py installation manual

35
INSTALLATION, OPERATION & MAINTENANCE MANUAL SINGLE PACKAGED ROOF TOP AIR CONDITIONERS PY SERIES MODELS: PY036 - PY360 Part Number: 800-213-64 (Rev.-04)

Upload: ksahisham

Post on 01-Dec-2015

170 views

Category:

Documents


12 download

DESCRIPTION

Zamil PY Packaged

TRANSCRIPT

Page 1: PY Installation Manual

INSTALLATION,OPERATION

&MAINTENANCE

MANUAL

SINGLE PACKAGED ROOF TOP AIR CONDITIONERSPY SERIES

MODELS: PY036 - PY360

Part Number: 800-213-64 (Rev.-04)

Page 2: PY Installation Manual

Contents PageGeneral

Model decoding ...................................................................................................................................................... 2

General statement .................................................................................................................................................. 3

Warranty ................................................................................................................................................................. 3

Safety issues .......................................................................................................................................................... 3

Inspection for damage ............................................................................................................................................ 3

Installation instructionsGeneral ................................................................................................................................................................... 4

Location of unit ....................................................................................................................................................... 4

Service clearance ................................................................................................................................................... 5

Rigging instructions ................................................................................................................................................ 5

Condensate drain connection ................................................................................................................................. 6

Duct connection ...................................................................................................................................................... 6

Electric heater ......................................................................................................................................................... 6

Unit weight & weight distribution ............................................................................................................................. 6

Unit dimensions ................................................................................................................................................... 7-9

Cable size ............................................................................................................................................................. 10

Operation instructionsStart-up inspection & check list ............................................................................................................................ 10

Electrical data .................................................................................................................................................. 11-17

Microprocessor controller, operation & functions .................................................................................................. 18

Electronic thermostat ............................................................................................................................................ 18

Controls and sequence of operation .................................................................................................................... 19

Maintenance instructionsAirflow adjustment ................................................................................................................................................ 20

Crankcase heater ................................................................................................................................................. 20

Cleaning of coils & filters ...................................................................................................................................... 20

Belt tension testing procedure ......................................................................................................................... 20-21

Preventive maintenance schedule ....................................................................................................................... 22

Recommended spare parts list ............................................................................................................................. 23

Trouble shooting chart ..................................................................................................................................... 24-25

Typical schematic wiring diagram .................................................................................................................... 26-31

Parts list ........................................................................................................................................................... 32-34

INDEX

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

1

Page 3: PY Installation Manual

1 &

2B

ASI

C3,

4 &

5N

OM

INA

LC

OO

LIN

GC

APA

CIT

Y(M

BH

)

7B

LOW

ERM

OTO

R

6EL

ECTR

ICA

LSU

PPLY

( V-P

h-H

z )

9H

EATE

R O

PTIO

NS

(kW

/STA

GE)

11C

ON

DEN

SER

CO

IL

PYP

AC

KA

GE

DU

NIT

075

090

100

120

150

180

210

240

300

340

360

R :

1.5

HP

OD

PZ

:2

HP

OD

P

Z:

2 H

P O

DP

E:

3 H

P O

DP

E:

3 H

P O

DP

E:

3 H

P O

DP

G:

5 H

P O

DP

G:

5 H

P O

DP

J:

7.5

HP

OD

P

J:

7.5

HP

OD

P

J:

7.5

HP

OD

PL

:10

HP

OD

P

L:

10 H

P O

DP

M:

15 H

P O

DP

N:

NO

HE

ATE

R

B:

6/1

C:

7.5/

1

D:

10/2

E:

12/2

F:

15/2

G:

20/2

(For

PY0

90 -

150)

H:

25/2

(For

PY0

90 -

150)

J:A

LUM

INU

M F

IN

K:C

OA

TED

ALU

MIN

UM

FIN

L:C

OP

PE

R F

IN

M:A

LUM

INU

MFI

NS

WIT

H T

G.

N:C

OP

PE

R F

INS

WIT

H T

G.

8D

RIV

E O

PTIO

NS

10EV

APO

RAT

OR

CO

IL

J:A

LUM

INU

M F

IN

K:C

OA

TED

ALU

MIN

UM

FIN

L:C

OP

PE

R F

IN

M:A

LUM

INU

MFI

NS

WIT

H T

G.

N:C

OP

PE

R F

INS

WIT

H T

G.

MO

DEL

S: P

Y075

- PY

360

(BEL

T D

RIV

EN M

OTO

R)

1 &

2B

ASI

C3,

4 &

5N

OM

INA

LC

OO

LIN

GC

APA

CIT

Y(M

BH

)

7B

LOW

ERM

OTO

R

6EL

ECTR

ICA

LSU

PPLY

( V-P

h-H

z )

9H

EATE

R O

PTIO

NS

(kW

/STA

GE)

11C

ON

DEN

SER

CO

IL

PYP

AC

KA

GE

DU

NIT

036

048

060

U :

0.5

HP

OD

P(D

IREC

T D

RIV

E)

W :

0.75

HP

OD

P(D

IREC

T D

RIV

E)

C:2

08/2

30-1

-60*

H:2

08/2

30-3

-60

M:3

80-3

-60

(

4 W

IRE

)

F :4

60-3

-60

N:

NO

HE

ATE

R

A:

5/1

C:

7.5

/1

D:

10 /2

**

J:A

LUM

INU

M F

IN

K:C

OA

TED

ALU

MIN

UM

FIN

L:C

OP

PE

R F

IN

M:A

LUM

INU

MFI

NS

WIT

H T

G.

N:C

OP

PE

R F

INS

WIT

H T

G.

8D

RIV

E O

PTIO

NS

N :

DIR

EC

TD

RIV

E

10EV

APO

RAT

OR

CO

IL

J:A

LUM

INU

M F

IN

K:C

OA

TED

ALU

MIN

UM

FIN

L:C

OP

PE

R F

IN

M:A

LUM

INU

MFI

NS

WIT

H T

G.

N:C

OP

PE

R F

INS

WIT

H T

G.

12A

CC

ESSO

RIE

S

N :

STA

ND

AR

D U

NIT

MO

DEL

S: P

Y036

- PY

060

(DIR

ECT

DR

IVE

MO

TOR

)M

OD

EL D

ECO

DIN

G

N:

NO

HE

ATE

R

F:

15/2

G:

20/2

H:

25/2

J:

30/2

K:

35/2

L:

40/2

(For

PY2

40 -

360)

H:2

08/2

30-3

-60

M:3

80-3

-60

(

4 W

IRE

)

F :4

60-3

-60

J : A

LT. I

K :

ALT

. II

13EL

ECTR

ICA

LO

PTIO

NS

N:

STD

. UN

ITI

: AN

TI-IC

EU

:U

VM

V:

VOLT

FR

EEC

ON

TAC

TS*

K:

ADJ.

PRES

SUR

ESW

ITC

HA

:I &

UB

:I &

VC

:U

& V

D:

I, U

& V

E:

I, U

& K

F:

I, V

& K

G:

U, V

& K

H:

I, U

, V &

KJ

:I &

KL

:V

& K

M:

U &

K

13EL

ECTR

ICA

LO

PTIO

NS

15TH

ERM

OST

ATO

PTIO

N

S:U

NIT

WIT

HTH

ER

MO

STA

T

D:U

NIT

WIT

HO

UT

THE

RM

OS

TAT

14FI

LTER

OPT

ION

S

N:

STD

. UN

ITI

: AN

TI-IC

EU

:U

VM

V:

VOLT

FR

EEC

ON

TAC

TS**

*K

:AD

J. P

RES

SUR

ESW

ITC

HA

:I &

UB

:I &

VC

:U

& V

D:

I, U

& V

E:

I, U

& K

F:

I, V

& K

G:

U, V

& K

H:

I, U

, V &

KJ

:I &

KL

:V

& K

M:

U &

K

NO

TE:

*–

App

licab

le fo

r PY

036

& P

Y04

8 m

odel

s on

ly.

**–

App

licab

le fo

r PY

060

mod

els

only

.

***

–V

olt f

ree

cont

act o

ptio

n is

ava

ilabl

e as

: A) U

nit O

N/T

RIP

indi

catio

n, B

) Com

pres

sor R

UN

/TR

IP in

dica

tion,

C) B

low

er m

otor

RU

N/T

RIP

indi

catio

n.

A:1

" TH

ICK

ALU

MIN

UM

NO

TE: *

Vol

t fre

e co

ntac

t opt

ion

is a

vaila

ble

as: A

) Uni

t ON

/TR

IP in

dica

tion,

B) C

ompr

esso

r RU

N/T

RIP

indi

catio

n, C

) Blo

wer

mot

or R

UN

/TR

IP in

dica

tion.

16TH

ERM

OST

ATO

PTIO

N

S:U

NIT

WIT

HTH

ERM

OST

AT

D:U

NIT

WIT

HO

UT

THER

MO

STAT

15FI

LTER

OPT

ION

S

A:1

" TH

ICK

ALU

MIN

UM

B:2

" TH

ICK

ALU

MIN

UM

12PD

S O

PTIO

N

N :

NO

PD

S

P : S

TD. U

NIT

WIT

H P

DS

14A

CC

ESSO

RIE

S

N :

STA

ND

AR

D U

NIT

C :

STD

. UN

IT W

ITH

FRE

SH

AIR

HO

OD

& M

AN

UA

LD

AM

PE

R

A : E

CO

NO

MIZ

ER

B :

EC

ON

OM

IZE

RW

ITH

EN

THA

LPY

SE

NS

OR

2

Page 4: PY Installation Manual

GENERALGENERAL STATEMENTThis unit is from the PY series that was designed & built for the optimum performance. However, it is required that you become wellacquainted with good practices for the proper installation/operation/and maintenance procedures in order to ensure a safe trouble freeoperation, year after year.

Please read through the whole manual contents before you attempt to install/operate/ and maintain the unit.

Most of the procedures described in this manual require certain skills and experience. The installation and other maintenance proceduresshould be performed only by highly skilled and experienced technicians. The end user’s role should be limited to the cleaning of thefilter.

Please consult your nearest “Zamil” representative for further information.

The PY units can be supplied, depending on the End User requirement, as the basic “Cool Only” version, or the “Heat & Cool” version(with electric heater module).

WARRANTYAll of the PY series of Packaged Roof Top Units are covered by the standard warranty terms against any manufacturer defect. Shouldyou encounter any problem that falls under the warranty terms please contact your nearest “Zamil” representative.

3

SAFETY ISSUESThere are three degrees of safety hazards that are identified throughout this manual as WARNING (where the situation will result inpersonal injury), CAUTION (where personal injury might occur), and ATTENTION (where minor personal injury and/or property dam-age could happen). Please understand and respect those identifications.

WARNING: The PY units operate on a high voltage with moving parts (at high speed) which can lead to serious injuries and/or damage to the unit. Never attempt to service the unit unless the main electrical power supply has been disconnected.

CAUTION: Extra care should be observed when installing, test running, adjusting, servicing, or maintaining the unit as thehazard of explosion, fire, electrical shock, and potential personal injury and property damage are present.

When performing any task pertaining to the installation and maintenance of the unit, the skilled technician should observe all theapplicable safety measures (wear of safety helmet, boots, gloves, and goggles. Use of proper handling materials for brazing and useof wet cloth for quenching. A fire extinguisher should be easily accessible etc.). He should also read all the instructions and informationin this Manual prior to attempting to perform any installation or servicing of the unit.

All applicable local codes should also be observed.

INSPECTION FOR DAMAGEThe unit should be carefully inspected visually for any sign of physical damage due to mishandling. Whenever a damage is detected,please indicate it on the corresponding delivery note before you sign it and inform your nearest “Zamil” office.

Page 5: PY Installation Manual

GENERALThese units are shipped completely assembled, charged, and wired. They do not require any field installation of refrigerant tubing.Units require external power, thermostat wiring, condensate drain piping and ducting as applicable.

Size of unit for an installation should be based on a heat gain calculation made according to applicable standards. Units must also beinstalled in accordance with regulations of the "National Fire Protection Association" and local electrical codes. Where local regulationsconflicts with the instructions in this manual, installer should adhere to local standards.

Prepare your concrete pad or steel stand based on the corresponding dimensions. Remove shipping protective covers and woodencrating and lift unit from base and place in position with suitable vibration isolators.

All field installed accessories are to be installed by the customer.

LOCATION OF UNITWhen selecting the location for the unit, the following points should be kept in mind:

1. Provisions for a concrete pad or steel stand base.

2. That the terrain allows for drainage away from the unit.

3. If the unit is to be roof mounted, inspect the roof for load bearing capacity. The roof should have sufficient structural strength to carrythe weight of the unit.

4. Install unit on vibration isolation pads, i.e. on rubber mounting pads.

5. Availability of electric power.

6. To position the unit for unrestricted air circulation of the condenser air inlet and to prevent any possibility of air recirculation from thecondenser fan discharge air (see figure on next page).

7. Check minimum clearances required for your unit, with regard to walls, or other obstructions (see figure on next page).

8. Air cooled equipment should not be installed under low structural overhangs which can cause condenser air recirculation or restric-tion. Observe minimum of clearance (see figure on next page).

9. Care should be taken to prevent air from other sources from entering condenser, if this air is at a high temperature.

10. Level the unit on its final location and be sure that the levelling tolerance is ±5 mm per linear meter in any direction.

CAUTION: Do not install the unit as indoor unit, install it in an open area, and unit air inlets must not be located near exhaustvents or other source of contaminated air.

INSTALLATION INSTRUCTIONS

4

Page 6: PY Installation Manual

SERVICE CLEARANCE

MODEL DIMENSIONSNUMBER A B C D E

PY036 85 105 105 150 90PY048 85 105 105 150 90PY060 85 105 105 150 90PY075 90 105 105 200 90PY090 90 105 105 200 90PY100 90 105 105 200 90PY120 90 105 105 200 90PY150 90 105 105 200 90

NOTE: All dimensions are in cm.

A : Clearance dimension from condenser coilB : Clearance dimension from electrical control box, blower & motor/evaporator access panelC : Clearance dimension from condenser coilD : Clearance dimension over the condenser fanE : Clearance dimension from filter access panel

MODEL DIMENSIONSNUMBER A B C D E

PY180 120 90 115 250 120PY210 120 90 115 250 120PY240 120 90 115 250 120PY300 120 90 115 250 120PY340 120 90 115 250 120PY360 120 90 115 250 120

A : Clearance dimension from condenser coil & compressor access panelB : Clearance dimension from filter access panelC : Clearance dimension from electrical control box, blower & motor/evaporator access panelD : Clearance dimension over the condenser fanE : Clearance dimension from condenser coil

MODELS: PY036 - PY150 MODELS: PY180 - PY360

ATTENTION TO RIGGERS• Insert 2" nominal pipe through holes in the base rail as shown in the figure below for slings.• Holes in base rail are centered around the unit center of gravity.• Use wooden pallet or spreader bar when rigging, to prevent the slings from damaging the unit.• Rollers may be used to move the unit on the roof or ground.

CAUTION: All panels should be in place when rigging.

RIGGING INSTRUCTIONS

5

A

B

D

ACCESS PANEL FOR CONTROL BOX,

CONDENSER AIR INLET

COMPRESSOR & BLOWER MOTORD

ACCESS PANEL FOR

B

EVAPORATOR COIL

SPREADER BAR

MUST BE 2" NOMINAL PIPE THRU UNIT FOR SLINGS TO AVOID BASE DAMAGE

END

PROPER CLEARANCE TO BE PROVIDED

COMPRESSOR

LIFT LIFT

MODELS: PY036 - PY360

Page 7: PY Installation Manual

CONDENSATE DRAIN CONNECTION• Use standard PVC pipe with NPT connection for the condensate drain. Provide a 'P' trap immediately at the condensate drain connection.• Piping has to be sloped away from the unit.• Remember to remove the drain hole plug before operating the unit. Avoid bends & elbows.

DUCT CONNECTIONThe units can be connected to the ducting in horizontal configuration. Connect ducting using flexible duct connection. The duct shouldbe properly designed and the drive package should match the required CFM & corresponding external static pressure.

ATTENTION: Avoid abrupt changes in size and/or direction of duct to ensure proper unit performance.

UNIT WEIGHT & WEIGHT DISTRIBUTIONMODEL

NUMBERWEIGHTS (Kg.)

K G L NPY036

PY048

PY060

PY075

PY090

PY100

PY120

PY150

PY180

PY210

PY240

PY300

PY340

PY360

195

213

215

335

360

440

445

450

800

840

970

975

1030

1323

45

48

49

83

86

101

102

103

104

106

120

120

124

138

52

58

58

86

93

116

118

119

166

176

200

201

223

200

38

41

42

71

74

95

95

97

98

99

116

116

118

128

-

-

-

-

-

-

-

-

145

151

177

177

179

150

TOTALWEIGHT

(Kg.) M H-

-

-

-

-

-

-

-

132

138

167

169

171

165

K H G

L M N

CONDENSER SECTION

SUPPLY AIR RETURN AIR

R

Y

ELECTRIC HEATERSElectric heater kit is installed as an externally mounted kit at the supply air opening.

60

66

66

95

107

128

130

131

155

170

190

192

215

220

-

-

-

-

-

-

-

-

-

-

-

-

-

164

R Y-

-

-

-

-

-

-

-

-

-

-

-

-

158

6

Page 8: PY Installation Manual

7

UNIT DIMENSIONSPY036 - PY060

NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).

24 [0.94]

Page 9: PY Installation Manual

8

UNIT DIMENSIONSPY075 - PY150

A B C D E F G H J K L M N O P

PY075 - PY090 2080(81.89) 1162(45.75) 1034(40.71) 1114(43.86) 308(12.15) 550(21.64) 798(31.4) 300(11.81) 251(9.87) 396(15.59) 152(5.98) 175(6.88) 24(0.94) 171(6.73) 1775(69.88)

PY100 - PY150 2212(87.1) 1408(55.43) 1085(42.72) 1372(54) 255(10.03) 707(27.84) 790(31.1) 367(14.46) 190(7.48) 476(18.74) 150(5.91) 145(5.71) 48(1.89) 200(7.87) 1907(75.08)

MODELDIMENSIONS

NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).

TOP VIEW

FRONT VIEWSIDE VIEW

POWER SUPPLY CONN

A

P

C

D

BL

F GO

E

132

[5.21

]

NJK H

M

CONDENSER COIL

CONDENSER COIL

AIR OUT

AIR IN

AIR IN

CONDENSER COIL

CONTROL COMPARTMENT

COMPRESSOR / CONTROLSACCESS PANEL

SIDE VIEW

SUPPLY AIR OPENING

RETURN AIR OPENING

Ø 12.7 ( 0.5) MOUNTING HOLES(2 EACH SIDE)

DRAIN OUTLET

ACCESSPANEL

FILTER

SUPPLY AIR RETURN AIR

FRESH AIR OPENING/HOOD(OPTIONAL)

FOR BLOWER & MOTORACCESS PANEL

CONDENSATE DRAIN OUTLET3/4" NPT

Page 10: PY Installation Manual

9

CONTROL COMPARTMENT

ACCESS PANELFOR BLOWER & MOTOR

SUPPLY AIR

SUPPLY AIROPENING

TOP VIEW

FRONT VIEW

COMPRESSOR ACCESS PANEL

SIDE VIEW

AIR OUT

AIR IN

ACCESS PANELCONTROLS

SIDE VIEW

RETURN AIR OPENING

FILT

ER A

CCES

S PA

NEL

(OPTIONAL)FRESH AIR OPENING/HOOD

RETURN AIR

3/4" NPTCONDENSATE DRAIN OUTLET

CONTROL BOXACCESS PANEL

POWER INLET

DRAIN OUTLET

[5.67

]14

4233

[9.17

]

16 x 25mmMOUNTING SLOT (3EACH SIDE)MOUNTING SLOT (4EACH SIDE FOR PY360)

A\IR IN

CONDENSER COIL

A\IR IN

CONDENSER COIL

CONDENSER COIL

G

POWER INLET

K

A

D

B

XL

F

C

R

B

DX G

HU N

SM

UNIT DIMENSIONSPY180 - PY360

MODELA B C D F G H K L N R S M U X

PY180 - PY210 2794(110) 1778(70) 1266(49.83)1715(67.52) 1737(68.37) 197(7.75) 817(32.17) 720(28.35) 1200(47.25) 83(3.27) 912(35.9) 666(26.22) 194(7.64) 171(6.73) -

PY240 - PY340 3048(120) 2135(84.1) 1446(56.94) 2075(81.7) 2152(84.72) 324(12.76) 915(36.02) 740(29.13) 1200(47.25) 84(3.31) 1050(41.34) 666(26.22) 289(11.38) 194(7.64) -

PY360 3683(145) 2184(86) 1446(56.94)2125(83.66) 2184(86) 42(1.65) 938(36.93) 527(20.75) - 97(3.83) 1000(39.37) 680(26.77) 254(10) 372(14.65) 1125(44.29)

DIMENSIONS

NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).

Page 11: PY Installation Manual

POWERSUPPLY

208/230-3-60

OPERATION INSTRUCTIONSSTART-UP INSPECTION & CHECK LISTAfter the installation is completed in all respect, the following points should be covered before the system is switched on for operation.1. Check unit location as per installation instructions.2. Make sure all electrical fasteners/connections are tight and clean.3. All controls are set according to manufacturer's instructions (low & high pressure switch, pump down solenoid, etc...)4. Make sure all valves are open (compressor suction & discharge service valves, liquid line, etc.).5. Follow all the instructions from the warning tags and stickers.6. Check if condenser & blower fan are free to turn without wobbling.7. Remove straps & wooden pieces that holds the compressor in place during transportation.8. Compressor crankcase heater should be energized for 24 hours (special attention should be taken to disable compressor contactor

before energizing the unit.9. Expansion valve bulb is strapped properly at correct location (applicable for PY075 - PY360 only).10. Circuit breaker/fused disconnect switch.11. Blower fan belt is properly tightened and pulleys are properly aligned (applicable for PY075 - PY360 only).12. All refrigerant service valve caps are installed.13. All piping, piping insulation and piping supports are properly installed.14. Thermostat is the right one and installed properly.15. Connect the manifold gauge to suction & discharge line service valves. Prepare recommended instruments for checking Voltage,

Amps, RPM, CFM, static pressure, etc.16. Start the blower fan and condenser fan. Check the amperage against the nameplate ampere.17. Start the compressor & observe the compressor discharge and suction pressures. If not within system design limits, determine

why & take corrective action.

CABLE SIZE• All wiring should be in accordance with local standards.• Before making any connection, check the electric power supply, it must have the same characteristics as what is displayed in the nameplate.• For selecting cable size, refer to wire ampacity table at different MCA (Minimum Circuit Amps) provided in unit electrical data, which

is listed as a guideline (see table below).• Wiring connection to the unit must have suitable insulation of a minimum temperature of 600C.

MODELNo.

PY036 18.9 14 2.5PY048 27 10 6PY060 31.5 10 6PY075 35 8 10PY090 42.1 8 10PY100 48.6 6 16PY120 56.7 4 25PY150 63.1 4 25PY180 93.1 2 35PY210 103.6 2 35PY240 125.7 1/0 53.4PY300 141.3 2/0 67.4PY340 143.5 2/0 67.4PY360 175.6 3/0 85

MCA CONDUCTOR SIZE

AWG METRICMM2

POWERSUPPLY

380-3-60

MODELNo.

MCA CONDUCTOR SIZE

AWG METRICMM2

POWERSUPPLY

460-3-60

MODELNo.

MCA CONDUCTOR SIZE

AWG METRICMM2

PY036 11.1 14 2.5PY048 17.3 14 2.5PY060 20 14 2.5PY075 19.9 14 2.5PY090 25.3 10 6PY100 25.3 10 6PY120 30.2 10 6PY150 34.2 8 10PY180 50.4 6 16PY210 59.4 6 16PY240 72.4 4 25PY300 76.1 4 25PY340 95.7 2 35PY360 116.3 1 52.4

PY036 8.5 14 2.5PY048 13.8 14 2.5PY060 16.5 14 2.5PY075 17.3 14 2.5PY090 19.2 14 2.5PY100 24.4 12 4PY120 29.3 10 6PY150 30.7 10 6PY180 46.3 8 10PY210 52.7 6 16PY240 58.8 6 16PY300 61.7 4 25PY340 75.2 4 25PY360 86.5 3 26.7

POWERSUPPLY

MODELNo.

PY036 25 10 6PY048 37.8 8 10

MCA CONDUCTOR SIZE

AWG METRICMM2

208/230-1-60

Notes: 1. Customer is to select cable size also with cross reference as per cable manufacturer data for voltage reduction per unitlength. The above cable ampacity table is for guidance only.

2. The selected cables for specified units is as per following characteristics:a. Unit without electric heaters.b. Any extra electrical accessories shall add to MCA rate, for more information, refer to unit electrical tables in the catalog.

LEGEND: MCA - Minimum Circuit Amps

(4 WIRE)

10

Page 12: PY Installation Manual

11

MIN. MAX. FLA RLA LRA HP FLA kW FLA

– – 25 40

5 21.7 29.4 40208/230-1-60 187 253 2.3 16.7 84 0.5 1.8

7.5 32.6 43 45

10* 43.5 56.6 60

– – 18.9 30

5 12.6 18.9 30208/230-3-60 187 253 2.3 11.8 67 0.5 1.8

7.5 18.8 25.8 30

10* 25.1 33.6 35

– – 11.1 15

5 7.6 11.8 15380-3-60 342 418 2.3 5.6 39 0.5 1.8

7.5 11.4 16.5 20

10* 15.2 21.3 25

– – 8.5 15

5 6.3 8.9 15460-3-60 414 506 0.9 5.4 29.2 0.5 0.83

7.5 9.4 12.8 15

10* 12.6 16.8 20

POWERSUPPLY(V-Ph-Hz)

VOLTAGERANGE

BLOWERMOTOR

ELECTRICHEATER MCA MOCP

ELECTRICAL DATAMODEL No.: PY036

(4 WIRE)

FM COMPRES-SOR

MIN. MAX. FLA RLA LRA HP FLA kW FLA

– – 37.8 60

5 21.7 37.8 60208/230-1-60 187 253 2.3 24.6 132 0.75 4.7

7.5 32.6 46.6 60

10* 43.5 60.3 70

– – 27 40

5 12.6 27 40208/230-3-60 187 253 2.3 16 97 0.75 4.7

7.5 18.8 29.4 40

10* 25.1 37.3 40

– – 17.3 25

5 7.6 17.3 25380-3-60 342 418 2.3 8.2 50 0.75 4.7

7.5 11.4 20.1 25

10* 15.2 24.9 25

– – 13.8 20

5 6.3 13.8 20460-3-60 414 506 0.9 8.2 50 0.75 2.6

7.5 9.4 15 20

10* 12.6 19 20

POWERSUPPLY(V-Ph-Hz)

VOLTAGERANGE

BLOWERMOTOR

ELECTRICHEATER MCA MOCP

MODEL No.: PY048

(4 WIRE)

FM COMPRES-SOR

MIN. MAX. FLA RLA LRA HP FLA kW FLA

– – 31.5 50

5 12.6 31.5 50208/230-3-60 187 253 2.3 19.6 105 0.75 4.7

7.5 18.8 31.5 50

10* 25.1 37.3 50

– – 20 30

5 7.6 20 30380-3-60 342 418 2.3 10.4 55 0.75 4.7

7.5 11.4 20.1 30

10* 15.2 24.9 30

– – 16.5 25

5 6.3 16.5 25460-3-60 414 506 0.9 10.4 55 0.75 2.6

7.5 9.4 16.5 25

10* 12.6 19 25

POWERSUPPLY(V-Ph-Hz)

VOLTAGERANGE

BLOWERMOTOR

ELECTRICHEATER

MCA MOCP

MODEL No.: PY060

(4 WIRE)

FM COMPRES-SOR

LEGEND:

FM - Fan Motor

HP - Horse Power

FLA - Full Load Amps

RLA - Rated Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

* Combination of 2 heater modules

Page 13: PY Installation Manual

12

187 253 2.5

342 418 2.5

414 506 1.3

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA FLA

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWER SUPPLY(V-Ph-Hz)

PY075 PY090

MODEL NUMBERDESCRIPTION

80

50

42

ELECTRICAL DATAMODELS: PY075 & PY090

1.5(STD)

2(ALT.)

5.6

6.6

2(STD)

3(ALT.)

6.6

8.8

1.5(STD)

2(ALT.)

3.4

4

1.5(STD)

2(ALT.)

2.8

3.5

2(STD)

3(ALT.)

4

5.14

2(STD)

3(ALT.)

3.5

4.1

156

72

74

20.7

10.7

10

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

– – 39.9 50

5/6 12.6/15.1 39.9/39.9 50/50

7.5/10 18.8/25.1 39.9/39.9 50/50

10*/12* 25.1/30.1 39.9/45.9 50/50

15*/20* 37.7/50.2 55.4/71 60/80

25*/30* 62.8/75.3 86.8/102.4 90/110

– – 42.1 50

5/6 12.6/15.1 42.1/42.1 50/50

7.5/10 18.8/25.1 42.1/42.4 50/50

10*/12* 25.1/30.1 42.4/48.6 50/50

15*/20* 37.7/50.2 58.1/73.8 60/80

25*/30* 62.8/75.3 89.5/105.1 100/110

– – 24.2 30

5/6 7.6/9.1 24.2/24.2 30/30

7.5/10 11.4/15.2 24.2/24.2 30/30

10*/12* 15.2/18.2 24.2/27.8 30/30

15*/20* 22.8/30.4 33.5/43 35/45

25*/30* 38/45.6 52.5/62 60/70

– – 25.3 30

5/6 7.6/9.1 25.3/25.3 30/30

7.5/10 11.4/15.2 25.3/25.4 30/30

10*/12* 15.2/18.2 25.4/29.2 30/30

15*/20* 22.8/30.4 34.9/44.4 40/45

25*/30* 38/45.6 53.9/63.4 60/70

– – 18.6 20

5/6 6.3/7.5 18.6/18.6 20/20

7.5/10 9.4/12.6 18.6/20.1 20/25

10*/12* 12.6/15.1 20.1/23.3 25/25

15*/20* 18.8/25.1 27.9/35.8 30/40

25*/30* 31.4/37.7 43.6/51.5 45/60

– – 19.2 25

5/6 6.3/7.5 19.2/19.2 25/25

7.5/10 9.4/12.6 19.2/20.9 25/25

10*/12* 12.6/15.1 20.9/24 25/25

15*/20* 18.8/25.1 28.6/36.5 30/40

25*/30* 31.4/37.7 44.4/52.3 45/60

FM

HP - Horse Power

FM - Fan Motor (Condenser)

BM - Blower Motor

FLA - Full Load Amps

RLA - Rated Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

13.1

8.2

5.9

(3.8 FORPY090)

(1.7 FORPY090)

(1.8 FORPY090)

– – 34 50

5/6 12.6/15.1 34/34 50/50

7.5/10 18.8/25.1 34/38.4 50/50

10*/12* 25.1/30.1 38.4/44.6 50/50

15* 37.7 54.1 60

– – 35 50

5/6 12.6/15.1 35/35 50/50

7.5/10 18.8/25.1 35/39.6 50/50

10*/12* 25.1/30.1 39.6/45.9 50/50

15* 37.7 55.4 60

– – 19.3 25

5/6 7.6/9.1 19.3/19.3 25/25

7.5/10 11.4/15.2 19.3/23.3 25/25

10*/12* 15.2/18.2 23.3/27 25/30

15* 22.8 32.8 35

– – 19.9 30

5/6 7.6/9.1 19.9/19.9 30/30

7.5/10 11.4/15.2 19.9/24 30/30

10*/12* 15.2/18.2 24/27.8 30/30

15* 22.8 33.5 35

– – 16.6 25

5/6 6.3/7.5 16.6/16.6 25/25

7.5/10 9.4/12.6 16.6/19.3 25/25

10*/12* 12.6/15.1 19.3/22.4 25/25

15* 18.8 27 30

– – 17.3 25

5/6 6.3/7.5 17.3/17.3 25/25

7.5/10 9.4/12.6 17.3/20.1 25/25

10*/12* 12.6/15.1 20.1/23.3 25/25

15* 18.8 27.9 30

Page 14: PY Installation Manual

13

187 253 3.8

342 418 1.7

414 506 1.8

– – 46.4 60

5/6 12.6/15.1 46.4/46.4 60/60

7.5/10 18.8/25.1 46.4/46.4 60/60

10*/12* 25.1/30.1 46.4/46.4 60/60

15*/20* 37.7/50.2 55.4/71 60/80

25*/30* 62.8/75.3 86.8/102.4 90/110

– – 48.6 60

5/6 12.6/15.1 48.6/48.6 60/60

7.5/10 18.8/25.1 48.6/48.6 60/60

10*/12* 25.1/30.1 48.6/48.6 60/60

15*/20* 37.7/50.2 58.1/73.8 60/80

25*/30* 62.8/75.3 89.5/105.1 100/110

– – 24.2 30

5/6 7.6/9.1 24.2/24.2 30/30

7.5/10 11.4/15.2 24.2/24.2 30/30

10*/12* 15.2/18.2 24.2/27.8 30/30

15*/20* 22.8/30.4 33.5/43 35/45

25*/30* 38/45.6 52.5/62 60/70

– – 25.3 30

5/6 7.6/9.1 25.3/25.3 30/30

7.5/10 11.4/15.2 25.3/25.4 30/30

10*/12* 15.2/18.2 25.4/29.2 30/30

15*/20* 22.8/30.4 34.9/44.4 40/45

25*/30* 38/45.6 53.9/63.4 60/70

– – 23.8 30

5/6 6.3/7.5 23.8/23.8 30/30

7.5/10 9.4/12.6 23.8/23.8 30/30

10*/12* 12.6/15.1 23.8/23.8 30/30

15*/20* 18.8/25.1 27.9/35.8 30/40

25*/30* 31.4/37.7 43.6/51.5 45/60

– – 24.4 30

5/6 6.3/7.5 24.4/24.4 30/30

7.5/10 9.4/12.6 24.4/24.4 30/30

10*/12* 12.6/15.1 24.4/24.4 30/30

15*/20* 18.8/25.1 28.6/36.5 30/40

25*/30* 31.4/37.7 44.4/52.3 45/60

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWER SUPPLY(V-Ph-Hz)

PY100 PY120

MODEL NUMBERDESCRIPTION

105

55

55

ELECTRICAL DATAMODELS: PY100 & PY120

2(STD)

3(ALT.)

6.6

8.8

3(STD)

8.8

2(STD)

3(ALT.)

4

5.14

2(STD)

3(ALT.)

3.5

4.1

3(STD)

5.14

3(STD)

4.1

97

50

50

16

8.2

8.2

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

– – 56.7 70

5/6 12.6/15.1 56.7/56.7 70/70

7.5/10 18.8/25.1 56.7/56.7 70/70

10*/12* 25.1/30.1 56.7/56.7 70/70

15*/20* 37.7/50.2 58.1/73.8 70/80

25*/30* 62.8/75.3 89.5/105.1 100/110

– – 30.2 40

5/6 7.6/9.1 30.2/30.2 40/40

7.5/10 11.4/15.2 30.2/30.2 40/40

10*/12* 15.2/18.2 30.2/30.2 40/40

15*/20* 22.8/30.4 34.9/44.4 40/45

25*/30* 38/45.6 53.9/63.4 60/70

– – 29.3 35

5/6 6.3/7.5 29.3/29.3 35/35

7.5/10 9.4/12.6 29.3/29.3 35/35

10*/12* 12.6/15.1 29.3/29.3 35/35

15*/20* 18.8/25.1 29.3/36.5 35/40

25*/30* 31.4/37.7 44.4/52.3 45/60

HP - Horse Power

FM - Fan Motor (Condenser)

BM - Blower Motor

FLA - Full Load Amps

RLA - Rated Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

19.6

10.4

10.4

FM

Page 15: PY Installation Manual

14

187 253 3.8

342 418 1.7

414 506 1.8

– – 59.2 70

5/6 12.6/15.1 59.2/59.2 70/70

7.5/10 18.8/25.1 59.2/59.2 70/70

10*/12* 25.1/30.1 59.2/59.2 70/70

15*/20* 37.7/50.2 59.2/73.8 70/80

25*/30* 62.8/75.3 89.5/105.1 100/110

– – 63.1 80

5/6 12.6/15.1 63.1/63.1 80/80

7.5/10 18.8/25.1 63.1/63.1 80/80

10*/12* 25.1/30.1 63.1/63.1 80/80

15*/20* 37.7/50.2 63.1/78.6 80/80

25*/30* 62.8/75.3 94.4/110 100/125

– – 30.9 40

5/6 7.6/9.1 30.9/30.9 40/40

7.5/10 11.4/15.2 30.9/30.9 40/40

10*/12* 15.2/18.2 30.9/30.9 40/40

15*/20* 22.8/30.4 34.9/44.4 40/45

25*/30* 38/45.6 53.9/63.4 60/70

– – 34.2 40

5/6 7.6/9.1 34.2/34.2 40/40

7.5/10 11.4/15.2 34.2/34.2 40/40

10*/12* 15.2/18.2 34.2/34.2 40/40

15*/20* 22.8/30.4 39/48.5 40/50

25*/30* 38/45.6 58/67.5 60/70

– – 28.4 35

5/6 6.3/7.5 28.4/28.4 35/35

7.5/10 9.4/12.6 28.4/28.4 35/35

10*/12* 12.6/15.1 28.4/28.4 35/35

15*/20* 18.8/25.1 28.6/36.5 35/40

25*/30* 31.4/37.7 44.4/52.3 45/60

– – 30.7 40

5/6 6.3/7.5 30.7/30.7 40/40

7.5/10 9.4/12.6 30.7/30.7 40/40

10*/12* 12.6/15.1 30.7/30.7 40/40

15*/20* 18.8/25.1 31.5/39.4 40/40

25*/30* 31.4/37.7 47.3/55.1 50/60

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWER SUPPLY(V-Ph-Hz)

PY150 PY180

MODEL NUMBERDESCRIPTION

195&

164

123&

100

95&

101

ELECTRICAL DATAMODELS: PY150 & PY180

3(STD)

5(ALT.)

8.8

12.7

5(STD)

7.5(ALT.)

12.7

20.4

3(STD)

5(ALT.)

5.14

8.4

3(STD)

5(ALT.)

4.1

6.4

5(STD)

7.5(ALT.)

8.4

14.1

5(STD)

7.5(ALT.)

6.4

10.2

156

72

74

20.7

10.7

10

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

– – 85.4 110

10*/12* 25.1/30.1 85.4/85.4 110/110

15*/20* 37.7/50.2 85.4/85.4 110/110

25*/30* 62.8/75.3 94.4/110 110/110

– – 93.1 125

10*/12* 25.1/30.1 93.1/93.1 125/125

15*/20* 37.7/50.2 93.1/93.1 125/125

25*/30* 62.8/75.3 104/119.6 125/125

– – 44.7 60

10*/12* 15.2/18.2 44.7/44.7 60/60

15*/20* 22.8/30.4 44.7/48.5 60/60

25*/30* 38/45.6 58/67.5 60/70

– – 50.4 60

10*/12* 15.2/18.2 50.4/50.4 60/60

15*/20* 22.8/30.4 50.4/55.6 60/60

25*/30* 38/45.6 65.1/74.6 70/80

– – 42.5 50

10*/12* 12.6/15.1 42.5/42.5 50/50

15*/20* 18.8/25.1 42.5/42.5 50/50

25*/30* 31.4/37.7 47.3/55.1 50/60

– – 46.3 60

10*/12* 12.6/15.1 46.3/46.3 60/60

15*/20* 18.8/25.1 46.3/46.3 60/60

25*/30* 31.4/37.7 52/59.9 60/60

HP - Horse Power

FM - Fan Motor (Condenser)

BM - Blower Motor

FLA - Full Load Amps

RLA - Rated Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

32.1&25

16.7&12

16.4&12

FM(each)

(1 for PY150 &2 for PY180)

Page 16: PY Installation Manual

15

187 253 3.8

342 418 1.7

414 506 1.8

– – 95.9 125

10*/12* 25.1/30.1 95.9/95.9 125/125

15*/20* 37.7/50.2 95.9/95.9 125/125

25*/30* 62.8/75.3 95.9/110 125/125

– – 103.6 125

10*/12* 25.1/30.1 103.6/103.6 125/125

15*/20* 37.7/50.2 103.6/103.6 125/125

25*/30* 62.8/75.3 104/119.6 125/125

– – 53.7 70

10*/12* 15.2/18.2 53.7/53.7 70/70

15*/20* 22.8/30.4 53.7/53.7 70/70

25*/30* 38/45.6 58/67.5 70/70

– – 59.4 70

10*/12* 15.2/18.2 59.4/59.4 70/70

15*/20* 22.8/30.4 59.4/59.4 70/70

25*/30* 38/45.6 65.1/74.6 70/80

– – 48.9 60

10*/12* 12.6/15.1 48.9/48.9 60/60

15*/20* 18.8/25.1 48.9/48.9 60/60

25*/30* 31.4/37.7 48.9/55.1 60/60

– – 52.7 70

10*/12* 12.6/15.1 52.7/52.7 70/70

15*/20* 18.8/25.1 52.7/52.7 70/70

25*/30* 31.4/37.7 52.7/59.9 70/70

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWER SUPPLY(V-Ph-Hz)

PY210 PY240

MODEL NUMBERDESCRIPTION

239

145

125

ELECTRICAL DATAMODELS: PY210 & PY240

5(STD)

7.5(ALT.)

12.7

20.4

7.5(STD)

20.4

5(STD)

7.5(ALT.)

8.4

14.1

5(STD)

7.5(ALT.)

6.4

10.2

7.5(STD)

14.1

7.5(STD)

10.2

225

140

114

33.6

18.6

17.3

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

– – 125.7 150

10*/12* 25.1/30.1 125.7/125.7 150/150

15*/20* 37.7/50.2 125.7/125.7 150/150

25*/30* 62.8/75.3 125.7/125.7 150/150

35*/40* 87.9/100.4 135.4/151 150/175

– – 72.4 90

10*/12* 15.2/18.2 72.4/72.4 90/90

15*/20* 22.8/30.4 72.4/72.4 90/90

25*/30* 38/45.6 72.4/74.6 90/90

35*/40* 53.2/60.8 84.1/93.6 90/100

– – 58.8 70

10*/12* 12.6/15.1 58.8/58.8 70/70

15*/20* 18.8/25.1 58.8/58.8 70/70

25*/30* 31.4/37.7 58.8/59.9 70/70

35*/40* 43.9/50.2 67.6/75.5 70/80

FM(each)

HP - Horse Power

FM - Fan Motor (Condenser)

BM - Blower Motor

FLA - Full Load Amps

RLA - Rated Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

42

23.5

19.2

(5.4 FORPY240)

(2.7 FORPY240)

(2.7 FORPY240)

Page 17: PY Installation Manual

16

187 253 5.4

342 418 2.7

414 506 2.7

– – 137.2 175

10*/12* 25.1/30.1 137.2/137.2 175/175

15*/20* 37.7/50.2 137.2/137.2 175/175

25*/30* 62.8/75.3 137.2/137.2 175/175

35*/40* 87.9/100.4 137.2/151 175/175

– – 141.3 175

10*/12* 25.1/30.1 141.3/141.3 175/175

15*/20* 37.7/50.2 141.3/141.3 175/175

25*/30* 62.8/75.3 141.3/141.3 175/175

35*/40* 87.9/100.4 141.3/156.1 175/175

– – 74.4 90

10*/12* 15.2/18.2 74.4/74.4 90/90

15*/20* 22.8/30.4 74.4/74.4 90/90

25*/30* 38/45.6 74.4/74.6 90/90

35*/40* 53.2/60.8 84.1/93.6 90/100

– – 76.1 100

10*/12* 15.2/18.2 76.1/76.1 100/100

15*/20* 22.8/30.4 76.1/76.1 100/100

25*/30* 38/45.6 76.1/76.8 100/100

35*/40* 53.2/60.8 86.3/95.8 100/100

– – 59.7 70

10*/12* 12.6/15.1 59.7/59.7 70/70

15*/20* 18.8/25.1 59.7/59.7 70/70

25*/30* 31.4/37.7 59.7/59.9 70/70

35*/40* 43.9/50.2 67.6/75.5 70/80

– – 61.7 80

10*/12* 12.6/15.1 61.7/61.7 80/80

15*/20* 18.8/25.1 61.7/61.7 80/80

25*/30* 31.4/37.7 61.7/62.4 80/80

35*/40* 43.9/50.2 70.1/78 80/80

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWERSUPPLY(V-Ph-Hz)

PY300 PY340

MODEL NUMBERDESCRIPTION

300

139

150

ELECTRICAL DATAMODELS: PY300 & PY340

7.5(STD)

10(ALT.)

20.4

24.5

7.5(STD

10(ALT.)

20.4

24.5

7.5(STD)

10(ALT.)

14.1

15.8

7.5(STD)

10(ALT.)

10.2

12.2

7.5(STD)

10(ALT.)

14.1

15.8

7.5(STD)

10(ALT.)

10.2

12.2

245

145

125

47.1

24.4

19.6

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

– – 151.8 200

10*/12* 25.1/30.1 151.8/151.8 200/200

15*/20* 37.7/50.2 151.8/151.8 200/200

25*/30* 62.8/75.3 151.8/151.8 200/200

35*/40* 87.9/100.4 151.8/151.8 200/200

– – 155.9 200

10*/12* 25.1/30.1 155.9/155.9 200/200

15*/20* 37.7/50.2 155.9/155.9 200/200

25*/30* 62.8/75.3 155.9/155.9 200/200

35*/40* 87.9/100.4 155.9/156.1 200/200

– – 83.9 110

10*/12* 15.2/18.2 83.9/83.9 110/110

15*/20* 22.8/30.4 83.9/83.9 110/110

25*/30* 38/45.6 83.9/83.9 110/110

35*/40* 53.2/60.8 84/94 110/110

– – 85.6 110

10*/12* 15.2/18.2 85.6/85.6 110/110

15*/20* 22.8/30.4 85.6/85.6 110/110

25*/30* 38/45.6 85.6/85.6 110/110

35*/40* 53.2/60.8 86.3/95.8 110/110

– – 71.9 90

10*/12* 12.6/15.1 71.9/71.9 90/90

15*/20* 18.8/25.1 71.9/71.9 90/90

25*/30* 31.4/37.7 71.9/71.9 90/90

35*/40* 43.9/50.2 71.9/75.5 90/90

– – 73.9 90

10*/12* 12.6/15.1 73.9/73.9 90/90

15*/20* 18.8/25.1 73.9/73.9 90/90

25*/30* 31.4/37.7 73.9/73.9 90/90

35*/40* 43.9/50.2 73.9/78 90/90

FM(each)

HP - Horse Power

BM - Blower Motor

FM - Fan Motor (Condenser)

RLA - Rated Load Amps

FLA - Full Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

53.6

28.6

25

Page 18: PY Installation Manual

17

187 253 5.4

342 418 2.7

414 506 2.7

– – 167.2 220

10*/12* 25.1/30.1 167.2/167.2 220/220

15*/20* 37.7/50.2 167.2/167.2 220/220

25*/30* 62.8/75.3 167.2/167.2 220/220

35*/40* 87.9/100.4 167.2/167.2 220/220

– – 179.7 230

10*/12* 25.1/30.1 179.7/179.7 230/230

15*/20* 37.7/50.2 179.7/179.7 230/230

25*/30* 62.8/75.3 179.7/179.7 230/230

35*/40* 87.9/100.4 179.7/179.7 230/230

– – 101.6 130

10*/12* 15.2/18.2 101.6/101.6 130/130

15*/20* 22.8/30.4 101.6/101.6 130/130

25*/30* 38/45.6 101.6/101.6 130/130

35*/40* 53.2/60.8 101.6/101.6 130/130

– – 108.9 140

10*/12* 15.2/18.2 108.9/108.9 140/140

15*/20* 22.8/30.4 108.9/108.9 140/140

25*/30* 38/45.6 108.9/108.9 140/140

35*/40* 53.2/60.8 108.9/108.9 140/140

– – 82 100

10*/12* 12.6/15.1 82/82 100/100

15*/20* 18.8/25.1 82/82 100/100

25*/30* 31.4/37.7 82/82 100/100

35*/40* 43.9/50.2 82/82 100/100

– – 88.3 110

10*/12* 12.6/15.1 88.3/88.3 110/110

15*/20* 18.8/25.1 88.3/88.3 110/110

25*/30* 31.4/37.7 88.3/88.3 110/110

35*/40* 43.9/50.2 88.3/88.3 110/110

MOCPMCAELECTRICHEATERBM

COMPR-ESSOR(each)

RLA LRA HP FLA Nom. kW FLA

VOLTAGERANGE

FLAMax.Min.

POWERSUPPLY(V-Ph-Hz)

PY360

MODEL NUMBERDESCRIPTION

ELECTRICAL DATAMODEL: PY360

10(STD)

15(ALT.)

24.5

37

10(STD)

15(ALT.)

15.8

23.1

10(STD)

15(ALT.)

12.2

18.5

340

196

173

58.6

35.7

28.6

208/230-3-60

380-3-60 (4 WIRE)

460-3-60

FM(each)

HP - Horse Power

BM - Blower Motor

FM - Fan Motor (Condenser)

RLA - Rated Load Amps

FLA - Full Load Amps

LRA - Locked Rotor Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater modules

LEGEND:

Page 19: PY Installation Manual

MICROPROCESSOR CONTROLLERThese Packaged units are provided with a microprocessor control board incorporating the following features:

• BALANCE LOADING OF COMPRESSORS: The unit’s electronic control automatically operates lead/lag se-quence of compressors. This is to load the compressors evenly over long periods of operation. If required however,compressor-1 can also be set to always lead. In this case, compressor-1 always starts first and stops last.(Selectable through dip switch setting on control board).

• PUMP DOWN FUNCTION: In units equipped with pump down system, the controller provides the time delaybetween solenoid’s opening and compressor starting to equalize the pressure in the system necessary for com-pressor to start-up. (Selectable through dip switch setting on control board).

• COMPRESSOR ANTI-RECYCLING PROTECTION: The controller has a built-in 3 minutes minimum off timer forcompressor. This is for compressor protection in case of accidental manual re-set or immediate re-cycling ofthermostat due to load demand.

• COMPRESSOR LOCK-OUT FUNCTION: If any of the unit’s safety control trips due to abnormal conditions, theelectronic controls locks out the compressor after a pre-determined timing preventing a re-start unless attended bya qualified service technician. The unit can be re-started through thermostat re-set after ensuring safe systemconditions.

• FAULT DIAGNOSTICS: In case of system fault, LED’s on the board emits a flashing signal indicating where thefault is. This is to guide the service technician in identifying the fault.

• DIGITAL I/O’s: The unit’s control board is compatible to operate with a DDC controller or any standard 24V a.c.thermostat commercially available.

• SEQUENTIAL CONTROL: With input signals from the thermostat, the motors in the equipment is started insequential order: supply fan – condenser fan – compressor; at a pre-determined timings.

ELECTRONIC THERMOSTAT

18

General information: Electronic thermostat shall control one or two stage heating and cooling applications. Thethermostat normally displays room temperature and mode of operation.The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows youto select continuous fan operation, or have the fan on intermittent operation with the equipment.The thermostat is best located about 1500 mm (5 Ft.) above floor level, on a partition wall (not an outside wall), and shouldnot be exposed to direct light from lamps, sun etc. It should be in return air stream, away from supply air registers/diffusers.

• Single/dual stage - Cooling & heating.

• Low voltage control - 24 VAC (nominal).

• Room temperature display - in 0C or 0F.

• Mode of operation - FAN/COOL/HEAT/AUTO.

• Fan mode - ON: Continuous fan operation; AUTO: Fan operates ON/OFF with compressor.

• Heating & cooling setpoint is permissible.

• Temperature set button - Up for increasing & down for decreasing temperature.

• Built-in compressor fault & clogged filter indication led lights.

• Remote sensing function as an option. Duct sensor is provided with the thermostat.

800-652-61 1 & 2 1 & 2 OFF-HEAT/COOL ON - AUTO

TYPICAL THERMOSTAT

Part No. HeatingStages

CoolingStages

Selector Switch Positions

Mode Switch Fan Switch

Page 20: PY Installation Manual

19

Scroll compressors are designed to operate in single direction only. Hence, care has to be taken to ensure correct rotationwhen the system is operated. Verification of correct rotation is by observing that the suction pressure drops and dischargepressure rises when compressor run. Reverse rotation results in abnormal sound, as well as, substantially low current drawand by interchanging power supply wire L1 & L3 will correct this problem.The operation of the air conditioning unit is controlled by a 24VAC electronic control board.

GENERALThe thermostat normally displays room temperature and mode of operation. The five buttons on the front of the unit allowcomplete control of the thermostat. The thermostat also allows to select continuous fan operation (useful when using an aircleaner) or have the fan come on with the compressor.

SWITCH FUNCTION- On/Off Key : Switch the system On or Off.- Up Key : To increases the set temperature.- Down Key : To decreases the set temperature.- Mode Key : Changes the mode to Fan, Cool, Heat or Auto.- Fan Key : Changes the Fan Operation to Auto or Continuous.- °C/°F selection : By pressing Mode & UP key together, toggles between °C to °F or vice versa.

USER CONTROLSMode:Select the desired mode of operation by pressing of the mode button:

Fan: In this mode of operation, the compressor will be in inactive state. Display shows room temperature. Fan will be running.

Cool: In this mode of operation, the compressor will be ON after a delay depending on the differential of room tempera-ture & Set temperature.

Heat: In this mode of operation, Fan is ON.

Auto: In auto mode, thermostat provide automatic changeover from heating to cooling mode & vice versa. Thermostatautomatically switches to maintain the desired temperature.

DIP SWITCH OPTIONS AND FUNCTIONSThere are 4 small DIP (Dual in line package) switches on the back of the circuit board which must be configured by theinstaller.

SUPPLY FAN CONTROLSTG1 COOLING

STG1 HEATERSTG2 HEATER

STG2 COOLING

W2

RCG

W1Y2Y1

LVTB

THERMOSTAT

Y2W1Y1

G

24V(R)24V(C)

W2

REMOTESENSOR

FAULT 1FAULT 2

SENSOR

OPTIONAL CONNECTION :IF REMOTE TEMPERATURE SENSINGFUNCTION IS REQUIRED.

NOTE:

(ZAC P/N 80065261)

ATBCOMPRESSOR FAULT SIGNAL (VOLT-FREE CONTACT)

COMP 1

COMP 2(COMMON)

24V ac

( OPTIONAL CONNECTION )

HOOK-UP WIRING DIAGRAM

PACU CONTROL PANEL

LEGEND:ATBLVTB

AUXILIARY TERMINAL BLOCKLOW VOLTAGE TERMINAL BLOCK

( THERMOSTAT CONTROLLER TO PACKAGED UNIT )

CONTROLS & SEQUENCE OF OPERATION

SWITCH ON OFF

1 N. A. -

2 N. A. -

3 N. A. -

4 INDOOR SENSOR REMOTE SENSOR

DIP SWITCH SELECTION

Note:Keep DIP SWITCH 1, 2 & 3 in OFFposition only.

Page 21: PY Installation Manual

MAINTENANCE INSTRUCTIONSAIRFLOW ADJUSTMENT (Applicable for PY075 - PY360 only)The airflow could be adjusted by adjusting pulleys of blower motor or belt tension with proper mounting and alignment of the pulleys:

• Refer to fan performance tables in the catalog for selecting applicable airflow, RPM and brake horse power at specified staticpressure.

• Select the appropriate drive as per motor and blower characteristic in the catalog.

• The set screw shall be loosened to make the pulley moving.

• Adjust pulley’s diameter, opening counter clockwise to reduce RPM and further reduce airflow, while closing clockwise increasesRPM and airflow.

• Tighten the set screw and then install the belts.

• Test the unit operating airflow for further adjustment.

CRANKCASE HEATER• Periodic checking for proper operation or crankcase heater is highly recommended as follows:

a) Check continuity of the heater using multimeter device.

b) Check grounding of the heater by Meggar device (to prevent electrical hazards).

c) Observe whether the heater is warming down the compressor near the oil sump.

CLEANING OF COILS & FILTERS• Turn off the power supply.

• Take out access panel of evaporator coil.

• Remove the filter from its access panel.

• Protect electrical components and motors from water washing.

• Clean the coil by flushing water by pressure washer followed by compressed air from supply to return direction.

• Filter shall be cleaned every six month, in some hygienic application it is recommended for replacement.

• Cleaning drain pan and trap is recommended once in a year to prevent bacteria growing under the coil.

BELT TENSION TESTING PROCEDURE INSTRUCTION (Applicable for PY075 - PY360 only)To determine the lbs. force required to tension a drive, you simply do the following:

1. Measure the Belt span as shown.

2. Divide belt span by 64 to get belt deflection needed to check tension.

3. Set large "0" ring on span scale at required belt deflection. This scale is in 1/16" increments.

4. Set small "0" ring at zero on the "Force Scale" (plunger).

5. Place the larger end of the tension checker squarely on one belt at the center of the belt span. Apply force on the plunger until thebottom of the large "0" ring is even with the top of the next belt or with the bottom of a straight edge laid across the sheaves.

6. Read the force scale under the small "0" ring to determine force required to give the needed deflection.

7. Compare the force scale reading with the correct value for the belt style and cross section used, as given in table on next page.The force should be between the minimum and maximum values shown.

8. If there is too little deflection force, the belts should be tightened. If there is too much deflection force, the belts should beloosened.

Note: Tension new drives at the maximum deflection force recommended. Check the tension at least two times during the first day'soperation as there normally will be a rapid decrease in belt tension until belts have run in. Check the tension periodically after the firstday's operation and keep tension in recommended area. The correct operating tension for a V-belt drive is the lowest tension at whichthe belts will not slip under the peak load conditions. Shafts must be adequate for the tensions required.

20

Page 22: PY Installation Manual

BELT TENSION TESTING PROCEDURE

BELT TENSION CHECKER MEASURE THE BELT DEFLECTION FORCE

BELT TYPE

A

B

BELT CROSS SECTION

3 L

4 L

5 L

SMALL PULLEY PITCH DIA. (P.D.)RANGE

1.25 – 1.752 – 2.252.5 – 3

2.1 – 2.83 – 3.53.7 – 53 – 4.2

4.5 – 5.2

MINIMUM1/25/83/4

1-1/81-1/21-7/8

22-3/8

MAXIMUM5/87/8

1-1/81-5/82-1/82-5/82-7/83-3/8

BELTSDEFLECTION FORCE - LBS.

21

FORCE SCALE

SPAN SCALE

RING"0"

LARGE

"0"RING

SMALL

BELT SPAN

DEFLECTION = 64BELT SPAN

Page 23: PY Installation Manual

PREVENTIVE MAINTENANCE SCHEDULE

12

X

X

X

X

X

X

X

X

X

X

X

X

X

FREQUENCY OF MAINTENANCE, MONTHS(FIRST 4 YEARS)I T E M

CAUTION: Disconnect power supply and allow all rotating parts to stop before servicing the unit.

6

X

X

Clean air filter (Aluminum)*

Pressure wash condenser & cooling coil as required

Check blower belt, tension, wear tear/replace if required

Check alignment of pulleys

Clean drain pan, drain pipe

Clean blower wheel

Check for loose bolts/screws & tighten as necessary

Check all electrical controls, components, wiring terminals, etc..., for sparks,over heat, loose connections/repair or correct

Check for rusted/paint

Check all temperature, pressure readings as applicable and satisfy theoperation performance

Run test all motors and check the amperage

Grease/oil as required

Check vibration isolators

Clean and fix thermal bulbs in the correct location. Insulate it.

Check canvass connections, insulation damage

NOTE: Always observe for abnormal noise or vibration.

MAINTENANCE TOOLS/EQUIPMENT REQUIREDSTANDARD : Screw drivers (Slot & Phillips), adjustable wrenches, pliers, refrigeration wrenches & socket set wrenches, pulley

puller, etc.

SPECIAL : Manifold gauge set, R-22 charging cylinder, belt tension checker, leak detector, vacuum pump with electronic gauges,thermometer, hook type ammeter/voltmeter/ohmmeter and oxy-acetylene brazing set etc.

* If fiberglass filters used, replace it yearly.

22

Page 24: PY Installation Manual

23

PERCENTAGE OF SPARE PARTS

ONE YEAR SUPPLY TWO YEAR SUPPLY

100 UNITS 1000 UNITS 100 UNITS 1000 UNITS

ITEM

Compressor 2% 1% 3% 2%

Capacitor 3 2 5 4

Condenser fan motor 2 1 3 2

Evaporator blower motor 1 0.5 2 1

Belt/Pulley 3 2 6 4

Contactor compressor 2 1 3 2

Heater contactor 2 1 3 2

Contactor fan motors 2 1 3 2

HPS/LPS/other controls 2 1 3 2

Expansion valve 1 0.5 2 1

Filter drier 2 1 3 2

Electric heater 1 0.5 2 1

Fuse link, heater 3 1 4 3

Transformer (24V secondary) 1 0.5 2 1

Propeller fan 1 0.5 2 1

Blower wheel 0.5 0.25 1 0.5

Bearing-blower 2 1 4 2

Thermostat 1 1 2 1

Crankcase heater 3 1 4 2

Filter 2 1 4 4

RECOMMENDED SPARE PARTS

NOTE: When ordering spare parts, please quote the complete model number on the unit nameplate.

Page 25: PY Installation Manual

1. Check the power. Switch ON the circuit breaker.Replace fuse if it blown.

2. Check wiring against diagram.3. Check and correct it.4. Replace it.

1. Replace battery

1. Correct belt. Check tension and alignment.2. Check wiring against diagram.3. Check and correct it.4. Replace if.5. Replace it.

1. Check the rotation of blower, interchange phaseof blower motor from blower motor contactor.

1. Adjust it & check belt tension.2. Adjust the pitch of the pulley.3. Check and remove the obstructions.4. Verify static pressure and fan performance data.5. Change pulley (if blower motor ampere within rated load).6. Check all dampers opened properly. Balance air.7. Clean it.8. Clean it.

1. Adjust the pitch of the pulley.2. Select suitable combination.3. Check the duct design.

1. Re-set the unit and determine the reason. Checkhigh & low pressure (refer to symptom for "low/high suction pressure & high discharge pressure").

2. Replace it.3. Check and replace it.4. Replace it.

1. a) Verify the reason for low suction pressure(refer to symptom for "low suction pressure").

b) Verify the reason for high discharge pressure(refer to symptom for "high discharge pressure").

c) Check dome temperature. RLA each phase.Verify the reason.

2. Check and relocate as required.3. Lower the temperature setting to 210C for test.1. a) Verify the reason & correct it (refer to symptom

for "low suction pressure").b) Verify the reason for high discharge pressure.

(refer to symptom for "high discharge pressure").c) Check comp. RLA against nameplate for each phase,

check comp. dome temperature, etc. & correct it.1. Check for gas leak & charge freon as required.2. Adjust it. Check belt tension.3. Adjust the pulley.4. Clean it.5. Clean it.6. Check return air grille sizes, etc. against design.7. Verify and correct it.8. Check and correct/replace it.

1. Verify and adjust it.2. Adjust air quantity.3. Check & verify. Isolate the area to be cooled & observe.4. Check design/unit selection.5. Check superheat & adjust it, if required.6. Check and replace compressor.

1. Fan blade stuck with ventury. Check & correct it.2. Check freon and adjust it, if necessary.3. Clean it.4. Verify the reason and correct it.5. Check and replace it.6. Check and replace it.

1. Power off/Blown fuse

2. Faulty field wiring3. Loose connections4. Defective thermostat

1. Battery life is over

1. Blower belt slipped/not fixed2. Faulty wiring3. Burned wiring4. Defective blower motor contactor5. Defective blower motor

1. Wrong rotation (Applicable initial start up/or aftera power failure), 3 phase motor

1. Loose Belt2. Variable pulley wide open3. Return air obstructed4. High static pressure5. Improper pulley selection6. Closed dampers/improper air balance7. Dirty filter8. Dirty cooling coil

1. Variable pulley needs more tightening2. Improper pulley/motor selection3. Low external static pressure

1. Safety circuit open due to low suction pressure,high discharge pressure, overload protector

2. Defective compressor contactor3. Burned wiring4. Defective compressor

1. Safety circuit open due to:a) Low suction pressureb) High discharge pressures

c) Overload protector

2. Thermostat in cold location3. High thermostat setting

1. Safety circuit open due to:a) Low pressure switchb) High pressure switchc) Overload protector

1. Less Freon2. Loose belt3. Variable pulley widely open4. Dirty filter5. Dirty cooling coil6. Return air restricted7. Improper expansion valve bulb installation/location8. Restriction in expansion valve/filter dryer

1. Excess freon charge2. Excess air quantity3. High room temperature condition4. Undersize unit (serving large area)5. Expansion valve widely open6. Defective compressor valve

1. Condenser fan motor not working properly2. Excess freon charge3. Dirty condenser4. High ambient condition/Air in condenser obstructed5. Defective fan motor capacitor6. Defective fan motor

Thermostat shows no display

Thermostat LCD panel display is notbright & does not function properlyBlower not running, compressor shortcycles

Blower running, no sufficient air

Blower running, but with not enoughsupply air

Blower running and delivers excessair

Blower runs, compressor not working

Compressor runs, but short cycling

Thermostat shows faulty indication

Low suction pressure

High suction pressure

High discharge pressure

TROUBLE SHOOTING CHART SYMPTOM CAUSES CHECK & CORRECTIVE MEASURE

24

Page 26: PY Installation Manual

TROUBLE SHOOTING CHART SYMPTOM CAUSES CHECK & CORRECTIVE MEASURE

1. Low suction pressure

2. High discharge pressure

3. Less air quantity4. Cooling coil ices up

5. Second stage (If exists) not working

6. Serving large area1. Low ambient condition2. Safety low pressure switch open due to low

suction pressure3. Fan cycling (whenever applicable) setting low4. Thermostat setting too low5. Cooling coil ices-up

6. Less air quantity

1. High discharge pressure

2. High thermostat setting3. Serving large area4. Less air quantity

5. High ambient condition6. Dirty condenser1. Less freon2. Less air quantity

3. Dirty filter4. Dirty cooling coil

1. Safety circuit open due to low pressure switch

1. Thermostat in cold location

1. Imbalance freon2. Malfunctioning pumpdown solenoid valve

1. Leaky pumpdown solenoid valve

1. Improper installation2. Improper vibration isolators3. Loose parts or mountings4. Tubing rattle5. Bent fan blade causes vibration

6. Defective bearings7. Belt tension is high8. Blower motor pulley is not aligned1. Improper installation2. Improper vibration isolators3. Abnormal noise in the unit4. Unit too close to the slab/wall openings5. Duct design (high static)6. Wooden packing beneath the compressor is not removed1. Low voltage2. Single phase failure3. Burned wirings4. Overload protector open5. Defective contactor6. Burned compressor motor winding7. Damaged (stuck) compressor1. Burned wirings2. Grounded wirings3. Faulty field wiring4. Grounded compressor/blower motor5. Undersize circuit breaker

1. Verify the reason & correct it (refer to symptomfor "low suction pressure").

2. Verify the reason and adjust the freon, if required.(referto symptom for "high discharge pressure").

3. Refer to symptom for "blower works, less air".4. Determine the reason (refer to symptom for

"cooling coil ice up") & correct it.5. Set the thermostat to lower temperature (210C)/

or verify the reason.6. Check the design.1. Check and verify the ambient temperature.2. Check the reason and correct it (refer to

symptom for "low suction pressure").3. Adjust the fan cycling.4. Adjust the thermostat setting.5. Verify the reason and correct it (refer to

symptom for "cooling coil ice up").6. Verify the reason and correct it (refer to

symptom for "blower works, less air").

1. Check and verify the reason (refer to symptomfor "high discharge pressure").

2. Adjust thermostat.3. Check the design/unit selection.4. Check and verify the reason (refer to symptom

for "blower works, less air").5. Check the ambient condition.6. Clean it.1. Check for gas leak & charge freon as required.2. Determine the reason and correct it (refer to

symptom for "blower works, less air").3. Clean it.4. Clean it.1. Rectify the reason of low suction pressure (refer

to symptom for "low suction pressure").

1. Shift the location as required.

1. Check freon charge and confirm FLA.2. Check pumpdown solenoid valve operation.

1. Check pumpdown solenoid valve and replace it.

1.Check and correct it properly.2. Check and correct it properly.3. Check and tighten.4. Tighten the pipe support.5. Check the balance, alignment, bracket, etc.

Correct it/replace it.6. Replace the motor.7. Adjust belt tension.8. Align pulley.1. Check and correct it.2. Check and correct it.3. Verify the reason of noisy unit & correct it.4. Verify the design/Relocate the unit if necessary.5. Check & verify the design.6. Remove wooden packing (if any).1. Rectify the reason & correct it.2. Check the compressor amperage each phase.3. Check and correct it.4. Check and verify the reason.5. Check and replace it.6. Check and replace it.7. Check and replace it.1. Check and correct the wiring.2. Check meggar test.3. Check wiring against diagram.4. Replace it, if required.5. Check the circuit breaker ratings.

Unit works continuously, no sufficientcooling

Unit not cooling properly during nighttime

Not sufficiently cooling duringdaytime

Cooling coil ices up

Unit is not restarting (after a cut-off)

Unit is taking long time to restart

Compressor goes lockout (pumpdown system)

Taking more time for the pumpdowncycle, cooling coil ices up

Noisy unit

Unit operational noise listening insidethe building

Compressor not working

Circuit breaker of the unit trips

25

Page 27: PY Installation Manual

26

HEATER CONNECTION DETAILS

(SEE HEATER DATA TABLE)

HEATER DATA TABLE

1.NTB IS APPLICABLE FOR

WIRG. DGM. SUITS

380V/3PH/60Hz UNITS

NOTE380V/3PH/60Hz UNITS

230V/3PH/60HZ 460V/3PH/60HZ &

2. FOR UNITS WITH ABOVEVOLTAGE CONNECT 37A OF FM & L3 OF 1PH BM TO NTB

230V

460V

THERMOSTAT / DDC CONTROLLER

SEE OPTIONAL VFC CONNECTION

J_PROG

TRANS

PRI

12v-0-12v

240v

SEC

FUSE

POWER(GRN)

LIVE

NEUT

RAL

OUTF

AN1

1A1ATB

JP1

TO ATB

JP2 1B

CNC

NO

HP1(HP1)

LP1(LP1)

14

DIP SWITCH

X141

A

LOCK1(RED)

SYSTEM1(YEL)

29HE

ATER

1

HEAT

ER2

30

INFA

N

ECB

P1P2

4A

COMP

13A

230VAC

HC2

HC1

BMC

28

22A23A

CC

LVTB

(SEE NOTE 3)

(SEE NOTE 3)

ATB

L1

TO HVTB

L2/N

(UVM) (SD)

22A23A

LPS

ECB DIP SWITCH SETTINGS & LED INDICATORS

OFF=TEST MODE DISABLE

DIP SWITCH FUCTIONS

LOAD BALANCE

ON= TEST MODE ENABLEsystem 1 fault diagnostic

system lock-out due to system faultpower on/off indicator

S4

FACTORY SETTINGS OF DIP SWITCHES

DIP SWITCH #ON

S1 S2 S3

LED INDICATORS

RedGreen

blinking fast - HPS1 ckt fault blinking slow - LPS1 ckt fault

Set dip switch # 3 according to unit's option(pump down or no pump down)

Yellow

on-board programming function (always set to on)

OFF= WITHOUT PUMP DOWN

OFF=

S4

S3

S1

S2 (Comp1&2 Auto Lead Lag)

ON= WITH PUMP DOWN OPTION

ON= COMPRESSOR 1 LEADOFF

note:

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PY036 - PY075 (Single compressor units)

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items. 2. Refer to unit control box (inside panel) for exact wiring diagram.

Page 28: PY Installation Manual

*

**

FACTORY INSTALLED B.M SPEED*

*

CRANKCASE HEATER CONNECTION

27

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PY036 - PY075 (Single compressor units)

LEGEND

AR AUXILIARY RELAYAFS AIRFLOW SWITCHATB AUXILIARY TERMINAL BLOCKBM BLOWER MOTORBMC BLOWER MOTOR CONTACTORCC COMPRESSOR CONTACTORCB CIRCUIT BREAKERC. HTR CRANKCASE HEATERCOMP COMPRESSORCAP CAPACITORECB ELECTRONIC CONTROL BOARDFL FUSE LINKFM FAN MOTOR (CONDENSER)FMC FAN MOTOR CONTACTORFR FAULT RELAYHC HEATER CONTACTORHPS HIGH PRESSURE SWITCHHVTB HIGH VOLTAGE TERMINAL BLOCKHTR HEATERJP JUMPERL1 LINE 1L2 LINE 2L3 LINE 3LPS LOW PRESSURE SWITCHLUG LUG GROUNDN NEUTRALNTB NEUTRAL TERMINAL BLOCKO/L OVER LOADSD SMOKE DETECTORTRANS TRANSFORMERT'STAT THERMOSTATUVM UNDER VOLTAGE MONITOR

FIELD WIRINGDISCONNECT TAB - 1/4"SPLICE-CLOSED END

_ _ _+

NOTES

1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.

2. ANY WIRE REPLACEMENT SHOULD BE OF 900C OR ITSEQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.

3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASEREAD BROKEN LINES AS CONTINUOUS LINES.

4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FORMINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP.IF POWER IS OFF 6 HOURS OR MORE, CRANKCASEHEATER MUST BE ON FOR 12 HOURS BEFORE OPER-ATING THE SYSTEM.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE-SULT IN COMPRESSOR DAMAGE.

5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKERTO BE PROVIDED BY CONSUMER WITH RATING ASRECOMMENDED BY ZAMIL.

6. COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD.

7. IF ANY CHANGES IN THE DIP SWITCH SETTING IS RE-QUIRED, TURN OFF POWER FIRST & SET REQUIRED SET-TINGS.

C. BM RUN & TRIP INDICATION OPTION

A. UNIT ON INDICATION OPTION

3. VOLT FREE CONTACT OPTIONS

2. SMOKE DETECTOR OPTION

STANDARD OPTIONS1. UVM OPTION

Page 29: PY Installation Manual

28

1.NTB IS APPLICABLE FOR

WIRG. DGM. SUITS

380V/3PH/60Hz UNITS

NOTE

380V/3PH/60Hz UNITS

230V/3PH/60HZ 460V/3PH/60HZ &

(SEE HEATER DATA TABLE)

LUG

HVTB

HEATER DATA TABLE

HEATER CONNECTION DETAILS

TYPE-I TYPE-II

460V

230V

OUTF

AN1

PRI

OUTF

AN2

NEUT

RAL

LIVE

SEC

POWER(GRN)

COMP

1

COMP

2

INFA

N

HEAT

ER1

HEAT

ER2

(LP2)

J_PROG

SYSTEM2(ORG)

LOCK2(RED)

SYSTEM1(YEL)

LOCK1(RED)

(HP2)

(LP1)

LP2

LP1

(HP1)

HP2

HP1

X2 X1 P2 P1

FUSE

DIP SWITCH 23A22A

22B23B

TRANS

240v

12v-0-12v

LVTB

THERMOSTAT / DDC CONTROLLER

CC1

(SEE NOTE 3)

(SEE NOTE 3)28 CNC

NO

CC2

BMC

HC1

JP1ATB 1 JP21A 1B

ATB

HC2

TO ATB

PLEASE REFER TO FAN MOTOR CONTROL CONNECTION FOR T.O.P

SEE OPTIONAL VFC CONNECTION

41B

41A

4B 4A 3A3B30 29 14

ECB

FMC

12

(UVM) (SD)

(SEE NOTE 3)

LPS2

LPS1

26A25A

25B26B

FACTORY SETTINGS OF DIP SWITCHES

ONDIP SWITCH #

OFF

S1 S2 S3 S4

S4

ON= TEST MODE ENABLE

ON= COMPRESSOR 1 LEAD

OFF=TEST MODE DISABLE

LOAD BALANCE S2

S1

(Comp1&2 Auto Lead Lag)OFF=

S3 OFF= WITHOUT PUMP DOWN ON= WITH PUMP DOWN OPTION

on-board programming function (always set to on)

LED INDICATORSGreen power on/off indicatorRed system lock-out due to system fault

Yellowsystem 1 fault diagnostic

blinking slow - LPS1 ckt fault blinking fast - HPS1 ckt fault

Orangesystem 2 fault diagnostic

blinking slow - LPS2 ckt fault

note:Set dip switch # 3 according to unit's option(pump down or no pump down)

ECB DIP SWITCH SETTINGS & LED INDICATORS DIP SWITCH FUCTIONS

TYPICAL SCHEMATIC WIRING DIAGRAM

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items. 2. Refer to unit control box (inside panel) for exact wiring diagram.

MODELS : PY090 - PY150 (Dual compressor units)

Page 30: PY Installation Manual

29

(APPLICABLE FOR FM WITH T.O.P)FAN MOTOR CONTROL CONNECTION

C. BM RUN & TRIP INDICATION OPTION

BM WITH EXTERNAL OLR

CONNECTION APPLICABLE FOR 1PH FM ONLY

1. UVM OPTION

CRANKCASE HEATER CONNECTION

STANDARD OPTIONS

2. SMOKE DETECTOR OPTION

3. VOLT FREE CONTACT OPTIONSA. UNIT ON INDICATION OPTION

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PY090 - PY150 (Dual compressor units)

LEGEND

AR AUXILIARY RELAYAFS AIRFLOW SWITCHATB AUXILIARY TERMINAL BLOCKBM BLOWER MOTORBMC BLOWER MOTOR CONTACTORCC COMPRESSOR CONTACTORCB CIRCUIT BREAKERC. HTR CRANKCASE HEATERCOMP COMPRESSORCAP CAPACITORECB ELECTRONIC CONTROL BOARDFL FUSE LINKFM FAN MOTOR (CONDENSER)FMC FAN MOTOR CONTACTORFR FAULT RELAYHC HEATER CONTACTORHPS HIGH PRESSURE SWITCHHVTB HIGH VOLTAGE TERMINAL BLOCKHTR HEATERJP JUMPERL1 LINE 1L2 LINE 2L3 LINE 3LPS LOW PRESSURE SWITCHLUG LUG GROUNDN NEUTRALNTB NEUTRAL TERMINAL BLOCKO/L OVER LOADSSPS SOLID STATE PROTECTIVE SYSTEMSD SMOKE DETECTORTRANS TRANSFORMERT'STAT THERMOSTATUVM UNDER VOLTAGE MONITORTOP FM THERMAL OVERLOAD PROTECTION

FIELD WIRINGDISCONNECT TAB - 1/4"SPLICE-CLOSED END

_ _ _+

NOTES

1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.

2. ANY WIRE REPLACEMENT SHOULD BE OF 900C OR ITSEQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.

3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASEREAD BROKEN LINES AS CONTINUOUS LINES.

4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FORMINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP.IF POWER IS OFF 6 HOURS OR MORE, CRANKCASEHEATER MUST BE ON FOR 12 HOURS BEFORE OPER-ATING THE SYSTEM.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE-SULT IN COMPRESSOR DAMAGE.

5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKERTO BE PROVIDED BY CONSUMER WITH RATING ASRECOMMENDED BY ZAMIL.

6. COMPRESSORS ARE PROVIDED WITH INTERNAL OVER-LOAD.

7. IF ANY CHANGES IN THE DIP SWITCH SETTING IS RE-QUIRED, TURN OFF POWER FIRST & SET REQUIRED SET-TINGS.

Page 31: PY Installation Manual

30

WIRG. DGM. SUITS

380V/3PH/60Hz UNITS

230V/3PH/60HZ 460V/3PH/60HZ &

WITH MOTOR OVERLOADCONNECTION FOR COMPRESSOR

CONNECTION FOR MANUEROP COMP. WITH SSPS

(SEE HEATER DATA TABLE)HEATER OPTION-1

LUG

HVTB

HEATER OPTION - 2(SEE HEATER DATA TABLE)

380V/3PH/60Hz UNITS1.NTB IS APPLICABLE FOR NOTE

230V

460V

OUTF

AN1

PRI

OUTF

AN2

NEUT

RAL

LIVE

SEC

POWER(GRN)

COMP

1

COMP

2

INFA

N

HEAT

ER1

HEAT

ER2

(LP2)

J_PROG

SYSTEM2(ORG)

LOCK2(RED)

SYSTEM1(YEL)

LOCK1(RED)

(HP2)

(LP1)

LP2

LP1

(HP1)

HP2

HP1

X2 X1 P2 P1

FUSE

DIP SWITCHLPS1

23A22A

22B23B

LPS2

TRANS

240v

12v-0-12v

LVTB

THERMOSTAT / DDC CONTROLLER

CC1

(SEE NOTE 3)

(SEE NOTE 3)28 CNC

NO

CC2

19BMC

HC1

TO HVTB

JP1ATB 1 JP21A 1B

ATB 230VAC

L1 L2/N

HC2

TO ATB

PLEASE REFER TO FAN MOTOR CONTROL CONNECTION FOR OLR, LOW AMBIENT AND T.O.P

SEE OPTIONAL VFC CONNECTION

41B

41A

4B 4A 3A3B30 29 14

ECB

FMC

12

(UVM) (SD)

TYPICAL SCHEMATIC WIRING DIAGRAM

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items. 2. Refer to unit control box (inside panel) for exact wiring diagram.

MODELS : PY180 - PY360 (Dual compressor units)

Page 32: PY Installation Manual

31

C. BM RUN & TRIP INDICATION OPTION

2. SMOKE DETECTOR OPTION

3. VOLT FREE CONTACT OPTIONSA. UNIT ON INDICATION OPTION

B) WITH LOW AMBIENT OPTION

A) STANDARD CONNECTION

(APPLICABLE FOR FM WITH T.O.P)FAN MOTOR CONTROL CONNECTION

LOW AMBIENT OPTION

COMP. WITH CIRCUIT BREAKER OPTION

STANDARD OPTIONS

1. UVM OPTION

LUG

HVTB

TO HVTB

TO HVTB

FACTORY SETTINGS OF DIP SWITCHES

ONDIP SWITCH #

OFF

S1 S2 S3 S4

S4

ON= TEST MODE ENABLE

ON= COMPRESSOR 1 LEAD

OFF=TEST MODE DISABLE

LOAD BALANCE S2

S1

(Comp1&2 Auto Lead Lag)OFF=

S3 OFF= WITHOUT PUMP DOWN ON= WITH PUMP DOWN OPTION

on-board programming function (always set to on)

LED INDICATORSGreen power on/off indicatorRed system lock-out due to system fault

Yellowsystem 1 fault diagnostic

blinking slow - LPS1 ckt fault blinking fast - HPS1 ckt fault

Orangesystem 2 fault diagnostic

blinking slow - LPS2 ckt fault blinking fast - HPS2 ckt fault

note:Set dip switch # 3 according to unit's option(pump down or no pump down)

ECB DIP SWITCH SETTINGS & LED INDICATORS DIP SWITCH FUCTIONS

OUTFAN 1TO ECB

OUTFAN 2TO ECB

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PY180 - PY360 (Dual compressor units)

LEGEND

AR AUXILIARY RELAYAFS AIRFLOW SWITCHATB AUXILIARY TERMINAL BLOCKBM BLOWER MOTORBMC BLOWER MOTOR CONTACTORCC COMPRESSOR CONTACTORCB CIRCUIT BREAKERC. HTR CRANKCASE HEATERCOMP COMPRESSORCAP CAPACITORECB ELECTRONIC CONTROL BOARDFL FUSE LINKFM FAN MOTOR (CONDENSER)FMC FAN MOTOR CONTACTORFR FAULT RELAYHC HEATER CONTACTORHPS HIGH PRESSURE SWITCHHVTB HIGH VOLTAGE TERMINAL BLOCKHTR HEATERJP JUMPERL1 LINE 1L2 LINE 2L3 LINE 3LPS LOW PRESSURE SWITCHLUG LUG GROUNDN NEUTRALNTB NEUTRAL TERMINAL BLOCKO/L OVER LOADSSPS SOLID STATE PROTECTIVE SYSTEMSD SMOKE DETECTORTRANS TRANSFORMERT'STAT THERMOSTATUVM UNDER VOLTAGE MONITORTOP FM THERMAL OVERLOAD PROTECTION

FIELD WIRINGDISCONNECT TAB - 1/4"SPLICE-CLOSED END

_ _ _+

NOTES

1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.

2. ANY WIRE REPLACEMENT SHOULD BE OF 900C OR ITSEQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.

3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASEREAD BROKEN LINES AS CONTINUOUS LINES.

4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FORMINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP.IF POWER IS OFF 6 HOURS OR MORE, CRANKCASEHEATER MUST BE ON FOR 12 HOURS BEFORE OPER-ATING THE SYSTEM.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE-SULT IN COMPRESSOR DAMAGE.

5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKERTO BE PROVIDED BY CONSUMER WITH RATING ASRECOMMENDED BY ZAMIL.

6. COMPRESSORS ARE PROVIDED WITH INTERNAL OVER-LOAD.

7. IF COMPRESSOR IS SUPPLIED WITH SSPS, CONNECT ASSHOWN. PLEASE ALLOW 2-3 MINUTES FOR SSPS SWITCHTO CLOSE, BEFORE STARTING THE UNIT.

8. IF ANY CHANGES IN THE DIP SWITCH SETTING IS RE-QUIRED, TURN OFF POWER FIRST & SET REQUIRED SET-TINGS.

Page 33: PY Installation Manual

32

MODEL NUMBER PY036C PY036H PY036M PY036F PY048C PY048H PY048M PY048FCOMPRESSOR 800-684-01 800-684-04 800-684-14 800-684-07 800-684-03 800-684-06 800-684-09 800-684-09

CONDENSER FAN MOTOR 800-544-02 800-544-02 800-544-02 800-547-32 800-544-02 800-544-02 800-544-02 800-547-32

BLOWER MOTOR 800-547-72 800-547-72 800-547-72 800-547-73 800-546-88 800-546-88 800-546-88 800-546-90

BLOWER WHEEL 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34

CONDENSER FAN PROPELLER 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02

CONTACTOR COMPRESSOR 800-736-07 800-095-01 800-095-01 800-095-01 800-736-22 800-736-22 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27

CAPACITOR FAN MOTOR 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15

AIRFLOW SWITCH 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

CAPILLARY 800-390-45 800-390-45 800-390-45 800-390-45 800-390-33 800-390-33 800-390-33 800-390-33

DISTRIBUTOR 800-198-00 800-198-00 800-198-00 800-198-00 800-191-01 800-191-01 800-191-01 800-191-01

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46

FILTER DRIER 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08

CONTROLLER 80065252 80065252 80065252 80065252 80065252 80065252 80065252 80065252

TRANSFORMER 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

PARTS LIST

MODEL NUMBER PY060H PY060M PY060FCOMPRESSOR 800-672-51 800-672-52 800-672-52

CONDENSER FAN MOTOR 800-544-02 800-544-02 800-547-32

BLOWER MOTOR 800-546-88 800-546-88 800-546-90

BLOWER WHEEL 800-707-34 800-707-34 800-707-34

CONDENSER FAN PROPELLER 800-225-02 800-225-02 800-225-02

CONTACTOR COMPRESSOR 800-736-22 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR 800-736-27 800-736-27 800-736-27

CAPACITOR FAN MOTOR 800-353-15 800-353-15 800-353-15

AIR FLOW SWITCH 800-005-02 800-005-02 800-005-02

CAPILLARY 800-390-37 800-390-37 800-390-37

DISTRIBUTOR 800-191-01 800-191-01 800-191-01

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-46 800-625-46 800-625-46

FILTER DRIER 800-531-08 800-531-08 800-531-08

CONTROLLER 80065252 80065252 80065252

TRANSFORMER 80065253 80065253 80065253

Page 34: PY Installation Manual

33

MODEL NUMBER PY075H PY075M PY075F PY090H PY090M PY090F PY100H PY100M PY100FCOMPRESSOR 800-674-23 800-674-24 800-674-25 800-684-05 800-684-09 800-684-08 800-684-06 800-684-09 800-684-09

CONDENSER FAN MOTOR 800-545-58 800-545-58 800-545-63 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68

BLOWER MOTOR 800-544-13 800-546-44 800-544-13 800-544-16 800-546-29 800-544-16 800-544-16 800-546-29 800-544-16

BLOWER WHEEL 800-707-46 800-707-46 800-707-46 800-707-46 800-707-46 800-707-46 800-707-02 800-707-02 800-707-02

CONDENSER FAN PROPELLER 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23

CONTACTOR COMPRESSOR 800-736-22 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

CONTACTOR COND. FAN MOTOR N.A. N.A. N.A. 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE 800-181-00 800-181-00 800-181-00 800-183-01 800-183-01 800-183-01 800-183-01 800-183-01 800-183-01

DISTRIBUTOR 800-192-03 800-192-03 800-192-03 800-198-02 800-198-02 800-198-02 800-198-02 800-198-02 800-198-02

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29

FILTER DRIER 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08

CONTROLLER 80065252 80065252 80065252 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

PARTS LIST

MODEL NUMBER PY120H PY120M PY120F PY150H PY150M PY150F PY180H PY180M PY180FCOMPRESSOR 800-672-51 800-672-52 800-672-52 800-674-23 800-674-24 800-674-25

CONDENSER FAN MOTOR 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68

BLOWER MOTOR 800-544-17 800-546-92 800-544-17 800-544-17 800-546-92 800-544-17 800-544-72 800-544-64 800-544-72

BLOWER WHEEL 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02

CONDENSER FAN PROPELLER 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23

CONTACTOR COMPRESSOR 800-736-22 800-095-01 800-095-01 800-736-22 800-095-01 800-095-01 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-098-55 800-098-55 800-098-55

CONTACTOR COND. FAN MOTOR 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE 800-181-00 800-181-00 800-181-00 800-181-00 800-181-00 800-181-00 800-182-00 800-182-00 800-182-00

DISTRIBUTOR 800-192-03 800-192-03 800-192-03 800-192-03 800-192-03 800-192-03 800-196-00 800-196-00 800-196-00

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-74 800-625-74 800-625-74

FILTER DRIER 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-05 800-531-05 800-531-05

CONTROLLER 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

800-674-79800-674-76

800-674-80800-674-77

800-674-81800-674-78

800-736-48800-736-22

Page 35: PY Installation Manual

34

MODEL NUMBER PY210H PY210M PY210F PY240H PY240M PY240F PY300H PY300M PY300FCOMPRESSOR 800-674-65 800-674-66 800-674-67 800-674-36 800-674-37 800-674-38 800-674-17 800-674-18 800-674-19

CONDENSER FAN MOTOR 800-545-68 800-545-68 800-545-68 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06

BLOWER MOTOR 800-544-72 800-544-64 800-544-72 800-544-73 800-544-65 800-544-73 800-544-73 800-544-65 800-544-73

BLOWER WHEEL 800-707-02 800-707-02 800-707-02 800-707-23 800-707-23 800-707-23 800-707-23 800-707-23 800-707-23

CONDENSER FAN PROPELLER 800-224-23 800-224-23 800-224-23 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33

CONTACTOR COMPRESSOR 800-736-48 800-736-22 800-095-01 800-736-25 800-736-22 800-736-22 800-736-25 800-736-22 800-736-22

CONTACTOR BLOWER MOTOR 800-098-55 800-098-55 800-098-55 800-098-59 800-098-55 800-098-55 800-098-59 800-098-55 800-098-55

CONTACTOR COND. FAN MOTOR 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE 800-182-00 800-182-00 800-182-00 800-185-00 800-185-00 800-185-00 800-186-00 800-186-00 800-186-00

DISTRIBUTOR 800-196-00 800-196-00 800-196-00 800-194-01 800-194-01 800-194-01 800-192-02 800-192-02 800-192-02

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-74 800-625-74 800-625-74 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38

FILTER DRIER 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05

CONTROLLER 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

PARTS LIST

MODEL NUMBER PY340H PY340M PY340F PY360H PY360M PY360FCOMPRESSOR 800-614-80 800-614-81 800-614-82 800-614-83 800-614-84 800-614-85

CONDENSER FAN MOTOR 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06

BLOWER MOTOR 800-544-73 800-544-65 800-544-73 800-544-74 800-544-66 800-544-74

BLOWER WHEEL 800-707-23 800-707-23 800-707-23 800-707-94 800-707-94 800-707-94

CONDENSER FAN PROPELLER 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33

CONTACTOR COMPRESSOR 800-098-67 800-736-48 800-736-22 800-098-68 800-736-23 800-736-48

CONTACTOR BLOWER MOTOR 800-098-59 800-098-55 800-098-55 800-098-61 800-098-57 800-098-55

CONTACTOR COND. FAN MOTOR 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE 800-186-00 800-186-00 800-186-00 800-186-00 800-186-00 800-186-00

DISTRIBUTOR 800-192-02 800-192-02 800-192-02 800-196-16 800-196-16 800-196-16

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38

FILTER DRIER 800-531-05 800-531-05 800-531-05 800-531-01 800-531-01 800-531-01

CONTROLLER 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER 80065253 80065253 80065253 80065253 80065253 80065253