Propagation Calibration

TRANSCRIPT

  • 5/26/2018 Propagation Calibration

    1/20www.awe-com.com

    Automatic

    Calibration

    2012 by AWE Communications GmbH

  • 5/26/2018 Propagation Calibration

    2/20

    by AWE Communications GmbH 2

    Contents

    Concept

    Step 1: Measurement Data Import

    Step 2: Measurement Data Assignment

    Step 3: Generation of Calibration Files

    Step 4: Run Automatic Calibration

    Step 5: Verify Accuracy

  • 5/26/2018 Propagation Calibration

    3/20

    by AWE Communications GmbH 3

    Automatic Calibration

    Calibration module allows automatic tuning based on measurement data

    Tuning of model parameters

    Tuning of materials properties

    All propagation models and environments are supported

    Calibration files are required and are generated automatically during wave

    propagation predictions if measurement data is available

    Concept

    Prediction 1 withmeasurement data

    Calibration file 1(*.cal)

    Prediction 2 with

    measurement data

    Calibration file 2

    (*.cal)

    Prediction N withmeasurement data

    Calibration file N(*.cal)

    .

    .

    .

    .

    .

    .

    AutomaticCalibration

    (calibration basedon N differentmeasurement

    routes)

    Best Settingsfor Prediction Model

  • 5/26/2018 Propagation Calibration

    4/20 by AWE Communications GmbH 4

    Model Environment Model approach

    3D Intelligent Ray Tracing Urban, indoor Deterministic

    3D Standard Ray Tracing Indoor Deterministic

    Dominant Path Model Rural, urban, indoor Semi-deterministic

    Empirical / Deterministic Two Ray Model Rural Empirical

    Motley Keenan Model Indoor Empirical

    COST 231 Multi-Wall Modell Indoor Empirical

    Automatic Calibration

    Models, parameters and environments supported

    Concept

  • 5/26/2018 Propagation Calibration

    5/20 by AWE Communications GmbH 5

    Automatic Calibration

    Measurement data is required

    Auto calibration generates best settings for models/materials in order to

    match with measurement data

    If measurement data has limited accuracy, auto calibration will lead to wrong

    results

    Superposed measurements (of several transmitters) are not supported. For

    each transmitter an individual measurement route must be available.

    Measurement data can be either Path Loss (dB) or Power (dBm)

    Preferably using measurement data in ASCII file format

    Using a median filter in order to remove effects due to fast fading before the

    data is imported is recommended

    Step 1: Measurement Data Import

  • 5/26/2018 Propagation Calibration

    6/20 by AWE Communications GmbH 6

    Automatic Calibration

    Import of measurements if coordinates for each measured point are

    available:

    It is an ASCII file expected with one line per measurement value and columns for

    longitude, latitude and measured value

    Open result file in ProMan and use File > Import Data or select File > New

    Measurement File.

    Select first or second radio button in the import dialog (depending if coordinates

    should be converted to another system or not)

    After selecting OK the import starts

    Step 1: Measurement Data Import

  • 5/26/2018 Propagation Calibration

    7/20 by AWE Communications GmbH 7

    Automatic Calibration

    Import of measurements if no coordinates for measured points are

    available:

    It is an ASCII file expected with one line per measurement value and only one

    column

    Open result file in ProMan and use File > Import Data or select File > New

    Measurement File.

    Select third radio button in the import dialog

    After selecting OK a poly line can be drawn on the map and the measurement

    values are assigned to the poly line

    Step 1: Measurement Data Import

  • 5/26/2018 Propagation Calibration

    8/20 by AWE Communications GmbH 8

    Automatic Calibration

    Measurement data can be automatically aligned to a line drawn by the user

    (Edit >Align data along a line)

    Modification of measurement data possible with drawing tools (Edit > Edit

    Data)

    Step 1: Measurement Data Import

  • 5/26/2018 Propagation Calibration

    9/20 by AWE Communications GmbH 9

    Automatic Calibration

    Step 2: Measurement Data Assignment

    The measurement data imported in the step before (*.fpp, *.fpl) has now to

    be assigned to a transmitter (Transmitter dialog, button Measurements)

    Mind the correct settings of power, frequency and antenna pattern

    (orientation, type, gain)

    Only one measurement route (resp.

    file) can be assigned to a

    transmitter

    The measurement file must not

    contain a superposition of

    measurements from different sites

  • 5/26/2018 Propagation Calibration

    10/20 by AWE Communications GmbH 10

    Automatic Calibration

    Calibration files are generated automatically if measurement data was

    assigned to a transmitter

    Calibration files (*.cal) are saved in the result folder defined in project

    settings

    Mind the correct project settings in ProMan:

    Adaptive resolution of prediction models not supported

    Propagation paths must be activated

    Coordinates of measurement data must match to prediction area defined

    in ProMan

    After prediction is completed calibration files will be available on hard disk

    Step 3: Generation of Calibration Files

  • 5/26/2018 Propagation Calibration

    11/20 by AWE Communications GmbH 11

    Automatic Calibration

    Automatic calibration is included in ProMan (Computation > Auto Calibration)

    All selected calibration files have to be computed with the same model and in

    the same environment

    Add calibration files to the list

    Step 4: Run Automatic Calibration

    General Settings allow the

    configuration of threshold,

    etc.

    Model Settings allow the

    configuration of the model

    parameter ranges. These

    settings depend on the modelused.

  • 5/26/2018 Propagation Calibration

    12/20 by AWE Communications GmbH 12

    Automatic Calibration

    Auto Calibration can be started with Start button

    After completion, the results are displayed in a separate window

    The best value for each model parameter is shown (together with the

    number of rays used for calibration of this parameter)

    Statistical evaluation is presented below the results

    Step 4: Run Automatic Calibration

  • 5/26/2018 Propagation Calibration

    13/20 by AWE Communications GmbH 13

    Automatic Calibration

    The optimized parameters determined by the auto calibration module

    have to be entered manually into the project settings in ProMan

    Prediction has to be computed again for consideration of new parameters

    After prediction was recomputed the new results can be compared to

    measurement data

    Evaluation of accuracy with mean valueand standard deviation of difference

    between prediction result and measurement data

    Open prediction result in ProMan and select Edit > Subtract Data >Value and

    select the measurement file in the new dialog box

    The differences are shown on the screen

    Statistical evaluation can be shown with the selectionAnalysis > Information

    Step 5: Verify Accuracy

  • 5/26/2018 Propagation Calibration

    14/20 by AWE Communications GmbH 14

    Automatic Calibration

    Example for indoor environment

    Display of statistics for difference

    Step 5: Verify Accuracy

    Prediction result Measurement data Difference between prediction

    result and measurement data

  • 5/26/2018 Propagation Calibration

    15/20 by AWE Communications GmbH 15

    Automatic Calibration

    Further analysis of results possible

    Probability Density Function (PDF)

    Cumulative Density Function (CDF)

    Step 5: Verify Accuracy

    Probability Density Function (PDF) Cumulative Density Function (CDF)

  • 5/26/2018 Propagation Calibration

    16/20 by AWE Communications GmbH 16

    Automatic Calibration

    Material properties and map data can be calibrated additionally

    The following table shows the type of material data supported for calibration

    depending on the propagation model

    Calibration of Materials / Map Data

    Model Map data calibration

    3D Intelligent Ray Tracing Material properties of indoor walls: Reflection, diffraction and transmission loss

    3D Standard Ray Tracing Material properties of indoor walls: Reflection, diffraction and transmission loss

    Dominant Path Model Clutter classes: AttenuationsEmpirical / Deterministic Two Ray Model Clutter classes: Attenuations

    Motley Keenan Model -

    COST 231 Multi-Wall Model Material properties of indoor walls: Transmission loss

  • 5/26/2018 Propagation Calibration

    17/20 by AWE Communications GmbH 17

    Automatic Calibration

    Material calibration has to be enabled in the calibration GUI

    Range for materials can be defined

    As larger the range as longer the calibration process will take

    Individual materials can be enabled or disabled for calibration

    Calibration of Materials / Map Data

  • 5/26/2018 Propagation Calibration

    18/20 by AWE Communications GmbH 18

    Automatic Calibration

    Material configuration can be done in the calibration GUI by clicking on

    Materials

    Modification of material settings possible with Show & Modify button

    Table shows which materials will be calibrated

    Calibration of Materials / Map Data

    C l b

  • 5/26/2018 Propagation Calibration

    19/20 by AWE Communications GmbH 19

    Automatic Calibration

    Range for optimization can be defined in the frequency depending properties

    dialog

    A larger range means longer computation time

    Calibration of Materials / Map Data

    A i C lib i

  • 5/26/2018 Propagation Calibration

    20/20 by AWE Communications GmbH 20

    Automatic Calibration

    Results of material calibration are also shown at the end

    New material properties can be saved in the indoor/urban database

    automatically

    Calibration of Materials / Map Data