8
PRODUCT DATA SHEET Sika® AnchorFix-2 SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM PRODUCT DESCRIPTION Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two com- ponent adhesive anchor system for threaded bars in un- cracked concrete. USES Sika® AnchorFix-2 may only be used by experienced pro- fessionals. As a fast curing anchoring adhesive for all grades of: Rebars / reinforcing steel Threaded rods Bolts and special fastening systems In the following substrates: Concrete Solid masonry Steel Hard natural stone * Solid rock * * These substrates may vary greatly, in particular with regard to strength, com- position and porosity. Therefore, for each application the suitability of Sika® An- chorFix-2 Adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discoloration. CHARACTERISTICS / ADVANTAGES Fast curing Standard guns can be used High load capacity Drinking Water certified Non-sag, even overhead Styrene-free epoxy acrylate Low wastage Fixing close to free edges. Versatile range of embedment depths. Anchoring without expansion forces. APPROVALS / STANDARDS EESR to AC308 by ICC-ES PENDING. ESR to AC308 by IAPMO-UES. Certified to ANSI / NSF - 61 by UL. PRODUCT INFORMATION Packaging 10 fl.oz. (299 ml) cartridge Shelf Life 12 months from date of production All Sika® AnchorFix-2 cartridges have the expiry date printed on the label. Storage Conditions Cartridges should be stored in their original packaging, the correct way up, in cool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight. Product Data Sheet Sika® AnchorFix-2 June 2018, Version 01.01 020205010020000001 1 / 8

Upload: ngonga

Post on 02-Sep-2018

226 views

Category:

Documents


2 download

TRANSCRIPT

PRODUCT DATA SHEETSika® AnchorFix-2SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM

PRODUCT DESCRIPTIONSika® AnchorFix-2 adhesive anchor system issolvent/styrene free, epoxy acrylate based, and has beenspecifically formulated as a high performance, two com-ponent adhesive anchor system for threaded bars in un-cracked concrete.

USESSika® AnchorFix-2 may only be used by experienced pro-fessionals.As a fast curing anchoring adhesive for all grades of:

Rebars / reinforcing steel▪Threaded rods▪Bolts and special fastening systems▪

In the following substrates:Concrete▪Solid masonry▪Steel▪Hard natural stone*▪Solid rock*▪

* These substrates may vary greatly, in particular with regard to strength, com-position and porosity. Therefore, for each application the suitability of Sika® An-chorFix-2 Adhesive must be tested by first applying the Product only to a samplearea. Check in particular bond strength, surface staining and discoloration.

CHARACTERISTICS / ADVANTAGESFast curing▪Standard guns can be used▪High load capacity▪Drinking Water certified▪Non-sag, even overhead▪Styrene-free epoxy acrylate▪Low wastage▪Fixing close to free edges.▪Versatile range of embedment depths.▪Anchoring without expansion forces.▪

APPROVALS / STANDARDSEESR to AC308 by ICC-ES PENDING.▪ESR to AC308 by IAPMO-UES.▪Certified to ANSI / NSF - 61 by UL.▪

PRODUCT INFORMATIONPackaging 10 fl.oz. (299 ml) cartridge

Shelf Life 12 months from date of productionAll Sika® AnchorFix-2 cartridges have the expiry date printed on the label.

Storage Conditions Cartridges should be stored in their original packaging, the correct way up, incool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight.

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

1 / 8

TECHNICAL INFORMATIONTensile Adhesion Strength

The above values represent mean ultimate values and allowable working loads. The allowable working loadshave been reduced using a safety factor of 4.0 for tension and 3.0 for shear, however, in some cases, such aslife safety, safety factors of 10.0 or higher may be necessary.

1.

Allowable loads must be checked against steel capacity. The lowest value controls.2.Tabulated data is applicable to single anchors in normal weight concrete unaffected by edge or spacing re-duction factors. Values are valid for anchors installed into dry concrete in holes drilled with a hammer drilland ANSI carbide drill bit.

3.

Service temperatures should remain approximately constant. The maximum long term temperature being122 °F and the maximum short term temperature being 176 °F. Short term temperatures are those that oc-cur over brief intervals, for example, diurnal cycling.

4.

Linear interpolation is allowed.5.

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Service Temperature Long term 40 °F (4 °C) min. / 122 °F(50 °C) max.

Short term (1–2 hours) 176 °F (80 °C)

(ETAG 001, Part 5)

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

2 / 8

Design Considerations

Allowable Tension, Nall = 0.33 x fu x nominal cross sectional areaAllowable Shear, Vall = 0.17 x fu x nominal cross section area*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Tension = 0.33 x fu x nominal cross sectional areaShear = 0.17 x fu x nominal cross section area*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

3 / 8

SYSTEM INFORMATIONSystem Structure

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

APPLICATION INFORMATIONMixing Ratio Component A : component B = 10 : 1 by volume

Coverage

*Number of fixings assumes 30ml wastage in initial extrusion and holes filled to 3/4 full

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

4 / 8

Sag Flow Non-sag, even overhead

Product Temperature Sika® AnchorFix-2 must be at a temperature of between 41 °F (5 °C) to 68 °F(20 °C) for application.

Dew Point Beware of condensation.▪Beware of frost.▪

Open Time Working & Loading TimesCartridgeTemperature

T Work (minutes) Base MaterialTemperature

T Load (hours)

Minimum 41°F - 23 °F to 32 °F* 24 hoursMinimum 41 °F - 32 °F to 41°F 180 minutes41 °F to 50 °F 8 41 °F to 50 °F 100 minutes50 °F to 68 °F 4 50 °F to 68 °F 70 minutes68 °F to 77 °F 3 68 °F to 77 °F 40 minutes77 °F to 86 °F 2 77 °F to 86 °F 40 minutes86 °F 1 86 °F 40 minutesT Work is the typical time to gel at the highest temperature in the rangeT Load is the typical time to reach full capacity* The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

5 / 8

APPLICATION INSTRUCTIONSSUBSTRATE QUALITY

Mortar and concrete must be older than 28 days. Sub-strate strength (concrete, masonry, natural stone) mustbe verified. Pull-out tests must be carried out if the sub-strate strength is unknown. The anchor hole must al-ways be clean, dry, free from oil and grease etc. Looseparticles must be removed from the holes.Threaded rods and rebars have to be cleaned thor-oughly from any oil, grease or any other substances andparticles such as dirt etc.

MIXING

Getting the cartridge ready1. Unscrew the cap

2. Cut the film

3. Screw on the static mix-er

4. Place the cartridge intothe gun and start applica-tion

When the work is interrupted the static mixer can re-main on the cartridge after the gun pressure has beenrelieved. If the resin has hardened in the nozzle whenwork is resumed, a new nozzle must be attached.

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

6 / 8

APPLICATION METHOD / TOOLS

Anchors in solid masonry/concrete:Drilling of hole with anelectric drill to the diamet-er and depth required.Drill hole diameter mustbe in accordance with an-chor size.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole. (at least 2×)Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole (at least 2×).Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole (at least 2×).Important: use oil-freecompressors.

Pump approx. twice untilboth parts come out uni-formly. Do not use this ma-terial. Release the gunpressure and clean thecartridge opening with acloth.

Inject the adhesive intothe hole, starting from thebottom, while slowlydrawing back the staticmixer.In any case avoid en-trapping air. For deepholes extension tubing canbe used.

Insert the anchor with arotary motion into thefilled drill hole. Some ad-hesive must come out ofthe hole.Important: the anchormust be placed within theopen time.

During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skin thor-oughly with warm soapwater.

CLEANING OF TOOLS

Clean all tools and application equipment with Sika®Colma Cleaner immediately after use. Hardened / curedmaterial can only be mechanically removed.

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

7 / 8

AVAILABILITY/WARRANTYFor specific information on design refer to the separatedocumentation provided:Technical Documentation Sika® AnchorFix-2 870 43 02

BASIS OF PRODUCT DATAResults may differ based upon statistical variations de-pending upon mixing methods and equipment, temper-ature, application methods, test methods, actual siteconditions and curing conditions.

LOCAL RESTRICTIONSPrior to each use of any Sika product, the user must al-ways read and follow the warnings and instructions onthe product’s most current Product Data Sheet, productlabel and Safety Data Sheet which are available online athttp://usa.sika.com/ or by calling Sika's Technical Ser-vice Department at 800.933.7452 nothing contained inany Sika materials relieves the user of the obligation toread and follow the warnings and instructions for eachSika product for each Sika product as set forth in the cur-rent Product Data Sheet, product label and Safety DataSheet prior to product use.

ECOLOGY, HEALTH AND SAFETYKeep container tightly closed. Keep out of reach of chil-dren. Not for internal consumption. For industrial useonly. For professional use only. For further informationand advice regarding transportation, handling, storageand disposal of chemical products, users should refer tothe actual Safety Data Sheets containing physical, ecolo-gical, toxicological and other safety related data. Readthe current actual Safety Data Sheet before using theproduct. In case of emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887.

LEGAL NOTESPrior to each use of any Sika product, the user must al-ways read and follow the warnings and instructions onthe product’s most current Product Data Sheet, productlabel and Safety Data Sheet which are available online athttp://usa.sika.com/ or by calling Sika’s Technical Ser-vice Department at 800-933-7452. Nothing contained inany Sika materials relieves the user of the obligation toread and follow the warnings and instruction for eachSika product as set forth in the current Product DataSheet, product label and Safety Data Sheet prior toproduct use. SIKA warrants this product for one yearfrom date of installation to be free from manufacturingdefects and to meet the technical properties on the cur-rent Product Data Sheet if used as directed within shelflife. User determines suitability of product for intendeduse and assumes all risks. Buyer’s sole remedy shall belimited to the purchase price or replacement of productexclusive of labor or cost of labor. No other warrantiesexpress or implied shall apply including any warranty ofmerchantability or fitness for a particular purpose. Sikashall not be liable under any legal theory for special orconsequential damages. Sika shall not be responsible forthe use of this product in a manner to infringe on anypatent or any other intellectual property rights held byothers. Sale of Sika products are subject to Sika's termsand conditions of sale available at http://usa.sika.com/or by calling 201-933-8800.

SikaAnchorFix-2-en-US-(06-2018)-1-1.pdf

Sika Corporation201 Polito AvenueLyndhurst, NJ 07071Phone: 800-933-7452Fax: 201-933-6225

Sika Corporation30800 Stephenson HighwayMadison Heights, MI 48071U.S.A.Telephone: +1 248-577-0020Email: [email protected]

Sika Mexicana S.A. de C.V.Carretera Libre Celaya Km. 8.5Fracc. Industrial BalvaneraCorregidora, QueretaroC.P. 76920Phone: 52 442 2385800Fax: 52 442 2250537

Product Data SheetSika® AnchorFix-2June 2018, Version 01.01020205010020000001

8 / 8