58DLA/DLXCOMFORTt 80 DELUXE 4-WAY MULTIPOISEINDUCED-COMBUSION GAS FURNACEInput Capacities: 45,000 thru 155,000 Btuh
Product Data
A04040
THE CARRIER Comfortt 80 GASFURNACEThe 58DLA/DLX 4-way Multipoise Gas Furnaces offer deluxefeatures not found in other single-stage 80% gas furnaces. Carrier’sQuieTecht noise reduction system makes the Comfortt 80 anincredibly quiet induced-draft gas furnace. The exclusive CarrierMedia Cabinet provides an economic way to add high performanceair filtration to homes. The gas furnace control system provides adehumidification mode, a third motor speed selection forcontinuous fan operation selectable at the thermostat, and faultcode storage in the event of power outages. Applications are easywith 4-way multipoise design, through-the-furnace downflowventing, 13 different venting options, and a door designed for easyservice access. An inner blower door is provided for tighter sealingin sensitive applications. The 58DLA/DLX furnaces are approvedfor use with natural or propane gas, and the 58DLX is approved foruse in Low NOx Air Quality Management Districts.
STANDARD FEATURES— QuieTecht noise reduction system— SmartEvapt--Humidity control when using a
Thermidistat Control— Comfort Fant--adjustable constant fan speed from
the thermostat— High--Efficiency Media Filtration Cabinet included— Microprocessor based control center
LED diagnostics and self test featureStores fault codes during power outagesAdjustable heating air temperature riseAdjustable cooling airflowDehumidification selection for summer--time cooling
— 4--way Multipoise furnace, 13 vent applications— Compact design -- only 33--1/3 in. (846 mm) tall— Power Heatt Igniter— Draft safeguard switch to ensure proper furnace
venting— Insulated blower compartment— Inner door for tighter sealing— HYBRID HEATr Dual Fuel System compatible— All models are chimney friendly when used with
accessory vent kit— Twinning in Upflow, Downflow and Horizontal— Residential installations eligible for consumer
financing through the Retail Credit Program
2
A02169
HEAT EXCHANGERA02215
CONTROL BOARD
A02170
INDUCER BLOWER
MODEL NUMBER NOMENCLATURE
58DLA 045 100 08
58DLA Deluxe 4--Way Multipoise Nominal Cooling Size58DLX Low NOx version (Airflow at .5 e.s.p.)
(400 CFM per 12,000 Btuh)08---800 CFM12---1200 CFM14---1400 CFM16---1600 CFM
Input Capacity 20---2000 CFM045---44,000 Btuh 110---110,000 Btuh 22---2200 CFM070---66,000 Btuh 135---132,000 Btuh090---88,000 Btuh 155---154,000 Btuh Series Number
58DLA/DLX
3
FURNACE COMPONENTS
INDUCER MOTOR ASSEMBLY
PRESSURE SWITCH
FLUE COLLECTOR BOX
GAS VALVE
MANUAL RESET LIMIT SWITCHES
HOT SURFACE IGNITOR
CONTROL
RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR)
VENT ELBOW
MAIN LIMIT SWITCH (BEHIND GAS VALVE)
DRAFT SAFEGUARD SWITCH
GAS MANIFOLD
GAS BURNER
FLAME SENSOR
BLOWER DOOR SAFETY SWITCH
BLOWER AND MOTOR
*
A09031
*Elbow may be turned to a different position, depending on type of installation.
NOTE: The 58DLA/DLX Furnaces are factory shipped for use with natural gas. These furnaces can be field-convertedfor propane gas with a factory-authorized and listed accessory conversion kit.
58DLA/DLX
4
CARRIER ACCESSORIES
CONTROLS:THERMOSTATSAND ZONING
Available in programmable andnon-programmable models, Carrierthermostats maintain a constanttemperature level in the home.For the ultimate in home comfort,Carrier’s 2, 4, and 8-zone systemsallow temperature control ofindividual “zones” of the home.This is accomplished through aseries of electronic dampers andremote room sensors. The 4-zonesystem is shown.
A97432
MECHANICALOR ELECTRONICAIR CLEANER
Cleans the air of smoke, dirt, andmany pollens commonly found.Saves decorating and cleaningexpenses by keeping carpets,furniture, and drapes cleaner.Electronic air cleaner is shown.
C04008A01484
MODEL HUMCCLFPHUMIDIFIER
By adding moisture to winter-dryair, a Carrier humidifier can oftenimprove comfort and keepfurniture, rugs, and draperies inbetter condition. Moisturizinghousehold air also helps to retainnormal body heat and providescomfort at lower temperatures.
Accessories
ELECTRONIC AIR CLEANER (EAC) Model EACB
MECHANICAL AIR CLEANER Models EZXCAB, FILCAB
HUMIDIFIER Model HUM
HEAT RECOVERY VENTILATOR Model HRV
ENERGY RECOVERY VENTILATOR Model ERV
UV LIGHTS Model UVL
THERMOSTAT ---NON-PROGRAMMABLE
For use with 1-speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NAC, TC---NAC
For use with 1-speed Heat Pump --- deg. F/C, Auto Changeover --- TP---NHP, TC---NHP*
For use with 2-speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NRH*
For use with multi-use / stage configurations --- deg. F/C, Auto Changeover/Temperature and HumidityControl --- TP---PRH{
THERMOSTAT ---PROGRAMMABLE
For use with 1-speed Air Conditioner --- deg. F/C, Auto Changeover, 7-Day Programmable ---TP---PAC
For use with 1-speed Heat Pump --- deg. F/C, Auto Changeover, 7-Day Programmable ---TP---PHP*
For use with 2-speed Air Conditioner --- deg. F/C, Auto Chaongeover, 7-Day Programmable ---TP---PRH*
For use with 1-speed Air Conditioner --- deg. F/C, 5---2 Day Programmable --- TP---PAC
For use with multi-stage applications --- deg. F/C, Auto Changeover, 7-Day Programmable --- TC---PHP}
For multi-use / stage configurations --- deg. F/C, Auto Changeover, 7-Day Programmable/Temperature andHumidity Control ---TP---PRH{
ZONING CONTROL
Comfort™ Series 3-Zone Kit --- ZONECC3ZAC01, ZONECC3ZHP01
2 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC2KIT01---B
4 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC4KIT01---B
8 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC8KIT01---B
* Model HP and 2S thermostat must be field converted to air conditioner operation.† Thermidistat Control can be configured for multiple use and staging, it must be configured for each specific application.
} Dual Fuel thermostat is used with furnace and heat pump application.
58DLA/DLX
5
CARRIER ACCESSORIES
DESCRIPTION58DLA/DLX
PART NO. 045-08
045-12
070-08
070-12
070-16
090-14
090-16
090-20
110-12
110-16
110-22
135-16
135-22
155-20
Cartridge Media Filter
FILCCCAR0016 X X X X X X X
FILCCCAR0020 X X X X X
FILCCCAR0024 X X
EZ Flex Media Filter with End Caps
EXPXXUNV0016 X X X X X X X
EXPXXUNV0020 X X X X X
EXPXXUNV0024 X X
Replacement EZ Flex Filter Media
EXPXXFIL0016 X X X X X X X
EXPXXFIL0020 X X X X X
EXPXXFIL0024 X X
External Bottom Return Filter Rack
KGAFR0401B14 X X X X
KGAFR0501B17 X X X
KGAFR0601B21 X X X X X
KGAFR0701B24 X X
External Side Return Filter Rack KGAFR0801SRE X X X X X X X X X X X X X X
Unframed Filter 3/4-in. (19 mm)
KGAWF1301UFR† X X X X X X X
KGAWF1401UFR X X X X X
KGAWF1501UFR X X
KGAWF1306UFR† X X X X X X X
KGAWF1406UFR X X X X X
KGAWF1506UFR X X
Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X
Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X
Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X
Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X
Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X
Chimney Adapter KitKGACA02014FC X X X X X X X X X X X
KGACA02015FC X X X
Natural-to-Propane Conversion Kit* KGANP4601ALL X X X X X X X X X X X X X X
Propane-to-Natural Conversion Kit KGAPN3901ALL X X X X X X X X X X X X X X
Label Kit KGALB0101KIT X X X X X X X X X X X X X X
Air Leakage Kit (Qty 10) KGBAC0110DGK X X X X X X X X X X X X X X
Gas Orifice Kit (Qty 50)
KGAHA0150N42
See Installation Instructions for model,altitude, and heat value usages.
KGAHA0250N43(factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA5750125
KGAHA5750130
KGAHA0850P56
* Factory-authorized and field installed. Fuel conversion kits are AGA/CGA recognized.† Suitable for Side Return Filter Rack (KGAFR0801SRE)X = AccessoryS = Standard
58DLA/DLX
6
PHYSICAL DATA
UNIT SIZE
045 070 090
08 12 08 12 16 14 16
OUTPUT CAPACITY BTUH*(Nonweatherized ICS) †
58DLX Upflow; all 58DLA 35,000 36,000 53,000 54,000 53,000 71,000 71,000
58DLX Downflow/Horizontal 34,000 34,000 51,000 51,000 51,000 68,000 68,000
INPUT BTUH*58DLX Upflow; all 58DLA 44,000 44,000 66,000 66,000 66,000 88,000 88,000
58DLX Downflow/Horizontal 42,000 42,000 63,000 63,000 63,000 84,000 84,000
AFUE%* Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0 80.0
SHIPPING WEIGHT --- LB (KG) 104 (47) 107 (49) 111 (50) 115 (52) 126 (57) 127 (58) 140 (64)
CERTIFIED TEMP RISE RANGE --- ° F (° C) 30---60(17---33)
20---50(11---28)
40---70(22---39)
30---60(17---33)
25---55(14---30)
40---70(22---39)
30---60(17---33)
CERTIFIED EXT STATICPRESSURE
Heating 0.10 0.10 0.12 0.12 0.12 0.15 0.15
Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50
AIRFLOW CFM‡Heating 920 1250 720 1195 1450 1375 1505
Cooling 845 1160 900 1200 1530 1385 1720
LIMIT CONTROL SPST
HEATING BLOWER CONTROL Solid-State Time Operation
BURNERS (Monoport) 2 2 3 3 3 4 4
GAS CONNECTION SIZE 1/2---in. NPT
GAS VALVE (Redundant) Manufacturer White-Rodgers
Minimum Inlet Pressure (In. wc) 4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc) 13.6 (Natural Gas)
IGNITION DEVICE Hot Surface
* Gas input ratings are certified for elevations to 2000 ft.(610 M) In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. Refer to National Fuel Gas CodeNFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for eachreturn-air supply.
ICS — Isolated Combustion System
BLOWER PERFORMANCE DATA
UNIT SIZE
045 070 090
08 12 08 12 16 14 16
DIRECT---DRIVE MOTOR Hp (ECM) 1/5 1/3 1/5 1/3 1/2 1/3 1/2
MOTOR FULL LOAD AMPS 2.9 5.2 2.9 5.2 7.9 5.2 7.9
RPM (Nominal) 1075-3 1075-4 1075-3 1075-4 1075-4 1075-4 1075-4
BLOWER WHEEL DIAMETER X WIDTHS --- In. (mm) 10 x 6(254 x 152)
10 x 6(254 x 152)
10 x 6(254 x 152)
10 x 6(254 x 152)
11 x 8(279 x 203)
10 x 8(254 x 203)
10 x 10(254 x 254)
58DLA/DLX
7
PHYSICAL DATA
UNIT SIZE
090 110 135 155
20 12 16 22 16 22 20
OUTPUT CAPACITY BTUH*(Nonweatherized ICS) †
58DLX Upflow; all 58DLA 71,000 89,000 89,000 89,000 107,000 107,000 125,000
58DLX Downflow/Horizontal 68,000 85,000 85,000 85,000 102,000 102,000 119,000
INPUT BTUH*58DLX Upflow; all 58DLA 88,000 110,000 110,000 110,000 132,000 132,000 154,000
58DLX Downflow/Horizontal 84,000 105,000 105,000 105,000 126,000 126,000 147,000
AFUE%* Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0 80.0
SHIPPING WEIGHT --- LB (KG) 146 (66) 135 (61) 146 (66) 152 (69) 149 (68) 163 (74) 170 (77)
CERTIFIED TEMP RISE RANGE --- ° F (° C) 25---55(14---30)
50---80(28---44)
40---70(22---39)
30---60(17---33)
50---80(28---44)
40---70(22---39)
45---75(25---42)
CERTIFIED EXTSTATIC PRESSURE
Heating 0.15 0.20 0.20 0.20 0.20 0.20 0.20
Cooling 0.50 0.50 0.50 0.80 0.50 0.50 0.50
AIRFLOW CFM‡Heating High/Low 1990 1335 1515 1900 1525 1850 1790
Cooling 2025 1355 1680 2220 1710 2110 2230
LIMIT CONTROL SPST
HEATING BLOWER CONTROL Solid-State Time Operation
BURNERS (Monoport) 4 5 5 5 6 6 7
GAS CONNECTION SIZE 1/2---in. NPT
GAS VALVE (Redundant) Manufacturer White-Rodgers
Minimum Inlet Pressure (In. wc) 4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc) 13.6 (Natural Gas)
IGNITION DEVICE Hot Surface
* Gas input ratings are certified for elevations to 2000 ft.(610 M) In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. Refer to National Fuel Gas CodeNFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for eachreturn-air supply.
ICS — Isolated Combustion System
BLOWER PERFORMANCE DATA
UNIT SIZE
090 110 135 155
20 12 16 22 16 22 20
DIRECT-DRIVE MOTOR Hp (PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4
MOTOR FULL LOAD AMPS 11.1 5.2 7.9 11.1 7.9 11.1 11.1
RPM (Nominal) ---SPEEDS 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4
BLOWER WHEEL DIAMETER x WIDTHS --- In. (mm) 11 x 11(279 x 279)
10 x 8(254 x 203)
10 x 10(254 x 254)
11 x 11(279 x 279)
10 x 10(254 x 254
11 x 11(279 x 279)
11 x 11(279 x 279)
PSC---Permanent Split Capacitor
58DLA/DLX
8
A02058
SEE NOTES: 1,2,4,7,8,9UPFLOW
SEE NOTES: 1,2,3,4,7,8,9UPFLOW
SEE NOTES: 1,2,4,5,7,8,9DOWNFLOW
A02059 A02061
SEE NOTES:1,2,3,4,5,7,8,9DOWNFLOW
SEE NOTES: 1,2,3,4,5,7,8,9DOWNFLOW
SEE NOTES: 1,2,4,5,6,7,8,9DOWNFLOW
A02060 A02063 A02062
Venting Notes1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel GasCode (NFGC), ANSI Z223.1/NFPA 54. In Canada, latest edition of the National Standards of Canada, Natural Gasand Propane Installation Code (NSCNGPIC), CSA B149.1.
2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in. (127 mm) vent connectorrequired, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,except when KGAVG0101DFG is used in downflow position.
4. Type B vent where required, refer to Note 1.5. 4--- in. (102 mm) single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent GuardKit.
6. Accessory Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom ventconfiguration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit,KGACA02014FC and KGACA02015FC for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, space approximately 180°apart.
9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120°apart. Secure Type B vent connectors per vent connector manufacturer’s recommendations.
58DLA/DLX
9
HORIZONTAL RIGHTSEE NOTES 1,2,4,5,7,8,9
A02068
HORIZONTAL RIGHTSEE NOTES 1,2,4,7,8,9
A02069
HORIZONTAL RIGHTSEE NOTES 1,2,4,5,7,8,9
A02070
HORIZONTAL LEFTSEE NOTES 1,2,4,7,8,9
A02064HORIZONTAL LEFT
SEE NOTES 1,2,4,5,7,8,9
A02065
HORIZONTAL LEFTSEE NOTES 1,2,4,5,7,8,9
A02066HORIZONTAL LEFT
SEE NOTES 1,2,4,5,7,8,9
A02067
58DLA/DLX
10
AIR DELIVERY—CFM (With Filter)*
UNIT SIZERETURN-AIRSUPPLY SPEED
EXTERNAL STATIC PRESSURE (In. wc)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
045-08Bottomor
1 Side(s)
HighMed-HighMed-Low
1085920820
1035875775
975830730
915770680
845710620
770640555
675555470
565440360
390250190
195——
045-12
Bottomor
1 Side(s)
Low
HighMed-HighMed-Low1085
1450136012501055
1375130012101035
1305124011601035
122511751100990
114511151040945
10501040965885
955950885810
845850790715
705725670715
510575520435
070-08Bottomor
1 Side(s)
HighMed-HighMed-Low
1030835725
1010815700
980790675
945760645
900720600
845675555
775610475
680490390
490375300
335265—
070-12Bottomor
1 Side(s)
HighMed-HighMed-LowLow
1425132012001040
1375128011751030
1320124011451010
126512051105985
120011401050945
11251075990895
1035995920845
940905840765
830790725655
655620555505
070-16Bottomor
1 Side(s)
HighMed-HighMed-LowLow
1805163014601275
1740158514201250
1670153013851225
1600147013251195
1530140512801155
1445133012201105
1360125511551050
128011701080980
11801080995910
1075990910835
090-14Bottomor
1 Side(s)
HighMed-HighMed-LowLow
1650151513851205
1600148513601180
1535144013201160
1465138012601120
1385130011951065
1285122011201005
117511151025925
1055990915810
895830710630
645600565510
090-16Bottomor
1 Side(s)
HighMed-HighMed-LowLow
2060179015051225
1985176515051225
1915171514801220
1820164514401195
1720156013751155
1610147013001085
149013451190985
134011951045870
11351010890735
925820740620
090-20
BottomOnly
HighMed-HighMed-LowLow
2405222520201810
2310215519551765
2220208018801715
2130199518051645
2025189517301565
1920178516301480
1790167515351390
1660156514201280
1530142012751145
1350126011351005
Both Sidesor 1
Side & Bottom
HighMed-HighMed-LowLow
2530228519951770
2450221519451740
2365215019001700
2270207518401645
2165198517701575
2065189016851505
1940178016001415
1805166014801325
1670152513501190
1505136011801040
1 Side Only
HighMed-HighMed-LowLow
2475226019501730
2395219019101695
2300211018551650
2200203517951600
2090194017301535
1985184516501470
1865173515551385
1730162014451285
1585147513101165
1425132511501000
110---12Bottomor
1 Side(s)
HighMed-HighMed-LowLow
1625151013601195
1575147013351180
1515141512951155
1445135512501115
1355128511801065
126011851100980
11651070985860
990890810740
785725670605
595530475410
110---16Bottomor
1 Side(s)
HighMed-HighMed-LowLow
2035174515301270
1965171015151265
1880165014701235
1790156014001195
1680145013101130
1495134012151055
136512051095970
12151090990875
1075955830720
875750670600
* A filter is required for each return ---air supply. Airflow performance includes 3/4---in. (19 mm) washable filter media such as contained in factory---authorizedaccessory filter rack. To determine airflow performance without this fitler, assume an additional .1 available external static pressure.
— Indicates unstable operating conditions.
58DLA/DLX
11
AIR DELIVERY—CFM (With Filter)* continued
UNIT SIZERETURN-AIRSUPPLY SPEED
EXTERNAL STATIC PRESSURE (In. wc)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
110-22
BottomOnly
HighMed-HighMed-LowLow
2530223019201640
2470220519001650
2400216518801635
2320211018451510
2220203517951575
2115195017301520
2000185516501455
1865174015551375
1730161514601285
1590148513401170
Both Sidesor 1
Side & Bottom
HighMed-High
—2235
—2200
24152155
23502100
22502040
21451955
20151850
18751740
17151595
15601470
1 Side Only
HighMed-HighMed-LowLow
2540212517901515
2495212017951535
2430210517901535
2355206017651520
2265201017201490
2175194016501445
2065184015851390
1935173015001315
1785161513901225
1650148512801120
135-16Bottomor
Side(s)
HighMed-HighMed-LowLow
2090179015451325
2010175515251320
1930170515001295
1835164014501265
1710155013801210
1590146513151150
147013601215995
133512101005865
1025945855745
835785670540
135-22
BottomOnly
HighMed-HighMed-LowLow
2485219518801640
2400215018501635
2310209018201615
2215200017801585
2110192017151530
2000182516351465
1880172015401370
1725156514151255
1535140512901150
1355125511601040
Both Sidesor 1
Side & Bottom
HighMed-HighMed-LowLow
—218018801640
—214518501635
2385206018201615
2305201017801585
2195194517151530
2085186516351465
1960176515401370
1825166014151255
1670151512901150
1465132511601040
1 Side Only
HighMed-HighMed-LowLow
2320212518451640
2250206518251620
2155199517651580
2055191017101540
1970181516501485
1855171015701410
1725161014751330
1600149013701220
1450134012401080
128011751100960
155-20
BottomOnly
HighMed-HighMed-LowLow
2465211518001570
2430210517901565
2375207517701551
2305203017351525
2230198016951495
2110191016401445
2000183015701370
1865172514651270
1725159013451175
1545142512251070
Both Sidesor 1
Side & Bottom
HighMed-High
—2155
—2135
23752095
22852040
22001975
21051895
19951790
18701685
17301550
15701400
1 Side Only HighMed-High
—2140
—2095
22602040
21801975
20851890
19751810
18651705
17401595
16051480
14551325
* A filter is required for each return ---air supply. Airflow performance includes 3/4 in. (19 mm) washable filter media such as contained in factory---authorizedaccessory filter rack. To determine airflow performance without this fitler, assume an additional .1 available external static pressure.
— Indicates unstable operating conditions.
58DLA/DLX
12
DIMENSIONS
2-7/16"
1-1/8"
28-7/8" (733mm)
25-1/4"
22-9/16"
JUNCTION BOX LOCATION
7/8" DI A ACCESSORY 1/2" (13 mm) DIA.
THERMOSTAT WIRE ENTRY
3-15/16" (84mm)
LEFT HAND GAS ENTRY
33-5/16" 24-7/8"
5-1/2"
7/8" (22mm) DIA.ACCESSORY
11/16"
21-5/8" BOTTOM INLE T
1-11/16"
13/16"
11/16"
4-13/16"
AIRFLOW
19"
OUTLE T
13/16"
11/16" 8-9/16"
VENT OUTLE T 5 PLACES (TYP)
3-3/4"
1-3/4" DIA.RIGHT HAND GAS ENTRY
7/8" DIA. K.O. WIRE ENTRY
SIDE INLE T
14-7/8"
7/8" DIA. ACCESSORY
1-1/4"
1" 22-1/16"
A D
F
E
(FLUE COLLAR)
5-15/16"(135mm)
24" CASING
1-5/16"
1/2" DIA. K.O.THERMOSTAT WIRE ENTRY
ALTERNAT E JUNCTION BOX
LOCATIONS (TYP)
26-1/8"
1-1/2"
7-3/4" 9-5/8"
11-1/2"
5-1/2"
(664mm)
(641mm)
(573mm)
(22mm)
(846mm)
(17mm) (549mm)
(610mm)
(43mm)
(140mm)
(632mm)
(17mm)
(140mm)
(95mm)
(21mm) (122mm)
(217mm)
(62mm)
(33mm)
(29mm) (483mm)
(13mm)
(44mm)
(22mm)
(22mm)
(38mm) (560mm)
(25mm)
(32mm)
(378mm)
(17mm) (197mm) (244mm)
(292mm)
(21mm)
A04037
NOTES:1. Two additional 7/8---in. (22 mm) diameter holes are located in the top plate.2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12---in. (368 x 305 mm) rectangle.b. For 1200 CFM---20---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, acombination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
FURNACESIZE
ACABINETWIDTH
DSUPPLY---AIRWIDTHIN. (MM)
ERETURN---AIRWIDTHIN. (MM)
FCENTER LINETOP AND
BOTTOM FLUECOLLARIN. (MM)
FLUECOLLAR*IN. (MM)
SHIP WTLB (KG)
FILTERMEDIACABINETSIZEIN. (MM)
045---08 14---3/16 (360) 12---9/16 (319) 12---11/16 (322) 9---5/16 (237) 4 (102) 114 (52) 16 (406)
045---12 14---3/16 (360) 12---9/16 (319) 12---11/16 (322) 9---5/16 (237) 4 (102) 117 (53) 16 (406)
070---08 14---3/16 (360) 12---9/16 (319) 12---11/16 (322) 9---5/16 (237) 4 (102) 121 (55) 16 (406)
070---12 14---3/16 (360) 12---9/16 (319) 12---11/16 (322) 9---5/16 (237) 4 (102) 125 (57) 16 (406)
070---16 17---1/2 (445) 15---7/8 (403) 16---1/8 (410) 11---9/16 (294) 4 (102) 136 (62) 16 (406)
090---14 17---1/2 (445) 15---7/8 (403) 16---1/8 (410) 11---9/16 (294) 4 (102) 135 (61) 16 (406)
090---16 21 (533) 19---3/8 (492) 19---1/2 (495) 13---5/16 (338) 4 (102) 150 (68) 20 (508)
090---20 21 (533) 19---3/8 (492) 19---1/2 (495) 13---5/16 (338) 4 (102) 156 (71) 20 (508)
110---12 17---1/2 (445) 15---7/8 (403) 16---1/8 (410) 11---9/16 (294) 4 (102) 143 (65) 16 (406)
110---16 21 (533) 19---3/8 (492) 19---1/2 (495) 13---5/16 (338) 4 (102) 156 (71) 20 (508)
110---22 21 (533) 19---3/8 (492) 19---1/2 (495) 13---5/16 (338) 4 (102) 162 (73) 20 (508)
135---16 21 (533) 19---3/8 (492) 19---1/2 (495) 13---5/16 (338) 4 (102){ 159 (72) 20 (508)
135---22 24---1/2 (622) 22---7/8 (581) 23 (584) 15---1/16 (383) 4 (102){ 173 (78) 24 (610)
155---20 24---1/2 (622) 22---7/8 (581) 23 (584) 15---1/16 (383) 4 (102){ 180 (82) 24 (610)
* 5 in. or 6 in. (127 or 152 mm) vent connector may be required in some cases.
{ 135 and 155 size furnaces require 5---in. (127 mm) vents. Use a 4---5 in. (102---127 mm) vent adapter between furnace and vent stack.
58DLA/DLX
13
A
Media/Filter Cabinet A B C
16" (406 mm) 17" (432) 16 1/4"(413) 15" (381)
20" (508 mm) 21" (533) 20 1/4"(514) 19" (483)
24" (610 mm) 25" (635) 24 1/4"(616) 23" (584)
23 5/8"
23 3/8"
Furnace Side
23 3/4"
Centerline Screw Slots
25 5/8"
Duct Side
24 1/2"
With Flanges Bent Out23 1/8"
Opening
5 3/4"
C O
peningw
ith Flanges B
ent In
B
(600 mm)
(594 mm)
(603 mm)
(146 mm)
(651 mm)
(622 mm)
(587 mm)
A00444
A08471
EFFICIENCYRATINGCERTIFIED
MEETS DOE RESIDENTIAL CONSERVATIONSERVICES PROGRAM STANDARDS.
Before purchasing this appliance, read importantenergy cost and efficiency information availablefrom your retailer.
58DLA/DLX
14
TYPICAL WIRING SCHEMATIC
A99440
ELECTRICAL DATA
FURNACESIZE
VOLTS---HERTZ---PHASE
OPERATING VOLTAGERANGE MAXIMUM
UNIT AMPSUNIT
AMPACITY#
MAXIMUMWIRE
LENGTH FT.(M)‡
MAXIMUMFUSE ORCKT BKRAMPS†
MINIMUMWIREGAUGE
MAXIMUM* MINIMUM*
045---08 115---60---1 127 104 5.4 7.54 49 (15) 15 14
045---12 115---60---1 127 104 7.0 9.50 39 (12) 15 14
070---08 115---60---1 127 104 5.0 7.06 52 (16) 15 14
070---12 115---60---1 127 104 6.8 9.22 40 (12) 15 14
070---16 115---60---1 127 104 9.5 12.60 29 (9) 15 14
090---14 115---60---1 127 104 8.2 10.83 34 (10) 15 14
090---16 115---60---1 127 104 10.0 13.13 28 (9) 15 14
090---20 115---60---1 127 104 13.6 17.61 32 (8) 20 12
110---12 115---60---1 127 104 8.2 10.75 34 (10) 15 14
110---16 115---60---1 127 104 10.1 13.12 28 (9) 15 14
110---22 115---60---1 127 104 14.8 18.99 30 (9) 20 12
135---16 115---60---1 127 104 10.2 13.27 27 (8) 15 14
135---22 115---60---1 127 104 14.4 18.55 30 (9) 20 12
155---20 115---60---1 127 104 15.0 19.33 29 (9) 20 12* Permissible limits of the voltage range at which the unit operates satisfactorily.# Unit ampacity = 125 percent of largest operating component’s full load amps plus 100 percent of all other potential operating components’ (EAC, humidifier,etc.) full load amps.
{ Time---delay type is recommended.} Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
58DLA/DLX
15
TYPICAL INSTALLATION
CONDENSINGUNIT
AIRFLOW
ELECTRONICAIR CLEANER
GAS-FIREDWATER HEATER
HUMIDIFIER
A02184
58DLA/DLX
16
GUIDE SPECIFICATIONSGas Furnace58DLA/DLXGeneralSYSTEM DESCRIPTIONFurnish a _________________ fixed capacity gas--fired
furnace for use with natural gas or propane (factoryauthorized conversion kit required for propane); furnishcold air return plenum; furnish external medial cabinet foruse with accessory media filter or standard filter.QUALITY ASSURANCEUnit will be designed, tested and constructed to the
current ANSI Z 21.47/CSA 2.3 design standard forgas--fired central furnaces.Unit will be 3rd party certified by CSA to the current
ANSI Z 21.47/CSA 2.3 design standard for gas--firedcentral furnaces.Unit will carry the CSA Blue StarR and Blue FlameR
labels.Unit efficiency testing will be performed per the current
DOE test procedure as listed in the Federal Register.Unit will be certified for capacity and efficiency and
listed in the latest GAMA Consumer’s Directory ofCertified Efficiency Ratings.Unit shall carry the current Federal Trade Commission
Energy Guide efficiency label.DELIVERY, STORAGE AND HANDLINGUnit shall be shipped as single package only and is
stored and handled per unit manufacturer’srecommendations.WARRANTY (for inclusion by specifying engineer)U.S. and Canada only. Warranty certificate available
upon request.ProductsEQUIPMENTComponents shall include: slow-opening gas valve to
reduce ignition noise, regulate gas flow, with electricswitch gas shut--off; flame proving sensor, hot surfaceigniter, pressure switch assembly, flame rollout switch,blower and inducer assembly, 40va transformer;low--voltage (heating) (heating/cooling) thermostat.Blower Wheel and Blower MotorGalvanized blower wheel shall be centrifugal type,
statically and dynamically balanced. Blower motor of PSCtype shall be permanently lubricated with sealed bearings,of _______hp, and shall be multiple--speed direct drive.Blower motor shall be soft mounted to the blower scroll toreduce vibration transmission.FiltersFurnace may have reusable--type filters. Filter shall be
_______ (x) _______in. (mm). An accessory highefficiency Media Filter is available as an option._______________ Media Filter.CasingCasing shall be of .030 (.76 mm) in. thickness
minimum, pre--painted galvanized steel.Inducer MotorInducer motor shall be soft mounted to reduce vibration
transmission.Draft Safeguard SwitchDraft Safeguard Switch (blocked vent safeguard) shall
be factory installed to reduce the possibility of vent gasinfiltration due to a blocked or restricted vent pipe.
Heat ExchangersHeat exchangers shall be a 4-Pass 20 gage aluminized
steel of fold--and--crimp sectional design when appliedoperating under negative pressure.ControlsControl shall include a micro--processor based
integrated electronic control board with at least 11 servicetroubleshooting codes displayed via diagnostic flashingLED light on the control, a self--test feature that checks allmajor functions of the furnace within one minute, and areplaceable automotive--type circuit protection fuse.Multiple operational settings available including, separateblower speeds for heating, cooling, and continuous fan.Continuous fan speed may be adjusted from thethermostat. Cooling airflow will be selectable between 350or 400 CFM per ton of air conditioning. Features will alsoinclude temporary reduced airflow in the cooling mode forimproved dehumidification when a ThermidistatR isselected as the thermostat.OPERATING CHARACTERISTICSHeating Capacity shall be ________ Btuh input;
________ Btuh output capacity.Fuel Gas Efficiency shall be 80% AFUE. Air delivery
shall be ___________ cfm minimum at 0.50 in. wcexternal static pressure.Dimensions shall be: depth __________ in. (mm);
width _________ in (mm); height_________in. (mm)(casing only). Height shall be_________in.(mm) with A/Ccoil and _____________in. (mm) overall with plenum.ELECTRICAL REQUIREMENTSElectrical supply shall be 115 volts, 60 Hz,
single--phase (nominal). Minimum wire size shallbe_________AWG; maximum fuse size or circuit breakershall be __________Amps.SPECIAL FEATURESRefer to section of the product data sheet identifying
accessories and descriptions for specific features andavailable enhancements.
Copyright 2009 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 2/09
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: 58DL-6PD
Replaces: 58DL-5PD
58DLA/DLX