product data 257 model specifications 261 fastener ... · ks1000 lp/cr lo-pitch & curved roof...
TRANSCRIPT
KS
100
0 L
P/C
R
Lo-P
itch
& C
urve
d R
oof
Syst
em
Product Data 257
Model Specifications 261
Fastener Selection 271
Construction Details 273
• Panel Dimensions 273• Side Joint & Panel/
Cover Cap Lap 274
• End Lap 275• Ridge 276• Eaves 278• Valley Gutter 281• Verge 282• Mono Ridge 289• Valley Hip 290• Hip 291• Lean-to Roof 292• Expansion Joint 294• Barrel Vault Rooflight
Mounted Off Ridge 295
• Barrel Vault Rooflight Mounted Mid Slope 297
• GRP Integral Rooflights 298• Roof Ventilator
Mounted Off Ridge 300
• Insulated Flues & Curb 302• Curved Roof Panel 303• Components 304
255
Lo-Pitch & Curved
Insulated Roof System
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS1000 LP Roof Panel
Superior specification and construction for roof slopes of 1.5° or curved roofs
of 150m radius and above
“”
256
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Pro
duct
Dat
a
KS1000 LP/CR Roof SystemLo-Pitch & Curved
257
ApplicationThe KS1000 LP/CR Roof is a high specification system suitablefor building applications for new build and refurbishment.i) roof slopes 1.5° and above after deflection.ii) curved roofs 150 metre radius and above.
1000mm cover width
AB
Panel Length
Dimensions & Weight
Product Reference Application Description
KS1000 LP/CR Standard Lo-pitch & curved roof panel.
KS1000 LP-FM Lo-pitch roof panel with Factory Mutual (FM) approval for roof applications. For KS1000 CR contact Kingspan Technical Design Bureau
KS1000 LP/CR-LPCB Lo-pitch & curved roof panel with Loss Prevention Certification Board (LPCB) approval for roof applications.
Product Tolerance
Cut to Length -5mm +10mm
Liner Sheet Length -5mm +10mm
Cover Width -0mm +3mm
Thickness -2mm +2mm
End Square -3mm +3mm
Available LengthsPanel lengths 1.8 to 28 metres are supplied. Panels less than1.8m long can be supplied but do not have a cut back asstandard and are subject to extra charge. Panels less than 1.8mlong which require a cut back can be provided, but will becharged at full 1.8m price, plus cutting costs.
*These panel thicknesses comply with Part L2 (England & Wales) and Part J (Scotland)† Aluminium faced panels are not LPCB andFM certified.
A - Core Thickness (mm) 45 60 80* 100*
B - Overall Dimension (mm) 80 95 115 135
Weight kg/m2 0.5/0.4 steel 9.5 10.1 10.9 11.4
Weight kg/m2 0.63/0.4 steel 11.2 11.8 12.6 13.1
Weight kg/m2 0.7/0.5 alum.† 5.67 6.27 7.07 7.50
Panel End Cut BackPanels can be supplied with a cut back of 75mm or flush ends.Panels less than 1.8m long which require a cut back can beprovided, but will be charged at full 1.8m price, plus cutting cost.
End LapIt is recommended that panels are used in continuous lengthsfrom ridge to eaves with no end laps. However, where an end lapmust be used the flush end of the down slope panel has a factoryfitted end lap stitching plate.
Cover CapThe cover cap is made from 0.5mm thick steel coated to thesame specification as the weather sheet of the panels. The capsare supplied in lengths up to 12 metres. Panels less than 1.8mlong which require a cutback are subject to extra charge.
Ref. No. 260a/04 to LPS 1181
Insurer Approved System
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
258
KS1000 LP/CR Roof SystemLo-Pitch & Curved
Materials - SteelSubstrate• HPS200/Celestia: ZA255 Galvalloy hot-dip zinc-aluminium
alloy coated steel (= 95% Zn/=5% Al) to BS EN 10214 : 1995,Grade Fe E220G with a Z275 zinc coating.
• PVDF: Galvatite, hot-dipped zinc coated steel to BS EN 10147: 1992. Grade Fe E220G with a Z275 zinc coating.
• Standard external sheet thickness 0.5mm, standard internalsheet thickness 0.4mm. Other thicknesses can be supplied tospecial order.
Coatings - External Weather Sheet• HPS200 Plastisol: 200 micron thick high performance coating
applied to the weatherside of the panel. Designed to achievehigh levels of durability and colour stability, is highly resistant todamage in transit and on-site.
• PVDF: 27 micron thick stoved fluorocarbon coating which hasexcellent colour stability even at temperatures as high as120°C.
• Celestia: 120 micron thick Plastisol coating 16 metallic colours.• Silicone Polyester: An economical coating with medium term
life for worldwide use.• Reverse side of sheet coated with a light grey polyester coating.• The sheet is available in either plain or stucco embossed finish.
Coatings - Internal Liner Sheet• Lining Enamel: 15 micron thick coating developed for use for
the internal lining of insulated panels. Standard colour is “brightwhite” with an easily cleaned surface.
• HPS200 Plastisol: 200 micron thick coating used in areaswhere there is high internal humidity, or a corrosive environment.
• Stelvetite Food & Hygiene Safe: This is a 120 micron thickchemically inert polymer film bonded to steel suitable forcladding the interior of cold stores, food processing buildingsand other hygiene applications.
• Reverse side of sheet coated with a light grey polyester coating.• The sheet is available in either plain or stucco embossed finish.
Materials - AluminiumSubstrate• Aluminium substrate, Grades 3003/4/5 series.• Standard external sheet thickness 0.7mm, standard internal
sheet thickness 0.5mm.
Coatings - External Weather Sheet• PVDF: 25 micron thick stoved fluorocarbon coating which has
excellent colour stability even at temperatures as high as 120˚C.• ARS Abrasion Resistant: 28 micron thick polyester or
polyurethane resin reinforced with polyamide high durabilitycoating with exceptionally good handling characteristics.
• Silicone Polyester: An economical coating with medium termlife for worldwide use.
• Alternatively the weather sheet can be supplied in mill finish,stucco embossed.
Coatings - Internal Liner Sheet• Standard internal facing is white polyester coated, plain or
stucco embossed.
Insulation Core• Polyisocyanurate (PIR): with zero ozone depletion (Zero ODP).
Available in LPCB and FM insurer approvedcertified product range. For KS1000 CR/FM please contactKingspan Technical Design Bureau.
SealsFactory Applied Side Lap TapeAll side laps have a factory applied anti condensation tape.Additionally a specially developed side lap tape is factory appliedto panels for low-temperature chill stores at extra cost.
Factory Applied Side & End Lap ProtectionIf specifiers require additional under lap corrosion protection, thiscan be factory applied at extra cost.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Pro
duct
Dat
a
KS1000 LP/CR Roof SystemLo-Pitch & Curved
259
Quality & DurabilityKingspan Insulated Panels are manufactured from the highestquality materials, using state of the art production equipment torigorous quality control standards, complying with ISO 9001: 2000standard, ensuring long term reliability and service life.
Guarantees & WarrantiesKingspan will provide external coating and product warranties andguarantees on an individual project basis.
PackingStandard PackingKS1000 LP/CR panels are stacked weather sheet to weathersheet (to minimise pack height). The top, bottom, sides and endsare protected with foam and timber packing and the entire pack iswrapped in plastic.The number of panels in each pack depends on panel thicknessand length. The table below is shown as a guide. Typical pack height is 1100mm. Maximum pack weight is 1500kg.
Sea FreightFully timber crated packs are available on projects requiringdelivery by sea freight shipping, at additional cost. Alternatively,steel containers can be used. Special loading charges apply.
DeliveryAll deliveries (unless indicated otherwise) are by road transport toproject site. Off loading is the responsibility of the client.
Site Installation Procedure Site assembly instructions are available from theKingspan Technical Design Bureau.
BiologicalKingspan panels are normally immune to attack from mould, fungi,mildew and vermin. No urea formaldehyde is used in theconstruction, and the panels are not considered deleterious.
FireSteel and aluminium outer and inner facings have Class 1 surfacespread of flame to BS 476: Part 7: 1987, and are Class 0, asdefined by Building Regulations. The panel surfaces are ratedFAA/SAA to BS 476: Part 3: 1975. KS1000 LP/CR insurer approved
panels are available with FM and LPCB certification,with steel facings. For KS1000 CR/FM contact KingspanTechnical Design Bureau.
AcousticsKS1000 LP/CR panels comply with Building Regulations Part E fornon-domestic buildings. For residential, domestic, educationand healthcare building applications, BB93 and HTM 2045solutions, consult Kingspan Technical Design Bureau.
All KS1000 LP/CR panels have a single figure weighted soundreduction Rw = 25dB.
Building Regulations & StandardsKingspan insulated roof and wall systems conform to the followingBuilding Regulations and Standards (Non-domestic buildings):
i) Approved Document A: Structure (England & Wales)
ii) Approved Document B: Fire (England & Wales)
iii) Approved Document E: Resistance to the Passage of Sound (England & Wales)
iv) Approved Document Part L2: Conservation of Fuel & Power (England & Wales)
v) Building Standard Part D: Structural Fire Precautions (Scotland)
vi Building Standard Part H: Resistance to the Transmission of Sound (Scotland)
vii) Building Standard Part J: Conservation of Fuel & Power (Scotland)
viii) Building Standard Part L: Conservation of Fuel & Energy (Ireland)
PerformanceThermal Insulation
Panel Thickness (mm) U value W/m2K
45 0.41
60 0.31
80 0.25*
100 0.21*
U - Thermal transmittance W/m2K* U Value calculated in accordance with the method required by the Building
Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland)
Panel Core Thickness 45 60 80 100
No. panel/pack (max.) 12 10 9 6
Sound Reduction Index (SRI) Tested
Frequency Hz 125 250 500 1k 2k 4k
SRI dB 17.2 20.0 23.2 23.4 23.2 40.5
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
260
KS1000 LP/CR Roof SystemLo-Pitch & Curved
Unfactored Load/Span Table (use calculated design windload values unfactored)
SPAN Core Load Uniformly Distributed Loads (kN/m2)CONDITION Thickness Type Span L in Metres
(mm) 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0
SINGLE SPAN 45 Downwards 2.45 2.10 1.82 1.59 1.40 1.20 094 0.74
Suction 3.09 2.73 2.41 2.16 1.94 1.74 1.57 1.41
Outer Sheet 60 Downwards 3.07 2.70 2.38 2.11 1.87 1.67 1.49 1.23
0.5mm steel Suction 4.17 3.73 3.35 3.02 2.59 2.20 1.90 1.65
Inner Sheet 80 Downwards 3.86 3.45 3.08 2.76 2.48 2.23 2.01 1.82
0.4mm steel Suction 5.65 5.13 4.39 3.60 3.01 2.56 2.21 1.93
L 100 Downwards 4.51 4.06 3.66 3.30 2.99 2.70 2.45 2.23
Suction 7.18 5.97 4.80 3.95 3.31 2.82 2.43 2.12
DOUBLE SPAN 45 Downwards 2.43 2.10 1.80 1.53 1.32 1.15 1.01 0.89
Suction 1.82 1.57 1.37 1.22 1.10 1.00 0.92 0.85
Outer Sheet 60 Downwards 2.93 2.43 2.06 1.76 1.53 1.34 1.18 1.05
0.5mm steel Suction 1.94 1.68 1.48 1.33 1.20 1.10 1.01 0.94
Inner Sheet 80 Downwards 3.32 2.78 2.37 2.04 1.78 1.56 1.39 1.24
0.4mm steel Suction 2.08 1.81 1.61 1.44 1.31 1.20 1.11 1.03
L L 100 Downwards 3.70 3.10 2.65 2.29 2.00 1.76 1.57 1.40
Suction 2.16 1.89 1.69 1.52 1.39 1.28 1.18 1.10
Notes:1. Values have been calculated using the limit state method described in the
“European Recommendations for the Design of Sandwich Panels”(ECCS document No.115 2001), taking imposed loads, temperature andcreep into account.
2. For each value individual and combined load cases with appropriate loadfactors and temperatures have been considered. These are detailed under“Structural Performance” in the Building Design Section.
3. The Table is for medium and light coloured panels, as recommended byKingspan for roofs.
4. The following deflection limits have been used:
Downward loading L/200
Suction loading L/150
5. For intermediate values linear interpolation may be used.
6. The standard fastener pattern is shown in the construction details. When thepanels are valley fixed to 1.6mm thick cold rolled steel purlins at 2m centresthe allowable suction load is 1.8kN/m2. For other fastener and purlinarrangements the allowable suction load can be calculated using theprocedure shown in the design example under “Structural Performance”in the Building Design Section..
7. The allowable steelwork tolerance between bearing planes of adjacentpurlins is L/600, where L is the purlin spacing.
8. Load span tables for panel specifications not shown are available fromthe Kingspan Technical Design Bureau.
9. FM approved panels spans must be limited to a maximum of 1.8 metres insingle or double span conditions.
Structural
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS1
00
0 L
P/C
R R
oof
Mod
el S
peci
ficat
ions
261
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
263
KS1
00
0 L
P/C
R R
oof
Mod
el S
peci
ficat
ions
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74A/LPS-B
Construction ApplicationLo-Pitch of 4° or above and Curved 150m Radius or above – Roof – LPS 1181 Grade B
ApplicationThe following specification is for the KS1000 LP/CR /Zero ODP/LPCB Lo-Pitch and Curved Insulated Roof Panel used forbuildings with roof slopes of 4° or curved roofs of 150m radius andabove with internal humidity class environments 1-4 inclusive.
For internal humidity class environment 5 i.e. swimming poolscontact Kingspan Technical Design Bureau.
KS1000 LP/CR is Loss Prevention Certification Board LPCBcertified to LPS 1181 Grade B.
Materials & CoatingsExternal Weather SheetSubstrate to be 0.5mm thick steel S220GD+ZA eutectic Galvalloyhot-dip zinc coated steel to BS EN10214: 1992. External coatingto be HPS200 Plastisol, 200 microns thick.Colour – Standard SC
Reverse to have a light grey polyester coating.
Insulation CoreTo consist of 80mm thick, closed cell, with zero ozone depletion(Zero ODP) and LPCB certified polyisocyanurate (PIR) insulation.
The auto-adhesive properties of the core bond the external andinternal sheets together, and control the panel thickness achievedduring manufacture.
Internal Liner SheetSubstrate to be 0.4mm thick hot-dip zinc coated Steel toBS EN10147: 1992.
Internal coating to be Lining Enamel, 15 microns thick. Colour - White.
Reverse to have a light grey polyester coating.
Cover CapsTo be made from 0.5mm thick steel coated to the samespecification as the external weather sheet of the panels and usedin typical lengths up to 12000mm.
PerformanceThermal InsulationThe panel must have a thermal transmittance (U value) of0.25 W/m2K calculated using the method required by the BuildingRegulations Part L2 (England & Wales) and Building StandardsPart J (Scotland).
FireThe external and internal faces of the panel to be Class 0 inaccordance with the Building Regulations when tested to BS 476:Parts 6: 1989 and Part 7: 1987.
The panel must be rated SAA when tested to BS 476: Part 3: 1975.
The system has passed all the requirements of LPS 1181: Issue 3ceiling lining test.
AirtightnessOverall airtightness for complete envelope less than 10m3/hr/m2
at 50Pa .
Seals & FillersSide JointAll side joints have a factory applied anti-condensation tape.
End LapAll external end laps to be 75mm long, and weather sealed alongthe full width using a single unbroken run of Scapa Tape 18mmwide x 4mm thick U section butyl rubber sealant tape, Ref: 0311.
In addition a single unbroken run of non-curing mastic appliedacross the complete with of the panel.
End laps to be tail stitched with carbon steel stitching screws,complete with 14mm diameter bonded stainless steel washers. Tail stitching to be positioned 25mm upslope from end lap and fivenumber per panel. Fasteners to penetrate the factory applied endlap stitching plate positioned in the downslope panel at the flushend.
An additional 150mm length of gun applied non-curing mastic tobe applied over 4 way laps.
Profiled FillersWhere flashings are fixed across the profile of the insulated panel,EPDM closed cell foam fillers should be used to seal and close theprofile. Seal the top, bottom and sides of each profiled filler with non-setting gun-grade sealant, Scapa Tapes, Ref: 0100. The flashing and filler to be supported using an apex dam Ref: LP1.
JunctionsJunctions between the roof panel system and walls / penetrationsinsulated with PIR board insulation any gaps filled with Alfasbond FR fire rated gun applied canister urethane insulation.
Internal face of panel to be air sealed along the full length by anunbroken Scapa Tape 6mm diameter butyl rubber sealant tape.
FastenersPrimaryAll primary fasteners must be the high threaded type,manufactured from carbon steel and fitted with a 16mm diameterbonded stainless steel washer.
All fasteners to be located at the side profile of the panel.
To comply with the requirements of BS 6399: Part 2: 1997, it maybe necessary to provide additional fixings in areas of high localsuction.
SecondaryFlashings to be stitched at 450mm centres (maximum) withcarbon steel, stitching screws, complete with 14mm diameterbonded stainless steel washers with integral colour matchedheads.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
264
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74A/LPS-B
Construction ApplicationLo-Pitch of 4° or above and Curved 150m Radius or above – Roof – LPS 1181 Grade B
Construction DetailsFlashingsAll external flashings to be made from 0.63mm thick steel to thesame specification as the outer sheet of the panel. Colour –Standard. All flashings to be weather sealed at laps and along thefull length by an unbroken bead of Scapa Tape 20mm wide x3mm thick butyl rubber sealant tape, Ref: 0311. All internalflashings to be made from 0.4mm thick steel substrate, to thesame specification as the inner sheet. Colour - white.
All internal flashings to be air sealed at laps and along the fulllength by an unbroken bead of Scapa Tape 6mm diameter butylrubber sealant tape, Ref: 0311. End laps to be air sealed withVapourflex or gun-grade sealant.
Panel LengthsExact lengths to be determined by the cladding contractor fromthe steelwork drawing, but typically using minimum number ofpanels from ridge to eaves up to a maximum panel length of 28.5metres.
Construction RequirementsSteelwork ToleranceThe steel frame must be made and assembled to an accuracy ofL/600 between fixing planes of adjacent purlins, where L. is thepurlin spacing, and generally to BS 5950: Part 2: 1992.
InstallationAll fasteners, seals and fillers to be of correct specification andinstalled as indicated on the project construction drawings.Site cut panels must provide accurate, true lines with no distortion.
Panels to be cut with powered reciprocating type saw and allexposed site cut panels to be treated with a suitable edgeprotection lacquer. Cut openings for outlets, vents, flues etc. to bethe minimum size necessary.
Remove all swarf and any foreign matter immediately from theexternal surface of panels.
Fasteners to be checked and adjusted if necessary to ensure theyare weather tight and external panel facing is not distorted.
SafetyThe contractor is to determine and use a safe method of workingthroughout the installation and construction period, whichcomplies with HSE & CDM requirements.
NBS Format SpecificationH43 - Metal Composite Panel
Cladding/CoveringTo be read with Preliminaries/General conditions.
122A - Metal Composite Roof Cladding
• Drawing reference(s): _________• Supports: Cold rolled purlins
Bearing width: 50mmPitch: Min 4° or above (Finished roof slope after deflections).
• Manufacturer and reference: Kingspan roof cladding systemfor standard internal and external environments and LossPrevention Certification Board certified to LPS 1181 Grade B.
• Test results: LPS 1181, Issue 3, ceiling lining tests: Passed all requirements.
• Panels:Profile reference: KS1000 LP/CR/Zero ODP/LPCB - Lo-Pitch and Curved InsulatedRoof Panel.External facings:• Material: Galvalloy hot-dip ZA255 coated steel to
BS EN 1021, Grade S220GD+ZA.• Thickness: 0.5mm• Finish/Colour: Colorcoat HPS200 Plastisol with Scintilla
finish, standard colour.Internal facings:• Material: Hot-dip zinc coated steel to BS EN 10147.• Thickness: 0.4mm• Finish/Colour: Lining Enamel, colour White.Core insulation: Zero ODP and LPCB certified.Panel thickness: 115mm overall (80mm core)
• End laps: 75mm.• End lap sealant:
• Single line of 18mm x 4mm U shaped, Scapa Tapes,Ref: 0311, site applied at lap in external facings.
• Single line of non-setting gun-grade, Scapa Tapes, Ref: 0100, site applied at lap in external facings.
• Non-setting gun-grade, Scapa Tapes, Ref: 0100, siteapplied to corners of profile at end lap.
• Side lap sealant:• Two anti-condensation tapes, factory applied at butt joint
between panels.• Fasteners: As determined by Clause 220C.
Number and location:• Primary fasteners: As determined by Clause 197A, but with
each panel fixed to each support using not less than twofastenings, located through the side panels asrecommended by cladding manufacturer.
• Secondary fasteners: Stitch external end laps using fivefastenings per panel, located 25mm upslope from end lap,penetrating factory applied stitching plate on underside ofdown slope panel.
P
LU
S
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
265
KS1
00
0 L
P/C
R R
oof
Mod
el S
peci
ficat
ions
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74A/LPS-B
Construction ApplicationLo-Pitch of 4° or above and Curved 150m Radius or above – Roof – LPS 1181 Grade B
• Cover Caps:Material: As per external facings.Thickness: 0.5mmFinish/Colour: Colorcoat as per external facings, colourstandard.Sealant:• Single line of non-setting gun-grade, Scapa Tapes,
Ref: 0100, site applied at 4 way laps.• Factory applied sealant tape at junction with panels.
• Accessories: Profiled fillers as Clause 300A.• Apex dams and profiled fillers as per manufacturers
recommendations, where flashing cross the profile of thepanel. Apex dams as determined by Clause 310A.
• Thermal Transmittance (U Value) calculated using the methodrequired by the Building Regulations Part L2 (England & Wales)and Building Standards Part J (Scotland): 0.25 W/m2K
• Air leakage rate of 10m3/hr/m2 at 50 Pa.• Other requirements:• Internal face of panel to be air sealed along the full length by
an unbroken run of 6mm diameter Scapa Tapes, Ref: 0311.
197A - Attachment• Determine the number and location of cladding fasteners
recommended by the cladding manufacturer to resist windloads calculated in accordance with BS 6399:Part 2 StandardMethod and BS 5427: Part 1.
• Calculate wind loads on roof and wall cladding appropriate tolocation, exposure, roof height, building shape and size inaccordance with BS 6399: Part 2 Standard Method andBS 5427: Part 1.
Basic wind speed (Vb): ___ m/sAltitude factor (Sa): ___Direction factor (Sd): ___Seasonal factor (Ss): 1Probability factor (Sp): 1Terrain and building factor (Sb): ___External and internal size effect factors (Ca): 1External pressure coefficients (Cpe): As determined fromBS 6399: Part 2, Clauses 2.4 and 2.5.Internal pressure coefficients (Cpi): As determined fromBS 6399: Part 2, Clause 2.6.Dominant opening: _________
220C - Fasteners• Manufacturer:
SFS Intec Ltd, tel. 0113 208 5500Ejot Ecofast Ltd, tel. 0113 247 0880
• Primary fasteners:High threaded screws with bonded washers.Type(s), size(s) and drilling capacity: As re-commended byfastener manufacturer to suit type and thickness of supports,and thickness of cladding panels.
Screw material: Anti-corrosion coated carbon steel.Washer material: Grade 304 austenitic stainless steel.Washer size: 16mm diameter.Heads: Not coloured
• Secondary fasteners: Stitching screws with bonded washers.Screw/washer material: As primary fasteners.Washer size: 14mm diameter.
Heads: Integral colour matched heads.
275A - Continuity Thermal Insulation• Junctions between the roof panel system and walls/
penetrations insulated with PIR board insulation any gaps filledwith Alfasbond FR fire rated gun applied canister urethaneinsulation.
• Placement: Secure and continuous with cladding/coveringinsulation.
300A - Profiled Fillers• Drawing reference(s): _________• Manufacturer and reference: Hartington Conway 0825, type
to suit cladding profile.Material: EPDM foam.Colour: Black.
• Fixing: Seal the top, bottom and sides of each profiled fillerwith a non-setting gun-grade, Scapa Tapes, Ref: 0100.
• Locate where shown on drawings and wherever necessary toclose off corrugation cavities from the inside and outside of thebuilding. Ensure a tight fit and leave no gaps.
310A - Purpose Made Cold Formed Metal AccessoriesExternal
• Drawing reference(s): _________• Material/finish: As external face of cladding.
Thickness: 0.63mmColour: To match external face of cladding.Workmanship as section Z11.
• Fixing: Stitch to external face of panels at 400mm centres usingsecondary fasteners as specified for the cladding system.
• Sealing: Single line of 20mm x 3mm Scapa Tapes, Ref: 0311, site applied between flashing and panel.
311A - Purpose Made Cold Formed Metal Accessories - Internal
• Drawing reference(s): _________• Material/finish: As internal face of cladding.
Thickness: 0.4mmColour: White.Workmanship as section Z11.
• Fixing: Stitch to internal face of panels at 450mm centresusing stainless steel secondary fasteners as specified for thecladding system.
• Sealing: Single line of 6mm diameter Scapa Tapes, Ref: 0311butyl rubber, site applied between flashing and panel.
• End laps to be air sealed with Vapourflex or gun-grade sealant.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
266
Snap-on matching/contrasting cover cap
Factory applied anti-condensation tape
Concealed throughfastener
Detail 1 - Side Lap
Detail 3 - Fastener Locations
End lap tail stitching screws Panel fastener
Panel fastener
Position of tailstitching screws
Continuous bead ofgun-grade sealant
Factory applied end lapstitching plate
75mm
25mm
Detail 2 - End Lap
18mm x 4mm U sectionbutyl rubber end lap sealant
KS1000 LP/LPCBinsulated roof panel
Air seal - 8mm Ø butylrubber sealant
Purlin
Profiled filler set back 80 to100mm to prevent bird attack
Apex dam (Ref: LP1)
Bead of non-curinggun-grade sealant
Site applied Alfasbondfire rated (FR) canister insulation
Internal ridge flashing with150mm overlap sealed withVapourflex or gun-grade sealant
Ridge flashing with 150mm sealed butt straps
Cover cap
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74A/LPS-B
Construction ApplicationLo-Pitch of 4° or above and Curved 150m Radius or above – Roof – LPS 1181 Grade B
Detail 4 - Ridge Detail
Profiled filler sealed top andbottom with gun-grade sealant
2 No. runs ofnon-curinggun-gradesealant
Note: For KS1000 CR (Curved) Model Specification construction details contact Kingspan Technical Design Bureau.
Note: For curved end lap detailscontact Kingspan TechnicalDesign Bureau.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
267
KS1
00
0 L
P/C
R R
oof
Mod
el S
peci
ficat
ions
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74B/LPS-B
Construction ApplicationLo-Pitch of 4° or below and Curved 150m Radius or above – Roof – LPS 1181 Grade B
ApplicationThe following specification is for the KS1000 LP/CR /Zero ODP/LPCB Lo-Pitch and Curved Insulated Roof Panel used forbuildings with roof slopes of 1.5° or curved roofs of 150m radiusand above with internal humidity class environments 1-4 inclusive.
For internal humidity class environment 5 i.e. swimming poolscontact Kingspan Technical Design Bureau.
KS1000 LP/CR is Loss Prevention Certification Board (LPCB)certified to LPS 1181 Grade B.
Materials & CoatingsExternal Weather SheetSubstrate to be 0.5mm thick steel S220GD+ZA eutectic Galvalloyhot-dip zinc coated steel to BS EN10214: 1992. External coatingto be Corus UK Limited Colorcoat HPS200 Plastisol, 200 micronsthick.
Colour – Standard SC
Reverse to have a light grey polyester coating.
Insulation CoreTo consist of 80mm thick, closed cell, with zero ozone depletion(Zero ODP) and LPCB certified polyisocyanurate (PIR) insulation.
The auto-adhesive properties of the core bond the external andinternal sheets together, and control the panel thickness achievedduring manufacture.
Internal Liner SheetSubstrate to be 0.4mm thick hot-dip zinc coated Steel toBS EN10147: 1992.
Internal coating to be Lining Enamel, 15 microns thick. Colour -White.
Reverse to have a light grey polyester coating.
Cover CapsTo be made from 0.5mm thick steel coated to the samespecification as the external weather sheet of the panels and usedin typical lengths up to 12000mm.
PerformanceThermal InsulationThe panel must have a thermal transmittance (U value) of0.25 W/m2K calculated using the method required by the BuildingRegulations Part L2 (England & Wales) and Building StandardsPart J (Scotland).
FireThe external and internal faces of the panel to be Class 0 inaccordance with the Building Regulations when tested to BS 476:Parts 6: 1989 and Part 7: 1987.
The panel must be rated SAA when tested to BS 476: Part 3: 1975.
The system has passed all the requirements of LPS 1181: Issue 3ceiling lining test.
AirtightnessOverall airtightness for complete envelope less than 10m3/hr/m2
at 50Pa .
Seals & FillersSide Joint
All side joints have a factory applied anti-condensation tape.
End LapAll external end laps to be 75mm long, and weather sealed alongthe full width using a single unbroken run of Scapa Tape 18mmwide x 4mm thick U section butyl rubber sealant tape, Ref: 0311.In addition a single unbroken run of non-curing mastic appliedacross the complete with of the panel.
End laps to be tail stitched with carbon steel stitching screws,complete with 14mm diameter bonded stainless steel washers.
Tail stitching to be positioned 25mm upslope from end lap and fivenumber per panel. Fasteners to penetrate the factory applied endlap stitching plate positioned in the downslope panel at the flushend.
An additional 150mm length of gun applied non-curing mastic tobe applied over 4 way laps.
Profiled FillersWhere flashings are fixed across the profile of the insulated panel,EPDM closed cell foam fillers should be used to seal and close theprofile. Seal the top, bottom and sides of each profiled filler withnon-setting gun-grade sealant, Scapa Tapes, Ref: 0100. Theflashing and filler to be supported using an apex dam, Ref: LP1.
JunctionsJunctions between the roof panel system and walls / penetrationsinsulated with PIR board insulation any gaps filled with AlfasbondFR fire rated gun applied canister urethane insulation.
Internal face of panel to be air sealed along the full length by anunbroken Scapa Tape 6mm diameter butyl rubber sealant tape.
FastenersPrimaryAll primary fasteners must be the high threaded type,manufactured from carbon steel and fitted with a 16mm diameterbonded stainless steel washer.
All fasteners to be located at the side profile of the panel.To comply with the requirements of BS 6399: Part 2: 1997, it maybe necessary to provide additional fixings in areas of high localsuction.
SecondaryFlashings to be stitched at 450mm centres (maximum) withcarbon steel, stitching screws, complete with 14mm diameterbonded stainless steel washers with integral colour matchedheads.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
268
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74B/LPS-B
Construction ApplicationLo-Pitch of 4° or below and Curved 150m Radius or above – Roof – LPS 1181 Grade B
Construction DetailsFlashingsAll external flashings to be made from 0.63mm thick steel to thesame specification as the outer sheet of the panel. Colour –Standard. All flashings to be weather sealed at laps and along thefull length by an unbroken bead of Scapa Tape 20mm wide x3mm thick butyl rubber sealant tape, Ref: 0311. All internalflashings to be made from 0.4mm thick steel substrate, to thesame specification as the inner sheet. Colour - white.
All internal flashings to be air sealed at laps and along the fulllength by an unbroken bead of Scapa Tape 6mm diameter butylrubber sealant tape, Ref: 0311. End laps to be air sealed withVapourflex or gun-grade sealant.
Ridge and EavesThe outer sheet of the panel must be turned up and turned downusing cladding manufacturers supplied tool at ridge and eavesrespectively.
Panel LengthsExact lengths to be determined by the cladding contractor fromthe steelwork drawing, but typically using minimum number ofpanels from ridge to eaves up to a maximum panel length of 28.5metres.
Construction RequirementsSteelwork ToleranceThe steel frame must be made and assembled to an accuracy ofL/600 between fixing planes of adjacent purlins, where L. is thepurlin spacing, and generally to BS 5950: Part 2: 1992.
InstallationAll fasteners, seals and fillers to be of correct specification andinstalled as indicated on the project construction drawings.Site cut panels must provide accurate, true lines with no distortion.
Panels to be cut with powered reciprocating type saw and allexposed site cut panels to be treated with a suitable edgeprotection lacquer. Cut openings for outlets, vents, flues etc. to bethe minimum size necessary.
Remove all swarf and any foreign matter immediately from theexternal surface of panels.
Fasteners to be checked and adjusted if necessary to ensure theyare weather tight and external panel facing is not distorted.
SafetyThe contractor is to determine and use a safe method of workingthroughout the installation and construction period, whichcomplies with HSE & CDM requirements.
NBS Format SpecificationH43 - Metal Composite Panel
Cladding/CoveringTo be read with Preliminaries/General conditions.
122A - Metal Composite Panel
• Drawing reference(s): _________• Supports: Cold rolled purlins
Bearing width: 50mmPitch: Min 1.5° or above (Finished roof slope after deflections).
• Manufacturer and reference: Kingspan roof cladding systemfor standard internal and external environments and LossPrevention Certification Board certified to LPS 1181 Grade B.
• Test results: LPS 1181, Issue 3, ceiling lining tests: Passed allrequirements.
• Panels:Profile reference: KS1000 LP/CR/Zero ODP/LPCB - Lo-Pitch and Curved InsulatedRoof Panel.External facings:• Material: Galvalloy hot-dip ZA255 coated steel to
BS EN 10212, Grade S220GD+ZA.• Thickness: 0.5mm• Finish/Colour: Colorcoat HPS200 Plastisol with Scintilla
finish, standard colour.Internal facings:• Material: Hot-dip zinc coated steel to BS EN 10147.• Thickness: 0.4mm• Finish/Colour: Lining Enamel, colour White.Core insulation: Zero ODP and LPCB certified.Panel thickness: 115mm overall (80mm core)
• End laps: 75mm.• End lap sealant:
• Single line of 18mm x 4mm U shaped, Scapa Tapes,Ref: 0311, site applied at lap in external facings.
• Side lap sealant:• Two anti-condensation tapes, factory applied at butt joint
between panels.• Fasteners: As determined by Clause 220C.
Number and location:• Primary fasteners: As determined by Clause 197A, but with
each panel fixed to each support using not less than twofastenings, located through the side panels asrecommended by cladding manufacturer.
• Secondary fasteners: Stitch external end laps using fivefastenings per panel, located 25mm upslope from end lap,penetrating factory applied stitching plate on underside ofdown slope panel.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
269
KS1
00
0 L
P/C
R R
oof
Mod
el S
peci
ficat
ions
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74B/LPS-B
Construction ApplicationLo-Pitch of 4° or below and Curved 150m Radius or above – Roof – LPS 1181 Grade B
• Cover Caps:Material: As per external facings.Thickness: 0.5mmFinish/Colour: Colorcoat as per external facings, colour standard.Sealant:• Single line of non-setting gun-grade, Scapa Tapes,
Ref: 0100, site applied at 4 way laps.• Non-setting gun-grade, Scapa Tapes, Ref: 0100, site
applied to corners of profile at end lap.• Factory applied sealant tape at junction with panels.
• Accessories: Profiled fillers as Clause 300A.• Apex dams and profiled fillers as per manufacturers
recommendations, where flashing cross the profile of thepanel. Apex dams as determined by Clause 310A.
• Thermal Transmittance (U Value) calculated using the methodrequired by the Building Regulations Part L2 (England & Wales)and Building Standards Part J (Scotland): 0.25 W/m2K
• Air leakage rate of 10m3/hr/m2 at 50 Pa.• Other requirements:
• Junctions between the roof panel system and walls /penetrations insulated with PIR board insulation any gapsfilled with Alfasbond FR fire rated gun applied canisterurethane insulation.
• Internal face of panel to be air sealed along the full length byan unbroken run of 6mm diameter Scapa Tapes, Ref: 0311.
• Turn up and turn down using cladding manufacturerssupplied tool at ridge and eaves respectively.
197A - Attachment• Determine the number and location of cladding fasteners
recommended by the cladding manufacturer to resist windloads calculated in accordance with BS 6399: Part 2 StandardMethod and BS 5427: Part 1.
• Calculate wind loads on roof and wall cladding appropriate tolocation, exposure, roof height, building shape and size inaccordance with BS 6399: Part 2 Standard Method andBS 5427: Part 1.
Basic wind speed (Vb): ___ m/sAltitude factor (Sa): ___Direction factor (Sd): ___Seasonal factor (Ss): 1Probability factor (Sp): 1Terrain and building factor (Sb): ___External and internal size effect factors (Ca): 1External pressure coefficients (Cpe): As determined fromBS 6399: Part 2, Clauses 2.4 and 2.5.Internal pressure coefficients (Cpi): As determined fromBS 6399: Part 2, Clause 2.6.Dominant opening: _________
220C - Fasteners• Manufacturer: One of the following:
SFS Intec Ltd, tel. 0113 208 5500Ejot Ecofast Ltd, tel. 0113 247 0880
• Primary fasteners:High threaded screws with bonded washers.Type(s), size(s) and drilling capacity: As re-commended byfastener manufacturer to suit type and thickness of supports,and thickness of cladding panels.Screw material: Anti-corrosion coated carbon steel.Washer material: Grade 304 austenitic stainless steel.Washer size: 16mm diameter.Heads: Not coloured
• Secondary fasteners: Stitching screws with bonded washers.Screw/washer material: As primary fasteners.Washer size: 14mm diameter.
Heads: Coloured plastic heads.
275A - Continuity Thermal Insulation• Junctions between the roof panel system and
walls/penetrations insulated with PIR board insulation any gapsfilled with Alfasbond FR fire rated gun applied canister urethaneinsulation.
• Placement: Secure and continuous with cladding/coveringinsulation.
300A - Profiled Fillers• Drawing reference(s): _________• Manufacturer and reference: Hartington Conway 0825, type
to suit cladding profile.Material: EPDM foam.Colour: Black.
• Fixing: Seal the top, bottom and sides of each profiled fillerwith a non-setting gun-grade, Scapa Tapes, Ref: 0100.
• Locate where shown on drawings and wherever necessary toclose off corrugation cavities from the inside and outside of thebuilding. Ensure a tight fit and leave no gaps.
310A - Purpose Made Cold Formed Metal AccessoriesExternal
• Drawing reference(s): _________• Material/finish: As external face of cladding.
Thickness: 0.63mmColour: To match external face of cladding.Workmanship as section Z11.
• Fixing: Stitch to external face of panels at 400mm centresusing secondary fasteners as specified for the claddingsystem.
• Sealing: Single line of 20mm x 3mm Scapa Tapes, Ref: 0311,site applied between flashing and panel.
311A - Purpose Made Cold Formed Metal Accessories - Internal
• Drawing reference(s): _________• Material/finish: As internal face of cladding.
Thickness: 0.4mmColour: White.Workmanship as section Z11.
• Fixing: Stitch to internal face of panels at 450mm centresusing stainless steel secondary fasteners as specified for thecladding system.
• Sealing: Single line of 6mm diameter Scapa Tapes, Ref: 0311butyl rubber, site applied between flashing and panel.
• End laps to be air sealed with Vapourflex or gun-grade sealant.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
270
Outer sheet turned up
Profiled filler sealed top andbottom with gun-grade sealant
KS1000 LP/LPCB insulated roof panel
Air seal - 8mm Ø butylrubber sealant
Purlin
Profiled filler set back 80 to100mm to prevent bird attack
Apex dam (Ref: LP1)
Cover cap
Bead of non-curinggun-grade sealant
Site applied Alfasbond fire rated (FR) canister insulation
Internal ridge flashing with150mm overlap sealed withVapourflex or gun-grade sealant
Ridge flashing with 150mm sealed butt straps
Snap-on matching/contrasting cover cap
Factory applied anti-condensation tape
Concealed throughfastener
Detail 1 - Side Lap
Detail 3 - Fastener Locations
Detail 4 - Ridge Detail
End lap tail stitching screws Panel fastener
Panel fastener
Position of tailstitching screws
Continuous bead ofgun-grade sealant
Factory applied end lapstitching plate
75mm
25mm
Detail 2 - End Lap
18mm x 4mm U sectionbutyl rubber end lap sealant
KS1000 LP/CR/Zero ODP/LPCB Lo-Pitch or Curved Roof System Ref No: 1/5.74B/LPS-B
Construction ApplicationLo-Pitch of 4° or below and Curved 150m Radius or above – Roof – LPS 1181 Grade B
2 No. runsof non-curing gun-gradesealant
Note: For KS1000 CR (Curved) Model Specification construction details contact Kingspan Technical Design Bureau.
Note: For curved end lap detailscontact Kingspan TechnicalDesign Bureau.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
271
KS
100
0 L
P/C
R R
oof
Fast
ener
Sel
ecti
on
SFS Intec Fastener Selector Guide
Product: Steel - KS1000 LP & CR Roof System- Side Seam Fixed (16mm diameter sealing washer)
Core Carbon Steel Fasteners Austenitic Stainless Steel Fasteners
Thickness (Building Classifications - Standard & Temperature Controlled) (Building Classifications - High Humidity, Low Temp, Hygiene)
(mm) Plain 8mm Hexagonal Head Plain Irius Head Plain 8mm Hexagonal Head
Cold Rolled 45 SDT5-A16-5,5x97 SDT5-L12-A16-5,5x97 SXC5-S16-5,5x1121.2-5mm 60 SDT5-A16-5,5x112 SDT5-L12-A16-5,5x112 SXC5-S16-5,5x130
80 SDT5-A16-5,5x137 SDT5-L12-A16-5,5x137 SXC5-S16-5,5x154
100 SDT5-A16-5,5x162 SXC5-S16-5,5x154
Hot Rolled 45 SDT14-A16-5,5x93 SDT14-L12-A16-5,5x93 SXC14-S16-5,5x1145-12mm 60 SDT14-A16-5,5x113 SDT14-L12-A16-5,5x113 SXC14-S16-5,5x114(14)
80 SDT14-A16-5,5x160 SDT14-L12-A16-5,5x160 SXC14-S16-5,5x134
100 SDT14-A16-5,5x160 SDT14-L12-A16-5,5x160 SXC12-S16-5,5x165
Timber 45 SDT5-A16-5,5x137 SDT5-L12-A16-5,5x137 SXCW-S16-6,5x135
60 SDT5-A16-5,5x162 SXCW-S16-6,5x155
80 SDT5-A16-5,5x162 SXCW-S16-6,5x185
100 SDT5-A16-5,5x226 SXCW-S16-6,5x185
End tail lap stitching fasteners
Sela Moulded Head Irius Powder Coated Head Sela Moulded Head Irius Powder Coated Head
SDP3-T19-5,5x38xcolour SD3-L12-T19-5,5x38xcolour Not available SX3/15-L12-S19-5,5x38xcolour
Stitching fasteners for fixing of flashings
Sela Moulded Head Irius Powder Coated Head Sela Moulded Head Irius Powder Coated Head
SLP2-T-A14-4,8x20xcolour SDL3-L12-T15-5,5x25xcolour SLP2-S-A14-4,8x20xcolour SXL2-L12-S14-5,5x22xcolour
PurlinType & Thickness
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
273
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Panel Dimensions
53˚
56°
35 AB
Exte
rnal
wea
ther
she
et
Inte
rnal
line
r she
et
Not
e:Ab
ove
dim
ensi
ons
are
theo
retic
al, a
ctua
l di
men
sion
s w
ill
vary
due
to m
anuf
actu
ring
tole
ranc
es.
Exac
tly p
reci
se d
imen
sion
s m
ust a
lway
s
be m
easu
red
from
act
ual s
ampl
es
All d
imen
sion
s in
milli
met
res.
Anti
cond
ensa
tion
tape
(Fac
tory
app
lied)
Fast
ener
loca
tion
Anti
cond
ensa
tion
tape
(Fac
tory
app
lied)
Fast
ener
loca
tion
36.5
52.4
751
.26
52.4
762
.33
52.4
662
.33
52.4
652
.46
62.3
352
.46
62.3
352
.47
51.2
652
.47
36.5
51.2
6
37.2
916
.7
303m
m R
adiu
s7
33.3
33.3
33.3
6.5
3.5
1000
cov
er w
idth
3
1.5
33.3
33.3
33.3
1.0
Insu
latio
n co
re
Avai
labl
e P
anel
Thi
ckne
sses
Insu
latio
n O
vera
ll P
anel
C
ore
(A)
Thic
knes
s (B
)
4580
6095
8011
5
100
135
Not
e:Tw
o se
ts o
f con
stru
ctio
n de
tails
hav
e be
en p
rodu
ced
to g
ive
the
build
ing
desi
gner
flex
ibili
ty w
ithin
the
Par
t L2
calc
ulat
ion
for t
he to
tal b
uild
ing
heat
loss
Alp
ha (a
). Th
ede
cisi
on o
n th
e ch
oice
of
or
deta
ils is
take
n by
the
build
ing
desi
gner
and
is d
eter
min
edfro
m th
e P
art L
2 to
tal h
eat l
oss
met
hodo
logy
. A m
ixtu
re o
fbo
th s
tand
ard
and
enha
nced
det
ails
may
be
requ
ired
for
som
e pr
ojec
ts.
STA
ND
AR
DE
NH
AN
CE
D
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
274
Side Joint Detail
Panel/Cover Cap Lap Details
Snap-on matching/contrasting cover-cap
Concealed throughfastener
1000mm 1000mm
Internal liner sheet
Upper cover cap
Lower cover cap
Non-curing mastic
46mm
Factory applied seal
Factory formed joggle joint
End lap of cover cappointed with non-curingmastic on completion
External weather sheet
Line of end lap
2 runs of non-curing gun-grade mastic to side joint
73mm
22mm
4mm Ø vapour seal whenrequired (site applied)
Continuous run of non-curing mastic
18mm x 4mm U section butyl rubber sealant
75mm
Factory formed joint
Anti condensation tapes(Factory applied)
Continuous run of 125mm non-curing mastic appliedover notched top panels ensuring joint is fully sealed
Remove factoryapplied seal on site
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
275
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
End Lap Detail
Cover cap
75mm factory
formed joint
Minimum of 300mm between panel
end lap and cover cap end lap
75mm End lap
15mm
10mmMax
25mm
10mmMin
30mmMin
Snap-on cover cap over lower cover cap
End of cover cap pointed with mastic
Factory fitted endlap stitching plate
Continuous bead of non-curing gun-grade sealant
End lap fixing/stitching screw
End Lap Stitching Screw Locations
18mm x 4mm U sectionbutyl rubber sealant
Continuous bead ofgun-grade sealant
2 runs of non-curing gun-grade masticto side joint
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Ridge Detail
276
Outer sheet turned up with roof slopes below 4˚
KS1000 LP/LPCBinsulated roof panel
Air seal - 8mm Øbutyl rubber sealant
Purlin
Profiled filler set back 80 to100mm to prevent bird attack
Apex dam (Ref: LP1)
Cover cap
Ridge Detail
Bead of non-curinggun-grade sealant
Mineral fibre insulation
Site applied Alfasbond fire rated(FR) canister insulation
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.004 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Ridge flashing with 150mmsealed butt straps
STANDARD
STANDARD ENHANCED
ENHANCED
2 No. runs of non curing gun-grade sealant
Profiled filler sealedtop and bottom withgun-grade sealant
Internal ridge flashingwith 150mm overlapsealed with Vapourflex orgun-grade sealant
Air seal - 8mm Øbutyl rubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
277
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Ridge Detail
Bead of non-curing gun-grade sealant
External ridge flashing
Cover cap
Outer sheet turned up
Apex dam (Ref: LP1)
Gun applied urethane foam
Internal ridge flashing
1000mm module
1000mm module
Verge trimapex piece
Ridge purlin
Ridge flashing
Bead of non-curinggun-grade sealant
Apex dam (Ref: LP1)
Special profiled fillersealed top and bottom
Cover cap
Special profiled fillersealed top and bottom
2 runs of non-curinggun-grade sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Eaves Detail
278
Parapet Detail -Boundary Wall Gutter
35m
m
min
60mm
Parapet flashing with 150mm sealed butt straps
Air seal - 6mm Ø butyl rubber sealant
Parapet rail with air seal - Vapourflex tape to rail joints
Mineral fibre insulation site applied
Butyl rubber sealant
Air seal - 6mm Ø bead of gun-grade sealant
Profiled filler sealed top and bottom with gun-grade sealant
Air seal - 6mm Ø butyl rubber sealant
Purlin
Gutter outlet
Eaves beam gutter support
KS1000 LP/LPCB insulated roof panelKS1000 MR/
LPCB wall panelhorizontally laid
4mm Ø butylrubber sealant
Sheeting rail
Gun-grade seal atpanel joints inlinewith 8mm butyl
Top sheet turneddown on site with roofpitches below 4˚
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.48 Ψ = 1.63 W/mK 0.35 W/m2K gutter fmin = 0.48 Ψ = 1.72 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
Dire
ctio
n of
lay
Air seal - 8mm Ø butyl rubber sealant2mm external non-thermallybroken factory made gutterwith PIR insulation to 0.25 or 0.35 W/m2K U-value
STANDARD
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.90 Ψ = 0.13 W/mK 0.35 W/m2K gutter fmin = 0.90 Ψ = 0.21 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
ENHANCED
ENHANCED
Site applied Alfasbond firerated (FR) canister insulation
Factory made thermally broken membrane lined gutterwith PIR board insulation to 0.25 or 0.35 W/m2K U-value
ENHANCED
Site applied Alfasbond fire rated(FR) canister insulation
Site applied PIR board insulation
KS1000 RW/LPCB wall panelvertically laid
Mineral fibreinsulation siteapplied
75mm
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Eaves Detail
279
Parapet Detail
Air seal - 8mm Ø butylrubber sealant
Flashing (lead or similar)by building contractor
Top sheet turned downon site with roof pitchesbelow 4°
75mm
Factory made thermallybroken membrane linedgutter with PIR boardinsulation to 0.25 or 0.35 W/m2K U-value
KS1000 LP/LPCBinsulated roof panel
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.89 Ψ = 0.12 W/mK 0.35 W/m2K gutter fmin = 0.89 Ψ = 0.19 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.86 Ψ = 0.18 W/mK 0.35 W/m2K gutter fmin = 0.86 Ψ = 0.24 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
Gun-grade seal at panel joints
inline with 8mm butyl
Eaves beamgutter support
Parapet Detail
KS1000 LP/LPCB insulated roof panel
Profiled filler sealed top andbottom with gun-grade sealant
Gun-grade seal at panel joints inline with 8mm butyl
Air seal - 8mm Ø butyl rubber sealant
PIR board insulation with site applied Alfasbond firerated (FR) canister insulation to fill any gaps ifrequired to maintain continuity of insulation
6mm Ø butylrubber sealant Air seal - 6mm Ø
butyl rubber sealant
Top sheet turned downon site with roof pitchesbelow 4°
75mm
Factory made thermallybroken membrane linedgutter with PIR boardinsulation to 0.25 or0.35 W/m2K U-value
Eaves beamgutter support
Parapet flashing with150mm sealed buttstraps
AWP filler with gun-gradesealant
KS1000 MR/LPCBvertically laid
Air seal - continuous beadof gun-grade sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
280
Eaves Detail
Building Regulations Part L2 Thermal Data
fmin = 0.95 Ψ = 0.31 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Internal liner sheet
Concealed through fastener
Gutter support 0.63mm thick HPS200 coating both sides
Cover cap
50mm
30mm
40m
m
STANDARD
STANDARD
Building Regulations Part L2 Thermal Data
fmin = 0.95 Ψ = 0.13 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
ENHANCED
ENHANCED
Eaves beam
20mm
35mm
20mm
Gutter support 0.63mm thick doubled sided plastisol coated
Top sheet turned down on site with roof pitches below 40
9mm x 3mm butyl rubber sealant
Stitching screw fixingsfor gutter brackets
75mm Approx
200mm fixing centres 200mm fixing centres
Eaves Detail - External Gutter
Gun -grade sealant at paneljoints inline with 8mm butyl
Air seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø butyl rubber sealant
*
* Air seal - Vapourflex sealant is tobe applied over any breaks insupporting secondary steelwork togive a continuous bearing face.
Mineral fibre insulation site applied
Site applied Alfasbond fire rated (FR) canister insulation
Stitching screw fixingsfor gutter brackets
KS1000 MR/ LPCB wall panel horizontally laid
Double sidedPlastisol “Highline”type gutter
KS1000 LP/LPCBinsulated roof panel
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
281
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Valley Gutter Detail
75mmCover cap
Purlin
Gutter outlet offset tomiss stanchion head tie
Factory made thermally broken membranelined gutter with PIR board insulation to 0.25or 0.35 W/m2K U-value
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.96 Ψ = 0.13 W/mK0.35 W/m2K gutter fmin = 0.96 Ψ = 0.25 W/mK0.35 sole width 600mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
Valley Gutter Detail
Valley Gutter Detail
ENHANCED
ENHANCED
75mmCover cap
Purlin
Air seal - 8mm Øbutyl rubber sealant
Stanchion headtie if necessaryas steelworkdesign
Air seal - 8mm Ø butylrubber sealant
2mm external non-thermallybroken factory made gutterwith PIR insulation to 0.25 or0.35 W/m2K U-value
Building Regulations Part L2 Thermal Data
0.25 W/m2K gutter fmin = 0.74 Ψ = 1.07 W/mK0.35 W/m2K gutter fmin = 0.71 Ψ = 1.38 W/mK0.35 sole width 600mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.
STANDARD
Gutter outlet offset to missstanchion head tie
Top sheet turned down on sitewith roof pitches below 4˚
Gun-grade seal at panel jointsinline with 8mm butyl
Gun-grade seal at panel joints inlinewith 8mm butyl
Top sheet turned down on sitewith roof pitches below 4˚
Air seal - 8mmØ butyl rubbersealant
Stanchion headtie if necessaryas steelworkdesign
Air seal - 8mm Øbutyl rubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
282
Verge Detail
Verge Detail - Wall Cladding (Start of roof sheeting)
Verge Detail - Wall Cladding (Start of roof sheeting)
Direction of lay
Verge flashing with 150mm sealed butt straps
20mm x 3mm butyl rubber sealant
Air seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø bead of gun-grade sealant
Gable rafter
4mm Ø butyl rubber sealant
Mineral fibre insulation site applied
Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints
KS1000 LP/LPCB insulated roof panel
KS1000 MR/LPCB insulatedwall panel horizontally laidBuilding Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.18 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Purlin
STANDARD
STANDARD
Direction of lay
Verge flashing with 150mm sealed butt straps
20mm x 3mm butyl rubber sealant
Purlin
Air seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø bead of gun-grade sealant
Gable rafter
4mm Ø butyl rubber sealant
PIR board insulation with site applied Alfasbond fire rated (FR) canisterinsulation to fill any gaps if required to maintain continuity of insulation
Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at jointsKS1000 LP/LPCB insulated roof panel
KS1000 MR/LPCB insulatedwall panel horizontally laid
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
ENHANCED
ENHANCED
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
283
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Verge Detail
Verge Detail - Wall Cladding (End of roof sheeting)
Verge Detail - Wall Cladding (End of roof sheeting)
Direction of lay
Verge flashing with 150mm sealed butt straps
20mm x 3mm butyl rubber sealant
PurlinAir seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø bead of gun-grade sealant
Gable rafter
4mm Ø butyl rubber sealant
Mineral fibre insulation site applied
Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints
KS1000 LP/LPCB insulated roof panel
KS1000 MR/LPCB insulated wallpanel horizontally laid
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.18 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
STANDARD
STANDARD
ENHANCED
ENHANCED
Direction of lay
Verge flashing with 150mm sealed butt straps
20mm x 3mm butyl rubber sealant
Purlin
Air seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø bead of gun-grade sealant
Gable rafter
4mm Ø butyl rubber sealant
PIR board insulation with site applied Alfasbond fire rated (FR) canisterinsulation to fill any gaps if required to maintain continuity of insulation
Cleader angle by steel sub-contractor withair seal Vapourflex sealant applied at jointsKS1000 LP/LPCB insulated roof panel
KS1000 MR/LPCB insulatedwall panel horizontally laid4mm Ø butyl rubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Verge Detail
284
Profiled filler sealed top and bottomwith gun-grade sealant
Parapet rail air seal - Vapourflex to rail joints
Butyl rubber sealant
Air seal - 8mm Ø butylrubber sealant
KS1000 LP/LPCBinsulated roof panel
20mm x 3mm butylrubber sealant
Verge flashing sealed 150mm laps
Air seal - 6mm Ø butyl rubber sealant
Mineral fibre insulation
Apply edge protectionlacquer to site cut edge
Mineral fibre insulation
Parapet flashing with150mm sealed buttstraps
4mm Ø butyl rubbersealant
KS1000 MR/LPCBhorizontally laid
Purlin
internal ridge flashing with 150mmoverlap sealed with air seal -Vapourflex or gun-grade sealant
Air seal - 6mm Ø butyl rubber sealant
Parapet Verge Detail
Building Regulations Part L2 Thermal Data
fmin = 0.37 Ψ = 1.14 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
STANDARD
Building Regulations Part L2 Thermal Data
fmin = 0.44 Ψ = 0.89 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
ENHANCED
ENHANCED
Direction of lay
PIR board insulation with site appliedAlfasbond fire rated (FR) canisterinsulation to fill any gaps if requiredto maintain continuity of insulation
PIR board insulation with site appliedAlfasbond fire rated (FR) canisterinsulation to fill any gaps if requiredto maintain continuity of insulation
STANDARD
ENHANCED
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Verge Detail
285
Verge to Brick Detail - Start
Continuous bead of gun-grade sealant
KS1000 LP/LPCBinsulated roof panel
20mm x 3mm butylrubber sealant
Verge flashing sealed 150mm laps
Air seal - 8mm Øbutyl rubber sealant
Internal ridge flashing with 150mmoverlap sealed with air seal -
Vapourflex or gun-grade sealant
PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gaps
if required to maintain continuity of insulation
Direction of lay
Air seal - continuous bead of gun-grade sealant
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Verge to Brick Detail - Finish
KS1000 LP/LPCB insulated roof panel
20mm x 3mm butyl rubber sealant
Verge flashing sealed 150mm laps
Air seal - 8mm Ø butyl rubber sealant
Internal ridge flashing with 150mmoverlap sealed with air seal -Vapourflex or gun-grade sealant
Direction of lay
Air seal - continuous bead of gun-grade sealant
Building Regulations Part L2 Thermal Data
fmin = 0.95 Ψ = 0.02 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gapsif required to maintain continuity of insulation
Continuous bead of gun-grade sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Verge Detail
286
Verge to Brick Detail
Flashing (lead or similar) tucked into brickcourse and pointed by building
KS1000 LP/LPCB insulated roof panel
20mm x 3mm butyl rubber sealant
Verge flashing sealed 150mm laps
Air seal - 8mm Ø butyl rubber sealant
PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gaps if
required to maintain continuity of insulation
Direction of lay
Air seal - continuous bead of gun-grade sealant75m
m m
in.
cove
r
150m
m m
in.
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Internal ridge flashing with150mm overlap sealed with airseal - Vapourflex or gun-grade
sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Verge Detail
287
Verge to Brick Detail
Flashing (lead or similar) tucked into brickcourse and pointed by building
KS1000 LP/LPCB insulated roof panel
20mm x 3mm butyl rubber sealant
Verge flashing sealed 150mm laps
Air seal - 8mm Ø butyl rubber sealant
Internal ridge flashing with 150mmoverlap sealed with air seal -Vapourflex or gun-grade sealant
PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gapsif required to maintain continuity of insulation
Direction of lay
Air seal - continuous bead of gun-grade sealant 75m
m m
in.
cove
r
150m
m m
in.
Building Regulations Part L2 Thermal Data
fmin = 0.95 Ψ = 0.02 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Verge Detail
288
Overhanging Gable
Direction of lay
Verge flashing
20mm x 3mm butyl rubber sealant
9mm x 3mm butyl rubber sealantSite applied Alfasbond fire rated (FR) canister insulation tofill any gaps if required to maintain continuity of insulation
Air seal - 8mm Ø butyl rubber sealant
Air seal - 6mm Ø beadof gun-grade sealant
Cleader angle
Purlin
FlashingSilicone sealant
Vertical sheeting rail
Flashing to suit linermaterial site cut around
purlins as necessary
Single skin soffit sheet
Cleader angle
Profiled filler sealed top and bottom
STANDARD
Verge flashing
20mm x 3mm butyl rubber sealant
Verge zed support with 150mm sealed overlaps
20mm x 3mm butyl rubber sealant
Air seal 8mm Ø butyl rubber sealant
Purlin
Cleader angle by steel sub-contractor withair seal Vapourflex sealant applied at joints
Air seal - 6mm Ø bead of gun-grade sealant
Internal vergeflashing with150mm overlapsealed with air seal -Vapourflex orgun-gradesealant
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
ENHANCED
Building Regulations Part L2 Thermal DataPlease consult Kingspan Technical Design Bureaufor thermal data.
Site appliedAlfasbond firerated (FR) canisterinsulation to fill anygaps if required tomaintain continuityof insulation
KS1000 MR/LPCBhorizontally laid
4mm Ø butylrubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Mono Ridge Detail
289
Mono Ridge Detail
Mono Ridge Detail
Cover cap
Profiled filler set back 80 to 100mmto prevent bird attack
Air seal - 8mm Ø butyl rubber sealant
Profiled filler sealed top and bottomwith gun-grade sealant
2 No. runs of non curinggun-grade sealant
KS1000 RW/LPCB vertically laid
Air seal - 6mm Ø butyl rubber sealant
Internal ridge flashing with 150mm overlapsealed with air seal - Vapourflex orgun-grade sealant
Profiled filler sealed top andbottom with gun-grade sealant
Mono ridge flashing with 150mmsealed butt straps
PIR board insulation with siteapplied Alfasbond fire rated (FR)canister insulation to fill anygaps if required to maintaincontinuity of insulation
Top sheet turned up withroof slopes below 4°
Apex dam (Ref: LP1)
Bead of non curing gun-grade sealant
Maximum cantilever (generally 300mm)
KS1000 LP/LPCB insulatedroof panel
Cover cap
Profiled filler set back 80 to 100mmto prevent bird attack
Air seal - 8mm Ø butylrubber sealant
Profiled filler sealed top andbottom with gun-grade sealant
2 No. runs of non curinggun-grade sealant
Air seal - continuous bead ofgun-grade sealant
Continuous bead of gun-grade sealant
Internal ridge flashing with 150mmoverlap sealed with air seal -Vapourflex or gun-grade sealant
KS1000 LP/LPCB insulatedroof panel
Building Regulations Part L2 Thermal Data
fmin = 0.95 Ψ = 0.01 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.04 W/mKThe appropriate Ψ value for the brickwork, blocks or concrete must beadded to the above Ψ value to obtain the total heat loss through thisjunction detail.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Maximum cantilever (Generally 300mm)
Mono ridge flashing with150mm sealed butt straps
Top sheet turned up withroof slopes below 4º
Apex dam (Ref: LP1)
Bead of non curing gun-grade sealant
PIR board insulation with siteapplied Alfasbond fire rated(FR) canister applied insulationto fill any gaps if required tomaintain continuity of insulation
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
Valley Hip Details
290
Alternative Valley Hip Detail
Air seal - 8mm Ø butylrubber sealant
Purlin
Hip rafter
Cleader angles by steelwork contractor
Galvanised steel support plate
PIR insulation board
GRP in-situ weathering
200mm minimum gap between panels
KS1000 LP/LPCB insulated roof panel
Cleader angle by steelwork contractors
Air seal - 8mm Ø butyl rubber sealant
Edge protection lacquer applied to allpanels cut on site to suit rake angle
Purlin
Membrane lined thermally brokenfactory made gutter with PIR
insulation to 0.25 W/m2K U-Value
Hip rafter
Cover cap
KS1000 LP/LPCBinsulated roof panel
Double sided plastisolcoated flashing
Gun-grade seal at paneljoints inline with 8mm butyl
Building Regulations Part L2 Thermal Data
fmin = 0.85 Ψ = 0.41 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.02 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Building Regulations Part L2 Thermal Data
fmin = 0.94 Ψ = 0.29 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Valley Hip Detail
Roofslope
ENHANCEDENHANCED
STANDARD
STANDARD
2mm external non-thermally brokenfactory made gutter with PIR
insulation to 0.25 W/m2K U-value
Bottom rolled edge of cap isremoved at in-situ GRP
Air seal - 8mm Øbutyl rubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
291
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Hip Detail
Hip Detail
Bead of non curing gun-grade sealant
Cover cap
2 No. runs of non-curing gun-grade sealant
Panels site cut to suit rake angle
Apex dam (Ref: LP1/A)
Purlin
Hip rafter
Internal ridge flashingwith 150mm overlapsealed with Vapourflexor gun-grade sealant
Cleader angle by steelwork contractor
Hip flashing with 150mmsealed butt straps
Rake cut profiled filler sealed topand bottom with gun-grade sealant
KS1000 LP/LPCBinsulated roof panel
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Air seal - 8mm Øbutyl rubber sealant
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.004 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
STANDARD
STANDARD
Alfasbond (FR) canister applied insulation
Mineral fibre insulation
ENHANCED
Outer sheet turned up onsite with roof pitches below 4˚
ENHANCED
Air seal - 8mm Ø butylrubber sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
292
Lean-to Roof Detail
KS1000 MR/LPCB horizontally laid
Panel bearer at 1500mm centres
Air seal - 6mm Ø bead of gun-grade sealant
Outer sheet turned up with roof slopes below 40
Cover cap
Bead of non-curing gun-grade sealant
Profiled filler set back 80 to100mm to prevent bird attack
Building Regulations Part L2 Thermal Data
fmin = 0.42 Ψ = 1.16 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Vertical Cladding
2 No. runs of non-curinggun-grade sealant
Air seal - 8mm Ø butyl rubber sealant
Purlin
Rafter
KS1000 LP/LPCB insulated roof panel
PIR insulation board with Alfasbond (FR)canister applied insulation to fill any gaps ifrequired to maintain continuity of insulation
Internal ridge flashing with 150mmoverlap sealed with air seal -
Vapourflex or gun-grade sealant
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
293
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Lean-to Roof Detail
Hip Detail
Lean to flashing with150mm sealed laps
Lean to flashing with 150mm sealed laps
Ridge flashing with150mm sealed laps
Cover cap
Apex dam (Ref: LP1)
Bead of non-curinggun-grade sealant
Air seal - 8mm Ø butyl rubber sealant
Air seal - continuous bead of gun-grade sealant
150m
m m
in
75m
m m
inco
ver
Purlin
KS1000 LP/LPCB insulated roof panel
2 No. runs of non-curing gun-grade sealant
Internal ridge flashing with 150mm overlapsealed with (FR) seal - Vapourflex or gun-
grade sealant
Building Regulations Part L2 Thermal Data
fmin = 0.96 Ψ = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Profiled filler set back 80 to 100mmto prevent bird attack
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
294
Expansion Joint
Cover Cap Expansion Joint Detail External Capping
Expansion joint flashing sealed 150mm laps
20mm x 3mm butyl rubber sealant
Zed support with 150mm sealed overlap
Expansion joint cover cap
KS1000 LP/LPCB insulated roof panel
Purlin
Rafter
Internal expansion flashing with 150mmoverlap sealed with air seal - Vapourflexor gun-grade sealant
DIM
C
Gap for expansionDIM X
DIM B= =
71.50
DIM A(120mm + DIM X)
25mm
Site applied rock fibre insulation by others
20mm x 3mm butyl rubber sealant
Cleader angles by steelworkcontractor
Slotted holes in purlin or cleatto accommodate expansion
Building Regulations Part L2 Thermal Data
fmin = 0.97 Ψ = 0.05 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.
Air seal - 8mm Ø butylrubber sealant
Air seal - 8mm Ø butylrubber sealant
Note: Max length 4000mmColour to match panel weather sheet
Cap Ref Dim X Dim A Dim B Dim CCAPEX/20 20 140 10 13CAPEX/25 25 145 15 13CAPEX/30 30 150 20 10CAPEX/35 35 155 25 12.5CAPEX/40 40 160 30 15
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
295
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Barrel Vault Rooflight Mounted Off Ridge
Support bearing plate (Ref: LP2)
Profiled filler to centre crowns of rooflight
Support bearingplate (Ref: LP2)
9mm x 3mm butyl rubber sealant
5mm expansion gap
Position of 4 no. main fixings with29mm Ø washers at end lap
Main panel fixing at side profile joint
Single skin GRP barrel vault rooflight system
Double skin GRProoflight system
Single skin GRP barrelvault rooflight system
Cover cap
Bead of non-curinggun-grade sealant
Apex dam (Ref: LP1) 75mm end lap
75mm end lap
GRP barrel vault rooflight systemfixed at 225mm centres with 30mmØ sealed washers
KS1000 LP/LPCB insulatedroof panel
In-situ GRP weather seal
External closure flashing
GRP site applied water deflector
GRP barrel vault rooflight system fixedat 225mm centres with 30mm Ø sealed
washers
5mm expansion gap
Main panel fixing at side profile joint
Barrel Vault End Lap
Barrel Vault End Lap
Double skin GRP rooflight system
Cover cap overGRP weather seal
Centre crowns of rooflightcut back to accept panelend lap (factory formed)
9mm x 3mm butylrubber sealant
2 No. runs of non-curing gun-grade sealant
Position of 4 no. main fixings with29mm Ø washers at end lap
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
296
Barrel Vault Rooflight Mounted Off Ridge
Barrel Vault Side Lap Detail
Self tap screw with 30mm Øwashers at 255mm centres,stitched to galv. support angle
Continuous 1.6mm thick galvsteel angle for rooflight fixingsbulb type rivets at 300mmcentres (Ref: LP3)
Single skin GRP barrel vault rooflight
20mm x 3mm butyl rubber sealant
KS1000 LP/LPCB insulated roof panel
Main fixing at purlin locations
Double skin GRP rooflight system
1000mm
Continuous 1.6mm thick galv. steel zed support for
rooflight fixings stitched to panelat 200mm centres (Ref: LP5)
50mm Vapourflex tape or similar2 runs of 20mm x 3mm butyl rubber
sealant between top & bottom galv. support
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
297
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Section A-A Section B-B
Barrel Vault Rooflight Mounted Mid Slope
Plan View of Upslope Detail
KS1000 LP cover cap
KS1000 LP roof panel system
Panel side joint
Panel side joint cuton site to allow waterto drain around panel
GRP water deflector
End of roof panel
End of panel joint
Barrel vault rooflight system
Ribs of rooflight
1000mmPanel centre line to centre line of joint
Direction ofrain water
A A
B
B
To ridge
To eaves
In-situ GRP weathering sheetcomplete with water deflector
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
298
GRP Integral Rooflights Factory AssembledOver 4° – Roof Slope
Rooflight to Intermediate Detail
Rooflight Side lap - Fastener Location Detail
Position of 4 No. main fixingswith 29mm Ø washers
High density filler
Triple skin GRProoflight system
Cover cap snaps on without external fixingsNote: Position cap on rooflight side first
KS1000 LP/LPCB insulated roof panel
Triple skin GRP rooflightsystem
Cover caps1000mm
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
299
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
GRP Integral Rooflights Factory AssembledOver 4° – Roof Slope
5mm expansion gap
9mm x 3mm butyl rubber sealant
Triple skin GRPintegral rooflight system
High density filler
75mm end lap
Position of 4 No. main fixings with29mm Ø washers at end laps
Support bearingplate (Ref: LP2)
Cover cap
Main panel fixingsat side profile joint
KS1000 LP/LPCBinsulated roof panel
End lap Detail (Panel to GRP Rooflight)
End lap Detail (GRP Rooflight to Panel)
Position of 4 No. mainfixings with 29mm Øwashers at end laps
9mm x 3mm butyl rubber sealant
Main panel fixings atside profile joint
KS1000 LP/LPCBinsulated roof panel
75mm end lap
Support bearing plate (Ref: LP2)
Cover cap
5mm expansion gap
Triple skin GRP integralrooflight system
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
300
Roof Ventilator Mounted Off Ridge
Detail Through Ridge
EPD
M fo
amru
bber
tape
ther
mal
bre
ak
20m
m x
3m
mbu
tyl r
ubbe
rse
alan
tSq
uare
or r
ecta
ngul
arve
ntila
tor b
y ot
hers
EPD
M fo
am ru
bber
tape
ther
mal
bre
ak
Spec
ial p
rofile
d fill
erse
aled
top
and
botto
m
KS10
00 L
P/LP
CB
insu
late
d ro
of p
anel
Rid
ge fl
ashi
ng
Inte
rnal
ridg
efla
shin
g
Air s
eal -
8m
mØ
but
yl ru
bber
seal
ant
Gal
vani
sed
chan
nel f
ram
ing
to p
erim
eter
of o
peni
ng
PIR
insu
latio
n bo
ard
with
alfa
sbon
d (F
R)
cani
ster
app
lied
insu
latio
n to
fill
any
gaps
if re
quire
d to
mai
ntai
n co
ntin
uity
of in
sula
tion
Air s
eal -
8m
m Ø
but
ylru
bber
sea
lant
PIR
insu
latio
n bo
ard
with
alfa
sbon
d(F
R) c
anis
ter a
pplie
d in
sula
tion
tofill
any
gap
s if
requ
ired
to m
aint
ain
cont
inui
ty o
f ins
ulat
ion
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
301
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
Roof Ventilator Mounted Off Ridge
Cross Section Through Roof
EPDM foam rubber tape Roof Ventilator
20mm x 3mm butyl rubber sealant
Verge zed support sealed 150mm laps
20mm x 3mm butyl rubber sealant
Air seal - 8mm Ø Butyl rubber sealant
PIR board insulation site applied alfasbond firerated (FR) canister insulation to fill any gaps ifrequired to maintain continuity of insulation
Galv. channelframing to
perimeter ofopening
Purlin
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
302
Insulated Flues & Curb Details
Penetration Panels
KS1000LP/LPCBinsulated roof panel
W+25
W+25
Factory made GRP curbedinsulated upstand with in-situ curb weathering
In-situ GRP is taken overbatten cap on down side
Cap replaced afterweathering with the bottomrolled edge of cap removed
at in-situ GRP
Typical Side Section
Flue fixing and final seal by others
Flue fixing and final seal by others
Vapour seal by others
In-situ GRP weathering
25mm
25mm
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
303
KS
100
0 L
P/C
R R
oof
Con
stru
ctio
n D
etai
ls
End Lap Detail
Curved Roof Panel Details
Cover cap
75mm factory
formed joint
Minimum of 300mm between panel
end lap and cover cap end lap
10mmMax
25mm
75mm 75mm
Snap-on cover cap over lower cover cap
End of cover cap pointed with mastic
Factory fitted endlap stitching plate
End lap fixing/stitching screw
18mm x 4mm U sectionbutyl rubber sealant
Continuous bead ofgun-grade sealant
2 runs of non-curing gun-grade masticto side joint
Curved Roof Panel Layout Sequence
Ridge panel with end lapat each panel end
Downslope
Upslope
Panel 2(Crown)
Panel 1(Eaves)
Panel 3(Eaves)
Building width of between 70m to 100m approx.
Panel length (L)
Minimum 150m radius (R)
Lap angle minimum1.5˚ after deflections
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info
304
Component Details
6mm holes
6mm holes
948
6524
53˚
900
218 167 65 24218167
25 25
15
30
10 1090°
127°
24
24
24
1.6
1.6
*
90°1.5
24
30
120
33
10
6mm holes
25
15
30
Apex Dam (Ref. LP1)(To suit 25mm filler)
(Ref. LP1) (Ref. LP1/A)
Support Closure Plate (Ref. LP2)
Note: All dimensions in millimetres *Angle determined by Brett Martin to suit curvature of rooflight
Material: Galvanised steel substrate with double sided Plastisol HP200 coating
Material: Pre-galvanised steel
LP1/A supplied in3000mm lengths,rake cut on site.
10
LP3 - Galvanised Steel LP5 - Galvanised Steel
33
For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info