QAngio ® XA 3D Including Quantitative Flow Ratio (QFR ® ) analysis Physiologic assessment of coronary obstructions Quantitative Flow Ratio (QFR), on-line and on-time Adenosine- and wire-free QFR Pullback curve and Lesion QFR for prioritization in serial lesions Residual Vessel QFR representing the Vessel QFR by exclusion of the target Lesion QFR Accurate 3D measurements for stent sizing Co-registration between 3D QCA and QFR Innovative Acquisition Guide to determine viewing angles for good second projection Physiology: no wire no adenosine

Upload: others

Post on 27-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QAngio XA 3D - Medis Cardiovascular post-processing software · QAngio XA 3D is the analytical software solution for the reconstruction of a coronary artery from two X-ray angiographic

QAngio® XA 3D Including Quantitative Flow Ratio (QFR®) analysis

Physiologic assessment of coronary obstructions

Quantitative Flow Ratio (QFR), on-line and on-time

Adenosine- and wire-free

QFR Pullback curve and Lesion QFR for

prioritization in serial lesions

Residual Vessel QFR representing the Vessel QFR

by exclusion of the target Lesion QFR

Accurate 3D measurements for stent sizing

Co-registration between 3D QCA and QFR

Innovative Acquisition Guide to determine

viewing angles for good second projection

Physiology:

no wire

no adenosine

Page 2: QAngio XA 3D - Medis Cardiovascular post-processing software · QAngio XA 3D is the analytical software solution for the reconstruction of a coronary artery from two X-ray angiographic

Medis Medical Imaging Systems bv

Schuttersveld 9, 2316 XG Leiden

P.O. Box 384, 2300 AJ Leiden, The Netherlands

P +31 71 522 32 44

F +31 71 521 56 17

[email protected]

Medis Medical Imaging Systems, Inc.

9360 Falls of Neuse Road, Suite 103

Raleigh, NC 27615-2484, USA

P +01 (919) 278 7888

F +01 (919) 847 8817

[email protected]

© 2019, Medis medical imaging systems bv

8.13.200.12.2

QAngio XA 3D is the analytical software solution for the reconstruction of a coronary artery from two X-ray angiographic projections at least 25 degrees apart - either from biplane or monoplane X-ray systems - and the subsequent QCA analysis of clinically relevant parameters of coronary obstructions. It is the backbone for subsequent PCI treatment: QAngio XA 3D provides all the anatomical parameters for stent sizing, the optimal viewing angles for visualizing the lesion area, and the physiologic assessment (QFR) of one or more lesions at the same time.

3D QCA analysis • Can be applied to monoplane and biplane

acquisitions

• Accurate offset correction between the projections

• Calibration based on Isocenter data

• Efficient Acquisition Guide suggesting optimal viewing

angles for second acquisition

• Automatic 2D and 3D contour detection and

quantification

• Calculation of optimal viewing angles for

subsequent treatment

• Calculation of lesion foreshortening

• Support for ECG visualization

• Easy wizard for intuitive guided workflows

QFR (Quantitative Flow Ratio) analysis • QFR calculated from 3D QCA according to

different flow models:

- Fixed flow QFR (fQFR), using fixed flow velocity

- Contrast QFR (cQFR), using contrast frame count

in angiogram, without hyperemia

• QFR pullback curve along the analyzed vessel

segment

• Three QFR indices: Vessel, Lesion and Index QFR

• Residual Vessel QFR calculated

Reporting • Detailed and adjustable reporting

• All analysis results can be saved and reloaded again for

reviewing or editing

• Results and screenshots can be exported in numerous

formats (DICOM, xml, pdf, jpg, bmp, png)

Medis, QAngio and QFR are registered trademarks of Medis Associated bv.

QFR is delivered by Medis in a strategic collaboration with Pulse Medical Imaging Technology (Shanghai) Co., Ltd.

QAngio XA 3D is CE-cleared for market in Europe

FDA 510(k) clearance for QAngio XA 3D is pending and therefore the product is currently not available for sale in the US. If you are located in the US and are interested in this package for scientific research purposes, please contact [email protected].