proposed uxc racks layout for re4 lv system
DESCRIPTION
Proposed UXC Racks layout for RE4 LV System. Hardware Information. Rack space is needed for the following RE4 hardware : Link Board Box(LBB) for RE4 signal cables 3 LBBs per tower. i.e. one per level (X2, X3, X4). MAO and EASY Crate for RE4 Low Voltage Cables 1 MAO/disc 1 EASY Crate/tower. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/1.jpg)
1
Proposed UXC Racks layout for RE4 LV System
ESR Meeting 14 March 2012
![Page 2: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/2.jpg)
2
Hardware Information• Rack space is needed for the following RE4
hardware :– Link Board Box(LBB) for RE4 signal cables• 3 LBBs per tower.
– i.e. one per level (X2, X3, X4).
– MAO and EASY Crate for RE4 Low Voltage Cables• 1 MAO/disc• 1 EASY Crate/tower
ESR Meeting 14 March 2012
-RE4 hardware will be installed in the existing racks in USC and UXC• 18 LV cables in one easy crate
• 72 signal cable in one Link Board Box
![Page 3: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/3.jpg)
3ESR Meeting 14 March 2012
• After RE4 EDR, we had an agreement with CSC Colleagues for the rack distribution of our equipments
• This new layout was verified in UXC55• On the basis of this layout and after a visual inspection of the
cable paths near to the racks length of all the cables has been calculated with a 3-d model of station 3.
• A new layout has been proposed and agreed with CSC colleagues taken in to the account the constraint of a maximum length of 16.5m for the signal cables in order keep the same trigger latency.
• Lengths of the HV and LV cables have been evaluated• Paths and lengths need to be x-checked by the integration
team
![Page 4: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/4.jpg)
Signal Cable RE+4
![Page 5: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/5.jpg)
![Page 6: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/6.jpg)
6ESR Meeting 14 March 2012
X3A51 X4A51
YE+3 FAR
X2A52
![Page 7: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/7.jpg)
7
X3J51 X4J51
YE+3 NEAR
X2J52
![Page 8: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/8.jpg)
Signal cable RE-4
![Page 9: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/9.jpg)
![Page 10: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/10.jpg)
10ESR Meeting 14 March 2012
X2S52 X3S51 X4S51
YE-3 FAR
![Page 11: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/11.jpg)
11ESR Meeting 14 March 2012
X3V51 X4V51
YE-3 NEAR
X2V52
![Page 12: Proposed UXC Racks layout for RE4 LV System](https://reader035.vdocument.in/reader035/viewer/2022062408/56814385550346895db0034d/html5/thumbnails/12.jpg)
12
X2A52 X2S52
If needed Heat Exchanger for LV crates:Power dissipation:Easy crate : 3 x 0.32=0.96 KW LV MAO A3486 AC to DC : 0.45 KWremove Blank panel 1U on the top as in X2S52 and move up all the equipments by one unit(big job)