product catalogue · dsp-based digital control, industrial communica-tions and process automation....

48
2016 Product Catalogue v 1.0

Upload: others

Post on 15-Dec-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

2016Product Catalogue

v 1.0

Page 2: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,
Page 3: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

Who we areCINERGIA is the result of more than ten years of experience in the conception, design, manufacture and commissioning of customized power electronics solutions. Our core competencies are the development of power electronics converters, DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the �elds of electrical conversion, electromobility, renewable resources and smart grids.

Our productsCINERGIA supplies high-technology products based on an industrial hardware platform designed to work 24/7. By using di�erent DSP �rmware, developed by CINERGIA, our standard product portfolio includes DC, AC and DC&AC power sink/sources.

RegenerativeThanks to its bidirectional topology all our products can regenerate the test energy back to the grid, reducing the energy consumption and optimizing the electrical installation.

Our valueWe provide cutting edge technology at cost-competitive prices thanks to the combination of a robust industrial platform with CINERGIA’s proprietary control system.

We can adapt our solutions to your speci�c needs and provide the engineering support to achieve the desired result thanks to the knowledge and experience of our engineering team.

CINERGIA develops and supplies AC and DC Regenerative Power Converters for Industrial, R&D and Academic applications

Page 4: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

DC platform

AC platform

GridEmulator

AC programmable

sourceCustomer

equipmentElectronic load(regenerative)

Grid AC/AC DC DeviceUnder test AC/AC

GridEmulator

DC programmable

sourceCustomer

equipmentElectronic load(regenerative)

Grid AC/DC DC DeviceUnder test DC/AC

ELECTROMOBILITYElectromomobility needs expertise in energy storage, batteries, battery charging, traction conver-ters, power supplies, communications and its control. CINERGIA supplies power electronics equipments and platforms for test in production lines, prototype validation, burn-in and R&D.

SMART GRIDSIEC de�nes the smart grid as an electricity network that intelligently integrate the actions of all its users- generators, consumers and those that do both. It is related with electrical vehicles, energy storage systems (ESS), renewable generation (DER), consumers , grid.tied/islanded systems, communication and energy manage-ment. CINERGIA can provide complete test solutions for Smartgrid Labs and Original Equip-ment Manufacturers.

SOLUTIONS

ACADEMIC AND R&DCINERGIA is your partner in Academic and R&D applications by adapting our standard products to the speci�c coming from academic and research requirements.

TEST PLATFORMSCINERGIA o�ers power electronics equipments, marked in green colour in the diagrams, as well as complete turn key solutions, for your testing needs: at the laboratory, production line, prototype and pre-series validation, burn-in, quality and R&D.

GridEmulator

BatteryCharger

AC/DCGridBms

+Batteries

BatteryEmulator

TractionConverter

VscInverter

Motor Generator

TestBench

AC/AC

ElectronicLoad

GridEmulator

BatteryEmulator Batteries

WindTurbine

Emulator

Grid

ElectricalVehicle

ElectricalVehicle

ElectronicLoad

MicrogridManager

BatteryCharger

(B2C)

BatteryCharger

PvEmulator u. DER e.

AcLoad

AC/AC DC/AC

Page 5: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

SELECTION GUIDE

Constant Voltage

Constant Current

Constant Power

Constant Resistance

Battery Charge

Battery Emulation

PAGE

13

18

23

28

AC Grid Emulat

or

GE-AC

Voltage Source

Current Source

Harmonics

Grid disturbances

10 to 400Hz

360 to 800Hz

PAGE

1

7

33

37† Contact us for further information

AC Electronic L

oad

EL-AC High Frequency

AC Electronic L

oad (E

L-AC)

AC&DC Voltage Source

GE-AC&DC

AC&DC Current S

ource

EL-AC&DC

DC Power Supply

DCPS DC Electronic L

oad

EL-DC Bidire

ctional B

attery

Charger

B2C Battery

Emulator

BE AC&DC Voltage Source

GE-AC&DC

AC&DC Current S

ource

EL-AC&DC

33

37

Page 6: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CINERGIA’s Grid Emulators are AC programmable voltage sources specially designed to create AC grids and emulate its disturbances. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.

FUNCTIONAL DESCRIPTION

Generation of AC grid systems:-Three-phase system (3F+N) up to 480Vrms line-line-Single-phase system (F+N) up to 277Vrms line-neutral-Programmable frequency from 10 to 400Hz-Programmable phase angle-Programmable internal resistance

Generation of grid disturbances:-Voltage harmonics up to 780Hz (except 8,10, 12 and 14th) -Flicker -Over and Undervoltage-Interruptions-Voltage dips symetric and unsymetric (types A, B, C, D).-Frequency �uctuations.-Automatic test �les (*.csv)

All disturbances can be con�gured in amplitude, duration and repetition time.

Applications:Test of UPS, Photovoltaic and Eolic Inverters, EV Quick Battery Chargers, Vehicle to Grid (V2G), Energy Storage Systems (ESS) and other AC devices.

KEY FEATURES

7.5 kVA – 200 kVA

4 Quadrant Power Supply

Regenerative up to 100% rated power

AC Output: 25 to 277 Vrms, phase-neutral43 to 480 Vrms, phase-phaseup to 230Arms per phase10-400Hz Independent con�guration per phase:- Voltage magnitude - Phase angle- Harmonics (up to 780Hz)

Disturbance generation:Interruptions and voltage dips, Flicker, Over and Undervoltage, Frequency Fluctuation

AC&DC version available

GE-AC Grid Emulator

GEA

C_2

016_

v1

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

1

Page 7: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM OF GE

AC Input is connected to the grid (neutral wire or DYn isolation transformer is required)

AC Output is connected to the Equipment Under Test (EUT) and can be used as:- Three-phase AC system- Three independent Single-phase AC systems (same frequency)- One parallelized Single-phase AC system (3 times rated current per phase)

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC voltages with programmable amplitude, phase angle and harmo-nic content by using a digital resonant control algorithm.

Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.

www.cinergia.coop

AC

Grid Emulator

GRID

DC AC

DC EQUIPMENT UNDER TEST

(EUT)

Optional

-U -U

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 P + NAC IN (GRID side) AC OUT (EUT side)

GE-AC Grid Emulator

GEA

C_2

016_

v1

2

Page 8: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

FUNCTIONALITIES

www.cinergia.coop

Undervoltage Voltage interruptions Balanced voltage dips

Frequency �uctuation400Hz Aeronautics Grid

Voltage Harmonics

Transient time 2-5ms

Independent phase harmonics Unbalanced voltage dips

Flicker

Balanced voltage dips

GE-AC Grid Emulator

GEA

C_2

016_

v1

3

Page 9: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

USER INTERFACE

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

Con�guration of harmonics Con�guration of disturbances

SOFTWARE FEATURES

GE-AC Grid Emulator

GEA

C_2

016_

v1

OptionsGalvanic IsolationIsolation monitorHigh Voltage (up to 295Vrms, p-n)Analog Input/Output PortRS485, RS232, CANLabview drivers

4

Page 10: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

Power 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 sOutput side (EUT side) AC Voltage Phase-neutral 25-277Vrms (10-100Hz) 25-210Vrms (101-200Hz) 25-150Vrms (201-400Hz) Rated AC Current1 Depends on model (see table) 10-230Arms Frequency Fundamental voltage 10-400Hz (0.1Hz resolution) Harmonics Per phase 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st above 100Hz Harmonic content Maximum % 1st: 100% 2nd-11th: 50%, 13th-15th:10% Modes of operation Constant Voltage Range2 Resolution3 Ripple3 9-100% <0.1% <1% Disturbance Generation Voltage dip and interruptions Over and Undervoltage Frequency variation Flicker Harmonic sequenceGeneral Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.

GE-AC Grid Emulator

GEA

C_2

016_

v1

5

Page 11: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

GE MODELS

GALVANIC ISOLATION (optional)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

RECOMMENDED CIRCUIT BREAKER

145145145145174217280381435458514612753

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

GE-AC Grid Emulator

GEA

C_2

016_

v1

GE7.5-ACGE10-ACGE15-ACGE20-ACGE30-ACGE40-ACGE50-ACGE60-ACGE80-ACGE100-ACGE120-ACGE160-ACGE200-AC

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENTAC rms / phase AC rms/ global Independent mode Parallel mode10A15A20A25A40A50A65A80A105A130A155A185A230A

30A45A60A75A120A150A195A240A315A390A465A555A690A

WEIGHTkg

770x450x1100

880x590x1320

850x900x2000

DIMENSIONSDxWxH (mm)

150150150150150185185185265290290540550

6

Page 12: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

AC Electronic Loads are power electronics devices that behave as an AC electrical load. While most electronic loads are dissipative, CINERGIA o�ers a comprehensive range of DC, AC and AC&DC full 4Q and full regenerative electronic loads.

FUNCTIONAL DESCRIPTION

Operation modes:-Constant Current (CC) -Constant Impedance (CI)-Constant Power (CP) -Automatic test from csv �le

Applications:R&D, production and reliability tests for applications requiring linear and non-linear AC loads. Test of AC voltage sources, UPS, AC generators and electrical devices (as fuses, circuit breakers and connectors).

In Smartgrid applications it can be used to emulate domestic appliances, a house, a building as well as grid-coupled generators: PV and eolic plants, Energy Storage Systems, Electrical Vehicles, V2G-Vehicle to Grid and other AC distributed generators.

80% typical energy and power saving:

KEY FEATURES

7.5 kVA – 200 kVA

4 Quadrant Power Supply

Regenerative up to 100% rated power

Full 4Q: pure capacitive and inductive current

AC Output: up to 230Arms per phase25 to 277 Vrms, phase-neutral10-400Hz

Independent con�guration per channel:- Fundamental current up to 400Hz- Harmonics up to 780Hz- Phase angle (-1 < cos � < 1) - Non-linear currents- Crest factor <3- Active / Reactive Power

AC&DC version available

EL-AC Electronic Load

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

GRIDEquipment Under Test

(EUT) 92 kW

8 kW100 kW11 1 .1kW

η=90%11.1 kW

19.1kW AC

Electronic Load

DC AC

DC η = 92%

92 kW

ELAC

_201

6_v1

7

Page 13: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM OF EL-AC

AC Input is connected to the grid (neutral wire or DYn isolation transformer is required)

AC Output is connected to the Equipment Under Test (EUT) and can be used as:- Three-phase AC Wye load (balanced or unbalanced)- Three independent Single-phase AC systems (di�erent voltage/frequency is possible)- One parallelized Single-phase AC system (3 times rated current per phase)

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC currents with programmable amplitude, phase angle and harmo-nic content by using a digital resonant control algorithm.

Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.

www.cinergia.coop

AC

Electronic Load

GRID

DC AC

DC EQUIPMENT UNDER TEST

(EUT)

Optional

-

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

AC IN (GRID side)3 P + N

AC OUT (EUT side)3 P + N

-

EL-AC Electronic Load

ELAC

_201

6_v1

8

Page 14: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

FUNCTIONALITIES

www.cinergia.coop

Resistive load Pure capacitive load Pure inductive load

Phase delay + harmonicsPhase delay

Single-phase recti�er

In previous oscilloscope captures: AC source under test (yellow), EL currents phase A, B and C (green, magenta, blue)

Three-phase recti�erHarmonics

Independent phase control

EL-AC Electronic Load

ELAC

_201

6_v1

9

Page 15: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

USER INTERFACE

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

Con�guration of harmonics Con�guration of disturbances

SOFTWARE FEATURES

EL-AC Electronic Load

ELAC

_201

6_v1

OptionsGalvanic IsolationIsolation monitorLow Current RippleHigh Voltage (up to 295Vrms, p-n)Analog Input/Output PortRS485, RS232, CANLabview drivers

10

Page 16: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

Power 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 sOutput side (EUT side) AC Voltage Rated maximum, ch-neutral 25-277Vrms (10-100Hz) 25-210Vrms (101-200Hz) 25-150Vrms (201-400Hz) Rated AC Current1 Independent mode 10-230Arms per channel Parallel mode 30-690Arms global Frequency Fundamental current 10-400Hz Power factor Con�gurable by user 0-1 (capacitive/inductive) Harmonic Con�gurable by user 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st at 400Hz Harmonic content Maximum % 1st-9th: 100% 11th: 50%, 13th-15th:10% Crest factor <3Modes of operation Range2 Resolution3 Ripple3 Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Impedance (R,L,C) min.-100% <±0.1% <1%General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage (Vrms) and Current (Irms) Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.

EL-AC Electronic Load

ELAC

_201

6_v1

11

Page 17: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

EL-AC MODELS

EL7.5-ACEL10-ACEL15-ACEL20-ACEL30-ACEL40-ACEL50-ACEL60-ACEL80-ACEL100-ACEL120-ACEL160-ACEL200-AC

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENTAC rms / phase AC rms/ global Independent mode Parallel mode10A15A20A25A40A50A65A80A105A130A155A185A230A

30A45A60A75A120A150A195A240A315A390A465A555A690A

WEIGHTkg

770x450x1100

880x590x1320

850x900x2000

DIMENSIONSDxWxH (mm)

GALVANIC ISOLATION (optional)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

EL-AC Electronic Load

ELAC

_201

6_v1

150150150150150185185185265290290540550

145145145145174217280381435458514612753

12

Page 18: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.

FUNCTIONAL DESCRIPTION

Operation modes:-Constant Voltage (CV)-Constant Current (CC)-Constant Power (CP)-Automatic test from csv �le

Three DC channels in each unit:The three channels can be controlled independently allowing di�erent voltage, current or power setpoints.

In standard units the Operation mode will be the same for the three channels. Optionally, each channel could be operated in di�erent mode (if interested, please ask for option Independent Channels Operation).

2Q or 4Q applications:-In 2Q applications, the EUT will be connected between one channel and the common negative. -In 4Q applications, the EUT will be connected between two channels

KEY FEATURES

6.75 – 160 kW

2/4 Quadrant Power Supply

Regenerative up to 100% rated power

1 channel Output: 20 to 750V, 0 to ±555A

3 channels Output:20 to 750V, 0 to ±185A/ch

Bipolar Output-350 to +350V, 0 to ±185A

+270V/0/-270V Outputfor Avionics applications

CV, CC, CP modes

Option for Independent Channels Operation

DCPS Programmable DC Power Supply

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

DC

PS_2

016_

v1

13

Page 19: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

DCPS Programmable DC Power Supply

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended)

DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.

Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.

www.cinergia.coop

AC

DC Power Supply

GRID

DC DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

-U -U

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 CH-COM

CH1CH2CH3Com_neg

AC IN (GRID side) DC OUT (EUT side)

DC

PS_2

016_

v1

14

Page 20: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

0.0

100.0

200.0

300.0

400.0

500.0

600.0

700.0

800.0

Out

put v

olta

ge (V

)

Output current (A)

USER INTERFACE

DCPS Programmable DC Power Supply

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE FEATURES

OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR

DC

PS_2

016_

v1

OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers

Minimum output voltage

Minimum voltageat rated power

Parallel channelsmode

Independent channels mode

In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:

Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.

Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.

In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.

This connection will be used to create +270V/0/-270V avionics DC bus system.

Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.

-400.0

-300.0

-200.0

-100.0

0.0

100.0

200.0

300.0

400.0

Out

put v

olta

ge (V

)

Output current (A)

-Bipolar +Bipolar

15

Page 21: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

DCPS Programmable DC Power Supply

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s

Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 minOperation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.

DC

PS_2

016_

v1

16

Page 22: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

DCPS Programmable DC Power Supply

www.cinergia.coop

MODELS

DCPS7.5DCPS10DCPS15DCPS20DCPS30DCPS40DCPS50DCPS60DCPS80DCPS100DCPS120DCPS160DCPS200

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V ±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

150150150150150185185185265290290540550

WEIGHTkg

770x450x1100

880x590x1320

850x900x2000

DIMENSIONSDxWxH (mm)

GALVANIC ISOLATION (recommended)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

RECOMMENDED CIRCUIT BREAKER

145145145145174217280381435458514612753

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

DC

PS_2

016_

v1

17

Page 23: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.

FUNCTIONAL DESCRIPTION

Operation modes:-Constant Current (CC)-Constant Power (CP)-Constant Resistance (CR)

Three DC channels:-The three channels can be controlled independently, allowing di�erent setpoints on each channel-The three channels can be controlled in parallel, sharing the same setpoint and providing 3 times the current-In Unipolar 2Q applications, the sources will be connected between one channel and the common negative. -In Bipolar 4Q applications, the source will be connected between two channels

80% typical energy saving by regenerating to the grid:

KEY FEATURES

6.75 – 160 kW

2/4 Quadrant Power Supply

Regenerative up to 100% rated power

1 channel Output: 20 to 750V, 0 to ±555A

3 channels Output:20 to 750V, 0 to ±185A/ch

Bipolar Output-350 to +350V, 0 to ±185A

+270V/0/-270V Outputfor Avionics applications

CV, CC, CP, CV modes

Option for Independent Channels Operation

AC&DC version available

EL-DC DC Electronic Load

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

-Constant Voltage (CV)-Automatic test from csv �le

GRIDEquipment Under Test

(EUT) 92 kW

8 kW100 kW11 1 .1kW

η=90%11.1 kW

19.1kW DC

Electronic Load

DC AC

DC η = 92%

92 kW

ELD

C_2

016_

v1

18

Page 24: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended)

DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.

Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.

www.cinergia.coop

AC

DC Electronic Load

GRID

DC DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

-U -U

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 CH-COM

CH1CH2CH3Com_neg

AC IN (GRID side) DC OUT (EUT side)

EL-DC DC Electronic Load

ELD

C_2

016_

v1

19

Page 25: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

0.0

100.0

200.0

300.0

400.0

500.0

600.0

700.0

800.0

Out

put v

olta

ge (V

)

Output current (A)

USER INTERFACE

EL-DC DC Electronic Load

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE FEATURES

OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR

ELD

C_2

016_

v1

OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers

Minimum output voltage

Minimum voltageat rated power

Parallel channelsmode

Independent channels mode

In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:

Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.

Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.

In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.

This connection will be used to create +270V/0/-270V avionics DC bus system.

Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.

-400.0

-300.0

-200.0

-100.0

0.0

100.0

200.0

300.0

400.0

Out

put v

olta

ge (V

)

Output current (A)

-Bipolar +Bipolar

20

Page 26: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s

Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100%‡ <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.

EL-DC DC Electronic Load

ELD

C_2

016_

v1

21

Page 27: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

MODELS

EL7.5-DCEL10-DCEL15-DCEL20-DCEL30-DCEL40-DCEL50-DCEL60-DCEL80-DCEL100-DCEL120-DCEL160-DCEL200-DC

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V

WEIGHTkg

DIMENSIONSDxWxH (mm)

GALVANIC ISOLATION (recommended)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

EL-DC DC Electronic Load

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

ELD

C_2

016_

v1

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

150150150150150185185185265290290540550

770x450x1100

880x590x1320

850x900x2000

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

145145145145174217280381435458514612753

22

Page 28: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.

FUNCTIONAL DESCRIPTION

Operation modes:-Battery Charge (BC) -Constant Voltage (CV)-Constant Current (CC) -Constant Power (CP)-Constant Resistance (CR) -Automatic test from csv �le Three DC channels in each unit:The three channels can be controlled independently allowing di�erent voltage, current or power setpoints.

In standard units the Operation mode will be the same for the three channels. Optionally, each channel can be opera-ted in di�erent mode (option Independent Channels Operation).

2Q or 4Q applications:For testing bipolar current applications and bipolar voltage applications.

Battery charge is controlled with an IUoU algorithm. Battery discharge can be done at constant current, power or resistance. Battery cycling is possible by programming a sequence in a csv �le.

KEY FEATURES

6.75 – 160 kW

2/4 Quadrant Power Supply

Regenerative up to 100% rated power

1 channel Output: 20 to 750V, 0 to ±555A

3 channels Output:20 to 750V, 0 to ±185A/ch

Bipolar Output-350 to +350V, 0 to ±185A

+270V/0/-270V Outputfor Avionics applications

BC, CV, CC, CP, CR modes

IUoU and Equalization battery charge modes

Constant current or power battery discharge

B2C Bidirectional Battery Charger

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

B2C

_201

6_v2

23

Page 29: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended)

DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications

BACK-TO-BACK TOPOLOGY

The converter is formed by a grid-side Active Recti�er and an output DCDC converter sharing a DC-link. The Active Recti�er allows sinusoidal current consumption with low harmonic distortion and unity power factor. The DCDC converter generates three independent DC voltages controlling the voltage, current or power.

www.cinergia.coop

AC

B2C

GRID

DC DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

-U -U

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 CH-COM

CH1CH2CH3Com_neg

AC IN (GRID side) DC OUT (EUT side)

B2C Bidirectional Battery Charger

B2C

_201

6_v2

24

Page 30: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

B2C Bidirectional Battery Charger

B2C

_201

6_v2

0.0

100.0

200.0

300.0

400.0

500.0

600.0

700.0

800.0

Out

put v

olta

ge (V

)

Output current (A)

USER INTERFACE

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE FEATURES

OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR

OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers

Parallel channelsmode

Independent channels mode

In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:

Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.

Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.

In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.

This connection will be used to create +270V/0/-270V avionics DC bus system.

Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.

-400.0

-300.0

-200.0

-100.0

0.0

100.0

200.0

300.0

400.0

Out

put v

olta

ge (V

)

Output current (A)

-Bipolar

25

Page 31: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s

Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1% Battery Charge 0-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-2

1 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.

B2C Bidirectional Battery Charger

B2C

_201

6_v2

26

Page 32: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

MODELS

B2C7.5B2C10B2C15B2C20B2C30B2C40B2C50B2C60B2C80B2C100B2C120B2C160B2C200

GALVANIC ISOLATION (recommended)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

B2C Bidirectional Battery Charger

All speci�cations are subject to change without notice.

7.51015203040506080100120160200

6.75913.518273645547290108128160

All speci�cations are subject to change without notice.

B2C

_201

6_v2

REFERENCE RATEDkVA kW

RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V

WEIGHTkg

DIMENSIONSDxWxH (mm)

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

150150150150150185185185265290290540550

770x450x1100

880x590x1320

850x900x2000

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

145145145145174217280381435458514612753

27

Page 33: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

A Battery Emulator is a power electronics device that behaves as a real battery pack. CINERGIA’s BE is based on a regenerative power DC supply. When emulating a battery charge, the energy will be injected back to the electrical grid consuming a sinusoidal current with unity power factor and low harmonic distortion. Using a BE will save space in the laboratory, avoiding safety issues of real batteries and allow a high �exibility in the tests.

FUNCTIONAL DESCRIPTION

Operation modes:-Constant Voltage (CV)-Static-Dynamic

Three DC channels:The three channels can be con�gured independently, allowing emulation of di�erent batteries at the same time

The three channels can be con�gured in parallel, emulating one single battery with 3 times the rated current capabilityv

Static mode: the emulated battery voltage will depend on the open-circuit voltage and internal charge and discharge virtual resistance.

Dynamic mode: the emulated battery voltage will depend on the State Of Charge, rate of discharge and internal charge and discharge virtual resistance.

KEY FEATURES

6.75 – 160 kW

2 Quadrant Power Supply

Regenerative up to 100% rated power

1 channel Output: 0 to 750V, 0 to ±555A

3 channels Output:0 to 750V, 0 to ±185A/ch

Constant Voltage, Static, and Dynamic modes

BE Battery Emulator

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

BE Battery Emulator

BE_2

016_

v1

28

Page 34: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended)

DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase)

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.

Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.

www.cinergia.coop

AC

Battery Emulator

GRID

DC DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

-U -U

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 CH-COM

CH1CH2CH3Com_neg

AC IN (GRID side) DC OUT (EUT side)

BE Battery Emulator

BE_2

016_

v1

29

Page 35: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

USER INTERFACE

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE INTERFACE

0.0

100.0

200.0

300.0

400.0

500.0

600.0

700.0

800.0

0 1ch mode3ch mode-3ch mode-1ch mode

Minimumvoltage atrated power

Out

put v

olta

ge (V

)

Output current (A)

OPERATION AREA: 1/3 CHANNELS

BE Battery Emulator

STATIC MODE

Voc

Rdisch

Rch

Vout

+

-

DYNAMIC MODE

CABINET

The battery is emulated through a simply�ed model based on �xed Voc and charge/discharge resistors.

A model based on battery manufacturer data allows realistic voltage and SOC behaviour.

BE_2

016_

v1

30

Page 36: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

RANGE AND SPECIFICATIONSMAGNITUDE VALUE

ower (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s

Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel DC Overcurrent 110% during 1 minOperation Modes Range2 Resolution3 Ripple3 Constant Voltage 5-100% <±0.1% <1% Static 5-±100% <±0.1% <1% Dynamic 5-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.

BE Battery Emulator

BE_2

016_

v1

31

Page 37: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

MODELS

BE7.5BE10BE15BE20BE30BE40BE50BE60BE80BE100BE120BE160BE200

7.51015203040506080100120160200

6.75913.518273645547290108128160

GALVANIC ISOLATION (recommended)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

BE Battery Emulator

OPTIONSGalvanic Isolation (recommended)Isolation monitorIsolated analog inputsRS485, RS232, CANLabview drivers

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

BE_2

016_

v1

REFERENCE RATEDkVA kW

RATED CURRENT Independent mode Parallel mode 0-750v 0-750v

WEIGHTkg

DIMENSIONSDxWxH (mm)

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

150150150150150185185185265290290540550

770x450x1100

880x590x1320

850x900x2000

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

145145145145174217280381435458514612753

32

Page 38: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

GE-AC&DC is the combination of two products in a single cabinet:a GE-AC and a DCPS. The equipment can be used alternatively in AC or in DC providing the highest �exibility at a very competitive price.Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.

FUNCTIONAL DESCRIPTION

Two main modes:- AC mode: the three output channels work as AC Voltage Sources as a GE-AC- DC mode: the three output channels work as DC Voltage Sources (CV) or DC Current Sources (CC, CP) as a DCPS

Three output channels:- Independent control- Parallel control

AC mode: -Generation of AC 3-phase or 1-phase voltages-Con�gurable frequency from 10 to 400Hz-Con�gurable phase angle and internal resistance-Generation of disturbancesSee GE-AC datasheet for further information

DC mode:-Operation modes: CV, CC and CP-Automatic test from Excel �le-Unipolar 2Q or Bipolar 4Q applications See DCPS datasheet for further information

KEY FEATURES

7.5 –200kVA / 6.75-160kW

4 Quadrant Power Supply

Regenerative up to 100% rated power

AC Output: 25 to 277 Vrms, phase-neutral43 to 480 Vrms, phase-phaseup to 230Arms per phase10-400Hz

DC Output: 1 channel Output: 20 to 750V, 0 to ±555A

3 channels Output:20 to 750V, 0 to ±185A/ch

Bipolar Output-350 to +350V, 0 to ±185A

+270V/0/-270V Outputfor Avionics applications

GE-AC&DC AC&DC Voltage Source

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

GE_

ACD

C_v

_v1

33

Page 39: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended )AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or DC output. The loads or EUT are connected between a phase and:- AC mode: the output neutral- DC mode: the common (COM) negative point for 2Q applications or to phase for 4Q applicationsThe AC or DC mode is selected by manual switch.

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be con�gured either as an AC inverter or as a DCDC converter.

www.cinergia.coop

AC

Grid Emulator

GRID

DC AC or DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 P + N + COM AC IN (GRID side) AC OUT (EUT side)

GE-AC&DC AC&DC Voltage Source

GE_

ACD

C_2

016_

v1

34

Page 40: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

USER INTERFACE

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

OptionsGalvanic IsolationIsolation monitorBattery Charge mode (BC)IAnalog Input/Output PortRS485, RS232, CANLabview drivers

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE FEATURES

Constant VoltageHarmonicsDisturbancesConstant Current Constant PowerConstant Resistance

√√√

√√√

AC mode DC mode

RANGE AND SPECIFICATIONSDetailed data can be found in datasheets of GE-AC and DCPS

GE-AC&DC AC&DC Voltage Source

GE_

ACD

C_2

016_

v1

35

Page 41: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

GE-AC&DC MODELS

GE7.5-AC&DCGE10-AC&DCGE15-AC&DCGE20-AC&DCGE30-AC&DCGE40-AC&DCGE50-AC&DCGE60-AC&DCGE80-AC&DCGE100-AC&DCGE120-AC&DCGE160-AC&DCGE200-AC&DC

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENTIndependent Mode Parallel modeArms/ch Adc/ch Arms Adc

WEIGHTkg

DIMENSIONSDxWxH (mm)

GALVANIC ISOLATION (recommended)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23

All speci�cations are subject to change without notice.

All speci�cations are subject to change without notice.

GE-AC&DC AC&DC Voltage Source

GE_

ACD

C_2

016_

v1

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

145145145145174217280381435458514612753

10A15A20A25A40A50A65A80A105A130A155A185A230A

30A45A60A75A120A150A195A240A315A390A465A555A690A

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

770x450x1100

880x590x1320

850x900x2000

150150150150150185185185265290290540550

36

Page 42: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

EL-AC&DC is the combination of two products in a single cabinet: an EL-AC and an EL-DC. The equipment can be used alternatively in AC or in DC providing the highest �exibility at a very competitive price.Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION

Two main modes:- AC mode: the three output channels work as AC Current Sources (CC, CP, CI) as EL-AC- DC mode: the three output channels work as a DC Voltage Source (CV) or a DC Current Source (CC, CP, CR) as EL-DC

Three output channels:- Independent control- Parallel control

AC mode: -Consumption of AC 3-phase or 1-phase current-100% con�gurable power factor, inductive and capacitive -Con�gurable harmonics-Operation modes: CC, CP, CI-Automatic test from Excel �le

DC mode:-Operation modes: CV, CC, CP and CR-Automatic test from Excel �le-Unipolar 2Q or Bipolar 4Q applications

KEY FEATURES

7.5 –200kVA / 6.75-160kW

4 Quadrant Power Supply

Regenerative up to 100% rated power

AC Output: 1-phase Output: up to 690Arms3-phase Output:up to 230Arms per channel 1 channel Output: 20 to 750V, 0 to ±555A

3 channels Output:20 to 750V, 0 to ±185A/ch

Bipolar Output-350 to +350V, 0 to ±185A

+270V/0/-270V Outputfor Avionics applications

Allowed Voltage: 25 to 277Vrms,p-n in AC20 to 750V in DC

CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358

EL-AC&DC AC&DC Electronic Load

VEL_

ACD

C_2

016_

v1

37

Page 43: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONCEPTUAL SCHEMATIC

TECHNICAL DIAGRAM

AC Input is connected to the grid (isolation transformer with neutral is recommended )AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or DC output. The loads or EUT are connected between a phase and:- AC mode: the output neutral- DC mode: the common (COM) negative point for 2Q applications or to phase for 4Q applicationsThe AC or DC mode is selected by manual switch.

BACK-TO-BACK TOPOLOGY

The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be con�gured either as an AC inverter or as a DCDC converter.

www.cinergia.coop

AC

Electronic Load

GRID

DC AC or DC

DC EQUIPMENT UNDER TEST

(EUT)

Recommended

EL-AC&DC AC&DC Electronic Load

EL_A

CD

C_2

016_

v1

EMC �lter

EMC �lter

DSP control

DSP control

Drivers x 6 Drivers x 6Current sensor x 3

Voltage sensor x 2

Voltage sensor x 3

Current sensor x 3

Voltage sensor x 3

HMI

CAN

MODBUS/TCPETHERNET

3 P + N 3 P + N + COM AC IN (GRID side) AC OUT (EUT side)

38

Page 44: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

USER INTERFACE

www.cinergia.coop

Local 3.2” Touchscreen panel

Remote Control port: LAN Ethernet with Modbus/TCP protocol.

Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop

Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V

Optional communications: RS485, RS232, CAN, LabView

CoolingThe power supply is air-cooled internally.

Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.

OptionsGalvanic Isolation (recommended)Isolation monitorAnalog Input/Output PortRS485, RS232, CANLabview drivers

Windows 7/10 user interface for remote operation and data acquisition.

SOFTWARE FEATURES

Constant CurrentHarmonicsConstant VoltageConstant PowerConstant ImpedanceConstant Resistance

√√

√√√

√√

AC mode DC mode

RANGE AND SPECIFICATIONSDetailed data can be found in datasheets of EL-AC and EL-DC

EL-AC&DC AC&DC Electronic Load

EL_A

CD

C_2

016_

v1

39

Page 45: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

www.cinergia.coop

GALVANIC ISOLATION (optional)

IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200

REFERENCE RECOMMENDED CIRCUIT BREAKER

WEIGHTkg

Inside the cabinet

595x415x708 (*)

789x490x865 (*)

964x684x1252 (*)

1192x744x1430 (*)

DIMENSIONSDxWxH (mm)

(*) The transformer is delivered in a stand-alone cabinet IP23All speci�cations are subject to change without notice.

EL-AC&DC AC&DC Electronic Load

EL_A

CD

C_2

016_

v1

EL-AC&DC MODELS

EL7.5-AC&DCEL10-AC&DCEL15-AC&DCEL20-AC&DCEL30-AC&DCEL40-AC&DCEL50-AC&DCEL60-AC&DCEL80-AC&DCEL100-AC&DCEL120-AC&DCEL160-AC&DCEL200-AC&DC

REFERENCE

7.51015203040506080100120160200

RATEDkVA kW

6.75913.518273645547290108128160

RATED CURRENTIndependent Mode Parallel modeArms/ch Adc/ch Arms Adc

WEIGHTkg

DIMENSIONSDxWxH (mm)

All speci�cations are subject to change without notice.

10A15A20A25A40A50A65A80A105A130A155A185A230A

30A45A60A75A120A150A195A240A315A390A465A555A690A

±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A

±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A

770x450x1100

880x590x1320

850x900x2000

150150150150150185185185265290290540550

Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A

145145145145174217280381435458514612753

40

Page 46: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

NOTES

41

Page 47: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,
Page 48: Product Catalogue · DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the ˜elds of electrical conversion,

CONTROL INTEL.LIGENT DE L’ENERGIA, SCCLPintor Roig i Soler 1008916 BadalonaBarcelonaSPAIN

T. +34 934 864 [email protected]