product bulletin: 67d series pressure reducing · pdf filethereby conserving plant air. smart...

12
Bulletin D103152X012 August 2016 Bulletin 71.1:67D 67D Series Pressure Reducing Regulators • Optional Smart Bleed™ Construction • Optional Stainless Steel Construction • Compact and Light Weight • No Air Loss Figure 1. 67D Series Pressure Reducing Regulators TYPE 67DF OR 67DFR FILTERED REGULATOR P1182_1 TYPE 67D OR 67DR REGULATOR P1183_1 • Easy Maintenance • Optional Integral Filter • Optional Internal Relief Valve • Rugged Construction

Upload: ngominh

Post on 19-Mar-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

BulletinD103152X012

August 2016

Bulletin 71.1:67D

67D Series Pressure Reducing Regulators

  •  Optional Smart Bleed™ Construction

  •  Optional Stainless  Steel Construction

  •  Compact and Light Weight

  •  No Air Loss

Figure 1. 67D Series Pressure Reducing Regulators

TYPE 67DF OR 67DFR FILTERED REGULATOR

P1182_1

TYPE 67D OR 67DR REGULATOR

P1183_1

  •  Easy Maintenance

  •  Optional Integral Filter

  •  Optional Internal Relief Valve

  •  Rugged Construction

Page 2: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

2

Bulletin 71.1:67D

1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded.2. Silicone (VMQ) is not compatible with hydrocarbon gas.3. Product complies with the material requirements of NACE International MR0175 or MR0103. Environmental limits may apply.4. Do not use in high aromatic hydrocarbon service.

SpecificationsThe Specifications section gives some general specifications for the 67D Series regulator. A label on the spring case gives the control spring range for a given regulator as it comes from the factory.

Available ConfigurationsType 67D: Direct-operated regulator with aluminum body and without internal relief Type 67DR: Aluminum body with internal relief Type 67DS: Stainless steel body without internal relief Type 67DSR: Stainless steel body with internal relief Type 67DF: Aluminum body with filter and without internal relief Type 67DFR: Aluminum body with filter and internal relief Type 67DFS: Stainless steel body with filter and without internal relief Type 67DFSR: Stainless steel body with filter and internal reliefSee also Table 1

Body Size, Inlet and Outlet Connection Style 1/2 NPT

Construction Materials See Table 3

Maximum Inlet Pressure (Body Rating)(1)

All filtered models: 250 psig / 17.2 barAll unfiltered models: 400 psig / 27.6 bar

Outlet Pressure Ranges See Table 2

Maximum Emergency Outlet Pressure(1)  150 psi / 10.3 bar over outlet pressure setting up to a

maximum of 250 psi / 17.2 bar

Flow Capacities See Table 4 and Capacity Information section

Wide-Open Flow CoefficientsMain Valve: Cg: 45.24; Cv: 1.33; C1: 35.02; Internal Relief Valve: Cg: 1.45; Cv: 0.045; C1: 32.8

IEC Sizing Coefficients Xt: 0.75

Types 67DR, 67DSR, 67DFR and 67DFSR Internal Relief Performance Low capacity for minor seat leakage only, other overpressure protection must be provided if inlet pressure can exceed the maximum pressure rating of downstream equipment or exceeds maximum outlet pressure rating of the regulator.

Approximate WeightsTypes 67D and 67DR: 1.2 lb / 0.5 kgTypes 67DF and 67DFR: 2.0 lbs / 0.9 kgTypes 67DS and 67DSR: 2.8 lbs / 1.2 kgTypes 67DFS and 67DFSR: 4.6 lbs / 2.1 kg

Smart Bleed™ Check Valve Setpoint 6 psi / 0.41 bar differential

Pressure Registration Internal

Spring Case Vent Location Aligned with inlet standard, other positions optional

Drain Valve Location Aligned in the center of the dripwell

Temperature Capabilities(1)

With Nitrile (NBR) Standard Bolting: -20 to 180°F / -29 to 82°C Stainless Steel Bolting: -40 to 180°F / -40 to 82°C

With Fluorocarbon (FKM):  Polyethylene Filter(4) (standard): 0 to 180°F / -18 to 82°C Polyvinylidene (PVDF), Stainless Steel or Glass Filter (Optional): 0 to 300°F / -18 to 149°C

With Silicone (VMQ)(2) diaphragm, Low Temperature Nitrile (NBR) O-rings and Low Temperature  bolting: -60 to 180°F / -51 to 82°CWith Gauges: -40 to 180°F / -40 to 82°C With Automatic drain: 40 to 175°F / 4 to 79°C

Types 67DF, 67DFR, 67DFS and 67DFSR Filter Capabilities Micron Rating:  Polyethylene Filter(4) (standard): 5 microns Glass Fiber Filter (Optional): 5 microns PVDF Filter (Optional): 40 microns Stainless Steel Filter (Optional): 40 microns

Page 3: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

3

Bulletin 71.1:67D

Specifications (continued)

IntroductionThe 67D Series regulators are typically used to deliver constant reduced pressure of gaseous fluids to pilot-operated controllers and other pneumatic instrumentation. As shown in the Available Configurations table, an assortment of regulators is available to meet diverse flow requirements.

Features  •   Compact—The 67D Series regulators are

engineered for outstanding performance in a compact, lightweight package.

  •   Pilot Supply Regulator—Improves the accuracy of two-path control regulators by reducing inlet sensitivity caused by fluctuating inlet pressures.

  •    Pressure Loading Regulator—Provides accuracy and improved performance in dirty steam service by eliminating the need for a pilot regulator.

  •   Sour Gas Service Capability—NACE International MR0175 and MR0103 compliant construction available.

•   Optional Stainless Steel Construction—The Types 67DS, 67DSR, 67DFS and 67DFSR provide high resistance to corrosion, which is especially beneficial for offshore applications.

  •   Full Usable Capacity—Fisher™ regulators are laboratory tested. 100% of the published capacities can be used with confidence.

  •   Internal Relief—The Types 67DR, 67DSR, 67DFR and 67DFSR have an internal relief valve with a soft seat for reliable shutoff with no discernible leakage. These regulators are recommended for conserving plant air.

  •   Smart Bleed™—Opens to exhaust downstream pressure when inlet pressure drops below outlet pressure. Recommended for dead-end service.

•   Integral Filter—The Types 67DF, 67DFR, 67DFS and 67DFSR have an integral filter ensuring clean downstream air supply.

  •   Ease of Maintenance—No special tools are required to perform maintenance and all maintenance can be performed with the regulator in the line. Filter elements are easily replaced.

  •   Rugged Construction—The 67D Series regulators are engineered for longer service life with minimal maintenance requirements.

  •   Dual Second Outlets—Body side outlets for pressure gauge or other uses.

•   Corrosion Resistant Fasteners—Bolting and adjusting screw are double zinc-chromated for enhanced corrosion resistance. Optional stainless steel bolting and adjusting screw are also available.

OptionsAll Types

• Handwheel adjusting screw • NACE International MR0175 or MR0103(3) construction • Panel mount (includes spring case with 1/4 NPT vent,

handwheel and panel mounting nut) • Closing cap (available on spring case with

1/4 NPT vent) • Fluorocarbon (FKM) elastomers for high temperatures

and/or corrosive chemicals

• Silicone (VMQ) elastomers for cold temperatures • Fixed Bleed Restriction • Triple scale outlet pressure gauge (brass or

stainless steel) • Stainless steel stem and valve plug • Pipe plug in second outlet

Types 67DFR and 67DFSR only • Smart Bleed internal check valve

Types 67DF, 67DFR, 67DFS and 67DFSR • Stainless steel drain valve

Page 4: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

4

Bulletin 71.1:67D

MATERIALTyPe

67D and 67DR 67DF and 67DFR 67DS and 67DSR 67DFS and 67DFSR

BODY AND  SPRING CASE Aluminum (ASTM B85/Alloy 380) CF8M/CF3M Stainless steel

SPRING RETAINER Aluminum Zinc-plated steel 316L Stainless steel

UPPER SPRING SEAT Zinc-plated steel316 Stainless steel

DIAPhRAGM PLATE Chromate conversion coated Aluminum

CONTROL SPRING Plated steel or Inconel® (NACE) Inconel®

VALVE STEM  

Brass, Aluminum or Stainless steel 316L Stainless steel

VALVE PLUG

VALVE SPRING Stainless steel or Inconel® (NACE)

DIAPhRAGM AND O-RINGS Nitrile (NBR), Fluorocarbon (FKM), Low Temp Nitrile (NBR) or Silicone (VMQ)(1)

SOFT SEAT AND GASKETS Nitrile (NBR) or Fluorocarbon (FKM)

BOLTING AND ADjUSTING SCREW Zinc-plated steel or Stainless steel

hANDWhEEL Zinc-plated steel Zinc-plated steel or Stainless steel

FILTER RETAINER - - - - 316 Stainless steel - - - - 316 Stainless steel

FILTER ELEMENT - - - - Plastic, Glass fiber or Stainless steel - - - - Plastic, Glass fiber or

Stainless steel

DRAIN VALVE - - - - Brass or 18-8 Stainless steel - - - - 316 Stainless steel or

18-8 Stainless steel

DRIPWELL - - - - Aluminum (ASTM B85/Alloy 380) - - - - CF8M/CF3M Stainless steel

1. Silicone (VMQ) diaphragm is only available with internal relief (Types 67DR, 67DSR, 67DFR and 67DFSR).

Table 3. Construction Materials

Table 2. Outlet Pressure Ranges and Control Spring Data

TyPeOUTLET PRESSURE RANGE

CONTROL SPRING DATA

Part Number Material Color CodeWire Diameter Free Length

psig bar In. mm In. mm

67D, 67DR, 67DF and 67DFR

0 to 200 to 35 0 to 60 0 to 125

0 to 1.40 to 2.40 to 4.10 to 8.6

GE07809T012T14059T0012T14058T0012T14060T0012

Music Wire

Green stripeSilver

Blue stripeRed stripe

0.1350.1560.1700.207

3.433.964.325.26

1.431.431.431.43

36.236.236.236.2

0 to 35 0 to 60 0 to 125

0 to 2.40 to 4.10 to 8.6

T14113T0012T14114T0012T14115T0012

Inconel®Silver stripe

BlueRed

0.1560.1720.207

3.964.375.26

1.43 1.43 1.43

36.236.236.2

67DS, 67DSR, 67DFS and 67DFSR

0 to 200 to 35 0 to 60 0 to 1250 to 150

0 to 1.40 to 2.40 to 4.10 to 8.60 to 10.3

10C1729X012T14113T0012T14114T0012T14115T001210C1730X012

Inconel®

GreenSilver stripe

BlueRed

Black

0.1350.1560.1720.2070.250

3.433.964.375.266.35

1.501.43 1.43 1.431.77

38.136.236.236.244.9

TyPe

CONSTRUCTION FEATURE OPTIONAL FEATURE BODY MATERIAL

With Internal Relief With Filter

Smart BleedTM Internal Check Valve Airset

Drain Valve External Fixed Bleed Aluminum Stainless Steel

67D X67DR X X X67DS X

67DSR X X X67DF X X X

67DFR X X X X X X67DFS X X X

67DFSR X X X X X X

Table 1. Available Configurations

Inconel® is a mark owned by Special Metals Corporation.

Page 5: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

5

Bulletin 71.1:67D

Principle of Operation (Figure 2)Downstream pressure is registered internally on the lower side of the diaphragm. When the downstream pressure is at or above the set pressure, the valve plug is held against the orifice and there is no flow through the regulator. When demand increases, downstream pressure drops slightly allowing the spring to extend, moving the stem down and the valve plug away from the orifice. This allows flow through the regulator.

Internal Relief (Types 67DR, 67DSR, 67DFR and 67DFSR) If for some reason, outside of normal operating conditions, the downstream pressure exceeds the setpoint of the regulator, the force created by the downstream pressure will lift the diaphragm until the diaphragm is lifted off the relief seat. This allows flow through the token relief. The relief valve on the Type 67DR, 67DSR, 67DFR or 67DFSR is an elastomer plug that prevents leakage of air from the downstream to atmosphere during normal operation, thereby conserving plant air.

Smart Bleed AirsetIn some cases, it is desired to exhaust downstream pressure if inlet pressure is lost or drops below the setpoint of the regulator. For example, if the regulator is installed on equipment that at times has no flow demand but is expected to backflow on loss of inlet pressure. The Type 67DFR or 67DFSR can be ordered with the Smart Bleed option which includes an internal check valve for this application. During

Figure 2. 67D Series Operational Schematics

INLET PRESSUREOUTLET PRESSURE

ATMOSPhERIC PRESSURE

M1153_02/09 M1154_02/09

TYPE 67DR OR 67DSR TYPE 67DFR OR 67DFSR

TYPE 67D OR 67DS TYPE 67DF OR 67DFS

Type XXXX

MXX

XX

Month Year Type XXXX

INLET PRESSUREOUTLET PRESSUREATMOSPHERIC PRESSURE

INTERMEDIATE PRESSUREPILOT SUPPLY PRESSURE

LOADING PRESSURE

SMART BLEED™ OPTION FOR TYPE 67DFR OR 67DFSR

operation, if inlet pressure is lost or decreases below the setpoint of the regulator, the downstream pressure will back flow upstream through the regulator and check valve. This option eliminates the need for a fixed bleed downstream of the regulator, thereby conserving plant air.

Note

During normal operation the check valve’s metal to metal seat allows limited flow through the regulator from the inlet to outlet, even when there is no downstream demand. To prevent downstream pressure buildup, the Smart Bleed option is only avilable with the internal relief version of the 67 Series. 

InstallationThe 67D Series regulators may be installed in any position but vertical orientation is recommended for models with draining features. Spring case vents must be protected against the entrance of rain, snow, debris or any other foreign material that might plug the vent openings. The inlet connection is marked “In” and the main outlet connection is marked “Out”. If a pressure gauge is not installed in one of the two secondary outlet connections, plug the unused connections. See Figures 4 and 5 for dimensions.

Emerson Process Management Regulator Technologies, Inc. provides an instruction manual with every regulator shipped. Refer to this for complete installation, operation and maintenance instructions. Included is a complete listing of individual parts and recommended spare parts.

Page 6: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

6

Bulletin 71.1:67D

Note

The 67D Series regulators may be sized for 100% flow using capacities as shown in Table 4. It is not necessary to reduce published capacities.

To determine the equivalent capacities for other gases, multiply the table capacity by the following appropriate conversion factor: 1.29 for 0.6 specific gravity natural gas, 0.810 for propane, 0.707 for butane or 1.018 for nitrogen. For gases of other specific gravities, divide the table capacities by the square root of the appropriate specific gravity. To find wide-open flow capacities for relief sizing at any inlet pressure, perform one of the following procedures. Then, if necessary, convert using the factors provided above.

For critical pressure drops (absolute outlet pressure equal to or less than one-half of absolute inlet pressure), use the following formula:

Q = (P1)(Cg)

For pressure drops lower than critical (absolute outlet pressure greater than one-half of absolute inlet pressure), use the following formula:

Q CgP1SIN= 520GT

3417C1

) ) PP1

DEG

where,

Q = gas flow rate, SCFH P1 = absolute inlet pressure, psia (P1 gauge + 14.7) Cg = gas sizing coefficient G = specific gravity of the gas T = absolute temperature of gas at inlet, °Rankine C1 = flow coefficient (Cg ÷ Cv) P = pressure drop across the regulator, psi

Then, if capacity is desired in normal cubic meters per hour (at 0°C and 1.01325 bar), multiply SCFH by 0.0268.

NACE Universal ComplianceOptional materials are available for applications handling sour gases. These constructions comply with the recommendations of NACE International sour service standards.

The manufacturing processes and materials used by Regulator Technologies assure that all products specified for sour gas service comply with the chemical, physical and metallurgical requirements of NACE MR0175 and/or NACE MR0103. Customers have the responsibility to specify correct materials. Environmental limitations may apply and shall be determined by the user.

Overpressure ProtectionThe 67D Series regulators have maximum outlet pressure ratings that are lower than their maximum inlet pressure ratings. A pressure-relieving or pressure-limiting device is needed if inlet pressure can exceed the maximum outlet pressure rating.

Types 67DR, 67DSR, 67DFR and 67DFSR regulators have a low capacity internal relief valve for minor seat leakage only. Other overpressure protection must be provided if the maximum inlet pressure can exceed the maximum pressure rating of the downstream equipment or exceeds maximum outlet pressure rating of the Type 67DR, 67DSR, 67DFR or 67DFSR regulator.

Overpressuring any portion of a regulator or associated equipment may cause leakage, parts damage or personal injury due to bursting of pressure-containing parts or explosion of accumulated gas. Regulator operation within ratings does not preclude the possibility of damage from external sources or from debris in the pipeline. A regulator should be inspected for damage periodically and after any overpressure condition.

Refer to the Capacity Information section and the Wide-Open Flow Coefficients for Relief Valve Sizing in the Specifications section on page 3 to determine the required relief valve capacity.

Capacity InformationTable 4 shows the air regulating capacities of the 67D Series regulators at selected inlet pressures and outlet pressure settings. Flows are shown in SCFH (at 60°F and 14.7 psia) and in Nm3/h (at 0°C and 1.01325 bar) of air.

Figure 3. 67D Series Vent Positions

GE31784

POSITION 1 (ALIGNED WITh INLET) (STANDARD)

POSITION 3

POSITION 2POSITION 4

Page 7: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

7

Bulletin 71.1:67D

OUTLET PRESSURE RANGE, SPRING PART 

NUMBER AND  COLOR CODE

OUTLET PRESSURE

INLET PRESSURE

 CAPACITIES IN SCFh / Nm3/h OF AIR

Types 67D, 67DR, 67DS and 67DSR Types 67DF, 67DFR, 67DFS and 67DFSR

psig bar psig bar5% Droop 10% Droop 20% Droop 5% Droop 10% Droop 20% Droop

SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h

0 to 20 psig / 0 to 1.4 bar GE07809T012(Green Stripe) 10C1729X012

(Green)

5 0.34

255075100150200250

400(1)

1.73.45.26.910.313.817.227.6

3207401000750850240290370

8.619.826.820.122.86.47.89.9

5301100270036003200810460590

14.229.572.496.585.821.712.315.8

9502200320041006100630063002700

25.559.085.811016316916972.4

320400460590780940

1000- - - -

8.610.712.315.820.925.226.8- - - -

400540850

2800170017001800- - - -

10.714.522.875.045.645.648.2- - - -

600110026002900390022002200- - - -

16.129.569.777.710559.059.0- - - -

10 0.69

255075100150200250

400(1)

1.73.45.26.910.313.817.227.6

45011002600 390034001200850470

12.1 29.569.710491.132.2 22.8 12.6

7901900320044006600780080003400

21.250.985.811817720921491.1

11002700390051007400780080004700

29.572.4105137198209214126

390600870

1100220019002000- - - -

10.516.123.329.559.050.953.6- - - -

570750

21003300320023002400- - - -

15.320.156.388.485.861.664.3- - - -

830170031003900480049003300- - - -

22.245.683.110512913188.4- - - -

20 1.4

5075100150200250

400(1)

3.45.26.910.313.817.227.6

15002600450067009000

11,2005500

40.269.7121180241300147

21003500490072009400

11,2006100

56.393.8 131193252300163

2600380051007600

10,00011,2009100

69.7102137204268300244

87016003600400033002900- - - -

23.342.996.510788.477.7- - - -

150026004300660047005100- - - -

40.269.7115177126137- - - -

210034004600660069007100- - - -

56.391.1123177185190- - - -

0 to 35 psig / 1 to 2.4 barT14059T0012 (Silver)

T14113T0012 (Silver Stripe)

15 1.0

255075100150200250

400(1)

1.73.45.26.910.313.817.227.6

4808601200200050001000500820

12.923.032.253.613426.813.422.0

7601500270039005900760089006400

20.440.272.4104158204239172

10002200370048007200880092007400

26.859.099.2129193236247198

360720870

1100340026002700- - - -

9.719.323.329.591.169.772.4- - - -

520130021003700570041003300- - - -

14.034.856.399.215311088.4- - - -

800210035004400640059006000- - - -

21.456.393.8118172158161- - - -

20 1.4

255075100150200250

400(1)

1.73.45.26.910.313.817.227.6

37077011001800620029004900830

9.920.629.548.216677.713122.2

57012002600450070007500

11,0008300

15.332.269.7121188201295222

81019003800520075007800

11,0008300

21.750.9102139201209295222

420880

11001800390056004400- - - -

11.323.629.548.2104150118- - - -

570150024003800660087008800- - - -

15.340.264.3102177233236- - - -

94023003900 4800700087008800- - - -

25.261.6105129188233236- - - -

35 2.4

5075100150200250

400(1)

3.45.26.910.313.817.227.6

10002000290067009000

11,1007600

26.853.677.7180241297204

17003200450071009500

11,9009300

45.685.8121190255319249

22003700510076009900

12,50012,800

59.099.2137204265335343

84015002000630088006000- - - -

22.540.253.6169236161- - - -

13002500390068009000

10,000- - - -

34.867.0104182241268- - - -

20003300470070009000

10,000- - - -

53.688.4126188241268- - - -

1. Inlet pressures above 250 psig / 17.2 bar with a maximum of 400 psig / 27.6 bar are only available on unfiltered models (Types 67D, 67DR, 67DS and 67DSR).

Table 4. 67D Series Flow Capacities

- continued -

Page 8: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

8

Bulletin 71.1:67D

Table 4. 67D Series Flow Capacities (continued)

OUTLET PRESSURE RANGE, SPRING PART NUMBER AND COLOR 

CODE

OUTLET PRESSURE

INLET PRESSURE

 CAPACITIES IN SCFh / Nm3/h OF AIR

Types 67D, 67DR, 67DS and 67DSR Types 67DF, 67DFR, 67DFS and 67DFSR

psig bar psig bar5% Droop 10% Droop 20% Droop 5% Droop 10% Droop 20% Droop

SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h SCFh Nm3/h

0 to 60 psig / 0 to 4.1 bar

T14058T0012 (Blue Stripe)T14114T0012 (Blue)

35 2.4

5075100150200250

400(1)

3.45.26.910.313.817.227.6

8501400190066009200

11,2001100

22.837.550.917724730029.5

14002500410071009600

11,50011,900

37.567.0110190257308319

2100360051007600

10,20011,50011,900

53.696.5137204273308319

69010001600310072009500- - - -

18.526.842.983.1193255- - - -

110019002700560084009500- - - -

29.550.972.4150225255- - - -

180029004300660089009500- - - -

48.277.7115177239255- - - -

60 4.1

75100150200250

400(1)

5.26.910.313.817.227.6

1200 210043009200

11,9004000

32.256.3115247319107

2200360069009700

12,40018,000

59.096.5185260332482

300046007600

10,20012,80018,000

80.4123204273343482

9201500260043009500- - - -

24.740.269.7115255- - - -

1600250052008300

10,600- - - -

42.967.0139222284- - - -

2600400066008800

11,100- - - -

69.7107177236297- - - -

0 to 125 psig / 0 to 8.6 bar

T14060T0012 (Red Stripe)T14115T0012 (Red)

60 4.1

75100135150200250

400(1)

5.26.99.310.313.817.227.6

690100015001700 250056003500

18.526.840.245.667.015093.8

120019003000350060008100

17,900

32.250.980.493.8161217480

20003000 4600530077009300

17,900

53.680.4123142206249480

67010001300140018002400- - - -

18.026.834.837.548.264.3- - - -

110018002500280041006600- - - -

29.548.267.075.0110177- - - -

20002900430052007600

10,200- - - -

53.677.7115139204273

- - - -

80 5.5

100135150200250

400(1)

6.99.310.313.817.227.6

1000 16001900290042003700

26.842.950.977.711399.2

1700300037006000

10,20019,900

45.680.499.2161273533

2900460054007700

12,20010,400

77.7123145206327279

9601500170022002900- - - -

25.740.245.659.077.7- - - -

17002800310048007100- - - -

45.675.083.1129190- - - -

3000460053008000

10,600- - - -

80.4123142214284- - - -

125 8.6

135150200250

400(1)

9.310.3 13.817.227.6

15002100 380058006800

40.256.3102155182

2500320056007800

19,400

67.085.8150209520

3500430067009000

20,900

93.8115180241560

1600180029004100- - - -

42.948.277.7110- - - -

2700320052007800- - - -

72.485.8139209- - - -

440052008000

10,400- - - -

118139214279- - - -

0 to 150 psig / 0 to 10.3 bar(2)

10C1730X012 (Black)

110 7.6

150200250

400(1)

10.313.817.227.6

1900270034004200

50.972.491.1113

330048006200

11,300

88.4129166303

55008300

10,50019,100

147222281512

200026003400- - - -

53.669.791.1- - - -

340048006000- - - -

91.1129161- - - -

56008000

10,400- - - -

150214279- - - -

135 9.3

150200250

400(1)

10.313.8 17.227.6

1800300039006400

48.2 80.4105172

330054006700

13,300

88.4145180356

56008300

10,70019,300

150222287517

180028003700- - - -

48.275.099.2- - - -

320051006600- - - -

85.8137177- - - -

55008200

11,000- - - -

147220295- - - -

150 10.3200250

400(1)

13.817.227.6

2900 40006400

77.7107172

52007400

13,900

139198373

830011,00019,700

222295528

29004100- - - -

77.7110- - - -

52007300- - - -

139196- - - -

820011,000- - - -

220295- - - -

1. Inlet pressures above 250 psig / 17.2 bar with a maximum of 400 psig / 27.6 bar are only available on unfiltered models (Types 67D, 67DR, 67DS and 67DSR). 2. Available for Types 67DS, 67DSR, 67DFS and 67DFSR only.

Page 9: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

9

Bulletin 71.1:67D

Figure 4. Types 67D, 67DR, 67DS and 67DSR Dimensions

TyPe

DIMENSION

A B C D e F G

In. mm In. mm In. mm In. mm In. mm In. mm In. mm

67D and 67DR2.35 60

3.66 934.54 115 2.98 76 1.49 38 2.75 70 0.63 16

67DS and 67DSR 5.12 130

IN. /mm

STANDARD DIMENSIONS FOR GAUGE OPTION STANDARD DIMENSIONS

C

D

e

B  MAx

A

SIDE OUTLET1/4 NPT

OPTIONAL GAUGE

SIDE OUTLET1/4 NPT

OUTLET CONNECTION1/2 NPTINLET CONNECTION

1/2 NPT

GG01138

F

GVENT

B

A

C

D

e

SIDE OUTLET1/4 NPT

1.33 / 34 

OPTIONAL GAUGE

SIDE OUTLET1/4 NPT

VENT1/4 NPT

OUTLET CONNECTION1/2 NPT

INLET CONNECTION1/2 NPT

CLOSING CAP

F

G

GG01145

1.44 / 37

TYPE 67DS OR 67DSR

TYPE 67D OR 67DR

Table 5. Types 67D, 67DR, 67DS and 67DSR Dimensions

Page 10: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

10

Bulletin 71.1:67D

Figure 5. Types 67DF, 67DFR, 67DFS and 67DFSR Dimensions

TyPe

DIMENSION

A B C D e F G h I

In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm

67DF and 67DFR 5.93 151 3.66 934.54 115 2.98 76 1.49 38 2.88 73 0.63 16 0.69 18 2.25 57

67DFS and 67DFSR 6.27 159 5.12 130

SIDE OUTLET1/4 NPT

SIDE OUTLET1/4 NPT

VENT

B  MAx

A

D

C

e

OPTIONAL GAUGE

OUTLET CONNECTION1/2 NPT

MOUNTING hOLES FOR 5/16 / 7.9DIAMETER BOLTS

I

2.92 / 74

h

INLET CONNECTION1/2 NPT

F

G

IN. /mm

GG01139

C

D

e

B

A

SIDE OUTLET1/4 NPT

OPTIONALGAUGE

1.33 / 34

VENT1/4 NPT

SIDE OUTLET1/4 NPT

INLET CONNECTION1/2 NPT

OUTLET CONNECTION1/2 NPT

MOUNTING hOLES FOR 5/16 / 7.9DIAMETER BOLTS

h

I

CLOSING CAP

G

F

GG01135

STANDARD DIMENSIONS FOR GAUGE OPTION STANDARD DIMENSIONS

TYPE 67DF OR 67DFR

TYPE 67DFS OR 67DFSR

Table 6. Types 67DF, 67DFR, 67DFS and 67DFSR Dimensions

Page 11: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

11

Bulletin 71.1:67D

Ordering GuideType (Select One) 67D (aluminum without internal relief)*** 67DR (aluminum with internal relief)*** 67DS (stainless steel without

internal relief)*** 67DSR (stainless steel with internal relief)*** 67DF (aluminum with filter and without

internal relief)*** 67DFR (aluminum with filter and

internal relief)*** 67DFS (stainless steel with filter and without

internal relief)*** 67DFSR (stainless steel with filter and

internal relief)***Quantity (Specify)

Spring Case Style (Select One) Drilled hole vent (Types 67D, 67DR, 67DF and

67DFR standard)*** 1/4 NPT vent (Types 67DS, 67DSR, 67DFS and

67DFSR standard)*** Single hole panel mount***

Adjusting Screw  (Select One) Square head (Types 67D, 67DR, 67DF and

67DFR standard)*** Square head with closing cap (Types 67DS, 67DSR,

67DFS and 67DFSR standard)*** Handwheel***

Outlet Pressure Range (Select One) 0 to 20 psig / 0 to 1.4 bar*** 0 to 35 psig / 0 to 2.4 bar*** 0 to 60 psig / 0 to 4.1 bar*** 0 to 125 psig / 0 to 8.6 bar*** 0 to 150 psig / 0 to 10.3 bar (Types 67DS, 67DSR,

67DFS and 67DFSR only)***

Diaphragm, O-rings and Valve Seat Plug (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)** Silicone (VMQ) diaphragm, Low Temperature

Nitrile (NBR) O-rings and Nitrile (NBR) valve seat*

Filter Material (Select One) Polyethylene (5 microns) (standard)*** Glass (5 microns)*** Polyvinylidene (PVDF) (40 microns)*** Stainless steel (40 microns)***

Drain Valve (Select One) Brass (Types 67DF and 67DFR standard)*** Stainless steel (Types 67DFS and

67DFSR standard)*** Automatic Drain with Nitrile (NBR) elastomers*** Automatic Drain with Fluorocarbon (FKM) elastomers**

Spring Case Vent Location (Select One) Position 1 - Aligned with inlet (standard)*** Position 2 Position 3 Position 4

External Fixed Bleed for Type 67DR, 67DSR, 67DFR or 67DFSR (Optional) Yes**Smart Bleed™ Internal Check Valve Airset            (Optional - Types 67DFR and 67DFSR only) Yes**

Second Outlet (Select One) Open (Types 67D, 67DR, 67DF and

67DFR standard)*** Plugged with pipe plug (Types 67DS, 67DSR, 67DFS

and 67DFSR standard)*** Pressure Gauge (see below)

Triple Scale Pressure Gauge (Optional) Brass Gauge or Stainless Steel Gauge 0 to 30 psig / 0 to 0.2 MPa / 0 to 2.1 bar*** 0 to 60 psig / 0 to 0.4 MPa / 0 to 4.1 bar*** 0 to 160 psig / 0 to 1.1 MPa / 0 to 11.0 bar***

- continued -

Ordering InformationWhen ordering, complete the Ordering Guide on pages 11 and 12. Refer to the Specifications section on page 3. Review the description to the right of each specification and

the information in each referenced table or figure. Specify your choice whenever a selection is offered.

Page 12: Product Bulletin: 67D Series Pressure Reducing  · PDF filethereby conserving plant air. Smart Bleed Airset In some cases, it is desired to exhaust downstream pressure

Bulletin 71.1:67D

Regulators Quick Order Guide* * * Readily Available for Shipment

* * Allow Additional Time for Shipment

* Special Order, Constructed from Non-Stocked Parts. Consult Your local Sales Office for Availability.

Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction.

Specification WorksheetApplication (Please designate units):Specific UseLine SizeGas Type and Specific GravityGas TemperatureDoes the Application Require Overpressure Protection? Yes No If yes, which is preferred: Relief Valve Monitor Regulator Shut-off DeviceIs overpressure protection equipment selection assistance desired?Pressure (Please designate units):Maximum Inlet Pressure (P1max)Minimum Inlet Pressure (P1min)Downstream Pressure Setting(s) (P2)Maximum Flow (Qmax)Performance Required:Accuracy Requirements?Need for Extremely Fast Response?Other Requirements: 

Ordering Guide (continued)NACE International MR0175 Construction (Optional)(1)

Yes (not available with gauge)**

NACE International MR0103 Construction (Optional) Yes (not available with gauge)**

Replacement Parts Kit (Optional) Yes, send one replacement parts kit to match

this order.

1. Product complies with the material requirements of NACE International MR0175. Environmental limits may apply.

Facebook.com/EmersonProcessManagement

LinkedIn.com/company/emerson-process-management

Twitter.com/emersonprocess

[email protected]

Fisher.com

D103152X012 © 2009, 2016 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 08/16. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management.

The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.

Emerson Process Management Regulator Technologies

Americas McKinney, Texas 75070 USA T +1 800 558 5853 +1 972 548 3574

Europe Bologna 40013, Italy T +39 051 419 0611

Asia Pacific Singapore 128461, Singapore T +65 6770 8337

Middle East and Africa Dubai, United Arab Emirates T +971 4 811 8100