Put the PRO in Protein Characterization Aaron Boice LC/Q-TOF Product Manager 5-June-2017 For Research Use Only. Not for use in diagnostic procedures.

Upload: doandang

Post on 05-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Put the PRO in Protein Characterization

Aaron Boice LC/Q-TOF Product Manager 5-June-2017

For Research Use Only. Not for use in diagnostic procedures.

Page 2: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 3: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 4: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Page 5: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Protein Characterization Poses Many Questions

Intact Mass?

Relative Glycoforms?

ADC DAR Calculation?

Peptide Sequence Mapping?

Post Translational Modifications?

Disulfide Bonds?

Host Cell Proteins?

Glycan Profile?

For Research Use Only. Not for use in diagnostic procedures.

Page 6: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Multiple Experiments – One Set of Tools

Sample Preparation

Separation

Data Processing Detection

Page 7: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Sample Prep Separation Detection Data Analysis Agilent AssayMAP Bravo

InfinityLab LC Series and

AdvanceBio Columns 6545XT

AdvanceBio LC/Q-TOF MassHunter BioConfirm

For Research Use Only. Not for use in diagnostic procedures.

Agilent BioPharma Workflow Platform for LC/MS

Page 8: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Step 1

For Research Use Only. Not for use in diagnostic procedures.

Agilent AssayMAP Bravo

Sample Prep Separation Detection Analysis

• Graphical Software (no programming language needed!)

• Bravo Liquid Handling Robot • Micro-chromatography tips

Page 9: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Step 2

Sample Prep Separation Detection Analysis

7100 CE

Agilent 1290 Infinity II UHPLC

2D–LC

Agilent AdvanceBio LC Columns

LC/MS compatible columns designed for: • Intact Proteins, Heavy/Light Chains,

Fab/Fc Regions • Peptide Mapping, PTM separations • Glycan Profiling

Page 10: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Sample Preparation

New 6545XT AdvanceBio LC/Q-TOF

S R

S G T

L T F D

Y R V V T S

H V E

K

N A

V

Intact Protein Industry leading data quality and sensitivity at the intact level

Peptide Mapping and PTMs Ready for routine confirmation or digging deeper with IterativeMS/MS

Glycan Profiling Full released glycan workflow with BioConfirm B.09

Sample Prep Separation Detection Analysis

Page 11: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Step 4

Sample Prep Separation Detection Analysis

MassHunter BioConfirm – One Stop Protein Analysis Software

Input

Output

Protein Sequence

Experimental Conditions

• Deconvolved mass confirmation

• Glycoform results • Peptide Sequence

Coverage • Glycan Profile

Page 12: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 13: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact Protein Characterization Workflow

For Research Use Only. Not for use in diagnostic procedures.

Sample Prep Separation Detection Analysis

Intact mAb

HC & LC

Deglycosylated mAb

Deglycosylated HC & LC

ProZyme InstantPC glycan tag or 2-AB tag

F(ab)’2

Fd’ & LC

Fc

Page 14: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agilent 1290 Infinity II Agilent AdvanceBio LC Columns

PLRP-S 1000 Å

AdvanceBio RP mAb

Poroshell 300

Intact Protein Characterization

Sample Prep Separation Detection Analysis

Zorbax SB 300 RRHD

For Research Use Only. Not for use in diagnostic procedures.

Page 15: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact Protein Characterization

Sample Prep Separation Detection Analysis

• Intact protein spectral clarity (10E-8 vacuum)

• Large molecule SWARM autotune

• 30k m/z mass range

• Vent-free capillary removal

• Quick start methods with PLRP-S column

For Research Use Only. Not for use in diagnostic procedures.

Page 16: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact Protein Characterization

Sample Prep Separation Detection Analysis

For Research Use Only. Not for use in diagnostic procedures.

Page 17: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Deconvolved Spectrum

Glycoforms and other PTMs

NEW: Select for Relative Quant

Raw Spectrum

For Research Use Only. Not for use in diagnostic procedures.

Page 18: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact ADC Drug Antibody Ratio (DAR) Calculation

calculated DAR

DAR peak list shows all components and % area for each species

For Research Use Only. Not for use in diagnostic procedures.

Page 19: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Reduced ADC DAR Calculation

heavy chain

light chain

For Research Use Only. Not for use in diagnostic procedures.

Total DAR from both HC and LC

Page 20: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

sample prep

separation detection

data analysis

Page 21: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact Protein Spectral Quality

- 0.64 ppm

1.44 ppm

- 0.06 ppm

0.78 ppm

- 3.72 ppm

G0F + G0F

G0F + G1F

G1F + G1F

G1F + G2F

G2F + G2F

3.54 ppm

(G0F+G0F)

- GlcNAc

(G0F+G1F)

- GlcNAc

(G1F+G1F)

- GlcNAc

(G1F+G2F)

- GlcNAc (G2F+G2F)

- GlcNAc

Sample: 0.5 ug NISTmAb

Chromatography: Agilent PLRP-S 1000 Å, 2.1 × 50 mm, 5 μm, PL1912-1502

5 min H2O/ACN gradient w/0.1% FA @500 μL/min

For Research Use Only. Not for use in diagnostic procedures.

Page 22: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Know More at the Intact Level

1. Schiel et al.; State-of-the-Art and Emerging Technologies for Therapeutic Monoclonal Antibody Characterization Volume 2. ... ACS Symposium Series; American Chemical Society: Washington, DC, 2015.

• In a previously published multi-lab study1 characterizing the NISTmAb, 18 proteoforms are described by three labs using different HRAM systems. Each lab missed some of the proteoforms, while injecting 5 µg or performing an infusion.

For Research Use Only. Not for use in diagnostic procedures.

Page 23: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Know More at the Intact Level

Agilent 6545XT

148363.1

148488.1

148525.2

148623.6

148652.9

148686.6

148846.7

149003.5

Agilent 6545XT

146592.5

146755.8

146918.5

147632.5

147836.0

147998.5

148038.6

148161.9

148200.9

148324.7

• The 6545XT AdvanceBio LC/Q-TOF detects every proteoform described, while injecting less material, and with the best mass accuracy for 13 of the 18 peaks

Missed

2 Labs

2 Labs

2 Labs

2 Labs

1 Lab

Missed

1 Lab

2 Labs

1 Lab

1 Lab

1 Lab

2 Labs

5.0 µg 0.5 µg 5.0 µg 0.5 µg

For Research Use Only. Not for use in diagnostic procedures.

1. Schiel et al.; State-of-the-Art and Emerging Technologies for Therapeutic Monoclonal Antibody Characterization Volume 2. ... ACS Symposium Series; American Chemical Society: Washington, DC, 2015.

Page 24: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Improved Spectral Clarity from Improved TOF Vacuum

1 ug trastuzumab Grey – 6545 LC/Q-TOF Green – 6545XT AdvanceBio LC/Q-TOF

2 x10

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

Counts (%) vs. Deconvoluted Mass (amu)

146800 147000 147200 147400 147600 147800 148000 148200 148400 148600 148800 149000 149200 149400 149600 149800 150000

Narrower peaks

Deeper valley between glycoforms

For Research Use Only. Not for use in diagnostic procedures.

Page 25: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Optimizing for Proteins with Large Molecule SWARM Autotune

4 x10

0

0.25

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

3

3.25

3.5

3.75

4

4.25

4.5

4.75

Counts vs. Mass-to-Charge (m/z)

3050 3060 3070 3080 3090 3100 3110 3120 3130 3140 3150 3160 3170 3180

Same AdvanceBio LC/Q-TOF Blue – Large Molecule SWARM Autotune Red – Standard Mass Range SWARM Autotune

Unprocessed mAb spectra zoomed to show charge states

For Research Use Only. Not for use in diagnostic procedures.

Page 26: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Intact Protein Analysis: Denatured vs. Native MS of NIST mAb

Denaturing Conditions 0.1% Formic Acid in H2O 0.1% Formic Acid in Acetonitrile

Native MS 100 mM Ammonium Acetate, pH 7

For Research Use Only. Not for use in diagnostic procedures.

Page 27: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

NativeMS Posters at ASMS

Thursday 12:00pm – 2:30pm ThP 616 Enhanced Detection of Non-Covalently Bound Enzyme Complexes Using a Dedicated Large Molecule Autotune on a Q-TOF Mass Spectrometer 800 kDa GroEL complex under native conditions

Thursday 10:30am – 1:00pm ThP 603 Higher Order Structure of Intact Proteins by Capillary Electrophoresis Native Ion Mobility Mass Spectrometry CE/MS of proteins under native conditions

For Research Use Only. Not for use in diagnostic procedures.

Page 28: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 29: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Peptide Sequence Mapping and PTM Identification

Sample Prep Separation Detection Analysis

• Preconfigured protocols that required no programming language

• Get reproducible digestion • Run parallel digestions for method development or multiple

enzyme preparations

For Research Use Only. Not for use in diagnostic procedures.

Page 30: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Peptide Sequence Mapping and PTM Identification

Sample Prep Separation Detection Analysis

Agilent 1290 Infinity II

Agilent AdvanceBio LC Columns

AdvanceBio Peptide Mapping Tried and true for routine peptide mapping applications.

NEW – AdvanceBio Peptide Plus The latest AdvanceBio column specifically designed for LC-MS peptide applications. The charged surface provides sharp symmetrical peaks with just formic acid and provide alternate separation for critical PTMs at higher mass loads

For Research Use Only. Not for use in diagnostic procedures.

Page 31: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Peptide Sequence Mapping and PTM Identification

Sample Prep Separation Detection Analysis

• Quick-start peptide mapping method w/columns

• Identification confidence (<1 ppm mass error, 50k resolution)

• One-click optimization with SWARM autotune

• IterativeMS/MS mode

• Agilent Jet Stream ion source

For Research Use Only. Not for use in diagnostic procedures.

Page 32: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Peptide Sequence Mapping and PTM Identification

Sample Prep Separation Detection Analysis

MassHunter BioConfirm 1. Find Peptides

2. Identify Peptides

3. Assign Possible PTMs

4. Confirm Sequence

AUTOMATICALLY

For Research Use Only. Not for use in diagnostic procedures.

Page 33: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Peptides Found

Sequence Map

Annotated MS/MS Spectrum

Red/Yellow/Green Confirmation of Protein Chromatogram

MS Spectrum

For Research Use Only. Not for use in diagnostic procedures.

Page 34: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Peptide Mapping Performance, AdvanceBio LC/Q-TOF

Sample: 250 ng NISTmAb digested with Trypsin and Lys-C on AssayMAP Bravo

Chromatography: Agilent AdvanceBio Peptide Mapping, 2.1 × 150 mm, 2.7 μm (p/n 653750-902)

20 min H2O/ACN gradient w/0.1% FA @400 μL/min

For Research Use Only. Not for use in diagnostic procedures.

99.4% Sequence Coverage single injection, 250 ng protein

Page 35: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Oxidized peptide

Non-oxidized peptide DLTMISR Relative % oxidation = 1.6%

Methionine Oxidation PTM

For Research Use Only. Not for use in diagnostic procedures.

Page 36: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

2x10

0

0.25

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

3

3.25

3.5

3.75

4

4.25

4.5

4.75

5

5.25

5.5

5.75

6

6.25

6.5

6.75

7

7.25

7.5

7.75

8

T74.0604

L,I86.0965

100.8496126.0552

144.0666

171.0775

175.1200

189.0863199.0725

b2217.0827

229.0918

245.1374

y2

262.1507

b3-H2O

312.1557

b3

330.1666

y3

375.2340

409.7209

443.1929

y4

506.2769

575.3696602.3394

y5

619.3600

619.6263

Counts v s. M ass-to-Charge (m/z)

60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660

b4-H2Oy2 -NH3

y1

R

3x10

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

0.6

0.65

0.7

0.75

0.8

0.85

0.9

0.95

1

L,I

86.0960

88.0377

111.0555

144.0642

y1-NH3

158.0920

175.1176

189.0875

b2-H2O

199.0721

b2

217.0824

229.6381

y2

262.1503

286.1798

b3-H2O

312.1563

330.1614

351.6818

y3

375.2351

394.2188

417.2133

426.2170

458.2711

478.2066502.2897

y4

522.2694

571.3618

y5

635.3547

Counts vs. Mass-to-Charge (m/ z)

60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660

DLTMISR

Methionine Oxidation Localization by MS/MS

DLTMISR

y3 y4 y5

Non-oxidized

375.2340

506.2769 619.3600

Oxidized 375.2351 522.2694 635.3547

same +16 +16

AdvanceBio Peptide Plus Column AdvanceBio LC/Q-TOF See more details in App Note: 5991-8046EN

For Research Use Only. Not for use in diagnostic procedures.

y3

y3

y4

y4

y5

y5

Page 37: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Iterative MS/MS – When you need to dig deeper

m/z

Precursors selected for MS/MS

Rolling excluded precursors

m/z

LC/MS Run 1

LC/MS Run 2

Additional Runs …

Wednesday 12:00 – 2:30pm WP-694 Enhanced Analysis of Host Cell Proteins from CHO Cell Cultured mAb Using a Newly Developed Q-TOF Instrument, Linfeng Wu

For Research Use Only. Not for use in diagnostic procedures.

Page 38: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 39: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

AssayMAP Glycan Profiling Preparation

For Research Use Only. Not for use in diagnostic procedures.

Sample Prep Separation Detection Analysis

Intact mAb

HC & LC

Deglycosylated mAb

Deglycosylated HC & LC

ProZyme InstantPC glycan tag or 2-AB glycan tag

F(ab)’2

Fd’ & LC

Fc

Page 40: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

AdvanceBio Glycan Mapping Column

For Research Use Only. Not for use in diagnostic procedures.

Page 41: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

AdvanceBio LC/Q-TOF

For Research Use Only. Not for use in diagnostic procedures.

Adjusts instrument conditions to prevent unwanted fragmentation of labile molecules like glycans

Page 42: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

B.09 Preview of Glycan Profiling

For Research Use Only. Not for use in diagnostic procedures.

Use AM database for formula

match

Optional: choose glycan tag

BioConfirm runs Find By Formula algorithm to find glycan features

Found glycans are reported in

the Biomolecule Table

Page 43: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Agenda

The Right Tools for the Job

Tackling Intact Proteins

Break it Down – Peptides and PTMs

Sweet Success – Released Glycan Profiling

Conclusion

For Research Use Only. Not for use in diagnostic procedures.

Page 44: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Page 45: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

Page 46: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

For Research Use Only. Not for use in diagnostic procedures.

• Tools to address protein characterization at multiple levels

• Efficiency

• Results you can trust

Page 47: Put the PRO in Protein Characterization - Agilent · Put the PRO in Protein Characterization ... • Large molecule SWARM autotune ... 4 4.25 4.5 4.75

Collaborate - Ask and answer questions

Connect - Interact with other Agilent users

Discover - Find relevant discussions, documents, and videos

Share - Contribute your insights

• Enter our $50 Amazon gift card contest:

– Register for the Agilent Community

– Take our 3 question survey:

• community.agilent.com/asms

June 14, 2017 ASMS 51

community.agilent.com

Agilent Community

Agilent Community

community.agilent.com