TECHNOLOGY
Sterilisation by ozone andUV-C radiation with particlefiltration in one unit.
In sterilization mode, the ozone (O3) produced by the sterilizer, as a very strong oxidant, has fungicidal, bactericidal and virucidal properties. Ozone also has the ability to neutralize all kinds of odors. Thanks to the high performance of the ozone generators used in the unit, the speed and efficiency of this method of decontamina-tion with STERYLIS sterilizers is extremely high. The total sterilization of the rooms is usually completed in about 4 hours and the whole pro-cess is controlled by a controller measuring the ozone concentration generated in the room in real time. Intelligent control of the ozone pro-cess ensures not only the highest sterilization efficiency but also the safety of the entire pro-cess. The safe concentration of ozone is possi-ble thanks to the function of its destruction after the sterilization process. Thanks to the gaseous form of the ozone generated, not only the air in the room is completely sterilized – so are all the objects in the room that ozone can reach during the decontamination process.
OZONEGENERATOR
STERYLIS sterilizers have 2-stage air filtration (pre-filter and exhaust filter). High-quality filter media with electrostatic properties are capa-ble of trapping even microscopic dirt particles. The use of an antibacterial system based on an odorless, non-toxic and invisible to the human eye coating applied to the filter medium allows to remove harmful allergens and bacteria from the air. This technology makes the STERYLIS sterilizers, in addition to their disinfection and sterilization functions, extremely effective also in cleaning air from particulate matter.
DOUBLE FILTRATION
ROOM STERILIZERS VS
are innovative disinfecting and sterilizing units with air filtration function, which use high-per-formance bacteriological and virucidal UV-C lamps and a very efficient ozone generator. This makes them extremely modern and versatile. They are available in several versions differing in the power of the UV-C source used, the efficiency of the ozone generator and the airflow efficiency. The series include the models: VS-450, VS-600, VS-900, VS-1200 ,VS-1500 and VS-1800.
UV-C RADIATION
A battery of high-performance UV-C lamps, lo-cated between the filters, emits a high intensi-ty of UV-C radiation in the sterilization channel with an appropriately selected λ wavelength of 253.7 nm. This causes the process of irreversible destruction of bacteria, viruses, molds, fungi and other microorganisms in the air flowing through the unit. Thanks to the special closed disinfection channel construction, the emitted high-energy UV-C radiation does not spread outside the inte-rior of the unit, which allows for safe operation of the sterilizer in this mode in rooms where people are present.
LIGHT AND SOUND SIGNALIZATION indicates that the unit is in the room sterilization cycle with ozone.
ERGONOMIC GRIP
THE START BUTTON protects against accidental activation of ozone sterilization.
THE SIGNAL LAMP signals a user-safe ozone concentration in the air after the ozone cycle.
LEDS SIGNALING individual modes of unit operation
LEDS ALERTING about the need to perform operations or failures of individual sterilization systems
ROTARY SWITCH that enables to select one of four modes of operation
MAIN SWITCH
CARTRIDGE FILTERS easy to replace
THE CONTROLLER WITH OZONE SENSOR manages the operation of the unit and analyzes the ozone concentration in the room
LEGS OR CASTORS depending on the model
UNIT FOR EVERYONE
INTUITIVE AND CONVENIENT
1
3
5
7
6
8
9
10
11
2
4
1 2
4
9
9
8
11
7
5
6
10
3
OKOKSAFETY
SIMPLEOPERATION
Signal and warning lights and acoustic signals generated by the device inform the user about the sterilization mode activated and the safe or excessive level of ozone concentration in the room. Whenever the device detects that the concentration limit has been exceedes, it adjusts its own performance while ensuring maximum safety.
The controller the unit is equipped with is in-tuitive, functional and very simple to use. The operating modes are changed by means of an intuitive knob. Signal lights visible from a dis-tance allow you to conveniently assess from a distance which operating mode the device is currently in; safety messages are signaled in the same way. The panel is also equipped with lights displaying alerts concerning the necessity of unit maintenance, including signaling the ne-cessity of filter replacement. Along with acous-tic signaling, the flashing signal lamp visible from a distance provide safety in sterilization mode. These are just some of its functions.
SILENT OPERATION
By changing the operating mode to "UV-C dis-infection SILENT MODE", the unit switches to low fan speed operation at low fan speed and switches to quiet operation. From now on, the user's peaceful sleep with the simultaneous operation of the sterilizer is not at risk.
CONVENIENCE
Intelligent air sterilizers provide maximum com-fort. They shall inform users of the need to re-place filters, of the need to replace UV-C lamps if their service life is exceeded or if they burn out, and of damage to other components, e.g. one of the ozone generators, if any. This is by far the highest level of self-diagnosis in such units.
PROFESSIONAL ROOM STERILIZERS
Bacteria, viruses, and other pathogens are transferred to the sterilizer.1
1
The cleaned air is returned to the room through a second outlet filter.5
5
6
7
Pre-filtration of particulates.2
2
The molecular structure of the DNA of pathogens is broken down, which completely neutralizes them.4
4Pathogens in the air are exposed to UV-C radiation.3
The molecular oxygen contained in the air is supplied to an ozone generator located inside the sterilizer.
Once the sterilization process is complete, the unit enters into UV ozone destruction mode, speeding up the time needed to achieve a concentration of O3 safe for the user.
Once the safe ozone concentration is reached, the sterilization cycle is completed and the sterilizer enters the standby mode.
The room is sterile, free of pathogens.
Crown discharges separate oxygen molecules.
Once the concentration of ozone as a gas has been achieved, it reaches all corners of the room, neutralizing pathogens.
Single oxygen atoms bond with oxygen molecules to form ozone molecules ( O3 ).
3
HOW THE UV-C DISINFECTION TECHNOLOGY WORKS WITHPATHOGENS
WHAT A FULL CYCLE OF OZONE STERILIZATION LOOKS LIKE
OKOK
UV-C RADIATION DOSE REQUIRED TO NEUTRALISE THE PATHOGEN
Agrobacterium Lumefaciens 85Acinetobacter 14Bacillus Anthracis 87Bacillus Anthracis Spores 462BaciHus Megatherium Sp. (Veg) 25Bacillus Megatherium Sp. (Spores) 52Bacillus Paratyphosus 61Bacillus Subtilis 110Bacillus Subtilis Spores 220Bordetella pertussis 63Clostridium Tetani 231Clostridium Botulinum 112Corynebacterium Diphtheriae 65Dysentery BaciIli 42Eberthella Typhosa 41Enterobacter cloacae 64Enterococcus 28Escerichia Coll 86Haemophilus influenzae 19Haemophilus parainfluenzae 77Klebsiella pneumoniae 52Legionella pneumophila 11Legionella Dumoffill 55Legionella Gormanil 49Legionella Micdadei 31Legionella Longbeachae 29Leglonella Pneumophfla 27Leptospiracanicola - Infectious Jaundice 60Leptospira Interrogans 80Micrococcus Candidus 123Micrococcus Sphaeroides 154Mycobacterlum Tuberculosis 100Neisseria Catarrhalis 85Phytomonas Tumefaciens 105Proteus Vulgaris 39Pseudomonas Aeruginosa 66Pseudomonas Fluorescens 76Rhodospirillum Rubrum 61Salmonella Enteritidis 100Salmonella Paratyphi 152Salmonella Species 70Salmonella Typhimurium 105Salmonella Typhosa 264Salmonella 61.6Sarcina Lutea 42Serratia Marcescens 34Shigella Dysenteriae-Dysentery 34Shigella Flexneri-Dysentery 70Shigella Paradysenteriae 85Shigella Sonnei 66Spirillum Rubrum 61.6Staphlylococcus Albus 57.2Staphlylococcus Aureus 66Staphlylococcus Epidermidis 58Streptococcus Faecaila 100Streptococcus Hemolyticus 55Streptococcus Lactis 88Streptococcus Pyrogenes 42Streptococcus Salivarius 42Streptococcus Viridans 38Typhoid Fever 41Vibrio Comma (Cholera) 65Vibrio Cholerae 65
Adenovirus 45BacterIophage (E.Coli) 66Coronavirus (SARS) 18SARS Coronavirus CoV-P9 40Murine Coronavirus (MHV) 103SARS Coronavirus (Hanoi) 134SARS Coronavirus (Urbani) 241Coxsackievirus 63Infectious Hepatitis 80lnfluenza 34Measles virus 22Mumps virus 30Norwalk virus 198Parainfluenza virus 21Parvovirus B19 25Poliovirus 210Reovirus 158Rhinovirus 162Rotavirus 240RSV 25Rubella virus 622VZV (Varicella surrogate k) 18Variola 240
Aspergillus Amstelodami 770Aspergillus Flavus 990Aspergillus Glaucus 880Mucor Mucedo 770Mucor Racemosus (A & B) 352Oospora Lactis 110Penicillium Chrysogenum 560Penicillium Digitatum 880Penicillium Expansum 220Penicillium Roqueforti 264
Chlorella Volgaris (atgae) 220E. Hystolytica 840Nematode Eggs 400
Aspergillus spores 258Baker’s Yeast 88Blastomyces dermatitidis spores 140Brewer’s Yeast 66Common Yeast Cake 132Cryptococcus neoformans spores 138Fusarium spores 269Mucor spores 228Rhizopus spores 267Saccharomyces Cereisiae 132Saccharomyces Ellipsoideus 132Saccharomyces Sp. 176
BACTERIA [ J/m2 ] [ J/m2 ]
[ J/m2 ]
[ J/m2 ]
[ J/m2 ]
MOLDS
PROTOZOANS
VIRUSES
FUNGI
The UV-C radiation dose required for a 99.9% pathogen reduction is shown in the table. The exemplary data given are collected from scientific publications and research on ultraviolet light sterilization technology from around the world.
The degree of deactivation with ultraviolet radiation is directly related to the UV-C radiation dose applied. The UV-C dose is the product of the irradiance [ I ] and the exposure time [ t ]. Therefore: DOSE = I x tThe UV-C radiation dose is expressed in joules per square meter [ J/m2 ].
The dose of UV-C radiation generated during one passage of air through the full volume of the disinfection chamber
STERYLIS unit model VS-450 VS-600 VS-900 VS-1200 VS-1500 VS-1800
UV-C disinfection operating mode (silent)
Dose [ J/m2 ] 71 354 390 419 1162 1102
Efficiency [ m3/h ] 165 155 200 240 280 380
UV-C disinfection operating mode
Dose [ J/m2 ] 53 250 211 135 406 400
Efficiency [ m3/h ] 220 220 370 740 800 1050
Disi
nfec
ted
cubi
c cap
acity
[m3 ]
UV-C disinfection (silent mode) UV-C disinfection (standard mode)
Time [h]
UV-C RADIATION DOSE GENERATED BY THE UNITDURING DISINFECTION
Disi
nfec
ted
cubi
c cap
acity
[m3 ]
Time [h]
IN PRACTICALLY EVERY ROOM!
PLACES OF USE
STERYLIS VS devices are adapted to every type of room and to different cubic capacities. Their power and performance allows them to be adjusted to operate both during the day and at night (night mode - silent). They are characterized by many advantages, such as safety, convenient usage / service / and simple operation.
Key:T1 - time to reach the sterilizing ozone concentration (default 5 ppm)T2 - supervised by the controller, required time of the sterilization process depending on the achieved ozone concentrationT3 - supervised by the controller, supported by an ozone destructor, time of the process of returning to a safe ozone
concentration
HOW THE OZONE PROCESS INSTERILIZED ROOMS LOOKS LIKE
MODEL
RECOMMENDED STERILIZED CUBIC
CAPACITY (in ozonization
mode) [m3]
MAXIMUM STERILIZED CUBIC
CAPACITY (in ozonization
mode) [m3]
STERYLIS VS-450 450 3400
STERYLIS VS-600 600 5000
STERYLIS VS-900 900 6800
STERYLIS VS-1200 1,200 10,000
STERYLIS VS-1500 1,500 11,500
STERYLIS VS-1800 1,800 13,500
Scope of application in sterilization mode (O3)
Chart of ozone sterilization time depending on the volume of the room to be sterilized
Chart of the sterilization process in the room
Sterilization time T1+T2-T3
Ozone concentration ppm
Time [h]
Ster
ilizat
ion
time
[h]
Room cubic capacity [m3]
FLATS
HOSPITALS
OFFICES
SHOPS
CITY OFFICES
BARBER SHOPS
CONFECTIONERIES AND BAKERIES
CAR WORKSHOPS
CAR SHOWROOMS
PHARMACIES
FACTORIES
AND MANY MORE
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R SVS-450
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
450 m3
Efficiency – filtering mode 220 m3/h
Noise level – filtering mode 45 dB(A)
Efficiency – disinfection mode UV-C (silent) 165 m3/h
Noise level – disinfection mode UV-C (silent) 40 dB(A)
Efficiency – disinfection mode UV-C 220 m3/h
Noise level – disinfection mode UV-C 45 dB(A)
Efficiency – sterilization mode O3+UV-C 265 m3/h
Noise level – sterilization mode O3+UV-C 52 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 54 W
Durability of UV lamps 9000 h
Power of the UV light source 14.4 W
Initial maximum UV-C radiation dose 71 J/m2
MO
DEL
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
450 m3
VS-450
360 275
700±
10
MO
DEL
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
57 J/m2
Ozone generator YES
Ozone generator capacity 30,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 1.5 A
Rated power 350 W
Power cable length 3.5 m
Dimensions (H x W x D) 700 x 360 x 260
Net weight 18 kg
Type of housing metal, powder-coated
Transport wheels/handles handle
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
* - option depending on version
Filtration
UV-C disinfection - silent mode
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R SVS-600
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
600 m3
Efficiency – filtering mode 200 m3/h
Noise level – filtering mode 43 dB(A)
Efficiency – disinfection mode UV-C (silent) 155 m3/h
Noise level – disinfection mode UV-C (silent) 38 dB(A)
Efficiency – disinfection mode UV-C 220 m3/h
Noise level – disinfection mode UV-C 43 dB(A)
Efficiency – sterilization mode O3+UV-C 220 m3/h
Noise level – sterilization mode O3+UV-C 50 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 100 W
Durability of UV lamps 9000 h
Power of the UV light source 28 W
Initial maximum UV-C radiation dose 354 J/m2
MO
DEL
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
600 m3
VS-600MO
DEL
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
283 J/m2
Ozone generator YES
Ozone generator capacity 45,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 2.2 A
Rated power 500 W
Power cable length 3.5 m
Dimensions (H x W x D) 950 x 360 x 260
Net weight 20 kg
Type of housing metal, powder-coated
Transport wheels/handles handle
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
360 275
950±
10
* - option depending on version
Filtration
UV-C disinfection - silent mode
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R SVS-900
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
900 m3
Efficiency – filtering mode 260 m3/h
Noise level – filtering mode 42 dB(A)
Efficiency – disinfection mode UV-C (silent) 200 m3/h
Noise level – disinfection mode UV-C (silent) 36 dB(A)
Efficiency – disinfection mode UV-C 370 m3/h
Noise level – disinfection mode UV-C 42 dB(A)
Efficiency – sterilization mode O3+UV-C 370 m3/h
Noise level – sterilization mode O3+UV-C 48 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 150 W
Durability of UV lamps 9000 h
Power of the UV light source 42 W
Initial maximum UV-C radiation dose 390 J/m2
MO
DEL
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Filtration
UV-C disin-fection - silent mode
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
900 m3
VS-900MO
DEL
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
312 J/m2
Ozone generator YES
Ozone generator capacity 60,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 2.9 A
Rated power 660 W
Power cable length 3.5 m
Dimensions (H x W x D) 1050 x 700 x 490
Net weight 35 kg
Type of housing metal, powder-coated
Transport wheels/handles transport wheels
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
700
1050
525
* - option depending on version
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R SVS-1200
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
1200 m3
Efficiency – filtering mode 520 m3/h
Noise level – filtering mode 43 dB(A)
Efficiency – disinfection mode UV-C (silent) 240 m3/h
Noise level – disinfection mode UV-C (silent) 37 dB(A)
Efficiency – disinfection mode UV-C 740 m3/h
Noise level – disinfection mode UV-C 43 dB(A)
Efficiency – sterilization mode O3+UV-C 740 m3/h
Noise level – sterilization mode O3+UV-C 49 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 200 W
Durability of UV lamps 9000 h
Power of the UV light source 56 W
MO
DEL
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
1200 m3
VS-1200MO
DEL
Initial maximum UV-C radiation dose 419 J/m2
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
335 J/m2
Ozone generator YES
Ozone generator capacity 90,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 4,3 A
Rated power 990 W
Power cable length 3.5 m
Dimensions (H x W x D) 1050 x 700 x 490
Net weight 38 kg
Type of housing metal, powder-coated
Transport wheels/handles transport wheels
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
700
1050
525
* - option depending on version
Filtration
UV-C disinfection - silent mode
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R S
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
1500 m3
Efficiency – filtering mode 600 m3/h
Noise level – filtering mode 44 dB(A)
Efficiency – disinfection mode UV-C (silent) 280 m3/h
Noise level – disinfection mode UV-C (silent) 38 dB(A)
Efficiency – disinfection mode UV-C 800 m3/h
Noise level – disinfection mode UV-C 44 dB(A)
Efficiency – sterilization mode O3+UV-C 800 m3/h
Noise level – sterilization mode O3+UV-C 50 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 330 W
Durability of UV lamps 9000 h
Power of the UV light source 105 W
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Filtration
UV-C disinfection - silent mode
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
1500 m3
VS-1500MO
DEL
Initial maximum UV-C radiation dose 1,162 J/m2
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
929 J/m2
Ozone generator YES
Ozone generator capacity 105,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 5,3A
Rated power 1,230 W
Power cable length 3.5 m
Dimensions (H x W x D) 1450 x700 x 710
Net weight 55 kg
Type of housing metal, powder-coated
Transport wheels/handles transport wheels
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
VS-1500MO
DEL
700
1450
735
* - option depending on version
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
IGLOO Sp. z o.o. Stary Wiśnicz 289, 32-720 Nowy Wiśnicz Poland, NIP: 8681976604, KRS: 0000822253 tel.: +48 14/ 662 19 10, e-mail: [email protected] www.sterylis.igloo.pl
P R O F E S S I O N A L R O O M S T E R I L I Z E R S P R O F E S S I O N A L R O O M S T E R I L I Z E R S
Type flow type
Recommended maximum cubic capacity of the sterilized room ( to achieve 5 ppm O3 )
1800 m3
Efficiency – filtering mode 600 m3/h
Noise level – filtering mode 44 dB(A)
Efficiency – disinfection mode UV-C (silent) 380 m3/h
Noise level – disinfection mode UV-C (silent) 38 dB(A)
Efficiency – disinfection mode UV-C 1,050 m3/h
Noise level – disinfection mode UV-C 44 dB(A)
Efficiency – sterilization mode O3+UV-C 1,050 m3/h
Noise level – sterilization mode O3+UV-C 50 dB(A)
Air filtering 2-stage
Fan type Radial
Fan engine enclosed
UV lamp YES
Type lamps UV UV-C sterilization λ= 253.7 nm
Electrical power of UV lamps 440 W
Durability of UV lamps 9000 h
Power of the UV light source 140 W
TECHNICAL SPECIFICATIONS:
Recommended
CUBATURE of the sterilized room(to achieve 5 ppm O3)
WORK MODES:
Disinfection UV-C
Sterilization O3 + UV-C (Auto)
1800 m3
VS-1800MO
DEL
Initial maximum UV-C radiation dose 1,102 J/m2
Maximum radiation dose taking into account the drop in performance of the UV-C source after 9,000 hours of operation
882 J/m2
Ozone generator YES
Ozone generator capacity 120,000 mg/h
ozone concentration sensor YES
Ozone destructor YES
Controller YES
Automatic mode of operation YES (control of sterilization time according to actual ozone concentration readings)
Self-diagnosis YES
Working time counter YES (signalling the replacement of filters and UV rays)
Power supply 230 V (AC), 50 Hz
Rated current 6.3 A
Rated power 1,450 W
Power cable length 3.5 m
Dimensions (H x W x D) 1450 x700 x 710
Net weight 60 kg
Type of housing metal, powder-coated
Transport wheels/handles transport wheels
Additional functions signaling safe and excessive ozone levels, remote control*, removable power cord
VS-1800MO
DEL
700
1450
735
* - option depending on version
Filtration
UV-C disinfection - silent mode
P R O F E S S I O N A L R O O M S T E R I L I Z E R S
IGLOO Stary Wiśnicz 28932-720 Nowy WiśniczPoland
[email protected] sterylis.igloo.pl