product guide - lab unlimited · erlab® d.f.s s.a.s - parc d’affaires des portes - bp 403 -...
TRANSCRIPT
erla
b® -
10/2
009
- . A
ll da
ta o
r ph
otog
raph
s in
this
broc
hure
are
not
con
trac
tual.
erl
ab® r
eser
ves
the
right
to m
odify
the
pres
ent d
ocum
ent w
ithou
t prio
r no
tice.
Prod
uct g
uide
EUROPE
FRANCE : erlab D.F.S. S.A.S. Headquarter Parc d’Affaires des Portes BP 403 27104 Val de Reuil Cedex Tel. : +33 (0)2 32 09 55 80 Fax. : +33 (0)2 32 09 55 90 E-Mail : [email protected]
U.K. : erlab D.F.S. S.A.S. UK and Ireland representation office Home Farm Buildings / Home Farm Netherhampton - Salisbury - SP2 8PJ Tel. : +44 (0)1722 341 940 Fax. : +44 (0)1722 341 950 E-Mail : [email protected]
GERMANY : erlab D.F.S. S.A.S. Vertretungsbüro Deutschland Siegburger Straße 215 - 50679 Köln Tel. : (0)800 330 47 31 Fax : (0)800 330 47 32 E-Mail : [email protected] Aus Österreich und der Schweiz: Tel: +33 (0)2 32 09 55 80 Fax: +33 (0)2 32 09 55 90
ITALY : erlab D.F.S. S.A.S. Ufficio di rappresentanza in Italia Via Leone XIII, 10 – 20145 Milano Tel. : +39 (0)2 89 00 771 Fax. : +39 (0)2 72 097 812 E-Mail : [email protected]
SPAIN : erlab S.L. Pol. Ind. Sur Passaje Newton 3A 08754 El Papiol-Barcelona Tel. : +34 93 673 24 74 Fax. : +34 93 673 24 76 E-Mail : [email protected]
NORTH AMERICA
U.S.A. : erlab inc. 388 Newburyport Turnpike Rowley, MA 01969 Tel : +1 (978) 948-2216 Fax : +1 (978) 948-3354 E-mail : [email protected]
ASIA
CHINA : Kunshan erlab D.F.S. co Ltd. 100 Liu Shi Jing, road Kunshan Development Zone Jiangsu Province Penglang - P.R. China 215333 Tel. : +86 (0) 512 5781 4085 Fax. : +86 (0) 512 5781 4082 E-mail : [email protected] MALAYSIA : erlab asia sdn bhd 25 Jalan Firma - /1 Kawasan Perindustrian Tebrau - 81 100 Johor Bahru, Johor State Tel. : +60 (0)7 3 555 724 Fax. : +60 (0)7 3 552 810 E-Mail : [email protected]
w w w . . c o m
International [email protected]
TM
Product Guide
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
321Midcap
M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
OptionsWork surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
External lighting Pivoting - 11 Watts - 400 Lux - IP 20
Mobicap Rolling cart made of anti-corrosion metallic alloy
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel
Acrylic
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
Equipments
Compliance to standards
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 8 mm thick acrylic
Filtration module Polypropylene
SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 45 watts(without lighting)
Amperage absorbed 1,6 amp.Sound level 52 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height Width Depth Height
MidcapM 321
800 620 1120 764 540 860
Types of filters available
The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
Molecular filter H14 HEPA filter
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Modular filtration columnMolecular filtration efficiency in
compliance with NFX 15-211: 2009 class 2 standard
H14 HEPA Filtration
Type 1CLiquid chemicals handlings
Type 1PPowders handlings
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
321Midcap
M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
*
* Total height according to filtration column type (mm)
Type 1P 1120Type 1C 1120
800 mm
192 mm
172 mm
332 mm
255 mm
764 mm
613 mm
1120 mm mini
1290 mm maxi
540 mm
620 mm
74 mm
420 mm
860 mm
30 mm
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
321Midcap
M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
Work surface N°1
Work surface N°2
540 mm
25 mm
764 mm
694 mm
540 mm
55 mm
764 mm
321 M
www.captair.com
TM
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
Equipments
Compliance to standards
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 8 mm thick acrylic
Filtration module Polypropylene
SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 45 watts(without lighting)
Amperage absorbed 1,6 amp.Sound level 52 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
M 321 800 6201120 mini1290 maxi
764 540 860
Types of filters available
The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Modular filtration column
Type 1PPowders handlings
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Mobicap Rolling cart made of anti-corrosion metallic alloy
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel
Acrylic
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
321 M
www.captair.com
TM
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
*
* Total height according to filtration column type (mm)
Type 1P 1120 Type 2C 1220Type 1C 1120 Type 1P 2C 1290Type 1P 1C 1220 Type 2C 1P 1290Type 1C 1P 1220
800 mm
192 mm
172 mm
332 mm
255 mm
764 mm
613 mm
1120 mm mini
1290 mm maxi
540 mm
620 mm
74 mm
420 mm
860 mm
30 mm
*
321 M
www.captair.com
TM
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
Work surface N°1
Work surface N°2
540 mm
25 mm
764 mm
694 mm
540 mm
55 mm
764 mm
391 M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
Equipments
Compliance to standards
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
M 391 1000 6201120 mini1290 maxi
965 540 860
Types of filters available
The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Mobicap Rolling cart made of anti-corrosion metallic alloy
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
SpecificationsNumber of columns 1Number of fans (IP44) 1Processed air flow 230 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 45 watts(without lighting)
Amperage absorbed 1,6 amp.Sound level 52 dbA
Modular filtration column
Type 1PPowders handlings
391 M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
1000 mm
192 mm
172 mm
332 mm
255 mm
965 mm
613 mm
1120 mm mini
1290 mm maxi
540 mm
620 mm
74 mm
420 mm
860 mm
30 mm
* Total height according to filtration column type (mm)
Type 1P 1120 Type 2C 1220Type 1C 1120 Type 1P 2C 1290Type 1P 1C 1220 Type 2C 1P 1290Type 1C 1P 1220
391 M
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
www.captair.comerlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
Work surface N°1
Work surface N°2
540 mm
965 mm
80 mm
965 mm
896 mm
580 mm
60 mm
481 M
www.captair.com
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
Equipments
Compliance to standards
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
SpecificationsNumber of columns 1
Number of fans (IP44) 1
Processed air flow 230 m3/h
Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 45 watts(without lighting)
Amperage absorbed 1,6 amp.
Sound level 52 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
M 481 1275 6201120 mini1290 maxi
1240 540 860
Types of filters available
The guarantee of your protection will be only ensured after the erlab®laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
481 M
www.captair.com
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
1275 mm
192 mm
172 mm
332 mm
255 mm
1240 mm
613 mm
1120 mm mini
1290 mm maxi
540 mm
620 mm
74 mm
420 mm
860 mm
30 mm
* Total height according to filtration column type (mm)
Type 1C 1120 Type 2C 1220Type 1P 1C 1220 Type 1P 2C 1290Type 1C 1P 1220 Type 2C 1P 1290
481 M
www.captair.com
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
TM
Work surface N°1
Work surface N°2
1240 mm
540 mm
80 mm
1170 mm
540 mm
60 mm
1240 mm
392 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
Modular filtration column
Type 1PPowders handlings
Equipments
Compliance to standards
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
SpecificationsNumber of columns 2Number of fans (IP44) 2Processed air flow 460 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 90 watts(without lighting)
Amperage absorbed 3,6 amp.Sound level 55 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
XLS 392
1000 7901290 mini1470 maxi
965 680 1038
Types of filters available
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
392 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
897 mm
274 mm
1000 mm
965 mm
958 mm
1290 mm mini
1470 mm maxi
680 mm
790 mm
74 mm
660 mm
1038 mm
30 mm
*
*
* Total height according to filtration column type (mm)
Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378
392 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
680 mm
965 mm
80 mm
965 mm
896 mm
680 mm
60 mm
Work surface N°1
Work surface N°2
483 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
Modular filtration column
Type 1PPowders handlings
Equipments
Compliance to standards
SpecificationsNumber of columns 3Number of fans (IP44) 3Processed air flow 690 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 135 watts (without lighting)
Amperage absorbed 4,8 amp.Sound level 58 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
XLS 483
1275 7901290 mini1470 maxi
1240 680 1038
Types of filters available
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
483 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1275 mm
325 mm
1240 mm
958 mm
1290 mm mini
1470 mm maxi
680 mm
790 mm
74 mm
660 mm
1038 mm
30 mm
*
*
* Total height according to filtration column type (mm)
Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378
483 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1240 mm
680 mm
80 mm
1170 mm
60 mm
1240 mm
680 mm
Work surface N°1
Work surface N°2
633 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
Equipments
Compliance to standards
SpecificationsNumber of columns 3Number of fans (IP44) 3Processed air flow 690 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 135 watts (without lighting)
Amperage absorbed 4,8 amp.Sound level 58 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
XLS 633
1600 7901290 mini1470 maxi
1566 680 1038
Types of filters available
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
633 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1600 mm
1566 mm
1300 mm
280 mm
* Total height according to filtration column type (mm)
Type 1C 1290 Type 2C 1398Type 1P 1C 1378 Type 1P 2C 1470Type 1C 1P 1378 Type 2C 1P 1470
958 mm
1290 mm mini
1470 mm maxi
680 mm
790 mm
74 mm
660 mm
1038 mm
30 mm
*
*
633 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1566 mm
80 mm
680 mm
1566 mm
1494 mm
680 mm
60 mm
Work surface N°1
Work surface N°2
714 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
Equipments
Compliance to standards
SpecificationsNumber of columns 4Number of fans (IP44) 4Processed air flow 920 m3/h Air velocity at the openings in working position 0,4 to 0,6 m/s
Voltage / Frequency 220 V / 50 Hz
Total power consumption 180 watts (without lighting)
Amperage absorbed 6,4 amp.Sound level 61 dbA
Technical specifications
Dimensions (mm)
Ref.External dimensions Internal dimensions - without work surface
Width Depth Height* Width Depth Height
XLS 714
1800 7901290 mini1470 maxi
1765 680 1038
Types of filters available
*According to filtration column type
Modular filtration columnClass 2 - (NFX 15-211 : 2009 standard) Class 1 - (NFX 15-211 : 2009 standard)
Type 1CLiquid chemicals handlings
Type 2C Liquid chemicals handlings
Type 1P 1CLiquid chemicals and powders handlings
Type 1P 2CLiquid chemicals and powders handlings
Type 1C 1PLiquid chemicals and powders handlings in clean room
Type 2C 1PLiquid chemicals and powders handlings in clean room
Molecular filter H14 HEPA filter
AFNOR NF X 15-211:2009 - France ANSI/ASHRAE 110-1995 - USA BS 7258 - England CSA Z316.5 - Canada
CE Marking NF P.92.507 (Acrylic part) EN 1822 : 1998 (H14 HEPA filter )
GF4 AS For organic vapours
GF4 BE + For organic vapours + acid vapours
GF4 F For formaldehyde vapours
GF4 K For ammonia vapours
GF4 HP H14 HEPA Filter for powders
The guarantee of your protection will be only ensured after the erlab® laboratory approval. Please contact your supplier and benefit from the ESP® (Erlab Safety Program) for a validation of the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.
Modular filtration column
Type 1PPowders handlings
Structure
Metallic parts Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating
Side and front panels 6 mm thick acrylic
Filtration module Polypropylene
Standard Equipment
Air flow meter Permanent air face velocity monitoring system
Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 68
Sampling port For filter saturation detection (N/A if Molecode S installed)
Programmable timer Timer - 60 hours setting by default ac-cording to NFX 15 211: 2009 standard
Energy ports For the passage of cables
Chemical Listing List of approved chemicals
Options
Molecode S* Automatic alarm to detect filter saturation by solvents according to NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)
Work surface N°1 Tempered glass work surface with seeled frame
Work surface N°2 In phenolic resin with built-in retention tray
Benchcap Fixed work bench made of anti-corrosion metallic alloy
Shelf Adjustable slinding shelf for Mobicap and Benchcap
Transparent back panel Acrylic
Access door on rear panel For maintenance interventions
Particular Pre-filter
40 % filtration efficiency for particles > 0,3 µm
714 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1800 mm
1765 mm
300 mm
1715 mm
958 mm
1290 mm mini
1470 mm maxi
680 mm
790 mm
74 mm
660 mm
1038 mm
30 mm
*
*
* Total height according to filtration column type (mm)
Type 1P 1290 Type 2C 1398Type 1C 1290 Type 1P 2C 1470Type 1P 1C 1378 Type 2C 1P 1470Type 1C 1P 1378
714 XLS
erlab® D.F.S S.A.S - Parc d’Affaires des Portes - BP 403 - 27104 Val de Reuil Cedex - FranceTel : +33 (0) 2 32 09 55 80 - Fax : + 33 (0) 2 32 09 55 90 - e-mail : [email protected]
Please consider the environment before printing this document.P
Mobile ductless filtration fume hood for personal protection during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter and particulate filtration on H14 HEPA filter.
Tech
nica
l dat
a ar
e no
t co
ntra
ctua
l. E
rlab
® r
eser
ves
the
righ
t to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
TM
www.captair.com
1765 mm
80 mm
680 mm
1765 mm
1694 mm
680 mm
60 mm
Work surface N°1
Work surface N°2