PANELS CANADA LTD.

selectorProduct

WWW.FALKPANELS.CA

“We look forward to working with you”

The FALK-team

What are you looking for?

ROOF / WALL panel (1000 TR & 1000 TR +) page 4

ROOF / WALL panel (1000 GL) page 5

ROOF panel (1000 TR PD) page 5 ROOF panel (1000 TR EKO & 1000 GL EKO) page 6

WALL panel (1060 WB) page 7

ROOFLIGHTS (1000 TR & 1000 GL) page 8

SINGLE SHEET cladding (TR & GL profiles) page 9 LOAD SPAN TABLES page 10-14

FALK can supply a complete panel package as well as all fasteners, rooflights, flashings, metal cladding, walk doors and other accessories. Want to know more? Please give us a call or send us an email. We’d love to hear from you.

PANELS CANADA LTD.

3

Icon legend

Available with Agri Coating. This coating is designed for long life in agricultural applications.

Available with EKO foil. The standard inner metal liner sheet can be replaced by a layer of white aluminium (foil). Cost efficient and well suited for agricultural applications.

This version is especially developed for potato storages. This product is characterized by an additional seal at the joints so that even with high relative humidity the seal guarantees a durable and condensation free wall and roof construction.

These products are suitable for the installations of solar panels. The number and type of fasteners is dependent on the mounting system, the thickness of the steel sheet and should be determined by the supplier of the solar panels.

Available with an anti-condensation felt on the bottom to prevent dripping.

AGRI-COATING

MOISTURE

SEAL

EKO

FOODSAFE

SUITABLE

Available with foodsafe coating especially developed for the food industry.

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

4

FALK Roof / Wall 1000 TR

• From 4 degrees roof pitch

• Optimum (double) sealing

• Positive stacking, quick installation

• Coating guarantee up to 30 years

• Supplied standard with foam seal at joints

• Optional alternative steel thicknesses and

coatings availableAGRI-COATING EKO SUITABLE SEAL

FALK Roof / Wall 1000 TR +

• From 4 degrees roof pitch

• Optimum (double) sealing

• Positive stacking, quick installation

• Hollow controlled joint system

• Coating guarantee up to 30 years

• Supplied standard with foam seal at joints

• Optional alternative steel thicknesses and

coatings available

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

40 mm  75 mm 0.41 13.74 10.50

60 mm  95 mm 0.29 19.37 11.30

80 mm  115 mm 0.23 25.01 12.10

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

100 mm  135 mm 0.19 30.66 12.90

125 mm 160 mm 0.16 37.70 13.90

150 mm  185 mm 0.13 44.73 14.90

200 mm

1000 mm

Co

re3

5 m

m200 mm

1000 mmC

ore

35

mm

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

(*) Based upon an external sheet thickness of 0.5 mm and internal sheet thickness of 0.4 mm.

(*) Based upon an external sheet thickness of 0.5 mm and internal sheet thickness of 0.4 mm.

FOODSAFE

AGRI-COATING EKO SUITABLE SEALFOODSAFE

5

Co

re4

0 m

m1000 mm

167 mm

FALK Roof 1000 TR PD

• Below 4 degrees roof pitch

• Optimum (double) sealing

• Hollow controlled joint system

• For new build and renovation

• Negative stacking, quick installation

• Supplied standard with foam seal at joints

• Optional alternative steel thicknesses and

coatings available

• Panel is to be used in conjuction with roofing membrane (by others)

SUITABLEFOODSAFE

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

100 mm 135 mm 0.19 30.66 12.90

125 mm 160 mm 0.16 37.70 13.90

150 mm 185 mm 0.13 44.73 14.90

(*) Based upon an external sheet thickness of 0.5 mm and internal sheet thickness of 0.4 mm.

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

(*) Based upon an external sheet thickness of 0.5 mm and internal sheet thickness of 0.4 mm.

FALK Roof / Wall 1000 GL

• Sinusoidal roof panel

• From 4 degrees roof pitch

• Optimum (double) sealing

• Positive stacking, quick installation

• Coating guarantee up to 30 years

• Optional alternative steel

thicknesses and coatings available

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

43 mm  83 mm 0.39 14.72 10.90

60 mm  100 mm 0.29 19.45 11.60

80 mm  120 mm 0.23 25.00 12.40

120 mm 160 mm 0.16 36.11 14.00

AGRI-COATING EKO SUITABLE SEALFOODSAFE

6

FALK Roof 1000 TR EKO

• From 4 degrees roof pitch

• Positive stacking, quick installation

• Ammonia resistant foil inside

• Coating guarantee up to 30 years

• Optional alternative steel thicknesses

and coatings available

SUITABLE

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

30 mm  65 mm 0.52 10.92 7.10

40 mm 75 mm 0.41 13.74 7.50

60 mm  95 mm 0.29 19.37 8.30

(*) Based upon an external sheet thickness of 0.5 mm.

Co

re3

5 m

m1000 mm

200 mm

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

(*) Based upon an external sheet thickness of 0.5 mm.

FALK Roof 1000 GL EKO

• From 4 degrees roof pitch

• 60/100 is produced with a

polyisocyanurate insulation core

• Ammonia resistant foil inside

• Coating guarantee up to 30 years

• Optional alternative steel

thicknesses and coatings available

Co

re4

0 m

m1000 mm

167 mm

Core thickness Total height U-value R-value Weight

(mm) (mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)*

31 mm  71 mm 0.49 11.39 7.20

43 mm  83 mm 0.39 14.72 7.60

60 mm  100 mm 0.29 19.45 8.30

SUITABLE

7PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

(*) Based upon an external sheet thickness of 0.63 mm and internal sheet thickness of 0.4 mm.

AGRI-COATINGFOODSAFE

Core thickness U-value R-value Weight

(mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2) *

60mm 0.37 16.67 12.00

80 mm 0.28 22.22 12.80

100 mm 0.22 27.78 13.60

120 mm 0.18 33.34 14.80

• In microrib, macrorib,

or box profiling

• Hidden fastener wall panel

• Durable joint shape and fit

• Can be installed horizontal

or vertical

• Coating guarantee up to 30 years

• Optional alternative steel

thicknesses and coatings available

FALK Exterior Wall 1060 WB

(*) Based upon an external sheet thickness of 0.50 mm and internal sheet thickness of 0.4 mm.

AGRI-COATINGFOODSAFE

Core thickness U-value R-value Weight

(mm) (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2) *

60mm 0.37 16.67 10.97

80 mm 0.28 22.22 11.77

100 mm 0.22 27.78 12.57

120 mm 0.18 33.34 13.77

• Hidden fastener interior wall panel

• Polyester coating

• Can be installed horizontal

or vertical

FALK Interior Wall 1060 WB

Co

re

1060 mm

0.7

mm

15.90 mm

1.4

mm

30.00 mm

macrorib exterior profile microrib exterior profile

0.7

mm

0.7

mm

box exterior profile box interior profile

47.75 mm 37.75 mm

0.7

mm

15.90 mm

1.4

mm

30.00 mm

macrorib exterior profile microrib exterior profile

0.7

mm

0.7

mm

box exterior profile box interior profile

47.75 mm 37.75 mm

8PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

• Suits the TR and TR EKO panel

• Double polycarbonate internal sheet

• Available in sandwich thicknesses of

30 to 80 mm

• Maximum length of 7000 mm (TR)

FALK Double Skin TR Rooflight

(*) Equal to FALK 1000 TR Roof/Wall Panel

Core thickness U-value R-value Weight

(mm) * (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)

30 to 80mm 2.70 2.10 Approx. 5.0

• Suits the GL and GL EKO panels

• Double polycarbonate internal

sheet

• Available in sandwich thicknesses

of 30 to 80 mm

• Maximum length of 7000 mm (GL)

FALK Double Skin GL Rooflight

(*) Equal to FALK 1000 GL Roof/Wall panel.

Core thickness U-value R-value Weight

(mm) * (W/m2. K) (h.ft2.OF/BTU. in) (kg/m2)

30 to 80mm 2.70 2.10 Approx. 5.0

9PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

FALK 1000/35 TR Roof / Wall

Sheet thicknesses Weight

(mm) (kg./m²)

0.55 5.7

100

FALK 1000/35 DAK

FALK 1000/35 WAND

1000 MM

10050200

10010050200

1000 MM

35

35

50

126˚ 35

45

25

R11

• Available with anti-condensation felt

• For new build and renovation

• Optional alternative coatings available

• Coating guarantee up to 30 years

Roof profile

Wall profile

SUITABLE MOISTURE

FALK 1000/40 GL Roof / Wall

Sheet thicknesses Weight

(mm) (kg./m²)

0.55 5.7

0.63 6.4

167

40

45

R42

FALK 1000/40 GL DAK

FALK 1000/40 GL WAND

1000 MM

167

40

1000 MM

167

40

• For new builds and renovations

• Available with anti-condensation felt

• Optional alternative coatings available

• Coating guarantee up to 30 years

SUITABLE MOISTURE

10

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 20.5 25.0 29.0 33.0 37.5 41.5 45.5 50.0 54.0 58.0

SINGLE SPAN STRENGTH 10.6 9.4 8.5 7.8 7.2 6.6 6.2 5.9 5.6 5.3(L/180) 10.6 9.4 8.5 7.8 7.1 6.6 6.2 5.9 5.5 5.3

50/85 DOUBLE SPAN STRENGTH 10.6 9.4 8.5 7.8 7.2 6.6 6.2 5.9 5.6 5.3(L/180) 10.6 9.4 8.5 7.8 7.1 6.6 6.2 5.9 5.5 5.3

MULTIPLE SPAN STRENGTH 10.6 9.4 8.5 7.8 7.2 6.6 6.2 5.9 5.6 5.3(L/180) 10.6 9.4 8.5 7.8 7.1 6.6 6.2 5.9 5.5 5.3

SINGLE SPAN STRENGTH 11.6 10.3 9.3 8.4 7.7 7.1 6.7 6.2 5.9 5.6(L/180) 11.6 10.3 9.2 8.4 7.7 7.1 6.6 6.2 5.9 5.6

60/95 DOUBLE SPAN STRENGTH 11.6 10.3 9.3 8.4 7.7 7.1 6.7 6.2 5.9 5.6(L/180) 11.6 10.3 9.2 8.4 7.7 7.1 6.7 6.2 5.9 5.6

MULTIPLE SPAN STRENGTH 11.6 10.3 9.3 8.4 7.7 7.1 6.7 6.2 5.9 5.6(L/180) 11.6 10.3 9.2 8.4 7.7 7.1 6.6 6.2 5.9 5.6

SINGLE SPAN STRENGTH 13.7 12.2 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3(L/180) 13.7 12.1 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3

80/115 DOUBLE SPAN STRENGTH 13.7 12.2 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3(L/180) 13.7 12.1 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3

MULTIPLE SPAN STRENGTH 13.7 12.2 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3(L/180) 13.7 12.1 10.9 9.9 9.0 8.3 7.7 7.1 6.7 6.3

SINGLE SPAN STRENGTH 15.8 14.1 12.6 11.4 10.4 9.6 8.8 8.2 7.6 7.1(L/180) 14.1 12.9 12.0 11.2 10.4 9.5 8.8 8.2 7.6 7.1

100/135 DOUBLE SPAN STRENGTH 15.8 14.1 12.6 11.4 10.4 9.6 8.8 8.2 7.6 7.1(L/180) 15.8 14.0 12.6 11.4 10.4 9.5 8.8 8.2 7.6 7.1

MULTIPLE SPAN STRENGTH 15.8 14.1 12.6 11.4 10.4 9.6 8.8 8.2 7.6 7.1(L/180) 15.8 14.0 12.6 11.4 10.4 9.5 8.8 8.2 7.6 7.1

SINGLE SPAN STRENGTH 16.5 14.5 12.9 11.7 10.7 9.9 9.2 8.5 8.0 7.6(L/180) 14.9 13.7 12.6 11.6 10.7 9.9 9.2 8.5 8.0 7.6

125/160 DOUBLE SPAN STRENGTH 16.5 14.5 12.9 11.7 10.7 9.9 9.2 8.5 8.0 7.6(L/180) 16.5 14.5 12.9 11.7 10.7 9.9 9.2 8.5 8.0 7.6

MULTIPLE SPAN STRENGTH 16.5 14.5 12.9 11.7 10.7 9.9 9.2 8.5 8.0 7.6(L/180) 16.5 14.5 12.9 11.7 10.7 9.9 9.2 8.5 8.0 7.6

SINGLE SPAN STRENGTH 17.1 14.9 13.3 12.0 11.0 10.2 9.5 8.9 8.4 8.0(L/180) 15.8 14.5 13.3 12.0 11.0 10.2 9.5 8.9 8.4 8.0

150/185 DOUBLE SPAN STRENGTH 17.1 14.9 13.2 12.0 11.0 10.2 9.5 8.9 8.4 8.0(L/180) 17.1 14.9 13.3 12.0 11.0 10.2 9.5 8.9 8.4 8.0

MULTIPLE SPAN STRENGTH 17.1 14.9 13.2 12.0 11.0 10.2 9.5 8.9 8.4 8.0(L/180) 17.1 14.9 13.3 12.0 11.0 10.2 9.5 8.9 8.4 8.0

DESIGN LOAD (PSF) - POSITIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Roof / Wall 1000 TR and TR + Load Span Table (feet) - Positive Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

11

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 10.0 14.5 18.5 22.5 27.0 31.0 35.5 39.5 43.5 48.0

SINGLE SPAN STRENGTH 20.4 17.0 14.8 13.4 12.4 11.5 10.8 10.3 9.8 9.4(L/180) 18.9 16.5 14.5 13.1 12.0 11.2 10.5 10.0 9.6 9.1

50/85 DOUBLE SPAN STRENGTH 20.4 16.9 14.9 13.4 12.1 10.9 10.1 9.3 8.7 8.3(L/180) 19.8 16.5 14.5 13.1 12.0 11.0 10.1 9.4 8.8 8.3

MULTIPLE SPAN STRENGTH 20.4 16.9 14.8 13.4 12.4 11.5 10.8 10.2 9.6 9.0(L/180) 17.9 15.4 13.7 12.5 11.6 10.9 10.3 9.8 9.3 8.7

SINGLE SPAN STRENGTH 21.7 18.0 15.8 14.2 13.0 12.1 11.4 10.8 10.3 9.9(L/180) 20.4 17.6 15.4 13.9 12.8 11.9 11.2 10.6 10.1 9.7

60/95 DOUBLE SPAN STRENGTH 21.7 18.0 15.7 14.2 12.7 11.6 10.6 9.8 9.2 8.6(L/180) 21.2 17.6 15.4 13.9 12.8 11.6 10.6 9.9 9.2 8.7

MULTIPLE SPAN STRENGTH 21.7 18.0 15.7 14.2 13.0 12.2 11.4 10.7 10.0 9.4(L/180) 21.2 17.6 15.4 13.9 12.8 11.9 11.2 10.6 10.0 9.4

SINGLE SPAN STRENGTH 24.2 20.0 17.5 15.7 14.4 13.4 12.6 11.9 11.3 10.8(L/180) 23.1 19.7 17.2 15.5 14.2 13.2 12.4 11.7 11.2 10.7

80/115 DOUBLE SPAN STRENGTH 24.2 20.0 17.5 15.7 14.1 12.7 11.7 10.8 10.0 9.4(L/180) 23.9 19.7 17.2 15.5 14.2 12.8 11.7 10.8 10.1 9.5

MULTIPLE SPAN STRENGTH 24.2 20.0 17.5 15.7 14.4 13.4 12.6 11.7 10.9 10.2(L/180) 23.9 19.7 17.2 15.5 14.2 13.2 12.4 11.7 10.9 10.2

SINGLE SPAN STRENGTH 26.6 21.9 19.1 17.2 15.7 14.6 13.7 12.9 12.3 11.8(L/180) 26.6 21.9 19.1 17.2 15.7 14.6 13.7 12.9 12.3 11.8

100/135 DOUBLE SPAN STRENGTH 26.6 21.9 19.1 17.2 15.4 13.9 12.7 11.7 10.8 10.2(L/180) 26.6 21.9 19.1 17.2 15.4 13.9 12.7 11.7 10.8 10.2

MULTIPLE SPAN STRENGTH 26.6 21.9 19.1 17.2 15.7 14.6 13.7 12.6 11.7 10.9(L/180) 26.6 21.9 19.1 17.2 15.7 14.6 13.7 12.6 11.7 10.9

SINGLE SPAN STRENGTH 29.3 24.1 21.0 18.8 17.2 16.0 15.0 14.2 13.4 12.8(L/180) 29.3 24.1 21.0 18.8 17.2 16.0 15.0 14.2 13.4 12.8

125/160 DOUBLE SPAN STRENGTH 29.3 24.1 21.0 18.7 16.5 14.8 13.5 12.4 11.5 10.7(L/180) 29.3 24.1 21.0 18.7 16.5 14.8 13.5 12.4 11.5 10.7

MULTIPLE SPAN STRENGTH 29.3 24.1 21.0 18.8 17.2 15.8 14.5 13.3 12.3 11.5(L/180) 29.3 24.1 21.0 18.8 17.2 15.8 14.5 13.3 12.3 11.5

SINGLE SPAN STRENGTH 32.1 26.3 22.9 20.5 18.7 17.4 16.3 15.4 14.6 13.9(L/180) 32.1 26.3 22.9 20.5 18.7 17.4 16.3 15.4 14.6 13.9

150/185 DOUBLE SPAN STRENGTH 32.1 26.3 22.9 20.1 17.6 15.8 14.3 13.1 12.2 11.3(L/180) 32.1 26.3 22.9 20.1 17.6 15.8 14.3 13.1 12.2 11.3

MULTIPLE SPAN STRENGTH 32.1 26.3 22.9 20.5 18.7 16.9 15.3 14.0 12.9 12.0(L/180) 32.1 26.3 22.9 20.5 18.7 16.9 15.3 14.0 12.9 12.0

DESIGN LOAD (PSF) - NEGATIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Roof / Wall 1000 TR and TR + Load Span Table (feet) - Negative Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

12

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 20.5 25.0 29.0 33.0 37.5 41.5 45.5 50.0 54.0 58.0

SINGLE SPAN STRENGTH 9.2 8.2 7.4 6.9 6.4 6.1 5.7 5.5 5.2 5.0(L/180) 9.2 8.2 7.5 6.9 6.4 6.1 5.7 5.5 5.2 5.0

43/83 DOUBLE SPAN STRENGTH 9.2 8.2 7.4 6.9 6.4 6.0 5.7 5.5 5.2 5.0(L/180) 9.2 8.2 7.5 6.9 6.4 6.1 5.7 5.5 5.2 5.0

MULTIPLE SPAN STRENGTH 9.2 8.2 7.4 6.9 6.4 6.0 5.7 5.5 5.2 5.0(L/180) 9.2 8.2 7.5 6.9 6.4 6.1 5.7 5.5 5.2 5.0

SINGLE SPAN STRENGTH 10.3 9.1 8.2 7.5 7.0 6.5 6.2 5.9 5.6 5.4(L/180) 10.3 9.1 8.3 7.6 7.0 6.6 6.2 5.9 5.6 5.4

60/100 DOUBLE SPAN STRENGTH 10.3 9.1 8.2 7.5 7.0 6.5 6.2 5.9 5.6 5.4(L/180) 10.3 9.1 8.3 7.6 7.0 6.6 6.2 5.9 5.6 5.4

MULTIPLE SPAN STRENGTH 10.3 9.1 8.2 7.5 7.0 6.5 6.2 5.9 5.6 5.4(L/180) 10.3 9.1 8.3 7.6 7.0 6.6 6.2 5.9 5.6 5.4

SINGLE SPAN STRENGTH 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.8(L/180) 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.9

80/120 DOUBLE SPAN STRENGTH 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.8(L/180) 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.9

MULTIPLE SPAN STRENGTH 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.8(L/180) 11.7 10.3 9.2 8.4 7.8 7.2 6.8 6.4 6.1 5.9

SINGLE SPAN STRENGTH 14.7 12.7 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8(L/180) 14.7 12.8 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8

120/160 DOUBLE SPAN STRENGTH 14.7 12.7 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8(L/180) 14.7 12.8 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8

MULTIPLE SPAN STRENGTH 14.7 12.7 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8(L/180) 14.7 12.8 11.3 10.3 9.4 8.7 8.1 7.6 7.2 6.8

DESIGN LOAD (PSF) - POSITIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Roof / Wall 1000 GL - Load Span Table (feet) - Positive Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

13

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 10.0 14.5 18.5 22.5 27.0 31.0 35.5 39.5 43.5 48.0

SINGLE SPAN STRENGTH 20.0 16.6 14.5 13.1 12.1 11.2 10.5 10.0 9.5 9.1(L/180) 18.6 15.8 14.1 12.8 11.8 11.0 10.4 9.9 9.4 9.0

43/83 DOUBLE SPAN STRENGTH 20.0 16.6 14.5 12.9 11.4 10.4 9.5 8.8 8.3 7.8(L/180) 20.0 16.6 14.5 12.9 11.4 10.4 9.5 8.8 8.3 7.8

MULTIPLE SPAN STRENGTH 20.0 16.6 14.5 13.1 12.1 11.2 10.4 9.6 9.0 8.4(L/180) 20.0 16.6 14.5 13.1 12.1 11.2 10.4 9.6 9.0 8.4

SINGLE SPAN STRENGTH 22.3 18.5 16.1 14.5 13.3 12.4 11.6 11.0 10.4 10.0(L/180) 21.7 18.5 16.1 14.5 13.3 12.4 11.6 11.0 10.4 10.0

60/100 DOUBLE SPAN STRENGTH 22.3 18.5 16.1 13.9 12.3 11.1 10.1 9.3 8.7 8.2(L/180) 22.3 18.5 16.1 13.9 12.3 11.1 10.1 9.3 8.7 8.2

MULTIPLE SPAN STRENGTH 22.3 18.5 16.1 14.5 13.3 12.1 11.0 10.1 9.4 8.8(L/180) 22.3 18.5 16.1 14.5 13.3 12.1 11.0 10.1 9.4 8.8

SINGLE SPAN STRENGTH 24.8 20.5 17.9 16.0 14.7 13.7 12.8 12.1 11.5 11.0(L/180) 24.8 20.5 17.9 16.0 14.7 13.7 12.8 12.1 11.5 11.0

80/120 DOUBLE SPAN STRENGTH 24.8 20.5 17.2 14.7 13.0 11.7 10.6 9.8 9.1 8.5(L/180) 24.8 20.5 17.2 14.7 13.0 11.7 10.6 9.8 9.1 8.5

MULTIPLE SPAN STRENGTH 24.8 20.5 17.9 16.0 14.2 12.7 11.5 10.6 9.8 9.1(L/180) 24.8 20.5 17.9 16.0 14.2 12.7 11.5 10.6 9.8 9.1

SINGLE SPAN STRENGTH 29.4 24.2 21.1 18.9 17.3 16.0 15.0 14.2 13.5 12.8(L/180) 29.4 24.2 21.1 18.9 17.3 16.0 15.0 14.2 13.5 12.5

120/160 DOUBLE SPAN STRENGTH 29.4 23.0 18.7 15.9 13.9 12.4 11.3 10.3 9.6 8.9(L/180) 29.4 23.0 18.7 15.9 13.9 12.4 11.3 10.3 9.6 8.9

MULTIPLE SPAN STRENGTH 29.4 24.2 20.4 17.2 15.0 13.3 12.1 11.0 10.2 9.5(L/180) 29.4 24.2 20.4 17.2 15.0 13.3 12.1 11.0 10.2 9.5

DESIGN LOAD (PSF) - NEGATIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Roof / Wall 1000 GL - Load Span Table (feet) - Negative Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

14

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 20.5 25.0 29.0 33.0 37.5 41.5 45.5 50.0 54.0 58.0

SINGLE SPAN STRENGTH 15.8 14.4 13.3 12.5 11.8 11.2 10.6 10.2 9.8 9.4(L/180) 11.8 10.8 10.1 9.4 8.8 8.3 7.9 7.6 7.2 6.9

60 DOUBLE SPAN STRENGTH 15.8 14.4 13.3 12.5 11.8 11.2 10.6 10.2 9.8 9.4(L/180) 14.3 12.9 11.9 10.9 10.2 9.5 8.9 8.4 8.0 7.6

MULTIPLE SPAN STRENGTH 15.8 14.4 13.3 12.5 11.8 11.2 10.6 10.2 9.8 9.4(L/180) 13.8 12.6 11.6 10.7 10.0 9.4 8.9 8.4 8.0 7.6

SINGLE SPAN STRENGTH 18.3 16.7 15.5 14.5 13.6 12.9 12.3 11.8 11.3 10.9(L/180) 14.6 13.5 12.5 11.8 11.1 10.5 10.0 9.5 9.1 8.7

80 DOUBLE SPAN STRENGTH 18.3 16.7 15.5 14.5 13.6 12.9 12.3 11.8 11.3 10.9(L/180) 17.9 16.3 14.9 13.9 12.9 12.1 11.4 10.8 10.2 9.7

MULTIPLE SPAN STRENGTH 18.3 16.7 15.5 14.5 13.6 12.9 12.3 11.8 11.3 10.9(L/180) 17.3 15.8 14.5 13.5 12.7 11.9 11.3 10.7 10.2 9.7

SINGLE SPAN STRENGTH 20.5 18.7 17.3 16.2 15.3 14.5 13.8 13.2 12.7 12.3(L/180) 17.3 15.9 14.8 13.9 13.1 12.5 11.9 11.3 10.8 10.4

100 DOUBLE SPAN STRENGTH 20.5 18.7 17.3 16.2 15.3 14.5 13.8 13.2 12.7 12.3(L/180) 20.5 18.7 17.3 16.2 15.3 14.5 13.7 13.0 12.4 11.8

MULTIPLE SPAN STRENGTH 20.5 18.7 17.3 16.2 15.3 14.5 13.8 13.2 12.7 12.3(L/180) 20.4 18.7 17.3 16.1 15.1 14.3 13.5 12.8 12.2 11.7

SINGLE SPAN STRENGTH 22.5 20.6 19.0 17.8 16.8 15.9 15.2 14.5 14.0 13.4(L/180) 19.5 18.0 16.7 15.7 14.8 14.0 13.3 12.7 12.2 11.7

120 DOUBLE SPAN STRENGTH 22.5 20.6 19.0 17.8 16.8 15.9 15.2 14.5 14.0 13.4(L/180) 22.5 20.6 19.0 17.8 16.8 15.9 15.2 14.5 13.8 13.1

MULTIPLE SPAN STRENGTH 22.5 20.6 19.0 17.8 16.8 15.9 15.2 14.5 14.0 13.4(L/180) 22.5 20.6 19.0 17.8 16.8 15.9 15.2 14.5 13.8 13.1

DESIGN LOAD (PSF) - POSITIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Exterior Wall 1060 WB - Load Span Table (feet) - Positive Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

15

PANEL SPAN DESIGNTHICKNESS CONDITION CRITERIA 10.0 14.5 18.5 22.5 27.0 31.0 35.5 39.5 43.5 48.0

SINGLE SPAN STRENGTH 17.7 14.9 13.2 11.9 10.9 10.2 9.6 9.0 8.6 8.2(L/180) 16.0 13.9 12.4 11.3 10.4 9.7 9.1 8.6 8.2 7.7

60 DOUBLE SPAN STRENGTH 17.7 14.9 13.2 11.9 10.9 10.2 9.6 9.0 8.6 8.2(L/180) 17.7 14.9 13.2 11.9 10.9 10.2 9.6 9.0 8.6 8.2

MULTIPLE SPAN STRENGTH 17.7 14.9 13.2 11.9 10.9 10.2 9.6 9.0 8.6 8.2(L/180) 17.7 14.9 13.2 11.9 10.9 10.2 9.6 9.0 8.6 8.2

SINGLE SPAN STRENGTH 19.6 17.3 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5(L/180) 19.6 17.1 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5

80 DOUBLE SPAN STRENGTH 20.5 17.3 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5(L/180) 20.5 17.3 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5

MULTIPLE SPAN STRENGTH 20.5 17.3 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5(L/180) 20.5 17.3 15.3 13.8 12.7 11.8 11.1 10.5 10.0 9.5

SINGLE SPAN STRENGTH 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7(L/180) 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7

100 DOUBLE SPAN STRENGTH 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7(L/180) 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7

MULTIPLE SPAN STRENGTH 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7(L/180) 23.0 19.4 17.1 15.5 14.2 13.2 12.5 11.8 11.2 10.7

SINGLE SPAN STRENGTH 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7(L/180) 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7

120 DOUBLE SPAN STRENGTH 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7(L/180) 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7

MULTIPLE SPAN STRENGTH 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7(L/180) 25.2 21.3 18.8 17.0 15.6 14.5 13.7 12.9 12.3 11.7

DESIGN LOAD (PSF) - NEGATIVE PRESSURE

Notes: 1. Exterior face is 24 gauge steel; interior face is 26 gauge steel2. Allowable span may be governed by strength limit or deflection limit. (Use the lower allowable span)3. Connection strength varies with the values of the loads, direction of the loads (positive or negative), spacing of the sup-

porting members and types of fasteners. (Contact Falk Panels Canada for specific project requirements.)4. Thermal loading and temperature differentials have not been considered.5. The design and structural capacity of all the support members are the responsibilty of others.6. Contact Falk Panels Canada for any additional requirements not noted in this table.7. Panels tested in accordance with ASTM E72 & European Standard Testing Requirements for Insulated Metal Panels

FALK Exterior Wall 1060 WB - Load Span Table (feet) - Negative Pressure

PANELS CANADA LTD. T. +1 (587) 349–1777 www.falkpanels.ca

ABOUT FALK

Progress and ambition. That is what distinguishes FALK.

Our roof and wall systems will make a difference for you.

Our mentality is that almost anything is possible. The

challenge is to outdo ourselves with smart solutions. You

will always benefit from the best product for your project.

We create and deliver product to meet your needs.

FALK makes a difference.

PANELS CANADA LTD.

vers

ion:

20

18-1

2Disclaimer © FALK Bouwsystemen B.V. and FALK Panels Canada Ltd. have taken care to ensure that the contents of this product selector are accurate. Suggestions for, or description of, the end use or application of products or methods of working are for information only and FALK Bouwsystemen B.V. and FALK Panels Canada Ltd. accept no liability in respect thereof.

FALK Panels Canada LTD.

T. +1 (587) 349–1777

www.falkpanels.ca

100% MADE IN HOLLAND

100%

MADE IN

HOLLAND

100%

MADE IN

HOLLAND

QAI is a Standards Council of Canada and International Accreditation Service, Inc. accredited Product Certification Agency, Inspection Agency and Testing Laboratory for Insulated Metal Panel products and evaluation for structural, durability and fire resistance behaviour. Results have been published and can viewed in the QAI Listing Directory.

Falk Bouwsystemen BV, is FM Approved for 4471, 4880 and 4881 classes. Please contact Falk Panels Canada Ltd. for approved installation requirements.

Panels tested in accordance with ASTM C518, ASTM E283, ASTM E331, ASTM E330, ASTM E72, ASTM D1623, ASTM E84, ASTM C1363, CAN/ULC S101, CAN/ULC S102, CAN/ULC S127, CAN/ULC S138, FM 4471, FM 4880, FM4880 and European Standard Testing Requirements for Insulated Metal Panels. Please contact us for more information.