reliable and precise fabric tension measurementsuitable for any kind of installation and all operating conditionscompletely maintenance free
Your benefits:
-
For more information please contact:
Load range from 10 kN to 100 kN Compensating bearing design ensures measurement accuracy Measures the force on one side of a fixed roll Safety bolt to avoid damage during transportation and roll change Shear force transducer with 10m of sealed connecting cable 6-wire technology with sensing line to detect cable faults
Load Cell F-1008, F-1009
F-1008 with bearing yoke for cylinder bearing
Type F-1008AN F-1008BN F-1008CN
max. rated load [kN] 30 50 100
max. bearing yoke diameter [mm] 220 330 410
Overall dimensions L x W x H [mm] 482 x 150 x 422 600 x 200 x 515 870 x 250 x 745
Material Mild steel (cast iron) Stainless steel 316L
Shear force transducerwith encapsulated cable
Type F-1009AN F-1009BN F-1009CN LC-100AH LC-100BH
max. rated load [mm] 30 60 100 40 50
max. dimensions of pillow
block foot plate[mm] 340 x 170 470 x 206 600 x 280 280 x 150 410 x 150
Overall dimensions L x W x H [mm] 450 x 250 x 450 620 x 290 x 620 880 x 150 x 750 280 x 150 x 100 410 x 150 x 110
Load Cell with bearing yoke
F-1009 with mountingplate for pillow block
Load Cell LC-100 Measures horizontal forces Suitable to be integrated into tensioner design
Load Cell LC-100 for pillow block
Material Stainless steel
Bridge Amplifier Card Amplifier Card F-1017M converts the output signal from the Load Cell
into a mA signal (4-20mA) corresponding to the actual felt-/wire tension Specific tension value in N/mm or PLI available as analog signal or as
digital signal for Profibus DP applications (12 Mbps) Signal monitoring with alarm and warning message History recording Zeroing of roll weight at the press of a button JUD Field Communication Software FCS-1017 or JUD Operator Panel OP-
1017 can be used for configuration OP-1017 allows the storage of up to 24 configuration files
Load Cell for pillow block
Load CellsLoad Cells mounted on one side of the measuring roll allow for precise measurement of the felt/wire tension. JUD Load Cells are available in a series of proven designs (with bearing yoke for bearing housing or with a support plate for pillow block installation) for nominal loads from 10 to 100 kN both in mild steel/cast iron or all stainless steel V4A/316L. The Load Cell measures the force applied by the felt/wire tension on one side of a roll with constant wrap angles. Also in tough operating conditions up to 140C you can rely on the JUD Load Cells.
Amplifier Card F-1017M
F-1009C stainless steel version
www.ibs-ppg.com
Product Manager Matthias Dornstetter JUD AG Papiermaschinen Phone +423 375 8263 [email protected]