  • 1PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    Established in 1968. Incorporated in 1972. 9 branches through-out.

    1. Jakarta2. Palembang3. Dumai4. Pekanbaru5. Bangka6. Surabaya7. Makassar8. Balikpapan9. Sorong

  • 2PRODUCT & SERVICESPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    DIV.1-CORROSION CONTROL SYSTEM:

    CATHODIC PROTECTION SYSTEM IMPRESSED CURRENT CATHODIC PROTECTION SACRIFICIAL ANODE

    MAGNESIUM ALUMINUM ZINC

    CORROSION MONITORING SYSTEM PROTECTIVE COATING SYSTEM

    FIELD JOINT COATING (RAYCHEM Heat Shrink Sleeve) LIQUID EPOXY COATING (POWERCRETE)

    DIV.2-PRODUCTION FLOW CONTROL SYSTEM

  • 3SERVICES:

    CONSULTANCY DESIGN ENGINEERING SUPERVISIONING COMMISSIONING FIELD SURVEYS - ON & OFF SHORES CONSTRUCTIONS AND INSTALLATIONS FABRICATIONS AND ASSEMBLIES PROJECTS MANAGEMENT TURNKEY/EPC CONTRACTUAL UNDERTAKINGS MAINTENANCE ETC.,.

    PRODUCT & SERVICESPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 4 CALTEX PACIFIC INDONESIA BP AMOCO INDONESIA CONOCO INDONESIA UNOCAL INDONESIA TOTAL E&P INDONESIA VICO INDONESIA TRIPATRA ENGINEERING NIPPON STEEL NISCONI INDONESIA SHELL SEMPEC INDONESIA TECHNIP INDONESIA JR McDERMOTT INDONESIA CNOOC

    PUPUK SRIWIDJAJA PERTAMINA SEMEN TONASA PUPUK KALTIM PUPUK KUJANG PLN PDAM JASA MARGA CITRA INDONESIA KRAKATAU STEEL KOMARITIM BONTANG LNG MOBIL OIL INDONESIA KODECO INDONESIA

    CLIENTSPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 5ICCP SYSTEM:ICCP SYSTEM:

    ADOBTABLE TO CONNECT WITH FOREIGN PIPELINE MORE REASONABLE PRICE FOR LONG/BIG PIPELINE SYSTEM EFFICIENT FOR HIGH SOIL RESISTIVITY EXISTING SOURCE OF ELECTRIC POWER

    TR

    SACRIFICIAL ANODE:LIMITATION OF CURRENT SUPPLY BY QUANTITY OF ANODE

    ICCP:CURRENT SUPPLY DRIVEN BY TRANSFORMER RECTIFIER

    SACRIFICIAL ANODE:SACRIFICIAL ANODE:

    WITHOUT MAINTENANCE

    ICCP vs Sacrificial Anode

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 6CORROSION BASICSsacrificial anode

    cp systems

    Sacrificial Anode (e.g. Aluminium, Magnesium or Zinc)

    Coating defect

    Pipe

    Failed coating-exposed steel

    CP current to pipe coating defectConnection to pipe(return path of current)

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 7Connection to pipe(return path of current)

    CP current to pipe coating defect

    Impressed Current Anodes (e.g. MMO Ti or FeSiCr)

    Pipe

    +-T/R

    Failed coating- exposed steel

    CORROSION BASICSimpressed current

    cp systems

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 8TRANSFORMER RECTIFIER

    @ 5 PcsHigh SiliconChromiumCast IronAnode

    FOREIGN PIPELINE

    NEGATIVE BOND BOXPOSITIVE

    JUNCTION BOX

    DEEP GROUNDBED

    OVERALL=28M

    ICCP SYSTEM (TYPICAL)

    50 mm CableXLPE/PVC

    50 mm CableXLPE/PVC 50 mm Cable

    XLPE/PVC

    PIPELINE WILL BE PROTECTED

    30A48V

    ICCP SYSTEMPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 9 OIL COOLED TRANSFORMER RECTIFIER MMO Ti ANODE 50 MM2 XLPE/PVC POSITIVE & NEGATIVE

    CABLE AND ACESSORIES POSITIVE JUNCTION BOX NEGATIVE JUNCTION/BONDING BOX TEST POINT 10 MM2 XLPE/PVC TEST POINT CABLE

    ICCP MATERIALSPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 10

    ICCP MATERIALS: TRANSFORMER RECTIFIER

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    EEME Transformer RectifierManufacturer

    Built in 0-60 seconds ON/OFF timer, removable copper link to connect portable current interrupterAccessories

    + 0.5%Accuracy

    < 5.0%Ripple Voltage

    KVA2Minimum Power to be

    supplied

    A-DC60DC output current

    V-DC15DC output voltage

    A-AC2AC input current

    Hz50Frequency

    V-AC400AC input voltage, 3 phase, 2 wires

    TR-1TR No.

    Oil NaturalCooling type

    Double winding with separated screenWinding type

    Outdoor, Enclosure IP56Installation area

    IEC 60529Applicable standard

    TRANSFORMER RECTIFIER DATA SHEET

  • 11

    ENCLOSURE CLASS

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 12

    TR: Tap Setting Oil Cooled(Based on Requisition)

    ICCP MATERIALS: TRANSFORMER RECTIFIER

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 13

    TR: Variac, Step-less (ALTERNATIVE)

    ICCP MATERIALS: TRANSFORMER RECTIFIER

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 14

    ICCP MATERIALS: BONDING BOX

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    BONDING BOX USED TO CONNECT WITH:

    > EXISTING PIPE> DISCONTINUOUS PIPE:

    Insulating Joint at LBCV, PigReceiver, Pig Launcer

    > ADDITIONAL PIPE

  • 15

    Cathodic Protection Bonding Box. Enclosure: pre-galvanized sheet steel

    of 1.2 mm thickness. Protection: IP56,

    PJB will install in non-hazardous area, Door sealing: Gasket add on the door and flange plate. Painting: Internal and external epoxy

    powder/polyester RAL7032. Dimension: (H)600xW(400)x(D)200mm. Internal Equipment: One bus copper bar,

    5 M8 studs terminal including spare with crimped lugs c/w 25 A 50 mV shunt and 600 W 3 ohm variable resistor for 5 strings of 1cx50 mm2 XLPE/PVC cable.

    ICCP MATERIALS: BONDING BOX

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 16

    ICCP MATERIALS: DEEPWELL GROUNDBED

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    PJB

    MMO Ti Anode

    To TR

    Carbon Steel Pipe

    Coke Breeze

    PVC Pipe

    Vent Pipe

  • 17

    ICCP TEST POINT (Every 2 KM)

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 18

    CALDWELL INSULATIONPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    ROYSTON HANDYCAP

  • 19

    XLPE INSULATION

    TYPE & DESCRIPTION STANDARD SIZE (mm

    2) APPLICATION

    N 2X Y N A 2X Y 0.6/1 KV

    Single + multicores. Power & control cables XLPE insulated, PVC

    sheathed .

    SPLN 43-6

    1 x 1.5 s/d 500 2 x 1.5 s/d 300

    3 x 1.5 s/d 300 4 x 1.5 s/d 300

    5 x 1.5 s/d 50 7 x s/d 61 x 1.5

    7 x s/d 61 x 2.5 7 x s/d 61 x 4

    7 x s/d 61 x 6

    Indoor and outdoor installation dan underground if used Digunakan untuk instalasi di dalam dan di luar gedung dan didalam tanah jika diberi pelindung cukup.

    N 2X R/F Gb Y N A 2X R/F GbY

    0.6/1 KV Multicores power & control cables, XLPE insulated, galvanised

    steel wire / flat & tape armoured. PVC

    sheathed

    SPLN 43-7

    2 x 1.5 s/d 300 3 x 1.5 s/d 300

    4 x 1.5 s/d 300 5 x 1.5 s/d 50

    7 x s/d 61 x 1.5 7 x s/d 61 x 2.5

    7 x s/d 61 x 4 7 x s/d 61 x 6

    Indoor and outdoor bulling installation and in underground.

    N 2X B Y NA 2X B Y0.6/1 KV

    Multicores power & control cables, XLPE insulated, galvanised steel tape armoured.

    PVC sheathed.

    SPLN 43-8

    1 x 1.5 s/d 500 2 x 1.5 s/d 300

    3 x 1.5 s/d 300 4 x 1.5 s/d 300

    5 x 1.5 s/d 50 7 x s/d 61 x 1.5

    7 x s/d 61 x 2.5 7 x s/d 61 x 4

    7 x s/d 61 x 6

    Indoor and outdoor bulling installation and in underground.

    N 2X C Y NA S 2X C Y

    0.6/1 KV Multicores power & control cables, XLPE

    insulated and sheathed, copper wire and tape

    screened

    SPLN 43-9

    2 x 1.5 s/d 50 2 x 1.5 s/d 300

    3 x 1.5 s/d 300 4 x 1.5 s/d 300

    5 x 1.5 s/d 50 7 x s/d 61 x 1.5

    7 x s/d 61 x 2.5 7 x s/d 61 x 4

    7 x s/d 61 x 6

    Indoor and outdoor bulling installation and in underground.

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 20

    Sacrificial AnodeHigh Potential Magnesium

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    Consendate Line

    Gas Line

    Caldwell insulated with Rosyton Handycap

    Test Point

    Magnesium installationWithout SPICING KIT

    Magnesium Anode

  • 21

    TEST POINTPT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

  • 22

    Sacrificial AnodeHigh Potential Magnesium

    PT. KARTINI UTAMACorrosion and Production Flow Enhancement Control Systems Company

    As normally required, the anode is packaged in a cloth bag with a prepared backfill mixture that works to maintain moisture around the anode and lowers the anode to earth resistance.SAPMAG packaged anodes are shipped on pallets in plastic bags that must be removed prior to installation.

    0.01% max0.50 - 1.3%0.02% max0.05% max0.03% max0.001% max0.05% maxRemainder* Per ASTM B843 Industry Standard for M1C high potential magnesium anodes.

    AluminumManganeseCopperSiliconIronNickelOthers eachMagnesium

    SAPMAG Anode Chemistry*