pt ami hot oil system

Upload: haryonodaniel

Post on 09-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/7/2019 Pt Ami Hot Oil System

    1/6

    PT AMI HOT OIL SYSTEM

    Hot oil are used to dissolve PTA slurry in PTA

    heater (BE-506A/B) and to generate steam 28Kg/cm2.G in OSBL Boiler (AE-102A/B).

  • 8/7/2019 Pt Ami Hot Oil System

    2/6

    Hot Oil Properties :

    Hot oil type : Therminol 66

    Appearance : Clear, pale yellow liquid

    Composition : Modified terphenyl

    Flash Point (ASTM D-92) : 184 C (363 F)

    Fire Point (ASTM D-92) : 212 C (414 F)

    Density at 25 C : 1005 kg/m3 (8.39 lb/gal)

    Normal Boiling Point : 359 C (678 F)

    Optimum Use Range : 0-345 C (30-650 F)

    Hot oil is analyzed by hot oil supplier (Solutia) once times per year

  • 8/7/2019 Pt Ami Hot Oil System

    3/6

    Operations

    Heaters: Proper fluid-heater operation will help ensure

    long life of the fluid. Common heater problems include

    flame impingement, excessive heat flux, controlovershoot, low fluid flow, and interlock malfunctions.

    Piping and pumps: A leak-free system will help to

    ensure safe and reliable operation.

  • 8/7/2019 Pt Ami Hot Oil System

    4/6

    Hot Oil System Control

    There are some hot oil control :

    1. ATIC120B (to control hot oil OSBL furnace

    temperature) shut down setting : 340o

    C2. AFIC104 (to control hot oil minimum flow) flow

    setting 600 m3/hr

  • 8/7/2019 Pt Ami Hot Oil System

    5/6

  • 8/7/2019 Pt Ami Hot Oil System

    6/6