product application notes for series 9175/6/7 … export/supplier content/avx_478/pdf/avx_a… ·...

11
ELCO Engineering Specification ELCO EUROPE Compile Description Page Newmarket, Suffolk. Elco Europe (A division of AVX) Confidential Proprietary Copyright Elco Europe 2008 NCH 917X IDC Application Notes 1 England. CB8 0AT. Size Specification Number Issue Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1 PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 IDC WIRE TO BOARD CONNECTORS 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9175, 9176 and 9177 IDC connectors. 3. PRODUCTS 00-9175-00X-001-X06 - STANDARD IDC CONNECTOR 26-28AWG – see section 4 00-9176-00X-0XX-X06 - STANDARD IDC CONNECTOR 18-24AWG – see section 5 60/70-9176-001-5XX-XXX - SINGLE CONTACT IDC 18-24AWG – see section 6 00-9177-00X-0XX-X06 - STANDARD IDC CONNECTOR 14-20AWG – see section 7 Note: The connectors in the product series are available in standard black colour (white and other colours are special order). The colours used in this document are for illustration purposes only.

Upload: phungnhu

Post on 20-Apr-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 1

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 IDC WIRE TO BOARD CONNECTORS

1. SPECIFICATION DISTRIBUTION

No restrictions for issue

2. SCOPE

This specification contains the application notes for the 9175, 9176 and 9177 IDC connectors.

3. PRODUCTS 00-9175-00X-001-X06 - STANDARD IDC CONNECTOR 26-28AWG – see section 4 00-9176-00X-0XX-X06 - STANDARD IDC CONNECTOR 18-24AWG – see section 5 60/70-9176-001-5XX-XXX - SINGLE CONTACT IDC 18-24AWG – see section 6 00-9177-00X-0XX-X06 - STANDARD IDC CONNECTOR 14-20AWG – see section 7

Note: The connectors in the product series are available in standard black colour (white and other colours are special order). The colours used in this document are for illustration purposes only.

norman
norman
Page 2: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 2

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

4.0 9175 CONNECTOR 26-28AWG

4.1 9175 CONNECTOR

Available in 2way and 3way sizes for 26 and 28AWG wires.

4.2 9175 STANDARD HAND WIRE INSERTION TOOLING

Universal handle Plastic termination tool for low-medium volumes (metal versions available for higher volume) Maximum insulation diameter 1mm suitable for 26-28AWG wires

norman
norman
Page 3: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 3

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

4.3 9175 WIRE INSERTION METHOD – SINGLE WIRE BY HAND

Please note that the PCB should be supported directly under the wire being terminated.

1. Cut and position wire over contact slot

2. Locate end of tool over wire and align to slot in connector

3. Push down on tool until wire is pressed to bottom of slot

4. Remove tool from connector and wire

5. Repeat for all wires as necessary

norman
norman
Page 4: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 4

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

4.4 9175 MASS TERMINATION INSERTION TOOLING

Metal Insertion blocks for 2 & 3way connectors Maximum insulation diameter 1mm for 26 and 28AWG wires

4.5 9175 WIRE INSERTION METHOD – MASS TERMINATION

Please note that the PCB should be supported directly under the wires being terminated.

1. Cut and position wires to all contact slots

2. Locate mass termination block over wires and connector

3. Push down on termination block using a hand/air press

4. Remove block from connector and wires

norman
norman
Page 5: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 5

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

5.0 9176 CONNECTOR 18-24AWG

5.1 9176 CONNECTOR

Available in 1way, 2way and 3way sizes for 18 to 24AWG wires.

5.2 9176 STANDARD HAND WIRE INSERTION TOOLING

Universal handle

Plastic termination tool for low-medium volumes (metal versions available for higher volume) To suit insulation diameters up to 1.6mm and 2.1mm for 18 to 24AWG wires

norman
norman
Page 6: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 6

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

5.3 9176 WIRE INSERTION METHOD – SINGLE WIRE BY HAND

Please note that the PCB should be supported directly under the wires being terminated.

1. Cut wire and position over contact slot 2. Locate end of the tool over wire

and align with slot in connector

3. Push down on tool until wire is pushed down to bottom of slot

4. Remove tool from connector and repeat as necessary

norman
norman
Page 7: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 7

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

5.4 9176 MASS TERMINATION INSERTION TOOLING

Metal insertion blocks for 2 & 3way connectors To suit insulation diameters up to 1.6mm and 2.1mm for 18 to 24AWG wires

5.5 9176 WIRE INSERTION METHOD – MASS TERMINATION

Please note that the PCB should be supported directly under the wires being terminated.

1. Cut wires and position over contact slots 2. Locate the tool over the wires and align

with slots in connector

3. Push down on tool until wire is pushed down to bottom of slot

4. Remove block from connector and wires

norman
norman
Page 8: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 8

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

5.6 9176 CAP ACCESSORY

5.6 9176 CAP Available in 2way and 3way sizes 1.6mm and 2.1mm wire diameters for 18 to 24AWG wires.

5.7 9176 CAP ASSEMBLY

Please note that the PCB should be supported directly under the wires being terminated.

1. Push wires into cap slots (slots grip wires)

Through Slot Version Stop End Version

2. Offer the pre-assembled wire/cap assy above the

connector

3. Push down on cap until clips latch on the connector

norman
norman
Page 9: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 9

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

6.0 9176 SINGLE CONTACT IDC

6.1 9176 SINGLE CONTACT COMPONENTS Available as a single contact for 18 to 24AWG wires.

6.2 9176 SINGLE CONTACT IDC METHOD

Please note that the PCB should be supported directly under the wires being terminated.

1. Cut and locate wire to cap slot 2. Push wire into cap slot (slot grips wire)

3. Locate pre-loaded wire/cap to IDC contact 4. Push home cap to be flush

with board surface

norman
norman
Page 10: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 10

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

7.0 9177 CONNECTOR 14-20AWG

7.1 9177 CONNECTOR Available in 1way, 2way and 3way sizes for 14 to 20AWG wires.

7.1 9177 MASS TERMINATION TOOLS

Metal insertion blocks for 1, 2 & 3way connectors To suit insulation diameters up to 1.6mm and 2.1mm

norman
norman
Page 11: PRODUCT APPLICATION NOTES FOR SERIES 9175/6/7 … Export/Supplier Content/AVX_478/PDF/AVX_A… · ELCO Engineering Specification Compile Description Page ELCO EUROPE Newmarket, Suffolk

ELCO Engineering Specification

ELCO EUROPE Compile Description Page

Newmarket, Suffolk.

Elco Europe (A division of AVX) Confidential Proprietary

Copyright Elco Europe 2008 NCH 917X IDC Application Notes 11

England. CB8 0AT. Size Specification Number Issue

Copyright Elco Europe 102613 12-Jan-10 AV 201-01-124 A Form 106-01-178 Issue 1

10.2 9177 MASS WIRE TERMINATION METHOD

Please note that the PCB should be supported directly under the wires being terminated.

1. Cut wires and position over contact slots

2. Locate the tool over the wires and align with slots in connector

3. Push down on tool until wire is pushed down to bottom of slot 4. Remove block from

connector and wires

norman
norman