profile application imp roof panels commercial -...

21
42" COVERAGE 1 1 2 " 1 1 2 " 1 8 " 4" REV. SHT. DATE APPLICATION PROFILE DETAIL NOTES: A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS. B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE. IMP ROOF PANELS COMMERCIAL - INDUSTRIAL SKYLINE ROOF PANEL PROFILE IMP-100 JAN 6/21 A 1 2 " VARIES 2" varies EXTERIOR FACING SKYLINE ROOF PANEL WIDTH: 42" PROFILE: MESA INSULATION THICKNESS: 2", 4", 5", 6" EXTERIOR FACING: 22ga, 24ga INTERIOR FACING: 22ga, 24ga, 26ga AVAILABLE FINISHES: SMOOTH/SMOOTH, LIGHT EMBOSSED INTERIOR FACING INSULATION DISCLAIMER THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS. A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL AUTHORITES HAVING JURISDICTION. STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS. ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS, SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.

Upload: others

Post on 09-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

42" COVERAGE

1

1

2

" 1

1

2

"

1 8

"

4"

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

SKYLINE ROOF PANEL PROFILE IMP-100 JAN 6/21 A

1

2

"

VARIES

2"

varies

EXTERIOR FACING

SKYLINE ROOF PANEL

WIDTH: 42"

PROFILE: MESA

INSULATION THICKNESS: 2", 4", 5", 6"

EXTERIOR FACING: 22ga, 24ga

INTERIOR FACING: 22ga, 24ga, 26ga

AVAILABLE FINISHES: SMOOTH/SMOOTH, LIGHT EMBOSSED

INTERIOR FACING

INSULATION

DISCLAIMER

THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING

TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.

A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS

INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL

AUTHORITES HAVING JURISDICTION.

STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.

ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,

SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.

Page 2: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL INSTALLATION - SEQUENCE 1 IMP-101 JAN 6/21 A

SECTION A - ROOF PANEL @ OUTER FACE SECTION B - ROOF PANEL @ OUTER FACE

R

O

O

F

P

A

N

E

L

B

A

OUTER FACE

STRUCTURAL EAVE

ROOF PANELEAVE

2"

1"

ROOF PANEL

RAKE ANGLE

OUTER FACE

NOTES:

- FIELD CUT PANEL TO REQUIRED WIDTH.

- USE "C" CLAMPS TO TEMPORARILY HOLD THE CUT EDGE OF THE PANEL

TO THE RAKE ANGLE AND FASTEN AS SPECIFIED.

JOINT CENTERED ONSTRUCTURAL SUPPORT

3"x4" CONTINUOUS ANGLE@ PANEL ENDLAP.JOINT GAUGE TO MATCH PURLINS(PURLINS BY FRAMING SUPPLIER)

ALIGN PANEL AS PER SECTIONS"A" & "B" @ EAVE & RAKE

INSTALL CONCEALED FASTENER CLIPS ON THEROOT PANEL W/ BUTYL SEALANT SUBSEQUENT TORAKE FASTENING. CRIMP CLIPS WITH MANUAL SEAMING TOOL.REFER TO DETAIL IMP-102 FOR MORE INFORMATION.

Page 3: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL INSTALLATION - SEQUENCE 2 IMP-101A JAN 6/21 A

3"x4" CONTINUOUS ANGLE@ PANEL ENDLAP.JOINT GAUGE TO MATCH PURLINS(PURLINS BY FRAMING SUPPLIER)

NOTES:

- STAND ON ROOF PANEL 2 TO FIRMLY SEAT ENDLAP. INSPECT THE GAP BETWEEN THE ROOF PANELS

TO ENSURE A TIGHT FIT.

- INSTALL TWO CLIPS AT PANEL ENDLAP FOLLOWING EDGE FASTENING. CRIMP BOTH CLIPS WITH MANUAL

SEAMING TOOL BEFORE INSTALLING NEXT COURSE OF PANELS.

- REFER TO DETAIL IMP-101B FOR MORE INFORMATION

ROOF PANEL 1

ROOF PANEL 2

JOINT CENTERED ONSTRUCTURAL SUPPORT

FASTEN OVERLAP JOINT @ EACHHIGH MESA INTO BACKUP PLATES

APPLY TAPE SEALANT ALONG CONNECTED EDGE

CUT UPPER COURSE OF PANEL 2 TOMATCH WIDTH OF STARTER PANEL 1

PLACE PANEL 2 INTO POSITION; ALIGN LEADING EDGEUSING SEAM CLAMP AND ATTACH CUT EDGE OF PANEL 2

TO PURLINS USING SPECIFIED FASTENER.

Page 4: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL INSTALLATION - SEQUENCE 3 IMP-101B JAN 6/21 A

PANEL ATTACHMENT (1) PANEL ATTACHMENT (2)

NON-SKINNING BUTYL [SL05]

3/32"x1/2" BUTYL TAPE [SL01] USE MANUAL SEAMER TO CRIMP SEAMSFOR 12"-18" @ RIDGE, EAVES, AND END LAPS.USE ELECTRIC SEAMER ON REMAININGROOF AREAS.

NOTE:

- USE RIB CLAMPS TO PULL PANEL SIDELAPS TOGETHER.

NEXT ROOF PANEL

INSTALLED ROOF PANEL

POSITION ROOF AS SHOWN, HOOKFEMALE LAP OVER MALE LEG OF

PANEL 1 AND ROTATE INTO POSITION.

Page 5: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL SIDELAP IMP-102 JAN 6/21 A

NOTE:

- USE CLAMPS TO ENSURE PROPER PANEL ALIGNMENT.

3/32"x1/2" BUTYL TAPE [SL01] OVER PANEL AND UNDERCLIP EXTEND MIN. 2" PAST EACH SIDE OF CLIP.

CLIP

CONTINUOUS 3/32"x1/2" BUTYL TAPE [SL01]

VARIES

CONCEALED FASTENER CLIP @ EACHSUPPORT LOCATION [CF02]W/ 3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP

NON-SKINNING BUTYL [SL05]

SD3-#14x2 1/2"-HW 3/8" (MIN. 3 PER CLIP)

STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)

3/32"x1/2" BUTYL TAPE [SL01]

HAND "CRIMP" THE STANDING SEAM @ RIDGE, ENDLAPS, AND EAVES.MECHANICALLY SEAM SUBSEQUENT TO RIDGE, RAKE, AND EAVE COMPONENT INSTALLATION.

VARIES

STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)

APPLY BUTYL SEALANT TO PANELEDGE. INSPECT SEALANT IF FACTORYINSTALLED.

SECURE TO PURLINS W/ SPECIFIEDFASTENERS.

INSTALL CFR CLIP W/ BUTYL SEALANT

HAND "CRIMP" THE STANDING RIB/CLIPASSEMBLY AT EACH CLIP LOCATION

INSTALL CONTINUOUS 3/32"x1/2" BUTYL TAPE [SL01]ON TOP OF MALE STANDING SEAM.

TILT NEXT PANEL TO BE INSTALLEDAT 45° ANGLE. ROTATE INTO POSITION.

STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)

3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP

Page 6: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL CLIP CONNECTION IMP-102A JAN 6/21 A

INSULATED METAL ROOF PANELCONCEALED FASTENER CLIP [CF02]@ EACH SUPPORT LOCATION

V

A

R

IES

2

1

/2

" M

IN

.

B

E

A

R

IN

G

S

U

R

FA

C

E

SD3-#14x2 1/2"-HW3/8" (3 PER CLIP)

STRUCTURAL PURLIN SUPPORT(BY FRAMING SUPPLIER)

3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP.EXTEND TAPE 1/4" ON EACH SIDE.

Page 7: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

ROOF PANEL ENDLAP IMP-103 JAN 6/21 A

3" LA

P PA

N

EL

C

U

T B

A

C

K

1"

SD3-#14x1" HW 3/8" ENDLAPENSURE FASTENERS ARE DRIVEN INTO THE

ROOF SPLICE PLATES INSIDE THE LOWER PANEL.

3/32"x2 1/2" BUTYL TAPE [SL01]

LOWER ROOF PANEL 2 1/2"

V

A

R

IES

V

A

R

IES

FIELD NOTCH TOP FLANGE

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT

UPPER ROOF PANEL

ENSURE TIGHT FIT (MAX 1/16" GAP)

SD3-#14x2 1/2"-HW3/8" (MIN. 3 PER CLIP,PER ENGINEERING DESIGN)

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT.

2) ROWS NON-SKINNING BUTYL [SL05]PROVIDE MARRIAGE BEAD FOR LOWERAND UPPER ROOF PANEL.

2

1

/2

" M

IN

.

B

E

A

R

IN

G

S

U

R

FA

C

E

2

1

/2

" M

IN

.

B

E

A

R

IN

G

S

U

R

FA

C

E

3/16"x2 1/2" BUTYL TAPE [SL04]CENTRED ON THE PURLIN/ANGLE

FASTENERS (BY FRAMING SUPPLIER)

STRUCTURAL PURLIN SUPPORT(BY FRAMING SUPPLIER)

STRUCTURAL SUPPORT ANGLE(BY FRAMING SUPPLIER)

CONCEALED FASTENER CLIP [CF02]@ EACH SUPPORT LOCATION

W/ 3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP.

EXTEND TAPE 1/4" ON EACH SIDE.

NOTE:

- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.

- END LAP STEEL LOCATION IS CRITICAL TO ROOF PANEL LENGTH.

MINIMUM ROOF SLOPES:

1/4" in 12" CONTINUOUS ROOF

1" in 12" ROOF WITH ENDLAP

1/2" in 12" ROOF WITH ENDLAP - CONSULT MANUFACTURER

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

Page 8: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

HIGH EAVE IMP-104 JAN 6/21 A

V

A

R

IES

VARIES

1 8

"

1

" O

FFS

E

T

FA

C

E

O

F W

A

LL P

A

N

E

L

T

O

R

O

O

F P

A

N

E

L

NOTE:

- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH.

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.

STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)

INSULATED METAL WALL PANEL

3/16"x7/8" BUTYL TAPE [SL02]

SDL-#14x7/8"-HW5/16"-GB9/16" @ 8" O/C

HIGH EAVE [TR02-03]

FIELD INSTALLED FILLER INSULATION(BY OTHERS)

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

SDL-#14x7/8"-HW5/16"-GB9/16"@ 6" O.C. OUTSIDE CLOSURE

1/4"x7/8" BUTYL TAPE [SL03]

CLOSURE ZEE RIDGE CAP TRIM [TR09-02 (42" LONG)](FILL ALL GAPS WITH URETHANE POLYSEAL [SL06])

ROOF PANEL

1/4"x7/8" BUTYL TAPE[SL03]

WALL PANEL CLIP [CF01]

MINIMUM (3) FASTENERS(TYPE PER ENGINEERING DESIGN)

NON-SKINNING BUTYL [SL05]2) 1/4" BEADS BOTH LOCATIONS

SD3-#14x2 1/2"-HW3/8" (3 PER CLIP)

CONCEALED FASTENER CLIP @ EACHSUPPORT LOCATION [CF02]

3

1

/2

"

M

A

X

.

FIELD INSTALLED FILLER INSULATION(BY FRAMING SUPPLIER)

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

Page 9: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

3" PA

N

EL

C

U

T B

A

C

K

1

4

"

VARIES

V

A

R

IES

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

LOW EAVE WITH GUTTER IMP-105 JAN 6/21 A

6

"

2"

1"

NOTE:

- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.

INSULATED METAL WALL PANEL

WALL PANELCLIP [CF01]

STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)

MINIMUM (3) FASTENERS.(TYPE PER ENGINEERING DESIGN)

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

SD3-#14X2 1/2"-HW3/8"

(3 PER CLIP)

MIN. 2 1/2" BEARING

SURFACE

ROOF PANEL

CONCEALED FASTENER CLIP @ EACH

SUPPORT LOCATION [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

SDL-#14X7/8"-HW5/16"-GB9/16"

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS

SEALANT LINES @ PANEL JOINT

(2) SDL-#14X7/8"-HW5/16"-GB9/16"

@ EACH SIDE OF STANDING SEAM

3/16"x7/8" BUTYL TAPE [SL02]

LOW EAVE TRIM [TR02-01]

SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.

FIELD INSTALLED

FILLER INSULATION

(BY OTHERS)

GUTTER TRIM [TR13-01]

WITH CAULKING @ LAPS,

END CAPS AND FASTENERS

GUTTER INTERNAL SUPPORT

BRACKET [AC01-02] @ EACH

PANEL SEAM C/W

ADDITIONAL GUTTER SUPPORT

MID SPAN OF PANEL SEAM

SDL-#14X7/8"-HW5/16"-GB9/16"

(2) SDL-#14X7/8"-HW5/16"-GB9/16"

GUTTER STRAP [AC01-01]

@ EACH PANEL SEAM

3/16"x7/8" BUTYL TAPE [SL02]

3/32"x1/2" BUTYL TAPE

[SL01]

SDL-#14X7/8"-HW5/16"-GB9/16"

(@ EACH HIGH MESA 4" O/C)

1" OFFSET

NON-SKINNING BUTYL [SL05]

NON-SKINNING BUTYL [SL05]

Page 10: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

LOW EAVE WITH TRIM IMP-105A JAN 6/21 A

2"

1"

3" PA

N

EL

C

U

T B

A

C

K

1" OFFSET

1" O

FFSET

V

A

R

IES

VARIES

NOTE:

- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.

STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)

MINIMUM (3) FASTENERS.(TYPE PER ENGINEERING DESIGN)

NON-SKINNING BUTYL [SL05]

SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)

MINIMUM 2 1/2" BEARING SURFACE

ROOF PANEL

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES

@ PANEL JOINT

CONCEALED FASTENER CLIP @

EACH SUPPORT LOCATION [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

3/32"x1/2" BUTYL TAPE

[SL01]

3/16"x7/8" BUTYL TAPE

[SL02]

SDL-#14X7/8"-HW5/16"-GB9/16"

@ EACH HIGH MESA

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

LOW EAVE TRIM [TR02-01]

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 8" O.C.

3/16"x7/8" BUTYL TAPE [SL02]

WALL PANEL CLIP [CF01]

INSULATED METAL WALL PANEL

Page 11: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

RAKE AT WALL PANEL IMP-106 JAN 6/21 A

1"

VARIES

VARIES

NOTE:

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.

INSULATED METAL WALL PANELSTRUCTURAL SUPPORT

(BY FRAMING SUPPLIER)

3/16"x7/8" BUTYL TAPE [SL02]

SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.

WALL PANEL CLIP [CF01]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

RAKE TRIM [TR03-01]

RAKE CLOSURE ZEE TRIM [TR09-02A - 10']

SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.

1/4"x7/8" BUTYL TAPE[SL03]

ROOF PANEL

IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 12" O/C

RAKE ANGLE

(BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS

SEALANT LINES @ PANEL JOINT

MINIMUM (3) FASTENERS

(TYPE PER ENGINEERING DESIGN)

Page 12: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

STACK JOINT TO HIGH EAVE IMP-107 JAN 6/21 A

6" M

IN

.

18" (M

AX.)

VARIES

V

A

R

IES

NOTE:

- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.

INSULATED METAL WALL PANEL

WALL PANEL CLIP [CF01]

MINIMUM (3) FASTENERS

(TYPE PER ENGINEERING DESIGN)

SD3-#14X1"-PC @ 5'-0" O/C

NON-SKINNING BUTYL [SL05]

SUPPORT ANGLE

(BY FRAMING

SUPPLIER)

STRUCTURAL SUPPORT

GIRT (BY FRAMING

SUPPLIER)

NON-SKINNING BUTYL [SL05]

FIELD INSULATED FILLER INSULATION

(BY OTHERS)

WALL PANEL CLIP [CF01]

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

URETHANE POLYSEAL [SL06]

1/4"x7/8" BUTYL TAPE [SL03]

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

INTERIOR COVER TRIM [TR10-03]

NON-SKINNING BUTYL [SL05]

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]

@ 18" O/C

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

SD3-#14X2 1/2"-HW3/8"

(3 PER CLIP)

STRUCTURAL SUPPORT PURLIN

(BY FRAMING SUPPLIER)

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

CONCEALED FASTENER CLIP @

EACH SUPPORT LOCATION [CF02]

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

COVER TRIM [TR10-01]

1/8"Ø X 1/2" STAINLESS STEEL RIVET @ 12" O/C

HIGH SIDE FLASHING TRIM

[TR08-05-_T]

SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]

@ 6" O.C. OUTSIDE CLOSURE

1/4"x7/8" BUTYL TAPE[SL03]

CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

1/8"Ø X 1/2" STAINLESS STEEL RIVET

@ 18" O/C

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

SUPPORT ANGLE SEALED TO STRUCTURAL

SUPPORT (BY FRAMING SUPPLIER)

Page 13: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

WALL TO HIGH EAVE IMP-107A JAN 6/21 A

VARIES

V

A

R

IES

NOTE:

- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

INSULATED METAL WALL PANEL

WALL PANEL CLIP [CF01]

MINIMUM (3) FASTENERS

(TYPE PER ENGINEERING DESIGN)

SD3-#14X1"-PC @ 5'-0" O/C

NON-SKINNING BUTYL [SL05]

STRUCTURAL SUPPORT GIRT (BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

URETHANE POLYSEAL [SL06]

1/4"x7/8" BUTYL TAPE [SL03]

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

INTERIOR COVER TRIM [TR10-04]

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

HIGH SIDE FLASHING TRIM

[TR08-05-_T]

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

COVER TRIM [TR10-01]

1/8"Ø X 1/2" STAINLESS STEEL RIVET @ 18" O/C

1/4"x7/8" BUTYL TAPE[SL03]

CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]

@ 18" O/C

SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)

STRUCTURAL SUPPORT PURLIN (BY FRAMING SUPPLIER)

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

CONCEALED FASTENER CLIP

@ EACH SUPPORT LOCATION [CF02]

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

Page 14: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

WALL TO ROOF RAKE IMP-108 JAN 6/21 A

VARIES

VARIES

NOTE:

- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

STRUCTURAL SUPPORT (BY FRAMING SUPPLIER)

ROOF/RAKE SUPPORT (BY FRAMING SUPPLIER)

NON-SKINNING BUTYL [SL05]

IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C

URETHANE POLYSEAL [SL06]

INTERIOR COVER TRIM [TR10-04]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

NON-SKINNING BUTYL [SL05]

STRUCTURAL SUPPORT PURLIN

(BY FRAMING SUPPLIER)

SEE CONSTRUCTION DRAWINGS IF ANGLE

IS REQUIRED

SD3-#14X1"-PC @ 5'-0" O/C

MINIMUM (3) FASTENERS

(TYPE PER ENGINEERING DESIGN)

WALL PANEL CLIP [CF01]

INSULATED METAL WALL PANEL

SDL-#14x7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

COVER TRIM [TR10-01]

1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 18" O/C

1/4"x7/8" BUTYL TAPE[SL03]

CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)]

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

WALL TO RAKE FLASHING TRIM

[TR08-04-_T]

1/4"x7/8" BUTYL TAPE[SL03]

Page 15: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

RIDGE DETAIL IMP-109 JAN 6/21 A

VARIES,

SEE CO

N

STRU

CTIO

N

D

RAW

IN

G

S

1" OFFSET ℄

RIDGE TO PANEL

VARIES

V

A

R

IES

EXTERIOR RIDGE CAP [TR11-01]

1/4"x7/8" BUTYL TAPE [SL03]

CONCEALED FASTENER CLIP

@ EACH SUPPORT LOCATION [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

INSULATED METAL

ROOF PANEL

℄ RIDGE

EXPANDABLE FOAM INSULATION

(BY OTHERS)

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

CLOSURE ZEE RIDGE CAP [TR09-02 (42" LONG)],

FILL ALL GAPS WITH URETHANE POLYSEAL [SL06]

NOTE:

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- REDUCE PANEL EXTENSION IN SNOW DRIFT CONDITIONS.

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS SEALANT

LINES @ PANEL JOINT

SD3-#14X2 1/2"-HW3/8" (3 PER CLIP)

STRUCTURAL SUPPORT

(BY FRAMING SUPPLIER)

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS

SEALANT LINES @ PANEL JOINT

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

SD3-#14x1" PC [FST6-3]

@ 60" O/C

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS

SEALANT LINES

@ PANEL JOINT

INTERIOR RIDGE CAP

TRIM [TR11-02-15L]

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

Page 16: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

HIP DETAIL IMP-109A JAN 6/21 A

RUN

RISE

VARIES

2"

(51)

V

A

R

IES

℄ HIP

NOTE:

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

EXTERIOR RIDGE CAP [TR11-01]

1/4"x7/8" BUTYL TAPE [SL03]

CONCEALED FASTENER CLIP

@ EACH SUPPORT LOCATION [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

INSULATED METAL

ROOF PANEL

EXPANDABLE FOAM INSULATION

(BY OTHERS)

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

FIELD FABRICATED ZEE CLOSURE RIDGE CAP.

CUT & NOTCH [TR09-02A - 10'] RAKE ZEE TO FIT

BETWEEN PANEL RIBS (FILL ALL GAPS WITH

URETHANE POLYSEAL [SL06]).

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES

@ PANEL JOINT

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

HIP PLATE

(BY FRAMING SUPPLIER)

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS SEALANT

LINES @ PANEL JOINT

SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)

STRUCTURAL SUPPORT

(BY FRAMING SUPPLIER)

PROVIDE MARRIAGE BEAD BETWEEN

CONTINUOUS SEALANT LINES @ PANEL JOINT

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

Page 17: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

VALLEY DETAIL IMP-110 JAN 6/21 A

1"

9" M

IN

.

3"

3

"

3"

V

A

R

IES

V

A

R

IES

NOTE:

- VALLEY DETAIL DOES NOT APPLY FOR DORMER CONDITIONS.

- VALLEY CONDITIONS ARE NOT RECOMMENDED FOR APPLICATIONS WITH ROOF PITCH LESS THAN 3:12.

- THE VALLEY PAN WIDTH VARIES WITH THE ROOF'S DRAINAGE REQUIREMENTS.

- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.

- RECOMMENDED VALLEY PAN IS 16 GA. MIN. STEEL, WELDED WATER-TIGHT AND COATED OR LINED WITH MEMBRANE.

INSTALLATION SEQUENCE:

1. INSTALL STRUCTURAL VALLEY SUPPORT PLATE.

2. FASTEN VALLEY SUPPORT ZEE E/S TO VALLEY PLATE.

3. FILL VOID WITH INSULATION.

4. INSTALL VALLEY TRIM.

5. INSTALL SEALANTS.

6. FIELD CUT PANEL AND REMOVE CUT BACK.

7. FASTEN VALLEY ASSEMBLY.

INSULATED METAL

ROOF PANEL

FIELD INSTALLED INSULATION

(BY OTHERS)

3/32"x1/2" BUTYL TAPE [SL01]

@ SIDE JOINT

SD3-#14x1"-HW3/8" [FST2-3]

TRIPLE BEAD 3/16"x2 1/2" BUTYL TAPE [SL04]

CONCEALED FASTENER CLIP

@ EACH PANEL SIDELAP [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

INSULATED METAL

ROOF PANEL

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS

SEALANT LINES

@ PANEL JOINT

NON-SKINNING BUTYL [SL05]

STRUCTURAL VALLEY SUPPORT PLATE

(BY FRAMING SUPPLIER)

STRUCTURAL SUPPORT

(BY FRAMING SUPPLIER)

VALLEY PAN TRIM

[TR12-01]

RIGID INSULATION

(BY OTHERS)

3" FIELD CUT BACK

FOAM/ LINER SKIN

VALLEY SUPPORT ZEE

[TR12-02_T]

SD3-#14X1"-PC [FST6-3]

(2) PER CONNECTION

SD3-#14X2 1/2"-HW3/8"

(MIN. 3 PER CLIP)

PROVIDE MARRIAGE BEAD

BETWEEN CONTINUOUS

SEALANT LINES

@ PANEL JOINT

6

4

7

5

3

1

2

MINIMUM ROOF SLOPE FOR VALLEYS:

3" in 12"

Page 18: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

TRANSITION CONT. WALL TO ROOF RAKE IMP-111 JAN 6/21 A

VARIES

SEAL VOID WITH URETHANE POLYSEAL [SL06]

SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]

@ 8" O.C.

COUNTER FLASHING [TR08-03]

SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]

@ 6" O.C.

RAKE TRANSITION TRIM [TR08-02]

CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

INSULATED METAL

ROOF PANEL

1/4"x7/8" BUTYL TAPE[SL03]

CONTINUOUS NON-SKINNING BUTYL [SL05]

3/16"x7/8" BUTYL TAPE [SL02]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C

NON-SKINNING BUTYL [SL05]

ROOF/RAKE SUPPORT ANGLE WITH SEALANT

(BY FRAMING SUPPLIER)

STRUCTURAL EAVE SUPPORT

(BY FRAMING SUPPLIER)

INSULATED METAL WALL PANEL

Page 19: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

TRANSITION CONT. WALL TO HIGH EAVE IMP-111A JAN 6/21 A

V

A

R

IES

VARIES

SEAL VOID WITH URETHANE POLYSEAL [SL06]

COUNTER FLASHING [TR08-03]

SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.

HIGH SIDE TRIM [TR08-01]

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

1/4"x7/8" BUTYL TAPE[SL03]

CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

1/8"Ø X 1/2" STAINLESS

STEEL RIVET [FST4] @ 18" O/C

CONCEALED FASTENER CLIP @

EACH SUPPORT LOCATION [CF02]

3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

SD3-#14X2 1/2"-HW3/8"

(MIN. 2 PER CLIP)

STRUCTURAL SUPPORT

(BY FRAMING SUPPLIER)

CONTINUOUS NON-SKINNING BUTYL[SL05]

3/16"x7/8" BUTYL TAPE [SL02]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

URETHANE POLYSEAL [SL06]

1/4"x7/8" BUTYL TAPE[SL03]

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

INTERIOR COVER TRIM [TR10-03]

1/8"Ø X 1/2" STAINLESS

STEEL RIVET [FST4] @ 18" O/C

NON-SKINNING BUTYL [SL05]

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

INSULATED METAL WALL PANEL

Page 20: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

TRANSITION MASONRY WALL TO HIGH EAVE IMP-112 JAN 6/21 A

V

A

R

IES

SEAL VOID WITH URETHANE POLYSEAL [SL06]

COUNTER FLASHING

[TR08-03]

#14 MASONRY FASTENER

@ 8" O.C.

HIGH SIDE TRIM

[TR08-01]

SDL-#14X7/8"-HW5/16"-GB9/16"

@ 6" O.C. OUTSIDE CLOSURE

1/4"x7/8" BUTYL TAPE[SL03]

CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

1/8"Ø X 1/2" STAINLESS

STEEL RIVET [FST4] @ 18" O/C

CONCEALED FASTENER CLIP @ EACH

SUPPORT LOCATION [CF02]

TWO ROWS OF

NON-SKINNING BUTYL [SL05]

SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)

3/16"x7/8" BUTYL TAPE [SL02]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

URETHANE POLYSEAL [SL06]

1/4"x7/8" BUTYL TAPE[SL03]

11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).

ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.

INTERIOR COVER TRIM

[TR10-03]

PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS

SEALANT LINES @ PANEL JOINT

#14 MASONRY FASTENER @ 18" O/C

NON-SKINNING BUTYL [SL05]

STRUCTURAL EAVE SUPPORT (BY FRAMING SUPPLIER)

ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)

SEAL VOID WITH

URETHANE POLYSEAL [SL06]

COUNTER FLASHING

[CUSTOM]

#14 MASONRY FASTENER

@ 8" O.C.

1/8"x1/2" SAW CUT IN MASONRY.

FILL WITH POLYURETHANE CAULK

BEFORE INSERTING COUNTER

FLASHING.

OPTIONAL COUNTER FLASHING DETAIL

Page 21: PROFILE APPLICATION IMP ROOF PANELS COMMERCIAL - …artspaninc.com/.../ArtspanIMPStandardDetailsRoof.pdf · 2021. 1. 7. · 42" coverage 11 2"1 1 2" 18 " 4" sht. date rev. profile

REV.SHT. DATE

APPLICATIONPROFILE

DETAIL

NOTES:

A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.

B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.

IMP ROOF PANELS COMMERCIAL - INDUSTRIAL

TRANSITION MASONRY WALL TO RAKE IMP-112A JAN 6/21 A

SEAL VOID WITH URETHANE POLYSEAL [SL06]

#14 MASONRY FASTENER @ 8" O.C.

COUNTER FLASHING [TR08-03]

SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]

@ 6" O.C.

RAKE TRANSITION TRIM [TR08-02]

CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)],

FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]

INSULATED METAL ROOF PANEL

NON-SKINNING BUTYL [SL05]

NON-SKINNING BUTYL [SL05]

FIELD INSTALLED FILLER INSULATION

(BY OTHERS)

URETHANE POLYSEAL [SL06]

IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C

NON-SKINNING BUTYL [SL05]

ROOF/RAKE SUPPORT ANGLE WITH SEALANT

(BY FRAMING SUPPLIER)

STRUCTURAL EAVE SUPPORT

(BY FRAMING SUPPLIER)

SEAL VOID WITH

URETHANE POLYSEAL [SL06]

COUNTER FLASHING

[CUSTOM]

#14 MASONRY FASTENER

@ 8" O.C.

1/8"x1/2" SAW CUT IN MASONRY.

FILL WITH POLYURETHANE CAULK

BEFORE INSERTING COUNTER

FLASHING.

OPTIONAL COUNTER FLASHING DETAIL