profibus. plc profibus active stations, master devices driveactuatortransmitter passive stations,...
TRANSCRIPT
ProfibusProfibus
PLC
PROFIBUS
active stations, master devices
Drive Actuator Transmitter
passive stations, slave devices
Sensor Sensor Drive
logical token ring between the master stations
Sensor
M M T
PLCPLC
PROFIBUS - Token Ring
Device Data Base FilesGSD-file
Profimap PROFIBUS configuration tool
System configuration
PLC
Fielddevice
I/O Sensor Drive
MTrans-mitter
Fielddevice
PROFIBUS - DP
Open Configuration with PROFIMAP
Device Data Base FilesGSD-file
PROFIBUS configuration tool
System configuration
Fielddevice
I/O Sensor Drive
MTrans-mitter
Fielddevice
PROFIBUS - DP
PC Based Control
Open Configuration with PC Based Control
Bus TerminatorResistance
A1SJ71PB92D
Mode
RS-232-C
ProfibusI/F
Bus Termination
On Off
################
################
######
ProfiMap Cable
To Profibus DPNetwork
Melsec ProfiMapConfiguration Software
Mode Selection
– 0 = On-Line *
– 1 = PRM Set
– 2 = Test
– E = Online #
* 32 I/O byte mode
#244 I/O byte mode
(version BE or later)
A1SJ71PB92D Module Details Hardware Configuration
AJ71PB92D
Mode
RS-422
ProfibusI/F
Bus Termination
On Off
################
################
######
To Profibus DPNetwork
Melsec Profimap Ver 2.0 up
Mode Selection
– 0 = On-Line *
– 1 = PRM Set
– 2 = Test
– E = Online #
* 32 I/O byte mode
#244 I/O byte mode
Bus TerminatorResistance
ProfiMap Cable
AJ71PB92D Module DetailsHardware Configuration
DP Master Module ConfigurationHas the capability to support 60 Slave UnitsEach Slave can address 32 Bytes Input Data / 32 Bytes Output DataExtended capacity up to 244 I/O bytes * per slaveDiagnostic Area for Slave fault InformationDiagnostic Buffer for master module faultsOn-Board Termination resistorSupports Global Functions
* On AnS module versions BE or later, all AJ71PB92D versions
ProfiMap Configuration Software
Many devices can be added, as shown
The “Create POU” button is a direct link to MM+
A POU is created as an ascii file
Page 118
The ascii file can be imported from theProject menu, as shown.
Page 119
A POU has been created, in Melsec IL, containing, TO/FROM statements, for allstations on the Profibus network. Buffer memory is allocated in ascending stationnumber order.
The information filledin at this stage, are thesource/destination forthe TO/FROM instructions in the POU.
Mitsubishi and Profibus DP Mitsubishi have the following devices that support the Profibus DP Protocol:
– FX0N/FX2N PLC with FX0N-32NT-DP add on block– FX2N-32DP-IF I/O adaptor interface – E range of Operator Interfaces– FR-PBM Inverter Drive Interface (A024/A044/A140/A240)– A500 Inverter Drives (with FR-A5NP interface)– Remote I/O AJ95TB3-16D 16 way input– AJ95TB2-16T 16 way trans output– AJ95TB32-16DT 8 way input / 8 way output– MT Series I/O digital and analogue I/O
3 8
Profibus I/F 9 PinA(1S)J71PB92DMaster Module
FR-PBM
3 8 3 8
..
..
3 8
..
MAC E range + IFC PBDP
Profibus DP
RS422/485
Mitsubishi Profibus DP Connections
DigitalRemote
I/O
3 8
..
FX0N/FX2N PLC+
FX0N-32NT-DP
Up to 32 Nodes per Master Module without repeaters
Pr 7
1 2 34 5 67 8 9
FR - PU02E
3 8
..
Pr 7
1 2 34 5 67 8 9
FR - PU02E
A024/A044A140/A240 Drives
A500 Drives+
FR-A5NP
Earthing not shown see earlier slides
Remote I/OFX2N32DP-IF
+standard I/O,
analogue,high speed I/P
Blocks
3 8
..
3 8
..
Digital/AnalogueRemote
I/O
Remote I/OAJ95TB3-16D 16 way inputAJ95TB2-16T 16 way transistor outputAJ95TB32-16DT 8 way input / 8 way output
Fixed Digital I/O Blocks
Mitsubishi I/O Options
MT Series Flexible I/O Blocks
Base Module - 16 modules (up to 8 analogues) can be connected
Digital Module - 8/16 inputs and 4/8/16 outputs are available. Outputs in relay or transistor types
Analogue Module - 4 inputs and 4 outputs are available. 12 bit resolution
Mitsubishi I/O Options
FX2N 32DP-IF - Interface Solution
FX2N 32DP-IF allows standard FX0N/2N extension blocksto be coupled together as a Profibus DP I/O station
FX2N 16/32/48 Digital I/O blocksFX0N 8/16 Digital I/O blocksFX2N 4DA/AD 4 channel analogue output/input blocksFX2N 4AD-PT 4 channel PT100 sensor inputFX2N 4AD-TC 4 channel thermocouple input
Standard FX blocks can be used with an adapter cable
Mitsubishi I/O Options
Questions?
ProfibusProfibus