product specs central heating module - asset · chm2100-240eu 051116 product specs central heating...

7
CHM2100-180EU 051116 Central Heating Module CHM2100-180EU Product Specs Features Diesel / light oil fired system with a single stage burner Temperature control and fuel usage is automatic. includes unique “Climate Control” system which ensures efficient and reliable burner operation in all conditions Compact and portable design for easy positioning on the work site. All system operation is controlled and monitored from the central heating module control panel 8-light system operation feature for easy system troubleshooting. Fluid circulation system is low pressure and atmospherically vented. There is no chance of an explosion or line burst due to pressure build-up. No special boiler certification is required to operate the system. Quick-connect hose couplers , “no- drain” fluid lines and a “rapid air elimination” feature ensures quick setup-and-go operation. Conforms to most special job requirements due to its modular nature. Burner .......................................Single stage ..............................................Diesel fuel/#1 or 2 heating oil Input capacity ........................182 KW Output capacity .....................149 KW Fuel consumption ..................16.8 LPH, 14.3 KG/H Weight .......................................Dry - 680 KG, Wet - 1,225 KG Electrical ...................................Single phase, 230 V, 50 Hz, 20 Amps Loading - standard ....................Forklift pockets, 4-point sling lift Heat exchanger ........................Water jacket / fire tube type ..............................................Fluid volume - 94.6 L ..............................................Fluid temp. range - 49°C to 93°C Fuel tank ...................................Welded steel ..............................................Fuel capacity - 492 L ..............................................29.3 hr operating range at full output Climate control system .............Maintains optimum burner reliability and effiiciency at a full range of ambient temperature conditions. Assures system start-up and operation in all conditions. “Before system start-up” ....Pre-heater .........................4000 Watt electric circulation heater, 240V, Preheats heat exchanger glycol before system start-up. “During system operation” ....Fuel heater........................Automatically maintains set fuel temperature. Fluid (hot glycol)-to-fluid (fuel) heat transfer. ....Combustion air heater ......Automatically maintains set combustion air temperature. Fluid (hot glycol)-to-air heat transfer utilizing a heat transfer coil. Control & monitoring .................Pump & temperature controls. ..............................................Full gauge panel showing circulation fluid temperatures & pressures, fuel pressures. ..............................................8-light system operation feature for easy system troubleshooting. Internal fluid circulation system Basic features .......................Atmospherically vented, low pressure. ..............................................Single supply & return. ..............................................Adjustable fluid temperature control. ..............................................Auto pressure by-pass for pump protection and variable flow demands. ..............................................Auto temperature bypass for heat exchanger protection. Circulation pump ...................2900 RPM, 1-1/2 HP., 1.1KW ..............................................Flow - 11.34 M³/HR @ 21 M W.C. Primary circulation.................Fluid circulation lines - 40 MM ..............................................Ball valves - 40 MM ..............................................Kamlock quick couplers - 40 MM Heat transfer fluid (HTF) .......Non-toxic propylene glycol / water mixture. ..............................................Freeze protected. Lock-out.................................locks out primary “supply” & “return” fluid circulation valves and control panel Optional Transport trailer Generator ..............................Diesel Specifications 162.5 cm 122 cm 211 cm 186 cm Please note: The black metal frame shown above does not feature on the units for sale.

Upload: others

Post on 21-Aug-2020

3 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil

CHM2100-180EU 051116

Central Heating ModuleCHM2100-180EU

Product Specs

Features• Diesel / light oil fired system with a

single stage burner• Temperature control and fuel usage

is automatic.• includes unique “Climate Control”

system which ensures efficient andreliable burner operation in allconditions

• Compact and portable design foreasy positioning on the work site.

• All system operation is controlledand monitored from the centralheating module control panel

• 8-light system operation feature foreasy system troubleshooting.

• Fluid circulation system is lowpressure and atmosphericallyvented. There is no chance of anexplosion or line burst due topressure build-up. No special boilercertification is required to operatethe system.

• Quick-connect hose couplers , “no-drain” fluid lines and a “rapid airelimination” feature ensures quicksetup-and-go operation.

• Conforms to most special jobrequirements due to its modularnature.

83"

73"

48"

64"

Burner .......................................Single stage..............................................Diesel fuel/#1 or 2 heating oilInput capacity ........................182 KWOutput capacity .....................149 KWFuel consumption..................16.8 LPH, 14.3 KG/H

Weight.......................................Dry - 680 KG, Wet - 1,225 KGElectrical ...................................Single phase, 230 V, 50 Hz, 20 AmpsLoading - standard....................Forklift pockets, 4-point sling liftHeat exchanger ........................Water jacket / fire tube type

..............................................Fluid volume - 94.6 L

..............................................Fluid temp. range - 49°C to 93°CFuel tank ...................................Welded steel

..............................................Fuel capacity - 492 L

..............................................29.3 hr operating range at full outputClimate control system .............Maintains optimum burner reliability and

effiiciency at a full range of ambienttemperature conditions. Assures systemstart-up and operation in all conditions.

“Before system start-up”....Pre-heater.........................4000 Watt electric circulation heater,

240V, Preheats heat exchanger glycolbefore system start-up.

“During system operation”....Fuel heater........................Automatically maintains set fuel

temperature. Fluid (hot glycol)-to-fluid(fuel) heat transfer.

....Combustion air heater ......Automatically maintains set combustionair temperature. Fluid (hot glycol)-to-airheat transfer utilizing a heat transfer coil.

Control & monitoring .................Pump & temperature controls...............................................Full gauge panel showing circulation fluid

temperatures & pressures, fuel pressures...............................................8-light system operation feature for easy

system troubleshooting.Internal fluid circulation system

Basic features .......................Atmospherically vented, low pressure...............................................Single supply & return. ..............................................Adjustable fluid temperature control...............................................Auto pressure by-pass for pump

protection and variable flow demands...............................................Auto temperature bypass for heat

exchanger protection. Circulation pump ...................2900 RPM, 1-1/2 HP., 1.1KW..............................................Flow - 11.34 M³/HR @ 21 M W.C.Primary circulation.................Fluid circulation lines - 40 MM..............................................Ball valves - 40 MM ..............................................Kamlock quick couplers - 40 MM Heat transfer fluid (HTF) .......Non-toxic propylene glycol / water

mixture. ..............................................Freeze protected.Lock-out.................................locks out primary “supply” & “return” fluid

circulation valves and control panel

OptionalTransport trailerGenerator ..............................Diesel

Specifications

162.5 cm

122 cm

211 cm

186 cm

Please note: The black metal frame shown above does not feature on the units for sale.

olivertownend
Highlight
Page 2: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil

CHM2100-240EU 051116

Product Specs

Central Heating ModuleModel 2100-240EU

Burner .......................................Two stage, Diesel fuel/#1 or 2 heating oilInput capacity ........................260 KW/HOutput capacity .....................221 KW/HFuel consumption..................24.2 LPH, 20.7 KG/H

Weight.......................................Dry - 1,270 KG, Wet - 1,860 KGElectrical ...................................Single phase, 230 V, 50 Hz, 20 ALoading ....................................Forklift pockets, 4-point sling liftHeat exchanger ........................Water jacket / fire tube type

..............................................Fluid volume - 170 L

..............................................Fluid temp. range - 49°C to 93°CFuel tank ...................................Welded steel

..............................................Fuel capacity - 708 L

..............................................29 hrs operating range at full outputClimate control system .............Maintains optimum burner reliability and

efficiency at a full range of ambienttemperature conditions. Assures systemstart-up and operation in all conditions.

Before system start-up....Pre-heater.........................4000 Watt electric circulation heater,

230V, preheats heat exchanger glycolbefore system start-up.

During system operation....Fuel heater........................Automatically maintains set fuel

temperature. Fluid (hot glycol)-to-fluid(fuel) heat transfer.

....Combustion air heater ......Automatically maintains set combustionair temperature. Fluid (hot glycol)-to-airheat transfer utilizing a heat transfer coil.

Control & monitoring.................Pump & temperature controls. Full gauge panel showing circulation fluidtemperatures & pressures, fuel pressuresand 8-light system operation feature foreasy system troubleshooting.

Internal fluid circulation systemBasic features .......................Atmospherically vented & low pressure,

single supply & return, adjustable fluidtemperature control, auto pressure by-pass for pump protection and variableflow demands, auto temperature bypassfor heat exchanger protection.

Circulation pump ...................2900 RPM, 2 HP, 1.5KW,..............................................Flow - 16 M³/HR @ 21 M W.C.Primary circulation.................Fluid circulation lines - 50 MM..............................................Ball valves - 50 MM ..............................................Kamlock quick couplers - 50 MMHeat transfer fluid (HTF) .......Non-toxic propylene glycol / water

mixture, freeze protected.Lock-out package..................Locks out primary “supply” & “return” fluid

circulation valves and control panelOptional

Transport trailerGenerator ..............................Diesel

Specifications

Features• Diesel / light oil fired system• Temperature control and fuel usage is automatic.• includes unique “Climate Control” system which

ensures efficient and reliable burner operation in allconditions

• Compact and portable design for easypositioning on the work site.

• All system operation is controlled andmonitored from the central heatingmodule control panel

• 8-light system operation feature foreasy system troubleshooting.

• Fluid circulation system is lowpressure and atmospherically vented.There is no chance of an explosion orline burst due to pressure build-up.No special boiler certification isrequired to operate the system.

• Quick-connect hose couplers , “no-drain” fluid lines and a “rapid airelimination” feature ensures quicksetup-and-go operation.

• Add an optional diesel-poweredgenset for complete self-containedoperation on a non-powered site.

• Conforms to most special jobrequirements due to its modularnature.

163cm

145cm

249cm

201cm

Page 3: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil

PHE-25EU_PHE-60EU_051117

Features• Ideal for heating, drying and

climate control applications.• Their compact and mobile design

allows them to be positionedwhere required on the job site.

• The efficient fan/coil designprovides a high rate of heattransfer with built-in, high volumefans provide the heat delivery.

• High volume air flow ensures;• when heating... even heat

distribution throughout thestructure

• when drying... required air flowto effectively exhaustmoisture-laden air fromthe structure.• Clean, low humidity heatdelivery minimizes energycosts. With the DRYAIRsystem, you justrecirculate and re-heatwarm internal air, rather thanheating cold external air.• Provides the low humidityenvironment control essential forinhibiting mold growth.• Provides the optimum projectapplication environment for interiorfinish work.• Allows for daily application of jointcompound or finish texture todrywall.• Minimizes expansion andcontraction of wallboard.

• Reduces amount of downtime betweenfinished drywall and paint application.

• Eliminates shading of paint caused byresidue from open flame heaters.

• Allows better adhesion of caulkingmaterials.

• Provides a drier surface for application ofwater-based carpet and tile adhesives,epoxy and urethane coatings and epoxyjoint fillers.

• Reduces the chance of shrinkage atmitered joints in finish trim materials.

Portable Heat ExchangersPHE-25EU and PHE-60EU

Product Specs

SpecificationsPHE-25EU PHE-60EU

Blower .....................................G Series double inlet ......................................................G Series double inletMotor .......................................1/4 HP, 0.186KW ...........................................................1 HP, .75KW

Power...................................110/230V, single phase, 50 Hz, 3.7A..............................110/230V, single phase, 50 Hz, 12.7/6.4AControls ...................................thermostatic temperature control ....................................thermostatic temperature controlFluid circulation features

CoilPhysical properties ..........2-row copper tube, alluminum fin ...................................3-row copper tube, alluminum finKW output (based on 93°C supply fluid and 0°C ambient air).........................................23.5 KW (1,529 M3/hr air flow, 27 LPM fluid flow) ..........59 KW (3,908 M3/hr air flow, 68 LPM fluid flow)

Circulation............................single supply & return .....................................................single supply & returnFluid connection...................19 MM hydraulic style quick-couplers ...........................25 MM hydraulic style quick-couplers Circulation lines

Fluid lines ........................300 P.S.I. (2,068 kPa) heavy-duty hose .........................300 P.S.I. (2,068 kPa) heavy-duty hose.........................................19 MM I.D. x 15.2 M .......................................................25 MM I.D. x 15.2 MCouplers ..........................19 MM hydraulic style quick-couplers ...........................25 MM hydraulic style quick-couplers

Weight .....................................41 KG..............................................................................95 KG

OptionsHumidistat ............................Humidity controllerSky hook ..............................n/a ...................................................................................bolt-on

Please note: The PHE-25EU model shown above does not feature the black handle, feet or wheels, and is therefore smaller in size. The PHE-60EU is exactly as shown

olivertownend
Highlight
Page 4: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil

Product Specs

Plate Heat Exchanger PHE-FF-300EU

- for higt.-i'ise heating applications

- for heating separate fluid supply

Please note that this product may not be exactly as shown

Features: • The plate heat exchanger, combined with a central heating module,

is the perfect solution for delivering heat on a muti-storied projectwhile still keeping the heat source at ground level.

• Can circulate heat transfer fluid up to 21 M above the central heating

module's elevation utilizing our standard primary fluid lines.

• Provides a fluid distribution system totally separate from the central

Specifications

Heat transfer .. up to 293KW Weight - wet .. 227 KG Electrical . ....... 230V, single phase, 50Hz, 30A Pump ........... RPM - 3500

........... 3 HP, 2.24 KW ........... Flow - 18.12 M'/HR@ 24.5 M WC.

Controls & Monitoring ........... Pressure gauge for heat exchange circulation loop. ........... Supply and return temperature gauges for boiler

circulation loop . ... .. .... .. Supply and return temperature gauge for heat

exchanger circulation loop. ........... Pump control switch (on-off).

aBRYAIR Heat Thaw -'Cure

DRYAIR INC. DRYAIR INC.

91.4 cm

[]

heating module. The central heating module provides a fluid "hot" loop. The plate heat exchanger transfers heat from the central heating module "hot'' loop to the separate "plate heat exchanger" fluid distribution system.

HTF (heat transfer fluid) Circulation Central heating module circulation loop

Single supply and return ........... 50 MM (2") Kamlock quick couplers & ball valves

Plate heat exchanger circulation loop Single supply and return ........... 50 MM (2" ) Kam lock quick couplers & ball valves Primary circulation line .......... .40MM (1-1/2") primary circulation lines can be

used for applications delivering HTF fluid up to 122M .

. ...... .. .. 50MM(2") primary circulation lines must be used for applications delivering HTF fluid over 122 M .

PHE-FF-300EU 051123

DRYAIR UK Ltd. 606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: (306) 27&-4848, 1-888-750-1700, Fax: (306) 27&-4664 E-mail: [email protected] Web: www.dryair.ca

1095 N. Main Street, Bowling Green, Ohio, USA, 43402 Tel: (419) 354-8546, 1-866-354-8546, Fax: (419) 354-9706 E-mail: [email protected] Web: www.dryair.us

96 Huddersfield Road, Brighouse, Yorkshire, HOS 3RD, UK Tel: ++ 44 (0) 7921 908851, Fax:++ 44 1484 717614 E-mail: [email protected] Web: www.dryairuk.com

Page 5: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil
Page 6: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil

Product Specs

Hose reel HR3000 HR6000 041217

Hose ReelModels HR6000 &HR3000

• The reel’s primary purpose is todispense or collect fluid circulationhose on job sites.

• Available with 6000 or 3000 foot3/4” I.D. hose packages.

• “Unique” auto-feed system makeslaying out hose on a job site aone-man operation.

• Can also be used to store ordeploy other distribution systemhoses used in Dryair portableheating applications.

• Independent modular design offersthe following advantages overbuilt-in reels; You have the choiceof storing the hose reel at a securelocation on or off the job site whennot in use. Allows deployment ofhose at more than one job site.

• Transport trailers are available.

Controls...............................Variable rotational speed - 0 to 20RPM, forward/reverse.

.....................................Activation is automatic default (footswitch to load hose, auto-feedswitch to unload hose).

Hose loops .......................... 3/4” (1”O.D.) x 750’ hose loops with3/4” hydraulic-style quick couplers.

HR6000 ...........................Eight 750’ hose loops, for 9,000 sq.ft. coverage at 18” spacings

HR3000 ...........................Four 750’ hose loops, 4,500 sq. ft.coverage at 18” spacings.

Power requirements............ 115 VAC, 15 ampMotor................................... Leeson C6T17FB2D continuous duty

electric motor, 1 HP, 3-phase,

Adjustable frequency drive .Variable speed/soft-start AC motorcontrol, phase converter - 1 to 3phase, adjustable RMS current limit& motor overload protection,automatic reel rotation braking.

Torque limiter clutch............GLI Model 350, provides drive andmotor protection with a smoothclutching interface between thespool's high inertial forces and reel’sdrive components, allows 20 RPMto 0 RPM rotational speed reductionwithin a 1/4 revolution of the reel.

Load .................................... forklift accessible from all four sides Tarp cover ...........................weather and UV protection for the

fluid circulation hoseWeight .................................HR6000 - 4,355 lbs.

.....................................HR3000 - 2,870 lbs.

OptionalTransport trailers

Specifications

Features:

56"

68"

69"

NOTE: The 2nd picture shows the potential configuration of the powered hose reel and accompanying boiler on a mobile trailer. This can be configured as per the requirements of the client upon request, or both units can be trailer-mounted as standalone options.

Page 7: Product Specs Central Heating Module - ASSET · CHM2100-240EU 051116 Product Specs Central Heating Module Model 2100-240EU Burner.....Two stage, Diesel fuel/#1 or 2 heating oil