progress on coatings and grooves c.yin-vallgren, s.calatroni, p.chiggiato, p.costa pinto,
DESCRIPTION
Progress on coatings and grooves C.Yin-Vallgren, S.Calatroni, P.Chiggiato, P.Costa Pinto, M.Taborelli C based coatings: aging Grooves. Aging of C. Evolution of CNe9 over 1 month. 2h 3d 8d 15d 23d. - PowerPoint PPT PresentationTRANSCRIPT
SPSU05.08.2008
Progress on coatings and grooves
C.Yin-Vallgren, S.Calatroni, P.Chiggiato, P.Costa Pinto, M.Taborelli
-C based coatings: aging-Grooves
SPSU05.08.2008
Evolution of CNe9 over 1 month
0.0
0.2
0.4
0.6
0.8
1.0
1.2
0 500 1000 1500 2000
energy
SE
Y
CNe9_20080630_1
CNe9_20080702_4
CNe9_20080707_1
CNe9_20080714_1
CNe9_20080723_1
CNe9_top_20080714_
2h3d8d15d23d
Aging of C
Slight shift of Emax to lower E, is compatible with higher SEY for surface sensitive, low energy electrons. Same as for contamination coverage of air exposed surfaces of metals
SPSU05.08.2008
Aging for 2 nominally identical samples stored in the lab in air, in sample box
Measurements made repeatedly on the same sample: the air exposure occurs after the sample has received already a doseTypical dose per measurement: 10-7Clb/mm2
Aging of C
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
0 5 10 15 20 25 30 35Time[d]
SE
Y
C-Ne 8 bottom
C-Ne9 top
SPSU05.08.2008
Is there a difference between aging of irradiated and non-irradiated samples?
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
0 10 20 30 40
Time[d]
SE
Y
C-Ne 8 bottom
C-Ne9 top
CNe9_B
CNe9-bottom
One sample measured only once after 1 monthOne sample measured only twice (2h and 1 month)To be studied more in detail
Aging of C
SPSU05.08.2008
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 500 1000 1500 2000
energy
SE
Y
CNe9_RoughZr_20080715_1
CNe9_RoughZr_20080724_1
CNe9_RoughZr_2008
Aging of C on rough Zr: 1 week air
SPSU05.08.2008 1
10
100
1000
104
105
0 5 10 15 20
Particles counted before and after coating3m > D
particles > 5mm
REF measure 1TUBE before coatingREF measure 2TUBE after coating
nu
mb
er
of
pa
rtic
les
run#
1
10
100
1000
104
0 5 10 15 20
Particles counted before and after coatingD
particles > 5m
REF measure 1TUBE before coatingREF measure 2TUBE after coating
nu
mb
er
of
pa
rtic
les
run#
Measure 1Two identical SS tubesMeasured in clean room
TUBE + REF
TUBE coated with carbon
REF remains in the coating lab. (closed with
plastic covers)
Measure 2TUBE + REF
measured again in the clean room
MEASUREMENT OF PARTICLES IN A CARBON COATED TUBE
SPSU05.08.2008
Grooves, calculation of L.Wang at SLAC on the geometryobtained on copper
Progress on grooves
2mm
100 200 300 400 500 600 7000.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
Energy (eV)
SE
Y
0=1.50,Height=1.0mm, =150, B=0
CERN workshop onCopper (S.Atieh, J.M.Geisser)
0 100 200 300 400 500 600 7000.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
Energy (eV)
SE
Y
0=1.50,Height=1.0mm, =15o
B=0.2TeslaB=2 Tesla
B=0
Assuming delta-max=1.51mm
15º
Reduction also for B=0so that we can measure in the lab
B=0.2TB=2T
SPSU05.08.2008
0 200 400 600 8000
0.2
0.4
0.6
0.8
1
1.2
1.4
Energy (eV)S
EY
Grooved SurfaceFlat Surface
0=1.20,B=2 Tesla,R
tip=0.13mm,H=1mm
Measurement on Cu grooves (scan on the sample)
Progress on grooves
Expected decrease (perfect shape: 15° aperture, B=0) : factor 2Expected decrease (20° aperture + radii 0.13 mm, B=2T) : factor 1.3Measured decrease (real shape: 20 °+ radii 0.03 mm, B=0): factor 1.2The difference is possibly due to imperfection of the machined shape
B=2T, 20°, 0.13 mm radii)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0 500 1000 1500 2000
Energy [eV]
SEY
GrCu_20080711_1
GrCu_20080711_2
GrCu_20080711_3
GrCu_20080711_4
GrCu_20080711_5
GrCu_20080711_6
SmCu_20080711_1
SmCu_20080711_2
flat
grooves
SPSU05.08.2008
Progress on grooves
On Stainless steel:- By manufacturing with a shaped cutting tool the bottom of
the valley is rounded and the tips bend- The entire piece bends
grooves
-release material tensions by thermal treatment before machining- Trials in progress with a milling tool, but for the moment is shows to much wear
millingshape tool
SPSU05.08.2008
Plans for SEY instrument
Done:- Retarding system up to -90V to measure low energy part of the SEY curve
Next:-Implement flood gun for conditioning with e-beam
SPSU05.08.2008
Next on coatings:-New SPS liner, aged 15 days (CNe13, starting δmax =1)-More measurements of aging with single measurement on aged sample-layer of CNx
-characterization by Raman (collaboration with the Uni of Cambridge)
Next on grooves:-Improved shape from workshop-Measurements to be done on Al grooves received from M.Pivi
Other-SPS sample to be extracted and measured on 11/8, possibly new C sample inserted on the same day