1 * Master code # * * Master code # 0 New code # New code # * PROGRAMMING GUIDE. KEYPAD ** For all configurations to be done in the system, we must always fits in programming mode. To enter in programming mode Master Code 888888. (Default factory master code) Press : Exit : To change master code. RECOMMENDED Enter in programming mode: Press : Exit Note : The Master Code must be 6 digits.

Upload: others

Post on 14-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

1

* Master code #*

* Master code #0 New code # New code #*

PROGRAMMING GUIDE. KEYPAD

** For all configurations to be done in the system, we must always fits in programming mode.

To enter in programming mode

Master Code 888888. (Default factory master code)

Press : Exit :

To change master code. RECOMMENDED

Enter in programming mode:

Press :

Exit

Note : The Master Code must be 6 digits.

Page 2: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

2

* Master Code #2 ID Number #

* *

* Master code #1 ID Number # PIN Number # User 1

ID Number # PIN Number # User 2ID Number # PIN Number # User 3

* *

* Numéro de passe #1 Numéro ID # Numéro PIN #

* *

To ad User

* The system can be Program from 2000 user.

* Each user has an identification number ID and each ID has a number from 4 to 8 digits. (1- 99999999), with the exception of 1234, already reserve for the system.

* Example. To the'user 24, he is awarded the PIN number 6543.

ID = 24. PIN = 6543.

VIA PIN A) To add a user via PIN.

Enter in programming mode

:

Press : Exit :

B) To add several user PIN.

Enter in programming mode: Press :

Exit :

* User can be added continuously without exiting programming mode.

To Delete a Pin user

A) To Delete a user via PIN. Enter in programming mode:

Press : Exit :

Page 3: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

3

* Master code #2 ID Number # PIN Number # User 1

ID Number # PIN Number # User 2ID Number # PIN Number # User 3

* *

* Master Code #1 Read Card #*

* Master code #1 ID Number # Read Card #*

B) To Delete several users via PIN.

Enter in programming mode: Press :

Exit :

To Change PIN number use with ID

* Not need enter in programming mode.

To Change PIN number to use Card

VIA USER CARD

A) To add a user with user card. Assignment automatic ID

Enter in programming mode :

Press :

Exit :

B) To add user with user card. ID assignment. With this method an ID number is assigned to a card. A number ID can only be assigned to a card. Enter in programming mode:

Press : Exit :

This method is suggested because in case of loss or theft, by eliminating the ID code, the card is cancelled.

* ID Number # Old PIN Number # New PIN Number # New PIN Number #

* Read Card # Old PIN Number # New PIN Number # New PIN Number #

Page 4: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

4

* Master Code #5 ID Number # 8 Cars Numbers # Given Number to Card #*

Read Add Master Card Read User Card Read Add Master Card

Read Delete Master Card Read User Card Read Delete Master Card

* Master Code #2 Read Card #*

* Master Code #2 ID Number #*

C) To add user with user card. Numbered cards. Enter in programming mode:

Press :

Exit :

The total of authorised cards is from 1 to 2000.

The 8 numbers of the card = 8 last numbers of the card

* Example. ID Number = 24.

8 Numbers of the Cards = 15205261

Given Number = 0001.

D) To Add or delete users VIA Master Card.

To Add.

To Delete.

TO DELETE USERS WITH USER CARDS

A) To Delete user with user card.

Enter in programming mode:

Press :

Exit :

B) To Delete user ( User card with ID, already lost).

Enter in programming mode:

Press : Exit :

Page 5: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

5

* Master Code #2 0000 #*

* Master Code #3 0 #*

* Master code #1 ID Number # Read Card #*

* Read Card Default PIN Number 1234 # New PIN Number # New PIN Number #

C) To delete all users at the same time. Entre in programming mode:

Press : Exit :

Setting the Working mode

There are 3 possible mode.

A) Open only with the user card.

B) Opening by the user card and PIN code.

C) Opening by the user card o by PIN code. ( by default from the factory ).

Open only with the user card.

Enter in programming mode:

Press :

Exit :

Opening by the user card and PIN code

Configuration process to use this work mode.

1* It must be change to working mode “2” see « C « = *888888 # 32 # *

2* Add user via user card.

Enter in programming mode:

Press : Exit :

3* It must change the PIN code of the card user, By default there is the 1234 and may not

be assigned.

To Change PIN Number at User card.

Page 6: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

6

* 888888 # 43 # *

* Master Code #3 1 #*

* 888888 # 31 # *

* Master Code #3 2 #*

* Master Code #4 Select time (seconds) #*

4* Finally it is necessary specify the work mode “1" here under.

Enter in programming mode:

Press : Exit :

To open , read user card and press ID number and press # .

Example of actuation with the number standard password, ID 24 and pin 6543

And continued active the mode of works " 1 "

To open : Read user cars and press 6543 and #.

C) To Open with user card or PIN code. (If not Changed 1234).

Enter in programming mode:

Press : Exit :

MODIFICATION OPENNING TIME Enter in programming mode:

Press : Exit :

Standard time is 5 seconds.

Example to set 3 seconds:

* 888888 # 32 # * * 888888 # 124 # Read card * * Read card 1234 # 6543 # 6543 #

Page 7: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

7

* Master Code #6 0 #*

* Master Code #6 1 #*

Master Code #

Master Code #

DOOR OPEN DETECTION

Door alarm open long time.

If the door uses a detection system of warning from the door open and remains more than 1 minute open, active an internal alarm, if that is programed.

Disable open door detection

Enter in programming mode:

Press : Exit :

Activate open door detection

Enter in programming mode:

Press :

Exit :

Disable Alarm door open.

Can be stop in to ways. Door must be close.

1. Read user card.

2.

Disable Alarm forced door.

Can be stop in to ways. Door must be close.

1. Read user card.

2.

Page 8: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

8

*

*

* Master Code #8 0 #*

* Master Code #8 1 #*

Keypad Sound

Disable Sound.

Enter in programming mode:

Press : Exit :

Activate Sound.

Enter in programming mode :

Press :

Exit :

SYSTEM RESET.

Process to follow to reset to factory default.

1. Power off.

2. Press and hold the key.

3. Hold the key and power on until hear two beeps and the LED shines in yellow.

4. Stop press key.

5. Read Add Master Card. (1 beep)

6. Read Delete Master card. (1 beep and LED in Red)

Reset process finish.

Notice.

* To restore the default configuration of'factory, it retains the information of users

registered with the exception of the information of the cards “master addition and elimination ", for this reason it is essential to make steep " 5 and 6 ".

* * In the case of loss of the Master Card, any card "EM RFID 125 Khz, can perform the functions of master, simply follow the not 5 and 6.

In the case of use of user card as Master Card, it is necessary to identify the cards with the new function.

Page 9: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

9

Wiring

Fail secure Connexion Schema AC .

1 Grenn D0 No opérattionel ( isoler pointe cable ) (wiegand output D0 )2 White D1 No opérattionel ( isoler pointe cable ) (wiegand output D1 )3 grey Alarm Connecting to the negative pole of the alarm equipment.4 Yellow Push button To connect to one part of exit button.5 Brown D_IN Connect switch for the'status of the door (magnetic switch etc.)

12VDc + Connect positif pole to of power supply ( 6902 ) 12V Dc +12VAc Connect pole to Power Supply ( 6901 )

12VDc - Connect negative pole to of power supply ( 6902 ) 12V Dc -12VAc Connect pole to Power Supply ( 6901 )

In VDc Connect to negative pole of open system.In VAc Connect to pole of open system.

9 Purple COM Connect to black wire (negative )In VDc Connect negative pole of open system.In VAc Connect pole of open system.

11 Pink GND (Negative) Connect to the push button inside o switch for the'status of the door.

WIRING

6 Red

7 Black

Notice : NO. Normaly open = Fail Secure. NC. Normaly Close = Fail Safe. If System work with VDc, install le diode IN 4004 keep en respectant la polarity.

8 Blue NO

10 Orange NC

Page 10: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

10

Fail safe Connexion Schema AC .

Fail secure Connexion Schema DC .

Page 11: PROGRAMMING GUIDE . KEYPAD - veiligwonenwinkel.nl€¦ · 3 1 # * * 888888 # 31 # * * Master Code # 3 2 # * * Master Code # 4 Select time (seconds) # * 4* Fin ally it is necessary

11

Fail safe Connexion Schema DC.