3. Access Door - Formed alu- minum door secures lens. Hinges open and retained in place with three quarter-turn captive fasteners. 4. Reflector - Electropolished and anodized aluminum reflec- tor, producing asymmetrical light distribution. Lens (S, shown). Fixture with tem- pered Flat Glass Lens (ARC-F) is IDA-Approved TM dark sky friendly. 7. Ballast - A high efficiency, pulse start, core and coil ballast regulates voltage for H.I.D. lamp. Mounted to removable tray for ease of ser- vicing. Consult factory for detailed ballast information. 8. Socket - 4KV Pulse rated porce- lain medium base for H150, or mogul base for all other lamps up to 400w. Socket is pre-wired to ballast at factory. Exterior Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI. Standard exterior colors are White (WH), Black (BK), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Hot Dip Galvanized finish (GV) on all steel parts also available. 1. Fixture Housing - Formed alu- minum houses sealed optics and ballast. 2. Gasketing - Continuous molded silicone gasket provides weatherproofing, dust and insect control at all fixture connections. 41 3 /8" (1052mm) 2 4 3 5 1 Ø 25 5 /8" (650mm) 10 1 /2" (268mm) 12" (306mm) 5. Lamp - One clear, horizontal, ED17 medium-base 150w metal halide; or one clear, ED28 mogul base 250w - 400w metal halide or 200w - 400w ED18 high pressure sodium. Lamp provided by others. 6. Shielding - Clear, tempered glass with minimum wall thickness of 1/8" (3.17mm). Specify Flat Glass Lens (F) or Sagged Glass 6 Arc ® Selux Corp. © 2018 TEL (845) 834-1400 FAX (845) 834-1401 www.selux.us ARC-0118-01 (ss-v3.9) In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Union Made Affiliated with IBEW Local 363 E NRTL Listed (i.e. UL, CSA) Project: Type: Qty: Series Mounting Lamping Finish Voltage ARC Toltec Arm Series: S1 Single 29" Arm Mount S2 Double 29" Arm Mount L1 Single 41" Arm Mount L2 Double 41" Arm Mount Spanner Arm Series: AS1 Single 48" Arm Mount AS2 Double 48" Arm Mount AL1 Single 96" Arm Mount Direct Mount: DM1 Single 21" Direct Mount Metal Halide H150 150w H250 250w H400 400w HPS S200 200w S250 250w S400 400w 120 208 240 277 347 WH White BK Black BZ Bronze SV Silver SP Specify Premium Color Optics F Flat Glass Lens S Sagged Glass Lens Reflector R2 Type II Distribution R3 Type III Distribution 1 Not available with 347V Options PC Photocell FS 1 Single Fusing ARC Series _ Mounting _ Optics _ Reflector _ Lamping _ Voltage _ Options _ Finish Pole Series Options Height Finish _ _ _ ARC-F ARC-S

Upload: lephuc

Post on 16-Apr-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

3. Access Door - Formed alu-minum door secures lens. Hingesopen and retained in place withthree quarter-turn captive fasteners.4. Reflector - Electropolishedand anodized aluminum reflec-tor, producing asymmetricallight distribution.

Lens (S, shown). Fixture with tem-pered Flat Glass Lens (ARC-F) isIDA-ApprovedTM dark sky friendly. 7. Ballast - A high efficiency, pulsestart, core and coil ballast regulatesvoltage for H.I.D. lamp. Mountedto removable tray for ease of ser-vicing. Consult factory for detailedballast information.8. Socket - 4KV Pulse rated porce-lain medium base for H150, ormogul base for all other lamps upto 400w. Socket is pre-wired toballast at factory.Exterior Luminaire Finish -Selux utilizes a high qualityPolyester Powder Coating. AllSelux luminaires and poles arefinished in our Tiger Drylaccertified facility and undergo afive stage intensive pretreatmentprocess where product isthoroughly cleaned, phosphatedand sealed. Selux powder coatedproducts provide excellent saltand humidity resistance as wellas ultra violet resistance forcolor retention. All products aretested in accordance with testspecifications for coatings fromASTM and PCI.Standard exterior colors are White(WH), Black (BK), Bronze (BZ),and Silver (SV). Selux premiumcolors (SP) are available, pleasespecify from your Selux colorselection guide. Hot DipGalvanized finish (GV) on all steelparts also available.

1. Fixture Housing - Formed alu-minum houses sealed optics andballast.2. Gasketing - Continuous molded silicone gasket providesweatherproofing, dust and insectcontrol at all fixture connections.

41 3/8" (1052mm)

24

3

51

Ø 255/8"(650mm)

101/2"(268mm)12"

(306mm)

5. Lamp - One clear, horizontal,ED17 medium-base 150w metalhalide; or one clear, ED28 mogulbase 250w - 400w metal halide or200w - 400w ED18 high pressuresodium. Lamp provided by others. 6. Shielding - Clear, temperedglass with minimum wall thicknessof 1/8" (3.17mm). Specify FlatGlass Lens (F) or Sagged Glass

6

Arc®

Selux Corp. © 2018TEL (845) 834-1400FAX (845) 834-1401www.selux.usARC-0118-01 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alterthe function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Union Made Affiliated with IBEW Local 363 E

NRTL Listed (i.e. UL, CSA)

Project: Type: Qty:

Series Mounting Lamping Finish VoltageARC Toltec Arm Series:

S1 Single 29" Arm MountS2 Double 29" Arm MountL1 Single 41" Arm MountL2 Double 41" Arm Mount

Spanner Arm Series:AS1 Single 48" Arm MountAS2 Double 48" Arm MountAL1 Single 96" Arm Mount

Direct Mount:DM1 Single 21" Direct Mount

Metal HalideH150 150wH250 250wH400 400w

HPSS200 200wS250 250wS400 400w

120208240 277347

WH WhiteBK BlackBZ BronzeSV SilverSP Specify Premium Color

OpticsF Flat Glass LensS Sagged Glass Lens

ReflectorR2 Type II DistributionR3 Type III Distribution

1Not available with 347V

OptionsPC PhotocellFS1 Single Fusing

ARCSeries

_Mounting

_Optics

_Reflector

_Lamping

_Voltage

_Options

_Finish

PoleSeries

OptionsHeight Finish_ _ _

ARC-F

ARC-S

Page 2: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

H.I.D. Lamp Prorate TableHigh Pressure Sodium Metal Halide

WATTAGE FACTOR INITIAL LUMENS WATTAGE FACTOR INITIAL LUMENS 200 1.10 22000 150 0.70 14000 250 1.40 28000 250 1.00 20000 400 2.55 51000 400 2.00 40000

Catalog # ARC-S-R2-1-H250Report # LSI-15414

l Ideal for applications demanding max. spacing.l Maximum candela of 5813 at 60° vertical.l IES classification - Type II Cutoff.

14532907

43605813

Ve r t i c a l P l a n e t h r o u g h M a x C a n d e l a

60°

30°

90°-90°

-60°

-30° 0 1 313 22

Longitudinal Distance in Units of Mounting Height Transverse Distance in Units of Mounting Height

1

0

2

3

1

2

3

444

4

55

.52

.2

51

.05.1

Flat Glass / Type III Reflector / 250w MH

Catalog # ARC-F-R3-1-H250Test # SX-9559-B10

l Precision formed aluminum reflector with specular “kick” reflectors to precisely control distribution.l Maximum candela of 9859 at 70° verticall IES classification - Type III Full Cutoff.l IDA-ApprovedTM dark sky friendly.

24654930

73949859

Ve r t i c a l P l a n e t h r o u g h M a x C a n d e l a

60°

30°

90°-90°

-60°

-30° 0 1 313 22

Longitudinal Distance in Units of Mounting Height Transverse Distance in Units of Mounting Height

1

0

2

3

1

2

3

444

4

55

.5

2

.2

5

1

.05.1

Sagged Glass / Type II Reflector / 250w MH

Height Conversion ChartValues based on 20' mounting heightMounting Height

16'18'20'25'30'

Multiply1.121.051.000.890.82

Arc®

Photometry

Selux Corp. © 2018ARC-0118-02 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

DOWNLOAD IES FILE:http://www.selux.us/fileadmin/us/exterior/ies_file/ARC_IES.zip

DOWNLOAD IES FILE:http://www.selux.us/fileadmin/us/exterior/ies_file/ARC_IES.zip

Page 3: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

Flat Glass / Type II Reflector / 150w MH

Catalog # ARC-F-R2-1-H150Test # LTL-14137l Precision formed aluminum reflector with specular “kick” reflectors to precisely control distribution.l Maximum candela of 10934 at 67° verticall IES classification - Type II Full Cutoffl IDA-ApprovedTM dark sky friendly.

27345467

820110934

Ve r t i c a l P l a n e t h r o u g h M a x C a n d e l a

60°

30°

90°-90°

-60°

-30° 0 1 313 22

Longitudinal Distance in Units of Mounting Height Transverse Distance in Units of Mounting Height

1

0

2

3

1

2

3

444

4

55

.5

21

.05.1.2

Height Conversion ChartValues based on 20' mounting heightMounting Height

16'18'20'25'30'

Multiply1.121.051.000.890.82

Flat Glass Lens combined with Type II Reflector only possible with H150 M.H. lamp.

Selux Corp. © 2018ARC-0118-03 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Arc®

Photometry (cont’d)

DOWNLOAD IES FILE:http://www.selux.us/fileadmin/us/exterior/ies_file/ARC_IES.zip

Page 4: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

L1

DM1

L2 S1 S2

PoleHeight

PoleHeight

28 9/16"(725mm)

AT535-18 AT535-18 AT635-25 AT635-25

40 9/16"(1030mm)

21"(534mm)

57 1/8"(1450mm)

Toltec Arm Series

EPA / Weight of ARC-S1 (with arm) = 1.68 ft2 (0.16 m2) / 45.0 lbs (20.4kg) EPA / Weight of ARC-S2 (with arms) = 3.22 ft2 (0.30 m2) / 87.0 lbs (39.5kg) EPA / Weight of ARC-L1 (with arm) = 2.06 ft2 (0.19 m2) / 47.0 lbs (21.3kg)EPA/Weight of ARC-L2 (with arms) = 3.97 ft2 (0.37 m2) / 91.0 lbs (41.3kg)EPA / Weight of ARC-DM1 (with arm) = 1.61 ft2 (0.15 m2) / 40.0 lbs (18.1kg)

81"(2060mm)

Note: EPA values indicated are for Fixture Head and ArmAssembly indicated. Pole EPA is not included. See last pagefor pole EPA values.

Scale

: 1/8

" = 1'

PC (Photocell) Detail

21/2"(64mm)

3"(76mm)

Optional Photocell

Note: Photocell is available for all pole and armmounting configurations except Direct Mount.

Selux Corp. © 2018ARC-0118-04 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Arc®

Mounting

Page 5: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

Spanner Arm Series

96"(2440mm)

PoleHeight

96"(2440mm)

AT535-25 AT106-30

Scale

: 1/8

" = 1'

Note: EPA values indicated are for Fixture Head and Arm Assembly indicated. Pole EPA is not included. See last page for pole EPA values.

AS1

PoleHeight

48"(1220mm)

AT535-25

EPA / Weight of ARC-AS1 (with arm) = 1.76 ft2 (0.18 m2) / 47.0 lbs (21.3kg) EPA / Weight of ARC-AS2 (with arms) = 3.27 ft2 (0.30 m2) / 92.0 lbs (41.7kg)EPA / Weight of ARC-AL1 (with arm) = 2.41 ft2 (0.22 m2) / 59.0 lbs (26.8kg)

AS2 AL1

Selux Corp. © 2018ARC-0118-05 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Arc®

Mounting (cont’d)

Page 6: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

Toltec Arm Series(L1 shown)

Spanner Arm Series(AS1 shown)

Fitter for mounting to Ø 3 1/2" tenons Cast Aluminum Mounting Bracket secured into double T constructed aluminum arm with integralenclosed wireway

Fitter for mounting to Ø 3 1/2" tenons Ø 1 1/2" (38mm) Twin Aluminum Arms with Ø 3/8"(9.5mm) support rod

Cast Aluminum Arm with integral wire way cover

Direct Mount Mounting(DM1)For side mounting to pole.

1.187" (30.1mm)

Ø .375" (9.5mm) THRU

Ø .562" (14.3mm) THRU 1" (25.4mm)

3" (7

6.2m

m)

R .406" (R 10.3mm)

Mounting Detail

Optional Photocell

Selux Corp. © 2018ARC-0118-06 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Arc®

Arm Construction Details

Page 7: Project: Type: Qty - Selux — USA Plane through Max Candela 0 60 30 -90 90 -60 -30 322 1 01 3 Longitudinal Distance in Units of Mounting Height T r

OverallHeight

Refer to S635, AT535/635, AT64/74, or AT106 Pole specification sheets for construction details, anchorage information and additional options.S635

Round SteppedSteel Pole

AT535 / 635 / 64 / 74 / 106Tapered Aluminum

Poles

24" (610mm)

18" (457 mm)

Stepped Steel Pole (S635) BC6 Standard Base CoverOne-piece cast aluminum

Ø15 3/4"(400mm)

4 5/8" (118mm)

44"(1118mm) 81/8" (205mm)

Ø 6"(153mm)

20 3/8"(518mm)

BC9 Optional Base Cover (AT 635/AT64)Die cast aluminum, two-piece field installable base cover.

81/8" (205mm)

Ø 7" (178mm)

Ø 20 3/8"(518mm)

BC10 Optional Base Cover (AT74) Die cast aluminum, two-piece field installable base cover.

65/8"(168mm)

BC3 Optional Base Cover (AT 535)Die cast aluminum, two-piece field installable base cover.

53/16" (131mm)

Ø 12 7/16"(316mm)

Ø 5"(127mm)

Selux Corp. © 2018ARC-0118-07 (ss-v3.9)

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter thefunction of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Arc®

Pole Information

21.710.719.011.118.815.723.29.413.520.310.413.426.8

70 mph15.87.714.17.813.611.517.26.49.615.07.09.520.0

80 mph12.35.610.85.610.48.713.34.57.111.44.87.015.3

90 mph9.64.28.64.28.16.910.63.25.69.03.45.4 11.7

100 mph7.63.37.03.26.35.58.62.44.47.32.64.2 9.2

110 mphPole Series EPA Information (ft2) HeightBoltCircle OptionsFinish

S635 3 1/2"Diameter Stepped Steel PoleAT535 5" to 3 1/2" Tapered Aluminum PoleAT64 6" to 4" Dia. Tapered Aluminum PoleAT535 5" to 3 1/2" Tapered Aluminum PoleS635 3 1/2"Diameter Stepped Steel PoleAT64 6" to 4" Dia. Tapered Aluminum PoleAT74 7" to 4" Dia. Tapered Aluminum PoleAT535 5" to 3 1/2" Tapered Aluminum PoleAT64 6" to 4" Dia. Tapered Aluminum PoleAT74 7" to 4" Dia. Tapered Aluminum PoleAT635 6" to 3 1/2" Tapered Aluminum PoleAT74 7" to 4" Dia. Tapered Aluminum PoleAT106-188 10" to 6" Dia. Tapered Aluminum Pole

9"81/2"91/2"81/2"9"

91/2"10 1/2"81/2"91/2"10 1/2"93/4"10 1/2"141/4"

16 16 ft.

18 18 ft.

20 20 ft.

25 25 ft.

30 30 ft.

WH WhiteBK BlackBZ BronzeSV SilverSP Specify Premium Color

BC3 Optional Two-Piece Cast Aluminum Base Cover (for AT535 poles only)BC9 Optional Two-Piece Cast Aluminum Base Cover (AT635/AT64 poles only)

BC10 Optional Two-Piece Cast Aluminum Base Cover (for AT74 poles only)

REC GFCI Receptacle with weather proof cover*T35 31/2" Tennon (required for all poles over Ø 3.5” for arm mounting) For Photocell (PC) Option, see p.1

* Weatherproof cover intended for portabletools or other portable equipment connect-ed to the outlet only when attended. Forother requirements please consult factory.

Other pole configurations available, consult factory. EPA Calculations allow for 1.3 Gust Factor See Mounting Pages for Fixture/Arm Weights and EPA info.