PRODUCT DATA BK Connect Core Suite of Applications Data Viewer Type 8400, Hardware Setup Type 8401, Time Data Recorder Type 8402 and Data Processing Types 8403 and 8404 BK Connect™ is a fully integrated solution for multi‐channel data acquisition (using our industry‐leading LAN‐XI hardware), data processing, data management and reporting. The innovative user interface is easily customized so you can adapt it to the needs of different users within your organization enabling expert users and operator technicians to work together with maximum efficiency and high productivity. The core applications of BK Connect are designed for general‐ purpose sound and vibration engineering. Together they provide a comprehensive set of tools for real‐time measurements and data processing with the flexibility to deal with a wide range of engineering scenarios – from repetitive, standardized testing to complex troubleshooting investigations. Uses and Features Uses • Sound and vibration data acquisition, analysis and reporting • Time data recording • Visualization, editing and audio playback of time data after recording and in preparation for analysis • Display of frequency, rpm and order content of time signals during audio playback • Off‐line analysis (post‐processing) of recorded time data • Batch processing of multiple sets of time recordings • Stationary and non‐stationary FFT, CPB (1/n‐octave), overall (broadband) analysis, order analysis and envelope analysis • Simultaneous parallel analysis with different filter settings, FFT bandwidths, and 1/n‐octave set‐ups • Simple and efficient reporting of results with user‐definable layouts and user‐selectable metadata • General vibration and acoustic analysis • Rotating machinery analysis • Sound quality metrics analysis • Human vibration analysis Features • Single applications for acquisition, recording, batch post‐ processing, and data management and reporting • User interface and data organization optimized to fit your workflows, allowing multiple tests, set‐ups and applications inside a single project • Graphical set‐up of: – Transducers used with the data acquisition hardware (using real or virtual front end) – Data analysis flow through interactive process chains • Embedded reporting using Microsoft® Office products to integrate report writing into the test process • Easy to learn and use, reducing training and test time Upcoming Features • Real‐time CPB (1/n‐octave) monitoring • Network‐based databases • Sharing of test setups using files • Automated multi‐page reporting • Support for measurements and recordings using a head and torso simulator (HATS) and binaural microphones • Updated geometry‐guided measurements with BK Connect Geometry Type 8410

Upload: others

Post on 02-Jun-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

P R O D U C T D ATA

BK Connect Core Suite of ApplicationsData Viewer Type 8400, Hardware Setup Type 8401, Time Data Recorder Type 8402and Data Processing Types 8403 and 8404

BK  Connect™  is  a  fully  integrated  solution  for  multi‐channeldata acquisition (using our industry‐leading LAN‐XI hardware),data  processing,  data  management  and  reporting.  Theinnovative user interface is easily customized so you can adaptit  to  the  needs  of  different  users  within  your  organizationenabling  expert  users  and  operator  technicians  to  worktogether with maximum efficiency and high productivity.

The core applications of BK Connect are designed for general‐purpose  sound  and  vibration  engineering.  Together  theyprovide  a  comprehensive  set  of  tools  for  real‐timemeasurements and data processing with the flexibility to dealwith a wide range of engineering scenarios –  from repetitive,standardized testing to complex troubleshooting investigations.

Uses and Features

Uses• Sound and vibration data acquisition, analysis and reporting• Time data recording• Visualization, editing and audio playback of  time data after

recording and in preparation for analysis• Display of frequency, rpm and order content of time signals

during audio playback• Off‐line analysis (post‐processing) of recorded time data• Batch processing of multiple sets of time recordings• Stationary and non‐stationary FFT, CPB (1/n‐octave), overall

(broadband) analysis, order analysis and envelope analysis• Simultaneous parallel analysis with different filter settings, FFT

bandwidths, and 1/n‐octave set‐ups• Simple and efficient reporting of results with user‐definable

layouts and user‐selectable metadata• General vibration and acoustic analysis• Rotating machinery analysis• Sound quality metrics analysis• Human vibration analysis

Features• Single  applications  for  acquisition,  recording,  batch  post‐

processing, and data management and reporting • User  interface  and  data  organization  optimized  to  fit  your

workflows, allowing multiple  tests,  set‐ups and applicationsinside a single project 

• Graphical set‐up of: – Transducers used with the data acquisition hardware (using

real or virtual front end) – Data analysis flow through interactive process chains 

• Embedded  reporting  using  Microsoft®  Office  products  tointegrate report writing into the test process 

• Easy to learn and use, reducing training and test time

Upcoming Features• Real‐time CPB (1/n‐octave) monitoring• Network‐based databases• Sharing of test setups using files• Automated multi‐page reporting• Support for measurements and recordings using a head and

torso simulator (HATS) and binaural microphones• Updated  geometry‐guided measurements  with  BK  Connect

Geometry Type 8410

Page 2: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

The BK Connect Core Suite

The core applications of BK Connect are: • BK Connect Data Viewer for data management, viewing and reporting• BK Connect Hardware Setup for setting up transducers and front‐end hardware• BK Connect Time Data Recorder for dedicated time data recording and review • BK Connect Data Processing for real‐time measurements and time or function data processing 

Each of these applications is designed as a self‐contained solution for a typical task or set of tasks withintest  and  analysis.  Select  the  module  or  modules  that  will  help  you  perform  the  task,  or  combineapplications to increase functionality and create super‐efficient workflows for quick and easy completionof multiple steps in a sound and vibration test process.

Fig. 1 BK Connect core applications

Licencing that Fits Your NeedsBK  Connect  Data  Viewer  (specifically  Type 8400,  a  free  licence)  is  the  prerequisite  for  all  applicationsexcept BK Connect Hardware Setup. 

All BK Connect core applications have at least one base licence: Data Viewer Type 8400, Hardware SetupType 8401  and  Time Data  Recorder  Type 8402.  The Data  Processing  application  has  two  base  licences:Type 8403 and Type 8404. 

Each  application  also  has  an  advanced  licence,  denoted  by  an  A  in  the  type  number  (for  example,Type 8400‐A), which adds more advanced features to those available in the base licence. Both Data Viewerand  Data  Processing  applications  have  options  for  add‐on  functionality.  The  Data  Viewer  options,Types 8400‐B, C, D, E and F, enable import of different types of file formats, while the Data Processing options,Types 8405‐B, C, D, E, F and G, add analysis calculations and process chain elements to the base set.

The  four  core  applications  can  all  be  used  stand‐alone  or  incorporated  into  the  main  application,BK Connect  Data  Processing.  On  its  own,  Data  Processing  is  purely  for  time  or  frequency  data  post‐processing,  however when  the Hardware  Setup  licence  is  present,  you  can  also measure  in  real  time.When the Time Data Recorder licence is present, you can simultaneously record and post‐process test datato quickly produce your final results and/or reports.

Data reviewfrom previoustesting

Set upacquisitionhardware

Data recordingAcquisition and data processing

Processed data review andcomparison

Reporting

Data Viewer

Hardware Setup Time Data Recorder Data Processing

BK ConnectCore application modules that enablequick and easy testing at each step of the process

170250

2

Page 3: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BK Connect Data Viewer

BK Connect Data Viewer provides tools for working with local databases, defining metadata, performingdatabase searches using metadata, data import and export, flexible data display, and report creation. 

Data Viewer Base and Advanced Licences

BK Connect Data Viewer Type 8400 (free licence)Using Type 8400, you can connect to any BK Connect database, find data using metadata queries, displayand compare data, and prepare reports using Microsoft Office tools. You can also import or export data inthe native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When usedas a team collaboration tool, you can import a database, project or data file from a colleague, view andcompare their data, then create your reports using Microsoft Word or PowerPoint® to share with the restof the team.

Type 8400 tools include:• File Import: Import of time and function data files from BK Connect and PULSE Reflex (*.bkc and *.csv)• Metadata Editor: Set up metadata for storage to a BK Connect database• Project Browser: Manage data through this essential data management tool. Functionality includes data

search, filter, selection and editing of data descriptors• Graphical displays: Drag and drop data into a display; copy and paste the displays into a report• My Data: Organize your data any way you wish. Copy data from any application in the current project, or

drag & drop data from other projects in the database via the Search tool• Reporting: The Report Organizer gives a complete overview of available templates and generated reports.

Create reports from supplied templates or use an existing report to create a new, customized template

Fig. 2 BK Connect Data Viewer provides the fundamental framework and data management components of BK Connect

Data reviewfrom previoustesting

Set upacquisitionhardware

Data recordingAcquisition and data processing

Processed datareview andcomparison

Reporting

Data Viewer

BK Connect Data ViewerThe base application modules that provideproject and data management, basic data comparison and integrated reporting

170251

3

Page 4: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

All functionality available in Type 8400 stays intact as you add applications on top of it.

BK Connect Data Viewer (advanced) Type 8400‐AType 8400‐A adds advanced data viewer and reporting features to the base Type 8400 including: • Data Table Viewer: A highly flexible tabular presentation of large amounts of data with powerful filtering

and sorting tools and automated reporting• Result Matrix  Viewer:  A  structured  overview  of  results  from  a  number  of  tests,  making  selection,

comparison and reporting very easy• Scratchpad Calculator: Standard mathematical and statistical operations can be performed on 2D and 3D

functions. The graphical displays in the Scratchpad provide basic reporting capabilities 

Fig. 3 The Result Matrix Viewer showing five sets of results compared by selecting individual cells in the matrix. The resulting graphical displays are automatically overlaid and the overall metric results are presented in tabular form

Data Viewer OptionsFive Data Viewer options increase your file format import and export options. All of these modules requirea Data Viewer Type 8400 licence.

BK Connect Native File Importers Type 8400‐BThe following tools and components are added:• File import of any format used natively by Brüel & Kjær applications

– from PULSE Time Data Recorder, PULSE LabShop and PULSE Reflex Measurements: *.pti (time data)– from PULSE LabShop:*.dat (time data, must also have the ancillary *.rec file), PULSE ASCII *.txt (time

and function data)– from Test for I‐deas: *.ati (time data), *.afu (function data)– universal files: *.unv, *.uff (time and function data)– wave files: *.wav (time data)

• Import from LabShop and Import from PDM: Interfaces that allow you to import your saved data directlyfrom PULSE LabShop or PULSE Data Manager. You can open a PULSE project (*.pls) directly in BK Connectand connect to LabShop’s Measurement or Function Organizer

• Export to Excel: In addition to exporting data to file or exporting entire projects, you can also export datato a Microsoft® Excel® workbook

BK Connect External File Importers Type 8400‐C• File import of external formats 

– from ASAM‐ODS: *.atfx (time and function data)– from DSPCon:*.DATX (time data)– from Head Acoustics: *.hdf, *.dat (time data)– from HBM Somat: *.sie (time data)– from MTS: *.rpc (time data)– from HP analyzers: *.sdf (standard data format for time and function data)

4

Page 5: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BK Connect Finite Element Interface Types 8400‐D, E and FImport of finite element (FE) models can include, apart from geometry data and modal data, also reducedmass matrices (Nastran or Abaqus). This allows for animation of FE modes as well as correlation of finiteelement  analysis  (FEA)  results  with  test  results.  FE  models  can  be  imported  as  UFF  files  or  with  thefollowing options, from Nastran, Ansys or Abaqus: • File import of Nastran FE models: Available with Nastran Interface Type 8400‐D• File import of Ansys FE models: Available with Ansys Interface Type 8400‐E• File import of Abaqus FE models: Available with Abaqus Interface Type 8400‐F

BK Connect Hardware Setup

BK Connect Hardware Setup allows you to connect to a front end and prepare the physical set‐up. You canuse the Hardware Setup application stand‐alone with your LAN‐XI front‐end system to quickly and easilyassign  all  of  your  transducers  via  TEDS’  automatic detection or manual  drag‐and‐drop.  The HW Set‐upTable provides a quick overview of the hardware configuration including signal names, DOF information,transducer calibration information and front‐end settings. This is coupled with the Hardware Matrix whichprovides  you  with  an  interactive  graphical  display  of  the  front  end,  including  real‐time  display  of  theLAN‐XI  LED status  rings, enabling you  to understand  the  state of  your  instrumentation  from  inside  theBK Connect  user  interface.  Selections  in  the Hardware Matrix  are  instantly  reflected  in  the HW Set‐upTable, which makes it very easy to handle large channel counts as the channel table scales automatically tothe selection in the matrix.

The real‐time monitors in BK Connect Hardware Setup include time, level, FFT and spectrogram displays togive you confidence  in your  instrumentation set‐up and ensure you are ready to start acquiring data. Astart/stop recorder is included to provide a simple data acquisition option.

You can also connect to a virtual front end based on a known hardware configuration. This enables you toprepare in advance for a test without having to connect to the physical front end and tie up test resources,which is especially useful when preparing for a large‐scale test with many channels.

Hardware Setup Base and Advanced Licences

BK Connect Hardware Setup Type 8401Type 8401  allows  connection  of  up  to  two  front‐end modules.  Two  Type 8401  licenses  can  be  stackedtogether to provide unlimited module access. Once connected: • Create and manage transducers in the transducer database• Assign transducers to front‐end channels (assuming no TEDS)• Perform transducer verification (calibration)• Real‐time monitor displays• Simple start/stop recording to a .bkc file

You can manage  the set‐up using  the  real‐time monitor display, which provides  instant and continuousvisual feedback on signals coming in to the front end. The displays start immediately upon connecting tothe front end, so no initialization is needed and start‐up is extremely fast.

Data reviewfrom previoustesting

Set upacquisitionhardware

Data recordingAcquisition and data processing

Processed datareview andcomparison

Reporting

Hardware Setup

BK Connect Hardware SetupApplication modules forgraphics-based set-up of your data acquisition hardware

170253

5

Page 6: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Fig. 4 Hardware Setup

BK Connect Hardware Setup (advanced) Type 8401‐ABK  Connect  Hardware  Setup  (advanced)  Type  8401‐A  adds  the  ability  to  measure  with  an  unlimitednumber of LAN‐XI modules, as well as one‐button accelerometer mounting check to check the mountedresonance state of your accelerometers*. This is an invaluable aid, especially in high‐channel count tests,to ensure that all accelerometers remain firmly mounted to the test structure throughout the test process.You can also perform a detailed verification of the performance of your LAN‐XI hardware modules usingthe Module Verification tool. The tool checks that the electrical noise, distortion, input range levels andthe high pass filter setting of the modules are still within the manufacture’s specification, eliminating asource of uncertainty in your measurement chain.

Fig. 5 Hardware Setup (advanced) showing recording in the Monitor

Virtual Hardware Setup (free of charge)BK Connect Virtual Hardware Setup Type 8401‐V is a free licence that lets you use any physical front‐endconfiguration that has been saved as a ‘virtual front end.’ The file can be used to assign transducers andconfigure the hardware set‐up table as if you were using the actual physical hardware, thus allowing youto set up your test at your desk rather than in the lab or out in the field. 

* Requires accelerometers which support the accelerometer mounting check function.

6

Page 7: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BK Connect Time Data Recorder

BK Connect Time Data Recorder is designed for fast, efficient, flexible recording. Start and stop manuallywith a click of a button, or set up signal or speed triggers for automated recordings. 

Time  Data  Recorder  is  closely  linked with  the  real‐time monitor  displays  ensuring  that  no  event  goesunnoticed whilst recording is in progress. Both Data Viewer Type 8400 and Hardware Setup Type 8401 arerequired to use Time Data Recorder.

Time Data Recorder Base and Advanced Licences

BK Connect Time Data Recorder Type 8402When used as a stand‐alone application, Time Data Recorder provides  fast and efficient  recording withpost‐recording  verification.  When  used  inside  the  Data  Processing  application,  it  becomes  part  of  asophisticated recording, measurement and post‐processing workflow.

Type 8402 provides a number of time data recording tools and features:• Flexible triggers allowing different options for triggered start and stop of a recording – ideal for ‘set up &

leave’ scenarios• Trigger delay or pre‐delay gives the flexibility to record unpredictable transient events• Two recording modes: 

– Multiple mode enables a fixed number of sub‐recordings to be made in a single recording process– Circular mode enables a fixed number of sub‐recordings to be continuously updated so you can record

for a fixed period of time and stop on a signal trigger event, for example recording what happens beforean unpredictable event

• Markers allow you to indicate events during recording that can later be used as an aid to post‐processing.These markers can be edited in the Time Review task (available with Type 8402‐A)

• One‐touch operation via hot keys for use when normal operation is difficult, for example, in a movingvehicle

• A documented API for external applications, or smart device apps, to control key functions and obtainstatus information 

• Metadata definitions and event markers are saved in the recording file for use during post‐processing andreporting

Data reviewfrom previoustesting

Set upacquisitionhardware

Data recordingAcquisition and data processing

Processed datareview andcomparison

Reporting

Time Data Recorder

BK Connect Time Data RecorderApplication modules forrecording time data in the field or lab for immediate or later processing

170256

7

Page 8: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Fig. 6 Time Data Recorder

BK Connect Time Data Recorder (advanced) Type 8402‐ABK Connect Time Data Recorder (advanced) Type 8402‐A adds a Time Data Review analysis task with whichyou can check the quality of your recordings by playing them back, listening to individual channels, andtrimming them to remove unwanted data. You can also edit the metadata or markers, if needed, so thatthe recordings are fully prepared and error free, for later post‐processing.

Fig. 7 Time Data Recorder (advanced) showing the Time Data Review task

8

Page 9: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BK Connect Data Processing

BK  Connect  Data  Processing  brings  together  a  comprehensive  set  of  signal  analysis  tools  for  post‐processing sound and vibration data. Central to data processing is the process chain – a graphical tool forsetting up  the analysis process using  individual,  separately  configurable elements  for  filtering, analysis,display  and  storage  of  results.  A  chain  is  made  up  of  selected  elements  to  form  a  complete  analysisprocess. You can run analysis on one or multiple data sets or save the chain for later re‐use. 

On  its own,  the Data Processing application  is only  for post‐processing  time or  function data. With theaddition  of  Hardware  Setup  and  Time  Recorder  licences,  the  application  expands  to  include  real‐timespectral measurements and recording.

The Data Processing application’s unique capability to integrate with the other core applications as well asBK  Connect  Geometry  Type 8410  and  BK  Connect  Structural  Measurements  –  Hammer  and  ShakerType 8411, makes it a complete yet flexible solution. You can configure the user interface, properties andtasks to suit your needs or mode of working, then save the workflow as a template.

Data Processing Base and Advanced Licences as Stand‐alone SolutionsThere are two base licenses: • Data  Processing  Type 8403  provides  a  simplified,  template‐driven  mode  of  operation.  It  is  a  basic

application  intended for those who need standard time data processing and/or measurement with asimple click‐and‐go interface

• Data  Processing  Specialist  Type 8404  provides  a  fully  customizable,  expert mode  of  operation.  It  isintended for advanced users who need the flexibility of determining all the functions and parameters oftheir test set‐up

Types 8403 and 8404 contain  the  same basic  set of  signal processing  functions,  including  time domainfilters, FFT analysis and overall analysis, which means the analysis functionality is identical. You can alsoadd  the  same  analysis  options  (Types 8405‐B,  C,  D,  E,  F  and  G)  to  the  base  licences.  By  adding  theadvanced module, Type 8404‐A, to Type 8404, you add the features of Type 8403 allowing you to validateany templates you create before they are used in Type 8403.

Data reviewfrom previoustesting

Set upacquisitionhardware

Data recordingAcquisition and data processing

Processed datareview andcomparison

Reporting

Data Processing

BK Connect Data ProcessingApplication modules forcomprehensive testing — from real-time measurements to post-processing

170259

9

Page 10: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Fig. 8 The basic components of BK Connect Data Processing

BK Connect Data Processing Type 8403Type 8403 contains the following features:• Standard Processing Setup task – View the predefined process chains and adjust available parameters • Standard Processing task – Perform automated, batch processing of data: Any data in the active set‐up is

run through one or more predefined process chains in different set‐ups– Time data analysis: FFT, FFT vs time, overall, overall vs time, and tachometer (rpm or speed) vs time – Pre‐processing elements: Weighting, filtering, integration, etc.

• Standard Measurements task: Perform real‐time spectral measurements (with the appropriate HardwareSetup licence for front end connection). Set up triggering, bandwidth, resolution, number of averages,selection of reference signals, and output function types. You can validate the set‐up using the real‐timemonitors. Results are automatically sent to the Standard Processing task 

• Immediate display and storage of analysis results• Automated reporting 

Fig. 9 Data Source Management and Done Management tools allow you to automate your workflow. If Done Management has been defined in a task, you can simply click the check mark to go directly to the next step in the workflow

With Type 8403 you can run a predefined template, then import data, adjust the analysis parameters asnecessary and process with a single click – perfect for repetitive testing. 

10

Page 11: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BK Connect Data Processing Specialist Type 8404Type 8404 has the following features:• Time  Data  Processing  task  which  provides  the  same  pre‐processing  and  analysis  elements  that  are

available in Type 8403, but allows you to create a process chain as needed and save process chains for re‐use. In addition, the task includes the Time Editor for fast, efficient display and audio playback of time data,intelligent selection of signal groups and time ranges (regions), spectrogram display and interactive filters

• Function Data Processing task for post‐processing and performing calculations on spectra via a process chain• Automatic display and storage of analysis results• Automated reporting 

Process  chains are highly  versatile as  they allow  for multiple parallel analyses  in one  run,  for example,analysing vibration data at a different bandwidth than your acoustic data. Individual process chains can bestored for later use, which means that there is no need to repeat the set‐up after the first time – simplydrag‐and‐drop  a  previously  stored  chain  into  the  Data  Processing  pane.  It  is  also  possible  to  attach  anumber of regions to a chain and run the analysis in batch mode, thus analysing multiple input regions inone operation.

Unlike  Type 8403,  Type 8404  gives  you  the  freedom  to  adapt  the  analysis  to  the  test  scenario  byinteractively selecting the process elements in your process chain. You can preview the time data in theTime Editor and select regions of interest to post‐process. 

Using BK Connect’s  ‘favourites’ concept, you can decide which  features are visible  in a saved template.This  includes  the  properties  of  each  process  chain  element.  For  example,  you  can  pre‐define  a  set  ofproperties then hide them so that the template user need only define specific parameters, while othersare set beforehand. You can define the workflow, setting where the template navigates to once a task iscompleted, and include notes to guide and inform the user about each task.

Like Type 8403, you can view results and generate reports quickly and easily. 

Fig. 10 Type 8404 using ‘favourites’ to hide parameters in a template for use in Type 8403

BK Connect Data Processing Specialist (advanced) Type 8404‐ABK  Connect  Data  Processing  Specialist  (advanced)  Type 8404‐A  adds  the  Standard Measurements  andStandard Processing tasks to Type 8404 allowing the expert user a simplified workflow when under timepressure, or enabling a set‐up to be validated for later use in Type 8403.

Data Processing Base and Advanced Licences as an Integrated Team SolutionThe  Data  Processing  application  is  specially  designed  as  a  completely  integrated  solution  for  teamsproviding  targeted  usability  for  each  standard  profile  in  an  acoustic  and/or  vibration  test  team:  forexample, the test manager, specialist, test engineer and operator.

11

Page 12: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

For Test Engineers and Operators: BK Connect Data Processing Type 8403Types  8403  and  8404  have  similar  tools  for  measurement,  data  processing,  display  and  reporting,however, Type 8403 is designed for use with templates containing ready‐made set‐ups and workflow. Thisis  perfect  if  your  only  task  is  to  run  a  simple  process:  a  predefined  measurement  or  recording,  dataprocessing with fixed analysis settings, or repetitive recording and analysis.

Type 8403 users cannot create  templates or process chains,  therefore  they must  run with a configuredtemplate containing at least one set‐up for hardware and analysis.

The  template and predefined  set‐up  is made using Type 8404 and, depending on  the  intentions of  thetemplate designer, you may be allowed the flexibility to adjust many processing parameters, or restrictedto  a  few  or  no  editable  parameters.  In  the most  extreme  operator  scenario,  the  channel  settings  andanalysis  parameters  may  be  completely  locked  and  invisible  leaving  you  to  concentrate  solely  oncontrolling the physical test set‐up, operating parameters and measurements.

For Specialists: BK Connect Data Processing Specialist Type 8404To edit and configure a Type 8403 interface, you will need to use a Type 8404 licence. With Type 8404, youcan determine which tasks are included and which, if any, analysis parameters can be seen and edited.

A template can contain a number of different tests and set‐ups, each with its own step‐by‐step workflow,so it can encompass an entire test programme if needed. You can customize the workflow, for example, by:• Defining the task in which to start• Defining which task comes next when the current task has been completed• Defining which features are visible to the operator• Defining which of the set‐up parameters can be edited• Including notes, diagrams and photographs to guide the operator through each step of the workflow

In  a  multi‐user  test  scenario,  typically  only  one  Type 8404  licence  (installed  on  the  specialist  or  testdesigner's PC) is needed for a group of Type 8403 users (the operators or technicians).

For Specialists: BK Connect Data Processing Specialist (advanced) Type 8404‐AA Type 8404‐A licence allows you to validate the measurement and processing templates that you havecreated for Type 8403 users. It is useful in ensuring that the correct user interface, parameters and workfloware presented when running in Type 8403’s automated mode without you having a Type 8403 licence. 

Data Processing Options with Type 8405To Types 8403 and 8404 you can add the following options:• Type  8405‐B:  Advanced  frequency  analysis  including  envelope  and  demodulation  analysis,  time

correlation analysis and IIR filtering• Type 8405‐C: CPB (1/n‐octave) analysis according to IEC, DIN and ANSI standards• Type 8405‐D: Process chain calculations• Type 8405‐E: RPM‐based processing and order analysis using fixed bandwidth FFT• Type 8405‐F: Tracked FFT and order analysis• Type 8405‐G: Calculation of sound quality metrics

Advanced Frequency Analysis with Type 8405‐BType 8405‐B adds Envelope, Demodulation and Time Correlation Analysis to the list of available processchain elements. 

Envelope  analysis  is  a means  for  understanding  the  amplitude modulation  of machine  vibration, mostoften used to diagnose fault modes in bearings and gear trains. Time correlation analysis enables you tofind repeated patterns between signals in the time domain, for example when a sound takes more thanone path to reach the receiver.

The Demodulator element is for amplitude or phase demodulation of signals based on a given reference(modulation)  frequency.  Amplitude  demodulation  is  part  of  the  process  for  envelope  analysis  andseparating it from the FFT analysis enables greater flexibility of analysis when deciding how to process theoutput demodulated signal. Phase demodulation enables you to study frequency perturbations of a given

12

Page 13: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

reference frequency; for example, the fundamental frequency of a rotating shaft where the perturbationsrepresent angular (or torsional) vibration superimposed on the carrier rotating frequency.

Also  included  is  a pre‐analysis  element  for  time domain‐based  Infinite  Impulse Response  (IIR)  filtering,including low‐pass, high‐pass and combined low‐ and high‐pass filters with control of filter order and filterdesign options of Butterworth or Chebyshev.

Standardized CPB Option with Type 8405‐CConforming to IEC, DIN and ANSI standards, Type 8405‐C provides 1/1‐, 1/3‐, 1/6‐, 1/12‐ and 1/24‐octaveanalysis with digital filters and simultaneous calculation of overall level, both weighted and unweighted.Acoustic weighting can be applied to the spectrum itself and min./max. holds on individual, single, overall,or overall weighted bands.

Fig. 11 CPB (here 1/3‐octave) analysis follows the same simple workflow as FFT, order and overall analysis. The displays show A‐weighted 1/3‐octave vs time (left) and the 125 Hz band level vs time overlaid on total level. The cursors are synchronized between the displays

The CPB option adds two process chain elements:• CPB• CPB vs time

Calculations in the Process Chain with Type 8405‐DType 8405‐D adds advanced calculation functionality including:• Calculation elements  in the process chain for function statistics, function operators, scaling with unit

conversion, frequency weighting, complex math, statistics and function smoothing. These elements canbe included in time data processing and function data processing 

• Batch Statistics element in the process chain allowing function statistics – min., max. and mean – to becalculated on  results  from different  time  input  regions and, optionally, based on  selected metadata,enabling recordings from different tests to be processed simultaneously in one process chain

13

Page 14: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Fig. 12 Calculation sequences can be included in the Process Chain with Type 8405‐D. In this example, a vibration dose value (VDV) calculation, including human vibration weighting, is performed on acceleration time data

Order Analysis with Type 8405‐EType 8405‐E adds fixed bandwidth FFT‐based order analysis to Type 8403/8404. When a tachometer pulsetrain is available, the analysis can be set up to include rpm as a time‐varying tag to 3D spectral maps. As analternative to rpm, the tachometer conditions and profile can be defined with position (unit: m), speed(m/s) or vehicle speed (km/h) (ft, ft/s or mph for imperial units).

Fig. 13 In this run‐up example, the focus is on the fourth order level, in each ear, of the recorded binaural sound

With Type 8405‐E, these additional elements are available in the process chain:• FFT signal vs rpm and FFT system vs rpm• Order extraction (order slices extracted from spectra)• CPB vs rpm • Overall vs rpm

Additional Time Editor features include:• Tachometer pulse train synthesis from speed profiles, for example from CAN data, voltage‐proportional‐

to‐speed conditioning equipment, or the graphical auto‐tracker• Tachometer repair: Smoothing and correction for pulse drop‐out or multiple pulses

14

Page 15: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Additional analysis tasks are available for graphical (interactive) order slice extraction and auto‐tracking togenerate an rpm profile from FFT vs time outputs. An auto‐tracked speed profile can then be converted toa tachometer pulse train using the synthesis utility.

Order Tracking with Type 8405‐FFig. 14 In this example, a distinct tone/whine is heard during the run down and is picked up in one of the acceleration signals. The spectrogram focuses on the order of interest, a zoom order analysis is performed, and the tracked order is displayed against total level. The entire workflow is visible in a single view

Type 8405‐F adds tracked resampling to basic Type 8403/8404: Streamed data is resampled according tothe instantaneous rpm value from a given tachometer signal. 

Tracked order  analysis  is  recommended  for  high accuracy  analyses of  high order  numbers occurring  inrotating machinery equipment such as gearboxes, transfer boxes, differentials, power trains, turbines andaircraft engines.

With Type 8405‐F, these additional elements are available in the process chain:• Order spectrum• Order spectrum vs time• Order spectrum vs rpm• Order extraction (order slices extracted from order spectra)

Additional Time Editor features include (same as Type 8405‐E):• Tachometer pulse train synthesis from speed profiles, for example from CAN data, voltage‐proportional‐

to‐speed conditioning equipment, or the graphical auto‐tracker• Tachometer repair: Smoothing and correction for pulse drop‐out or multiple pulses

15

Page 16: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Sound Quality Metrics with Type 8405‐GFig. 15 Sound quality metrics are integrated into the same processing framework as all other analysis types in BK Connect Data Processing

Type 8405‐G adds sound quality metric calculations. Two specialized process chain elements enable thecalculation of metrics as either overall values/spectra or as values/spectra versus time. 

The following sound quality metrics are included:

The latest ISO 532 2017 Loudness standard, parts 1 and 2, is supported in addition to past standards.

• Articulation Index (AI) • Sharpness

• Stationary Loudness • Fluctuation Strength

• Time‐varying Loudness • Roughness

• Statistical Loudness • Tone‐to‐Noise Ratio

• Loudness Level • Prominence Ratio

• Binaural Loudness • Tonality

16

Page 17: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Specifications – BK Connect Core Applications

This Windows®‐based analysis software is delivered via installation media (DVD or USB). The licence is either: node‐locked to a PC host ID or dongle; or floating, locked to a network server 

System 

PC SYSTEM REQUIREMENTS• Microsoft® Windows® 10 Pro or Enterprise (x64) with either Current Branch (CB) or Current Branch for Business (CBB) servicing model; or Windows® 7 Pro, Enterprise or Ultimate (SP1) (x64) operating systems

• Microsoft® Office 2016 (x32 or x64) or Office 2013 (x32 or x64)• Microsoft® SQL Server® 2014 Express (SP2) (included in installation), Microsoft® SQL Server® 2014 (SP2), SQL Server 2012 R2, SQL Server 2008 or 2008 R2 Express Edition SP1

RECOMMENDED PC SYSTEM• Intel® Core™ i7, 3 GHz processor or better• 32 GB RAM• 480 GB Solid State Drive (SSD) with 20 GB free space, or better• 1 Gbit Ethernet network* • Microsoft® Windows® 10 Pro or Enterprise (x64) with CB • Microsoft® Office 2016 (x32)• Microsoft® SQL Server® 2014 (SP2)• Screen resolution of 1920 × 1080 pixels (full HD)

FRONT ENDRequired for real‐time measurements and recordingFront‐end Support: One or more LAN‐XI data acquisition modules (stand‐alone or in frame)

Software Prerequisites

* A dedicated data acquisition network (LAN or WAN) is recommended. A network that only handles data from the front end improves the stability of 

the data

Software Prerequisites Software  Prerequisites

BK Connect Data Viewer Type 8400 See System 

Specifications

BK Connect Time Data Recorder Type 8402 Types 8400 and 

8401

BK Connect Data Viewer (advanced) Type 8400‐A Type 8400 BK Connect Time Data Recorder (advanced) Type 8402‐A Type 8402 

BK Connect Native File Importers Type 8400‐B Type 8400 BK Connect Data Processing Type 8403 Type 8400 

BK Connect External File Importers Type 8400‐C Type 8400  BK Connect Data Processing Specialist Type 8404 Type 8400 

BK Connect Nastran Interface Type 8400‐D Type 8400  BK Connect Data Processing Specialist (advanced) 

Type 8404‐A

Type 8404 

BK Connect Ansys Interface Type 8400‐E Type 8400 BK Connect Advanced Frequency Analysis Option 

Type 8405‐B

Type 8403 or 

8404 

BK Connect Abaqus Interface Type 8400‐F Type 8400 BK Connect CPB Option Type 8405‐C Type 8403 or 

8404

BK Connect Hardware Setup Type 8401 See System 

Specifications

BK Connect Calculations Option Type 8405‐D Type 8403 or 

8404

BK Connect Hardware Setup (advanced) Type 8401‐A Type 8401  BK Connect Order Analysis Option Type 8405‐E Type 8403 or 

8404

BK Connect Virtual Hardware Setup Type 8401‐V See System 

Specifications

BK Connect Order Tracking Option Type 8405‐F Type 8403 or 

8404

BK Connect Sound Quality Metrics Option Type 8405‐G Type 8403 or 

8404

17

Page 18: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Specifications – BK Connect Data Viewer Type 8400BK Connect Data Viewer Type 8400 is the prerequisite licence for all applications (except for Hardware Setup applications). All other applications add functionality to the prerequisite licence

Features• Support of BK Connect file formats only• Project database based on Microsoft® SQL Server®• Powerful data viewing• User‐controllable use of metadata for sorting and filtering displayed data• Fast, template‐based automated reporting to Microsoft® Word and PowerPoint®

Import/ExportThe following data file formats are supported:• .bkc (BK Connect native format) – both function and time data• .csv (based on a predefined format): – Recording data (even abscissa time domain)– 2D complex‐valued frequency domain data– 2D real‐valued frequency domain data (FFT and CPB)

PROJECT FILE EXPORT AND IMPORTExport a project to an external “transport” file (*.BKConnectTemplate or *.BKConnectProject), with or without imported or processed data, for archiving outside the database, sharing with other BK Connect users, capturing a snapshot of a particular state, or creating a project template 

Data DisplayDisplays enable viewing and comparison of measurements and results. Data is dragged‐and‐dropped to/from the Project Browser. The User‐defined Display task is the container for displaying graphical results

GRAPH TYPESDisplay of functions in a range of graph types including:• Waterfall• Waterfall (step)• Colour contour (3 variants)• Campbell diagram• Bar• Line• Curve• Curve (step)• Overlay• Overlay (all)• Multi‐valueSuperimposed Graphs: A number of functions can be superimposed on the same curve graph

AXES• X‐axis Scale: Linear, logarithmic and CPB• Y‐axis Scale: Linear, logarithmic and dB• Z‐axis Scale: Linear and logarithmic

COMPLEX DISPLAYS• Real• Imaginary• Magnitude• Phase• Nyquist• Bode

SPECTRAL UNITS• Root mean square (RMS)• Power (PWR)• Power spectral density (PSD)• Root mean square spectral density (RMSSD)• Energy spectral density (ESD)• Peak (Peak)• Peak‐to‐Peak (PkPk)

ACOUSTIC POST‐WEIGHTINGA‐, B‐, C‐, D‐, L‐weighting

j WEIGHTING1/j2, 1/j, 1, j, j2 (single and double integration and differentiation)

CURSOR TYPESDepending on the display type, the following are available:• Main• Delta• Order• Reference• Harmonic• SidebandAlignment: Cursors in different displays can be synchronized to allow the changes to one display to be reflected in other displays showing the same or different functions

CURSOR READINGSThe cursor values that can be read:• Acoustic levels• Corrected frequency• Cursor indices and values• Delta• Delta/total• Max. and min. values• Nearest harmonic• Nearest sideband• Reference• Resonance• Reverberation• Slice definition• Status• Total

ReportingA separate reporting task enables templates to be created in Microsoft® Word, Excel® or PowerPoint®. This is particularly useful for standardized reporting

Data ManagementData management is based on a data model that interacts with a Microsoft® SQL Server® database. Connection to the last used database is automatic upon starting BK Connect. However, the user can connect to a different database at any time during a session. Only one database can be connected at a time.Local database with each BK Connect installation; optionally accessible via a BK Connect service, one user at a time, over a company network

DATABASE HANDLINGDatabases can be created, deleted, backed up and restoredDatabase Migration Tool: Tool that allows users to start application using an SQLite database and at a later point migrate data to an SQL Server solution

DATA STORAGE (of data files, report templates, pictures) Uses a filefarm (on disk) referenced by the database. File sizes limited by disk only

METADATADefined by the user as a method to document valuable information about the test. Enables customized searching for input data and results on the BK Connect local database

DATA SHARING Via external BK Common file enables one file to contain all results from a common source, including their metadata

18

Page 19: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Specifications – BK Connect Data Viewer (advanced) Type 8400‐AType 8400‐A adds the following functionality and specifications to BK Connect Data Viewer Type 8400:• Data Table Viewer sub‐task• Result Matrix Viewer sub‐task• Scratchpad Calculator sub‐task • Included PULSE Data Manager Type 7767‐A (PDM) licence – database solution for legacy PULSE LabShop applications

Data Table ViewerThe Data Table Viewer enables review and display of project data:• Data table with user‐configurable columns. Can contain a wide range of data descriptors, including user‐defined metadata

• Advanced filtering and sorting capabilities using a combination of columns, providing a powerful way to focus on any data of interest

• Automatic data presentation in graphical displays. Auto‐filled based on data selection in the table

• Controls in header bar enables table selections to be automatically incremented for quick and easy scanning through the entire data set

• Automatic report generation based on the data selection in the table

Result Matrix ViewerThe Result Matrix Viewer provides a structured overview of results from a large number of tests, making selection and comparison very easy:• Result layout as a matrix of signals versus analyses• Smart results grouping – each individual cell in the matrix represents a group of similar results for which comparison is valid 

• Automatic result data presentation – selecting a cell presents the results, either in a table view for scalars, or graphical display for function data

• Automatic report generation – reports can be generated in either Microsoft® Word or PowerPoint®, either from blank documents, or from templates prepared in advance. Template creation is controlled directly from the Data Viewer and is both flexible and easy to perform

Scratchpad Calculator

FUNCTION MATH Operates on a function selection using another single selected function• Add• Subtract• Multiply• Divide• Addition in dB• Subtraction in dB

FUNCTION OPERATORS Operates on a function selection• Natural logarithm: Ln• Inverse Ln: e to the power of the function amplitude• Logarithm to the base 10: Log10• Inverse Log10: 10 to the power of the function amplitude• Reciprocal• Square Root• Square• Raise to power, x^y• Absolute Value• To dB: Convert amplitude of a function to dB values with a user‐defined reference

• To Real: Result is a function containing real values from selected complex function

• To Imaginary: Result is a function containing imaginary values from selected complex function

• To Magnitude: Result is a function containing magnitude values from selected complex function

• To Phase: Result is a function containing phase values from selected complex function

• Conjugate: Result is complex conjugate of selected complex function

SCALING Operates on a function selection• Scale by Real: multiply selected functions by real‐valued scalar• Scale by Complex: multiply selected functions by complex‐valued scalar

• Scale by Averaging Time: Multiply selected functions by the averaging time, for example, to get sound exposure levels (SEL, ASEL, …)

STATISTICS Operates on a function selection, single value output• Mean Value• Standard Deviation• Variance• Skewness• Kurtosis• Max Value• Min Value• RMS Value• Crest Factor• Sum Value

FUNCTION STATISTICS Operates on a function selection, single function output• Mean• Standard Deviation• Mean minus Standard Deviation• Mean plus Standard Deviation• Min• Max• Sum

FREQUENCY WEIGHTING Operates on a function selection• Linear Weighting: Remove weighting from spectrum• A‐Weighting: Apply A‐weighting (removing existing weighting first)• B‐Weighting: Apply B‐weighting (removing existing weighting first)• C‐Weighting: Apply C‐weighting (removing existing weighting first)• D‐Weighting: Apply D‐weighting (removing existing weighting first)• Single Integration• Double Integration• Single Differentiation• Double Differentiation

INTERPOLATION Operates on a function selection• Linear vs Frequency: Interpolate frequency values according to min, max and interval

• Linear vs RPM: Interpolate rpm values according to min, max and interval

• Linear vs Time: Interpolate time values according to min, max and interval

19

Page 20: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Specifications – BK Connect File Importer OptionsTypes 8400‐B, C, D, E and F are options that enable expanded data import and export functionality to all BK Connect applications

Native File Importers Type 8400‐BAdds following import and export functionality to any application:• File formats used natively in Brüel & Kjær applications: – .pti (PULSE time data) – .dat (time data, must also have the ancillary *.rec file) – import only

– .txt (PULSE ASCII time and function data) – import only– .ati (Test for I‐deas time data)– .afu (Test for I‐deas function data) – import only– .unv and .uff (time and function data) – .wav (time data) 

• Import from LabShop and Import from PDM sub‐tasks: Direct import from LabShop Measurement and Function Organisers

• PULSE ASCII files can be exported from both PULSE LabShop and PULSE Data Manager (PDM) to BK Connect

• Export to Excel• Files linked either to a project in their original format (at their original location) and worked on without converting to native BK Connect format, or copied and converted to BK Connect format, bringing them under control of the BK Connect database

• Included PULSE LabShop Viewer Type 7709 licence for PULSE LabShop software owners with a valid M1 agreement

External File Importers Type 8400‐CAdds following import and export functionality to any application:• Third‐party file formats– .atfx (ASAM‐ODS time data)– .DATX (DSPCon time data)– .hdf and .dat (Head Acoustics time data)– .rpc (MTS RPC III time data)– .sie (HBM Somat time data) – import only– .sdf (HP analyzers standard data format for time and function data)

• Files linked either to a project in their original format (at their original location) and worked on without converting to native BK Connect format, or copied and converted to BK Connect format, bringing them under control of the BK Connect database

Nastran Finite Element Interface Type 8400‐DAdds following importing functionality to any application:• Nastran finite element models (MSC, NEi and NX)

Ansys Finite Element Interface Type 8400‐EAdds following importing functionality to any application:• Ansys finite element models

Abaqus Finite Element Interface Type 8400‐FAdds following importing functionality to any application:• Abaqus finite element models

Specifications – BK Connect Hardware Setup Type 8401

Features• Support for up to two data acquisition modules• Transducer Manager for transducer set‐up• Hardware Browser for channel set‐up• Transducer calibration/verification• Real‐time Monitor including a monitor recorder

Hardware ConfigurationThe software automatically detects the front‐end hardware and configures the system. If IEEE 1451.4 capable transducers (with standardized TEDS) are being used, these are detected and attached automatically to the correct input channels

HARDWARE BROWSERThe Hardware Browser combines an interactive display of the front‐end hardware, called the Hardware Matrix, and a channel list called the HW Setup Table. These two components, working together, provide a highly efficient way to work with any size systemHeader bar buttons in the Hardware Browser allow for: • Resetting of channel status• Reconnecting the front end• Display of either the HW Setup Table, the LAN‐XI home page, or an overall level meter for all channels

HARDWARE MATRIXThe Hardware Matrix has the following functionality:• Signal levels indicated using coloured rings• Channel overload status, using different symbols for different types of overload

• Transducer status, using symbols to identify each transducer type• Calibration/verification status when used in the Transducer Verification task

• Drop destination for transducers dragged from the Transducer Manager• Channel selector for the HW Setup Table and overall level meter• Automatic indication of TEDS transducers

Available Matrix Display Styles: • Physical: A visually representative display of the physical front‐end hardware

• Logical: Channels shown as coloured rings in the same configuration as the physical hardware

HW SETUP TABLE The HW Setup Table contains all information about the front‐end hardware and any transducers connected to it. The number of rows displayed in the table depends on the channel selection made in the Hardware Matrix, the default being all channels. The size of the table updates dynamically according to which channels are selected in the Hardware Matrix, making it very easy to focus on subsets of channels when neededEditing the Table: • Manual editing of channel information• Update from an external XML or UFF 1808 (Channel Table) file or from Microsoft® Excel®

• Save HW Setup Table contents to an external XML or UFF 1808 (Channel Table) file for later use

• Create different (favourite) views to tailor which columns should be shown

TRANSDUCER MANAGERThe Transducer Manager works with a Microsoft® Access® database (as used by PULSE LabShop) to manage transducer specifications and calibration information. A full set of Brüel & Kjær transducer types, with nominal sensitivities, is provided with all BK Connect installations, but more can be added using the Transducer Manager. Each transducer type can have a number of devices of that type, each with its own unique calibration historyAdding Transducers: Individual devices, or groups of devices, can be dragged and dropped onto the Hardware Matrix to add transducers to the configuration and/or add calibration/sensitivity information: • Drag a transducer type to many (or all) channels. The HW Setup Table applies the nominal sensitivity for that type to the selected channel(s)

• (Typical) Drag specific devices to individual channels where they are known to be physically connected

20

Page 21: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Real‐time Monitor

MONITORSChannel monitor (time or FFT), channel level meter, channel level history, elapsed time, rpm profile, tachometerFFT Monitor: Monitors 2D spectra or 3D spectrograms for all active channels or selected channels. Grouped automatically based on the physical quantityLevels Monitor: Monitors the overall levels displayed in voltage or physical quantity for all active or selected channels. The data can be monitored as instantaneous level or max. hold, using slow, fast or impulsive time weightingTime Monitor: Monitors the complete raw time history for the entire length of the recording, while overlaying overload and marker locations

LAYOUT VIEWS• Square Grid: Completely dynamic. Signals form a best‐fit grid in the available screen space using coloured rings to display signal amplitude

• Bar Grid: Completely dynamic. Signals form a best‐fit grid in the available screen space using bars to display signal amplitude

Note that the grid displays can be sorted according to Signal Name, Maximum Level, Minimum Level and Level Range

Transducer VerificationTransducer Verification (under Setup) can be used either to verify that transducers are functioning correctly, or to make a new calibrationA transducer calibrator is used to apply the necessary excitation for either verification or calibration. Multiple calibrators can be used simultaneouslyThe software automatically detects the calibrator signal and performs the verification/calibration, with coloured status indicators in the Hardware Matrix and HW Setup Table showing In Progress, Failed or Passed. At the end of the procedure, the Transducer Manager is updated along with the HW Setup Table and calibration information is added to the device’s calibration history

Specifications – BK Connect Hardware Setup Types 8401‐A and 8401‐V

Hardware Setup (advanced) Type 8401‐AAdds following features to Type 8401:• Support for more than two data acquisition modules• System validation tasks (analogue diagnostics)• Advanced system verification task, Accelerometer Mounting Check, that works with select Bruel and Kjaer accelerometers utilizing unique Brüel & Kjær measurement chain technology

Virtual Hardware Setup Type 8401‐V• Set up of a virtual hardware configuration from a file using same tools as in Type 8401. No physical hardware is required

Specifications – BK Connect Time Data Recorder Type 8402BK Connect Data Viewer Type 8400 is the prerequisite licence. All other applications add functionality to the prerequisite licence

Features• Signal and speed signal triggers to start and stop recordings• Manual triggering of recordings• Coupled with the Hardware Matrix and real‐time monitors • Markers during a recording are displayed in real time in the monitors• Multiple recording modes: single, multi and circular• Included licences for PULSE LabShop software owners with a valid M1 agreement: PULSE LabShop Time Type 7789, PULSE LabShop Time Capture Type 7705 and PULSE LabShop Time Data Recorder Type 7708

Recording

BASEBAND FREQUENCY SPAN50 Hz – 204.8 kHz in 2n (1, 2, 4, 8, …) sequence 

FREQUENCY SPANMax. 204.8 kHz per channel (hardware module dependent)

CHANNEL × BANDWIDTHThe maximum rate is dependent on the acquisition hardware and PC configuration but a total rate of 4 MHz (40 Mbyte/s) can be expected from a typical system and rates exceeding 15 MHz (150 Mbyte/s) are obtainable on specially configured PCs

RECORDING MODES Single: Maximum recording length is defined by the size of the recording diskMulti and Circular: Maximum recording length is defined by the size of the recording disk:• Maximum number of sub‐recordings is limited to 32767• Maximum length of a sub‐recording is 65.4 ks 18 h• Maximum recording length is more than 1 year (Max. sub‐recordings × Max. length of sub‐recording) 

TRIGGERINGStart and Stop of a recording can be controlled manually or using a trigger, via a time delay, a predefined signal level, or at a specified RPM

EVENT MARKERS All markers in a single recording have the same name. The number automatically increments with each pair of markers added, so that the pair define the start and end points.Markers are used to define regions during post‐processing

METADATA Metadata values entered are saved with any subsequent recordings made during the current session (or until changed)

EXPORT FILE FORMATS .bkc (BK Connect native format)

21

Page 22: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

Specifications – BK Connect Time Data Recorder (advanced) Type 8402‐AType 8402‐A adds the following functionality and specifications to BK Connect Time Data Recorder Type 8402:• Time Data Review analysis sub‐task which allows: – Listening to recordings in the project– Trimming of original recordings– Editing markers added during a recording

REQUIREMENTS• PC should be equipped with a sound card that is compatible with Windows® in order to play back signals

• A PC optimized for CPU and hard disk intensive operations is recommended

Specifications – BK Connect Data Processing Type 8403BK Connect Data Viewer Type 8400 is the prerequisite licence. All other applications add functionality to the prerequisite licence

Features• Trigger setting for background recording in the Standard Measurements task

• Analysis of time data: FFT, FFT vs time, overall, overall vs time, and rpm vs time, including pre‐processing elements (weighting, filtering integration, etc.)

• Immediate display and store of analysis results• Automated processing using the Standard Processing task• Standard FFT‐based measurements • Automated reporting• Included PULSE LabShop FFT & CPB Analysis Type 7700 licence (measurement and analysis with unlimited channel count) for PULSE LabShop software owners with a valid M1 agreement

MeasurementOnly available with BK Connect Hardware Setup Type 8401 licence

MEASUREMENT CONTROLAveraging: Averaging can be performed either in the frequency or time domains. Averaging types available for the measured signals are:• Linear (fixed number of blocks)• Linear All (full time range)• Exponential• Maximum hold

ANALYZERSFFT and Overall Level analysis 

FFT ANALYSISThe following specifications also apply to all FFT process chain elements: FFT Signal, FFT System, FFT Signal vs Time and FFT System vs Time Frequency Range: • Baseband and Zoom: 50 – 102400 lines• Frequency Span: 1 Hz – 204.8 kHz in 1, 2, 5 … or 2n (1, 2, 4, 8 …) sequence (depending on hardware)

Signal Type: Random; Periodic; TransientProperties are automatically set up to a logical default; e.g., when transient type is selected, Signal Trigger is selected as the triggering modeTriggering Modes: • Free run• Signal Trigger: Trigger attributes include level, hysteresis, slope, hold‐off, delay and divider

Time Weighting: The following are available:• Exponential• Uniform• Transient• Hanning• Flat‐top• Kaiser‐BesselOverlap: User selectable values of 0%, 50%, 66.67%, and 75%, user editable from 0% to 99%

Output: • FFT Signal: Autospectrum, Cross‐spectrum, Phase‐assigned Spectrum, Time, Weighted Time

• FFT System: Autospectrum, H1, H2, H3 and Hv FRFs, Coherence, Principal Component, Cross‐spectrum, Phase‐assigned Spectrum, Signal‐to‐Noise, Coherent Power Spectrum, Non‐coherent Power Spectrum, Time, Weighted Time. MIMO computation for H1, Hv, Coherence and Principal Component

• FFT Signal vs Time and FFT Signal vs RPM: Autospectrum Phase‐assigned Spectrum, Time, Weighted Time

• FFT System vs Time: Autospectrum, H1, H2, H3 and Hv FRFs, Coherence, Principal Component, Cross‐spectrum, Phase‐assigned Spectrum, Signal‐to‐Noise, Coherent Power Spectrum, Non‐coherent Power Spectrum, Time, Weighted Time. MIMO computation for H1, Hv, Coherence and Principal Component

• Correlation: Auto‐correlation, Cross‐correlation, Time

OVERALL ANALYSISAlso applies to all Overall Level analyzer process chain elements: Overall, Overall vs Time, and Overall vs RPM (with Type 8405‐E).Meets the requirements for a class 1 instrument in IEC 61672–1, ANSI S1.43‐1997 Type 1, ANSI S1.4‐1983 Type 1, IEC 804‐1985 and IEC 651Averaging: Exponential, Impulse, Linear (Leq), Linear All, True Peak, True Peak AllTrigger Method: Free run; Fixed time interval An auxiliary signal may be used as a trigger signalFrequency Span: 1 Hz – 204.8 kHz in 1, 2, 5 … or 2n (1, 2, 4, 8 …)sequenceAcoustic Weighting: As signals, A, B, C, D, G

Data ProcessingAutomated processing that requires a project template (created by a Type 8404/8404‐A specialist) with a predefined process chain

PROCESSING TYPES Four basic types of process chain elements – Pre‐analysis, Analysis, Post‐analysis and GeneralPre‐analysis Elements: • Acoustic Weighting: A‐, B‐, C‐, D and G‐weighting. Meeting the requirements of IEC 61672–1, ANSI S1.42–2001, and ISO 7196:1995

• Human Vibration Weighting: Linear, Wb, Wc, Wd, We, Wf, Wh, Wj, Wk, Wm (ISO 2631)

• Integration/Differentiation: • Filters: FIR low pass, high pass, band pass and band stop. Filter lengths: 512, 1024, 2048, 4096, 16384 and 32768 samples

• HATS Equalizer: Apply known sound field correction filters for Head and Torso Simulators and binaural recording headsets

• Resample: To range of 20 user‐selectable freq., 512 Hz to 524.288 kHz

• Gate: Open and close data flow based on signal triggers, different signals can be used for opening and closing

Analysis Elements: • FFT Signal • FFT System• Overall Level• Correlation

22

Page 23: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

• FFT Signal vs time• FFT System vs time• Overall Level vs time• RPM vs timePost‐analysis Elements: • CPB Synthesis (1/n‐octave, n = all integers from 1 to 24)• Playback: Playback of selected signals with gain, pan and mute controls

• Frequency Band Extraction• Peak Finder: Peak/valley extraction from FFT spectra

General Elements: • Individual Display: Display strategy setup for creation of multiple display pages in the Display Manager

• Fast Display: Fast displays, 2D and Colour Contour, which update in real time during processing. Normal processing speed is much faster than real time; to force 1:1 real‐time processing use a Playback element

• Result Matrix: Review results before storing them using same functionality as Data Viewer’s Result Matrix Viewer

• Store: Setup of folder structure and names for results output from a standard process or batch process

• Collect: Setup of folder structure and names for results output from a collection batch process

Specifications – BK Connect Data Processing Specialist Type 8404BK Connect Data Viewer Type 8400 is the prerequisite licence. All other applications add functionality to the prerequisite licence

Features• Analysis of time data• Analysis set‐up capability• Manual data processing (process chain creation)• Time Editor for time data editing before analysis with interactive filters and spectrogram

• Function data processing• Template creation for use with Data Processing Type 8403 licences• Immediate display and store of analysis results• Automated reporting• Included PULSE LabShop FFT & CPB Analysis Type 7700 licence (measurement and analysis with unlimited channel count) and PULSE LabShop Time Capture Type 7705 licence for PULSE LabShop software owners with a valid M1 agreement

Time EditorDisplay, audio playback and pre‐processing of time data in preparation for analysis:• Automatic calculation of rpm profile from a tachometer pulse train• Fast navigation by scrolling through channels, panning and zooming in time axis

• Region selection by group of channels and time range• Saving regions to project• Appending of regions to other regions (concatenation)• Manual grouping of regions – for batch processing• Automated generation of regions from multiple files having similar channel configurations – in preparation for batch processing

• Fast spectrogram display – synchronized with time data display & playback

• Interactive order slice and frequency spectrum display synchronized with spectrogram cross‐hair cursor

Data ProcessingAll functionality is contained in the process chain, which consists of graphical elements connected together to form an analysis process 

ANALYZERSFFT and Overall Level analysis 

INPUT An input area is provided into which data is dragged‐and‐dropped Time Data: Using Time Data Processing, drag either from the Time Editor or Project Browser (if no editing required)Function Data: Using Function Data Processing, drag directly from the Project BrowserAuxiliary Data: Using Time Data Processing, drag either from the Time Editor or Project Browser. Overall analysis is recommended

STORAGE AND EXPORT A process chain can be stored in the project for later use. It can also be exported to an external file for transfer to other computers

AUTOMATION• Auto Import: Definition of folder on disk to which the system checks for data files for automated import and processing

• Signal Filter: Filter by data name or physical quantity for processing• Batch Job: Automated batch processing 

PROCESSING TYPES Four basic types of process chain elements – Pre‐analysis, Analysis, Post‐analysis and GeneralPre‐analysis Elements: • Acoustic Weighting: A‐, B‐, C‐, D and G‐weighting. Meeting the requirements of IEC 61672‐1, ANSI S1.42‐2001, and ISO 7196:1995

• Human Vibration Weighting: Linear, Wb, Wc, Wd, We, Wf, Wh, Wj, Wk, Wm (ISO 2631)

• Integration/Differentiation: • Filters: FIR low pass, high pass, band pass and band stop. Filter lengths: 512, 1024, 2048, 4096, 16384 and 32768 samples

• HATS Equalizer: Apply known sound field correction filters for Head and Torso Simulators and binaural recording headsets

• Resample: To range of 20 user‐selectable freq., 512 Hz to 524.288 kHz

• Gate: Open and close data flow based on signal triggers, different signals can be used for opening and closing

Analysis Elements: • FFT Signal • FFT System• Overall Level• Correlation• FFT Signal vs time• FFT System vs time• Overall Level vs time• RPM vs timePost‐analysis Elements: • CPB Synthesis (1/n‐octave, n = all integers from 1 to 24)• Playback: Playback of selected signals with gain, pan and mute controls

• Frequency Band Extraction• Peak Finder: Peak/valley extraction from FFT spectraGeneral Elements: • Individual Display: Display strategy setup for creation of multiple display pages in the Display Manager

• Fast Display: Fast displays, 2D and Colour Contour, which update in real time during processing. Normal processing speed is much faster than real time; to force 1:1 real‐time processing use a Playback element

• Result Matrix: Review results before storing them using same functionality as Data Viewer’s Result Matrix Viewer

• Store: Setup of folder structure and names for results output from a standard process or batch process

23

Page 24: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

• Collect: Setup of folder structure and names for results output from a collection batch process

FFT ANALYSISThe following specifications apply to all FFT process chain elements: FFT Signal, FFT System, FFT Signal vs Time and FFT System vs Time Frequency Range: • Baseband and Zoom: 50 – 102400 lines• Frequency Span: 1 Hz – 204.8 kHz in 1, 2, 5 … or 2n (1, 2, 4, 8 …) sequence (depending on hardware)

Signal Type: Random; Periodic; TransientProperties are automatically set up to a logical default; e.g., when transient type is selected, Signal Trigger is selected as the triggering modeTriggering Modes: • Free run• Signal Trigger: Trigger attributes include level, hysteresis, slope, hold‐off, delay and divider

Time Weighting: The following are available:• Exponential• Uniform• Transient• Hanning• Flat‐top• Kaiser‐BesselOverlap: User selectable values of 0%, 50%, 66.67%, and 75%, user editable from 0% to 99%

Output: • FFT Signal: Autospectrum, Cross‐spectrum, Phase‐assigned Spectrum, Time, Weighted Time

• FFT System: Autospectrum, H1, H2, H3 and Hv FRFs, Coherence, Principal Component, Cross‐spectrum, Phase‐assigned Spectrum, Signal‐to‐Noise, Coherent Power Spectrum, Non‐coherent Power Spectrum, Time, Weighted Time. MIMO computation for H1, Hv, Coherence and Principal Component

• FFT Signal vs Time and FFT Signal vs RPM: Autospectrum Phase‐assigned Spectrum, Time, Weighted Time

• FFT System vs Time: Autospectrum, H1, H2, H3 and Hv FRFs, Coherence, Principal Component, Cross‐spectrum, Phase‐assigned Spectrum, Signal‐to‐Noise, Coherent Power Spectrum, Non‐coherent Power Spectrum, Time, Weighted Time. MIMO computation for H1, Hv, Coherence and Principal Component

• Correlation: Auto‐correlation, Cross‐correlation, Time

OVERALL ANALYSISApplies to all Overall Level analyzer process chain elements: Overall, Overall vs Time, and Overall vs RPM (with Type 8405‐E).Meets the requirements for a class 1 instrument in IEC 61672‐1, ANSI S1.43‐1997 Type 1, ANSI S1.4‐1983 Type 1, IEC 804‐1985 and IEC 651Averaging: Exponential, Impulse, Linear (Leq), Linear All, True Peak, True Peak AllTrigger Method: Free run; Fixed time interval An auxiliary signal may be used as a trigger signalFrequency Span: 1 Hz – 204.8 kHz in 1, 2, 5 … or 2n (1, 2, 4, 8 …)sequenceAcoustic Weighting: As signals, A, B, C, D, G

Specifications – BK Connect Data Processing Specialist (advanced) Type 8404‐AType 8404‐A adds the following Type 8403 functionality and specifications to BK Connect Data Processor Type 8404: • Automated processing with the Standard Processing task• Standard FFT‐based measurements • Trigger setting for background recording in the Standard Measurements task

Specifications – BK Connect Data Processing Options Type 8405‐B, 8405‐C, 8405‐D, 8405‐E, 8405‐F and 8405‐GTypes 8405‐B, C, D, E, F and G are options that enable expanded processing functionality to all BK Connect Data Processing applications

Advanced Frequency Analysis Option Type 8405‐BAdds following analysis functionality to Types 8403 and 8404/8404‐A:

DATA PROCESSINGAnalysis Elements: • Demodulator – Amplitude or Phase Demodulation as a pre‐analysis element

• Envelope – Combination of a demodulator and a classic FFT with user‐definable analysis bandwidth (see Type 8404 for FFT specifications) and a tuning frequency 

• Time correlation• Infinite Impulse Response (IIR) Filter – Butterworth and Chebyshev with a user definable filter order

INCLUDED LICENCESPULSE LabShop Envelope Analysis Type 7773 and PULSE LabShop Multiple‐input Multiple‐output Analysis Type 7764 (MIMO) licences for PULSE LabShop software owners with a valid M1 agreement

CPB Option Type 8405‐CAdds following analysis functionality to Types 8403 and 8404/8404‐A:

DATA PROCESSINGAnalysis Elements: • CPB Standardized• CPB vs Time• CPB vs RPM (also requires Type 8405‐E)The CPB elements operate with 1/n‐octave bands, where n = 1, 3, 6, 12and 24. Multiple CPB analyzers can be used simultaneously

MEASUREMENT1/1‐octave Filters: 14‐pole filters with centre frequencies given by 103n/10, where –3  n17 (21 filters).Filters with centre frequencies from 250 mHz to 125 kHz that meet the requirements of:• IEC 61260‐1 Class 1• IEC 1260‐1995 Class 1• IEC 225‐1966• ANSI S1.11‐2004 Class 1• ANSI S1.11‐1986 Order 7 Type 1‐D, optional range• ANSI S1.11‐1966 Class 1 Type E• DIN 45651 (1964‐01)

24

Page 25: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

1/3‐octave Filters: 6‐pole filters with centre frequencies given by 10n/10, where –10 n52 (63 filters).Filters with centre frequencies from 266 mHz to 160 kHz that meet the requirements of:• IEC 61260‐1 Class 1• IEC 1260‐1995 Class 1• IEC 225‐1966• ANSI S1.11‐2004 Class 1• ANSI S1.11‐1986 Order 7 Type 1‐D• ANSI S1.11‐1966 Class 1 Type E• DIN 45651 (1964‐01)1/6‐octave Filters: 6‐pole filters with centre frequencies given by10(n + 0.5)/20, where –21 n104 (126 filters).Filters with centre frequencies from 270 mHz to 168 kHz that meet the requirements of:• IEC 61260‐1 Class 1• IEC 1260‐1995 Class 1• ANSI S1.11‐2004 Class 11/12‐octave Filters: 6‐pole filters with centre frequencies given by10(n + 0.5)/40, where –42 n209 (252 filters).Filters with centre frequencies from 345 mHz to 173 kHz that meet the requirements of:• IEC 61260‐1 Class 1• IEC 1260‐1995 Class 1• ANSI S1.11‐2004 Class 11/24‐octave Filters: 6‐pole filters with centre frequencies given by 10(n + 0.5)/80, where –84 n419 (504 filters).Filters with centre frequencies from 208 mHz to 175 kHz that meet the requirements of:• IEC 61260‐1 Class 1• IEC 1260‐1995 Class 1• ANSI S1.11‐2004 Type 1CPB Spectrum Averaging: • Linear (fixed time range)• Linear All (full time range)• ExponentialMax./Min. Spectrum Hold: Max./Min. Hold of spectrum for exponential averaging modeAcoustic Weighting: Perform acoustic weighting on sound pressure signals before CPB analyses. Select between A, B, C, D and G‐weightingOverall Bands: Process overall bands in parallel with the CPB spectraThe overall bands can be acoustic weighted

INCLUDED LICENCESPULSE LabShop CPB Analysis Type 7771 licence (with unlimited channel count) for PULSE LabShop software owners with a valid M1 agreement

Calculations Option Type 8405‐DAdds following analysis functionality to Types 8403 and 8404/8404‐A:

DATA PROCESSINGAnalysis Elements: • Batch Statistics• Calculation elements: Statistics, Function Statistics, Function Operators, Scaling, Frequency Weighting (frequency domain), Complex Math (toReal, toImaginary, toMagnitude, toPhase, toConjugate)

Order Analysis Option Type 8405‐EAdds following analysis functionality to Types 8403 and 8404/8404‐A:

TIME EDITOR• Synthesis of tachometer pulse train from a given rpm profile • Tacho repair: Profile smoothing and drop‐out/spurious pulse correction

DATA PROCESSINGAnalysis Elements: • FFT Signal vs RPM and FFT System vs RPM• Order Extraction: Order slices, relative or absolute bandwidth, from FFT vs RPM 3D spectra. Optional smoothing for cleaner order slices 

• CPB vs RPM (also requires Type 8405‐C)• Overall vs RPMOutput: • FFT Signal vs RPM: Auto‐spectrum, Phase‐assigned Spectrum, Time, Weighted Time 

• FFT System vs RPM: Auto‐spectrum, H1, H2, H3 and Hv FRFs, Coherence, Principal Component, Cross‐spectrum, Phase‐assigned Spectrum, Signal‐to‐Noise, Coherent Power Spectrum, Non‐coherent Power, Spectrum, Time, Weighted Time. MIMO computation for H1, Hv, Coherence and Principal Component

GRAPHICAL ORDER EXTRACTORAn additional analysis task for quickly visualizing and storing sets of order slices one signal at a time. Displays update automatically when moving order cursors and selecting different data sets• Order slice extraction• Overall rms level computed from input spectra • Frequency band rms level extraction, band defined by delta cursor• Optional selection of modulation frequency• Store to project Input: RPM‐tagged 3D spectra 

AUTO‐TRACKERAn additional task for extraction of rpm profile from FFT vs Time results. When combined with tachometer pulse train synthesis, rpm‐related analysis of data without a tachometer measurement is enabled

INCLUDED LICENCESPULSE LabShop Order Analysis Type 7702 licence (with unlimited channel count) and PULSE LabShop Sound Quality Order Analysis BZ‐5277 licence for PULSE LabShop software owners with a valid M1 agreement

Order Tracking Option Type 8405‐FAdds following analysis functionality to Types 8403 and 8404/8404‐A:

TIME EDITOR• Synthesis of tachometer pulse train from a given rpm profile • Tacho repair: Profile smoothing and drop‐out/spurious pulse correction

DATA PROCESSINGAnalysis Elements: • Order spectrum – similar output options as ordinary FFT analysis except with evenly spaced order axis instead of frequency

• Order spectrum vs time• Order spectrum vs RPM• Order extraction (order slices extracted from order spectra)Output: Order spectrum• Auto‐spectrum• Phase‐assigned Spectrum• Time• Weighted Time 

GRAPHICAL ORDER EXTRACTORAn additional analysis task for quickly visualising and storing sets of order slices one signal at a time. Displays update automatically when moving order cursors and selecting different data sets• Order slice extraction• Overall rms level computed from input spectra • Frequency band rms level extraction, band defined by delta cursor• Optional selection of modulation frequency• Store to project Input: RPM‐tagged 3D spectra 

AUTO‐TRACKERAn additional task for extraction of rpm profile from FFT vs Time results. When combined with tachometer pulse train synthesis, rpm‐related analysis of data without a tachometer measurement is enabled

25

Page 26: Product Data: BK Connect Core Suite of Applications: Data Viewer …€¦ · the native BK Connect (*.bkc) format, which preserves the project, test and set‐up metadata. When used

BP-0005---sÎ

BP0005–12

2018‐03

© Brüel&Kjæ

r. All righ

ts reserved.

INCLUDED LICENCESPULSE LabShop Order Analysis Type 7702 licence (with unlimited channel count) and PULSE LabShop Sound Quality Order Analysis BZ‐5277 licence for PULSE LabShop software owners with a valid M1 agreement

Sound Quality Metrics Option Type 8405‐GAdds following analysis functionality to Types 8403 and 8404/8404‐A:

DATA PROCESSINGAnalysis Elements: • SQ Metrics and SQ Metrics vs Time

SOUND QUALITY METRICS• Stationary Loudness – ISO 532B, Moore‐Glasberg model (ISO 532–1 proposal) based on FFT or CPB

• Time‐varying Loudness – DIN 45631 and Zwicker (1989), • DIN 45631/A1 (2010)

• Statistical Loudness with user‐definable percentile• Loudness Level – ISO 532B• Binaural loudness – Robinson and Whittle (1960), Moore‐Glasberg model and mean loudness between the two ears

• Sharpness – with methods Aures, DIN 45692 (2009), Zwicker, Bismarck

• Articulation Index (AI) – Beranek• Roughness – Zwicker et al.• Fluctuation Strength – Zwicker et al.• Tonality – Terhardt • Tone‐to‐Noise Ratio – ANSI S1.13 (2005)• Prominence Ratio – ANSI S1.13 (2005)

INCLUDED LICENCESPULSE LabShop Sound Quality Type 7698 and PULSE LabShop Sound Quality Zwicker Loudness BZ‐5265 licences for PULSE LabShop software owners with a valid M1 agreement

Ordering Information*

Software Modules

BASIC APPLICATION AND IMPORT OPTION MODULESType 8400‐X BK Connect Data ViewerType 8400‐A‐X BK Connect Data Viewer (advanced)Type 8400‐B‐X BK Connect Native File ImportersType 8400‐C‐X BK Connect External File ImportersType 8400‐D‐X BK Connect Nastran Interface Type 8400‐E‐X BK Connect Ansys Interface Type 8400‐F‐X BK Connect Abaqus Interface 

DATA ACQUISITION APPLICATION MODULESType 8401‐X BK Connect Hardware SetupType 8401‐A‐X BK Connect Hardware Setup (advanced)Type 8401‐V‐X BK Connect Virtual Hardware Setup

DATA RECORDING APPLICATION MODULESType 8402‐X BK Connect Time Data RecorderType 8402‐A‐X BK Connect Time Data Recorder (advanced)

DATA PROCESSING APPLICATION AND OPTION MODULESType 8403‐X BK Connect Data ProcessingType 8404‐X BK Connect Data Processing SpecialistType 8404‐A‐X BK Connect Data Processing Specialist (advanced)Type 8405‐B‐ X BK Connect Advanced Frequency Analysis OptionType 8405‐C‐X BK Connect CPB OptionType 8405‐D‐X BK Connect Calculations OptionType 8405‐E‐X BK Connect Order Analysis OptionType 8405‐F‐X BK Connect Order Tracking OptionType 8405‐G‐X BK Connect Sound Quality Metrics Option

Software Maintenance and Support Agreements†

M1‐8400‐X Agreement for Type 8400M1‐8400‐A‐X Agreement for Type 8400‐AM1‐8400‐B‐X Agreement for Type 8400‐BM1‐8400‐C‐X Agreement for Type 8400‐CM1‐8400‐D‐X Agreement for Type 8400‐DM1‐8400‐E‐X Agreement for Type 8400‐EM1‐8400‐F‐X Agreement for Type 8400‐FM1‐8401‐X Agreement for Type 8401M1‐8401‐A‐X Agreement for Type 8401‐AM1‐8401‐V‐X Agreement for Type 8401‐VM1‐8402‐X Agreement for Type 8402

M1‐8402‐A‐X Agreement for Type 8402‐AM1‐8403‐X Agreement for Type 8403M1‐8404‐X Agreement for Type 8404M1‐8404‐A‐X Agreement for Type 8404‐AM1‐8405‐B‐X Agreement for Type 8405‐BM1‐8405‐C‐X Agreement for Type 8405‐CM1‐8405‐D‐X Agreement for Type 8405‐DM1‐8405‐E‐X Agreement for Type 8405‐EM1‐8405‐F‐X Agreement for Type 8405‐FM1‐8405‐G‐X Agreement for Type 8405‐G

* “X” indicates the license model, either N: Node locked or F: Floating† Agreement expiration date to be agreed at time of contract

Brüel & Kjær Sound & Vibration Measurement A/SDK‐2850 Nærum ∙ Denmark ∙ Telephone: +45 77 41 20 00 ∙ Fax: +45 45 80 14 05www.bksv.com ∙ [email protected] representatives and service organizations worldwideAlthough reasonable care has been taken to ensure the information in this document is accurate, nothingherein can be construed to imply representation or warranty as to its accuracy, currency or completeness, noris  it  intended  to  form  the basis  of  any  contract.  Content  is  subject  to  change without notice –  contactBrüel & Kjær for the latest version of this document.

Brüel & Kjær and all other trademarks, service marks, trade names, logos and product names are the property of Brüel & Kjær or a third‐party company.

Ë