Insulation Low Energy – Low Carbon Buildings CI/Sfb Fourth Issue June 2011 (2–) Rn7 M2 INSULATION FOR ROOFS, WALLS & FLOORS Product Selector Visit our brand new website: www.kingspaninsulation.co.uk

Upload: others

Post on 04-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Insulation

Low Energy –Low Carbon Buildings

CI/Sfb

Fourth Issue June 2011

(2–) Rn7 M2

INSULATION FOR ROOFS, WALLS & FLOORS

Product Selector

Visit our

brandnewwebsite:

www.k

ingspanins

ulatio

n.co.u

k

Page 2: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

2

Kingspan Insulation Ltd reserves the right to amend product specifications without prior notice.The information contained in the document is given in good faith and applies to the usesdescribed. Recommendations for use should be verified as to the suitability and compliance withactual requirements, specifications and any applicable laws and regulations. Kingspan Insulationrecommend using the Technical Advice service (see back cover).

Page 3: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

BreathableM

embranes

CavityClosers

FloorInsulation

WallInsulation

RoofInsulation

3

ContentsPage

Product Selector Chart 4

U–value Time Saver 6

Building Regulations and Standards 7

Roof Insulation 9Kooltherm® K7 Pitched Roof Board 10Thermapitch® TP10 11Thermaroof® TR21 12Thermaroof® TR25 13Thermaroof® TR26 LPC/FM 14Thermaroof® TR27 LPC/FM 15Thermaroof® TR31 16Thermataper® TT46 LPC/FM 17Thermataper® TT47 LPC/FM 18Kooltherm® K11 Roofboard 19Styrozone® N 300 R 20Styrozone® H 350 R 21Styrozone® N 500 R 22Styrozone® N 700 R 23

Wall Insulation 25Kooltherm® K5 External Wall Board 26Kooltherm® K8 Cavity Board 27Kooltherm® K12 Framing Board 28Kooltherm® K15 Rainscreen Board 29Kooltherm® K17 Insulated Plasterboard 30Kooltherm® K18 Insulated Plasterboard 31Thermawall® TW50 32Thermawall® TW55 33Styrozone® N 300 R 20Styrozone® H 350 R 21

Floor Insulation 35Kooltherm® K3 Floorboard 36Kooltherm® K10 FM Soffit Board 37Thermafloor® TF70 38Thermafloor® TF73 39Styrozone® N 300 R 20Styrozone® H 350 R 21Styrozone® N 500 R 22Styrozone® N 700 R 23

Cavity Closers 41Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS 42Thermabate® & Thermabate® PLUS 44

Breathable Membranes 46nilvent® 47

Page 4: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Product Selector

Roof Insulation

Kooltherm®K7PitchedRoofBoard

Thermapitch®TP10

Thermaroof®TR21

Thermaroof®TR25

Thermaroof®TR26LPC/FM

Thermaroof®TR27LPC/FM

Thermaroof®TR31

Thermataper®TT46LPC/FM

Thermataper®TT47LPC/FM

Kooltherm®K11RoofBoard

Styrozone

®N300R

Styrozone

®H350R

Styrozone

®N500R

Styrozone

®N700R

nilvent®

Pitched Roof Insulation

Over / between / underrafter sarking

� �

Breathable membrane �

Flat Roof Insulation

Tapered Roofing System � �

Under partially bondedbuilt–up felt

� � � �

Under cold liquid appliedwaterproofing

� � �

Under mastic asphalt � �

Directly over timber joists �

Under torch–on feltwaterproofing

Under mechanically–fixed,single–ply non–bituminousmembranes

� � � �

Under fully adheredsingly–ply membranes

� �

In LPCB/FM approvedconstructions

� � � �

Protected Membrane Roofs

Traditionally protectedmembrane / Roof gardens

� �

Car park decks � � � �

Lightweight protected membrane/ maintenance access

� �

Green Roofs

Insulation suitable for useunder Green Roofs

� � � � � �

4

Page 5: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Kooltherm®K5ExternalwallBoard

Kooltherm®K8CavityBoard

Kooltherm®K12FramingBoard

Kooltherm®K15RainscreenBoard

Kooltherm®K17InsulatedPlasterboard

Kooltherm®K18InsulatedPlasterboard

Thermawall®TW

50

Thermawall®TW

55

Styrozone

®N300R

Styrozone

®H350R

nilvent®

Kooltherm®CavityCloser&

Kooltherm®CavityCloserPLUS

Thermabate®&Thermabate®PLUS

Product Selector

Wall Insulation

Floor Insulation

5

Kooltherm®K3Floorboard

Kooltherm®K10FM

SoffitBoard

Thermafloor

®TF70

Thermafloor

®TF73

Styrozone

®N300R

Styrozone

®H350R

Styrozone

®N500R

Styrozone

®N700R

Solid ground floors � �

Suspended ground floors � �

Floating ground floors � �

Soffit lining �

Heavy duty / industrial / cold store floors � � � �

Partial fill cavity walls � �

Internal dry–lining � �

Insulated render systems �

Rainscreen cladding systems �

Timber frame � �

Steel frame � �

Basement walls � �

Cavity Closers � �

Breathable membrane �

Page 6: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

6

U–value Time SaverHelp us to help you when requesting U–values from KingspanInsulation’s Technical Advice Service. Please provide thefollowing information for all building elements:• What U–value is required?• Project address and postcode• Type of building eg. Offices.

Flat Roof• What is the type of waterproofing being used?• What is the roof substrate – timber, concrete or profiled metal deck?• Is there a ceiling – if yes then is it plasterboard or suspended tile?• If using Kingspan Thermaroof® TR31 what are the joist size centres?• If mechanical fixings are being used – what are they (carbon steel, galvanised steel,

stainless steel or telescopic fixings)?

Pitched Roof• What are the size and centres of the rafters or ceiling joists?• Is the insulation at ceiling or rafter level?• If at rafter level, is there a 50 mm ventilated airspace between the rafters above the insulation?• If no 50 mm ventilated airspace, is there a breathable membrane above the rafters?• If a breathable membrane is being used is it above or below the counter batten or draped into the rafter void?

Wall Construction• What is the wall construction – cavity, solid wall, rendered?• If cavity wall construction, what is the manufacturer and type of block being used for inner

(and outer if applicable) leaf or its thermal conductivity (may also be known as λ–value?)• What is the internal wall finish?• Is the wall above ground or basement wall?

Ground Floor• What is the perimeter / area ratio? (This is the length of the externally exposed floor slab perimeter measured

on the inside wall, not including internal or separating walls, divided by the floor area.)• Is the floor a solid ground bearing slab, suspended beam & block or suspended timber or concrete floor

(if suspended timber the joist size and centres are required.)

Floor Other Than Ground• Is soffit insulation required?• If the insulation is to be fitted between joists what are the joist size and centres?

Technical AdviceTelephone: 01544 387 382 Fax: 01544 387 482 Email: [email protected]

Page 7: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

7

Building Regulations and Standards

New Buildings Existing BuildingsBest Starting Point Extension, Conversion and

Renovation Of All BuildingsDwellings Buildings Other New Elements Refurbishment /

Than Dwellings Retained ElementsLofts 0.13 0.14 0.16 0.16All other roofs 0.13 0.14 0.18 0.18Walls 0.18 0.22 0.28 0.30Floors 0.13 0.18 0.22 0.25

* There are specific exceptions relating to, e.g. conversion of heated buildings and infilling of openings. Please consult the Technical Handbooks.Column B applies where the existing building has, or will be improved to have, wall U–values better than 0.7 W/m2.K and roof U–values betterthan 0.25 W/m2.K. If the U–values are worse, then column A applies.

New Buildings Existing BuildingsDomestic Non– Extension, Conversion &

Domestic Renovation – Most Works*Notional Best Domestic Domestic Domestic Non–Building Starting New New Altered / Domestic

Point Elements Elements RefurbishedA* B* Elements

Lofts 0.13 0.13 0.13 0.15 0.15 0.15All other roofs 0.13 0.13 0.15 0.18 0.18 0.15Walls 0.19 0.22 0.19 0.22 0.22 0.25Floors 0.15 0.18 0.15 0.18 0.18 0.20

England and WalesNew Buildings (ADL 1A & ADL 2A)The main requirement of Approved Documents L1A and L2A is that buildings meet a defined CO2 emissions target. The roof, wall andfloor U–values required to meet this target will depend on the design of the building, orientation, heating system etc. To ease theprocess, Kingspan Insulation has undertaken analysis to give the ‘best starting point’ U–values, for specifiers to work from in gettingtheir designs to comply. They will be almost exactly what is required for some buildings and short of what is required for others.These ‘best starting point’ U–values are shown below.

Existing Buildings (ADL 1B & ADL 2B)Approved Documents L1B and L2B give specific U–value requirements for newly constructed elements and retained / refurbishedelements. They apply to all works, regardless of whether the works relate to an extension, conversion or renovation.These required U–values are shown below.

ScotlandNew Buildings (Section 6 – Energy)The main requirement of Technical Handbooks Sections 6 is that buildings meet a defined CO2 emissions target. For domestic, thistarget is generated by a set of 2010 notional buildings, which also offer a simplified elemental approach to compliance. If a building isconstructed in accordance with the parameter values that define the notional building, then it will automatically comply with the CO2

emissions target. The ‘notional’ U–values for roofs, walls and floors are shown opposite. For non–domestic, the approach is the sameas that described overleaf for ADL2A and ‘best starting point’ U–values are shown below.

Existing Buildings (Section 6 – Energy)Technical Handbooks Sections 6 give specific area–weighted average U–value requirements for newly constructed elements and altered/ refurbished elements. They apply to most works*, regardless of whether the works relate to an extension, renovation, or conversione.g. of a whole unheated building, loft or garage. For existing dwellings, there are differing requirements for newly constructedelements, depending upon the thermal efficiency of the existing building*. The required U–values are shown below.

Page 8: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

8

Kingspan Kooltherm® K7 Pitched Roof Board

Page 9: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

RoofInsulation

Roof Insulation

Page 10: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

10

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

INSULATION FOR TILED OR SLATED PITCHEDWARM ROOF SPACES

Recommended for:

� New build� Re–roofing� Loft conversion� Unventilated pitched roofs – between rafters� Unventilated pitched roofs –

between and over rafters� Ventilated pitched roofs –

between rafters

K7 Pitched Roof Board

Product Data

Kingspan Kooltherm® K7Pitched Roof Board

Kingspan Kooltherm® K18Insulated Plasterboard

Kingspan nilvent®

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Composite foilCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 25 – 140 mmComplementary Products � nilvent® (page 47)

� Kooltherm® K18 Insulated Plasterboard (page 31)

RoofInsulation

Page 11: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

11

RoofInsulation

INSULATION FOR TILED OR SLATED PITCHEDWARM ROOF SPACES

Recommended for:

� New build� Re–roofing� Loft conversion� Unventilated pitched roofs – between rafters� Unventilated pitched roofs –

between and over rafters� Ventilated pitched roofs –

between rafters

TP10

Product Data

Kingspan Thermapitch® TP10

Kingspan Kooltherm® K18Insulated Plasterboard

Kingspan nilvent®

Thermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products � nilvent® (page 47)

� Kooltherm® K18 Insulated Plasterboard (page 31)

Page 12: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

12

INSULATION FOR FLAT ROOFS WATERPROOFED WITHPARTIALLY BONDED BUILT–UP FELT AND MASTIC ASPHALT

Recommended for:

� New build� Refurbishment� Metal, concrete or timber decks

Product Data

Kingspan Thermaroof® TR21

Kingspan Kooltherm® K8 Cavity Board

Thermal Conductivity 0.027 W/m.K (insulant thickness < 80 mm)0.026 W/m.K (insulant thickness 80 – 119 mm)0.025 W/m.K (insulant thickness ≥ 120 mm)

Facings Glass reinforced perforated celluloseCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.6 mThicknesses Available 30 – 120 mmComplementary Products

TR21RoofInsulation

Page 13: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

13

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

INSULATION FOR FLAT ROOFS WATERPROOFED WITH COLDLIQUID APPLIED WATERPROOFING

Recommended for:

� Fast–track building programmes� New build� Refurbishment� Metal, concrete or timber decks

TR25

Product DataThermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)

0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120mm)

Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.6 mThicknesses Available 50 – 120 mmComplementary Products

RoofInsulation

Kingspan Kooltherm® K8 Cavity Board

Kingspan Thermaroof® TR25

Page 14: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

14

TR26 LPC/FM

LPS 1181: Part 1Certificate No. 388b/01

Class 1 RoofConstruction

INSULATION FOR FLAT ROOFS WATERPROOFED WITHMECHANICALLY FIXED SINGLE–PLY WATERPROOFING

Recommended for:

� LPCB / FM compliance� Fast–track building programmes� New build� Refurbishment� Metal, concrete or timber decks

Product Data

Kingspan Thermaroof® TR26

Kingspan Kooltherm® K8 Cavity Board

Thermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 25 – 150 mmComplementary Products � Thermataper® TT46 LPC/FM (page 17)

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

RoofInsulation

Page 15: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLYADHERED SINGLE–PLY, PARTIALLY BONDED BUILT–UP FELT,MASTIC ASPHALT AND COLD LIQUID APPLIED WATERPROOFING

Recommended for:

� LPCB / FM compliance� Fast–track building programmes� New build� Refurbishment� Metal, concrete or timber decks

TR27 LPC/FM

LPS 1181: Part 1Certificate No. 388b/01

Class 1 RoofConstruction

Kingspan Kooltherm® K8 Cavity Board

Kingspan Thermaroof® TR27

Product DataThermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)

0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120mm)

Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.6 m and 1.2 x 2.4 mThicknesses Available 25 – 130 mm (1.2 x 0.6 m boards) and 50 – 145 mm (1.2 x 2.4 m boards)Complementary Products � Thermataper® TT47 LPC/FM (page 18)

15

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

RoofInsulation

Page 16: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

16

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

STRUCTURAL INSULATION / FSC CERTIFIED PLYWOODCOMPOSITE FOR FLAT ROOFS WATERPROOFED WITHPARTIALLY BONDED BUILT–UP FELT

Recommended for:

� New build� Refurbishment� Directly over timber decks

Product Data

Kingspan Thermaroof® TR31

Kingspan Kooltherm® K8 Cavity Board

Kingspan Kooltherm® K7 Pitched Roof Board

Thermal Conductivity 0.022 W/m.K (insulant)0.140 W/m.K (plywood)

Upper Facing FSC certified 6 mm WBP exterior grade plywoodCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Lower Facing Composite foilBoard Size 1.2 x 2.4 mThicknesses Available 50 – 120 mm (Insulation thickness only)Complementary Products

TR31RoofInsulation

Page 17: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

17

RoofInsulation

TT46 LPC/FM

Product Data

Kingspan Thermataper® TT46 LPC/FM

Kingspan Kooltherm® K8 Cavity Board

Thermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mManufactured Rate of Fall 1:30; 1:40; 1:60; 1:80Complementary Products � Thermaroof® TR26 LPC/FM (page 14)

TAPERED INSULATION FOR FLAT ROOFS WATERPROOFED WITHMECHANICALLY FIXED SINGLE–PLY WATERPROOFING

Recommended for:

� Alternative to expensive screed–to falls roofs� Reducing load–bearing implications

for new or existing structures� Fast–track building programmes� New build� Refurbishment� Metal, concrete or timber decks

LPS 1181: Part 1Certificate No. 388b/01

Class 1 RoofConstruction

Page 18: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

18

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

TT47 LPC/FM

Product Data

Kingspan Thermataper® TT47 LPC/FM

Kingspan Kooltherm® K8 Cavity Board

Thermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120 mm)

Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.6 m and 1.2 x 2.4 mManufactured Rate of Fall 1:30; 1:40; 1:60; 1:80Complementary Products � Thermaroof® TR27 LPC/FM (page 15)

TAPERED INSULATION FOR FLAT ROOFS WATERPROOFED WITHFULLY ADHERED SINGLE–PLY, PARTIALLY BONDED BUILT–UP FELT,MASTIC ASPHALT AND COLD LIQUID APPLIED WATERPROOFING

Recommended for:

� Alternative to expensive screed–to falls roofs� Reducing load–bearing implications

for new or existing structures� Fast–track building programmes� New build� Refurbishment� Metal, concrete or timber decks

LPS 1181: Part 1Certificate No. 388b/01

Class 1 RoofConstruction

RoofInsulation

Page 19: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

19

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

RoofInsulation

K11 Roofboard

Product Data

Kingspan Kooltherm® K8 Cavity Board

Kingspan Kooltherm® K11 Roof Board

Thermal Conductivity 0.023 W/m.K (insulant thickness 25 – 44 mm)0.021 W/m.K (insulant thickness ≥ 45 mm)0.050 W/m.K (perlite)

Upper Facing 20 mm bitumen coated perliteCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Lower Facing Glass tissueBoard Size 1.2 x 1.0 mThicknesses Available 40 and 70 mm (Insulation thickness only)Complementary Products

INSULATION FOR FLAT ROOFS WATERPROOFED WITHFULLY BONDED TORCH APPLIED MULTI–LAYERBITUMINOUS WATERPROOFING

Recommended for:

� New build� Refurbishment� Metal, concrete or timber decks

Page 20: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

20

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

N 300 R

Product Data

Kingspan Kooltherm® K8 Cavity Board

Kingspan Styrozone® N 300 R

Thermal Conductivity 0.035 W/m.K (insulant thickness < 80 mm)0.037 W/m.K (insulant thickness 80 mm)0.038 W/m.K (insulant thickness 100 − 160 mm)0.040 W/m.K (insulant thickness > 160 mm)

Core High performance rigid extruded polystyrene insulant manufactured with a blowing agentthat has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)

Board Size 1.25 x 0.6 mThicknesses Available 30 – 180 mmComplementary Products � Styrozone® H 350 R (page 21)

INSULATION FOR INVERTED ROOFS, BASEMENTS, CAR PARKDECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL ANDCOLD STORE FLOORING

Recommended for:

� New build� Refurbishment� Inverted / protected

membrane roofs� Basement walls� Below floor slab or screed

RoofInsulation

Page 21: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

21

RoofInsulation

Product Data

Kingspan Kooltherm® K8 Cavity Board

Kingspan Styrozone® H 350 R

Thermal Conductivity 0.029 W/m.K (insulant thickness ≤ 120 mm)0.031 W/m.K (insulant thickness > 120 mm)

Core High performance rigid extruded polystyrene insulant manufactured with a blowing agentthat has zero Ozone Depletion Potential (ODP)

Board Size 1.25 x 0.6 mThicknesses Available 30 – 160 mmComplementary Products � Styrozone® N 300 R (page 20)

INSULATION FOR INVERTED ROOFS, BASEMENTS, CAR PARKDECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL ANDCOLD STORE FLOORING

Recommended for:

� New build� Refurbishment� Inverted / protected membrane roofs� Basement walls� Below floor slab or screed

H 350 R

Page 22: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

22

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

N 500 R

Product Data

Kingspan Styrozone® N 500 R

Thermal Conductivity 0.036 W/m.K (insulant thickness ≤ 70 mm)0.038 W/m.K (insulant thickness > 70 mm)

Core High performance rigid extruded polystyrene insulant manufactured with a blowing agentthat has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)

Board Size 1.25 x 0.6 mThicknesses Available 30 – 120 mmComplementary Products � Styrozone® N 300 R (page 20)

� Styrozone® H 350 R (page 21)� Styrozone® N 700 R (page 23)

INSULATION FOR CAR PARK DECKS, AND HEAVY DUTYCOMMERCIAL, INDUSTRIAL AND COLD STORE FLOORING

Recommended for:

� New build� Refurbishment� Inverted / protected membrane roofs� Below floor slab or screed

RoofInsulation

Page 23: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

23

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

RoofInsulation

Product Data

Kingspan Styrozone® N 700 R

Thermal Conductivity 0.036 W/m.K (insulation thickness ≤ 50 mm)Core High performance rigid extruded polystyrene insulant manufactured with a blowing agent

that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.25 x 0.6 mThicknesses Available 50 mmComplementary Products � Styrozone® N 500 R (page 22)

INSULATION FOR CAR PARK DECKS, ANDHEAVY DUTY COMMERCIAL, INDUSTRIALAND COLD STORE FLOORING

Recommended for:

� New build� Refurbishment� Inverted / protected membrane roofs� Below floor slab or screed

N 700 R

Page 24: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Kingspan Kooltherm® K8 Cavity Board24

Page 25: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

WallInsulation

Wall Insulation

Page 26: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

26

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K5 External Wall Board

Product Data

Kingspan Kooltherm® K5 External Wall Board

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Glass tissueCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.6 mThicknesses Available 20 – 100 mmComplementary Products

EXTERNAL INSULATION FOR MASONRY WALLS

Recommended for:

� Solid walled buildings� Transforming and upgrading

the appearance ofexisting buildings

� New build� Refurbishment� Insulated render system

on masonry

WallInsulation

Page 27: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

27

K8 Cavity Board

Product Data

Kingspan Kooltherm® K8 Cavity Board

Kingspan Kooltherm® K3 Floorboard

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Composite foilCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.45 mThicknesses Available 20 – 120 mmComplementary Products � Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page 42)

� Thermabate® and Thermabate® PLUS Cavity Closer (page 44)

PARTIAL FILL CAVITY WALL INSULATION

Recommended for:

� Traditional cavity wall construction methods� New build� All brick and block types

WallInsulation

Page 28: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

28

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K12 Framing Board

Product Data

Kingspan Kooltherm® K12 Framing Board

Kingspan Kooltherm® K18 Insulated Plasterboard

Kingspan nilvent®

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Composite foilCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 25 – 140 mmComplementary Products � nilvent® (page 47)

� Kooltherm® K18 Insulated Plasterboard (page 31)

INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS

Recommended for:

� Insulating between studs� Insulating sheathing� Steel frame walls� Timber clad / tile hung

timber frame wallsWallInsulation

Page 29: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

29

K15 Rainscreen Board

Product Data

Kingspan Kooltherm® K15 Rainscreen Board

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Composite foilCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 25 – 130 mmComplementary Products

INSULATION FOR RAINSCREEN CLADDING SYSTEMS

Recommended for:

� Proprietary and non–proprietaryexternal finishes

� Insulated rainscreencladding systems onboth masonry andsteel frames

� New build� Refurbishment

WallInsulation

Kingspan Kooltherm® K15 Rainscreen Board is also available with a black foil face.

Page 30: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

30

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K17 Insulated PlasterboardINSULATED PLASTERBOARD FOR PLASTER DAB /ADHESIVE BONDED DRY–LINING

Recommended for:

� Traditional cavity walls� Solid rendered walls� Insulation and dry–lining

applications� New build� Refurbishment

Kingspan Kooltherm® K17 Insulated Plasterboard

Kingspan Kooltherm® K8 Cavity Board

Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)

0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)0.190 W/m.K (plasterboard)

Front Facing 12.5 mm plasterboardCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Reverse Facing Glass tissueBoard Size 1.2 x 2.4 mThicknesses Available 20 – 100 mm (Insulation thickness only)Complementary Products � Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page 42)

� Thermabate® and Thermabate® PLUS Cavity Closer (page 44)� Kooltherm® K18 Insulated Plasterboard (page 31)

WallInsulation

Page 31: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

31

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K18 Insulated Plasterboard

Product Data

Kingspan Kooltherm® K18 Insulated Plasterboard

Thermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)0.190 W/m.K (plasterboard)

Front Facing 12.5 mm plasterboardCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Reverse Facing Composite foilBoard Size 1.2 x 2.4 mThicknesses Available 20 – 100 mm (Insulation thickness only)Complementary Products � Kooltherm® K12 Framing Board (page 28)

� Kooltherm® K7 Pitched Roofing Board (page 10)� Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page 42)� Thermabate® and Thermabate® PLUS Cavity Closer (page 44)� Kooltherm® K17 Insulated Plasterboard (page 30)

INSULATED PLASTERBOARD FOR MECHANICALLYFIXED DRY–LINING

Recommended for:

� Solid walls� Timber frame walls� Timber rafters� Metal furring systems� Insulation, dry–lining and

vapour control applications� New build� Refurbishment� Loft conversions

WallInsulation

Page 32: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

TW50PARTIAL FILL CAVITY WALL INSULATION

Recommended for:

� Traditional cavity wall construction methods� New build� All brick and block types

Kingspan Thermawall® TW50

Product DataThermal Conductivity 0.022 W/m.KFacings Composite FoilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 0.45 mThicknesses Available 20 – 100 mmComplementary Products � Thermabate® and Thermabate® PLUS Cavity Closer (page 44)

� Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page 42)� Kooltherm® K8 Cavity Board (page 27)

32

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

WallInsulation

Page 33: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

TW55INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS

Recommended for:

� Insulating between studs� Insulating sheathing� Steel frame walls� Timber clad / tile hung

timber frame walls

Kingspan Thermawall® TW55

Kingspan nilvent®

Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products � Kooltherm® K18 Insulated Plasterboard (page 31)

� nilvent® (page 47)� Kooltherm® K12 Framing Board (page 28)

33

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

WallInsulation

Kingspan Kooltherm® K18 Insulated Plasterboard

Page 34: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Kingspan Kooltherm® K3 Floorboard34

Page 35: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

FloorInsulation

Floor Insulation

Page 36: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

36

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K3 FloorboardINSULATION FOR FLOORS

Recommended for:

� Below the floor slab / screed� Beam and block floors� Suspended timber floors� Underfloor heating applications� Floor perimeter insulation� New build� Refurbishment

Kingspan Kooltherm® K3 Floorboard

Kingspan Kooltherm® K8 Cavity Board

Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)

0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Facings Glass tissueCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 25 – 140 mmComplementary Products

FloorInsulation

Page 37: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

37

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

K10 FM Soffit BoardINSULATION FOR STRUCTURAL CEILINGS (SOFFITS)

Recommended for:

� Insulating under structural ceilings� Car park ceilings

Kingspan Kooltherm® K10 Soffit Board

Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)

0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)

Upper Facing Glass tissueCore Premium performance rigid thermoset modified resin insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Exposed Facing Composite foilBoard Size 1.2 x 2.4 mThicknesses Available 25 – 140 mmComplementary Products

FloorInsulation

Page 38: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

TF70INSULATION FOR SOLID CONCRETE AND SUSPENDEDGROUND FLOORS

Recommended for:

� Below the floor slab / screed� Beam and block floors� Domestic floating floors� Suspended timber floors� Underfloor heating applications� Floor perimeter insulation� New build� Refurbishment

Kingspan Thermafloor® TF70

Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant manufactured with

a blowing agent that has zero Ozone Depletion Potential (ODP) and low GlobalWarming Potential (GWP)

Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products

38

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

Kingspan Kooltherm® K8 Cavity Board

FloorInsulation

Page 39: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

TF73INSULATION FOR FLOATING AND SUSPENDED GROUND FLOORS

Recommended for:

� Solid floating ground floors� Beam and block floors� Suspended timber floors� Areas where high compressive

strength required� New build� Refurbishment

Kingspan Thermafloor® TF73

Kingspan Kooltherm® K8 Cavity Board

Product DataThermal Conductivity 0.029 W/m.K (insulant thickness 20 – 70 mm)

0.030 W/m.K (insulant thickness 70 – 120 mm)0.150 W/m.K (chipboard)

Upper Facing FSC certified 18 mm T&G chipboardCore High performance rigid extruded polystyrene insulant manufactured with a blowing

agent that has zero Ozone Depletion Potential (ODP)Board Size 2.4 x 0.6 mThicknesses Available 25 – 80 mm (Insulation thickness only)Complementary Products

39

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

FloorInsulation

Page 40: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Kingspan Kooltherm® K18 Insulated Plasterboard40

Page 41: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Cavity Closers

CavityClosers

Page 42: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

42

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

FOR CLOSING CAVITIES AROUND OPENINGS IN MASONRY WALLS

Recommended for:

� Traditional cavity wall construction� Window and door cavities� Use with PVCu and

wooden frames� Simplified construction� Cavity widths up to 305 mm� Using as a frame former

(Kooltherm® Cavity CloserPLUS only)

Kingspan Kooltherm® K8 Cavity Board

Kingspan Kooltherm® Cavity Closer

Product DataThermal Conductivity 0.022 W/m.KSheathing PVC–U extrusionCore Premium performance rigid thermoset modified resin insulant manufactured with a

blowing agent that has zero Ozone Depletion Potential (ODP) and low Global WarmingPotential (GWP)

Length 2.4 mWidths Available 50 – 150 mm (or combinations up to 305 mm)Complementary Products � Kooltherm® K8 Cavity Board (page 27)

� Thermawall® TW50 (page 32)� Kooltherm® K17 Insulated Plasterboard (page 30)� Kooltherm® K18 Insulated Plasterboard (page 31)

CavityClosers

Cavity Closer

Page 43: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

CavityClosers

Kingspan Kooltherm® Cavity Closer 50For cavities 50 – 74 mm wide

Kingspan Kooltherm® Cavity Closer 75For cavities 75 – 99 mm wide

Kingspan Kooltherm® Cavity Closer 100For cavities 100 – 109 mm wide

Kingspan Kooltherm® Cavity Closer 110For cavities 110 – 124 mm wide

Kingspan Kooltherm® Cavity Closer 125For cavities 125 – 149 mm wide

Kingspan Kooltherm® Cavity Closer 150For cavities 150 – 155 mm wide

43

6

31.5

50

48

128

6

31.5

110

48

170

6

31.5

125

48

170

6

31.5

150

48

170

6

31.5

75

48

128

6

31.5

100

48

128

Cavity CloserPRE–FORMED TO SPECIFIED OPENING SIZES FOR CLOSINGCAVITIES IN PLASTIC, TIMBER, OR METAL WINDOW FRAMESAND AN INSULATED LINTEL

Page 44: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

FOR CLOSING CAVITIES AROUND OPENINGS IN MASONRY WALLS

Recommended for:

� Traditional cavity wall construction� Window and door cavities� Use with PVCu and

wooden frames� Simplified construction� Cavity widths up to 200 mm� Using as a frame former

(Thermabate PLUS only)

Kingspan Kooltherm® K8 Cavity Board

Kingspan Thermabate®

Product DataThermal Conductivity 0.034 W/m.KSheathing PVC–U extrusionCore High performance rigid thermoset urethane insulantLength 3.0 mWidths Available 50 – 100 mm*Complementary Products � Kooltherm® K8 Cavity Board (page 27)

� Thermawall® TW50 (page 32)� Kooltherm® K17 Insulated Plasterboard (page 30)� Kooltherm® K18 Insulated Plasterboard (page 31)

44

*Sections can be joined together to suit cavity widths up to 200 mm.

CavityClosers

Page 45: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

45

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

Thermabate® 50(Brown)

Thermabate® 65(Black)

Thermabate® 75(White)

Thermabate® 85(Yellow)

Thermabate® 90(Orange)

Thermabate® 100(Green)

CavityClosers

PRE–FORMED TO SPECIFIED OPENING SIZES FOR CLOSINGCAVITIES IN PLASTIC, TIMBER, OR METAL WINDOW FRAMES ANDAN INSULATED LINTEL

Page 46: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

BreathableM

embranes

Breathable Membranes

Page 47: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

Visit www.kingspaninsulation.co.uk to download the full product brochure,order samples and learn about case studies

47

BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFSAND TIMBER FRAME WALLSRecommended for:

� All types of pitched roofing� Timber framing� Under battens or directly

on sarking boards� New build� Re–roofing

Kingspan nilvent®

Product DataWater Vapour Resistance 0.17 MN.s/gLiquid Water Penetration > 2 mTensile Strength 233 N longitudinal

162 N transverseRoll Length 50 mRoll Width 1.5 mThickness 0.5 mmArea Per Roll 75 m2

Complementary Products � Kooltherm® K7 Pitched Roof Board (page 10)� Kooltherm® K12 Framing Board (page 28)� Thermapitch® TP10 (page 11)� Thermawall® TW55 (page 33)

BreathableM

embranes

Page 48: Product Selector - Just Insulation · Thermaroof ® TR26 LPC/FM 14 Thermaroof ® TR27 LPC/FM 15 The rma of ® R3 16 Thermataper ® TT46 LPC/FM 17 Thermataper ® TT47 LPC/FM 18 Kooltherm

General EnquiriesTel: +44 (0) 1544 388 601Fax: +44 (0) 1544 388 888

email: [email protected]

Technical AdviceTel: +44 (0) 1544 387 382Fax: +44 (0) 1544 387 482

email: [email protected]

Tapered RoofingTel: +44 (0) 1544 387 383Fax: +44 (0) 1544 387 483

email: [email protected]

Literature and SamplesTel: +44 (0) 1544 387 384Fax: +44 (0) 1544 387 484

email: [email protected]: www.kingspaninsulation.co.uk/literature

Customer ServiceTel: +44 (0) 1544 388 601Fax: +44 (0) 1544 388 888

email: [email protected]

® Kingspan, Kooltherm, nilvent, Styrozone, Thermafloor, Thermaroof, Thermawall, Thermapitch, Thermataper,the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in the UK Ireland and other countries. All rights reserved.

Kingspan Insulation Ltd. Registered in England & Wales, No. 01882722. Registered Office: Pembridge, Leominster, Herefordshire HR6 9LA UK.

Kingspan Insulation LtdPembridge, Leominster, Herefordshire HR6 9LA, UK

www.kingspaninsulation.co.uk