE ARCHITECTURAL DOCUMENTS AND DETAILS. ALL RACEWAY AND EQUIPMENT SUPPORTS AND HANGERS SHALL BE ATTACHED TO STRUCTURAL MEMBERS. COORDINATE WITH STRUCTURAL DOCUMENTS. DISCONNECT SWITCHES, MOTOR STARTERS, AND OTHER ELECTRICAL EQUIPMENT INSTALLED ABOVE ACCESSIBLE CEILINGS AND REQUIRING ACCESS FOR MAINTENANCE, SHALL BE INSTALLED WITH BOTTOM OF DEVICE A MAXIMUM OF ONE (1) FOOT ABOVE CEILING TO PROVIDE READY ACCESSIBILITY. CODE AND MANUFACTURER REQUIRED CLEARANCES SHALL BE MAINTAINED. ACCESS PANELS SHALL BE CONSOLIDATED TO MINIMIZE THE QUANTITY REQUIRED. COORDINATE LOCATION WITH ARCHITECTURAL DOCUMENTS. THE PROPOSED LOCATION OF ACCESS PANELS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. ALL CIRCUIT SHALL BE 2#12,1#12G,3/4"C UNLESS NOTED OTHERWISE. PRIOR TO THE PANELBOARD ORDERING PROCESS, CONTRACTOR SHALL OBTAIN THE ACTUAL MAXIMUM AVAILABLE FAULT CURRENT DATA FROM THE UTILITY COMPANY AND PROVIDE FAULT CURRENT ANALYSIS FOR THE FACILITY ELECTRICAL SYSTEM. AIC RATING FOR SWITCHBOARD AND PANELBOARD SHALL BE REVISED TO BE ABLE TO SUSTAIN THE FAULT CURRENT FOUND BY THE FAULT CURRENT ANALYSIS. SERIES RATED PANELBOARDS AND BREAKERS ARE PROHIBITED. PROVIDE STARTERS AND DISCONNECTS FOR ALL MECHANICAL AND PLUMBING MOTORS AND EQUIPMENT WITH MOTORS, UNLESS STARTERS ARE PROVIDED BY MANUFACTURER OF EQUIPMENT. SIZE ALL STARTERS AND DISCONNECTS PER THE NATIONAL ELECTRICAL CODE. ALL SYMBOLS INDICATED IN LEGEND(S) MAY NOT NECESSARILY BE USED ON THIS PROJECT. WEATHER RESISTANT WR GRAPHICS LEGEND DESCRIPTION CUT LINE SHEET NUMBER SHEET NUMBER REVISION AREA REVISION DELTA DRAWING NUMBER DRAWING NUMBER COLUMN REFERENCE GRID SYMBOL E1.2 E1.2 1 1 DRAWING TITLE SCALE: # # AREA TO BE DETAILED KEYNOTE X 17. FIRE ALARM SYSTEM DRAWINGS AND SPECIFICATIONS SHOW THE MINIMUM REQUIREMENTS; ANY OTHER DEVICES REQUIRED MUST BE PART OF THE GENERAL CONTRACTOR'S BID NECESSARY TO BRING THE SYSTEM TO LOCAL CODE REQUIREMENTS. 18. CREATE AND SUBMIT FIRE ALARM SHOP DRAWINGS TO LOCAL AUTHORITY FOR APPROVAL. 19. ALL LOW VOLTAGE SYSTEMS TO BE BY OWNER'S VENDOR. CONDUIT AND BOXES BY CONTRACTOR. 18" / / L3 MULTI VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER 20. ALL 90 BATTERY BALLASTS USED FOR EMERGENCY/EGRESS LIGHTING SHALL PROVIDE A MINIMUM OF 700 LUMENS PER FIXTURE. 214029 P E R M I T S E T . N O T R E L E A S E D F O R C O N S T R U C T I O N . JOB NUMBER: 2014008 CHECKED BY: RKC DATE: 07/16/2014 REVISIONS DATE: DESCRIPTION: PRIMROSE SCHOOL at COLORADO STATION 4300 E. WARREN AVE. DENVER, CO PROJECT LOCATION: 4044349531 | 683 D AY L ILY C T. | ACWORTH, GA 30102 I NFO @C ALBERT D ESIGN.COM ALBERT D ESIGN G ROUP, LLC Primrose Schools R R The Leader in Educational Child Care 3660 Cedarcrest Road, Acworth, GA 30101 7705294100 Copyright © 2012. These drawings and the design represented hereby are the exclusive property of Primrose School Franchising Co. Reproduction or any use of these drawings other than for the project intended without the express written consent of Primrose School Franchising Co. is prohibited. Any unauthorized use will be subject to legal action. E0 LEGENDS, NOTES AND ABBREVIATIONS Electrical Sheet List Sheet Number Sheet Name E0 LEGENDS, NOTES AND ABBREVIATIONS E2 FLOOR PLAN LIGHTING E3 FLOOR PLAN POWER E4 RISER DIAGRAMS E5 SCHEDULES AND DETAILS E6 SPECIFICATIONS

Upload: dohuong

Post on 21-Mar-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

J

2

OC

3

4

P

K

M

JJ

C

DESCRIPTIONSYMBOL

ELECTRICAL SYMBOL LEGEND

MTG. HT.

SINGLE POLE SINGLE THROW TOGGLE SWITCH

TWO SINGLE POLE SINGLE THROW TOGGLE SWITCHES AND BALLASTCOMBINATION TO CONTROL OUTER LAMPS ON ONE SWITCH AND INNER LAMP(S)ON THE OTHER SWITCH

DOUBLE POLE SINGLE THROW TOGGLE SWITCH

THREE�WAY TOGGLE SWITCH

FOUR�WAY TOGGLE SWITCH

SINGLE POLE SINGLE THROW TOGGLE SWITCH WITH PILOT LAMP

SINGLE POLE SINGLE THROW KEYED TOGGLE SWITCH

SINGLE POLE SINGLE THROW PRESSURE TYPE TOGGLE SWITCH

MANUAL MOTOR RATED SWITCH WITH OVERLOAD PROTECTION

DIMMER SWITCH

THREE�WAY DIMMER SWITCH

INFRARED OCCUPANCY SENSOR WITH MANUAL ON/OFF SWITCH

ULTRASONIC OCCUPANCY SENSOR, WALL / CEILING MOUNTED

INFRARED OCCUPANCY SENSOR, WALL / CEILING MOUNTED

DUAL TECHNOLOGY OCCUPANCY SENSOR, WALL / CEILING MOUNTED

OCCUPANCY SENSOR POWER PACK

ELECTRICAL ABBREVIATIONS

ALTERNATING CURRENTAC

ABOVE FINISHED FLOORAFF

ABOVE FINISHED GRADEAFG

ALUMINUMAL

AUTOMATIC TRANSFER SWITCHATS

AMERICAN WIRE GAUGEAWG

BELOW CEILINGBC

BREAKERBKR

COMMUNITY ACCESS TELEVISIONCATV

CIRCUIT BREAKERCB

CLOSED CIRCUIT TELEVISIONCCTV

CIRCUITCKT

CEILINGCLG

CONDUIT ONLYCO

CONTROLCNTL

CENTRAL PROCESSING UNITCPU

COPPERCU

CURRENT TRANSFORMERCT

DIRECT CURRENTDC

DELTA

DIMMERDIM

DISCONNECT SWITCHDISC

DOWNDN

EMERGENCYE

EMPTY CONDUITEC

EXISTINGEX

FIRE ALARMFA

FIRE ALARM CONTROL PANELFACP

FEEDERFDR

FLOORFL

FUSE OR FUSEDF

FULL VOLTAGE NON�REVERSINGFVNR

GENERATORGEN

GROUND FAULT CIRCUIT INTERRUPTERGFCI

GROUND FAULT PROTECTIONGF

GALVANIZED RIGID STEEL CONDUITGRC OR GRS

GROUNDG OR GND

HEIGHTH OR HT

HIGH INTENSITY DISCHARGEHID

HORSEPOWERHP

HAND�OFF�AUTOMATICHOA

HERTZHZ

ISOLATED GROUNDIG

ISOLATEDISO

JUNCTION BOXJ OR JB

KILO, THOUSANDK

THOUSAND CIRCULAR MILLSKCMIL

LIGHT EMITTING DIODELED

MOTORM

MASTER ANTENNA TELEVISIONMATV

MAIN CIRCUIT BREAKERMCB

MOTOR CONTROL CENTERMCC

MAN HOLEMH

MAIN LUGS ONLYMLO

MOUNTMT

MOUNTINGMTG

NORMALLY CLOSEDNC

NATIONAL ELECTRICAL CODENEC

NON FUSEDNF

NATIONAL FIRE PROTECTION ASSOCIATIONNFPA

NOT IN CONTRACTNIC

NIGHT LIGHTNL

NORMALLY OPENNO

NOT TO SCALENTS

ON CENTEROC

OVERLOADOL

POLEP

PHOTOELECTRIC CONTROLPC

PANELBOARDPNL

POTENTIAL TRANSFORMERPT

POLY�VINYL CHLORIDEPVC

RELAYR

REMOTE CONTROLRC

RECEPTACLERECPT

REFERENCEREF

ROOT MEAN SQUARERMS

SUB FED LUGSSFL

SYMMETRICALSYM

SWITCHSW

SWITCHBOARDSWBD

TELEPHONE BACKBOARDTBB

TELEPHONETEL

TELEVISIONTV

TRANSIENT VOLTAGE SURGE SUPRESSORTVSS

TYPICALTYP

UNDERGROUNDUG

UNDERWRITER'S LABORATORYUL

UNINTERRUPTED POWER SUPPLYUPS

VOLTSV

VOLT�AMPEREVA

WATTSW

WEATHERPROOF WHILE IN USEWP

TRANSFORMERXFMR

EXPLOSION PROOFXP

WYEY

IMPEDANCEZ

WHERE ABBREVIATIONS ARE USED IN THE DOCUMENTS ANDNOT LISTED IN THE FOLLOWING, REFER TO ANSI/IEEE STANDARD100 AND FOR MECHANICAL EQUIPMENT REFER TO THEMECHANICAL SYSTEMS ABBREVIATIONS SCHEDULE.

SINGLE RECEPTACLE WALL / FLOOR / CEILING MOUNTED

DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED

DOUBLE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED

ABOVE COUNTER RECEPTACLE SINGLE / DUPLEX / DOUBLE DUPLEX.

SPLIT WIRE DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED

SWITCH CONTROLLED DUPLEX RECEPTACLE WALL / FLOOR / CEILING MOUNTED

SPECIAL PURPOSE RECEPTACLE WALL / FLOOR / CEILING MOUNTED

CLOCK RECEPTACLE WALL MOUNTED

JUNCTION BOX WALL / FLOOR / CEILING OR EQUIPMENT MOUNTED

POKE�THRU JUNCTION BOX

POWER POLE

DEDICATED CIRCUIT

ARROWHEAD INDICATES HOMERUN. X�1,3,5 ADJACENT TO HOMERUNARROWHEADS INDICATES HOMERUN TO PANEL X, CIRCUIT NUMBERS 1,3, AND 5.

INDICATES CIRCUIT CONTINUATION OF PANEL X CIRCUITS 3 AND 5

RACEWAY INSTALLED CONCEALED IN WALL AND/OR ABOVE CEILING

RACEWAY INSTALLED CONCEALED IN SLAB OR BELOW GRADE

RACEWAY INSTALLED EXPOSED

GROUND

FLEXIBLE RACEWAY (6'�0" MAX LENGTH)

CONDUIT UP / CONDUIT DOWN

CONDUIT TERMINATION (STUB�OUT)

CONDUIT CONTINUATION

BUS DUCT (SIZE/RATING AS NOTED)

MULTIPLE RACEWAY

CABLE TRAY

CABLE TRAY ELBOW AND 'T' CONNECTORS

HANDHOLE

MANHOLE

FLUORESCENT LIGHT FIXTURE. OVERHEAD / WALL MOUNTED

FLUORESCENT STRIP OR INDUSTRIAL LIGHT FIXTURE

LIGHT FIXTURE CEILING MOUNTED

LIGHT FIXTURE WALL MOUNTED

DIRECTIONAL OR WALL WASH LIGHT FIXTURE

EXIT SIGN INTERNALLY ILLUMINATED CEILING / WALL MOUNTED.PROVIDE ARROWS AS INDICATED.

EGRESS AND/OR EMERGENCY LIGHT FIXTURE

EGRESS AND/OF EMERGENCY LIGHT FIXTURE, HALF OF LAMPS OR CENTER LAMPON EMERGENCY CIRCUIT.

TRACK LIGHT HEADS AND TRACK

STEP LIGHT

LANDSCAPE UPLIGHT FIXTURE

BOLLARD FIXTURE AND BASE

SINGLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE

DOUBLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE

QUADRUPLE HEAD POLE MOUNTED EXTERIOR SITE LIGHTING FIXTURE

LIGHT FIXTURE WITH BATTERY BACKUP GRID, RECESSED, OR SURFACE MOUNT

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM MANUAL INITIATING STATION

FIRE ALARM AUDIO NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED

FIRE ALARM AUDIO AND VISUAL NOTIFICATION APPLIANCE, WALL / CEILINGMOUNTED

FIRE ALARM VISUAL NOTIFICATION APPLIANCE, WALL / CEILING MOUNTED

FIRE ALARM MINI HORN, WALL / CEILING MOUNTED.

FIRE ALARM BELL, WALL MOUNTED

INDICATES CANDELA INTENSITY, DECIBEL RATING AND ZONE OF FIRE ALARMANNUCIATION DEVICES.

SMOKE DETECTOR, WALL / CEILING MOUNTED

HEAT DETECTOR, WALL / CEILING MOUNTED

CARBON MONOXIDE DETECTOR, WALL / CEILING MOUNTED

DUCT DETECTOR

MAGNETIC DOOR HOLDER AND RELEASE, WALL / HARDWARE MOUNTED

COMBINATION SMOKE DETECTOR AND MAGNETIC DOOR HOLDER ANDRELEASE

FIRE COMMUNICATIONS TELEPHONE JACK

FLUSH MOUNTED PANELBOARD

SURFACE MOUNTED PANELBOARD

48"

48"

48"

48"

48"

48"

48"

48"

48"

48"

80" / �

80" / �

80" / �

18" / � / �

18" / � / �

18" / � / �

ARCHITECT

18" / � / �

18" / � / �

18" / � / �

48"

80" / �

80" / �

80" / �

80" / �

48"

ALTERNATING CURRENTAC

NOTES

L�9

L�10,11

L�10,11

L�9

L�1,7,8

L�1,7,8

L�7

L�5

SYMBOL LEGEND NOTES

GENERAL NOTES

NON�FUSIBLE DISCONNECT SWITCH.RATING / POLES / NEMA ENCLOSURE

FUSIBLE DISCONNECT SWITCH.RATING / POLES / NEMA ENCLOSURE / FUSE RATING

MAGNETIC MOTOR STARTER.NEMA SIZE RATING / NEMA ENCLOSURE

COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECTING MEANS.NEMA SIZE RATING / NEMA ENCLOSURE / FUSE RATING (WHERE REQUIRED)

VARIABLE SPEED SOLID STATE STARTER AND DISCONNECTING MEANS.NEMA SIZE RATING / NEMA ENCLOSURE

EQUIPMENT AS INDICATED

TIME CLOCK

CONTACTOR

VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER

TELEVISION OUTLET, WALL / FLOOR / CEILING MOUNTED

TELECOMMUNICATIONS BACKBOARD.

LOW VOLTAGE PUSH BUTTON

AMMETER

VOLTMETER

DOOR CHIME

18" / � / �

18" / � / �

18"

48"

L�6

L�4

L�1 EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL BRANCH CIRCUIT RACEWAYS.

L�2 UNLESS NOTED, MOUNTING HEIGHT DIMENSIONS ARE TO THE CENTER OF THE DEVICE OR OUTLETABOVE FINISHED GRADE OR FINISHED FLOOR.

L�3 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST TELEPHONE BACKBOARD, UNLESS OTHERWISEINDICATED OR SPECIFIED.

L�4 FURNISH AND INSTALL 3/4" CONDUIT HOMERUNS TO NEAREST DATA SYSTEM BACKBOARD

L�5 SPECIAL PURPOSE RECEPTACLE OUTLET, REFER TO KEYNOTES ON RESPECTIVE DRAWING FORDESCRIPTION.

L�6 TELEPHONE BACKBOARD TO BE PLYWOOD PAINTED WITH LOW SMOKE RELEASE PAINT. PROVIDE GROUNDCONDUCTOR AND DOUBLE DUPLEX RECEPTACLE. REFER TO SPECIFICATIONS.

L�7 DEDICATED CIRCUITS SHALL NOT SHARE A COMMON GROUND OR NEUTRAL CONDUCTOR WITH NON�DEDICATED CIRCUITS. DEDICATED CIRCUITS SHALL BE INSTALLED IN INDIVIDUAL RACEWAY SYSTEMS.DEDICATED CIRCUIT HOMERUNS SHALL NOT BE COMBINED TO SHARE NEUTRAL OR GROUND CONDUCTORS.

L�8 NON�DEDICATED BRANCH CIRCUITS SHALL CONSIST OF ONE PHASE CONDUCTOR, ONE NEUTRALCONDUCTOR AND ONE GROUND CONDUCTOR. SINGLE PHASE HOMERUNS MAY BE COMBINEDINTO THREE PHASE (a,b,c) 5�wIRE HOMERUNS AT THE DISCRETION OF THE CONTRACTOR.

L�9 MOUNTING HEIGHT DIMENSIONS ARE TO THE BOTTOM OF THE DEVICE ABOVE FINISHED GRADE OR FINISHEDFLOOR.

L�10 MOUNTING HEIGHT FOR THE BOTTOM OF THE AUDIBLE/VISUAL AND VISUAL DEVICE LENS SHALL BE80" ABOVE FINISHED GRADE OR FINISHED FLOOR.

L�11 VISUAL DEVICES LOCATED IN SLEEPING AREAS AND MOUNTED WITHIN 24" OF THE CEILING SHALL BE 177CD.

MTG. HT.NOTES 1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

COORDINATION NOTES

REVIEW ALL SPECIFICATIONS AND DOCUMENTS FOR ELECTRICAL REQUIREMENTS AND LOCATION OF EQUIPMENTREQUIRING ELECTRICAL SERVICE. PROVIDE SERVICE TO AND MAKE CONNECTIONS TO ALL SUCH EQUIPMENT.

REFER TO MECHANICAL AND PLUMBING DOCUMENTS FOR ALL MECHANICAL AND PLUMBING EQUIPMENT POWERREQUIREMENTS. PROVIDE QUANTITY OF BRANCH CIRCUITS, SWITCHES, DISCONNECTS, STARTERS, ETC., FOREQUIPMENT AS REQUIRED.

REFER TO FIRE PROTECTION DRAWINGS FOR ALL DEVICE REQUIRING ELECTRIC SERVICE AND/OR FIRE ALARMINTERFACE. PROVIDE CONNECTIONS AS REQUIRED.

1.

2.

3.

*

/

/

/

//

//

//

//

//

//

//

//

(DED)

PP

ZONE

60A/3/3R/40A

SIZE 2/3R

SIZE 2/3R/40A

60A/3/3R

A

V

SIZE 2/1

H

1�1

H H

9090

F

M

DBCD

M

F

FACP

F

HH

MH

X�1,3,5

3,5

TV TV

F

C

TC

CO CO

OU

OI

OD

OU

OI

OD

FAAP

TV

MOTOR

3

PP

S S

THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OFELECTRICAL EQUIPMENT. REVIEW ARCHITECTURAL DRAWINGS FOR DOOR SWINGS, CABINETS,COUNTERS, AND BUILT�IN EQUIPMENT; CONDITIONS INDICATED ON ARCHITECTURAL PLANS SHALLGOVERN. COORDINATE INSTALLATION OF ELECTRICAL EQUIPMENT WITH STRUCTURAL SYSTEM ANDMECHANICAL EQUIPMENT AND ACCESS THERETO. COORDINATE INSTALLATION OF RECESS ELECTRICALEQUIPMENT WITH CONCEALED DUCTWORK AND PIPING. REFER TO ARCHITECTURAL DRAWINGSAND/OR INTERIOR DESIGN DRAWINGS FOR ALL DIMENSIONS AND STANDARD DETAILS. DO NOT SCALE.

CAPITAL LETTERS BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. WHERE INDICATED ON DRAWINGSLOWER CASE LETTER INDICATES SWITCH LEG, DIMMER OR CONTROL DESIGNATION.

NUMERAL BESIDE EQUIPMENT, DEVICE, OR OUTLETS INDICATES CIRCUIT CONNECTION.

WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR ANDCONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT UNLESS OTHERWISE INDICATED.

EXTEND THREE (3) EMPTY 1" CONDUITS FROM EACH FLUSH MOUNTED PANEL TO POSITION ABOVEACCESSIBLE CEILING, IF APPLICABLE.

PROVIDE OUTLET BOX FITTING FOR EACH DEVICE, SIZE TO ACCOMMODATE DEVICE AND CONDUCTORS.

WALL SWITCHES CONTROLLING 277 VAC CIRCUIT OF OPPOSITE PHASES (OR 120VAC) SHALL NOT BE INSTALLEDIN A COMMON BOX UNLESS A PERMANENT BARRIER IS PROVIDED.

ALL CONDUITS PENETRATING ROOF SHALL BE SEALED. SEE ARCHITECTURAL DOCUMENTS AND DETAILS.

ALL RACEWAY AND EQUIPMENT SUPPORTS AND HANGERS SHALL BE ATTACHED TO STRUCTURAL MEMBERS.COORDINATE WITH STRUCTURAL DOCUMENTS.

DISCONNECT SWITCHES, MOTOR STARTERS, AND OTHER ELECTRICAL EQUIPMENT INSTALLED ABOVEACCESSIBLE CEILINGS AND REQUIRING ACCESS FOR MAINTENANCE, SHALL BE INSTALLED WITHBOTTOM OF DEVICE A MAXIMUM OF ONE (1) FOOT ABOVE CEILING TO PROVIDE READY ACCESSIBILITY.CODE AND MANUFACTURER REQUIRED CLEARANCES SHALL BE MAINTAINED.

ACCESS PANELS SHALL BE CONSOLIDATED TO MINIMIZE THE QUANTITY REQUIRED. COORDINATELOCATION WITH ARCHITECTURAL DOCUMENTS. THE PROPOSED LOCATION OF ACCESS PANELS SHALL BESUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION.

ALL CIRCUIT SHALL BE 2#12,1#12G,3/4"C UNLESS NOTED OTHERWISE.

PRIOR TO THE PANELBOARD ORDERING PROCESS, CONTRACTOR SHALL OBTAIN THE ACTUAL MAXIMUMAVAILABLE FAULT CURRENT DATA FROM THE UTILITY COMPANY AND PROVIDE FAULT CURRENT ANALYSISFOR THE FACILITY ELECTRICAL SYSTEM. AIC RATING FOR SWITCHBOARD AND PANELBOARD SHALL BEREVISED TO BE ABLE TO SUSTAIN THE FAULT CURRENT FOUND BY THE FAULT CURRENT ANALYSIS.

SERIES RATED PANELBOARDS AND BREAKERS ARE PROHIBITED.

PROVIDE STARTERS AND DISCONNECTS FOR ALL MECHANICAL AND PLUMBING MOTORS AND EQUIPMENTWITH MOTORS, UNLESS STARTERS ARE PROVIDED BY MANUFACTURER OF EQUIPMENT. SIZE ALL STARTERSAND DISCONNECTS PER THE NATIONAL ELECTRICAL CODE.

ALL SYMBOLS INDICATED IN LEGEND(S) MAY NOT NECESSARILY BE USED ON THIS PROJECT.

WEATHER RESISTANTWR

GRAPHICS LEGEND

DESCRIPTION

CUT LINE

SHEET NUMBER

SHEET NUMBER

REVISION AREA

REVISION DELTA

DRAWING NUMBER

DRAWING NUMBER

COLUMN REFERENCE GRID

SYMBOL

E1.2

E1.2

1

1 DRAWING TITLE

SCALE:

#

#

AREA TO BEDETAILED

KEYNOTEX

17. FIRE ALARM SYSTEM DRAWINGS AND SPECIFICATIONS SHOW THE MINIMUM REQUIREMENTS; ANY OTHERDEVICES REQUIRED MUST BE PART OF THE GENERAL CONTRACTOR'S BID NECESSARY TO BRING THE SYSTEMTO LOCAL CODE REQUIREMENTS.

18. CREATE AND SUBMIT FIRE ALARM SHOP DRAWINGS TO LOCAL AUTHORITY FOR APPROVAL.

19. ALL LOW VOLTAGE SYSTEMS TO BE BY OWNER'S VENDOR. CONDUIT AND BOXES BY CONTRACTOR.

18" / � / �L�3MULTI VOICE DATA OUTLET, WALL / FLOOR / ABOVE COUNTER

20. ALL 90 BATTERY BALLASTS USED FOR EMERGENCY/EGRESS LIGHTING SHALL PROVIDE A MINIMUM OF 700 LUMENSPER FIXTURE.

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 2014�008

CHECKED BY: RKC

DATE: 07/16/2014

REVISIONS

DATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

404�4

34�9

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

AL

BE

RT

DE

SIG

NG

RO

UP

,LL

CP

rim

rose

Sch

ools

R

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E�0

LEGENDS, NOTES ANDABBREVIATIONS

Electrical Sheet List

Sheet Number Sheet Name

E�0 LEGENDS, NOTES AND ABBREVIATIONS

E�2 FLOOR PLAN � LIGHTING

E�3 FLOOR PLAN � POWER

E�4 RISER DIAGRAMS

E�5 SCHEDULES AND DETAILS

E�6 SPECIFICATIONS

12 CUBBIES

PU

T D

OW

N

WA

LL

CA

B.

WA

LL

CA

B.

SH

EL

F

TR

AN

SP

OR

T S

TG

.

WA

LL

CA

B.

16 CUBBIES

SH

EL

F

TR

AN

SP

OR

T S

TG

.

WA

LL

CA

B.

PU

T D

OW

N C

OU

NT

ER

SH

EL

FS

HE

LF

SHELF SHELF

14 CUBBIES16 CUBBIES

SH

EL

F

48" WALL CAB.48" WALL CAB.

SHELF

SH

EL

F

LA

TE

RA

LL

AT

ER

AL

DW

R

DWR

DWR

DW

R

8 CUBBIES 8 CUBBIES

FR

EE

ZE

RR

EF

RIG

.

8 CUBBIES

PU

T D

OW

N C

OU

NT

ER

8 CUBBIES

48

" WA

LL

CA

B.

36" WALL CAB. 36" WALL CAB.

3a 3b 3b 3a

OCOC

OC

OC

OC

OC

OC

OC

OC

OC OC

OC

OC

OC

OC

OC

3a 3b

OC

D D

3a3b3a3b

3a3b

OC

OC

3a3b

3b3a

OC

OC

OC

D

OC

3/OC

DR

3/OC

OC

A a

A b

AA

A b

A aA a

AX

A

A

A

AX a

A b

A a

A a

AX b

A b

A a

A

A a AX b A a

A b A a A b

A a AX b A a

A bA a

AX b A aA a

A b

A b A b

AX a

A b

A a

A aA bA a

A b

A aA bA a

A b AX a

A a AX b A a

RX

R

R

R

A a AX b

A b A a A b

A AX

R

R

D

D

DX

D

D DX

D D DX D

D DX D D

D

DX D

D

DX

D

D D D

DX D

D D

D

A

AX

X1

X1

CX

AX b

A a A b

D

D

D

DX

D DX D DX D DX D

DX D

CX

D

DX

CX

CX

AX aA b

A a

A b A a A b A a

CX

CX

CX

CX

ACX

DDXDDXDDXDDX

CX

CX

CX

CX

X1

X1

X1

X1

X1

X1 X1

X1

X1

X1

P1

P1

P1

P1

P1

SX

SX

SX SXSX

SX

A b

A a

B ! 49

B ! 51

B ! 51B ! 47

B ! 53

B ! 54

B ! 53

B ! 54

B ! 52

B ! 56

B ! 49

B ! 50

X1

X1JJ

B ! 6 B ! 7

2

1

(TYP. OF 4)

bcd

N

N

B ! 48

CX

B ! 55

a b

a b a b

a b

b a b a

a b

b a

ab

ba

a b

ab

a b

SX

a b

B ! 49

CLASSROOM C1 CLASSROOM C2

CLASSROOM D2CLASSROOM D1

TOILET #13

TOILET #10

TLT #12

TLT #11

STORAGE

TOILET #8

TOILET #9

GALLERY #2

CAR SEATSTORAGE

VESTIBULE

RECEPTION

OFFICE

TLT #2 WOMEN'S

TLT #1 MEN'S

CONF.

CLASSROOM EP1

WARMINGKITCHEN

CLASSROOM A2CLASSROOM A2CLASSROOM B1

CLASSROOM EP2CLASSROOM EP3

TOILET #4

TOILET #5

RESOURCE

STAFF

TOILET #7

TOILET #6

TOILET #3

LAUNDRY

GALLERY #1

GA

LLE

RY

#3

GA

LLE

RY

#4

XN XNXN

XN

XN

XN XNXN XNXN XNXN XNXNXN

XNXN

XP

XN

XP XP

XNXN

XT

XP

XN

XPXPXP

XN

XN

B ! 57

a b

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 2014!008

CHECKED BY: RKC

DATE: 07/16/2014

REVISIONS

DATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

404!4

34!9

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

AL

BE

RT

DE

SIG

NG

RO

UP

,LL

CP

rim

rose

Sch

ools

R

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E!2

FLOOR PLAN ! LIGHTING

1/8" = 1'!0"E!2

1 FLOOR PLAN ! 1ST FLOOR ELECTRICAL LIGHTING

KEYNOTES: X

SHEETNOTES:1 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES.

2 REFER TO DRAWING E!0 FOR LIGHTING FIXTURE SCHEDULES.

3 REFER TO DRAWING E!5 FOR PANELBOARD SCHEDULES.

4 ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE PROVIDED WITH 90 MINUTE BATTERYBACKUP. LIGHTING FIXTURE IDENTIFICATIONS THAT END WITH "X" ARE EMERGENCY LIGHTINGFIXTURE TYPE. CIRCUIT BATTERY BALLAST AND EXIT SIGNS TO UNSWITCHED PORTION OF CIRCUITINDICATED.

5 ALL EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES SHALL BE CONNECTED TO THE SAME CIRCUITAS THE NORMAL LIGHT FOR THE AREA OF ROOM BEING SERVED. PROVIDE CONNECTION TOUNSWITCHED PORTION OF CIRUIT FOR VOLTAGE SENSING AND BATTERY CHARGING. PROVIDE FAILSAFE RELAY SO AS IN THE EVENT OF NORMAL POWER LOSS OR EMERGENCY SITUATION, LIGHT WILLBE TURNED ON REGARDLESS OF CONTROL SWITCH POSITION.

6 ALL EXTERIOR LIGHTING SHALL BE AUTOMATICALLY CONTROLLED VIA TIME CLOCK/PHOTOCELL ORTHROUGH LIGHTING CONTROL PANEL SPECIFIED BY LIGHTING DESIGNER.

7 ALL INTERIOR LIGHTING CIRCUITS SHALL BE ROUTED THROUGH RELAY PANEL XXX. REFER TO POWERPLANS FOR LOCATION.

8 EXISTING EXTERIOR DOWNLIGHTS TO REMAIN. EC SHALL VERIFY FIXTURE IS IN WORKING ORDER,REPLACE AS REQUIRED. CLEAN AND RELAMP FIXTURES. CONNECT TO SWITCH "b" LOCATED INOFFICE FOR CONTROLS.

9 EXISTING PARKING POLE LIGHTING TO REMAIN. PROVIDE 3 CIRCUITS A!58,59 AND 60.

1 OFFICE LIGHTS SHALL BE AS FOLLOWS: SWITCH "b" IF FOR OUTSIDE LIGHTOVERRIDE, SWITCH "c" IS FOR SIGN AND EMBLEM OVERRIDE, SWITCH "d" IS FOR LOTLIGHTS OVERRIDE. PERMENANTLY LABEL SWITCHES.

2 LIGHTING FOR WARMING KITCHEN NEEDS TO BE GASKETED.

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION LAMP WATTAGE VOLTAGE MOUNTING TYPE COMMENTS

A 2' X 4', RECESSED VOLUMETRIC FLUORESCENT, T5 LAMPS,ELECTRONIC BALLAST

(2) FP28 3500K 96W 120 V GRIDRECESSED

AX 2' X 4', RECESSED VOLUMETRIC FLUORESCENT, T5 LAMPS,ELECTRONIC BALLAST. 90 MINUTE EMERGENCY BALLAST.

(2) FP28 3500K 56W 120 V GRIDRECESSED

CX RECESSED NOM 1'X1' VOLUMETRIC CFL, ELECTRONIC BALLASTWITH EMERGENCY BALLAST.

(1) 32w TRT 3500 32W 120 V RECESSEDLAY!IN ORDRYWALL

D 6" (NOM.) SQUARE RECESSED CFL DOWNLIGHT, CLEARREFLECTOR, SELF!FLANGED, CONCENTRIC LENS

(1) 32TRT 3500K 32W 120 V RECESSED

DX 6" (NOM.) SQUARE RECESSED CFL DOWNLIGHT, CLEARREFLECTOR, SELF!FLANGED, CONCENTRIC LENS. 90 MINUTEEMERGENCY BALLAST.

(1) 32TRT 3500K 32W 120 V RECESSED

J 4' UNDERCABINET LIGHT (1) FP28/835 28W 120 V UNDERCABINET

N 6" RECESSED COMPACT FLUORESCENT DOWNLIGHT, CLEARREFLECTOR

(1) 26DTT 26 W 120 V RECESSED

P1 3" DIA. PENDANT, HARVEST WHITE, LINEN BOTTOM. (4) CF 26TT/835 104W 120 V PENDANTCEILING

POLELIGHTS

R 4' SURFACE MOUNTED WRAPAROUND FLUORESCENT, T5LAMPS, ELECTRONIC BALLAST.

(4) FP28/835 112W 120 V SURFACE

RE 4' SURFACE MOUNTED WRAPAROUND FLUORESCENT, T5LAMPS, ELECTRONIC BALLAST. 90 MINUTE EMERGENCYBALLAST.

(4) FP28/835 112W 120 V SURFACE

SX SCONCE EXIT DISCHARGE REMOTE EMERGE. 90 MINUTEEMERGENCY BALLAST.

42W CF 42W 120 V SURFACE EXTERIOR WALL MOUNTEDSCONCE WITH 90 MINUTEBATTERY BALLAST.

X1 SELF CONTAINED EMERGENCY LIGHT FIXTURE, EDGE LIT TYPE,SINGLE FACE (X2 DOUBLE FACE).

LED 5W 120 V SURFACE

XN EXISTING COMPACT FLUORESCENT DOWNLIGHT TO REMAIN. (1) 26DTT 26 W 120 V RECESSED

XP EXISTING SURFACE MOUNTED EXTERIOR FIXTURE. (1) CF 26TT/835 26W 120 V SURFACE

XT EXISTING 2 HEAD, DAMP LOCATION EMERGENCY FIXTURES. W/UNIT 22W 120 V SURFACE

0' 1' 4' 8' 16'

SCALE: 1/8" = 1'�0"

N

x;F

RE

EZ

ER

x;R

EF

RIG

.

12 CUBBIES

PU

T D

OW

N

WA

LL

CA

B.

WA

LL

CA

B.

SH

EL

F

TR

AN

SP

OR

T S

TG

.

WA

LL

CA

B.

16 CUBBIES

SH

EL

F

TR

AN

SP

OR

T S

TG

.

WA

LL

CA

B.

PU

T D

OW

N C

OU

NT

ER

SH

EL

FS

HE

LF

SHELF SHELF

14 CUBBIES16 CUBBIES

SH

EL

F

48" WALL CAB.48" WALL CAB.

SHELF

SH

EL

F

LA

TE

RA

LL

AT

ER

AL

DW

R

DWR

DWR

DW

R

8 CUBBIES 8 CUBBIES

F

F F

IC

IC

F

TV

J

J

FF

GF G

F

F F

F

F

GF

DC DC DC DC

DB

DC

DC

DC

DC

IC

IC

DB

IC

IMIC

IC

IC

IC

IC

ICF

JJ

J

GF

F

C TC

GF

GF

GF

GF

GF

GF

GF GF

GF

B

A

GF

GF

GF

.

1

2

3

4

5

6 7

8

9

10

11

1312

B & 46

B & 8

B & 2

B & 5

B & 6B & 7

B & 10

B & 42

B & 22

B & 24

B & 23

B & 16

B & 15B & 13

B & 26

B & 12B & 29

GFGF

B & 27

FACP

SECURITY

B & 31

B & 33

B & 35

B & 14

B & 19 B & 45

2

B & 37B & 39

14

15

16

17

B & 4

GFGF

B & 3

GF

GF

B & 40

GF18

B & 41,43

B & 30,32

B & 11

B & 18

B & 17

B & 21

B & 28

B & 20

B & 45

B & 9

B & 34,36

A & 32,34,36

WH&1

A & 38,40,42

WH&2

21 2421 24

21 24

21 24

24

19 20

CLASSROOM C1 CLASSROOM C2

CLASSROOM D2CLASSROOM D1

TOILET #13

TOILET #10

TLT #12

TLT #11

STORAGE

TOILET #8

TOILET #9

GALLERY #2

CAR SEATSTORAGEVESTIBULE

RECEPTION

TLT #2WOMEN'S

TLT #1 MEN'S

CLASSROOM EP1

WARMINGKITCHEN

CLASSROOM A2

CLASSROOM A2CLASSROOM B1

CLASSROOM EP2CLASSROOM EP3

TOILET #4

TOILET #5

RESOURCE

STAFF

TOILET #7

TOILET #6

TOILET #3

LAUNDRY

GALLERY #1

GA

LLE

RY

#3

OFFICE24

24

METER ANDCT CABINET

A & 14,16,18

CU&3A & 8,10,12

CU&2

A & 31,33,35

CU&7

A & 2,4,6

CU&1

A & 26,28,30

CU&6

A & 19,21,23

CU&5A

A & 20,22,24

CU&4

A & 15

FCU&7

A & 13

FCU&6

A & 9

FCU&5A

A & 7

FCU&4A & 5

FCU&3

A & 1

FCU&1

A & 3

FCU&2

B & 48

EF&18

B & 48

EF&1B & 49

EF&15

B & 49

EF&14

B & 51

EF&2

B & 51

EF&16

B & 51

EF&17

B & 51

EF&3

B & 52

TEF&B

B & 52

EF&4

B & 52

EF&5

B & 47

EF&12

B & 47

TEF&A

B & 50

EF&19

A & 25,27,29

CU&5B

A & 11

FCU&5B

B & 1

B & 53

EF&6

B & 53

EF&7

B & 54

EF&8

B & 54

EF&11B & 54

EF&10

B & 54

EF&9

GF

GF

GF

GF 4

4

4

FLUSHMOUNTED

SWITCH LOCATED AT TV CABINET

OFFICE

2 COMPUTERS

1 PRINTER

(5)

C&1

2 COMPUTERS

1 PRINTER

(8)

1 PDA

C&2

2 COMPUTERS

1 PRINTER

(5)

D&2

4 COMPUTERS

1 PRINTER

(8)

1 PDA

D&1

4 COMPUTERS

1 PRINTER

(8)

CONFERENCE

OFFICE PRINTER

OFFICE

RECEPTION

RECEPTION

(16)

CABLES FURNISHED ANDINSTALLED BY OWNER &TYP.

WIRE FURNISHED AND INSTALLEDBU CONTRACTOR WITH 6' MIN.SLACK. TERMINATIONSBYOWNER & TYP.

4

22

20

4

TYP.

24

TYP.

STAFF

RESOURCE

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 2014&008

CHECKED BY: RKC

DATE: 07/16/2014

REVISIONS

DATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

404&4

34&9

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

AL

BE

RT

DE

SIG

NG

RO

UP

,LL

CP

rim

rose

Sch

ools

R

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E&3

FLOOR PLAN & POWER

1/8" = 1'&0"E&3

1 FLOOR PLAN & 1ST FLOOR& ELECTRICAL POWER

KEYNOTES: XSHEETNOTES:

1 DEVICE LOCATIONS SHOWN ON THE PLAN SHALL BE PLACED EXACTLY AS SHOWN.COORDINATE WITH INT. ELEVATIONS SHEETS.

2 ALL ELECTRIC OUTLETS IN CLASSROOMS AND HALLWAYS SHALL BE INSTALLED 18"AFF TO TOP OF OUTLET ABOCE FLOOR UNLESS NOTED OTHERWISE.

3 ALL FIXTURES, WIRE AND ELECTRIC DEVICES SHALL BE U.L. APPROVED TYPE.

4 ALL OUTSIDE OUTLETS SHALL BE GROUND FAULT TYPE WITH WEATHER PROOFCOVER, MOUNT AT 24" A.F.G. UNLESS NOTED OTHERWISE.

5 ALARM PANEL AUTOMATIC CALL TYPE TO MEET NFPA 72&CURRENT EDITION.

6 ALL EMERGENCY ALARMS SHALL BE IN COMPLIANCE WITH MIN. DESIGN OF STYLEB.&NFPA 72&CURRENT EDITION.

7 MOUNT NON&FUSIBLE DISCONNECT SWITCH FOR CONDENSING UNITS AT 24" A.F.F.

8 ALL VISUAL AND AUDIO ALARMS SHALL COMPLY WITH SECTION 4.28, "ALARMS" OFTHE FEDERAL ADAAG.

9 ALL FGCI RECEPTACLES SHALL BE READILY ACCESSIBLE AND NOT INSTALLEDBEHIND EQUIPMENT OR APPLIANCES. COORDINATE WITH THE OWNER PRIOR TOINSTALLATION TO INSURE ACCESSIBILITY.

10 ALL RECEPTACLES IN CLASSROOM AREAS SHALL BE TAMPERPROOF TYPE.

1 WATER FOUNTAIN

2 PROVIDE CHIME AND TRANSFORMER FOR DOORBELL (NILES DB12).CIRCUIT TO A&5 USING 2#12,1#12G,3/4"C.

3 DOOR BELL PUSH BUTTON

4 NETWORK SWITCH & 5, 8, OR 16 PORT AS NOTED (UFOI) MOUNT TOCONCEALED UNDER DESK.

5 COPIER, PROVIDE 120V DEDICATED CIRCUIT, 2#12,1#12, 3/4"C

6 WASHER, PROVIDE 208V DEDICATED CIRCUIT, 2#12,1#12G, 3/4"C

7 DRYER, PROVIDE 208V, 30A, 2#10,1#10G,3/4"C

8 REFRIGERATOR, 120V, 2#12,1#12G, 3/4"C

9 FREEZER, 120V, 2#12,1#12G, 3/4"C

10 MICROWAVE, 208V, 30A, 2#10,1#10G,3/4"C

11 ICE MAKER, 120V, 2#12,1#12G, 3/4"C

12 SPRINKLER CONDENSER

13 IRRIGATION CONTROLS

14 PROVIDE CONDUIT BETWEEN J&BOX AT TV AREA IN LOBBY ANDRECEPTION DESK.

15 CONNECTION TO "G" LED TAPE LIGHT.

16 INTERCOM STATION @ 48" A.F.F.

17 INTERCOM MASTER STATION @ 48" A.F.F.

18 CONVECTION OVEN

19 PROVIDE JUNCTION BOX FOR CABLE TV @42" AFF. RUN 3/2" CONDUITWITH PULL STRING ABOVE CEILING.

20 WIRELESS ROUTER (OFOI). PROVIDE 2" CONDUIT ABOVE CEILING WITHCABLE OR CAT5 OR 6 WIRE PER OWNER'S INTERNET PROVIDERS POINTOF ENTRY. TERMINATE WITH 2" ELBOW AT 72" AFF BEHIND TV CABINET.PROVIDE DUPLEX OUTLET.

21 POA (UFOI) IN UPPER CABINET. PROVIDE DUPLEX OUTLET ANDNETWORK/JACK FACEPLATE WITH CAT5 OR 6 WIRE IN 3/4" CONDUIT TOABOVE CEILING&RUN TO SWITCH.

22 POINT OF ENTRY FOR CABLE OR PHONE (DSL). VERIFY EXACTLOCATION IN FIELD.

23 ALTERNATE POINT OF ENTRY FOR CABLE OR PHONE (DSL). (NOTINDICATED ON DRAWING. VERIFY IN FIELD).

24 NETWORK FACEPLATE AT 18" AFFF WITH HOLE(S) FOR CT5 OR 6 WIRE.RUN 3/4" CONDUIT TO ABOVE CEILING INSTALLATION. PROVIDE WIRE TOPOINT DESIGNATED ON PLAN. LEAVE MINIMUM 6' SLACK BOTH ENDS.END CONNECTIONS O.F.O.I. RUN ALL WIRE IN NEAT MANNER. DO NOTBLOCK ANY WALKWAYS OR PATHS.

N.T.S.E&3

2 NETWORK SCHEMATIC WIRING DIAGRAM

N

0' 1' 4' 8' 16'

SCALE: 1/8" = 1'�0"

TGRADE

4#600KCMIL IN 4"C, TYPE XHHW

CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALLPOWER DISTRIBUTION BLOCKS, OVERSIZED LUGS, ADDITIONALWIRE BENDING SPACE IN PANELBOARD ENCLOSURES, ETCREQUIRED TO TERMINATE THE ELECTRICAL FEEDERS TOELECTRICAL EQUIPMENT AS SHOWN AND FALLS UNDERCONTRACTOR MEANS AND METHODS. INSTALLATION SHALLBE UL LISTED, APPROVED BY THE DISTRIBUTION EQUIPMENTMANUFACTURER AND THE AUTHORITY HAVING JURISDICTION.

REFER TO 3/E%5 FORMORE INF0RMATION

EXISTING UTILITYTRANSFORMERTO REMAIN.COORDINATE REQUIREMENTSWITH UTILITY.PANEL A

208Y/120V400A BUS

4#600KCMIL, 1#2G, 4"C, TYPEXHHW

400A

1%1/2"C

CT CABINET

4#3/0,1#6G,2"C

PANEL B208/120V250A BUS

TAMPER SWITCHES ATBACK FLOW PREVENTER.REFER TO FP DRAWINGSFOR EXACT LOCATION.

FACP

NOTE:

REFER TO GENERAL NOTES 17 & 18 ON SHEET E%0

FOR ADDITIONAL FIRE ALARM REQUIREMENTS.

F F F

FFF

T F

TT

F

SEE POWER PLAN FOR QUANTITY AND LOCATION DEVICES.

1.

2.

NOT ALL DEVICES SHOWN FOR CLARITY.3.

ALARM

TROUBLE

ALARM

TROUBLE

ALARM

TROUBLE

TROUBLE

ALARM

ALARM

TROUBLE

TROUBLE

ALARM

AU

DIB

LE

AN

D V

ISU

AL

AL

AR

M (

PR

ER

EC

OR

DE

D V

OIC

E M

ES

SA

GE

, O

VE

RR

IDE

BA

CK

BR

OU

ND

MU

SIC

) A

ND

FIR

E D

EP

AR

TM

EN

T N

OT

IFIC

AT

ION

SU

PE

RV

ISO

RY

ALA

RM

AN

D L

IGH

T IN

FA

CP

AN

D C

EN

TR

AL S

TA

TIO

N N

OT

IFIC

AT

ION

.(O

VE

RR

IDE

AL

L B

AC

KG

RO

UN

D M

US

IC.)

DIS

PL

AY

ME

SS

AG

E A

T F

IRE

AL

AR

M A

NN

UN

CIA

TO

R P

AN

EL

TROUBLE

ALARM

TR

OU

BL

E A

LA

RM

AN

D L

IGH

T IN

FA

CP

FIRE ALARM OPERATING SEQUENCE SCHEDULE

UN

LO

CK

DO

OR

HIS

TO

RIC

AL

LO

G

FA

N S

HU

TD

OW

N

SPRINKLER TAMPER SWITCHES

FCU DUCT DETECTORS(SUPPLY AIR DUCT)

SPRINKLER ALARM PRESSURE SWITCHES

SPRINKLER WATER FLOW SWITCHES

FCU DUCT DETECTORS(RETURN AIR DUCT)

MANUAL PULL STATIONS

FAULT IN MONITORING CIRCUITOR COMPONENT

SMOKE DETECTORS

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 2014%008

CHECKED BY: RKC

DATE: 07/16/2014

REVISIONS

DATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

404%4

34%9

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

ALBERTDESIGNGROUP,LLC

Pri

mro

se S

choo

lsR

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E%4

RISER DIAGRAMS

N.T.S.E%4

1 ONE%LINE DIAGRAM

N.T.S.E%4

2 FIRE ALARM ONE%LINE DIAGRAM

N.T.S.E%4

3 FIRE ALARM SEQUENCE

3/0 COPPER

CONDUCTOR

ELECTRODE

FROM FOUNDATION LINE (MIN.)

GROUND ROD 3/4 " X 10'�0"TO BE 2'�0" AWAY

FINISHED GRADE

EXOTHERMICALLY WELDED

(MIN

)

5'�0

"

PROVIDE 1/4" X 5 7/8" X 12" BAR, DRILLEDAND TAPPED AS REQUIRED.INSULATORS SHALL BE 2.7kV RATED.

COPPER GROUND BUS

INSULATORS

STAND�OFFBRACKETS

1.

DETAIL NOTES:

TO INTERIOR PIPINGSYSTEMS (COLD WATERAS APPLICABLE)

GENERAL NOTES:

2. LENGTH OF GROUND RODS DEPENDENT ON GROUNDRESISTANCE REQUIRED AND/OR SPECIFICATIONS.MINIMUM GROUND ROD TO BE 3/4" X 10'.

1. ALL GROUNDING CONDUCTORS ARE 3/0 COPPERUNLESS NOTED OTHERWISE.

3. ALL GROUNDING CABLES SHALL BE MINMUM 3/0,EXCEPT WHERE REQUIRED TO BE INCREASED INSIZE BY NEC ARTICLE 250.

UL�APPROVEDCLAMP

COLD WATERSERVICEENTRANCE

SUPPLYVALVEMETER

OR UNION SIDE

THE DEPTH OF ELECTRODE.

SEE NOTE 2

GROUNDING ELECTRODESSPACING TO BE TWICE

JUMPER

GROUND BUS

NOTE 3

TO SWITCHBOARDENCLOSURE

CADWELD

BUILDINGSTRUC. STEEL

3/0 TYPICAL

FOUNDATIONREENFORCINGSTEEL

NEC 250�50(a)

METAL PIPEMEETING

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 2014�008CHECKED BY: RKC

DATE: 07/16/2014

REVISIONSDATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

404�4

34�9

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

AL

BE

RT

DE

SIG

NG

RO

UP

,LL

CP

rim

rose

Sch

ools

R

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E�5

SCHEDULES ANDDETAILS

N.T.S.E�51 GROUND ROD DETAIL

N.T.S.E�52 GROUNDING BAR

N.T.S.E�54 NEUTRAL GROUNDING SYSTEM

KITCHEN EQUIPMENT SCHEDULE

UNIT DESCRIPTION WATTS FLA VOLTS POLES PANEL DIRECT PLUG CIRCUIT NUMBER CIRCUIT DESCRIPTION NOTES

FREEZER REACH IN 2DOOR

864 W 7.2 A 120 V 1 B No Yes 33 2#12, 1#12G, 3/4"C MANUFACTURER TRUE FOOD SERVICE EQUIPMENT INC.,T�49F

ICE MAKER 1800 W 15.0 A 120 V 1 B No Yes 14 2#12, 1#12G, 3/4"C SCOTSMAN #CU0515

MICROWAVE 4400 W 22.5 A 208 V 2 B No Yes 30,32 2#10, 1#10G, 3/4"C THE AMANA #RC30S

FRIDGE REACH IN 2 DOOR 1656 W 13.8 A 120 V 1 B No Yes 31 2#12, 1#12G, 3/4"C MANUFACTURER TRUE FOOD SERVICE EQUIPMENT INC.,T�35

CONVECTION OVEN 5600 W 23.3 A 208 V 2 B No Yes 41,43 2#10, 1#10G, 3/4"C CADCO MODEL# XAF�193

EX � Existing circuit.

LK � Provide with lockable breaker.

AFCI � Provide with Arc Fault Circuit Interrupt breaker.

GFCI � Provide with Ground Fault Circuit breaker.Notes Legend:

Power 18116 VA 18116 VA

Other 0 VA 0 VA

Motor 1600 VA 1600 VA Total Est. Demand: 150 A

Equipment 500 VA 500 VA Total Conn.: 158 A

HVAC 340 VA 340 VA Total Est. Demand: 53889 VA

Receptacle 22980 VA 16490 VA Total Conn. Load: 57010 VA

Lighting 13474 VA 16843 VA

Load Classification Connected Load Estimated Demand Panel Totals

Total Amps: 178 A 139 A 165 A

Total Load: 20940 VA 16653 VA 19378 VA

�� 83 SPACE �� �� 0 0 �� �� SPACE 84 ��

�� 81 SPACE �� �� 0 0 �� �� SPACE 82 ��

�� 79 SPACE �� �� 0 0 �� �� SPACE 80 ��

�� 77 SPACE �� �� 0 0 �� �� SPACE 78 ��

�� 75 SPACE �� �� 0 0 �� �� SPACE 76 ��

�� 73 SPACE �� �� 0 0 �� �� SPACE 74 ��

�� 71 SPARE 20 1 0 0 1 20 SPARE 72 ��

�� 69 SPARE 20 1 0 0 1 20 SPARE 70 ��

�� 67 SPARE 20 1 0 0 1 20 SPARE 68 ��

�� 65 SPARE 20 1 0 0 1 20 SPARE 66 ��

�� 63 SPARE 20 1 0 0 1 20 SPARE 64 ��

�� 61 SPARE 20 1 0 0 1 20 SPARE 62 ��

59 EXIST POLE LIGHTS 20 1 1600 1600 1 20 EXIST POLE LIGHTS 60

57 LTG � EXISTING EXTERIOR 20 1 800 1600 1 20 EXIST POLE LIGHTS 58

55 LTG � SPRINKLER RM 20 1 32 1262 1 20 LTG � GALLARIED AND... 56

53 LTG � CLASSROOM C1�C2 20 1 955 1355 1 20 LTG � CLASSROOM D1�D2 54

51 LTG � CLASSROOMS EP1�EP2 20 1 778 1115 1 20 LTG � RECEPT, OFFICE,... 52

49 LTG � CLASSROOMS A2 20 1 1203 357 1 20 LTG � CLASSROOM EP3 50

47 LTG�CLASSROOM EP3 20 1 515 541 1 20 LTG � CLASSROOM B 48

45 RCPT�HALLWAY 20 1 900 360 1 20 RCPT�TOILET 46

�� 43 �� �� �� 2800 360 1 20 RCPT�VEST/CONF 44

41 CONVECTION OVEN 30 2 2800 1440 1 20 RCPT�CLASSROOM D2 42

39 RCPT�HALLWAY 20 1 540 360 1 20 RCPT�TOILET 40

37 SECURITY 20 1 300 1440 1 25 FIRE SMOKE DAMPER 38

35 FACP 20 1 500 600 �� �� �� 36 ��

33 FREEZER 20 1 1320 600 2 20 DRYER 34

31 REFRIGERATOR 20 1 1656 1500 �� �� �� 32 ��

29 RCPT�IRRIGATION... 20 1 180 1500 2 30 MICROWAVE 30

27 WASHER 20 1 1200 600 1 20 SPRINKLER COMPRESSOR 28

25 COPIER 20 1 300 1000 1 20 WATER FOUNTAIN 26

23 RCPT� CLASSROOM C2 20 1 1080 720 1 20 RCPT�CLASSROOM C2 24

21 RCPT� CLASSROOM D2 20 1 720 720 1 20 RCPT� CLASSROOM D2 22

19 RCPT�CLASSROOM A2 20 1 540 900 1 20 RCPT�LAUNDRY/EP3 20

17 RCPT� CLASSROM C1 20 1 900 720 1 20 RCPT� CLASSROOM C1 18

15 RCPT�RECEPTION 20 1 360 540 1 20 RCPT�RECEPTION 16

13 RCPT�OFFICE 20 1 900 2400 1 20 ICE MAKER 14

11 RCPT� WARMING KITCHEN 20 1 360 1080 1 20 RCPT�CLASSROOM D1 12

9 RCPT� CLASSROOM EP1 20 1 1080 1080 1 20 RCPT�... 10

7 RCPT� CLASSROOM A2 20 1 1110 1080 1 20 RCPT�HALLWAY 8

5 RCPT� CLASSROOM A2 20 1 180 750 1 20 RCPT�CLASSROOM A2 6

3 RCPT�RESOURCE/STAFF 20 1 1320 660 1 20 RCPT�HALLWAY 4

1 RCPT�CLASSROOM B1 20 1 900 900 1 20 RCPT� CLASSROOM EP3 2

Notes CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes

Enclosure: Type 1

Mounting: Recessed Wires: 4 Mains Rating: 200 A

Supply From: A Phases: 3 Mains Type: MLO

Location: Volts: 120/208 Wye A.I.C. Rating: 22000

Branch Panel: B

EX � Existing circuit.

LK � Provide with lockable breaker.

AFCI � Provide with Arch Fault Circuit Interrupt breaker.

GFCI � Provide with Ground Fault Circuit Interrupt breaker.

Notes Legend:

Receptacle 22980 VA 16490 VA

Power 48116 VA 48116 VA

Other 0 VA 0 VA

Motor 1600 VA 1600 VA Total Est. Demand: 382 A

Lighting 13474 VA 16843 VA Total Conn.: 391 A

HVAC 22444 VA 22444 VA Total Est. Demand: 137645 VA

Equipment 500 VA 500 VA Total Conn. Load: 140766 VA

Cooling 31652 VA 31652 VA

Load Classification Connected Load Estimated Demand Panel Totals

Total Amps: 412 A 374 A 385 A

Total Load: 49278 VA 44938 VA 46067 VA

�� 41 �� �� �� 19181 5000 �� �� �� 42 ��

�� 39 �� �� �� 16504 5000 �� �� �� 40 ��

37 PANEL B 200 3 20843 5000 3 100 WH�2 38

�� 35 �� �� �� 1788 5000 �� �� �� 36 ��

�� 33 �� �� �� 1788 5000 �� �� �� 34 ��

31 CU�7 30 3 1788 5000 3 100 WH�1 32

�� 29 �� �� �� 1315 1776 �� �� �� 30 ��

�� 27 �� �� �� 1315 1776 �� �� �� 28 ��

25 CU�5B 20 3 1315 1776 3 30 CU�6 26

�� 23 �� �� �� 1315 2016 �� �� �� 24 ��

�� 21 �� �� �� 1315 2016 �� �� �� 22 ��

19 CU�5A 20 3 1315 2016 3 35 CU�4 20

�� 17 SPARE 20 1 0 2016 �� �� �� 18 ��

15 FCU�7 20 1 1548 2016 �� �� �� 16 ��

13 FCU�6 20 1 1548 2016 3 35 CU�3 14

11 FCU�5B 20 1 1548 1776 �� �� �� 12 ��

9 FCU�5A 20 1 1548 1776 �� �� �� 10 ��

7 FCU�4 20 1 1548 1776 3 30 CU�2 8

5 FCU�3 20 1 1548 1788 �� �� �� 6 ��

3 FCU�2 20 1 1548 1788 �� �� �� 4 ��

1 FCU�1 20 1 1548 1788 3 30 CU�1 2

Notes CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes

Enclosure: Type 3R MCB Rating: 400 A 100% RATEDMounting: Surfaced Wires: 4 Mains Rating: 400 A

Supply From: Phases: 3 Mains Type: MCB

Location: Volts: 120/208 Wye A.I.C. Rating: 42000

Branch Panel: A

ELEC � PLUMBING EQUIPMENT SCHEDULE (NOT IN USE)

UNIT NUMBER UNIT DESCRIPTION W TOTAL VA FLA VOLTAGE POLES PANEL CIRCUIT NUMBER CIRCUIT DESCRIPTION DISCONNECT STARTER NOTES

WH�1 WATER HEATER 15000 W 15000 VA 62.1 A 208 V 3 A 32,34,36 4#4, 1#8G, 1�1/4"C 100/3/1 N/A

WH�2 WATER HEATER 15000 W 15000 VA 62.1 A 208 V 3 A 38,40,42 4#4, 1#8G, 1�1/4"C 100/3/1 N/A

ELEC + MECHANICAL EQUIPMENT SCHEDULE

UNIT NUMBER HEATER W HP TOTAL VA FLA VOLTAGE POLES PANEL CIRCUIT NUMBER CIRCUIT DESCRIPTION DISCONNECT STARTER NOTES

CU�1 5832 W 1/5 5364 VA 14.9 A 208 V 3 A 2,4,6 3#10,1#10G,3/4"C 30/3/3R W/UNIT

CU�2 5832 W 1/5 5328 VA 14.8 A 208 V 3 A 8,10,12 3#10,1#10G,3/4"C 30/3/3R W/UNIT

CU�3 6804 W 1/5 6048 VA 16.8 A 208 V 3 A 14,16,18 3#8,1#10G,3/4"C 60/3/3R W/UNIT

CU�4 6804 W 1/5 6048 VA 16.8 A 208 V 3 A 20,22,24 3#8,1#10G,3/4"C 60/3/3R W/UNIT

CU�5A 4536 W 1/8 3946 VA 11.0 A 208 V 3 A 19,21,23 3#12,1#12G,3/4"C 30/3/3R W/UNIT

CU�5B 4536 W 1/8 3946 VA 11.0 A 208 V 3 A 25,27,29 3#12,1#12G,3/4"C 30/3/3R W/UNIT

CU�6 5832 W 1/5 5328 VA 14.8 A 208 V 3 A 26,28,30 3#10,1#10G,3/4"C 30/3/3R W/UNIT

CU�7 5832 W 1/5 5364 VA 14.9 A 208 V 3 A 31,33,35 3#10,1#10G,3/4"C 30/3/3R W/UNIT

FCU�1 0 W 3/4 1548 VA 12.9 A 120 V 1 A 1 2#12,1#12G,3/4"C $M W/UNIT

FCU�2 0 W 3/4 1548 VA 12.9 A 120 V 1 A 3 2#12,1#12G,3/4"C $M W/UNIT

FCU�3 0 W 3/4 1548 VA 12.9 A 120 V 1 A 5 2#12,1#12G,3/4"C $M W/UNIT

FCU�4 0 W 3/4 1548 VA 12.9 A 120 V 1 A 7 2#10,1#10G,3/4"C $M W/UNIT

FCU�5A 0 W 3/4 1548 VA 12.9 A 120 V 1 A 9 2#12,1#12G,3/4"C $M W/UNIT

FCU�5B 0 W 3/4 1548 VA 12.9 A 120 V 1 A 11 2#10,1#10G,3/4"C $M W/UNIT

FCU�6 0 W 3/4 1548 VA 12.9 A 120 V 1 A 13 2#10,1#10G,3/4"C $M W/UNIT

FCU�7 0 W 3/4 1548 VA 12.9 A 120 V 1 A 15 2#10,1#10G,3/4"C $M W/UNIT

TEF�A 0 W 1/18 120 VA 1.0 A 120 V 1 B 47 2#12,1#12G,3/4"C $M W/UNIT CIRCUIT W/ LIGHTS REFER TOPLAN

TEF�B 0 W 1/10 120 VA 1.0 A 120 V 1 B 52 2#12,1#12G,3/4"C $M W/UNIT CIRCUIT W/ LIGHTS REFER TOPLAN

ELECTRICAL SPECIFICATION

GENERAL

1.01 GENERAL REQUIREMENTS:

A. Work shall be in accordance with the latest editions of the National Electrical Code, State,

and local authorities having jurisdiction.

B. Material shall be new and have the Underwriters Laboratories (UL) label, or be listed by UL

for the intended use.

C. Pay for all required permits and inspection fees.

D. Submit shop drawings and samples where specifically requested, as4built drawings and

Operation and Maintenance Manual.

1.02 SCOPE:

A. Interior Work

1. Provide complete electrical systems for the following:

a. Lighting and power distribution.

b. Lighting Fixtures and control.

c. Convenience and special receptacles.

d. Empty raceway systems for Telephone and Data.

e. Wiring to Plumbing, Heating, Ventilating and Air Conditioning equipment.

C. Submittals

1. Include complete materials list of all items proposed to be furnished and installed.

2. Manufacturer's equipment specifications and other data required to demonstrate

compliance with the specified requirements.

1.03 PRODUCTS:

A. Conduit:

1. Provide new conduit and deliver to the site in standard lengths.

2. Galvanized Rigid Steel Conduit and Couplings: Hot4dipped galvanized or sherardized

inside and out, with galvanized threads. Provide insulated throat metallic bushings.

3. Electric Metallic Steel Tubing: Hot4dipped galvanized or sherardized on exterior

surface. Provide wrench compression type couplings and insulated throat

compression connectors.

4. Flexible Conduit: Manufactured from single strip steel, hot4dipped galvanized. Provide

insulated die4cast connectors with ridges that thread into the inside of the conduit to

ensure a force fit, as manufactured by D&H Electric Company or equal. Binding4screw

type connectors are not acceptable.

5. Liquidtight Flexible Conduit: Identical to flexible steel conduit but with overall polyvinyl

chloride plastic jacket. Provide insulating connectors, Appleton STN Series, or equal.

All liquidtight flexible conduit shall include in its construction a bonding conductor,

sized to NEC requirements, per its sized load.

6. Polyvinyl Chloride plastic conduit: PVC Schedule 40, with slip fittings and connectors.

7. Underground 4 PVC.

8. Underground elbows 4 GRS

9. Above ground 4 EMT.

B. Wire and Cable:

1. All wire and cable for lighting and power systems shall be soft4drawn annealed copper

with 98 percent conductivity, 6004volt insulation, unless otherwise noted. Aluminum

wire and cable will not be permitted unless approved by engineer in advance.

2. All wire and cable shall be new and manufactured not more than 12 months prior to

installation. Each coil or reel shall bear the UL label and shall be marked with AWG or

circular wire size, voltage rating, insulation type, type of stranding, (and shielding,

where applicable), manufacturer's name, trade name, month and year when

manufactured. Wire shall be marked continuously with insulation type, wire size and

voltage rating.

3. Minimum wire size used shall be #12 AWG, except control circuits may be #14 AWG.

4. Conductors for all auxiliary and communication systems shall be as indicated or as

recommended by the system equipment manufacturer.

5. Conductors No. 10 AWG and smaller shall be solid; No. 8 and larger shall be stranded.

6. Insulation shall be type THHN/THWN or XHHW, to suit installed condition per National

Electrical Code. Use type XHHW for service conductors, use type THHN/THWN for

other conductors.

7. Conductors installed in areas subjected to temperatures exceeding 60°C (140°F);

terminating in incandescent lighting fixtures and installed through or into housing

containing ballasts shall be type AVA.

8. For all sizes, conductors with mineral filled cross4linked thermosetting polyethylene

insulation, UL4type XHHW rated 75°C (167°F) in wet or dry locations may be used.

C. Outlet Boxes:

1. Provide all boxes necessary for proper installation of electrical work in compliance with

codes and regulations. Each box shall have the volume required by the National

Electrical Code for the number of conductors enclosed in the box.

2. Provide 14piece galvanized pressed steel knockout type boxes, minimum sized 4"

square by 141/2" deep, in all wall and ceiling

locations unless otherwise indicated or required.

3. Cast ferrous or aluminum boxes and fittings shall be of the threaded hub type with

integral end4stop when located in exterior or normally wet locations.

D. Pull Boxes:

1. Where pull boxes are indicated or required on walls, in ceilings and in dry locations,

provide boxes constructed of code4gage sheet steel finished with one coat of metal

primer and one coat of primer sealer.

2. Ceiling pull boxes shall be recessed or concealed unless otherwise noted. In finished

areas, paint exposed surfaces to match ceiling or wall decor.

E. Wiring Devices:

1. General: Wiring devices shall be of the molded composition type, specification grade,

rated at 125 volts, unless otherwise noted or specified. All devices shall be flush

mounted unless otherwise noted and with finish matching device plates. Local

switches shall have alternating current ratings equal to full nominal capacity whenever

handling tungsten filament or inductive loads. Switches for 120 volt circuits shall be

rated 20 amperes and of the quiet action type. All key type switches shall be keyed

identically. Receptacles shall be of the NEMA Standard configuration for each

application, using a horseshoe shaped grounding pole. Color of devices and plates

shall be as selected by Architect.

2. Receptacles: Provide types in accordance with NEMA Standard configuration as

shown and hereinafter specified.

a. Duplex receptacles for 1204volt, single4phase service shall be specification grade,

rated 20 amperes, 125 volt, back or side wired, urea4molded. Receptacles shall

be Hubbell No. BR20.

b. Double duplex (quadruplex) receptacles for 1204volt, single phase service to be

same as duplex receptacles with two duplex receptacles installed in one 4" x 4"

outlet box with one 24gang faceplate.

c. Single receptacles for 1204volt, 204ampere, 34wire service shall be similar to

duplex receptacles, Hubbell No. 1877.

d. Receptacles identified as "GFI" or “GF” shall be ground fault interrupter type, 20

amperes, 120 volt, Hubbell No. GF20.

3. Toggle Switches: Single pole, 34way and 44way.

a. 120 or 277 volt lighting switches shall be rated 20 amperes, 120/277 volts, A.C.,

Hubbell No. CSB120.

F. Device Plates:

1. Provide plates for all outlet boxes and fittings of all systems except at outlets where

fixture canopies are used.

3. Provide plates of noncombustible, mar4resistant thermosetting plastic, 0.1" thick and of

plain style unless otherwise indicated.

4. Provide galvanized steel plates with stainless steel screws in all electrical and

mechanical equipment rooms, utility rooms, unfinished areas, and on all indoor surface

mounted boxes, and exposed extension rings. Plates shall be square or rectangular,

and hot4dipped galvanized or sherardized.

5. In wet areas, weatherproof exposed locations, and areas subject to hosing down, use

individually gasketed stainless steel cover plates.

G. Terminal Cabinets:

1. Provide surface or recess mounted types of sizes as indicated, constructed of

code4gauge sheet steel with hinged, lockable doors.

H. Nameplates:

1. Provide a nameplate for each panelboard, terminal cabinet, backboard, individually

mounted circuit breaker or motor control, disconnect switch, pull box, control panel,

push4button station, contactor, relay, all spare conduit stub4ups, and for all other

control devices or major items of electrical equipment.

2. Provide laminated plastic nameplates engraved in minimum 1/4" (6.4 mm) high black

letters on white background to correspond with the designations on the Drawings.

3. Attach nameplates to equipment with rivets, nuts and bolts, or self tapping sheet metal

screws.

I.

Safety Switches:

1. Unless indicated otherwise, use only unfused type and use only for motor equipment

disconnects. Provide switches with the number of poles and the voltage, current, and

horsepower ratings as required. Provide externally operable, quick4make, quick4break

type with cover interlock and lockable in either the open or closed position. Unless

indicated otherwise, provide switches indoors in NEMA Type 1 enclosures; outdoors or

where indicated to be weatherproof provide NEMA Type 3R raintight enclosures.

Switches shall be heavy4duty type horsepower rated meeting NEMA Specifications.

J.

Molded Case Circuit Breakers:

1. Provide molded4case circuit breakers of frame sizes, trip ratings and RMS symmetrical

interrupting ratings indicated.

2. Circuit breakers shall have permanent thermal and instantaneous magnetic trip.

Operating handle shall be a trip4free, toggle4type operating mechanism with

quick4make, quick4break action and positive handle trip indication.

K.

Fuses:

1. Below 200 amperes: Class K1, 200,000 amperes interrupting capacity Bussman

"Limitron", Chase4Shawmut "Amp4Trap Form 600", or Economy "Econolim".

2. 200 & 400 amperes fuse: Class RK1 Dual4Element Time4Delay fuse.

L.

Panelboards:

1. Provide circuit breaker type, dead4front safety style panelboards, with protective

devices in quantities, ratings, types, as required. Include anti4turn solderless pressure

type main lug connectors approved for use with copper conductors. Panels shall be

suitable for connecting feeders at top or bottom of panel. Equip with copper bus bars

with not less than 984percent conductivity, and full

sized neutral bus, unless otherwise indicated. Provide suitable lugs on neutral bus for

outgoing feeders requiring neutral connections. Provide molded case main and branch

circuit breakers, with toggle handles that indicate when tripped.

2. Enclosures for all panelboards shall be fabricated by one manufacturer.

3. Provide feed4thru lugs and additional feed4thru gutter space as required.

4. Provide barriered space for mounting contactors and control devices with a hinged

door and lock, where shown or required.

5. Breakers serving loads comprised of large wattage incandescent lamps shall be

equipped with desensitized magnetic trip mechanisms which prevent tripping by

in4rush currents.

6. Provide approved handle ties for individual circuit breakers protecting each

ungrounded branch circuit conductor of multi4wire branch circuits.

7. Provide neatly typed circuit index cards, clearly and correctly identifying all circuits,

mounted in card holders, behind glass or heavy plastic on the inside of the panelboard

doors. Indexes shall accurately record all room numbers.

8. Electrical Code Compliance: Comply with applicable local code requirements of the

authority having jurisdiction and NEC Article 384 as applicable to installation, and

construction of electrical panelboards and enclosures.

9. UL Compliance: Comply with applicable requirements of UL 67 "Electric Panelboards"

and UL's 50, 869, 486A, 486B, and 1053 pertaining to panelboards, accessories and

enclosures. Provide panelboard units which are UL4listed and labeled.

10. NEMA Compliance: Comply with NEMA Standards Publication No. 250 "Enclosures

for Electrical Equipment (1000 Volts Maximum)", Publication No. PB 1 "Panelboards",

and Publication No. PB 1.1 "General Instructions for Proper Installation, Operation and

Maintenance of Panelboards Rated 600 Volts or Less".

11. Panelboards for supplying Tenant Units circuiting for equipment rated at 120 volts shall

be 120/208 volts, 3 phase, 4 wire.

M. Lighting Fixtures:

1. General: Provide recessed, surface and pendant4mounted lighting fixtures, complete

with lamps and ballasts.

2. Exterior Light Fixtures: Provide recessed or surface mounted fixtures on building as

indicated.

3. Fluorescent Lighting Fixtures:

a. In office spaces and finished areas, fixtures shall be low brightness recessed

type, 2'x2' or 2'x4', with either 2 or 3 lamps. Fixtures shall have parabolic4shaped

reflector cells of semi4specular anodized aluminum, formed from one piece

brushed finished material. Parabolic blades shall be rigid, completely closed at

the top by integral flanges designed for maximum reflectance.

b. In areas not requiring low brightness louvers, such as restrooms, fixtures shall be

similar to above except with acrylic lens. Provide lens constructed of 100 percent

virgin acrylic, 0.125" thick, with female conical prisms having 3/16" square base.

Minimum depth of prisms shall be 0.08". Cones shall run 45 degrees to the

parallel and perpendicular axis of the lens panel. Lenses shall be destaticized,

and of the one4piece type. Provide lenses as made by KSH Incorporated or equal.

4. Ballasts:

a. Fluorescent Ballasts: Provide electronic type with characteristics to suit the

lamps, with voltage rating as required by the circuit in which fixture is connected.

Provide ballasts with the following features:

(1) Type "P" 4 integral thermal protection.

(2) CBM certified by ETL.

(3) Power factor not less than 90 percent.

(4) Quietest sound rating commercially available for each type.

(5) Third harmonic content: Maximum 15%.

(6) Total harmonic content: Maximum 10%.

(7) Maximum crest factor: 1.7.

b. Manufacturers: Advance, Dual4Lite, Jefferson or Universal.

5. Lamps: Provide lamps for all fixtures as indicated on the drawings and as follows:

a. Fluorescent:

(1) In general, fluorescent lamps shall be energy saving type, rapid start, T48, or

compact type PL, to suit fixture type.

b. All lamps to meet the requirements of the 1992 Federal Energy Policy Act.

c. Manufacturer: General Electric, Phillips or Osram/Sylvania.

6. Lighting fixtures shall be as described by the lighting fixture schedule.

1.04 INSTALLATION:

All material and equipment shall be installed in accordance with approved

recommendations of the manufacturer and conforming to the Contract Documents. The

installation shall conform to the applicable codes, rules and regulations. The Drawings

indicate the extent and the general location and arrangement of equipment, conduit and

wiring.

A. Conduit and Raceway:

1. Run concealed wherever possible.

2. Route conduit to avoid drains, other gravity lines and all obstructions.

3. Keep conduit at least 12" from the coverings on hot water and steam pipes, at least

18" from the covering on flues and breechings, and at least 24" from radiant heaters.

4. Run conduit exposed to view parallel with or at right angles to structural members,

walls or surfaces of the building. Route exposed conduit to preserve headroom,

access space and work space.

5. Changes in direction of runs shall be made with symmetrical bends or cast metal

fitting. Field4made bends and offsets shall be made with an approved hickey or

conduit4bending machine. Bend radius shall be not less than allowed in the NEC.

Crushed or deformed raceways shall not be installed.

6. Raceways shall be securely supported and fastened in place with pipe straps, wall

brackets, hangers, threaded C4clamps/beam clamps with retainers and locknut, or

ceiling trapeze at intervals not exceeding 10 feet. Fastenings shall be by expansion

bolt on concrete or brick; by machine screws, welded threaded studs. Nail4type nylon

anchors or threaded studs driven in by a powder charge and provided with lock washer

and nuts may be used in lieu of expansion bolts or machine screws.

7. Above suspended ceiling, support conduit on or from the structure by using galvanized

clips or galvanized brackets designed for the purpose. Hanging of equipment from

channel will not be permitted.

8. In steel stud construction: Rigidly support conduit at maximum 4' intervals with

galvanized clips or galvanized brackets designed for that purpose. Use galvanized

steel hangers of the types made specifically for the purpose where required.

9. Provide seismic bracing for conduits 241/2" diameter and larger.

10. Minimum conduit size shall be 3/4".

11. All conduit containing wiring operating at 120 volts or higher shall contain a code sized

equipment ground conductor.

12. Conduit for underground services shall be PVC encased in concrete.

C. Conductors:

1. Make joints, splices, taps and connections for 6004volt conductors with solderless

connectors. Use only plated copper alloy connectors or lugs; aluminum connectors or

lugs are not acceptable.

a. For #10 AWG and smaller: use #M "Scotchlok" or Ideal "Super Nut".

b. For #8 AWG and larger: Use T&B "Lock4Tie" connectors, Burndy Versitaps and

heavy4duty connectors, or O.Z. solderless connectors.

2. Retighten all bolt type connectors 24 to 48 hours after initial installation and before

taping.

3. Tape all connections made with non4insulated type connectors with rubber4type, 141/2

times the thickness of the conductor insulation, then cover with Scotch No. 23 tape.

D. Lighting Fixtures:

1. Verify the ceiling condition for each fixture and provide fixture complete with proper

mounting accessories required for the ceiling condition in which the fixture is mounted.

2. Where fixtures are for lay4in mounting in an exposed runner type of ceiling, the

additional ceiling cross runners required for the fixtures will be provided as part of the

ceiling work. In such ceilings or similar, provide each fixture with clips (4 required) or

equivalent means to prevent the accidental disengagement of the fixtures from the

ceiling. Where fixtures in such ceilings are square or rectangular in shape, provide

each fixture with two (2) #12 AWG galvanized steel wires, at diagonally opposite

corners, and secure to the building structure.

E. Grounding:

1. All metallic enclosures and raceways shall be electrically grounded per NEC Article

250.

F. Tests:

1. General: In addition to tests required by other sections, perform or cause to be

performed, provide all tests specified for electrical work.

2. Operating Test: After the installation is completed, conduct an operating test.

Equipment shall be demonstrated to operate in accordance with the requirements

herein, and to the satisfaction of the Owner's representative. All tests shall be

performed in the presence of the Architect or his representative. The Contractor shall

furnish instruments and personnel required for the test.

G. Protection:

1. Protect materials before, during and after installation and protect installed work and

materials of all other trades.

H. Replacements:

1. In the event of damage, immediately make all repairs and replacements necessary for

the approval of the Architect and at no additional cost to the Owner.

I. Delivery and Storage:

1. Deliver all materials to the job site in their original unopened containers, where

applicable, with all labels intact and legible at time of use. Store in strict accordance

with the manufacturer's recommendations as approved by the Architect.

2. Provide safety sliding cover plate for electrical outlets less than or equal to 36" A.F.F. in classrooms,

corridors, and adult restrooms.

214029

P E

R M

I T

S

E T

. N

O T

R

E L

E A

S E

D F

O R

C

O N

S T

R U

C T

I O

N .

JOB NUMBER: 20144008

CHECKED BY: RKC

DATE: 07/16/2014

REVISIONS

DATE: DESCRIPTION:

PRIMROSE SCHOOL atCOLORADO STATION4300 E. WARREN AVE.DENVER, CO

PROJECT LOCATION:

40444

3449

531

| 6

83 D

AY

LIL

Y C

T. | A

CW

OR

TH

, G

A 3

0102

INF

O@

CA

LB

ER

TD

ES

IGN

.CO

M

ALBERTDESIGNGROUP,LLC

Pri

mro

se S

choo

lsR

R

The

Lea

der

in E

duca

tional

Child C

are

3660 C

edar

cres

t R

oad

, Acw

ort

h, G

A 3

0101

770 5

29 4

100

Copyri

ght

© 2

012. T

hes

e dra

win

gs

and t

he

des

ign r

epre

sente

d h

ereb

y a

re t

he

excl

usi

ve

pro

per

ty o

f P

rim

rose

Sch

ool

Fra

nch

isin

g C

o. R

epro

duct

ion o

r an

y u

se o

f th

ese

dra

win

gs

oth

er t

han

for

the

pro

ject

inte

nded

wit

hout

the

expre

ss w

ritt

enco

nse

nt

of

Pri

mro

se S

chool

Fra

nch

isin

g C

o. is

pro

hib

ited

. A

ny u

nau

thori

zed u

se w

ill

be

subje

ct t

o l

egal

act

ion.

E46

SPECIFICATIONS