proportional cartridge valves - homepage ......max power consumption 11 watt (20 c) coil termination...

63
Manufacturers of hydraulic cartridge valves and electro-hydraulic systems PROPORTIONAL CARTRIDGE VALVES

Upload: others

Post on 10-Jan-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Manufacturers of hydraulic cartridge valves

and electro-hydraulic systems

PROPORTIONAL CARTRIDGE VALVES

Page 2: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD1

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

PROPORTIONAL PRESSURE CONTROLS

PROPORTIONAL PRESSURE REDUCING / RELIEVING VALVES ...................................................................... PD3

PROPORTIONAL PRESSURE RELIEF VALVES .................................................................................................. PD19

PROPORTIONAL FLOW CONTROLS

2 WAY NORMALLY CLOSED PROPORTIONAL FLOW REGULATOR VALVES ................................................... PD25

2 WAY NORMALLY OPEN PROPORTIONAL FLOW REGULATOR VALVES ....................................................... PD37

2 WAY NOR. CLOSED PRESSURE COMPENSATED PROP. FLOW REGULATOR VALVES .............................. PD41

3 WAY NOR. CLOSED PRESSURE COMPENSATED PROP. FLOW REGULATOR VALVES .............................. PD47

4W/3P PROPORTIONAL DIRECTIONAL CONTROL VALVES ............................................................................. PD53

Section / Description page

PROPORTIONAL CONTROLS

Page 3: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD2

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 4: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD3

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

DIRECT ACTING GPM PSI LPM BAR CAVITY MODEL PAGE

1 700 4 50 slip-in IP-DAR-250-L PD4

1 700 4 50 slip-in IP-DAR-43C-L PD6

1 5000 4 345 slip-in IP-DAR-43C-H PD6

(2)

(1) (3)

7.5 700 30 50 slip-in IP-RDS-222-L PD8

PILOT OPERATED GPM PSI LPM BAR CAVITY MODEL PAGE

15 3000 57 207 7/8-14 EF-PRP PD10

7.9 700 30 50 slip-in IP-PRZ-59-AM12 PD12

8 450 30 31 7/8-14 EG-PRZ PD14

30 450 114 31 1 1/16-12 ES-PRZ PD16

PROPORTIONAL PRESSURE REDUCING / RELIEVING VALVES

Page 5: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD4

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 21 / 2019

IP-DAR-250 DIRECT ACTING PROPORTIONAL, PRESSURE REDUCING/RELIEVING, SLIP-IN TYPE

DESCRIPTIONSpecial cavity, slip-in style flange retained, direct acting proportional, pressure reducing/relieving valve.

OPERATIONThe IP-DAR-250 generates a variable pressure in response to a PWM (Pulse Width Modulated) current signal. With no current applied to the proportional solenoid, the inlet port 2 (P) is blocked and the regulated port 3 (C) is vented to port 1 (T). As current is increased, fluid pressure is proportionally controlled at the regulated port 3 (C). On attainment of proportionally determined pressure at 3 (C), the cartridge shifts to block flow at 2 (P), thereby regulating pressure at 3 (C). In this mode, the valve also will relieve 3 (C) to 1 (T) at a variable value over the set reducing pressure.

FEATURES • Slip-in style.• Efficient wet-armature construction.• Integral waterproof coil.• Continuous duty rated solenoid.

Flanged retained product. The coil is an integral part of the valve and is not serviceable. Eventual tank pressure exceeding 0 bar, has to be added to reduced pressure value.

Nominal Flow 1 GPM (4 LPM) @ 8 bar Delta PMax Inlet Pressure “L” version 700 PSI (50 bar)Controlled Pressure Range 0÷25 bar / 0÷30 bar / 0÷35 bar (see graph)Reduced Pressure Tolerance ±5%Max Back-Pressure at T Port 30 barInternal Leakage 15 ml/min @ 500 PSI (35 bar) inletViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/15/13Media Operating Temp. Range -30°C / +100°CWeight .43 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity T250Cavity Tool Kit K-T250Flange Mounting Screws and Torque M4x10 / 3ft-lbs (4 Nm)

VALVE SPECIFICATIONS

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 200÷1500 (12 V coil) 100÷750 (24 V coil)PWM or Super-Imposed Dither Freq. 100-200 HzCoil Resistance (12 VDC) 4.8 Ohm ±5% at 68°F (20°C) (24 VDC) 20 Ohm ±5% at 68°F (20°C)Max Power Consumption 11 Watt (20°C)Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)Color Connectors BlackProtection Degree (according to IEC 529) IP 69K (DT) IP 67 (AJ)

COIL SPECIFICATIONS

HYDRAULIC SYMBOL

PERFORMANCE

B

A

1000600 800 1200

30

20

10

2000 400

40

1400 1600

30 bar

25 bar

35 b

ar

500300 400 600100 200 700 800

TECNORDSERVOCOMANDI E REGOLAZIONE

Pressure Vs. Current CharacteristicOil viscosit 46 cSt @ 45°C

B

A

1000600 800 1200

30

20

10

2000 400

40

1400 1600

30 bar

25 bar

35 b

ar

500300 400 600100 200 700 800

TECNORDSERVOCOMANDI E REGOLAZIONE

(C)

(Bar)

l(mA)l(mA)

Page 6: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD5

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

1 /

2019

IP-DAR-250 – – – –

COILTERMINATION

VOLTAGE INLETPRESSURE

MAXREGULATEDPRESSURE

OPTIONS BODIES

AJ - AMP Jr. Timer 12 VDC L - up to 700 PSI (50 bar)

20 bar AH - HNBR seals and 300 μm

(50 mesh) screen on port 2

Blank - Without body

DT - Deutsch DT04

24 VDC 25 bar N - 1/4” BSP Ports

32 bar

DIMENSIONS

ORDERING INFORMATION

DT version AJ version

B

A

1000600 800 1200

30

20

10

2000 400

40

1400 1600

30 bar

25 bar

35 b

ar

500300 400 600100 200 700 800

TECNORDSERVOCOMANDI E REGOLAZIONE

B

A

1000600 800 1200

30

20

10

2000 400

40

1400 1600

30 bar

25 bar

35 b

ar

500300 400 600100 200 700 800

TECNORDSERVOCOMANDI E REGOLAZIONE

Page 7: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD6

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

IP-DAR-43C DIRECT ACTING PROPORTIONAL, PRESSURE REDUCING/RELIEVING, SLIP-IN TYPE

DESCRIPTIONSpecial cavity, slip-in style flange retained, direct acting proportional, pressure reducing/relieving valve.

OPERATIONThe IP-DAR-43C-AJ12 generates a variable pressure in response to a PWM (Pulse Width Modulated) current signal. With no current applied to the proportional solenoid, the inlet port 2 (P) is blocked and the regulated port 3 (U) is vented to port 1 (T). As current is increased, fluid pressure is proportionally controlled at the regulated port 3 (U). On attainment of proportionally determined pressure at 3 (U), the cartridge shifts to block flow at 2 (P), thereby regulating pressure at 3 (U). In this mode, the valve also will relieve 3 (U) to 1 (T) at a variable value over the set reducing pressure.

FEATURES • Slip-in style.• Efficient wet-armature construction.• Integral waterproof coil.• Continuous duty rated solenoid.

Flanged retained product. The coil is an integral part of the valve and is not serviceable. Eventual tank pressure exceeding 0 bar, has to be added to reduced pressure value.

Nominal Flow 1 GPM (4 LPM) @ 8 bar Delta PMax Inlet Pressure “H” version 5000 PSI (345 bar)Max Inlet Pressure “L” version 700 PSI (50 bar)Controlled Pressure Range 0÷25 bar / 0÷30 bar (see graph)Reduced Pressure Tolerance ±5%Max Back-Pressure at T Port 20 barInternal Leakage 15 ml/min @ 500 PSI (35 bar) inlet 35 ml/min @ 5000 PSI (350 bar) inletViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/15/13 (ISO 4406)Media Operating Temp. Range -25°C / +90°CWeight .54 lbs (.25 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity T043Cavity Tool Kit K-T043Flange Mounting Screws and Torque M4x10 / torque 3ft-lbs (4 Nm)

VALVE SPECIFICATIONS

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 200÷1500 (12V coil) 100÷750 (24V coil)PWM or Super-Imposed Dither Freq. 100-200 HzCoil Resistance (12 VDC) 5.4 Ohm ±5% at 68°F (20°C)Coil Resistance (24 VDC) 22 Ohm ±5% at 68°F (20°C)Max Power Consumption 12 Watt (20°C)Protection Degree IP 67 according to IEC 529Coil Termination Deutsch-Integral DT04-2P AMP Jr. Timer 84-9419Color Connectors Black

COIL SPECIFICATIONS

HYDRAULIC SYMBOL

PERFORMANCE

1 (T)

2 (P)

3 (U)

Reduced pressure (bar) vs. Current (mA)12 V and 24 V Coil

1 (T)

2 (P)

3 (U)

P (bar)

l (mA) @ 12V l (mA) @ 24V

Page 8: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD7

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

IP-DAR-43C – – – – –

COILTERMINATION

VOLTAGE INLETPRESSURE

MAXREGULATEDPRESSURE

OPTIONS

AJ - AMP Jr. Timer 1-12 VDC L - up to 700 PSI (50 bar)

1-25 bar 00 - HNBRstandard

DT - Deutsch DT04

2-24 VDC H - up to 5000 PSI (345 bar)

2-30 bar A0 - with filter

DIMENSIONS

ORDERING INFORMATION

DT version AJ version

Page 9: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD8

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

IP-RDS-222 DIRECT ACTING PROPORTIONAL, PRESSURE REDUCING/RELIEVING, SLIP-IN TYPE

DESCRIPTIONSpecial cavity, slip-in style flange retained, "step bore" direct acting proportional, pressure reducing/relieving valve.

OPERATIONThe IP-RDS-222 generates a variable pressure in response to a PWM (Pulse Width Modulated) current signal. With no current applied to the proportional solenoid, the inlet port 1 (P) is blocked and the regulated port 2 (C) is vented to port 3 (T). As current is increased, fluid pressure is proportionally controlled at the regulated port 2 (C). On attainment of proportionally determined pressure at 2 (C), the cartridge shifts to block flow at 1 (P), thereby regulating pressure at 2 (C). In this mode, the valve also will relieve 2 (C) to 3 (T) at a variable value over the set reducing pressure.

FEATURES • Slip-in style.• Efficient wet-armature construction.• Integral waterproof coil.• Continuous duty rated solenoid.

Flanged retained product. The coil is an integral part of the valve and is not serviceable. Eventual tank pressure exceeding 0 bar, has to be added to reduced pressure value.

Nominal Flow 7.5 GPM (30 LPM) @ 6 bar Delta PMax Inlet Pressure “L” version 700 PSI (50 bar)Controlled Pressure Range 0÷23 bar / 0÷30 bar / 0÷35 bar (see graph)Reduced Pressure Tolerance ±5%Max Back-Pressure at T Port 25 barInternal Leakage 15 ml/min @ 500 PSI (35 bar) inletViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/15/13Media Operating Temp. Range -30°C / +100°CWeight .58 lbs (.27 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity T222Cavity Tool Kit K-T222Flange Mounting Screws and Torque M4x10 / 3ft-lbs (4 Nm)

VALVE SPECIFICATIONS

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 200÷1500 (12 V coil) 100÷750 (24 V coil)PWM or Super-Imposed Dither Freq. 100-200 HzCoil Resistance (12 VDC) 5.4 Ohm ±5% at 68°F (20°C) (24 VDC) 22 Ohm ±5% at 68°F (20°C)Max Power Consumption 12 Watt (20°C)Coil Termination Deutsch-Integral DT04-2P (DT & DH) AMP Jr. Timer 84-9419 (AJ)Color Connectors BlackProtection Degree (according to IEC 529) IP 69K (DT & DH) IP 67 (AJ)

COIL SPECIFICATIONS

HYDRAULIC SYMBOL

PERFORMANCE

B

1.6

A

TECNORDSERVOCOMANDI E REGOLAZIONE

36

30

24

18

12

6

0 200 400 600 800 1000 1200

8

6

4

2

0 5 10 15 20 25 30

23 ba

r

30 ba

r

35 ba

r

B

1.6

A

TECNORDSERVOCOMANDI E REGOLAZIONE

36

30

24

18

12

6

0 200 400 600 800 1000 1200

8

6

4

2

0 5 10 15 20 25 30

23 ba

r

30 ba

r

35 ba

r

B

1.6

A

TECNORDSERVOCOMANDI E REGOLAZIONE

36

30

24

18

12

6

0 200 400 600 800 1000 1200

8

6

4

2

0 5 10 15 20 25 30

23 ba

r

30 ba

r

35 ba

r

Pressure Vs. Current CharacteristicOil viscosit 46 cSt @ 45°C and PWM 100 Hz

Pressure DropOil viscosit 46 cSt @ 45°C

(2)

(1) (3)

Page 10: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD9

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

IP-RDS-222 – – – –

COILTERMINATION

VOLTAGE INLETPRESSURE

MAXREGULATEDPRESSURE

OPTIONS BODIES

AJ - AMP Jr. Timer 12 VDC L - up to 700 PSI (50 bar)

23 bar A0 - NBR seals and 300 μm

(50 mesh) screen on port 2

Blank - Without body

DT - Deutsch DT04

24 VDC 30 bar N - 3/8” BSP Ports

DH - Deutsch DT04 Horizontal

35 bar

DIMENSIONS

ORDERING INFORMATION

DT version AJ version DH version

B

1.6

A

TECNORDSERVOCOMANDI E REGOLAZIONE

36

30

24

18

12

6

0 200 400 600 800 1000 1200

8

6

4

2

0 5 10 15 20 25 30

23 ba

r

30 ba

r

35 ba

r

B

1.6

A

TECNORDSERVOCOMANDI E REGOLAZIONE

36

30

24

18

12

6

0 200 400 600 800 1000 1200

8

6

4

2

0 5 10 15 20 25 30

23 ba

r

30 ba

r

35 ba

r

Page 11: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD10

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EF-PRP 3 WAY 2 POSITION, PILOT OPERATED, PRESSURE REDUCING, RELIEVING VALVE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, pilot operated, 3 way 2 position, proportional pressure reducing/relieving valve.

OPERATIONWhen de-energized and with a passive load at port (3), the EF-PRP passes sufficient flow from port (2) to port (3) to regulate a minimum pressure of approximately 3-10 bar (45-145 PSI). With a supplied flow from an external source into port (3) the valve will regulate the minimum pressure as shown on curve below by bypassing flow to port (1). When energized, the actuator creates a force proportional to the applied current to then determine the pressure that will be regulated at port (3). Oil is supplied from port (2) to port (3) until desired pressure is reached. If pressure at port (3) exceeds desired level, excess oil is vented to port (1) until desired level is reached.Pressures at port (1) are additive to regulated pressure at port (3).

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe

PRESSURE CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

EF-PRP 3 Way 2 Position, Pilot Operated, Pressure Reducing, Relieving ValveDESCRIPTION10 size, 7/8-14 thread, “Delta” series, pilot operated, 3 way 2 position, proportional pressure reducing/relieving valve

OPERATIONWhen de-energized and with a passive load at port (3), the EF-PRP passes sufficient flow from port (2) to port (3) to regulate a minimum pressure of approximately 3-10 Bar (45-145 PSI). With a supplied flow from an external source into port (3) the valve will regulate the minimum pressure as shown on curve below by bypassing flow to port (1).

When energized, the actuator creates a force proportional to the applied current to then determine the pressure that will be regulated at port (3). Oil is supplied from port (2) to port (3) until desired pressure is reached. If pressure at port (3) exceeds desired level, excess oil is vented to port (1) until desired level is reached.

Pressures at port (1) are additive to regulated pressure at port (3).

FEATURES• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

HYDRAULIC SYMBOL VALVE SPECIFICATIONSNominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3000 PSI (207 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temperature Range -40° to 250° F (-40° to 120° C)

Weight .59 lbs. (.27 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)

Cavity DELTA 3WPERFORMANCE Cavity Form Tool (Finishing) 40500001

Actual Test Data (Cartridge Only) Seal Kit 21191206

0 100 200 300 400 500

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 200 400 600 800 1000

Current (mA) at 24 VDC

Reg

ulat

ed P

ress

ure

(BA

R)

Reg

ulat

ed P

ress

ure

(PSI

)

Current (mA) at 12 VDCEF-PRP-0A EF-PRP-0B EF-PRP-0C

(100%)

(100%)

0 10 20 30 40 50 60

0

50

100

150

200

0

500

1000

1500

2000

2500

3000

0 2 4 6 8 10 12 14 16

Flow (LPM)Pr

essu

re (B

AR

)

Reg

ulat

ed P

ress

ure

(PSI

)

Flow (GPM)

Port 2 to 3 @ 36% Port 2 to 3 @ 69% Port 2 to 3 @ 90%

EF-PRP-0C

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3000 PSI (207 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .59 lbs (.27 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Cavity DELTA 3WCavity Form Tool (Finishing) 40500001Seal Kit 21191206

VALVE SPECIFICATIONSHYDRAULIC SYMBOL

PERFORMANCE

1

2

3

Page 12: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD11

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

PRESSURE CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

0 10 20 30 40 50 60

0

5

10

15

20

25

30

35

40

0

100

200

300

400

500

600

0 2 4 6 8 10 12 14 16

Flow (LPM)

Pres

sure

(BA

R)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Port 2 to 3 Port 3 to 1

0 10 20 30 40 50 60

0

50

100

150

200

0

500

1000

1500

2000

2500

3000

0 2 4 6 8 10 12 14 16

Flow (LPM)

Reg

ulat

ed P

ress

ure

(BA

R)

Reg

ulat

ed P

ress

ure

(PSI

)

Flow (GPM)

Port 3 to 1 @ 360 mA Port 3 to 1 @ 690 mA Port 3 to 1 @ 900 mA

ORDERING INFORMATIONEF-PRP - - - -

OPTIONS BODIESBuna, 150-1015 PSI range 0A Blank Without BodyViton, 150-1015 PSI range VA N 1/4 NPTF PortsBuna, 150-2175 PSI range 0B S #6 SAE PortsViton, 150-2175 PSI range VBBuna, 150-3000 PSI range 0C

Viton, 150-3000 PSI range VC VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC

“P” COIL TERMINATION 22 220 VAC(All DC Except as Noted) 44 440 VAC

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC)PL Packard on Leads CL Conduit Lead – (AC Only)WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .30 lbs/.14 kg.

PRESSURE CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

0 10 20 30 40 50 60

0

5

10

15

20

25

30

35

40

0

100

200

300

400

500

600

0 2 4 6 8 10 12 14 16

Flow (LPM)

Pres

sure

(BA

R)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Port 2 to 3 Port 3 to 1

0 10 20 30 40 50 60

0

50

100

150

200

0

500

1000

1500

2000

2500

3000

0 2 4 6 8 10 12 14 16

Flow (LPM)

Reg

ulat

ed P

ress

ure

(BA

R)

Reg

ulat

ed P

ress

ure

(PSI

)

Flow (GPM)

Port 3 to 1 @ 360 mA Port 3 to 1 @ 690 mA Port 3 to 1 @ 900 mA

ORDERING INFORMATIONEF-PRP - - - -

OPTIONS BODIESBuna, 150-1015 PSI range 0A Blank Without BodyViton, 150-1015 PSI range VA N 1/4 NPTF PortsBuna, 150-2175 PSI range 0B S #6 SAE PortsViton, 150-2175 PSI range VBBuna, 150-3000 PSI range 0C

Viton, 150-3000 PSI range VC VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC

“P” COIL TERMINATION 22 220 VAC(All DC Except as Noted) 44 440 VAC

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC)PL Packard on Leads CL Conduit Lead – (AC Only)WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .30 lbs/.14 kg.

0 10 20 30 40 50

0

5

10

15

20

25

0

50

100

150

200

250

300

350

400

0 2 4 6 8 10 12 14

Flow (LPM)

Pres

sure

(BA

R)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Port 2 to 3 Port 3 to 1

0 10 20 30 40

0

50

100

150

200

0

500

1000

1500

2000

2500

3000

0 2 4 6 8 10 12

Flow (LPM)Re

gula

ted

Pres

sure

(BA

R)

Reg

ulat

ed P

ress

ure

(PSI

)

Flow (GPM)

Port 3 to 1 @ 360 mA Port 3 to 1 @ 690 mA Port 3 to 1 @ 900 mA

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna, 150-1015 PSI range 0A Blank Without BodyViton, 150-1015 PSI range VA N 1/4” NPTF PortsBuna, 150-2175 PSI range 0B S #6 SAE PortsViton, 150-2175 PSI range VBBuna, 150-3000 PSI range 0CViton, 150-3000 PSI range VC VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC

“P” COIL TERMINATION 22 220 VAC44 440 VAC

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC & DC)PL Packard on Leads CL Conduit Lead – (AC Only)WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

EF-PRP – – – – Approximate Coil Weight: .30 lbs (.14 kg)

Page 13: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD12

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

IP-PRZ-59-AM12 PILOT OPERATED PROPORTIONAL, PRESSURE REDUCING/RELIEVING, SLIP-IN TYPE

DESCRIPTIONSpecial cavity, flange retained, slip-in proportional pressure reducing/relieving valve.

OPERATIONThe IP-PRZ-59-AM12 generates a variable pressure in response to a PWM (Pulse Width Modulated) current signal. With no current applied to the proportional solenoid, the inlet port 3 (P) is blocked and the regulated port 2 (U) is vented to port 1 (T). As current is increased, fluid pressure is proportionally controlled at the regulated port 3 (P). On attainment of proportionally determined pressure at 2 (U), the cartridge shifts to block flow at 3 (P), thereby regulating pressure at 2 (U). In this mode, the valve also will relieve 2 (U) to 1 (T) at a variable value over the set reducing pressure.

FEATURES • Economical slip-in style.• Integral waterproof coil.• Efficient wet-armature construction.• Hardened parts for long life.

Nominal Flow 7.9 GPM (30 LPM) @ 3 bar DeltaPMax Inlet Pressure 700 PSI (50 bar)Controlled Pressure Range (see graph)Max Internal Leakage <500 cc/min @ 35 barViscosity Range 5 to 5000 cStFiltration ISO 18/15/13Media Operating Temp. Range -25°C / +85°CWeight .63 lbs (.29 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity T059Cavity Tools Kit(form tool, reamer, tap) K-T059Flange Mounting Screws and Torque M6x10 / 4 ft-lbs (6 Nm)

VALVE SPECIFICATIONS

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 100-900 mAPWM or Super-ImposedDither Frequency 100-150 HzCoil Resistance (12 VDC) 10 Ohm ±5% at 68°F (20°C)Max Power Consumption 14 WattProtection Degree IP 67 according to IEC 529Coil Termination AMP Superseal 1.5 Series 282080-1 TypeColor Connectors Green

COIL SPECIFICATIONS

Flanged Retained Product. The coil (12 VDC) is an integral part of the valve and is not serviceable. Inlet pressure up to 50 bar.Max regulated pressure can be increased up to 35 bar (factory preset). Tank Pressure level above zero is additive to the valves expected reduced pressure value.

HYDRAULIC SYMBOL

PERFORMANCE

Red

uced

Pre

ssur

e (b

ar)

Current (mA)Curve is attained with SAE 40 - Grade oil @ 50°C

Reduced pressure (bar) vs. Current (mA)12 V coil, 24 bar inlet pressure

Page 14: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD13

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

IP-PRZ-59-AM12 – –

OPTIONS BODIESBuna Standard 00 Blank Without Body

Buna, Screen A0 S #6 SAE Ports

DIMENSIONS

ORDERING INFORMATION

Page 15: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD14

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EG-PRZ 3 WAY, PROPORTIONAL PRESSURE REDUCING CONTROL VALVE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, proportional pressure reducing control valve.

OPERATIONWhen de-energized the EG-PRZ allows flow from (2) to (1) and blocks flow at (3). When energized, the cartridge’s spool lifts to open (3) to (2) and blocks flow at (1). Outlet pressure is proportional to current applied to the coil.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 8 GPM (30 LPM) Max System Pressure 450 PSI (31 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .38 lbs (.17 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 12 ft-lbs (16.3 Nm)Coil Nut Torque Requirements 4 - 6 ft-lbs (5.4 - 8.1 Nm)Cavity DELTA 4WCavity Form Tool (Finishing) 40500002Seal Kit 21191204

VALVE SPECIFICATIONS

HYDRAULIC SYMBOL

PERFORMANCE

Pressure vs. Current Graph for EG-PRZ at 300 Psi Inlet Pressure

0

60

120

180

240

300

0 20 40 60 80 100

Pressure vs Current Graph for EGPRZ at 300 psi inlet pressure

% of Maximum Control Current

Pres

sure

(PSI

)

0

5

10

15

20Pr

essu

re (B

AR

)

0

60

120

180

240

300

0 20 40 60 80 100

Pressure vs Current Graph for EGPRZ at 300 psi inlet pressure

% of Maximum Control Current

Pres

sure

(PSI

)

0

5

10

15

20

Pres

sure

(BA

R)

Low Wattage coils are available. Consult Factory

Page 16: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD15

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONSDIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE12 12 VDC (.825 Amps Max.)24 24 VDC (.412 Amps Max.)

“P” COIL TERMINATION(All DC Except as Noted)

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (DC)PL Packard on Leads DI Deutsch - Integral DT04-2PWL Weatherpack on Leads

EG-PRZ – – – –

Page 17: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD16

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

ES-PRZ PROPORTIONAL PRESSURE REDUCING CONTROL VALVE

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, proportional pressure reducing control valve.

OPERATIONWhen de-energized the ES-PRZ allows flow from (2) to (1) and blocks flow at (3). When energized, the cartridge’s spool lifts to open (3) to (2) and blocks flow at (1). Outlet pressure is proportional to current applied to the coil.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Low Wattage coils available. Consult Factory.

Nominal Flow 30 GPM (114 LPM)Max System Pressure 450 PSI (31 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .67 lbs (.3 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity 40200043

VALVE SPECIFICATIONS

HYDRAULIC SYMBOL

PERFORMANCE

1

2

3

0

60

120

180

240

Pressure vs Current Graph for ESPRZ at 300 PSI inlet

300

0 8020 40 60 100

Pre

ssur

e (P

SI)

0

5

% of Maximum Control Current

10

15

20

Pre

ssur

e (B

AR

)

1

2

3

0

60

120

180

240

Pressure vs Current Graph for ESPRZ at 300 PSI inlet

300

0 8020 40 60 100

Pre

ssur

e (P

SI)

0

5

% of Maximum Control Current

10

15

20

Pre

ssur

e (B

AR

)

Pre

ssur

e (P

SI)

Pressure vs. Current Graph for ESPRZ at 300 PSI inlet

% of Maximum Control Current

Pre

ssur

e (B

AR

)

Page 18: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD17

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 - Consult Factory

VOLTAGE12 12 VDC (.825 Amps Max.)

“P” COIL TERMINATION 24 24 VDC (.412 Amps Max.)(All DC Except as Noted)

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) – (DC)PL Packard on Leads DI Deutsch – Integral DT04-2PWL Weatherpack on Leads

ES-PRZ – – – – Approximate Coil Weight: .42 lbs (.19 kg)

Page 19: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD18

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 20: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD19

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

NORMALLY CLOSED GPM PSI LPM BAR CAVITY MODEL PAGE

20 3000 76 207 7/8-14 EE-PRB PD20

PROPORTIONAL PRESSURE RELIEF VALVES

NORMALLY OPEN GPM PSI LPM BAR CAVITY MODEL PAGE

12 3000 45 207 7/8-14 EE-PRD PD22

Typical application for the PRL and PRB is for fan or motor speed control.

TYPICAL SCHEMATIC

Page 21: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD20

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EE-PRB 2 WAY NORMALLY CLOSED, PROPORTIONAL RELIEF VALVE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated spool type relief valve.

OPERATIONThe EE-PRB blocks flow from (2) to (1) until sufficient pressure is present at (2) to offset a spring induced force. As solenoid current is increased, it offsets a portion of this force, resulting in a lower relief pressure. Can be infinitely adjusted across a prescribed range in response to a PWM (Pulse Width Modulated) current. Pressure output is inversely proportional to the current input. With full current applied to the solenoid, the valve will free flow from (2) to (1), at approximately 100 PSI (7 bar).Note: backpressure on port (1) becomes additive to the pressure setting at a 1:1 ratio.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

1

2

1

2

Nominal Flow 0÷20 GPM (0÷76 LPM)Operating Range 100-3000 PSI (7-207 bar)Typical Hysteresis 10% MaxViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .62 lbs (.28 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 2WCavity Tools Kit(form tool, reamer, tap) 40500000Seal Kit 21191202

VALVE SPECIFICATIONS

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 100÷1000 mAPWM or Super-ImposedDither Frequency 120÷200 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

COIL SPECIFICATIONS

Great for fan drive motor control.

HYDRAULIC SYMBOL

PERFORMANCE

Rel

ief P

ress

ure

(bar

)

Current (mA)Coil 12 VDC

Relief pressure vs. CurrentCostant flow 10 LPM (2.6 GPM)

Page 22: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD21

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

(for bodies style and sizes see section “Accessories”)0,

87 [

22]

Hex

.

3,58

[91

]1,

25 [

31,8

]

1,97

[50

]

Hex. 1,06 [27]

7/8-14 UNF - 2A

1,46 [37]

1,04 [26,5]

1,77 [45]

SEE COIL DATA FOR TERMINATIONS

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna, 100-1015 PSI range (7-70 bar) 0A Blank Without BodyViton, 100-1015 PSI range (7-70 bar) VA N 3/8” BSP Ports

S #8 SAE PortsBuna, 100-2175 PSI range (7-150 bar) 0BViton, 100-2175 PSI range (7-150 bar) VB

Buna, 100-3000 PSI range (7-207 bar) 0CViton, 100-3000 PSI range (7-207 bar) VC VOLTAGE (other voltages available on request)

12 12 VDC24 24 VDC

“F” COIL TERMINATION

DIN 43650 (Hirschmann) HCDeutsch - Integral DT04-2P DI

AMP Jr. Timer JT

EE-PRB – – – – Approximate Coil Weight: .47 lbs (.21 kg)

Great for fan drive motor control. 1

2

1

2

Rel

ief P

ress

ure

(bar

)R

elie

f Pre

ssur

e (b

ar)

Rel

ief P

ress

ure

(PS

I)R

elie

f Pre

ssur

e (P

SI)

Flow (LPM)

Flow (GPM)

Flow (GPM)

Flow (LPM)

Relief pressure vs. Flow - No current appliedCostant flow 10 LPM (2.6 GPM)

Pressure Drop vs. FlowCoil energized

Page 23: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD22

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 48 / 2018

EE-PRD 2 WAY NORMALLY OPEN, PROPORTIONAL RELIEF VALVE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally open, hydraulic relief valve.

OPERATIONThe EE-PRD blocks flow from (2) to (1) until sufficient pressure is present at (2) to offset the electrically induced solenoid force. Can be infinitely adjusted across a prescribed range using a variable electric input. Pressure output is proportional to DC current input. This valve is intended for use as a pressure limiting device in demanding applications.With no current applied to the solenoid, the valve will free flow from (2) to (1) at approximately 50 PSI.Note: backpressure on port (1) becomes additive to the pressure setting at a 1:1 ratio.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

0 100 200 300 400 500

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 200 400 600 800 1000

Current (mA) @ 24 VDC

Rel

ief P

ress

ure

(BA

R)

Rel

ief P

ress

ure

(PSI

)

Current (mA) @ 12 VDC

Relief Pressure vs. Current

EE-PRD-0A EE-PRD-0B EE-PRD-0C

0 100 200 300 400 500

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 200 400 600 800 1000

Current (mA) @ 24 VDC

Rel

ief P

ress

ure

(BA

R)

Rel

ief P

ress

ure

(PSI

)

Current (mA) @ 12 VDC

Relief Pressure vs. Current

EE-PRD-0A EE-PRD-0B EE-PRD-0C

Nominal Flow 0-20 GPM (0-76 LPM)Operating Range 50-3000 PSI (3-207 bar)Typical Hysteresis 5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .30 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit(form tool, reamer, tap) 40500000Seal Kit 21191202

VALVE SPECIFICATIONS

If low voltage is expected on the machine, 12 or 24 Volt systems will require the use of 10 volt or 20 volt coils respectively. Consult Factory for availability of these coil options.

For best performance valve must be purged of air.Locate below reservoir or add check valve to return.Recommended vehicle installation is Tube Up or Horizontal after purging. Fastest purging position during bleed/start-up is with tube up. PWM frequency: 100-200 Hz (200 Hz recommended). For lower minimum or other ranges consult factory.

HYDRAULIC SYMBOL

PERFORMANCE

Rel

ief P

ress

ure

(PS

I)

Rel

ief P

ress

ure

(bar

)

Relief Pressure vs. CurrentCurrent (mA) @ 24 VDC

Current (mA) @ 12 VDC

Page 24: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD23

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

8 /

2018

0 20 40 60 80

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)

Rel

ief P

ress

ure

(PSI

)

Rel

ief P

ress

ure

(PSI

)

Flow (GPM)

Relief Pressure vs. Flow @ 1 amp

EE-PRD-0A EE-PRD-0B EE-PRD-0C

0 20 40 60 80

0

4

8

12

16

0

50

100

150

200

250

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)Pr

essu

re D

rop

(BA

R)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Pressure Drop vs. Flow

0 20 40 60 80

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)

Rel

ief P

ress

ure

(PSI

)

Rel

ief P

ress

ure

(PSI

)

Flow (GPM)

Relief Pressure vs. Flow @ 1 amp

EE-PRD-0A EE-PRD-0B EE-PRD-0C

0 20 40 60 80

0

4

8

12

16

0

50

100

150

200

250

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)Pr

essu

re D

rop

(BA

R)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Pressure Drop vs. Flow

0 20 40 60 80

0

40

80

120

160

200

240

0

500

1000

1500

2000

2500

3000

3500

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)

Rel

ief P

ress

ure

(PSI

)

Rel

ief P

ress

ure

(PSI

)

Flow (GPM)

Relief Pressure vs. Flow @ 1 amp

EE-PRD-0A EE-PRD-0B EE-PRD-0C

0 20 40 60 80

0

4

8

12

16

0

50

100

150

200

250

0 2 4 6 8 10 12 14 16 18 20 22

Flow (LPM)

Pres

sure

Dro

p (B

AR

)

Pres

sure

Dro

p (P

SI)

Flow (GPM)

Pressure Drop vs. Flow

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna, 100-1200 PSI range 0A Blank Without BodyViton, 100-1200 PSI range VA N 3/8” NPT PortsBuna, 100-2175 PSI range 0B S #8 SAE PortsViton, 100-2175 PSI range VBBuna, 100-3000 PSI range 0CViton, 100-3000 PSI range VC VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC

“P” COIL TERMINATION 48 48 VDC

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) PL Packard on Leads DI Deutsch – Integral DT04-2PWL Weatherpack on Leads

EE-PRD – – – – Approximate Coil Weight: .74 lbs (.33 kg)

Rel

ief P

ress

ure

(PS

I)P

ress

ure

Dro

p (P

SI)

Rel

ief P

ress

ure

(BA

R)

Pre

ssur

e D

rop

(BA

R)

Relief Pressure vs. Flow @ 4 AmpFlow (LPM)

Pressure Drop vs. Flow Flow (LPM)

Flow (GPM)

Flow (GPM)

Page 25: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD24

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 26: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD25

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

SPOOL TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

13.2 3500 50 241 7/8-14 EE-P2G PD26

23.7 3500 90 241 1 1/16-12 ET-P2S PD28

2 WAY NORMALLY CLOSED PROPORTIONAL FLOW CONTROL VALVES

POPPET TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

6.5 3500 25 241 3/4-16 EB-P2A PD30

12 3500 45 241 7/8-14 EE-P2A PD32

29 3500 110 241 1 1/16-12 ET-P2A PD34

Page 27: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD26

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

Flow vs. Current - “A” VersionCoil 12 VDC - Delta P = 14 bar - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Q (l/min)

l (mA)

EE-P2G 2 WAY NORMALLY CLOSED, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, proportional flow controlvalve.

OPERATIONWhen de-energized the EE-P2G blocks flow at ports (1) and (2). When energized, the valve allows flow from (2) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release turn the manual override screw counterclockwise.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage Max 50 cc/min at 245 barHysteresis ±3%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .58 lbs (.26 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 26 ft-lbs (35 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 2WCavity Tools Kit(form tool, reamer, tap) 40500000Seal Kit 21191200

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 200-1450 mAPWM or Super-ImposedDither Frequency 100-150 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

HYDRAULIC SYMBOL

PERFORMANCE

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curves are attained with compensator.

Page 28: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD27

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

EE-P2G – – – –

NOTES: 1) Flows refer to a 14 bar Delta P 2) For other seals, consult factory

OPTIONS BODIESBuna, Push Type Override Standard AP Up to 22 l/min Blank Without Body

Buna, Screw Type Override (Knob) AS Up to 22 l/min S #8 SAE PortsBuna, Screw Type Override (Grad. Knob) AK Up to 22 l/min

Buna, Push Type Override Standard BP Up to 50 l/minBuna, Screw Type Override (Knob) BS Up to 50 l/min

Buna, Screw Type Override (Grad. Knob) BK Up to 50 l/min VOLTAGE12 12 VDC

Buna, Push Type Override Standard CP Up to 50 l/min 24 24 VDCBuna, Screw Type Override (Knob) CS Up to 50 l/min “F” COIL TERMINATION

Buna, Screw Type Override (Grad. Knob) CK Up to 50 l/min HC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Flow vs. Current - “C” VersionCoil 12 VDC - Delta P = 14 bar - Oil 26 cSt (121 SSU) @ 50°C (104°F)

(for bodies style and sizes see section “Accessories”)

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .47 lbs (.21 kg)

Q (l/min)

l (mA)

NOTE: non linear

characteristics

Flow vs. Current - “B” VersionCoil 12 VDC - Delta P = 14 bar - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Q (l/min)

l (mA)

Page 29: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD28

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

ET-P2S 2 WAY NORMALLY CLOSED, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally closed, proportional flow controlvalve.

OPERATIONWhen de-energized the ET-P2S blocks flow at ports (2) and (1). When energized, the valve allows flow from (1) to (2). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage Max 50 cc/min at 245 barHysteresis ±3%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity TECNORD 2WCavity Tools Kit(form tool, reamer, tap) 40500032Seal Kit 21191200

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-ImposedDither Frequency 100-150 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curves are attained with Tecnord QC-CP3 compensator.

HYDRAULIC SYMBOL

PERFORMANCE

Flow vs. Current Coil 12 VDC - Press. Drop = 14 bar - Oil 46 cSt (217 SSU) @ 50°C (122°F)

Flow

(LP

M)

Flow

(GP

M)

Current (mA)

Page 30: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD29

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

UNF

DIMENSIONS

ET-P2S – – – –

NOTES: 1) Flows refer to a 14 bar Delta P 2) For other seals, consult factory

OPTIONS BODIESBuna Standard C0 Up to 90 l/min Blank Without Body

Buna, Screw Type Override (Knob) CS Up to 90 l/min N 3/4” BSP PortsBuna, Screw Type Override (Grad. Knob) CK Up to 90 l/min S #8 SAE Ports

VOLTAGE12 12 VDC24 24 VDC

“F” COIL TERMINATIONHC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

(for bodies style and sizes see section “Accessories”)

ORDERING INFORMATIONApproximate Coil Weight: .47 lbs (.21 kg)

Pressure Drop With valve fully open - Oil 46 cSt (217 SSU) @ 50°C (122°F)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Flow (GPM)

Page 31: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD30

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EB-P2A 2 WAY NORMALLY CLOSED, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION8 size, 3/4-16 thread, solenoid operated, 2 way normally closed poppet style, proportional flow control valve.

OPERATIONWhen de-energized the EB-P2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized, the valve allows flow from (1) to (2). Flow is proportional to current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow Range See curvesMax System Pressure 3500 PSI (241 bar)Leakage 0-10 drops / min @ 245 barHysteresis ±3%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity POWER 2WCavity Tools Kit(form tool, reamer, tap) 40500005Seal Kit 21191102

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 500 - 1450 mAPWM or Super-Imposed Dither Frequency 100 HzCoil Resistance (12 VDC) 7.5 Ohm ±5% at 68°F (20°C)

Pressure Drop 1 to 2 with valve completely open

Flow vs. Current at different Pressure DropCoil 12 VDC - hyd. - Oil 26 cSt (121 SSU) @ 40°C (104°F)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curves are attained without pressure compensator. The valve can work with a pressure drop up to 200 bar.

HYDRAULIC SYMBOL

PERFORMANCE

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (l/min)

Current (Amps)

Flow

(l/m

in)

Flow

(GP

M)

Flow (GPM)

Page 32: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD31

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

EB-P2A – – – –

NOTES: 1) Flows refer to a 14 bar Delta P 2) For other seals, consult factory

OPTIONS BODIESBuna Standard C0 Up to 25 l/min Blank Without Body

Buna, Screw Type Override (Knob) CS Up to 25 l/min S #8 SAE PortsBuna, Screw Type Override (Grad. Knob) CK Up to 25 l/min

VOLTAGE12 12 VDC24 24 VDC

“F” COIL TERMINATIONHC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

(for bodies style and sizes see section “Accessories”)

ORDERING INFORMATIONApproximate Coil Weight: .47 lbs (.21 kg)

Page 33: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD32

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EE-P2A 2 WAY NORMALLY CLOSED, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION10 size, 7/8-14 thread, solenoid operated, 2 way normally closed poppet style, proportional flow control valve.

OPERATIONWhen de-energized the EE-P2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized, the valve allows flow from (1) to (2). Flow is proportional to current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow Range See curves Max System Pressure 3500 PSI (241 bar)Leakage 0-10 drops / min @ 245 barHysteresis ±3%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 2WCavity Tools Kit(form tool, reamer, tap) 40500000Seal Kit 21191200

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 500-1450 mAPWM or Super-Imposed Dither Frequency 100 HzCoil Resistance (12 VDC) 7.5 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curves are attained without pressure compensator. The valve can work with a pressure drop up to 200 bar.

HYDRAULIC SYMBOL

PERFORMANCE

Pressure Drop 1 to 2 with valve completely open

Flow vs. Current at different Pressure DropPoppet type A - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (l/min)

Current (Amps)

Flow

(l/m

in)

Flow

(GP

M)

Flow (GPM)

Page 34: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD33

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

ORDERING INFORMATION

EE-P2A – – – –

NOTES: 1) Flows refer to a 14 bar Delta P 2) For other seals, consult factory

OPTIONS BODIESBuna Standard A0 Up to 15 l/min Blank Without Body

Buna, Screw Type Override (Knob) AS Up to 15 l/min S #8 SAE PortsBuna, Screw Type Override (Grad. Knob) AK Up to 15 l/min

Buna Standard B0 Up to 30 l/minBuna, Screw Type Override (Knob) BS Up to 30 l/min

Buna, Screw Type Override (Grad. Knob) BK Up to 30 l/min VOLTAGE12 12 VDC

Buna Standard C0 Up to 45 l/min 24 24 VDCBuna, Screw Type Override (Knob) CS Up to 45 l/min “F” COIL TERMINATION

Buna, Screw Type Override (Grad. Knob) CK Up to 45 l/min HC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

(for bodies style and sizes see section “Accessories”)

Flow vs. Current at different Pressure DropPoppet type B - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Flow vs. Current at different Pressure DropPoppet type C - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Current (Amps)

Current (Amps)

Flow

(l/m

in)

Flow

(GP

M)

Flow

(l/m

in)

Flow

(GP

M)

Page 35: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD34

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

ET-P2A 2 WAY NORMALLY CLOSED, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION12 size, 1 1/16-12 thread, solenoid operated, 2 way normally closed poppet style, proportional flow control valve.

OPERATIONWhen de-energized the ET-P2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized, the valve allows flow from (1) to (2). Flow is proportional to current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow vs. Current

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 0-10 drops / min @ 245 barHysteresis ±3%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity TECNORD 2WCavity Tools Kit(form tool, reamer, tap) 40500032Seal Kit 21191301

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 500 - 1450 mAPWM or Super-Imposed Dither Frequency 100 HzCoil Resistance (12 VDC) 7.5 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curves are attained without pressure compensator. The valve can work with a pressure drop up to 200 bar.

HYDRAULIC SYMBOL

PERFORMANCE

Pressure Drop 1 to 2 with valve completely open

Flow vs. Current at different Pressure DropPoppet type A - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (l/min)

Current (Amps)

Flow

(l/m

in)

Flow

(GP

M)

Flow (GPM)

Page 36: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD35

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

(for bodies style and sizes see section “Accessories”)

DIMENSIONS

ORDERING INFORMATION

ET-P2A – – – –

OPTIONS BODIESBuna Standard A0 Up to 65 l/min Blank Without Body

Buna, Screw Type Override (Knob) AS Up to 65 l/min S #8 SAE PortsBuna, Screw Type Override (Grad. Knob) AK Up to 65 l/min

Buna Standard B0 Up to 85 l/minBuna, Screw Type Override (Knob) BS Up to 85 l/min

Buna, Screw Type Override (Grad. Knob) BK Up to 85 l/min VOLTAGE12 12 VDC

Buna Standard C0 Up to 110 l/min 24 24 VDCBuna, Screw Type Override (Knob) CS Up to 110 l/min “F” COIL TERMINATION

Buna, Screw Type Override (Grad. Knob) CK Up to 110 l/min HC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTES: 1) Flows refer to a 14 bar Delta P 2) For other seals, consult factory

Flow vs. Current at different Pressure DropPoppet type B - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Flow vs. Current at different Pressure DropPoppet type C - Coil 12 VDC - hyd. oil 26 cSt (121 SSU) @ 40°C (104°F)

Current (Amps)

Current (Amps)

Flow

(l/m

in)

Flow

(GP

M)

Flow

(l/m

in)

Flow

(GP

M)

Page 37: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD36

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 38: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD37

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

SPOOL TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

8 3500 30 241 7/8-14 EE-P2H PD38

2 WAY NORMALLY OPEN PROPORTIONAL FLOW CONTROL VALVES

Page 39: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD38

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EE-P2H 2 WAY NORMALLY OPEN, PROPORTIONAL FLOW CONTROL VALVE

DESCRIPTION10 size, 7/8-14 thread, solenoid operated, 2 way normally open, proportional flow control valve.

OPERATIONWhen de-energized the EE-P2H allows flow from (1) to (2). When fully energized, the valve blocks flow at port (1) and (2). Flow is proportional to current applied to the coil. A compensator must be used to create a pressure compensated flow control function.OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release turn the manual override screw counterclockwise.

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Flow Range See curveMax System Pressure 3500 PSI (241 bar)Leakage Max 100 cc/min at 245 barHysteresis ±4%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40°C to 250°F (-40°C to 120°C)Weight .58 lbs (.26 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 26 ft-lbs (35 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 2WCavity Tools Kit(form tool, reamer, tap) 40500000Seal Kit 21191200

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 0 - 1450 mAPWM or Super-Imposed Dither Frequency 100-150 HzCoil Resistance (12 VDC) 7.5 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Curve is attained with compensator at with various settings.

HYDRAULIC SYMBOL

PERFORMANCE

Flow (l/min) vs. Current (mA)Coil 12 VDC - Delta P = 5, 14, 20 bar; Toil = 40°C

Q (l/min)

l (mA)

Page 40: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD39

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

(for bodies style and sizes see section “Accessories”)

DIMENSIONS

ORDERING INFORMATION

EE-P2H – – – –

OPTIONS BODIESBuna, Push Type Override Standard 0P Blank Without Body

Buna, Screw Type Override (Knob) 0S S #8 SAE PortsBuna, Screw Type Override (Grad. Knob) 0K

VOLTAGE12 12 VDC24 24 VDC

“F” COIL TERMINATIONHC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTE: for other seals, consult factory.

Page 41: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD40

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 42: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD41

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2 WAY NORMALLY CLOSED PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR VALVES

POPPET TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

12 3500 45 241 7/8-14 EG-F2A PD42

26 3500 100 241 1/16-12 EU-F2A PD44

Page 43: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD42

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EG-F2A 2 WAY PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, normally closed, poppet style, restrictive type 2 ways pressure compensated proportional flow regulator.

OPERATIONEG-F2A maintains a constant flow rate out of (2) regardless of load pressure variations in the circuit downstream of (1). When coil is not energized, there is no regulated flow out of (2). The valve begins to respond to load variations when the flow through the valve creates a pressure differential across the control spool.Reverse flow from (2) to (1) returns through the control spool and is not compensated.OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

FLOW (lt/min) vs. CURRENT (mA - PWM @ 100 Hz)14 bar COMPENSATED

50454035302520151050

300 400 500 600 700 800 900 1000 1200 1300 1400 1500 I (mA)

Q (l

t/min

)

FLOW (lt/min) vs. CURRENT (mA - PWM @ 100 Hz)14 bar COMPENSATED

50454035302520151050

300 400 500 600 700 800 900 1000 1200 1300 1400 1500 I (mA)

Q (l

t/min

)

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 0-10 drops / min @ 245 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°COperating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (41 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity T308Cavity Tools Kit(form tool, reamer, tap) K-T308

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-Imposed Dither Frequency 100 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Port (1) must be connected in the manifold to port (3).

HYDRAULIC SYMBOL

PERFORMANCE

Flow (lt/min) vs. Current (mA - PWM @ 100 Hz) 14 bar CompensatedQ (l/min)

l (mA)

1

2

3

Page 44: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD43

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

R e g u la t e d F lo w V s . P r e s s u r e D r o p ( b a r )

2 W a y - 1 2 V c o i l - 1 3 0 H z P W M - o i l 2 6 c S t @ 5 0 °C

5 00 1 0 0 1 5 0 2 0 0 2 5 0

Regu

late

d F

low

(l/m

in)

2 0

3 0

4 0

5 0

0

P r e s s u r e D r o p ( b a r )

1 0

Regulated Flow vs. PressureCoil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

R e g u la t e d F lo w V s . P r e s s u r e D r o p ( b a r )

2 W a y - 1 2 V c o i l - 1 3 0 H z P W M - o i l 2 6 c S t @ 5 0 °C

5 00 1 0 0 1 5 0 2 0 0 2 5 0

Regu

late

d F

low

(l/m

in)

2 0

3 0

4 0

5 0

0

P r e s s u r e D r o p ( b a r )

1 0

DIMENSIONS

ORDERING INFORMATION

(for bodies style and sizes see section “Accessories”)

EG-F2A – – – –

OPTIONS BODIESBuna Standard A0 Up to 15 l/min Blank Without Body

Buna, Screw Type Override (Knob) AS Up to 15 l/min N 3/8” BSP PortsBuna, Screw Type Override (Grad. Knob) AK Up to 15 l/min S #6 SAE Ports

Buna Standard B0 Up to 30 l/minBuna, Screw Type Override (Knob) BS Up to 30 l/min

Buna, Screw Type Override (Grad. Knob) BK Up to 30 l/min VOLTAGE12 12 VDC

Buna Standard C0 Up to 45 l/min 24 24 VDCBuna, Screw Type Override (Knob) CS Up to 45 l/min “F” COIL TERMINATION

Buna, Screw Type Override (Grad. Knob) CK Up to 45 l/min HC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTE: for other seals, consult factory.

Pressure Drop (bar)

Reg

ulat

ed F

low

(l/m

in)

2

3

Page 45: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD44

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

EU-F2A 2 WAY PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR

DESCRIPTION12 size, 1” 1/16-12 thread, “Tecnord” series, solenoid operated, normally closed, poppet style, restrictive type 2 ways pressure compensated proportional flow regulator.

OPERATIONEU-F2A maintains a constant flow rate out of (2) regardless of load pressure variations in the circuit downstream of (1). When coil is not energized, there is no regulated flow out of (2). The valve begins to respond to load variations when the flow through the valve creates a pressure differential across the control spool.Reverse flow from (2) to (1) returns through the control spool and is not compensated. The manual override increases flow by counter-clockwise rotation of the manual override knob.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

Regulated Flow vs. Pressure

Flow vs. Current

1

2

3

Regulated Flow vs. Pressure

Flow vs. Current

1

2

3

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 0-10 drops / min @ 245 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity TECNORD 3WCavity Tools Kit(form tool, reamer, tap) 40500034

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 500-1400 mAPWM or Super-Imposed Dither Frequency 100 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

Port (1) must be connected in the manifold to port (3).

HYDRAULIC SYMBOL

PERFORMANCE

Regulated Flow vs. Pressure

Pressure Drop 1-2 bar

Reg

ulat

ed F

low

(l/m

in)

23

Page 46: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD45

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

Regulated Flow vs. Pressure

Flow vs. Current

1

2

3

DIMENSIONS

ORDERING INFORMATION

(for bodies style and sizes see section “Accessories”)

EU-F2A – – – –

OPTIONS BODIESBuna Standard A0 Up to 55 l/min Blank Without Body

Buna, Screw Type Override (Knob) AS Up to 55 l/min N 3/4” BSP PortsBuna, Screw Type Override (Grad. Knob) AK Up to 55 l/min S #8 SAE Ports

Buna Standard B0 Up to 75 l/minBuna, Screw Type Override (Knob) BS Up to 75 l/min

Buna, Screw Type Override (Grad. Knob) BK Up to 75 l/min VOLTAGE12 12 VDC

Buna Standard C0 Up to 100 l/min 24 24 VDCBuna, Screw Type Override (Knob) CS Up to 100 l/min “F” COIL TERMINATION

Buna, Screw Type Override (Grad. Knob) CK Up to 100 l/min HC DIN 43650 (Hirschmann)DI Deutsch-Integral DT04-2PJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTE: for other seals, consult factory.

Flow vs. Current Coil 12 VDC - Oil 26 cSt (121 SSU) @ 40°C (104°F)

Current (mA)

Flow

(l/m

in)

Page 47: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD46

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 48: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD47

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

SPOOL TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

1 2

3

1 2

3

6 3500 23 241 7/8-14 EF-F3G PD48

16 3500 60 241 1/16-12 EU-F3G PD50

3 WAY NORMALLY CLOSED PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR VALVES

Page 49: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD48

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, normally closed, spool style, 3 ways priority type pressure compensated proportional flow regulator. It can also be used as a restrictive-type 2 way, pressure-compensated flow regulator when the bypass line (port 2) is blocked.

OPERATIONEF-F3G maintains a constant flow rate out of (1) regardless of load pressure variations in the circuit downstream of (3) and regardless bypass pressure variations in the circuit downstream of (2). Excess flow bypasses out of (2). When coil is not energized, there is no regulated flow out of (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

0 300 600

10

5

15

900

Current (mA)

Flow vs. Current

20

25

Flo

w (

l/m

in)

30

1200

Type B

1400

Reg

ula

ted

Flo

w (

l/m

in)

10

15

5

20

25

30

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port (bar)

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

250 100 200 50 150

0Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

Regulated Flow Vs. Pressure Drop (bar)

2 W ay - 12 V coil - 130 Hz PW M - oil 26 cSt @ 50°C

500 100 150 200 250

Re

gula

ted

Flo

w (

l/m

in)

5

10

15

20

25

30

0

Pressure Drop (bar)

1 2

3

1 2

3

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 10 cu-in/min @ 3000 PSI 160 cc/min @ 207 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .49 lbs (.22 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (41 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 3WCavity Tools Kit(form tool, reamer, tap) 40500001

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-Imposed Dither Frequency 120-140 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

Type B

14001000600400

Flow vs. CurrentCoil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Flow

(l/m

in)

Current (mA)

EF-F3G 3 WAY PRESSURE COMPENSATED PRIORITY TYPE PROPORTIONAL FLOW REGULATOR

VALVE SPECIFICATIONS

COIL SPECIFICATIONS

It can be used as a restrictive 2-way pressure-compensated flow control valve, blocking bypass line port (2).

HYDRAULIC SYMBOL

PERFORMANCE

Page 50: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD49

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

P re s s u re D ro p f ro m 3 to 2

1 00

5

1 0

1 5

2 0

2 5

0

F lo w ( l/m in )

2 0 3 0

P re s s u re D ro p f ro m 3 to 2

1 00

5

1 0

1 5

2 0

2 5

0

F lo w ( l/m in )

2 0 3 0

0 300 600

10

5

15

900

Current (mA)

Flow vs. Current

20

25

Flo

w (

l/m

in)

30

1200

Type B

1400

Reg

ula

ted

Flo

w (

l/m

in)

10

15

5

20

25

30

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port (bar)

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

250 100 200 50 150

0Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

Regulated Flow Vs. Pressure Drop (bar)

2 W ay - 12 V coil - 130 Hz PW M - oil 26 cSt @ 50°C

500 100 150 200 250

Re

gula

ted

Flo

w (

l/m

in)

5

10

15

20

25

30

0

Pressure Drop (bar)

Regulated Flow vs. Pressure2 WAYS - Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Pressure Drop 3→2 (bar) Oil 26 cSt (121 SSU) @ 50°C (104°F)

DIMENSIONS

ORDERING INFORMATION

(for bodies style and sizes see section “Accessories”)

EF-F3G – – – –

OPTIONS BODIESBuna Standard B0 Up to 25 l/min Blank Without Body

Buna, Screw Type Override (Knob) BS Up to 25 l/min N 3/8” BSP PortsBuna, Screw Type Override (Grad. Knob) BK Up to 25 l/min S #6 SAE Ports

“F” COIL TERMINATION VOLTAGEHC DIN 43650 (Hirschmann) 12 12 VDCDI Deutsch-Integral DT04-2P 24 24 VDCJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTES: 1) For other flow settings, consult factory. 2) For other seals, consult factory.

Reg

ulat

ed F

low

(l/m

in)

Pressure Drop (bar)

0 300 600

10

5

15

900

Current (mA)

Flow vs. Current

20

25

Flo

w (

l/m

in)

30

1200

Type B

1400

Reg

ula

ted

Flo

w (

l/m

in)

10

15

5

20

25

30

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port (bar)

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

250 100 200 50 150

0Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

Regulated Flow Vs. Pressure Drop (bar)

2 W ay - 12 V coil - 130 Hz PW M - oil 26 cSt @ 50°C

500 100 150 200 250

Re

gula

ted

Flo

w (

l/m

in)

5

10

15

20

25

30

0

Pressure Drop (bar)

Pres. Compensation from Inlet to Work Port or Bypass Port 3 WAYS - Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Reg

ulat

ed F

low

(l/m

in)

Pressure Drop (bar)

Bypass higher than priority Priority higher than bypass

Flow (l/min)

Pre

ssur

e (b

ar)

Page 51: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD50

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION12 size, 1” 1/16-12 thread, “Tecnord” series, solenoid operated, normally closed, spool style, 3 ways priority type pressure compensated proportional flow regulator. It can also be used as a restrictive-type 2 way, pressure-compensated flow regulator when the bypass line (port 2) is blocked.

OPERATIONEU-F3G maintains a constant flow rate out of (1) regardless of load pressure variations in the circuit downstream of (3) and regardless bypass pressure variations in the circuit downstream of (2). Excess flow bypasses out of (2). When coil is not energized, there is no regulated flow out of (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

0 300 600

20

10

30

900

Current (mA)

Flow vs. Current

40

50

Flo

w (

L/m

in)

60

Type C

1200

70

1500 1800

80

Reg

ula

ted F

low

(l/m

in)

250

20

30

10

100 200 50

40

50

150

0

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port [bar]

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

70

Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

60

100

Pre

ssure

(ba

r)

5

10

15

20

25

30

0

Flow (l/min)

20 30 40 50 60 70 80 90 100

Pressure Drop from 3 to 2

110 120

0 300 600

20

10

30

900

Current (mA)

Flow vs. Current

40

50

Flo

w (

L/m

in)

60

Type C

1200

70

1500 1800

80

Reg

ula

ted F

low

(l/m

in)

250

20

30

10

100 200 50

40

50

150

0

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port [bar]

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

70

Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

60

100

Pre

ssure

(ba

r)

5

10

15

20

25

30

0

Flow (l/min)

20 30 40 50 60 70 80 90 100

Pressure Drop from 3 to 2

110 120

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 15.7 cu-in/min @ 3000 PSI 250 cc/min @ 207 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .75 lbs (.34 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 37 ft-lbs (50 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity TECNORD 3WCavity Tools Kit(form tool, reamer, tap) 40500034

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-Imposed Dither Frequency 120-140 HzCoil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)

EU-F3G 3 WAY PRESSURE COMPENSATED PRIORITY TYPE PROP. FLOW REGULATOR

COIL SPECIFICATIONS

VALVE SPECIFICATIONS

It can be used as a restrictive 2-way pressure-compensated flow control valve, blocking bypass line port (2).

1 2

3

1 2

3

HYDRAULIC SYMBOL

PERFORMANCE

Flow vs. CurrentCoil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Flow

(l/m

in)

Current (mA)

Page 52: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD51

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

Regulated Flow Vs. Pressure Drop (bar)

2 W ay - 12 V coil - 130 Hz PW M - oil 26 cSt @ 50°C

500 100 150 200 250

Reg

ula

ted F

low

(l/m

in)

10

20

30

40

50

0

Pressure Drop (bar)

70

60

DIMENSIONS

ORDERING INFORMATION

(for bodies style and sizes see section “Accessories”)

EU-F3G – – – –

OPTIONS BODIESBuna Standard C0 Up to 60 l/min Blank Without Body

Buna, Screw Type Override (Knob) CS Up to 60 l/min N 3/4” BSP PortsBuna, Screw Type Override (Grad. Knob) CK Up to 60 l/min S #8 SAE Ports

“Z” COIL TERMINATION VOLTAGEHC DIN 43650 (Hirschmann) 12 12 VDCDI Deutsch-Integral DT04-2P 24 24 VDCJT AMP Jr. Timer

Approximate Coil Weight: .47 lbs (.21 kg)

NOTES: 1) For other flow settings, consult factory. 2) For other seals, consult factory.

0 300 600

20

10

30

900

Current (mA)

Flow vs. Current

40

50

Flo

w (

L/m

in)

60

Type C

1200

70

1500 1800

80

Reg

ula

ted F

low

(l/m

in)

250

20

30

10

100 200 50

40

50

150

0

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port [bar]

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

70

Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

60

100

Pre

ssure

(ba

r)

5

10

15

20

25

30

0

Flow (l/min)

20 30 40 50 60 70 80 90 100

Pressure Drop from 3 to 2

110 120

0 300 600

20

10

30

900

Current (mA)

Flow vs. Current

40

50

Flo

w (

L/m

in)

60

Type C

1200

70

1500 1800

80

Reg

ula

ted F

low

(l/m

in)

250

20

30

10

100 200 50

40

50

150

0

50 100 150 200 250

Pressure Compensation from Intel to Work port or By-pass port [bar]

12 V coil - 130 Hz PWM - oil 26 cSt @ 50°C

0

70

Bypass higher than priority Priority higher than bypass

Pressure Drop (Bar)

60

100

Pre

ssure

(ba

r)

5

10

15

20

25

30

0

Flow (l/min)

20 30 40 50 60 70 80 90 100

Pressure Drop from 3 to 2

110 120

Regulated Flow Vs. Pressure Drop (bar)

2 W ay - 12 V coil - 130 Hz PW M - oil 26 cSt @ 50°C

500 100 150 200 250

Reg

ula

ted F

low

(l/m

in)

10

20

30

40

50

0

Pressure Drop (bar)

70

60

Regulated Flow vs. Pressure2 WAYS - Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Pressure Drop 3→2 (bar) Oil 26 cSt (121 SSU) @ 50°C (104°F)

Reg

ulat

ed F

low

(l/m

in)

Pressure Drop (bar)

Pres. Compensation from Inlet to Work Port or Bypass Port 3 WAYS - Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)

Reg

ulat

ed F

low

(l/m

in)

Pressure Drop (bar)

Bypass higher than priority Priority higher than bypass

Flow (l/min)

Pre

ssur

e (b

ar)

Page 53: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD52

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 54: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD53

PROPORTIONAL CONTROLSW

40

/ 20

18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

MOTOR SPOOL TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

(3) (1)

(2) (4)

3 3500 11 241 3/4-16 EQ-S4M PD54

6 3500 23 241 7/8-14 EG-S4M PD56

CYLINDER SPOOL TYPE GPM PSI LPM BAR CAVITY MODEL PAGE

(3) (1)

(2) (4)

3 3500 11 241 3/4-16 EQ-S4P PD58

6 3500 23 241 7/8-14 EG-S4P PD60

4W/3P PROPORTIONAL DIRECTIONAL CONTROL VALVES

Page 55: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD54

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, Motor Spool, proportional directional valve.

OPERATIONEQ-S4M, when de-energized, blocks flow at (2) and allows flow between (1), (3) and (4). When coil (S1) is energized, flow is allowed from (3) to (4), and from (2) to (1). When coil (S2) is energized, flow is allowed from (3) to (2), and from (4) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Re

gu

late

d F

low

(L

/min

)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

EQ-S4M 4 WAY 3 POSITION, MOTOR SPOOL, PROPORTIONAL DIRECTIONAL VALVE

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Re

gu

late

d F

low

(L

/min

)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 10 cu-in/min 160 cc/min bar @ 210 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°COperating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 18 ft-lbs (26 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity POWER 4WCavity Tools Kit(form tool, reamer, tap) 40500029

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1300 mAPWM or Super-Imposed Dither Frequency 100-200 HzCoil Resistance (12 VDC) 6.85 Ohm ±5% at 68°F (20°C)

COIL SPECIFICATIONS

VALVE SPECIFICATIONSHYDRAULIC SYMBOL

PERFORMANCE

Flow

(l/m

in)

Current (mA)

Flow vs. CurrentCoil 12VDC – 100 Hz PWM – Oil 26cSt (121 SSU) @ 50°C (122°F)Operating curves made with circuit having a pressure drop of 14bar

(3) (1)

(2) (4)

Page 56: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD55

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

ORDERING INFORMATION

NOTE: for other seals, consult factory.

Approximate Coil Weight: .47 lbs (.21 kg)

EQ-S4M – – – –

OPTIONS BODIESBuna Standard B0 Up to 8 l/min Blank Without BodyBuna Standard C0 Up to 12 l/min N 3/8” BSP Ports

S #6 SAE Ports

VOLTAGE12 12 VDC24 24 VDC

“PJ” COIL TERMINATIONJH DIN 43650 (Hirschmann)JD Deutsch-Integral DT04-2PJA AMP SupersealJJ AMP Jr. Timer

S4P

S4M Flow (L/min)

Pre

ssu

re D

rop (

bar)

0

4

6

2

6 2 8

8

4 10

Pressure Drop vs. Flow

12

3->4

1->4

2->1

2->3

S1

S2

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Re

gu

late

d F

low

(L

/min

)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

Pressure Drop vs. Flow Oil 26cSt (121 SSU)@ 50°C (122°F)

Pressure Compensation from Inlet to Work Port Oil 26cSt (121 SSU)@ 50°C (122°F)

S4P

S4M Flow (L/min)

Pre

ssu

re D

rop (

bar)

0

4

6

2

6 2 8

8

4 10

Pressure Drop vs. Flow

12

3->4

1->4

2->1

2->3

S1

S2

(for bodies style and sizes see section “Accessories”)

Reg

ulat

ed F

low

(l/m

in)

Differential Pressure (bar)

Flow (l/min)

Pre

ssur

e D

rop

(bar

)

Page 57: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD56

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, Motor Spool, proportional directional valve.

OPERATIONEG-S4M, when de-energized, blocks flow at (2) and allows flow between (1), (3) and (4). When coil (S1) is energized, flow is allowed from (3) to (4), and from (2) to (1). When coil (S2) is energized, flow is allowed from (3) to (2), and from (4) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1EG-S4M 4 WAY 3 POSITION, MOTOR SPOOL, PROPORTIONAL DIRECTIONAL VALVE

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 15 cu-in/min 250 cc/min bar @ 210 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°COperating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 4WCavity Tools Kit(form tool, reamer, tap) 40500002

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-Imposed Dither Frequency 100-200 HzCoil Resistance (12 VDC) 5.6 Ohm ±5% at 68°F (20°C)

COIL SPECIFICATIONS

VALVE SPECIFICATIONSHYDRAULIC SYMBOL

PERFORMANCE

Flow

(l/m

in)

Current (mA)

Flow vs. CurrentCoil 12 VDC - 100 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (122°F)

Operating curves made with circuit having a pressure drop of 14bar

(3) (1)

(2) (4)

Page 58: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD57

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

ORDERING INFORMATION

NOTE: for other seals, consult factory.

Approximate Coil Weight: .47 lbs (.21 kg)

EG-S4M – – – –

OPTIONS BODIESBuna Standard B0 Up to 22 l/min Blank Without Body

N 3/8” BSP PortsS #6 SAE Ports

VOLTAGE12 12 VDC24 24 VDC

“L” COIL TERMINATIONHC DIN 43650 (Hirschmann)DT Deutsch-Integral DT04-2P

S4P

S4M

Pressure Drop vs. Flow

S2

S1

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1

(for bodies style and sizes see section “Accessories”)

Pressure Drop vs. Flow Oil 26cSt (121 SSU) @ 50°C (122°F)

Pressure Compensation from Inlet to Work Port Oil 26cSt (121 SSU) @ 50°C (122°F)

Reg

ulat

ed F

low

(l/m

in)

Differential Pressure (bar)

Flow (l/min)

Pre

ssur

e D

rop

(bar

)

S4P

S4M

Pressure Drop vs. Flow

S2

S1

Hex. 0.95 [24]

Page 59: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD58

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, Cylinder Spool, proportional directional valve.

OPERATIONEQ-S4P, when de-energized, blocks flow to all ports. When coil (S1) is energized, flow is allowed from (3) to (4), and from (2) to (1). When coil (S2) is energized, flow is allowed from (3) to (2), and from (4) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Re

gu

late

d F

low

(L

/min

)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

EQ-S4P 4 WAY 3 POSITION, CYLINDER SPOOL, PROPORTIONAL DIRECTIONAL VALVE

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 10 cu-in/min 160 cc/min bar @ 210 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°COperating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 18 ft-lbs (26 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity POWER 4WCavity Tools Kit(form tool, reamer, tap) 40500029

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1300 mAPWM or Super-Imposed Dither Frequency 100-200 HzCoil Resistance (12 VDC) 6.85 Ohm ±5% at 68°F (20°C)

COIL SPECIFICATIONS

VALVE SPECIFICATIONSHYDRAULIC SYMBOL

PERFORMANCE

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Regula

ted F

low

(L/m

in)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

Flow

(l/m

in)

Current (mA)

Flow vs. CurrentCoil 12VDC – 100 Hz PWM – Oil 26cSt (121 SSU) @ 50°C (122°F)Operating curves made with circuit having a pressure drop of 14bar

(3) (1)

(2) (4)

Page 60: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD59

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

DIMENSIONS

ORDERING INFORMATION

NOTE: for other seals, consult factory.

Approximate Coil Weight: .47 lbs (.21 kg)

EQ-S4P – – – –

OPTIONS BODIESBuna Standard B0 Up to 8 l/min Blank Without BodyBuna Standard C0 Up to 12 l/min N 3/8” BSP Ports

S #6 SAE Ports

VOLTAGE12 12 VDC24 24 VDC

“PJ” COIL TERMINATIONJH DIN 43650 (Hirschmann)JD Deutsch-Integral DT04-2PJA AMP SupersealJJ AMP Jr. Timer

S4P

S4M Flow (L/min)

Pre

ssu

re D

rop (

bar)

0

4

6

2

6 2 8

8

4 10

Pressure Drop vs. Flow

12

3->4

1->4

2->1

2->3

S1

S2

(for bodies style and sizes see section “Accessories”)

Pressure Drop vs. Flow Oil 26cSt (121 SSU)@ 50°C (122°F)

Pressure Compensation from Inlet to Work Port Oil 26cSt (121 SSU)@ 50°C (122°F)

0

8

4

12

Flow vs. Current

16

20

Flo

w (

L/m

in)

From 2 to 1

From 2 to 3

Current (mA)

200 400 600 800 1000 1200

Re

gu

late

d F

low

(L

/min

)

0

6

9

3

15050 200

12

15

100 250

Differential Pressure (bar)

Pressure Com pensation from inlet to work port

Reg

ulat

ed F

low

(l/m

in)

Differential Pressure (bar)

S4P

S4M Flow (L/min)

Pre

ssu

re D

rop (

bar)

0

4

6

2

6 2 8

8

4 10

Pressure Drop vs. Flow

12

3->4

1->4

2->1

2->3

S1

S2

Flow (l/min)

Pre

ssur

e D

rop

(bar

)

Page 61: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD60

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 40 / 2018

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, Cylinder Spool, proportional directional valve.

OPERATIONEG-S4P, when de-energized, blocks flow to all ports. When coil (S1) is energized, flow is allowed from (3) to (4), and from (2) to (1). When coil (S2) is energized, flow is allowed from (3) to (2), and from (4) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to create a pressure compensated flow control function.

FEATURES • Hardened parts for long-life.• Industry common cavity.• Excellent linearity and low hysteresis characteristics.• Cartridges are voltage interchangeable.• Optional coil voltages and terminations available.• Unitized, molded coil design.• Continuous duty rated solenoid.

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1EG-S4P 4 WAY 3 POSITION, CYLINDER SPOOL, PROPORTIONAL DIRECTIONAL VALVE

Flow Range See curves for various versionsMax System Pressure 3500 PSI (241 bar)Leakage 15 cu-in/min 250 cc/min bar @ 210 barHysteresis ±5%Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°COperating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)Cavity DELTA 4WCavity Tools Kit(form tool, reamer, tap) 40500002

Current Supply Characteristics PWM (Pulse Width Modulation)Rated Current Range 400-1400 mAPWM or Super-Imposed Dither Frequency 100-200 HzCoil Resistance (12 VDC) 5.6 Ohm ±5% at 68°F (20°C)

COIL SPECIFICATIONS

VALVE SPECIFICATIONSHYDRAULIC SYMBOL

PERFORMANCE

(3) (1)

(2) (4)

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1Flow

(l/m

in)

Current (mA)

Flow vs. CurrentCoil 12 VDC - 100 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (122°F)

Operating curves made with circuit having a pressure drop of 14bar

Page 62: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD61

PROPORTIONAL CONTROLS

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

0 /

2018

ORDERING INFORMATION

NOTE: for other seals, consult factory.

Approximate Coil Weight: .47 lbs (.21 kg)

EG-S4P – – – –

OPTIONS BODIESBuna Standard B0 Up to 22 l/min Blank Without Body

N 3/8” BSP PortsS #6 SAE Ports

VOLTAGE12 12 VDC24 24 VDC

“L” COIL TERMINATIONHC DIN 43650 (Hirschmann)DT Deutsch-Integral DT04-2P

S4P

S4M

Pressure Drop vs. Flow

S2

S1

Pressure Compensation from inlet to work port

�������������������������

���������������

0 200 600

10

5

15

800

Current (mA)

Flow vs. Current

20

25

Flow

(l/m

in)

30

1200

From 2 to 3

1000600400

From 2 to 1

S4P

S4M

Pressure Drop vs. Flow

S2

S1

Hex. 0.95 [24]

DIMENSIONS

(for bodies style and sizes see section “Accessories”)

Reg

ulat

ed F

low

(l/m

in)

Differential Pressure (bar)

Flow (l/min)

Pre

ssur

e D

rop

(bar

)Pressure Drop vs. Flow

Oil 26cSt (121 SSU) @ 50°C (122°F)

Pressure Compensation from Inlet to Work Port Oil 26cSt (121 SSU) @ 50°C (122°F)

Page 63: PROPORTIONAL CARTRIDGE VALVES - Homepage ......Max Power Consumption 11 Watt (20 C) Coil Termination Deutsch-Integral DT04-2P (DT) AMP Jr. Timer 84-9419 (AJ)

Page PD62

PROPORTIONAL CONTROLSW

40 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.