proportional valves · 2020. 4. 16. · proportional valve solenoid coils and electronic valve...

51
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-1 B Proportional Valves Proportional solenoid valves for pressure and flow control

Upload: others

Post on 23-Nov-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-1

B

Proportional ValvesProportional solenoid valves for pressure and flow control

Page 2: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-2

Electro-ProportionalValvesSection Contents

Typical Application Rated FlowModel Pressure bar (psi) L/min (USgpm) Page

Proportional Valve Cartrides – Introduction, Features and Benefits................................................................................ B-3

Proportional Flow Controls, Poppet Type

EPV10 ..............................................350 (5000) ............................................30 (8) ...................................................... B-4

EPV16..............................................280 (4000) ............................................160 (42) .................................................. B-8

Proportional Flow Controls, Spool Type

EFV1-10-O........................................210 (3000) ............................................38 (10) ......................................................B-14

EFV1-10-C ........................................210 (3000) ............................................38 (10) ......................................................B-17

EFV1-12-O........................................210 (3000) ............................................104 (27.5) ................................................ B-20

EFV1-12-C ........................................210 (3000) ............................................77 (20.6) ................................................ B-23

EFV2-12-O ......................................210 (3000) ............................................114 (30) ....................................................B-26

EFV2-12-C........................................210 (3000) ............................................114 (30) ....................................................B-29

Proportional Relief

ERV2-10 ..........................................35 (500) ................................................2,8 (0.75) ..................................................B-32

ERV3-10 ..........................................210 (3000) ............................................0,8 (0.25) ..................................................B-34

ERV1-10 spool type ........................240 (3500) ............................................60 (15) .................................................. B-36

ERV1-16 spool type ........................210 (3000) ............................................132 (35) ................................................ B-38

Proportional Pressure Reducing/Relieving

EPRV2-8 ..........................................35 (500) ..............................................7,6 (2) .................................................... B-40

EPRV1-10 ........................................35 (500) ................................................7,6 (2)...................................................... B-42

EPRV3-10 ........................................210 (3000) ............................................30 (8) ........................................................B-44

EPRV1-16 ........................................35 (500) ................................................38 (10) .................................................... B-46

Slip-In Pilot Control Valves

758 Series Flow Regulator ..............100 (1450) ............................................10 (2.6) ....................................................B-48

758 Series Pressure Regulator........60 (870) ................................................10 (2.6) ....................................................B-50

NoteProportional valve solenoid coilsand electronic valve drivers are cov-ered in section C of this Catalog.

Page 3: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

dling flows from 3,8-60,0L/min (1-15 USgpm) at pressures from 35-210 bar(500-3000 psi). Also avail-able is an ERV1-16 which iscapable of handling flowsfrom 7,6-132 L/min. (2-35USgpm) at pressures from35-210 bar (100-500 psi).

The ERV2-10 is a low flowelectric proportionally con-trolled relief valve similar tothe ERV1-10. This valve israted for flows from 0,2-2,8L/min (0.05-0.75 USgpm)and pressures up to 35 bar(500 psi).

The ERV3-10 is a low flowelectric proportionally con-trolled relief valve similar tothe ERV2-10. This valve israted for flows up to 0,8L/min (0.20 USgpm) andpressures up to 207 bar(3000 psi).

The EPRV2-8 is an electric,proportionally controlled,direct acting spool type,screw-in pressurereducing/relieving valve. It iscapable of handling flowsfrom 0-7,6 L/min (0-2USgpm) at set pressuresfrom 0-22 bar (0-320 psi).

The EPRV1-10 is an electric,proportionally controlled,internally pilot operated,spool type, screw-in pres-sure reducing/relieving valve.It is capable of handlingflows from 0-7,6 L/min (0-2USgpm) at set pressuresfrom 14-35 bar (200-500 psi).Also available is an ERV1-16which is capable of handlingflows from 0-38 L/min (0-10USgpm) at set pressuresfrom 14-35 bar (200-500 psi).

The EPRV3-10 is an electric,proportionally controlled,internally pilot operated,spool type, screw-in pres-sure reducing/relieving valve.It is capable of handling flowsfrom 0-30 L/min (0-8 USgpm)at set pressures from 35-207bar (500-3000 psi).

Vickers proportional pressureand flow control valves are

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-3

B

Electro-ProportionalValvesSection Introduction

This section gives basicspecifications for the com-plete line of Vicker’s screw-inproportional control valves.Its purpose is to provide aquick, convenient referencetool when choosing propor-tional valves or when design-ing a system using thesecomponents.

The EPV10 has several out-standing performance fea-tures which give it a uniqueposition in the screw-in car-tridge valve market. Valvegain linearity, flow forcepressure compensation char-acteristics above 20 bar (300psi) and low internal leakage.

The EPV16 is a proportionallycontrolled two-way poppettype valve. The main poppetamplifies a small flowthrough the pilot circuit andis comparable to a transistor.As the transistor uses smallcurrents to control larger cur-rents, the hydraulic valvetransistor or VALVISTORuses the pilotflow to controlthe main stage flow withservo-like response flow tocontrol.

The EFV1 is a proportionallycontrolled two-way, spooltype flow control valve.Technically the valve is notpressure compensated, butat high differential pressuresit is partially flow force pres-sure compensated.

The EFV2 is a three port,pressure compensated, pro-portional flow control valve.The valve can be used as apriority flow regulator, withregulated flow being sup-plied to port 3 and excessflow being by-passed to port2. If port 2 is blocked thevalve functions as a restric-tive, 2 way, pressure com-pensated flow regulator.

The ERV1-10 is an electric,proportionally controlled,internally pilot operated,spool type screw-in reliefvalve. It is capable of han-

designed to be easily con-trolled by the simplest of DCelectrical devices such as a12 volt battery and a poten-tiometer.

Varying the voltage at thecoil is one of the simplestmeans of control available.Any of the Vickers DC coilswill work on most of thesevalves simply by varying thevoltage between 0 and 75%of the rated coil voltage. Itshould be noted that as theoperating temperature of acoil increases, the solenoidforce decreases. Therefore ifthe voltage is held constantas the coil heats up thenvalve pressure (or flow) willchange.

Electrical current controlswith PWM are recomendedfor all Eaton proportionalvalves.

Closed-loop electrical controlwith feedback from theparameter to be monitoredwill provide the most accu-rate control.

Valve Features andBenefits

• Products in this cataloghave been fatigue tested to one million cycles at 132% or 10 millioncycles at 115% of ratedpressure

• All operating parts arehardened steel, groundand honed for long lifeand low leakage

• Designed for maximumflexibility and minimalspace requirements

• All exposed cartridge sur-faces are zinc dichromateplated to resist corrosion

• Reliable, economical andcompact

• Rated flows up to 160L/min (42 USgpm)

• Optional nose-in, side-outor side-in, nose out flowdirection (EPV16 series)

Coil Features and Benefits

The valves in this catalog areoffered with a choice of twoor three standard voltagesand several types of electri-cal connections. For othercoil ratings and connections,consult your Eaton applica-tions engineer.

• Variety of voltages andterminations

• Coils are interchangeablefor serviceability on theEPV10 and EPV16. Coilsare interchangeable forserviceability on the ERV1-10, EPV1-16, EPRV1-10 and EPRV1-16

• Compact, one-pieceweather-proof encapsu-lated design. Eliminatesneed for extra seals

• An arc suppression diodemolded into the coil isavailable as a standardoption on ERV, EPRV and EFV valves

Fluid Cleanliness

Proper fluid condition isessential for long and satifactory life of hydrauliccomponents and systems.Hydraulic fluid must havethe correct balance of cleanliness, materials, andadditives for protectionagainst wear of compo-nents, elevated viscosity,and inclusion of air.

WARNING

Application ofthese products

beyond published perform-ance specifications maycause valve malfunctionwhich may result in personalinjury and/or damage to the machine.

WARNING

For pressuresover 210 bar

(3000 psi) use steel housing.

Page 4: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-4

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (at port 2) 350 bar (5000 psi)Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)Rated flow 0 - 30 L/min (0 - 8 USgpm)Operating ambient temperature -30° to 90°C (-22° to 194°F)Cavity C-10-2Fluids Anti-wear hydraulic oils with Buna-N seals (standard)

Phosphate esters (non-alkyl) with Viton® seals are available by request Viton is a registered trademark of E.I. DuPont

Weight cartridge only 0,78 kg (1.72 lbs)Filtration 70 - 210 bar (1000 - 3000 psi) Cleanliness code 17/15/12

210+ bar (3000+ psi) Cleanliness code 15/13/11Standard housing materials Aluminum or SteelTypical hysteresis Less than 4% of rated current at 10 bar

pressure drop – Pulse Width Modulated (PWM)Internal leakage 10 cm3 maximum @ 140 bar (2000 psi)

and oil viscosity of 30 cStOil viscosity range 10 - 800 cStNominal supply voltage 12 or 24 VDCThreshold current from 300 - 600 mA (12 VDC)

from 150 - 300 mA (24 VDC)Coil current @ max flow 0.7 amps max @ 24 VDC

1.4 amps max @ 12 VDCRecommended PWM frequency 100 - 200 Hz application dependent, 150 Hz typCoil resistance @ 20°C (86°F) 12V-6.5Ω

24V-25.0ΩPower consumption @ rated current 12V-12.8 watts and 20°C coil temperature 24V-12.8 wattsCartridge seal kit 02-317580 (Buna-N)

EPV10Proportional flow control valve (poppet type)

2

1

1

2

2

1

1

2

Functional Symbol

Sectional View

Description

The EPV10 is a direct act-ing, uni-directional, poppettype, 2-way, 2-position,normally closed propor-tional flow control valve.

Operation

In the de-energized posi-tion, flow is blocked fromport 2 to port 1, with noreverse flow permitted.When energized, flow is

allowed from port 2 to port 1 in direct pro-portion to the currentapplied to the solenoidcoil.

Page 5: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-5

B

Voltage rating12D -12VDC 24D - 24VDC

Manual override option*Blank - No manual override M - Pin type S - Screw type*Manual override is available in two different configurations, either push pin type is used when system pressuredoes not exceed 210 bar (3000 psi). Thescrew type can be used at any systempressure. For details see page B-9.

Design number8

6

5FunctionEPV - Electro-proportionalflow control valve, poppettype

Size 10 - 10 Size

Valve housing materialOmit for cartridge onlyA - AluminumS - Steel Maximum operating pressure for aluminum housing is 210 bar (3000 psi).

3

2

1

Dimensions mm (inch)

Valve is shown with “U” coil. See Section C for coil information. Torque cartridge in housing

A - 47-54 Nm (35-40 ft. lbs)S - 68-75 Nm (50-55 ft. lbs)

41,9 (1.65)

Ø 26,7 (1.05)

131,4 (5.17)

80,5 (3.17)

34,0 (1.34)

Ø 43,5 (1.71) Ø 25,8 (1.01)

Ø 15,80 (0.622)

2

1

0.875"-14 Thd.

Manual override

Opening clearance 2,0 (0.08)

Model Code EPV10

WARNING

The cavity shouldbe machined to

the 14,29 (0.562) maximumdiameter and 36,00 (1.417)maximum depth. (See cavity, page M-12)

WARNING

When using the“Screw Type”

override, care must betaken to return the overrideback to its neutral positionbefore activating the valve.Failure to take this precau-tion may result in personalinjury or damage to themachine.

EPV 10 – * – ** – *** – (*) – * – **

1 865432 7

Port size

CODE PORT SIZE HOUSING NUMBER

Aluminum Steel

3G 3/8” BSPP 876703 02-1751036H SAE 6 876700 –8H SAE 8 876701 –6T SAE 6 – 02-1751008T SAE 8 – 02-175101See section J for housings.

4

Coil/Connector types

CONNECTOR

Blank - No coilW - Leadwire (DC only) 02-361830 02-363310Q - Spade terminals (DC only) 02-361836 02-363311U - DIN 43650 02-361837 02-363321Y - Metri-Pack 150 male* 02-361845 02-363322F - Weather-Pack male 02-361848 02-364328N - Deutsch DT04-ZP 02-361849 02-364329*Preferred Packard connector.

7

Aluminum hous-ings can be usedfor pressures upto 210 bar (3000

psi). Steel housings must beused for operating pressuresabove 210 bar (3000 psi).

Page 6: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-6

Step ResponseData

Flow vs Current

With 10 bar differentialbetween inlet and outlet

A - 210 bar (3000 psi) pressure drop from Port 2 to Port 1

B - 10 bar (150 psi) pressure drop from Port 2 to Port 1

10 20 30 40 50 60 70 80 90 100

10

20

30

0

2

4

6

8

0

A B

10

0.04 0.08 0.12 0.160.00

10

20

30

40

50

Typical current step to provide 50% flow

On stroke 35 msec

Off stroke 16

Time - sec

% Current - mA

Flo

w -

US

gp

mFl

ow

res

po

nse

in %

of

max

flo

w

Flo

w -

L/m

in

10 20 30 40 50 60 70 80 90 100

10

20

30

0

2

4

6

8

0

A B

10

0.04 0.08 0.12 0.160.00

10

20

30

40

50

Typical current step to provide 50% flow

On stroke 35 msec

Off stroke 16

Time - sec

% Current - mA

Flo

w -

US

gp

mFl

ow

res

po

nse

in %

of

max

flo

w

Flo

w -

L/m

in

PerformanceCurvesEPV10

Page 7: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-7

B

Flow vs Pressure Drop

Per % of Input Current

Typical Flow Response

For an amplitude of +_ 40% maximum stroke(center to offset) aboutthe 50% position.

∆P = 10 bar (145 psi)

PerformanceCurvesEPV10

90°

100 Hz10 Hz1 Hz.4 Hz–6

0

–3

135°

45°

A

BAm

plit

ud

e -

dB

Ph

ase

lag

- d

egre

es

Frequency HzA – dBB – Phase Lag

10

20

30

20 40 60 80 100 120 140 160 180 200

wolF

0

2

4

6

8

00

0 1000 2000 3000

- 100% of input current

- 85% of input current

- 72% of input current

- 57% of input current

- 43% of input current

A

B

C

D

E

Pressure drop - psi

Pressure drop - bar

L/min USgpm

90°

100 Hz10 Hz1 Hz.4 Hz–6

0

–3

135°

45°

A

BAm

plit

ud

e -

dB

Ph

ase

lag

- d

egre

es

Frequency HzA – dBB – Phase Lag

10

20

30

20 40 60 80 100 120 140 160 180 200

wolF

0

2

4

6

8

00

0 1000 2000 3000

- 100% of input current

- 85% of input current

- 72% of input current

- 57% of input current

- 43% of input current

A

B

C

D

E

Pressure drop - psi

Pressure drop - bar

L/min USgpm

Page 8: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-8

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure 280 bar (4000 psi) Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) NFPA rated Rated flow 0 to 160 L/min (42 USgpm) Operating media temperature -30° to 90°C (-22° to 194°F) Cavity C-16-3S (undercut) Fluids Antiwear hydraulic oils with Buna-N seals (standard)

Phosphate esters (non-alkyl) with Viton® seals are available by request Viton is a registered trademark of E.I. DuPont

Weight cartridge only 1 kg (2.2 lbs)Filtration 70 - 210 bar (1000 - 3000 psi) Cleanliness code 17/15/12

210+ bar (3000+ psi) Cleanliness code 15/13/11

Standard housing materials Aluminum or steel Typical hysteresis Less than 4% of rated current @ 10 bar

pressure drop – Pulse Width Modulated (PWM) Internal leakage @ 140 bar (2000 psi) EPV16A 50 cm3/min maximum and oil viscosity 30cSt EPV16B 10 cm3/min maximum Oil viscosity range 10 - 800 cSt Nominal supply voltage 12 or 24 VDC Threshold current from 350 - 500 mA (12 VDC)

from 175 - 250 mA (24 VDC) Coil current for maximum flow 0.7 amps @ 24 VDC

1.4 amps @ 12 VDC Recommended PWM frequency 100 -200 Hz application dependent, 150 Hz typ Coil resistance @ 20°C (68°F) 12V-6.5Ω/24V-25.0ΩPower consumption @ rated current 12V-12.8 watts and 20°C coil temperature 24V-12.8 watts Cartridge seal kit 02-154069 (Buna-N)

EPV16 Valvistor®

Proportional flow control valve

Functional Symbols

Sectional View

EPV16-A Side-out, nose-in

1

2

3

1

2

EPV16-A EPV16-B

1

2

2

1

1

2

3

1

2

EPV16-A EPV16-B

1

2

2

1

EPV16-B Side-in, nose-out

1

2

3

1

2

EPV16-A EPV16-B

1

2

2

1

EPV16-A EPV16-B

Description

The EPV16 is a 2-way,normally closed, pressurecompensated, poppettype, screw-in cartridgeelectro-proportional flowcontrol valve.

Operation

“A” style (nose in, side out)- In the de-energized posi-tion this valve remainsclosed from port 1 to port2. When current is appliedto the coil, a controlledincreasing flow will beallowed from port 1 to port2, in proportion to the cur-rent applied.

“B” style (side in, nose out)- in the de-energized posi-tion the valve remainsclosed from port 2 to port1. When current is appliedto the coil, a controlledincreasing flow will beallowed from port 2 to port1. In both examples freereverse flow is allowed inthe opposite direction.

Page 9: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-9

B

Coil/Connector typesCONNECTOR COIL PART NUMBER

12VDC 24VDC

Blank - No coilW - Leadwire (DC only) 02-154072 02-154073Q - Spade terminals (DC only) 02-317154 02-317155U - DIN 43650 02-154070 02-154071Y - Metri-Pack 150 male* 02-308808 02-308809F - Weather-Pack male 02-308810 02-308811N - Deutsch DT04-2P 02-390736 02-391885*Preferred Packard connector.See Section C for coil information.

Design number10

9Voltage rating12D - 12VDC 24D - 24VDC

Manual override optionBlank - No manual override M - Pin type S - Screw type*Manual override is available in two differ-ent configurations, either push pin type isused when system pressure does notexceed 210 bar (3000 psi). The screw typecan be used at any system pressure.

8

7

M - Pin type manualoverride option

S - Screw type manualoverride option

Model Code EPV16

FunctionEPV - Electro-proportionalflow control valve, poppettype

Size 16 - 16 Size

Flow directionA - Nose-in, side-out B - Side-in, nose-out

Rated flow @ 10 bar ∆P04 - 40 L/min (10.5 USgpm) 06 - 60 L/min (16 USgpm) 10 - 100 L/min (26 USgpm) 16 - 160 L/min (42 USgpm)

Valve housing materialOmit for cartridge only A - Aluminum S - Steel

5

4

3

2

1

WARNING

When using the “Screw Type” override, caremust be taken to return the override back to its

neutral position before activating the valve. Failure to takethis precaution may result in personal injury or damage tothe machine.

CAUTION

A separate check valve is required down streamto isolate the EPV valve from load forces when

the EPV is used to hold a load.

Aluminum hous-ings can be usedfor pressures upto 210 bar (3000

psi). Steel housings must beused for operating pressuresabove 210 bar (3000 psi).

EPV 16 – * – ** – * – *** – *** – * – * – **

1 9 10865432 7

Port Size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

Aluminum SteelEPV16-A EPV16-B EPV16-A EPV16-B

4G 1/2” BSPP 02-185448 02-166607 02-180050 02-1655006G 3/4” BSPP 02-185449 02-161582 02-180051 02-16493110H SAE 10 02-185446 02-170238 – –12H SAE 12 02-185447 02-166609 – –10T SAE 10 – – 02-180048 02-16198312T SAE 12 – – 02-180049 02-1619825C CETOP5 (NFPA D05) Interface (Requires steel body)See section J for housings.

6

Page 10: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-10

Dimensions EPV16-A

EPV16-A

Nose-in, side-outmm (inch)

Note

When stand alone housingsare used, the followingguidelines apply:

• EPV16-A: Port 3 is to beplugged.

• EPV16-B: Port 3 is to be connected to port 1 in order to provide therequired feedback flow path.

Valves are shown with “U” coil. See Section C for coil information.

Torque cartridge in aluminum housing 108-122 Nm (80-90 ft. lbs)

Torque cartridge in steel housing 136-149 Nm (100-110 ft. lbs)

27,3 (1.07)

(7.12)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

Ø 43,5 (1.71)

Ø 25,4 (1.00)

1.312" -12 Thd.

2

138,1 Hex (1.50)

2

1

With manual actuator No manual actuator

1

2

Screw type actuator (shown) 3 mm hex socket

27,3 (1.07)

181,0 (7.12)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

Ø 43,5 (1.71)

Ø 25,4 (1.00)

1.312" -12 Thd.

2

138,1 Hex (1.50)

2

1

With manual actuator No manual actuator

1

2

Screw type actuator (shown) 3 mm hex socket

27,3 (1.07)

181,0 (7.12)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

Ø 43,5 (1.71)

Ø 25,4 (1.00)

1.312" -12 Thd.

2

138,1 Hex (1.50)

2

1

With manual actuator No manual actuator

1

2

Screw type actuator (shown) 3 mm hex socket

27,3 (1.07)

181,0 (7.12)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

Ø 43,5 (1.71)

Ø 25,4 (1.00)

1.312" -12 Thd.

2

138,1 Hex (1.50)

2

1

With manual actuator No manual actuator

1

2

Screw type actuator (shown) 3 mm hex socket

Page 11: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-11

B

Dimensions EPV16-B

EPV16-B

Side-in, nose-outmm (inch)

Required external connection with standardC-16-3S cavity

For EPV16-B (flow 2 to 1), Port 3 must be connected to Port 1 externally to the cartridge,either by passages in the cavity block or external plumbing. When purchased with undercutbody, this connection is included in the body and Port 3 is not machined. A separate external port connection is not required for EPV16-A (flow 1 to 2).

3

181,0 (7.12)

Ø 43,5 (1.71)27,3 (1.07)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

1.312"-12 Thd.

Ø 25,4 (1.00)

Ø 28,6 (1.12) 38,1 Hex (1.50)

1

3

2

With manual actuator No manual actuator

1

2

1

2

3

Screw type actuator (shown) 3 mm hex socket

3

181,0 (7.12)

Ø 43,5 (1.71)27,3 (1.07)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

1.312"-12 Thd.

Ø 25,4 (1.00)

Ø 28,6 (1.12) 38,1 Hex (1.50)

1

3

2

With manual actuator No manual actuator

1

2

1

2

3

Screw type actuator (shown) 3 mm hex socket

3

181,0 (7.12)

Ø 43,5 (1.71)27,3 (1.07)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

1.312"-12 Thd.

Ø 25,4 (1.00)

Ø 28,6 (1.12) 38,1 Hex (1.50)

1

3

2

With manual actuator No manual actuator

1

2

1

2

3

Screw type actuator (shown) 3 mm hex socket

3

181,0 (7.12)

Ø 43,5 (1.71)27,3 (1.07)

124,7 (4.90)

67,9 (2.67)

185,3 (7.29)

129,0 (5.07)

1.312"-12 Thd.

Ø 25,4 (1.00)

Ø 28,6 (1.12) 38,1 Hex (1.50)

1

3

2

With manual actuator No manual actuator

1

2

1

2

3

Screw type actuator (shown) 3 mm hex socket

Page 12: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-12

Dimensions EPV16

EPV16-A-**-S-5C-**-D-(*)-*-12CETOP 5 Interfacemm (inch)

P A B Ta Tb

P A B TaTb

Ø 6,96/6,85 thru 4 holes

Ø 6,96/6,85 thru 4 holes

11,7 (0.46)

11,7 (0.46)

A

P

B

TaTb

A

P

B

TaTb

99,5 (3.92)219,7 (8.65)

276,0 (10.9) Required for removal

99,5 (3.92)71,6 (2.82)

60,0 (2.38)51,0

(2.01)

60,0 (2.38) 51,0

(2.01)

69,5 (2.74)

71,6 (2.82)

69,5 (2.74)

219,7 (8.65)276,0 (10.9) Required for removal

.250-20 UNC x 2.500" socket head cap screw

(Bolt Kit 255634) M6 x 60 socket head cap

screw (Bolt Kit 689623)

.250-20 UNC x 2.5" socket head cap screw (Bolt Kit 255634) M6 x 60 socket head cap screw (Bolt Kit 689623)

22,8 (0.89)

22,8 (0.89)

ISO-4401-AC-05-4-A (NFPA D05) mounting surface

ISO-4401-AC-05-4-A (NFPA D05) mounting surface

P A B Ta Tb

P A B TaTb

Ø 6,96/6,85 thru 4 holes

Ø 6,96/6,85 thru 4 holes

11,7 (0.46)

11,7 (0.46)

A

P

B

TaTb

A

P

B

TaTb

99,5 (3.92)219,7 (8.65)

276,0 (10.9) Required for removal

99,5 (3.92)71,6 (2.82)

60,0 (2.38)51,0

(2.01)

60,0 (2.38) 51,0

(2.01)

69,5 (2.74)

71,6 (2.82)

69,5 (2.74)

219,7 (8.65)276,0 (10.9) Required for removal

.250-20 UNC x 2.500" socket head cap screw

(Bolt Kit 255634) M6 x 60 socket head cap

screw (Bolt Kit 689623)

.250-20 UNC x 2.5" socket head cap screw (Bolt Kit 255634) M6 x 60 socket head cap screw (Bolt Kit 689623)

22,8 (0.89)

22,8 (0.89)

ISO-4401-AC-05-4-A (NFPA D05) mounting surface

ISO-4401-AC-05-4-A (NFPA D05) mounting surface

EPV16-B-**-S-5C-**-D-(*)-*-12CETOP 5 Interfacemm (inch)

Note

CETOP 5 Seal Kit 02-319667

Page 13: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-13

B

Performance CurvesEPV16

GHI140

120

100

80

60

40

20

0

Pressure Differential - bar

Pressure Differential - psi

280

260

240

220

200

180

160

140

120

100806040200

–0 –500

Flo

w %

*Fl

ow

%*

* Flow interims of % for each poppet size

Command Current, mA

COMMAND SIGNAL

FLOW RESPONSEDelayDelay

TIME

100%90% Reach time90% Reach time

90%

100%

10%0

Off stroke valve response time

On stroke valve response time

0

* Flow interims of % for each poppet size

–150

0

–200

0

–250

0

–300

0

–350

0

–400

0

ABC

D

E

F

140

120

100

80

60

40

20

0100 200(24V) 300 400 500 600 700200 800 1000 1200 1400(12V) 400 600

A

B

CDE

150

150

UPPER TOLERANCE OF FLOW

NOMINAL FLOW (LOWER TOLERANCE)

GHI140

120

100

80

60

40

20

0

Pressure Differential - bar

Pressure Differential - psi

280

260

240

220

200

180

160

140

120

100806040200

–0 –500

Flo

w %

*Fl

ow

%*

* Flow interims of % for each poppet size

Command Current, mA

COMMAND SIGNAL

FLOW RESPONSEDelayDelay

TIME

100%90% Reach time90% Reach time

90%

100%

10%0

Off stroke valve response time

On stroke valve response time

0

* Flow interims of % for each poppet size

–150

0

–200

0

–250

0

–300

0

–350

0

–400

0

ABC

D

E

F

140

120

100

80

60

40

20

0100 200(24V) 300 400 500 600 700200 800 1000 1200 1400(12V) 400 600

A

B

CDE

150

150

UPPER TOLERANCE OF FLOW

NOMINAL FLOW (LOWER TOLERANCE)

GHI140

120

100

80

60

40

20

0

Pressure Differential - bar

Pressure Differential - psi

280

260

240

220

200

180

160

140

120

100806040200

–0 –500

Flo

w %

*Fl

ow

%*

* Flow interims of % for each poppet size

Command Current, mA

COMMAND SIGNAL

FLOW RESPONSEDelayDelay

TIME

100%90% Reach time90% Reach time

90%

100%

10%0

Off stroke valve response time

On stroke valve response time

0

* Flow interims of % for each poppet size

–150

0

–200

0

–250

0

–300

0

–350

0

–400

0

ABC

D

E

F

140

120

100

80

60

40

20

0100 200(24V) 300 400 500 600 700200 800 1000 1200 1400(12V) 400 600

A

B

CDE

150

150

UPPER TOLERANCE OF FLOW

NOMINAL FLOW (LOWER TOLERANCE)

Typical pressure compensation

Typical metering performance

Step response definition of terms

COMMAND CURRENT

12V 24V

A– 600 mA 300mAB– 700 mA 350mAC– 800 mA 400mAD– 900 mA 450mAE– 1000 mA 500mAF– 1100 mA 550mAG– 1200 mA 600mAH– 1300 mA 650mAI– 1400 mA 700mA

PRESSURE DIFFERENTIAL

A– 10 bar 150 psiB– 20 bar 300 psiC– 50 bar 700 psiD– 100 bar 1500 psiE– 200 bar 3000 psi

PRESSURE DROP @ 120 L/MIN (30 USGPM)

On Stroke Off StrokePressure Delay/ Delay/drop ∆P Reach 90% Reach 90%

20 bar (290 psi) 24 ms/35ms 5 ms/15 ms100 bar (1450 psi) 24 ms/17ms 5 ms/7ms

Page 14: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-14

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi) Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated maximum flow at 160 PSID Flow rating “A” 15.1 L/min (4 USgpm)

Flow rating “B” 30.2 L/min (8 USgpm)Flow rating “C” 37.9 L/min (10 USgpm)

Hysteresis 1 USgpm with 400Hz PWM driverLeakage (fully closed) 197 cm3/min (12 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)Recommended PWM frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-10-3Seal kit 9900225-000 (Buna-N)

9900226-000 (Viton®)Viton is a registered trademark of E.I. DuPont

EFV1-10*-0Proportional flow controlvalve, normally open, spool type

Functional Symbol

Profile View

1

2

3

2

3

1

1

2

3

2

3

1

Note

Port 1 is unused and mustbe plugged.

Description

The EFV1-10*-0** is a nor-mally open, unidirectional,uncompensated, spooltype, two way, proportionalflow control, screw-in car-tridge valve.

Operation

The valve is controlled bycurrent supplied to the coil.At zero current, the valve isfully open from port 2 toport 3. At 1500 to 1600 mA(12V coil) the valve is fullyclosed. Port 1 is used forpressure balancing thespool and armature andmust be blocked in allcases.

The maximum intendedpressure drop is 300 PSID.At pressure drops above300 PSID, almost noincrease in flow is obtained.The intended flow directionis from port 2 to port 3.Operation of the valve withflow from port 3 to port 2will produce flow vs currentand flow vs pressure dropcurves that are significantly

different from thoseobtained with flow fromport 2 to port 3.

Since the spool and arma-ture are pressure balanced,

the operating pressuredoes not affect the operat-ing characteristics of thevalve. The operating pointof the valve is determinedonly by current, pressuredrop and temperature.

Page 15: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-15

B

PerformanceCurvesEFV1-10*-0 Cartridge Only

Max. Flow vs Pressure Drop Flow rating "A" (Valve fully open)

mp

gS

U-

wolF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L

-w

olF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

mp

gS

U-

wolF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L

-w

olF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

mp

gS

U-

wolF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L

-w

olF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

Max. Flow vs Pressure Drop Flow rating "B" (Valve fully open)

Max. Flow vs Pressure Drop Flow rating "C" (Valve fully open)

Note

To determine operatingcharacteristics for the flowrating selected, at a specificdifferential pressure, firstdetermine maximum flowfrom upper curve at the dif-ferential pressure value.This will be the “100%flow” flow on the lowercurve.

Parameters: 400 Hz PWM

Flow vs. Current

0

25

50

75

100

0 200 400 600 800 1000 1200 1400 1600

%w

ol F

Current - mA

Page 16: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-16

Model Code EFV1-10-O

FunctionEFV1 - Electro ProportionalFlow Control Valve

Size 10 - 10 Size

SealsN - Buna-N V - Viton

®

Logic0 - Normally Open

4

3

2

1

EFV1 – 10 * – 0 * * – * *** – *****E** – 00

1 9 10865432 7

Flow RatingA - 4 USgpm @ 160 PSIDB - 8 USgpm @ 160 PSIDC - 10 USgpm @ 160 PSID

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

Coil Model Code*E-Series Coils See Section C.

* These model digits will not be stampedon the valve.

Special Features00 - None(Only required when valvehas special features, omittedif ”00.“)

10 9

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block – A 03B Aluminum, Light Duty 02-173358

3/8” BSPP06T Aluminum, Light Duty 566162

SAE 602G Aluminum, 1/4” BSPP 876705 03G Aluminum, 3/8” BSPP 876714 06H Aluminum, SAE 6 876704 08H Aluminum, SAE 8 876711

S 02G Steel, 1/4” BSPP 02-175127 03G Steel, 3/8” BSPP 02-175128 06T Steel, SAE 6 02-175124 08T Steel, SAE 8 02-175125

Note: Both the manifold and port plug are required.

87

32,0(1.26) 19,1 (0.75)

32,8 (1.29)

44,2 (1.74)

86,4(3.40)

64,0(2.52)

47,2(1.86)

2

3

1

108,7(4.28)

Note: EFV1-10 with DIN-43650 connectorshown.

Note - S type manual override shown

Dimensionsmm (inch)

Torque cartridge in housing

S - 68-75 Nm(50-55 ft. lbs)

A - 47-54 Nm(35-40 ft. lbs)

Note: Port 1 is unused and must be plugged.

Page 17: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-17

B

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi) Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated maximum flow at 160 PSID Flow rating “A” 15.1 L/min (4 USgpm)

Flow rating “B” 30.2 L/min (8 USgpm)Flow rating “C” 37.9 L/min (10 USgpm)

Hysteresis 1 USgpm with 400Hz PWM driverLeakage (fully closed) 197 cm3/min (12 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)Recommended PWM frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-10-3Seal kit 9900225-000 (Buna-N)

9900226-000 (Viton®)Viton is a registered trademark of E.I. DuPont

EFV1-10*-CProportional flow controlvalve, normally closed,spool type

Functional Symbol

Profile View

12

3

2

3

1

12

3

2

3

1

Note

Port 1 is unused and mustbe plugged.

Description

The EFV1-10*-C** is a nor-mally closed, unidirectional,uncompensated, spooltype, two way, proportionalflow control, screw-in car-tridge valve.

Operation

ThThe valve is controlled bycurrent supplied to the coil.At zero current, the valve isfully closed from port 3 toport 2. At 1500 mA (12Vcoil) the valve is consideredfully open. This is the maxi-mum intended current levelfor use in applications. Port1 is used for pressure bal-ancing the spool and arma-ture and must be blocked inall cases.

The maximum intendedpressure drop is 300 PSID.At pressure drops above300 PSID, almost noincrease in flow is obtained.The intended flow directionis from port 3 to port 2.Operation of the valve withflow from port 2 to port 3will produce flow vs currentand flow vs pressure dropcurves that are significantly

different from thoseobtained with flow fromport 3 to port 2.

Since the spool and arma-ture are pressure balanced,the operating pressuredoes not affect the operat-ing characteristics of thevalve. The operating pointof the valve is determinedonly by current, pressuredrop and temperature.

Page 18: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-18

PerformanceCurvesEFV1-10*-CCartridge Only

Max. Flow vs Pressure Drop Flow rating "A" (Zero Current)

mp

gS

U - w

olF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L -

wolF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

mp

gS

U - w

olF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L -

wolF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

mp

gS

U - w

olF

02

420

30

40

50

60

10

0

6

8

10

12

14

16

nim/L -

wolF

0 50 100 150 200 250 300Pressure Drop - PSID

0 6.9 20.7

Pressure Drop - bar

10.3 13.8 17.23.4

Max. Flow vs Pressure Drop Flow rating "B" (Zero Current)

Max. Flow vs Pressure Drop Flow rating "C" (Zero Current)

Note

To determine operatingcharacteristics for the flowrating selected, at a specificdifferential pressure, firstdetermine maximum flowfrom upper curve at the dif-ferential pressure value.This will be the “100%”flow on the lower curve.

Parameters: 400 Hz PWM

Flow vs. Current

0

25

50

75

100

0 200 400 600 800 1000 1200 1400 1600

% w

olF

Current - mA

Page 19: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-19

B

Model Code EFV1-10-C

FunctionEFV1 - Electro ProportionalFlow Control Valve

Size 10 - 10 Size

SealsN - Buna-N V - Viton

®

LogicC - Normally Closed

4

3

2

1

EFV1 – 10 * – C * * – * *** – *****E** – 00

1 9 10865432 7

Flow RatingA - 4 USgpm @ 160 PSIDB - 8 USgpm @ 160 PSIDC - 10 USgpm @ 160 PSID

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

Coil Model Code*E-Series Coils See Section C.

* These model digits will not be stampedon the valve.

Special Features00 - None(Only required when valvehas special features, omittedif ”00.“)

10 9

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block – A 03B Aluminum, Light Duty 02-173358

3/8” BSPP06T Aluminum, Light Duty 566162

SAE 602G Aluminum, 1/4” BSPP 876705 03G Aluminum, 3/8” BSPP 876714 06H Aluminum, SAE 6 876704 08H Aluminum, SAE 8 876711

S 02G Steel, 1/4” BSPP 02-175127 03G Steel, 3/8” BSPP 02-175128 06T Steel, SAE 6 02-175124 08T Steel, SAE 8 02-175125

Note: Both the manifold and port plug are required.

87

32,0(1.26) 19,1 (0.75)

32,8 (1.29)

44,2 (1.74)

86,4(3.40)

64,0(2.52)

47,2(1.86)

2

3

1

108,7(4.28)

Note - S type manual override shown

Dimensionsmm (inch)

Torque cartridge in housing

S - 68-75 Nm(50-55 ft. lbs)

A - 47-54 Nm(35-40 ft. lbs)

Note: Port 1 is unused and must be plugged.Note: EFV1-10 with DIN-43650 connectorshown.

Page 20: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-20

EFV1-12*-0Proportional flow controlvalve, normally open, spool type

1

2

344,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Functional Symbol

Profile View

Description

The EFV1-12*-0** is a normally open, unidirection-al, uncompensated, spooltype, two way, proportionalflow control, screw-in cartridge valve.

Operation

The valve is controlled bycurrent supplied to the coil.At zero current, the valve is fully open from port 2 toport 3. At 1500 to 1600 mA(12V coil) the valve is fullyclosed. Port 1 is used forpressure balancing the spooland armature and must beblocked in all cases.

The maximum intendedpressure drop is 300 PSID.

At pressure drops above300 PSID, almost noincrease in flow is obtained.The intended flow directionis from port 2 to port 3.Operation of the valve withflow from port 3 to port 2will produce flow vs currentand flow vs pressure dropcurves that are significantlydifferent from thoseobtained with flow fromport 2 to port 3.

Since the spool and arma-ture are pressure balanced,the operating pressuredoes not affect the operat-ing characteristics of thevalve. The operating pointof the valve is determinedonly by current, pressuredrop and temperature.

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi)Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated maximum flow at 300 PSID Flow rating “A” 95 L/min (25.0 USgpm)

Flow rating “B” 104 L/min (27.5 USgpm)Hysteresis 1 USgpm with 400Hz PWM driverLeakage (fully closed) 77 - 483 cm3/min (5 - 30 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)Recommended PWM frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-12-3Seal kit 9900171-000 (Buna-N)

9900172-000 (Viton®)Viton is a registered trademark of E.I. DuPont

Note

Port 1 is unused and mustbe plugged.

Page 21: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-21

B

Performance CurvesEFV1-12*-0

Cartridge Only

Max. Flow vs Pressure DropFlow rating ”A“ (Zero Current)

0

25

50

75

100

0 200 400 600 800 1000 1200 1400 1600

Flo

w %

Current - mA

0

5

10

15

20

25

30

0 200 400 600 800 1000 1200 1400 1600Current - mA

Flo

w -

US

gp

mFl

ow

- U

Sg

pm

0

5

10 40

60

80

100

20

0

15

20

25

30

Flo

w -

US

gp

m

Flo

w -

L/m

in

0

5

10

15

20

25

30

0 50 100 150 200 250 300Pressure Drop - PSID

0 50 100 150 200 250 300Pressure Drop - PSID

0 10 20Pressure Drop - bar

155

40

60

80

100

20

0

Flo

w -

L/m

in

40

60

80

100

20

0

Flo

w -

L/m

in

0 10 20Pressure Drop - bar

155

0

25

50

75

100

0 200 400 600 800 1000 1200 1400 1600

Flo

w %

Current - mA

0

5

10

15

20

25

30

0 200 400 600 800 1000 1200 1400 1600Current - mA

Flo

w -

US

gp

mFl

ow

- U

Sg

pm

0

5

10 40

60

80

100

20

0

15

20

25

30

Flo

w -

US

gp

m

Flo

w -

L/m

in

0

5

10

15

20

25

30

0 50 100 150 200 250 300Pressure Drop - PSID

0 50 100 150 200 250 300Pressure Drop - PSID

0 10 20Pressure Drop - bar

155

40

60

80

100

20

0

Flo

w -

L/m

in

40

60

80

100

20

0

Flo

w -

L/m

in

0 10 20Pressure Drop - bar

155

0

25

50

75

100

0 200 400 600 800 1000 1200 1400 1600

Flo

w %

Current - mA

1600

40

60

80

100

20

0

Flo

w -

US

gp

m

Flo

w -

L/m

in

0

5

10

15

20

25

30

300 0 50 100 150 200 250 300Pressure Drop - PSID

20

40

60

80

100

20

0

Flo

w -

L/m

in

40

60

80

100

20

0

Flo

w -

L/m

in

0 10 20Pressure Drop - bar

155

Max. Flow vs Pressure DropFlow rating ”B“ (Zero Current)

Flow vs Current

Parameters:400 Hz PWM

Note

To determine operatingcharacteristics for the flowrating selected, at a specificdifferential pressure, firstdetermine maximum flowfrom upper curve at the dif-ferential pressure value.This will be the “100%flow” flow on the lowercurve.

Page 22: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-22

EFV1 – 12 * – 0 * * – * *** – *****E** – 00

1 2 4 5 6 73 8 109

Model Code EFV1-12-O

FunctionEFV1 - Electro ProportionalFlow Control Valve

Size 12 - 12 Size

SealsN - Buna-N V - Viton®

Logic0 - Normally Open

4

3

2

1 Flow RatingA - 25.0 USgpm @ 300 PSIDB - 27.5 USgpm @ 300 PSID

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block –A 04G Aluminum, 1/2” BSPP 02-161817

06G Aluminum, 3/4” BSPP 02-16181610T Aluminum, SAE 10 02-16064212T Aluminum, SAE 12 02-160646

S 04G Steel, 1/2” BSPP 02-16981506G Steel, 3/4” BSPP 02-16981410T Steel, SAE 10 02-16107012T Steel, SAE 12 02-169816

Note: Both the manifold and port plug are required.

87

Coil Model Code*E-Series Coils See Section C.

* These model digits will not be stampedon the valve.

9

Dimensionsmm (inch)

Torque cartridge in housing

S - 136-149 Nm (100-110 ft. lbs)

A - 108-122 Nm (80-90 ft. lbs)

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

10

Note

EFV1-12 with DIN-43650connector shown.

Note

Port 1 is unused and mustbe plugged.

Page 23: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-23

B

EFV1-12*-CProportional flow controlvalve, normally closed,spool type

12

3

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Functional Symbol

Profile View

Description

The EFV1-12*-C** is anormally closed, unidirec-tional, uncompensated,spool type, two way, pro-portional flow control,screw-in cartridge valve.

Operation

The valve is controlled bycurrent supplied to the coil.At zero current, the valve isfully closed from port 3 toport 2. At 1500 mA (12Vcoil) the valve is consideredfully open. This is the maxi-mum intended current levelfor use in applications. Port 1 is used for pressurebalancing the spool andarmature and must beblocked in all cases.

The maximum intendedpressure drop is 300 PSID.At pressure drops above300 PSID, almost noincrease in flow is obtained.The intended flow directionis from port 3 to port 2.Operation of the valve withflow from port 2 to port 3will produce flow vs currentand flow vs pressure dropcurves that are significantlydifferent from those

obtained with flow fromport 3 to port 2.

Since the spool and arma-ture are pressure balanced,the operating pressure doesnot affect the operatingcharacteristics of the valve.The operating point of thevalve is determined only bycurrent, pressure drop andtemperature.

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi)Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated maximum flow at 300 PSID Flow rating “A” 55L/min (14.3 USgpm)

Flow rating “B” 77 L/min (20.6 USgpm)Hysteresis 1 USgpm with 400Hz PWM driverLeakage (fully closed) 77 - 483 cm3/min (5 - 30 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)Recommended dither frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-12-3Seal kit 9900171-000 (Buna-N)

9900172-000 (Viton®)Viton is a registered trademark of E.I. DuPont

Note

Port 1 is unused and mustbe plugged.

Page 24: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-24

Performance CurvesEFV1-12*-C

Cartridge Only

Max. Flow vs Pressure DropFlow rating ”A“ (Valve fully open)

0

5

10

150 105

0 50 100 150 200

Pressure Drop - PSID

Pressure Drop - bar

Flo

w -

US

gp

mFl

ow

- U

Sg

pm

Flo

w %

0

5

10

15

20

25

0 50 100 150 200

Pressure Drop - PSID

Flo

w -

US

gp

m

0

5

10

15

Current - mA

0

25

50

75

100

0 200 400 600 800 1000 1200 1400Current - mA

0 200 400 600 800 1000 1200 1400

10

0

50

Flo

w -

L/m

in

100

Flo

w -

L/m

in

2030405060708090

20

30

40

10

0

50

Flo

w -

L/m

in

20

30

40

0 105Pressure Drop - bar

200

Flo

w %

0

5

10

15

20

25

0 50 100 150 200

Pressure Drop - PSID

Flo

w -

US

gp

m

0

25

50

75

100

1400Current - mA

0 200 400 600 800 1000 1200 1400

10

0

50

Flo

w -

L/m

in

100

Flo

w -

L/m

in

2030405060708090

20

30

40

10

0

50

Flo

w -

L/m

in

20

30

40

0 105Pressure Drop - bar

0

5

10

150 105

0 50 100 150 200

Pressure Drop - PSID

Pressure Drop - bar

Flo

w -

US

gp

mFl

ow

- U

Sg

pm

Flo

w %

0

5

10

15

20

25

0 50 100 150 200

Pressure Drop - PSID

Flo

w -

US

gp

m

0

5

10

15

Current - mA

0

25

50

75

100

0 200 400 600 800 1000 1200 1400Current - mA

0 200 400 600 800 1000 1200 1400

10

0

50

Flo

w -

L/m

in

100

Flo

w -

L/m

in

2030405060708090

20

30

40

10

0

50

Flo

w -

L/m

in

20

30

40

0 105Pressure Drop - bar

Max. Flow vs Pressure Drop Flow rating ”B“ (Valve fully open)

Flow vs Current (Flow rating ”B“)

Parameters:400 Hz PWM

Note

To determine operatingcharacteristics for the flowrating selected, at a specificdifferential pressure, firstdetermine maximum flowfrom upper curve at the dif-ferential pressure value.This will be the “100%”flow on the lower curve.

Page 25: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-25

B

Model Code EFV1-12-C

Dimensionsmm (inch)

Torque cartridge in housing

S - 136-149 Nm (100-110 ft. lbs)

A - 108-122 Nm (80-90 ft. lbs)

EFV1 – 12 * – C * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 109

FunctionEFV1 - Electro ProportionalFlow Control Valve

Size 12 - 12 Size

SealsN - Buna-N V - Viton®

LogicC - Normally Closed

4

3

2

1 Flow RatingA - 14.3 USgpm @ 300 PSIDB - 20.6 USgpm @ 300 PSID

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block N/AA 04G Aluminum, 1/2” BSPP 02-161817

06G Aluminum, 3/4” BSPP 02-16181610T Aluminum, SAE 10 02-16064212T Aluminum, SAE 12 02-160646

S 04G Steel, 1/2” BSPP 02-16981506G Steel, 3/4” BSPP 02-16981410T Steel, SAE 10 02-16107012T Steel, SAE 12 02-169816

Note: Both the manifold and port plug are required.

87

Coil Model Code*E-Series Coils See Section C.

* These model digits will not be stampedon the valve.

9 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

10

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Note: EFV1-12 with DIN-43650 connector shown.

Note

Port 1 is unused and mustbe plugged.

Page 26: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-26

EFV2-12*-0Proportional flow controlvalve, normally open, pressure compensatedspool type

3

-C

2 3

EFV2-12-0

1

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

RegulatedFlow

ExcessFlow

Inlet

Functional Symbol

Sectional View

Description

The EFV2-12*-0 is a nor-mally open, three port,pressure compensated,proportional flow controlvalve. The valve can beused as a priority flow regu-lator, with regulated flowbeing supplied to port 3and excess flow being by-

passed to port 2. If port 2 isblocked the valve functionsas a restrictive, 2 way, pres-sure compensated flow reg-ulator.

Operation

Current supplied to the coilcontrols the valve. At zerocurrent, the valve is fullyopen from port 1 to port 3.At 1600 mA (12V coil) thevalve is fully closed. Thevalve will regulate flow outof port 3 regardless of

downstream system pres-sure. As current is increasedto the solenoid the flow outof port 3 will decrease.

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi)Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated Flow “A” Spool – Max. Regulated flow (By-Pass Mode): 53L/min (14.0 USgpm)

Max. Regulated flow (2 Port Mode): 42L/min (11.0 USgpm)Max. Input flow: 114L/min (30.0 USgpm)

“B” Spool – Max. Regulated flow (By-Pass Mode): 38L/min (10.0 USgpm)Max. Regulated flow (2 Port Mode): 31L/min (8.0 USgpm)

Max. Input flow: 114L/min (30.0 USgpm)Note: Max Regulated Flow may decrease slightly during compensation.

Hysteresis 1.5 USgpm max with 400Hz PWM driverLeakage (fully closed) 240 cm3/min (15 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully open valve 350 ± 100mA (12V coil), 175 ± 50 mA (24V coil)Current to fully close valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)Recommended PWM frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-12-3Seal kit 9900171-000 (Buna-N)

9900172-000 (Viton®)Viton is a registered trademark of E.I. DuPont

Page 27: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-27

B

Performance CurvesEFV2-12*-0

Cartridge Only

Regulated Flow vs PressurePort 3 Pressure > Port 2 Pressure

PSI40003500300025002000150010005000

Regulated Flow vs. Pressure PREG>PBYP

0 amps 0.3 amps 0.6 amps0.9 amps 1.2 amps 1.5 amps

GPM15.0

12.5

10.0

7.5

5.0

2.5

0.0

Regulated Flow vs. Pressure PREG<PBYP

A

BC

D

E F

A B CD E F

PSI40003500300025002000150010005000

Regulated Flow vs. Pressure PREG>PBYP

0 amps 0.3 amps 0.6 amps0.9 amps 1.2 amps 1.5 amps

GPM15.0

12.5

10.0

7.5

5.0

2.5

0.0

PSI40003500300025002000150010005000

Regulated Flow vs. Pressure PREG<PBYP

GPM15.0

12.5

10.0

7.5

5.0

2.5

0.0 F

A

BC

D

E F

A B CD E F

0 amps 0.3 amps 0.6 amps0.9 amps 1.2 amps 1.5 amps

A B CD E F

A

B

CD

E

Flow

(GPM

)

By-Pass Mode

By-Pass Mode

2 Port Mode

2 Port Mode

Current (Milli-amps)

Flow

(GPM

)

16

14

12

10

8

6

4

2

0

16

14

12

10

8

6

4

2

0

Current (Milli-amps)

Regulated Flow vs PressurePort 2 Pressure > Port 3 Pressure

Flow vs Current - A Spool

Parameters:400 Hz PWM

Flow

(GPM

)

By-Pass Mode

By-Pass Mode

2 Port Mode

2 Port Mode

Current (Milli-amps)

Flow

(GPM

)

16

14

12

10

8

6

4

2

0

16

14

12

10

8

6

4

2

0

Current (Milli-amps)

Note: Pressure Compensation curves are shown for “B” spool valves.

Flow vs Current - B Spool

GPM GPM

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(PS

I)

302520151050

400350

300250200

150

10050

012.510.07.55.02.50.0

180

150

100

50

0

AB

GPM GPM

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(PS

I)

302520151050

400350

300250200

150

10050

012.510.07.55.02.50.0

180

150

100

50

0

AB

Pressure Drop Port 1 to Port 2 Pressure Drop Port 1 to Port 3

Page 28: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-28

EFV2 – 12 * – 0 * * – * *** – *****E** – 00

1 2 4 5 6 73 8 109

Model Code EFV2-12-O

FunctionEFV2 - Electro ProportionalFlow Control Valve

Size 12 - 12 Size

SealsN - Buna-N V - Viton®

Logic0 - Normally Open

4

3

2

1 Flow RatingA - 14 USgpm @ 180 PSIDB - 10 USgpm @ 180 PSIDSee specifications

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block –A 04G Aluminum, 1/2” BSPP 02-161817

06G Aluminum, 3/4” BSPP 02-16181610T Aluminum, SAE 10 02-16064212T Aluminum, SAE 12 02-160646

S 04G Steel, 1/2” BSPP 02-16981506G Steel, 3/4” BSPP 02-16981410T Steel, SAE 10 02-16107012T Steel, SAE 12 02-169816

Note: Both the manifold and port plug are required.

87

Coil Model Code*E-Series Coils See Section C.

* These model digits will not be stampedon the valve.

9

Dimensionsmm (inch)

Torque cartridge in housing

S - 136-149 Nm (100-110 ft. lbs)

A - 108-122 Nm (80-90 ft. lbs)

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

10

Note

EFV2-12 with DIN-43650connector shown.

Page 29: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-29

B

EFV2-12*-CProportional flow controlvalve, normally closed,spool type

1

2 3

EFV2-12-C

2 3

EFV2-12-0

1

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Functional Symbol

Profile View

Description

The EFV2-12*-C is a nor-mally closed, three port,pressure compensated,proportional flow controlvalve. The valve can beused as a priority flowregulator, with regulatedflow being supplied toport 3 and excess flowbeing by-passed to port 2.

If port 2 is blocked thevalve functions as a restric-tive, 2 way, pressure com-pensated flow regulator.

Operation

Current supplied to the coilcontrols the valve. At zerocurrent, the valve is fullyclosed from port 1 to port 3.At 1500 to 1600 mA (12Vcoil) the valve is fully open.

The valve will regulate flowout of port 3 regardless ofdownstream system pres-sure. As current isincreased to the solenoidthe flow out of port 3 willincrease.

RATINGS AND SPECIFICATIONS

Performance data is typical with DTE 24 hydraulic fluid at 120°FTypical application pressure 210 bar (3000 psi)Cartridge endurance rating 1 million cyclesCartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)Rated Flow “A” Spool – Max. Regulated flow (By-Pass Mode): 57L/min (15.0 USgpm)

Max. Regulated flow (2 Port Mode): 53L/min (14.0 USgpm)Max. Input flow: 114L/min (30.0 USgpm)

“B” Spool – Max. Regulated flow (By-Pass Mode): 38L/min (10.0 USgpm)Max. Regulated flow (2 Port Mode): 31L/min (8.0 USgpm)

Max. Input flow: 114L/min (30.0 USgpm)Note: Max Regulated Flow may decrease slightly during compensation.

Hysteresis 1.5 USgpm max with 400Hz PWM driverLeakage (fully closed) 240 cm3/min (15 in3/min) at 3000 PSIDAmbient operating temperature -30° to 90°C (-22° to 194°F)Maximum oil temperature 120°C (248°F)Maximum internal coil temperature 200°C (392°F)Nominal supply voltage 12/24 VCurrent to fully open valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)Current to fully close valve 350 ± 100 mA (12V coil), 175 ± 50 mA (24V coil)Recommended dither frequency 200 - 400 HzCoil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)Mass Cartridge only 0,37 kg (0.82 lb)

Cartridge with coil and end nut 0,73 kg (1.62 lb)Fluid All general purpose hydraulic oils such as:

MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.Filtration Cleanliness code 18/16/13Cavity C-12-3Seal kit 9900171-000 (Buna-N)

9900172-000 (Viton®)Viton is a registered trademark of E.I. DuPont

Page 30: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-30

Performance CurvesEFV2-12*-C

Cartridge Only

Flow vs Pressure DropExcess flow P1 to P2 (P3 to Atm)Full current (1700 mA on a 12V Coil)

302520151050

400350300250200150100500

Flow-US gpm

Pres

sure

Dro

p ps

i

17.515.012.510.07.55.02.50.0

180

150

100

50

0

Flow-US gpmPr

essu

re D

rop

- psi

A

B

Flow vs Pressure DropRegulated flow P1 to P3 (P2 to Atm)Full current (1700 mA on a 12V Coil)

Regulated Flow vs PressureRegular to Bypass

3500300025002000150010005000

A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPSD - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPSG - 2.0 AMPS

20.017.515.012.510.07.55.02.50.0

Flow

-US

gpm

Pressure - psi

A

B

C

D

E

G

F

0

2

4

6

8

10

12

14

16

18

0 200 400 600 800 1000 1200 1400 1600 1700

Current (mA)

Flow

(GPM

) By-Pass Mode

By-PassMode

2 PortMode

2 Port ModeA

B

3500300025002000150010005000

20.017.515.012.510.07.55.02.50.0

Flow

-US

gpm

A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPSD - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPSG - 2.0 AMPS

Pressure - psi

AB

C

D

EF

G

Regulated Flow vs PressureBypass to Regular

Flow vs Current

A - A spoolB - B spool

Note: Pressure Compensation curves are shown for “B” spool valves.

A - A spool pressure dropB - B spool pressure drop

Page 31: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-31

B

Model Code EFV2-12-C

Dimensionsmm (inch)

Torque cartridge in housing

S - 136-149 Nm (100-110 ft. lbs)

A - 108-122 Nm (80-90 ft. lbs)

EFV2 – 12 * – C * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 109

FunctionEFV2 - Electro ProportionalFlow Control Valve

Size 12 - 12 Size

SealsN - Buna-N V - Viton®

LogicC - Normally Closed

4

3

2

1 Flow RatingA - 15 USgpm @ 180 PSIDB - 10 USgpm @ 180 PSIDSee Specifications

Bleed Screw andManual Override0 - No core tube special

featuresS - Screw-in type manual

override

6

5

Material PortCode Code*

Description Part Number

0 000 No manifold block N/AA 04G Aluminum, 1/2” BSPP 02-161817

06G Aluminum, 3/4” BSPP 02-16181610T Aluminum, SAE 10 02-16064212T Aluminum, SAE 12 02-160646

S 04G Steel, 1/2” BSPP 02-16981506G Steel, 3/4” BSPP 02-16981410T Steel, SAE 10 02-16107012T Steel, SAE 12 02-169816

Note: Both the manifold and port plug are required.

87

Coil Model Code*See Section C.

* These model digits will not be stampedon the valve.

9 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

10

44,2 (1.74)

1.26

32,8 (1.29)

19,1 (0.75)

86,3(3.40)

1

2

3

1

2

368,6

(2.70)

64,0(2.52)

Note: EFV2-12 with DIN-43650 connector shown.

Page 32: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-32

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 0 - 35 bar (0 - 500 psi)Cartridge fatigue pressure (infinite life) 35 bar (500 psi)Rated flow 0,2 - 2,8 L/min (0.05 - 0.75 USgpm)Cavity C-10-2Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,43 kg (0.95 lbs)Seal kits 565810 (Buna-N)

889609 (Viton®) Viton is a registered trademark of E.I. DuPont

ERV2-10Proportionally controlledpressure relief valve

Direct acting-low pressue,for pilot control applications

1

2

20

30

600

400

1 2

50 4

6

101 2

1

2

100

15050

40 8

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

1

2

10

20

30

600

200

400

1 2

50

2

4

6

101 2

1

2

100

15050

40 8

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

1

2

10

20

30

00

600

200

400

1 2

0.25 0.50 0.750

50

101 2

0.25 0.50 0.75

1

2

100

15050

40

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

1

2

10

20

30

00

600

200

400

1 2

0.25 0.50 0.7500

50

2

4

6

101 2

0.25 0.50 0.75

1

2

100

15050

40 8

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The ERV2-10 is an electric,proportionally controlled, direct acting, spool type,screw-in relief valve.

Operation

This valve remains closedbetween port 1 and 2 untilthe predetermined pressuresetting has been reached at

port 1, overcoming theelectrical force andunseating the spool toallow flow from port 2.

Pressure override, energized Pressure override, de-energized

Page 33: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-33

B

Model Code ERV2-10

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

6T SAE 6 566151*2G 1/4” BSPP 8767023G 3/8” BSPP 8767036H SAE 6 8767008H SAE 8 876701*Light duty housing.See section J for housings.

5

70

150

210

6 9 volts

0.2 0.3 0.40

VoltsStep response

Response time

Input voltage @ 25C (77F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

bar

seconds

3

6

9

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 47-54 Nm(35-40 ft. lbs)

ERV2 – 10 (V) – ** – ** – *** – * – 00

1 72 3 4 5 86

FunctionERV2 - Proportional reliefvalve

Size 10 - 10 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 0-35 barrange (0-500 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see page section C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR.

7 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

8

Valve is shown with “W” coil.

70

150

210

6 9 volts

0.2 0.3 0.40

VoltsStep response

Response time

Input voltage @ 25C (77F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

bar

seconds

3

6

9

Page 34: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-34

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 3000 psi (210 bar)Cartridge fatigue pressure (infinite life) 3000 psi (210 bar)Rated flow 0,8 L/min (0.20 USgpm)Cavity C-10-2Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,43 kg (0.95 lbs)Seal kits 565810 (Buna-N)

889609 (Viton®) Viton is a registered trademark of E.I. DuPont

ERV3-10Proportionally controlledpressure relief valve

Direct acting-high pressure,for pilot control applications

1

2

20

30

600

400

1 2

50 4

6

101 2

1

2

100

15050

40 8

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

P1 Pressure vs. CurrentERV3-10X-XX-0-00 (with 12VDC coil)

(Top curve: decreasing current, bottom curve: increasing current)

0200400600800

10001200140016001800200022002400260028003000

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1Current (A)

P1 P

ress

ure

(psi

)

ERV3-10X-30-0-00ERV3-10X-20-0-00ERV3-10X-10-0-00

A –B –C –

A

B

C

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The ERV3-10 is an electric,proportionally controlled, direct acting, spool type,screw-in relief valve.

Operation

This valve remains closedbetween port 1 and 2 untilthe predetermined pressuresetting has been reached at

port 1, overcoming theelectrical force andunseating the spool toallow flow from port 2.

Pressure gain curve

Page 35: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-35

B

Model Code ERV3-10

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

A6T SAE 6 566151*A2G 1/4” BSPP 876702A3G 3/8” BSPP 876703A6H SAE 6 876700A8H SAE 8 876701*Light duty housing.See section J for housings.

5

70

150

210

6 9 volts

0.3 0.40

VoltsStep response

Response time

Input voltage @ 25C (77F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

bar

seconds

3

6

9

psi System Pressure

1 1.2 1.4 1.6 1.8 2Time (sec)

0

500

1000

1500

2000

2500

3000

3500

A - CurrentB - P1 Pressure

Port

1 P

ress

ure

(psi

)

PerformanceCharacteristics

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 47-54 Nm(35-40 ft. lbs)

ERV3 – 10 (V) – ** – *** – *** – * – * – 00

1 72 3 4 5 96

FunctionERV3 - Proportional reliefvalve (high pressure)

Size 10 - 10 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 35-210 barrange (500-3000 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR.

7 Coil SeriesBlank - No CoilJ - J Series Coil

Special Features00 - NoneBlank - No Coil

(Only required when valvehas special features, omittedif ”00.“)

9

8

Valve is shown with “W” coil.

8

VoltsStep responsepsibar

Step ResponseERV3-10X-30-0-00, 3500-psi System Pressure

0

0.2

0.4

0.6

0.8

1

1.2

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2Time (sec)

0

500

1000

1500

2000

2500

3000

3500

A - CurrentB - P1 Pressure

Port

1 P

ress

ure

(psi

)

Curr

ent(

A)

AB

Step Response Curve

Page 36: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-36

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 2 - 240 bar (30 - 3500 psi)Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)Rated flow 3,8 - 60,0 L/min (1 - 15 USgpm)Cavity C-10-2Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,44 kg (0.98 lbs)Seal kits 565803 (Buna-N)

565086 (Viton®) Viton is a registered trademark of E.I. DuPont

ERV1-10Proportionally controlledpressure relief valve

1

2

1

2

50

150

200

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

1000

2000

300010 20 30 40 50

2

4

6

50

10010 20 30 40 50

100

1

2

1

2

50

150

200

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

1000

2000

300010 20 30 40 50

2

4

6

00

50

10010 20 30 40 50

100

1

2

1

2

50

150

200

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

Pre

ssu

re D

rop

- p

si

00

1000

2000

300010 20 30 40 50

105

2

4

6

00

50

10010 20 30 40 50

15 5 10 15

100

1

2

1

2

50

150

200

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

Pre

ssu

re D

rop

- p

si

Pre

ssu

re D

rop

- b

ar

00

1000

2000

300010 20 30 40 50

105

2

4

6

00

50

10010 20 30 40 50

15 5 10 15

100

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The ERV1-10 is an electric,proportionally controlled, internally pilot operated, spooltype, screw-in relief valve.

Pressure override, energized Pressure override, de-energized

Operation

This valve remains closedbetween port 1 and 2 untilthe predetermined pressuresetting has been reached at

port 1, overcoming theelectrical force and open-ing the spool to allowflow from port 1 to port 2.

Page 37: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-37

B

ERV1 – 10 (V) – ** – ** – *** – * – 00

1 72 3 4 5 86

Model Code ERV1-10

FunctionERV1 - Proportional reliefvalve

Size 10 - 10 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

6T SAE 6 566151*2G 1/4” BSPP 8767023G 3/8” BSPP 8767036H SAE 6 8767008H SAE 8 876701*Light duty housing. See section J for housings.

5Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 35-210 barrange (500-3000 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications.

6

4

73,0 (2.87)

33,3 (1.31)

0.1 0.2 0.3 0.40

70

140

210

VoltsStep responsepsibar

Response time

Input voltage @ 25°C (77°F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

psi

Pre

ssu

re -

bar

seconds

3

6

9

1000

2000

3000

0

70

140

210

280

1000

2000

3000

0 3 6 9volts

4000

38,9 (1.53)

73,0 (2.87)

33,3 (1.31)

0.1 0.2 0.3 0.40

70

140

210

VoltsStep responsepsibar

Response time

Input voltage @ 25°C (77°F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

psi

Pre

ssu

re -

bar

seconds

3

6

9

1000

2000

3000

0

70

140

210

280

1000

2000

3000

0 3 6 9volts

4000

38,9 (1.53)

73,0(2.87)

33,3(1.31)

Ø 15,80 (0.622)

0.875"-14 Thd.

25,4 (1.00) Hex

1

19,0 (0.75) Hex

2

0.3 0.40

VoltsStep response

Response time

Input voltage @ 25C (77F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

bar

seconds

3

6

9

70

140

210

280

6 9volts

Ø 38,9(1.53)

29,6(1.16)

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 47-54 Nm (35-40 ft. lbs)

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Valve is shown with “W” coil.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

8

Page 38: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-38

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 3,5 - 210 bar (50 - 3000 psi)Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)Rated flow 7,6 - 132,0 L/min (2 - 35 USgpm)Cavity C-16-2Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,44 kg (0.98 lbs)Seal kits 565810 (Buna-N)

889609 (Viton®) Viton is a registered trademark of E.I. DuPont

ERV1-16Proportionally controlledpressure relief valve

1

2

70

140

210

00

1000

2000

300040 80 120 160

10 20 30 40 50

40 80 120 160

2

4

7

0010 20 30 40 50

60

100

1

2

30

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar1

2

70

140

210

00

1000

2000

300040 80 120 160

10 20 30 40 50

40 80 120 160

2

4

7

0010 20 30 40 50

60

100

1

2

30

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

1

2

70

140

210

00

1000

2000

300040 80 120 160

10 20 30 40 50

Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

1

2

70

140

210

00

1000

2000

300040 80 120 160

10 20 30 40 50

40 80 120 160

2

4

7

0010 20 30 40 50

60

100

1

2

30

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The ERV1-16 is an electric,proportionally controlled, internally pilot operated, spooltype, screw-in relief valve.

Pressure override,energized

Pressure override, de-energized

Operation

This valve remains closedbetween port 1 and 2 untilthe predetermined pressuresetting has been reached at

port 1, overcoming theelectrical force andunseating the spool toallow flow from port 2.

Page 39: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-39

B

Model Code ERV1-16

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

12T SAE 12 566149*4G 1/2” BSPP 8767166G 3/4” BSPP 87671810H SAE 10 87671712H SAE 12 566113*Light duty housing. See section J for housings.

5

0.1 0.2 0.3 0.40

70

140

210

VoltsStep responsepsibar

Response time

Input voltage @ 25°C (77°F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

psi

Pre

ssu

re

Pre

ssu

re -

bar

seconds

3

6

9

1000

2000

3000

0

70

140

210

280

1000

2000

3000

0 3 6 9volts

3600

38,9 (1.53)

0.1 0.2 0.3 0.40

70

140

210

VoltsStep responsepsibar

Response time

Input voltage @ 25°C (77°F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

psi

Pre

ssu

re

Pre

ssu

re -

bar

seconds

3

6

9

1000

2000

3000

0

70

140

210

280

1000

2000

3000

0 3 6 9volts

3600

38,9 (1.53)

79,0(3.1)

44,4(1.75)

Ø 28,55 (1.124)

1.312"-12 Thd.

38,1 (1.50) Hex

1

19,0 (0.75) Hex Torque to 5-8 Nm

2

0.3 0.40

VoltsStep response

Response time

Input voltage @ 25C (77F)

Pressure gain

Inp

ut

volt

age

Pre

ssu

re -

bar

seconds

3

6

9

70

140

210

280

6 9volts

Ø 38,9(1.53)

29,6(1.16)

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 108-122 Nm(80-90 ft. lbs)

ERV1 – 16 (V) – ** – *** – *** – * – 00

1 72 3 4 5 86

FunctionERV1 - Proportional reliefvalve

Size 16 - 16 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 35-210 barrange (500-3000 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

8

Valve is shown with “W” coil.

Page 40: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-40

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Maximum inlet pressure 35 bar (500 psi)Cartridge fatigue pressure (infinite life) 35 bar (500 psi)Reduced pressure range 0 - 22 bar (0 - 320 psi)Maximum operating flow 7,6 L/min (2 USgpm)Cavity C-8-3Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Recommended PWM frequency 150 HzHysteresis @ 150 Hz PWM 5%Weight including coil 0,29 kg (0.64 lbs)Seal kits 02-179451 (Buna-N)

02-179452 (Viton®) Viton is a registered trademark of E.I. DuPont

EPRV2-8Proportional pressurereducing-relieving valve

7

14

21

28

35

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Pre

ssu

re d

rop

- p

si

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re d

rop

- b

ar

3 (T)

2 (P)

1 (RP)

1 (RP)

3(T)2(P)

8

100

200

300

400

84 4500

Relieving mode Reducing mode0100

75

50

25

0

7

6

4

2

0

2 4 6 8

A

B

7

14

21

28

35

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re d

rop

- p

si

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re d

rop

- b

ar

3 (T)

2 (P)

1 (RP)

1 (RP)

3(T)2(P)

8

100

200

300

400

2 1 0 21

84 4500

Relieving mode Reducing mode0100

75

50

25

0

7

6

4

2

0

2 4 6 8

0.5 1.0 1.5 2.0

A

B

7

14

21

28

35

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re d

rop

- p

si

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re d

rop

- b

ar

3 (T)

2 (P)

1 (RP)

1 (RP)

3(T)2(P)

8

100

200

300

400

2 1 0 21

84 4500

Relieving mode Reducing mode0100

A - Port 1 to port 3 B - Port 2 to port 1

75

50

25

0

7

6

4

2

0

2 4 6 8

0.5 1.0 1.5 2.0

A

B7

14

21

28

35

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

Pre

ssu

re d

rop

- p

si

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re d

rop

- b

ar

3 (T)

2 (P)

1 (RP)

1 (RP)

3(T)2(P)

8

100

200

300

400

2 1 0 21

84 4500

Relieving mode Reducing mode0100

A - Port 1 to port 3 B - Port 2 to port 1

75

50

25

0

7

6

4

2

0

2 4 6 8

0.5 1.0 1.5 2.0

A

B

Functional Symbol

Sectional View

Pressure Characteristics

Description

The EPRV2-8 is a proportion-al, pressure reducing-reliev-ing, sliding spool, electricallycontrolled, screw-in cartridgetype valve.

Operation

In the de-energized position,pressure inlet port 2 isclosed and reduced pres-sure port 1 is open to returnport 3. As electrical current

is increased, port 2 opensto port 1 and port 3 closes,proportionally increasingpressure at port 1. If thepressure at port 1 exceeds

the setting of the valve,the spool will shift furtherand relieve to port 3.

Pressure drops vs flow Pressure drops vs flow

Page 41: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-41

B

EPRV2 – 8 (V) – (A) – ** – *** – * * – 00

1 7 82 3 4 5 96

Model Code EPRV2-8

FunctionEPRV2 - Proportionalreducing/relieving valve

Size 8 - 8 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

4T SAE 4 02-1607416T SAE 6 02-1607422G 1/4” BSPP 02-1607393G 3/8” BSPP 02-160740See section J for housings.

5Valve housing material Omit for cartridge onlyA - Aluminum

Voltage rating00 - No coil12D - 12VDC24D - 24VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard S series, coils, see section C for part numbers and specifications.

6

4

Amperageincreasing

Amperagedecreasing

Step responsepsibar

Time - sec

Red

uce

d p

ress

ure

Red

uce

d p

ress

ure

- p

si

Red

uce

d

pre

ssu

re -

bar

Am

per

age

200

400

600

0

42

28

14

0.1 0.2 0.3 0.40

1.2

0.8

0.4

.1 .2 .3 .4

.1 .3 .5 .7 .9 (12 VDC)

(24 VDC)

400

300

200

100

28

21

14

7

Regulated pressure vs amperage

(12 VDC)

Amperageincreasing

Amperagedecreasing

Step responsepsibar

Time - sec

Red

uce

d p

ress

ure

Red

uce

d p

ress

ure

- p

si

Red

uce

d

pre

ssu

re -

bar

Am

per

age

200

400

600

0

42

28

14

0.1 0.2 0.3 0.40

1.2

0.8

0.4

.1 .2 .3 .4

.1 .3 .5 .7 .9 (12 VDC)

(24 VDC)

400

300

200

100

28

21

14

7

Regulated pressure vs amperage

(12 VDC)

Amperageincreasing

Step response

Red

uce

d

pre

ssu

re -

bar

Am

per

age

0.3 0.40

1.2

0.8

0.4

.4

.7 .9 (12 VDC)

(24 VDC)

28

21

14

7

Regulated pressure vs amperage

1

(12 VDC)

PerformanceCharacteristics

Dimensionsmm (inch)

Torque cartridge in aluminum orsteel housing 34-41 Nm (25-30 ft. lbs)

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 CoilS - S Series Coils

Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

9

8

Valve is shown with “N” coil.

Page 42: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-42

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 3,5 - 35 bar (50 - 500 psi)Cartridge fatigue pressure (infinite life) 35 bar (500 psi)Rated flow 0 - 7,6 L/min (0 - 2.0 USgpm)Cavity C-10-3Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,44 kg (0.98 lbs)Seal kits 565804 (Buna-N)

889599 (Viton®) Viton is a registered trademark of E.I. DuPont

EPRV1-10Proportional pressurereducing-relieving valve

7

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar28

42600

400

47

1

345

15

0 04 747 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)7

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

14

28

42

200

600

400

47

1

345

15

0 04 747 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

7

0

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

14

28

42

0

200

600

400

47

00

0

45

15

0 04

12 21 12 1 2

47 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°

Flow - USgpm (135 SUS oil @ 120Flow - USgpm (135 SUS oil @ 120°F)

7

0

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

14

28

42

0

200

600

400

47

0

1

3

000

45

15

0 04

12 21 12 1 2

747 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

Flow - USgpm (135 SUS oil @ 120°F)Flow - USgpm (135 SUS oil @ 120°F)

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The EPRV1-10 is an electric,proportionally controlled,internally pilot operated, spooltype, screw-in relief valve.

Pressure override, energized Pressure override, de-energized

Operation

This valve remains openfrom port 2 to port 1 (port3 must be vented). Oncethe predetermined pres-sure is reached at port 1,

the spool shifts torestrict the inlet flow atport 2, which regulatesthe pressure at port 1. If the pressure at port 1

exceeds the setting ofthe valve, the spool willshift farther and relieveto port 3.

Page 43: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-43

B

Model Code EPRV1-10

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

3B 3/8” BSPP 02-173358*6T SAE 6 566162*2G 1/4” BSPP 8767023G 3/8” BSPP 8767146H SAE 6 8767048H SAE 8 876711*Light duty housing. See section J for housings.

5

0.1 0.2 0.3 0.40

200

400

volts

seconds

Step response

Response time

Input voltage @ 25°C (77°F)

Pressure gain

psibar

3

6

9600

0

42

28

14

Red

uce

d p

ress

ure

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Inp

ut

volt

age

17

34

250

500

0 3 6 9 volts

38,9 (1.53)

0.1 0.2 0.3 0.40

200

400

volts

seconds

Step response

Response time

Input voltage @ 25°C (77°F)

Pressure gain

psibar

3

6

9600

0

42

28

14

Red

uce

d p

ress

ure

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Inp

ut

volt

age

17

34

250

500

0 3 6 9 volts

38,9 (1.53)

0.3 0.4

volts

seconds

Step response

Response time

Input voltage @ 25C (77F)

Pressure gain

3

6

9

Pre

ssu

re -

bar

Inp

ut

volt

age

1

17

34

6 9 volts

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 47-54 Nm (35-40 ft. lbs)

EPRV1 – 10 (V) – ** – ** – *** * – 00

1 72 3 4 5 86

FunctionEPRV1 - Proportionalreducing/relieving valve

Size 10 - 10 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 14-35 barrange (200-500 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC36D - 36VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

8

Valve is shown with “W” coil.

Page 44: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-44

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 3,5 - 207 bar (50 - 3000 psi)Maximum Inlet Pressure 240 bar (3500 psi)Cartridge fatigue pressure (infinite life) 207 bar (3000 psi)Rated flow 30 L/min (8 USgpm)Cavity C-10-3Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,44 kg (0.98 lbs)Seal kits 565804 (Buna-N)

889599 (Viton®) Viton is a registered trademark of E.I. DuPont

EPRV3-10Proportional pressurereducing-relieving valve

7

0

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

14

28

42

0

200

600

400

47

0

1

3

000

45

15

0 04

12 21 12 1 2

747 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

Flow - USgpm (135 SUS oil @ 120°F)Flow - USgpm (135 SUS oil @ 120°F)

Reducing ModeEPRV3-10X-XX-0-00

0

500

1000

1500

2000

2500

3000

0 1 2 3 4 5 6 7 8Flow (gpm)

A – EPRV3-10X-30-0-00B – EPRV3-10X-10-0-00C – EPRV3-10X-20-0-00

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The EPRV3-10 is an electric,proportionally controlled,internally pilot operated, spooltype, screw-in relief valve.

Pressure override, energized

Pressure override, de-energized

Operation

This valve remains openfrom port 2 to port 1 (port3 must be vented). Oncethe predetermined pres-sure is reached at port 1,

the spool shifts torestrict the inlet flow atport 2, which regulatesthe pressure at port 1. If the pressure at port 1

exceeds the setting ofthe valve, the spool willshift farther and relieveto port 3.

3200

2800

2400

2000

1600

1200

800

400

00 1 2 3 4 5 6 7 8

Flow (gpm)

P1 P

ress

ure

A – EPRV3-10X-10-0-00B – EPRV3-10X-20-0-00C – EPRV3-10X-30-0-00

A

B

C

Page 45: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-45

B

Model Code EPRV3-10

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

A3B 3/8” BSPP 02-173358*A6T SAE 6 566162*A2G 1/4” BSPP 876702A3G 3/8” BSPP 876714A6H SAE 6 876704A8H SAE 8 876711*Light duty housing. See section J for housings.

5

0200400600800

100012001400160018002000220024002600280030003200

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Redu

ced

Pres

sure

(psi

)

0200400600800

1000120014001600180020002200240026002800300032003400

0 0.1 0.2 0.3 0.4

Redu

ced

Pres

sure

(psi

)

0

0.2

0.4

0.6

0.8

1

Inpu

t Cur

rent

(A)

Current (A)

Time (seconds) A – EPRV3-10X-10-0-00B – EPRV3-10X-20-0-00C – EPRV3-10X-30-0-00

A – EPRV3-10X-10-0-00B – EPRV3-10X-20-0-00C – EPRV3-10X-30-0-00

A

B

C

A

B

C

0.4

volts

seconds

Step response

Response time

Input voltage @ 25C (77F)

3

6

9

Pre

ssu

re -

bar

Inp

ut

volt

age

1

17

34

9 volts

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 47-54 Nm (35-40 ft. lbs)

EPRV3 – 10 (V) – ** – ** – *** * – 00

1 72 3 4 5 86

FunctionEPRV3 - Proportionalreducing/relieving valve

Size 10 - 10 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 35-207 barrange (500-3000 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil012D - 12VDC024D - 24VDC012B - 12VDC/w diode*024B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, see section C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 Coil SeriesBlank - No coilJ - J series coil

Coil Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

9

8

Valve is shown with “W” coil.

0200400600800

100012001400160018002000220024002600280030003200

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Redu

ced

Pres

sure

(psi

)

0200400600800

1000120014001600180020002200240026002800300032003400

0 0.1 0.2 0.3 0.4

Redu

ced

Pres

sure

(psi

)

0

0.2

0.4

0.6

0.8

1

Inpu

t Cur

rent

(A)

Current (A)

Time (seconds) A – EPRV3-10X-10-0-00B – EPRV3-10X-20-0-00C – EPRV3-10X-30-0-00

A – EPRV3-10X-10-0-00B – EPRV3-10X-20-0-00C – EPRV3-10X-30-0-00

A

B

C

A

B

C

Step Response Curve

Pressure vs. Current

Page 46: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-46

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)Typical application pressure (all ports) 3,5 - 35 bar (0 - 500 psi)Cartridge fatigue pressure (infinite life) 35 bar (500 psi)Rated flow 0 - 38,0 L/min (0 - 10 USgpm)Cavity C-16-3Standard housing materials AluminumTemperature range -40° to 120°C (-40° to 248°F)Fluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Weight cartridge and coil 0,9 kg (2.00 lbs)Seal kits 565811 (Buna-N)

889599 (Viton®) Viton is a registered trademark of E.I. DuPont

EPRV1-16Proportional pressurereducing-relieving valve

7

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

psi

Pre

ssu

re -

bar

14

28

42

200

600

400

47

1

345

15

0 04 747 4

1 (RP)

2 (P)3 (T)

3

2

1

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

14

28

42

00

200

60038 19

10 5 0

2

3

00

50

25

5 10

0 3819 38 19 0 3819

1 (RP)

2 (P)3 (T)

3

2

1

400

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

Pre

ssu

re -

psi

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

bar

14

28

42

00

200

60038 19

10 5 0

2

3

0010 5 0

50

25

5 10

0 3819

105

38 19 0 3819

1 (RP)

2 (P)3 (T)

3

2

1

400

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

Flow - USgpm (135 SUS oil @ 120°F) Flow - USgpm (135 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

bar

14

28

42

00

200

60038 19

10 5 0

2

3

0010 5 0

50

25

5 10

0 3819

105

38 19 0 3819

1 (RP)

2 (P)3 (T)

3

2

1

400

Flow - L/min (28,0 cSt oil @ 49°C) Flow - L/min (28,0 cSt oil @ 49°C)

Flow - USgpm (135 SUS oil @ 120°F) Flow - USgpm (135 SUS oil @ 120°F)

Pre

ssu

re -

psi

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Pre

ssu

re -

bar

Functional Symbol

Sectional View

Pressure Override Characteristics

Description

The EPRV1-16 is an electric,proportionally controlled,internally pilot operated, spooltype, screw-in relief valve.

Pressure override, energized Pressure override, de-energized

Operation

This valve remains openfrom port 2 to port 1 (port 3must be vented). Once thepredetermined pressure is

reached at port 1, the spoolshifts to restrict the inletflow at port 2, which regu-lates the pressure at port 1.

If the pressure at port 1exceeds the setting of thevalve, the spool will shift far-ther and relieve to port 3.

Page 47: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-47

B

Model Code EPRV1-16

Port size0 - Cartridge only

CODE PORT SIZE HOUSING NUMBER

6B 3/4” BSPP 02-175465*12T SAE 12 566162*6G 3/4” BSPP 87672210H SAE 10 87672112H SAE 12 876723*Light duty housing. See section J for housings.

5

0,1 0,2 0,3 0,40

38,9 (1.53)

(0.77)

200

400

volts

seconds

Step responsebar psi

Response time

Input voltage @ 25°C (77°F)

Pressure gain

3

6

9600

0

42

28

14

Red

uce

d p

ress

ure

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Inp

ut

volt

age

17

34

250

500

0 3 6 9 volts

0,1 0,2 0,3 0,40

38,9 (1.53)

19,4 (0.77)

200

400

volts

seconds

Step responsebar psi

Response time

Input voltage @ 25°C (77°F)

Pressure gain

3

6

9600

0

42

28

14

Red

uce

d p

ress

ure

Pre

ssu

re -

psi

Pre

ssu

re -

bar

Inp

ut

volt

age

17

34

250

500

0 3 6 9 volts

1

0,3 0,40

volts

seconds

Step response

Response time

Input voltage @ 25C (77F)

Pressure gain

3

6

9

Pre

ssu

re -

bar

Inp

ut

volt

age

17

34

6 9 volts

PerformanceCharacteristics

Cartridges only

Zero outlet pressure

Dimensionsmm (inch)

Torque cartridge in aluminumhousing 108-122 Nm(80-90 ft. lbs)

EPRV1 – 16 (V) – ** – *** – *** – * – 00

1 72 3 4 5 86

FunctionEPRV1 - Proportionalreducing/relieving valve

Size 16 - 16 Size

SealsBlank - Buna-N V - Viton®

3

2

1 Maximum pressure (factory set)Customer to specify settingsin increments of 7 bar (100psi) and coded in hundredsof psi within the 14-35 barrange (200-500 psi) range.

Example: 5 - 35,0 (500 psi)

Voltage rating00 - No coil12D - 12VDC24D - 24VDC36D - 36VDC12B - 12VDC/w diode*24B - 24VDC/w diode**Optional arc suppressing diode.

Note: This valve uses the standard J series coils, seesection C for coil part numbers and specifications.

6

4

WARNING

Maintain 5-8 Nm(4-6 ft. lbs) maxi-

mum torque on valve tubenut. Over tightening maycause valve failure.

Connector TypesBlank - No coilG - DIN 43650Q - Spade terminalsW - LeadwireN - DeutchY - Amp JR

7 Special Features00 - None

(Only required when valvehas special features, omittedif ”00.“)

8

Valve is shown with “W” coil.

Page 48: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-48

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 10 cSt (48 SUS) and 49°C (120°F)Maximum inlet pressure 100 bar (1450 psi)Cartridge fatigue pressure (infinite life) 100 bar (1450 psi)Regulation 0 - 10 L/min (0 - 2 USgpm)

* at 10 bar (145 psi) pressure drop

Maximum operating flow 10 L/min (2.6 USgpm)Cavity 38118_0Leakage (P, A Þ T) < 10 cc/minTemperature range -30° to 125°CFluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Hysteresis < 8%Weight including coil 220g (0.1 lbs)Coil Resistance 2.5 ohmMax Control Current 2 AmpElectrical Connection Metripac 150Part Number 5986803-001

758 SeriesProportionalFlow RegulatorValve (Slip-inType)Proportional flow controlvalve

Functional Symbol

Sectional View

Description

The 758 Series ProportionalFlow Regulator Valve is aproportional, flow controlvalve, designed for pilot con-trol, applications.

Operation

In the de-energized position,port A is open to port T. Aselectrical current isincreased, the opening

between port A and port Tis reduced and port P isopened to port A.

Regulation Curve

Regulation

I I

5986803-001

Page 49: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-49

B

758 SeriesProportionalFlow RegulatorValve

Dimensions

mm

Cavity and InstallationDetails

mm

Cavity ref: 38118-0

Page 50: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006B-50

RATINGS AND SPECIFICATIONS

Performance data is typical with fluid at 10 cSt (48 SUS) and 49°C (120°F)Maximum inlet pressure 100 bar (1450 psi)Cartridge fatigue pressure (infinite life) 100 bar (1450 psi)Reduced pressure range 0 - 60 bar (0 - 870 psi)Maximum operating flow 10 L/min (2.6 USgpm)Cavity 38117_0 SpecialLeakage (P, A Þ T) < 10 cc/minTemperature range -30° to 125°CFluids All general purpose hydraulic fluids such as:

MIL-H-5606, SAE 10, SAE 20, etc.Filtration Cleanliness code 18/16/13Hysteresis < 4%Weight including coil 220g (0.1 lbs)Coil Resistance 2.5 ohmMax Control Current 2.4 AmpResponse Time 0-60 bar < 20 ms

60-0 bar < 20 msFrequency response from 0.3 to 35 Hz Presure gain ± 3 dB

Frequency phase < -90°CElectrical Connection Metripac 150Part Number 4997994-001

758 SeriesProportionalPressure ControlValve (Slip-inType)Proportional pressurereducing valve

Regulation

Functional Symbol

Sectional View

Pressure Characteristics

Description

The 758 Series ProportionalPressure Control Valve is aproportional, pressure reduc-ing-relieving valve designedfor pilot control applications.

Operation

In the de-energized position,pressure inlet port P isclosed and reduced pres-sure port A is open to returnport T. As electrical current

is increased, port A opensto port P and port T closes,proportionally increasingpressure at port A.

Regulation Curve

4997994-001

Page 51: Proportional Valves · 2020. 4. 16. · Proportional valve solenoid coils and electronic valve drivers are cov-ered in section C of this Catalog. dling flows from 3,8-60,0 L/min (1-15

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E3 January 2006 B-51

B

758 SeriesProportionalPressure ControlValve

Dimensions

mm

Cavity and InstallationDetails

mm

Cavity ref: 38117-0