profile different configurations of industrial battery

7

Upload: others

Post on 12-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Profile Different Configurations of Industrial Battery

Chargers

Salient Features

An Overview

Diversified Product Range

Microcontroller Based Battery Charger

Chloride Power Systems and Solutions Limited, a 100%

Float cum Boost (FCBC)subsidiary of Exide Industries Limited, offers complete DC

Power Solutions for industrial customers. Established in Float and Boost (FC & BC)1980, it is a leading name in the field of power electronics in Dual Float cum Boost (DFCBC)India. Its state-of-the-art facility at Salt Lake Electronics

Application/Customer specific configurationComplex, Kolkata manufactures a wide range of Battery

Chargers and other DC controlling equipment. Chloride also

exports its products to South and South East Asia. They are a

major player in integrated solar system market too. Suitably designed for all types of batteries – Planté,

TBS/OPzS, HR Tubular, Gel Tubular VRLA, AGM

VRLA and Ni-Cad

Microcontroller basedMore than 30 years of experience in Power Electronics Soft StartAn ISO 9001:2008, ISO 14001:2004 & BS OHSAS Battery path limiting current18001:2007 certified company

Automatic Float to Boost changeoverMost trusted name in DC Power Solutions

Operation under reverse input phase sequenceFacilities include PCB soldering facility and computer

aided testing to ensure the highest quality Dropper Diode regulator in load path for specific

applicationApproved by all leading consultants

Insulation class for magnetics as per IS standardApproved by all major end users and utilities

Cabinet fabrication using CNC machines – enamel Nationwide sales & service networkpaint/powder coat as per IS-5

Psosphometr ic noise 4mV for spec i f i c

application/requirement of customerThyristorized Industrial Battery Chargers

Seismic Test CertificationSMPS based Industrial Battery Chargers

Soak Test/ Environmental Test CertificationMicrocontroller based Battery Chargers

DCDB & ACDB

DC-DC ConvertersChloride high end microcontroller based battery chargers

Compartmentalized DCDB Chargersensure optimum life and performance of industrial

Cell Booster storage batteries at power plants, sub-stations, steel Traction Battery Chargers plants, refineries, oil & gas pipelines and telecom

exchanges.Por tab le 12V

CCCV Batter y Key features & benefitsCharger ( HOME Better control and flexibilityCHARGE ) f o r

Complete control automotive and

achieved through i n v e r t e r

programming of the Batteries.

m i c r o c o n t r o l l e r 24/30V compact modulecharger

Using same module, ( CHARGE)

chargers of different for wide range

r a t i ng s c an be of industrial

produced only by applications.

c h a n g i n g t h e Battery softwareMonitoring

For changing the System

c o n t r o l l i n g Integrated Solar pa r ame te r s , no Systems modification or

SMART

readjustment is needed in hardware components Stores data in a suitable memory and uses

intelligent software to ascertain the trend of Provide digital interface which makes the chargers individual cells.intelligent, user friendly and capable of handling

complex requirements Generates audio-visual alarm on identifying

weak cell Voltage and Current setting can be changed

through keypad The system can be

monitored from a

distance of up to 1 Km

t h r o u g h s p e c i a l

C h l o r i d e r e m o t e CBC Chargers have wide applications –power

monitoring software distribution, Switchgear closing tripping for sub-stations,

Battery charging & Emergency Lighting, Telecommunications, Control & discharging current Monitoring systems, Microwave Links & Radio displayed on LCDInstallations, Fire & Security Systems.Remote Scan switch for Key featuresmanual scanning

Integrated system houses both charger and Wall mountablebattery bank in a single cubicle

Main Application AreasDesigned to float Power plants & substationsand boost charge

bo th l e ad a c id Office Automation Equipment(sealed & vented) Steel Plantsand nickel cadmium

Refineries, Chemical and Fertilizer Industriesbatteries in nominal

voltage of 24V &

30V

O p e r a t e s i n EBOPS is an emergency hot standby backup power constant potential supply system mainly used in elevators for all the mode and constant emergency services in the elevator - intercom, lights, fan, current modeemergency alarm, etc.

F u l l y a u t o m a t i c Key featuresoperation

Switches on instantly to battery operated power Long battery life and simplified maintenancewhen AC mains power supply fails

Interchangeable control cardsEBOPS has a pure sine

LEDs to indicate all important charging related wave output

information and monitor faults Sa fe maintenance

Meters on front panel for measuring voltage & m o d e f o r e a s i e r

currentmaintenance

Provides alarm signal

to control room in case

any device connected The Battery Monitoring System (BMS) is a microcontroller to EBOPS output starts based device which continuously monitors and checks malfunctioning the trend of individual cells in a battery bank.

Suitable for both VRLA Key features & non-VRLA batteries

BMS measures individual cell voltage periodically. Minimum changeover time for mains to backup or It also has the option of both manual and auto vice versascanning. Portable, light weight & compact sizeChloride BMS captures various parameters like Batteries housed inside the EBOPS - no extra voltage, current, ambient temperature etc. on an space required for battery installationon-going basis

Integrated CBC Series Standby Power System

Charger

Emergency Board Operated Power Supply

(EBOPS)

Battery Monitoring System (BMS)for Industrial

Storage Battery Bank

Fully automatic operation

Meters on front panel for measuring voltage CHARGE is easy and current to install, commission

LED lamps to indicate all important information and service with wide

and fault monitoring applications - diesel

generator (DG) sets,

substat ions, ser vice

centers, community Chloride is one of the major players in integrated solar

areas and more. An optional LCD display in place of systems under the Capital Subsidy Scheme of

meters is also available.NABARD, which in turn has been enlisted by the SPV

Key featuresDivision of Ministry of New & Renewable Energy. Cont ro l ope ra t ion p rogrammed by Chloride liaises with designers of Solar Lighting microcontroller logicSystems, procures components and builds a fully

integrated system. Application for both 24V and 30V system and

for all VRLA and Flooded lead acid batteriesProduct Range includes:

Facility of both automatic and manual mode Solar PV Modulesoperation Solar Charge controllersPortable, lightweight and compact sizeSolar Inverter Control and interlocking both present in one L u m i n a i r e s control card(CFL & LED) for LCD display (optional feature)So l a r Home

system LEDs to indicate all important charging related

information to the user and any fault indicationL E D b a s e d

s t r e e t Self diagnostic featureluminaires for

solar solutions

Solar Lighting Systems package:HOME CHARGE

1. Solar Home lighting System :The Constant Current

ü LED based Constant Voltage ü CFL based charger is ideal for

a u t o m o t i v e a n d 2. Solar Street Lighting System:i n v e r t e r b a t t e r y ü LED basedd e a l e r s , s e r v i c e

ü CFL basedproviders and users.

3. Solar Lantern: This charger is suitable ü LED based for 12V system and is equipped with a smart LCD

display screen that indicates battery voltage and ü CFL basedcharging. The button can be used to reset all the 4. Solar Power Pack (0.5KWp – 10KWp)displayed parameters on the LCD screen.

5. Solar Power Plant (0.5KWp – 500KWp)Key features

Solar/Renewable Energy Solutions:Easy and fast charging of car/inverter battery in

Solar rooftop systemcase of insufficient/improper charging of the

Solar solution for commercial establishmentssystem

Street /Area lighting system using Solar and LED Portable, light weight and compact size

luminaires Intelligent charging profile

Bank power solutionsEasy trouble shooting due to robust design and

Solar powered school/collegessimple circuit

HospitalsImproved customer satisfaction-by getting real

Other customized solutions time battery information, end user can take

corrective action if necessary

Smart Charger

Integrated Solar Systems

Portable CCCV Battery Charger

( )

SMART

12V Constant Current Discharger

FLEXI CHARGER

E-RICKSHAW CHARGER

minimal time. Ensures long back up from the battery

and also enhances battery life. Taper charging profile This is a specially designed Portable Discharger with a of the charger coupled with two in-built timers unique discharging logic to discharge a 12V battery. eliminates any possibility of overcharging.This discharger uses CC (constant current) mode of

discharging and stops automatically, which avoids

deep discharging. All these features ensure 1. Charging starts at 12 Amps ± 2 Amps and is unattended and safe further reduced to 3-4 Amps when the battery discharging of a lead voltage reaches around 2.6 VPC.acid battery at any

2. Two in-built timers for automatic termination of point of time and at

charging. any place. This is

3. Weight 11.5 kg ± 5%most suitable for

4. Transformer based design.d i s c h a r g i n g a

5. Less electronics components and relatively charged battery at

simple circuitcustomer premises

and can be used at

service station also.

This is a ‘must have Chloride Flexi Charger is a microcontroller based SMPS

equipment’ for the charger. This charger is suitable for charging 1 to 4

dealers of inverter and automotive battery..nos. (12Volts)

This discharger displays all the technical parameters l e a d a c i d like Battery Voltage, Discharging Current, Total AH batter y. The output and Discharging Time in the display panel and selection for no it helps the users service engineers to know the state of battery is of discharge of the battery at a glance. automatic i.e.

1 to 4 sets

12Volts lead Capacity 12V/32A

acid battery. Current regulation +/- 2.5AThe selection

Timer setting range : 1 to 8 hours insteps of 1 for number of

hour separate model for 1to 3 hours.b a t t e r y i s

Battery reverse polarityautomatic i.e. the user may connect any number of

LCD panel at the front displays the following: 12V battery (1 or 2 or 3 or 4 sets 12 Volts batteries)

Total Ah output from battery and no manual selection is needed.

Total Discharging time

Discharging current Capacity 48V/10 A

Battery voltage Automatic selection for number of battery

Termination of charging – Manual

Mode of operation - Automatic

Chloride make LCD display for measurement of charging

E - R i c k s h a w voltage and current

charger ensures Protection - I/P & O/P MCB protection and easy, fast and reverse Polarity Protection.o p t i m u m

charging of the

batter y within

Key Features

Key Features

Key Features

OUR MAJOR CUSTOMERS

"This catalogue is issued to provide outline information only and should not be deemed to form part of an offer or contract. As a process of continuous product improvement policy, the specifications are subject to change without prior notice.".

syne

rgix

/ 0

5, 2

014/

2K

Chloride Power Systems and Solutions Limited (a wholly owned subsidiary of Exide Industries Limited) KOLKATA : Plot No.Y-21, Block-EP, Sector-V, Salt Lake Electronics Complex, Kolkata 700 091, West Bengal, India , Phone Nos. (033) 2357 5851/5852/5853/5854/7841, Fax : (033) 2357 7062, Email : [email protected], Website : www.chloridepowersystems.com, Debasis Saha Mobile No. : +919830125945 Email: [email protected], Santasri Sarma Mobile No. : +919830482288 Email: [email protected], Pranab Dey,‘+91 9051378700, [email protected], Mosharaf Ali Mobile No. : +919051570328 Email: [email protected], Mr.Nelesh Pandit, [email protected], +91 9051260600, Indrajit Bhattacharya Mobile No. : +919674163117 Email : [email protected] Central Service Parthapratim Sahana Mobile No. : +919674163113 Email : [email protected], DELHI: 8/42,Ground floor, Opposite of MDH Spice factory, Kirtinagar Industrial Area, Email : [email protected], [email protected] / [email protected], Ashutosh Rai Mobile No. : +9199115 51626 MUMBAI: Apeejay Chambers, 5, Wallace Street, Fort, Mumbai - 400 001 Phone : 022-22058502 Email : [email protected], Amarnath Mirajkar Mobile No. : +9198337 61222 CHENNAI: Now No. 824/1, Old No 398. 3rd floor Anna Salai, Nandanam, Chennai 600035, Tamilnadu, India Ph: 044 2434 1217, Fax: 044 4907 5126, Isaac Shantharaj Mobile No.: +919444073315 Email : [email protected], BANGALORE: Ware House No. 8, KKSP Complex, 7th Mile, Kudlugate, Hosur Main Road, Bangalore - 560 068, Phone : 080-2574 4353 Email ID : [email protected], Mr. Rahul Kumar Vishwakarma Mobile No. : +919901444665 For Solar enquiries Sanjoy Malash Mobile No. : +9192305 19896 Email: [email protected], Satyabrata Pattanayak Mobile No. : +91 9830440008 Email: [email protected] Website : www.chloridepowersystems.com