proline configuration handbookdonar.messe.de/exhibitor/hannovermesse/2018/t644157/... · 2017. 11....

12
EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK DESIGN WITH CONFIDENCE PROLINE CONFIGURATION HANDBOOK ENGINEERED FOR INDUSTRIAL ENVIRONMENTS FREESTANDING, DISCONNECT, TYPE 12/IP55

Upload: others

Post on 01-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK

DESIGN WITH CONFIDENCE

PROLINE CONFIGURATION HANDBOOKENGINEERED FOR INDUSTRIAL ENVIRONMENTSFREESTANDING, DISCONNECT, TYPE 12/IP55

Page 2: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTIONPROLINE CONFIGURATION HANDBOOK 2

CUSTOM SOLUTIONS WITH STANDARD COMPONENTS Proline features a comprehensive set of standard components and accessories. These standard components can be used to create a custom enclosure uniquely suited to your application. This configuration handbook can be used to review some of our most popular PROLINE accessories options.

HOW TO USE THIS HANDBOOKStep 1: Select

Circle or check the components that you need.

Step 2: SendGive a hardcopy or send a scanned copy of the configuration handbook to your Hoffman representative who will work with you to configure the PROLINE modular enclosure solution that best fits your needs.

FLEXIBILITY AND PROTECTION PROLINE is a robust enclosure solution that provides powerful mounting options and expansion capabilities. Engineered for industrial environments, PROLINE features an innovative modular design which offers users:

QUESTIONS? Have questions about components or configuration? Pages 9 and 10 of this handbook have a brief description of each component. Additional information can be found in the Specifier’s Guide which you can download on the Hoffman web site. Or, feel free to contact one of Hoffman’s enclosure experts who will provide application advice and help you configure your enclosure. Web: http://www.pentairprotect.comEmail: [email protected] - 763 422 2211 Hoffman-INTL - 763 422 2570

• Faster population • Larger mounting panels • More mounting options • More efficient use of interior space • Larger door openings• Easier panel loading • Simple ganging/joining options • Streamlined field modifications • Improved interior access• Reduced freight costs

Select Frame Type Circle Height (mm) Circle Width (mm) Circle Depth (mm) Single-Bay Frame 700 600, 800 600

1400 600, 800 500, 600, 8001600 600,700, 800 400, 500, 600, 8001800 600, 700, 800, 1000 400, 500, 600, 8002000 400, 600, 700, 800, 1000 400, 500, 600, 8002200 600, 700, 800, 1000 500, 600, 800, 900

Double-Bay Frames 700 1200 6001600 1200 400, 500, 600, 8001800 1200, 1600 400, 500, 600, 8002000 1200, 1600 400, 500, 600, 8002200 1200 500, 600, 800

SELECT YOUR FRAME TYPE, HEIGHT, WIDTH AND DEPTH

Page 3: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK 3

ENCLOSURE NEED OVERVIEW

EXTERIOR SOLUTIONS

Select Frame Type Circle Height (mm) Circle Width (mm) Circle Depth (mm) Single-Bay Frame 700 600, 800 600

1400 600, 800 500, 600, 8001600 600,700, 800 400, 500, 600, 8001800 600, 700, 800, 1000 400, 500, 600, 8002000 400, 600, 700, 800, 1000 400, 500, 600, 8002200 600, 700, 800, 1000 500, 600, 800, 900

Double-Bay Frames 700 1200 6001600 1200 400, 500, 600, 8001800 1200, 1600 400, 500, 600, 8002000 1200, 1600 400, 500, 600, 8002200 1200 500, 600, 800

Front Solid Cover Solid Door Window Door Double Door Dress Frame Disconnect Door No Door/Cover

Rear Solid Cover Solid Door Window Door Double Door Dress Frame Disconnect Door No Door/Cover

Left Side* Solid Cover Solid Door Dress Frame No Door/Cover

Right Side* Solid Cover Solid Door Dress Frame No Door/Cover

Options EMC EMC Polycarbonate or

Safety Glass*Left/right determined while looking at front of enclosure

Other ____________________________________________________________________________________________________

Number of Enclosures: ________________________________

Do you need an EMC frame? Yes No

Do you need to join/gang your enclosures? Yes No

Paint Grey* Other________________

*7035 textured light-gray polyester

Environmental Rating : NEMA 12 NEMA 1 Other________________

Project Name: ____________________________Contact Name: ____________________________

Company: _____________________________Contact Information (email/phone): ______________

Solid Door Window DoorSolid Cover Double Door Dress Frame Disconnect Doors

SELECT YOUR FRAME TYPE, HEIGHT, WIDTH AND DEPTH

CIRCLE YOUR FRONT, REAR AND SIDES

Page 4: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTIONPROLINE CONFIGURATION HANDBOOK 4

EXTERIOR SOLUTIONS

INTEGRATED COOLING SOLUTIONS

Cooling Fan and Exhaust Package Nominal Fan Size (mm/in) 100/4 150/6 250/10 EMC option

Top Mount Air Conditioner (BTU/hr) 2200 4000

Sprectracool Slim Fit Air Conditioner(BTU/hr) 1000 6800 1700 8500 3400 13500 5000

SELECT YOUR BASE ACCESSORIES (OPTIONAL)

Solid Gland Plate

Filtered Gland Plate w/Vented Plinth Base Covers

Cable Entry Gland Plate

Frame Floor-Mounting Bracket

Casters Frame Feet

Levelers

Solid Gland Plate EMC

Other

SELECT YOUR TOP/ROOF

Solid Top Vented Top w/Integral Fan Tray

Pagoda Top High Performance Pagoda Exhaust Vent

No Top

Solid Top EMC Vented Top w/integral Fan Tray EMC

High Performance Pagoda Exhaust Vent EMC

Other

SELECT YOUR BASE

Solid Base 100 mm Solid Base

100 mm Plinth Base

Transportation Base

Mobile Base

No Top

Solid Base EMC 100 mm Solid Base EMC

200 mm Plinth Base

Other

Page 5: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK 5

EXTERIOR SOLUTIONS

SELECT YOUR DOOR ACCESSORIES

Door Stop Kit Electrical Interlock (shown)

Thermoplastic Data Pocket (shown)

Folding Shelf (Door)

Door Bar Grid Straps

Other

Mechanical Interlock

Steel Data Pocket

SELECT YOUR EXTERIOR ACCESSORIES

Window Kits

Lifting Eyes

Lifting Angles

Hole Seals (mm) micro 22.5 30.5

Hole Seals (Inch) ½ ¾ 1 1¼ 1½ 2 2½ 3 3 ½ 4

Inch 7.5x5.5 11.5x8 15.5x5.5 15.5x10.5 19.5x8 19.5x13.5 25.5x17.5 31.5x21.5 37.5x25.5

(mm)(191x140)(292x203)(394x140)(394x267)(495x203)(495x343)(648x445)(800x546)(953x445)

Syspend Monitor and Keyboard Arm

Qty Qty

SELECT YOUR HANDLE (OPTIONAL)

Flush Swing Handles Key Inserts

Handle with Screwdriver Defeater

Flush Bezel with Insert

L Handle 7-mm triangle Other

Handle with Keylock Small Flush Bezel with Insert

8-mm triangle

Handle for Padlock 7-mm square Handle with DIN Profile Provision

8-mm square

Small Flush Swing Handle

Double-bit with 3-mm pin

Double-bit insert

INTEGRATED COOLING SOLUTIONS

Cooling Fan and Exhaust Package Nominal Fan Size (mm/in) 100/4 150/6 250/10 EMC option

Top Mount Air Conditioner (BTU/hr) 2200 4000

Sprectracool Slim Fit Air Conditioner(BTU/hr) 1000 6800 1700 8500 3400 13500 5000

Page 6: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTIONPROLINE CONFIGURATION HANDBOOK 6

INTERIOR SOLUTIONS

SELECT YOUR PANEL MOUNT SOLUTIONS (OPTIONAL)

Full Mounting Subpanel

Partial Subpanel Height________

Swing Out Subpanel

Side-Mount Subpanel

Joining Subpanel

Other

Full Mounting Subpanel Conductive

Partial Subpanel Conductive Height________

Swing Out Subpanel Conductive

Side-Mount Subpanel Conductive

Joining Subpanel Conductive

SELECT YOUR RACK OR GRID MOUNT SOLUTIONS (OPTIONAL)

Grid Strap (Pair) Vertical Grid Strap (Pair) Rack Angle (Pair)

One Row Hole Pattern Three Row Hole Pattern 19” 23” 24” Other

Two Row Hole Pattern Metric (mm) 1275 1475 1675 1875 2075

Three Row Hole Pattern Square Hole Tapped Hole

Qty*________________ *Number of pairs

Qty*________________ *Number of pairs

Qty*________________ *Number of pairs

SELECT YOUR HEAVY-DUTY SWING-OUT RACK OPTIONS

Heavy-Duty Swing-Out Rack Frame

Frame Width (mm) 600 700 800Rack Angle Units 10 25 30

34 39 43

Other _______________________

SELECT YOUR RACK PANEL OPTIONS

Rack Panels

Material Aluminum SteelRack Angle Size 19” 23” 24”Rack Angle Units 1 2 3 4

5 6 7 8 9 10 11 12 16

Other _______________________

Heavy-Duty Swing-Out Rack Frame Rack Panels

Page 7: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK 7

INTERIOR SOLUTIONS

SELECT YOUR SHELF/COMPARTMENT (OPTIONAL)

Frame Shelf Pull-Out Shelf Rack-Angle Mounted Drawer

Keyboard Shelf

Keyboard Compartment

Consolet Compartment

SELECT YOUR HIGH PERFORMANCE OPTIONS (OPTIONAL)

Barrier Panel Panel Support Brace Transformer Rails Center Upright Barrier Panel EMC

SELECT YOUR INTERIOR ACCESSORIES (OPTIONAL)

Additional Grounding Kit

Additional Grounding Bar system

Select your LED Light OptionsPower AC DC Switch On/off MotionMounting Screw Magnetic

Door-Activated Light Kit

60mm Busbar System

System Voltage_____ (Voltage, AC or DC)

Wiring configuration __________________(1,2,3,4, or 5 wire system)

Total Current_______

Page 8: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTIONPROLINE CONFIGURATION HANDBOOK 8

SELECT YOUR PANEL CABLE MANAGEMENT OPTIONS (OPTIONAL)

Cable Entry Cabinet (mm)

1600 x 500 1600 x 600 1600 x 800 1800 x 600 1800 x 800 2000 x 500 2000 x 600 2000 x 800 2200 x 500 2200 x 500

PROLINE Vertical Cable Manager

Qty__________

Vertical Cable Manager 1

Qty__________

Vertical Tie-Down Cable Manager

Qty__________

Tie-Down Reducing Bracket

Qty__________

Basket Tray

Qty__________

SELECT YOUR PANEL CABLE MANAGEMENT OPTIONS (OPTIONAL) Universal Power Strip Bracket

Wire Management Rails (set of 20)

D-Ring Cable Managers

(set of 10)

Universal D-Ring Bracket

(set of 10)

8” VELCRO® Cable Wrap

(set of 10)

Qty__________ Qty__________ Qty__________ Qty__________ 12” VELCRO® Cable Wrap

Qty__________

SELECT YOUR PANEL CABLE MANAGEMENT OPTIONS (OPTIONAL) Frame Tie-Down

Bracket (set of 10) Cable Spools

(set of 10) Fiber Management

Spool (set of 4) Strut Cable Rings

(set of 10) Universal Transition

Bracket (set of 8)

Qty__________ Qty__________ Qty__________ Qty__________ Qty__________

CABLE MANAGEMENT SOLUTIONS

Page 9: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK 9

Single-Bay Frame 12 gauge solid steel frame with fully welded corners. Rectangular holes that accommodates the 25 mm DIN standard. EMC options available.Double-Bay Frame Welded back center post. No front center post for easy component installation. EMC options available. Solid Cover Steel cover for front/rear/side with a foam-in place urethane gasket and two grounding studs. EMC options available.Solid Door Steel door with reversible hinge, foam-in-place urethane gasket and two grounding studs. A removable door bar grid strap system is included on doors taller than 700 mm and wider than 400 mm. EMC options available.Window Door Choice of safety glass or polycarbonate window to enable viewing of electronic equipment. A foam-in-place urethane gasket, hidden hinges, and two grounding brackets. Double Door Overlapping doors are used on double-bay frames. Removable door bar grid strap is included on doors taller than 700 mm.Dress Frame Provides a decorative trim when a front door or cover is not used.Disconnect Door Provide a means to mount flange-mount disconnects. Hinged mullion provides unobstructed access to interior, easing equipment installation. Variety of ‘preferred’ cutouts designed for use with many commercially available disconnect switches and circuit breakers from a wide variety of manufacturers including: Rockwell Allen-Bradley, ABB Controls, Eaton Cutler-Hammer, General Electric, Siemens and Schneider. Large cutout options to accommodate larger disconnect switches and larger circuit breaker operating handles. Solid Top Used to close the top opening on an enclosure frame. Has a foam-in place urethane gasket and two grounding studs. Bolts are included to hold the top in place (lifting eyes can be used instead of bolts). EMC options available.Vented Top w/Fan Tray Provides a cooling/ventilation solution. An integral fan tray with three pre-wired and mounted fans provides up to 200-300 CFM of exhaust. The vented top is designed to be used in place of a standard top. Bolts are provided to secure vented top to frame. The enclosure can be lifted with a vented top installed (requires accessory lifting eyes). EMC options available.Pagoda Top Features a drip-proof raised pagoda vent with an integral axial exhaust fan. Double-bay Pagoda Tops have one drip-proof raised pagoda vent opening positioned over one bay that can be oriented for right or left ventilation. Bolts secure pagoda top to frame (lifting eyes can be used instead of bolts).Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous operation without lubrication or service. Cooling fan package includes fan, air filter, composite air plenum, finger guard and grille. Exhuast package includes air filter, filter retainer with integral finger guard and grille. EMC options available.High Performance Pagoda Exhaust Vent Features an integral centrifugal blower mounted in a housing that includes a drip-proof removable hood, wire mesh finger guard, perimeter gasket and terminal block. EMC options available.Spectracool Slim Fit Indoor Air ConditionerTop Mount Air Conditioner Available with cooling capacities of 2200 and 4000 BTU/hr. Equipped with an adjustable thermostat for optimal enclosure temperature regulation. Require no hole cutting or special kits for installation.0mm Solid Base Cover for the base of an enclosure. EMC options available.100 mm Solid Base 100 mm cover for base of enclosure. Side gland plates and drill points for locating optional casters are included. EMC options available. Plinth Base Provides space for cables to enter from below. Consists of four cast aluminum corner supports connected to four 16 gauge steel access panels. A gland plate system must also be used to provide Type 12 protection.Transportation Base Provide safe transportation for frames, from a single bay up to a maximum of 3000 mm (118.11 in.) in a multiple-bay system. Unique design allows ROL-A-LIFT® lifting access from each end. A removable gland plate allows wire access between bases.Mobile Base Extend beyond the front and rear of cabinets to provide enhanced stability. Fastens to the underside of the frame and provides integral mounting of furnished casters. The front and rear top surfaces of the base are trimmed with black rubber mats 3 mm thick. Four non-locking casters provide a load-bearing capacity of 1000 lb. (453.6 kg).Solid Plate Gland Plate Used to seal the bottom of the frame. Consists of a base mounting surface and two adjustable foam-gasketed plates that permit cable entry. The plate can be rotated 180 degrees for front or rear cable entry. EMC options available.

EXTERIOR SOLUTIONS

COMPONENT DESCRIPTIONS

Filtered Gland Plate Used to seal the bottom of the frame. Consists of a mounting base, three adjustable plates for cable entry, a filter and filter retaining rails. Vented plinth base covers are installed in the front and rear openings.Cable Entry Gland Plate Adjustable opening for cable entry is foam-lined to maintain a dust-tight seal. Fits all 100 mm solid base gland openings. Can be used in place of standard solid gland plates furnished with 100 mm solid Base. Frame Floor-Mounting Bracket Provides a structural method of bolting a frame to the floor. Fits all frame sizes. Casters Set of four casters (two locking, two non-locking) that mount directly to the bottom of a frame, 0 mm, or 100 mm solid base (do not use on plinth bases.) Casters elevate the enclosure 110 mm (4.33 in.) when installed. A set of four casters supports a maximum load of 454 kg (1000 lb.). Frame Feet Four die-cast feet for use on the bottom of frames that raise the frame 9 mm.Levelers Four post-type levelers allow adjustment for uneven floors. Can be attached to the bottom of a frame or to a 0-mm solid base. Adjustable for 17 mm to 35 mm height. Ball and socket construction. Four levelers will support a maximum of 453.6 kg (1000 lb.)Flush Swing Handle Ergonomically designed to provide style and function in a low profile. Handle can be installed to rotate either clockwise or counterclockwise and can have a custom logo. Flush Bezel Handle Low profile handle with tool-to-open operating mechanism. Provided with a screwdriver slot insert and can have a custom logo.L Handle Stylish option with key lock and two keys. Can be installed to rotate either clockwise or counterclockwise and can have custom logo.Key Inserts Used with flush bezels. Optional for any solid, window or disconnect door.Door Stop Kit Holds doors open at 130 degrees. Mounts without drilling and includes all necessary mounting hardware.Electrical Interlock Provides positive internal safety lockout on electrical enclosures. When energized, these interlocks prevent the door handle from being turned to open the door.Mechanical Interlock Can be actuated by any PROLINE solid or disconnect door in a multiple-bay enclosure system. Up to ten doors, including window doors, can be interlocked. Meets interlocking requirements established by General Motors, Ford and Chrysler.Thermoplastic Data Pocket Provides a convenient place to store wiring diagrams, operation manuals and other documentation inside the enclosure. Adhesive backed pockets mount inside the solid enclosure cover.Steel Data Pocket Fastens to the bottom of the door. Door Bar Grid Straps(purchased separately) must be used to change the vertical mounting position.Folding Shelf (Door) Mounts to door using the Door Bar Grid Straps (sold separately). Locks in two positions—90 degrees as a shelf and 15 degrees as a writing surface. Also mounts to three-row grid straps, side or back panel, or any flat surface. Holds up to 30 pounds.Door Bar Grid Straps Used to mount accessories to the door. Holds up to 100 pounds.Lifting Eyes Used for lifting enclosure and fastening top accessories to frame. Thread into corner blocks in frame. Set of four.Lifting Angles Designed for overhead lifting in conjunction with shackles and a spreader bar. Angle between the top of the enclosure and the cable or chain must be at least 45°.Hole Seals Seals extra pushbutton holes, conduit openings and knockout openings against dust, dirt, oil and water. Includes oil-resistant gasket.Window Kits Steel Window Kits have an acrylic window and are designed to be used on Type 4 and 12 enclosures. An oil-resistant gasket ensures a water-tight seal around the perimeter of the window and frame.Syspend Monitor and Keyboard Arm Vertical motion pendant arm for mounting a flat screen monitor, keyboard and mouse in industrial environments. Display and keyboard can be raised and lowered with one hand. Supports 6-15 lb. loads with an internal gas spring counterbalance. Toggle lever locks arm in place when repositioned vertically. Arm swivels 340 degrees at monitor end and 180 degrees at mounting end. Display tilts forward 15 degrees and back 45 degrees to reduce glare. Folds up within 5 in. of the enclosure wall when not in use.

Page 10: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTIONPROLINE CONFIGURATION HANDBOOK 10

Full Subpanel Designed to provide maximum panel size and be easy to install. Full subpanels slide into the frame on nylon glide blocks, which support the entire weight of the subpanel. Painted or galvanized.Partial Subpanel Partial subpanels can be positioned vertically in 25 mm increments and also can be positioned at any depth in 25 mm increments using the optional grid straps. Painted or galvanized.Swing-Out Subpanel Allows a front-mounted panel to pivot out of an enclosure frame opening. Spring-loaded pivot post allows for easy installation. Quarter-turn latches provided to secure the swing-out panel in the closed position. Painted or galvanized.Side-Mount Subpanel Side-mounted panels can be installed on the interior sides of frames. The panel and all the hardware needed to attach the subpanels to a frame are included. Painted or galvanized.Joining Subpanel Provides a continuous panel surface in multiple bay enclosures. The joining subpanel is inserted between full subpanels of equal height. It can be installed from front or rear. Holes for grounding and mounting hardware are provided. Painting or galvanized.Grid Straps Grid straps can be used to mount accessories or equipment and also to create an internal grid system to allow flexible mounting capabilities in height, width and depth. Can be mounted front-to-back horizontally across the bottom or sides of the frame; left-to-right horizontally between front-to-back pair or from the sides of the frame; vertically between horizontally mounted grid straps.Vertical Grid Straps Provide a vertical extension of the frame holes in the sides of the frame.Rack Angle Available in 19-, 23- and 24-in. configurations. All Rack Angles have two mounting surfaces that serve as mounts for both rack equipment and rack accessories. Can be mounted directly to the enclosure frame or on grid system straps at almost any depth location. Furnished in pairs. Max. 20 pound (9.1 kg) per rack unit for equipment under 20 inches (508 mm) deep.Heavy-Duty Swing-Out Rack Frame Allows 19 inch rack equipment to pivot out of the enclosure frame for better accessibility. Spring-loaded pivot post makes installation easy. Complies with ANSI/EIA RS-310-D rack-mounting standards. Maximum equipment load is 300 pounds.Rack Panel Available in aluminum and painted steel. All panels are flat with oblong holes positioned at EIA standard spacing. Grounding Kit Allows a PROLINE enclosure to be grounded to VDE specifications. Includes six 12-gauge wires 411 mm (16.19 in.) long with ring terminations and M6 mounting hardware.Grounding Bar System Copper plated grounding bars with M6 and M5 tapped holes provide a common point for grounding equipment. Includes insulated mounting brackets. LED Light Kit Provides interior enclosure lighting with otions for screw mount (UL® compliant) or magnetic mount; AC or DC; on/off switch or motion sensor. Small form factor and low power consumption while providing 900 LM of 6500K light. Door-Activated Light Switch Kit Door-activated switch mounts to the frame and includes mounting hardware.Manual Light Switch Kit Manual switch mounts to the frame and includes mounting hardware.Frame Shelf Mounts to the vertical hole pattern on a frame and provides a stationary surface for equipment.Pull-out Shelf Allows easy access to shelf-mounted devices. mounts to the front and rear frame uprights. Load rating is 110 pounds (50 kg).Rack-Angle Mounted Drawer Steel drawer for 19 inch rack-angle mounting mounts to the front surface of the rack angles. Integral steel box contains the drawer and protects surrounding internal equipment.Keyboard Shelf Keyboard Shelf is reversible, allowing two options for mounting keyboards. Hole and grommet in rear surface of shelf provide keyboard cable access into the enclosure.Keyboard Compartment Self-contained, sealed module that mounts to an accessory front opening. PC keyboard rests on a ball-bearing glide shelf with a soft palm-rest. Seamless foam-in-place gasket on door assures a dust-tight seal. Consolet Compartment Provides sealed compartment for keyboard storage or protection for controls. Hinged door allows easy access to compartment. Door support holds door open at 90 degrees. Foam-in-place gasket on door and gasket around open rear surface extend the UL® and CSA rating to the consolet compartment interior.

Cable Entry Cabinet Facilitate cable entry into the sides of enclosures. Open top and bottom of cabinet provide cable access and a means for managing cable. Closure plates, available as optional accessories, seal the open ends of the cabinet. Front opening of cabinet can be closed with either a hinged solid door or screw-on solid cover. Cabinets have a foam-in-place gasket to maintain environmental integrity.PROLINE Vertical Cable Manager For routing and bundling cable inside PROLINE enclosures. Mounts between frame and rack angle so equipment can be centered or aligned on one side. Latching hinged door on front conceals wiring yet allows easy access. Movable plastic spools or fingers help manage cables.Vertical Cable Manager 1 For routing and bundling cable inside cabinets. Wire form gate hinges open to ease wire routing. Mounts to grid strap or frame in front of rack angles.Vertical Tie-Down Cable Manager Provides mounting holes for D-Rings, spools, universal transition brackets and other accessories (order separately). Includes hardware for mounting to strut and ten VELCRO® cable wraps for fastening cable.Tie-Down Reducing Bracket Provides convenient tie down for vertical or horizontal cable management. Allows front-to-back cable pass through. Supports optional D-Rings and wire management spools. Mounting hardware and ten VELCRO® cable wraps included.Basket Tray Mounts horizontally left-to-right in the frame. Can be installed either at the bottom of the frame or to the mounting strut and can provide an internal cable runway in a row of cabinets. Large 51 x 102 mm (2 x 4 inch) mesh allows cable installers to route cables in or out at any point.Universal Power Strip Bracket Fits in the corner of the frame and facilitates mounting a variety of power strips.Wire Management Rails Features a unique hole pattern that allows either wire ties or fasteners to secure wires in place. Frame-mounting hardware is included. One package contains 20 rails.D-Ring Cable Managers D-Rings, can be used to manage cables horizontally, vertically or as they transition. Snap feature allows easy cable access as well as forming a tightly closed connection. Sold in sets of ten.Universal D-Ring Bracket Mounts D-Ring (order separately) on Vertical Tie-Down Cable Manager, PROLINE, Front-to-Back D-Ring Bracket or grid strap. D-Ring locks into hole provided.VELCRO® Cable Wrap Securely holds cable to cable manager and unfastens easily for cable maintenance. Sold in sets of ten.Frame Tie-Down Bracket Provides an easy means to secure and bundle cables using any of the frame’s rectangular holes. Can be positioned parallel or perpendicular to the frame and needs no tools to install—just push into any hole and twist to fasten. Proper bend radius is easily maintained with the flexible VELCRO® tie-down. Sets of 10.Cable Spools Spools maintain minimum cable radius, direct cable and can be used with rack angles, grid straps, or patch panels for general cable management.Strut Cable Rings Snaps into the strut. Can be positioned vertically or horizontally. Ring snaps open and closed to easily position cables. It can be drawn down to snugly bundle cables. Sold in sets of ten.Universal Transition Bracket Provides support for cable in transitions between horizontal and vertical routing. Mounts to strut, grid strap or Vertical Tie-Down Cable Managers. Can be used with VELCRO® Cable Wrap (order separately).

INTERIOR SOLUTIONS

CABLE MANAGEMENT SOLUTIONS

COMPONENT DESCRIPTIONS

Barrier Panel Designed to be used as a buffer between joined or ganged enclosure systems. When mounted to the enclosure, they maintain enclosure environmental integrity. EMC options available.Panel Support Brace Gives additional support to single- and double-bay panels in heavy loading applications. Minimizes the vibration created by components mounted on the panel. Can be installed on existing systems without removing the panel. Furnished in pairs.Transformer Rails Used to mount heavy components and transformers in the bottom of an enclosure. Slotted to fit the integral mounting holes in the frame.Center Upright Vertical channels that attach to the frame (top and bottom) to facilitate the installation of accessories for 600 mm wide frames and 19-inch rack accessories in wider frames. Furnished in pairs.60-mm Busbar System The innovative design of the 60-mm busbar system reduces wiring time by up to 40 percent and allows power to be easily distributed to multiple components while being touch-safe rated to IP20. Pre-wired adapters and sliding DIN rails, enable components to be placed closer together while reducing the raceway and bending radius space required. With this arrangement, the 60-mm Busbar System consumes up to 25 percent less panel space than traditional wiring.

Page 11: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK 11

FOUR WAYS TO SELECT YOUR PROLINEFa

stFu

lfillm

ent S

peed

Sca

leM

oder

ate

Option 1: SimplePROLINE Preconfigured Industrial Packages

PROLINE Preconfigured Industrial Packages are full-featured, ready-to-use enclosure solutions that make it unnecessary to order each component separately. For convenience, a single part number includes a frame, a solid front door, a rear cover, a top cover, a gland plate, lifting eyes and a full mounting subpanel, so only the side covers need to be ordered separately. The offering is rounded out by a large selection of off-the-shelf accessories. For more information on these pre-configured enclosures refer to the PROLINE Modular Enclosure Solutions Brochure.

Option 2: Standard Configuration Configure from Standard Parts

Build your enclosure from the ground up using standard parts detailed in this Configuration Handbook. Select your frame; then choose your top, base, sides and door(s). Next choose from an array of interior and exterior accessories designed to make your industrial modular enclosure easier to populate and easier to use.

Option 3: Custom ConfigurationConfigure from Standard Parts + Custom Paint + Holes/Cut-outs

Need a specific paint color or custom holes or cut-outs? You can add these requirements to your standard configuration with only a small effect on your first run delivery lead time.

Option 4: ModifiedConfigure from Modified Parts + Custom Paint + Holes/Cut-outs

Need something more unique? We will modify a PROLINE Modular Enclosure to fit your specific application needs. This option includes special dimensions, integrated ventilation or cooling components, custom designed components or other unique requirements you may have. A strong engineering team and a global manufacturing organization support this service across the globe.

TYPE 12 UL®/NEMA/CSA/EEMACIP55 IEC/VDE

FREE FACTORY ASSEMBLY Whether you need a standard preconfigured enclosure or a custom solution, PROLINE enclosures can be assembled at the factory free of charge as part of Hoffman’s unique Assemble-To-Order (ATO) program. Save time and hassle by using this free service offering. • Factory assembly by certified professionals • Preconfigured or custom solutions • No fee • Fast delivery

• Reversible door (single or double)

• Top/roof• Rear cover • Full mounting

subpanel • Gland plate • Lifting eyes

Page 12: PROLINE CONFIGURATION HANDBOOKdonar.messe.de/exhibitor/hannovermesse/2018/T644157/... · 2017. 11. 27. · Cooling Fan and Exhaust Packages Engineered for 50,000 hours of continuous

MEXICO D.F.

REYNOSA

MINNEAPOLIS TORONTO

MT. STERLING

SĀO PAULORIO DE JANEIRO

BETSCHDORF

AACHENHEMEL HEMPSTEAD

MOSCOW

WARSAW

DZIERZONIOW

LAINATE

SKARPNÄCK

STRAUBENHARDT

BANGALORE

DUBAI SHANGHAISHENZEN

HONG-KONG

SHIN-YOKOHAMA

SINGAPORE

BOITUVA

SEOUL

SHENYANGXI´AN

BEIJING

QINGDAO

ISTANBUL

EQUIPMENT PROTECTION PROLINE CONFIGURATION HANDBOOK

Bro-00183 A

Pentair, Hoffman and Design with Confidence are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners.

© 2015 Pentair

EUROPEStraubenhardt, Germany Tel: +49.7082.794.0

Betschdorf, France Tel: +33.3.88.90.64.90

Warsaw, Poland Tel: +48.22.209.98.35

Dzierzoniow, Poland Tel: +48.74.64.63.900

Hemel Hempstead, Great Britain Tel: +44.1442.24.04.71

Lainate, Italy Tel: +39.02.932.714.1

Moscow, Russia Tel: +7.495.926.18.85

Aachen, Germany Tel: +49.2405.40996-0

NORTH AMERICAMinneapolis, MN Tel: +1.763.421.2240

Mexico, D.F. Tel: +52.55.5280.1449

Toronto, Canada Tel: +1.416.289.2770

MIDDLE EAST & INDIADubai, United Arabian Emirates Tel: +971.4.37.81.700

Bangalore, India Tel: +91.80.6715.2001

Istanbul, Turkey Tel: +90.216.250.7374

ASIAShanghai, P.R. China Tel: +86.21.2412.1688

Singapore Tel: +65.6768.5800

Shin-Yokohama, Japan Tel: +81.45.476.0271

Seoul, Korea Tel: +82.2.2129.7755

WWW.PENTAIRPROTECT.COM